To see the other types of publications on this topic, follow the link: Dental crowns.

Dissertations / Theses on the topic 'Dental crowns'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 50 dissertations / theses for your research on the topic 'Dental crowns.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.

1

Hamsund, Natalie. "Structural integrity of dental crowns." Thesis, KTH, Hållfasthetslära (Inst.), 2014. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-178844.

Full text
Abstract:
There is currently no standardized method for testing dentures made of dental ceramic materials. This creates problems for comparisons between studies concerning strength in materials and geometry. The geometry of the maxillary first premolar was used for the analysis. The modeled crown has two underlying layers, a thin cement layer closest to the crown that attaches the crown to dentin. Simplifications are made so that dentin geometry is modeled in CAD as a cuboid and the cement layer above follow its geometry. For the actual analysis, a FE-analysis has been made of different loading position
APA, Harvard, Vancouver, ISO, and other styles
2

Jager, Nicolaas de. "Design parameters for all-ceramic dental crowns." [S.l : Amsterdam : s.n.] ; Universiteit van Amsterdam [Host], 2004. http://dare.uva.nl/document/87941.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Soonangi, Ganesh Prakruthi. "REVIEW OF DENTAL CROWNS AND THEIR WEAR TESTING." OpenSIUC, 2020. https://opensiuc.lib.siu.edu/theses/2760.

Full text
Abstract:
The desire to replace missing teeth with the aim to improve health and quality of life dates back to a thousand years ago. Although research on dental crown designs, materials and techniques has increased in recent years and is expected to grow in the future. In the past few decades, dental crown studies have gained high importance in dentistry due to their functionality, biocompatibility and good mechanical properties. This paper provides a comprehensive review of history and evolution of dental crowns. The goal of this study is to understand the dental crown materials and the differences in
APA, Harvard, Vancouver, ISO, and other styles
4

Moosa, Rustim. "The effect of dentine-bonding agents on the microleakage of provisional crowns." Thesis, University of the Western Cape, 2005. http://etd.uwc.ac.za/index.php?module=etd&action=viewtitle&id=gen8Srv25Nme4_9061_1181559915.

Full text
Abstract:
<p>The use of provisional acrylic crowns is common practice with prosthodontic treatment. Provisional crowns are prone to marginal leakage and poor retention due to weak interim cements. The aim of this study was to assess the effect of the application of two different dentine-bonding agents on the microleakage of provisional crowns.</p>
APA, Harvard, Vancouver, ISO, and other styles
5

Pihlaja, J. (Juha). "Treatment outcome of zirconia single crowns and fixed dental prostheses." Doctoral thesis, Oulun yliopisto, 2016. http://urn.fi/urn:isbn:9789526212029.

Full text
Abstract:
Abstract Metal ceramic restorations have been used in fixed prosthodontics since the 1950s, but the lack of aesthetics, the inclination to use metal-free materials, possible allergic reactions to metals, and the high cost of high noble alloys have increased the use of all-ceramic materials. The ongoing development of ceramic materials led to the introduction of zirconia to fixed prosthodontics over a decade ago. The mechanical properties of zirconia have proven to be excellent, but the clinical outcome of conventional fixed zirconia restorations over the long term is unclear. This retrospectiv
APA, Harvard, Vancouver, ISO, and other styles
6

Marashdeh, M. M. "Preparations features and periodontal consequences of metal ceramic crowns (MCCs)." Thesis, Queen's University Belfast, 2003. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.273254.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Konkol, Stefan. "The use of composite resins in direct anterior crowns." Thesis, The University of Sydney, 1991. http://hdl.handle.net/2123/4917.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Nawafleh, Noor Ahmed. "Disilicate Crowns in Simulated Oral Environment: The Effect of Tooth Preparation, Crown's Structure and Core/Veneer Thickness Ratio." Thesis, Griffith University, 2016. http://hdl.handle.net/10072/366256.

Full text
Abstract:
Restoring the masticatory function requires a strong restoration which can withstand the masticatory load and survive other challenging conditions in the oral cavity. Historically, several materials were proposed to restore aesthetic and function of the missing teeth such as ivory, bones or even natural teeth obtained from human donors. Since the 1960s, metal ceramic technology has been a very successful application to replace missing tooth/teeth. However, aesthetic and biocompatibility disadvantages of the metal ceramics encouraged the development of strong and competitive metal-free restorat
APA, Harvard, Vancouver, ISO, and other styles
9

Nilsson, Eddie, and Marko Drazic. "Fracture resistance of porcelain-veneered gold-alloy and zirconia molar crowns." Thesis, Malmö högskola, Odontologiska fakulteten (OD), 2013. http://urn.kb.se/resolve?urn=urn:nbn:se:mau:diva-19673.

Full text
Abstract:
AbstraktSyfte:Studiens syfte var att utreda maxlasttoleransen mellan yttria-stabiliserad zirkoniumdioxid- (Y-TZP) och metallkeramiska- (MC) molarkronor med en ny design på in vitro belastningsformen. En stålkula användes för att utöva last på kusparna istället för i fissuren för att framställa en sprickbildning liknande den som ses kliniskt. Materialochmetod:26 kronor tillverkades, varav 13 högädla MC och 13presintrade Y-TZP. 7 av MC göts av 50% tidigare icke-gjuten och 50% omgjuten legering medan de kvarvarande 6 göts av 100% tidigare icke gjuten legering. Kronorna täcktes av ett fasadporsl
APA, Harvard, Vancouver, ISO, and other styles
10

Mahindre, Prajakta Prakash. "Micro-push-out bond strength and the modes of failure for a fiber-reinforced resin-post system cemented using four adhesive luting cements." Click to view the E-thesis via HKUTO, 2009. http://sunzi.lib.hku.hk/hkuto/record/B43224052.

Full text
APA, Harvard, Vancouver, ISO, and other styles
11

Enechi, Theophilus Chukwuemeka. "The taper of clinical crown preparations done by dental students and dentists in two African countries: a comparative analysis." Thesis, University of the Western Cape, 2004. http://etd.uwc.ac.za/index.php?module=etd&amp.

Full text
Abstract:
Crowns have been used since the 5th century AD to improve both the form and function of teeth in the mouth. A great proportion of the total expenditure on dental care is spent on the provision and replacement of crowns and bridges and the number is increasing every year. A full coverage crown is a restoration placed over a single prepared tooth or it acts as an abutment in a bridge for the restoration of a missing tooth or teeth. Crowns are considered successful only when they meet both the aesthetic and functional requirements of the patient. For these to be met, certain principles for the pr
APA, Harvard, Vancouver, ISO, and other styles
12

Silva, Camila Perfeito Evangelista da. "Effect of CAD/CAM abutment height and cement type on the retention of zirconia crowns." Universidade de São Paulo, 2018. http://www.teses.usp.br/teses/disponiveis/25/25146/tde-31082018-144600/.

Full text
Abstract:
Aim: To evaluate the effect of different Ti-base abutment heights and cement type on the pullout retention of zirconia-based restorations. Methods: Identical crowns were designed in a CAD software to fit two different Tibase abutment heights, as follows (n=10/group): (i) 4-mm-height Ti-base abutment (Tall), and (ii) 2.5-mm-height Ti-base abutment (Short). Four cement types were selected: (i) Temporary cement (Provisional); (ii) Glass-ionomer cement (Meron); (iii) self-adhesive resin cement (U200), and (iv) conventional resin cement (Ultimate) with universal adhesive for treatment of titanium a
APA, Harvard, Vancouver, ISO, and other styles
13

Mikeli, Aikaterini. "Porcelain fractures in implant borne fixed dental prostheses and single crowns A retrospective clinical study." Doctoral thesis, Saechsische Landesbibliothek- Staats- und Universitaetsbibliothek Dresden, 2015. http://nbn-resolving.de/urn:nbn:de:bsz:14-qucosa-153594.

Full text
Abstract:
Introduction: Porcelain fractures belong to the most frequent technical complications in implant borne fixed restorations. Aim of this retrospective clinical study was to determine the prevalence and extent of porcelain fractures and to detect possible risk indicators. Methods: The study was designed by the Department of Prosthetic Dentistry, Dental School, University Hospital Carl Gustav Carus of Technical University of Dresden (TUD). Only adult patients (age ≥ 18 years) having previously received implant borne either metal-ceramic or all-ceramic fixed dental restorations from January 1995 un
APA, Harvard, Vancouver, ISO, and other styles
14

Overturf, Jan Hendrik. "The effects of diferent reinforcements on the fracture toughness of provisional restorative materials." Thesis, University of the Western Cape, 2006. http://etd.uwc.ac.za/index.php?module=etd&action=viewtitle&id=gen8Srv25Nme4_2033_1254998751.

Full text
Abstract:
<p>One of the most critical aspects of successful crown and bridgework is temporary restorations. Failure of temporary restoratins often affects the patient's confidence and mau result in unscheduled appointments for repair. This study compared the the fracture toughness of two materials commonly used to fabricate provisional restorations, namely Coldpac, a polymethyl methacrylate and Protemp 3 Garant, a bis-acryl composite. It also compard the fracture toughness of the two materials when reinforced with stainless steel wire, glass fibers and polythylene fibers.</p>
APA, Harvard, Vancouver, ISO, and other styles
15

Fokkinga, Wietske Anke. "Post it? Reconstruction of the endodontically treated tooth /." Nijmegen, the Netherlands : Radboud University Nijmegen, 2007. http://webdoc.ubn.ru.nl/mono/f/fokkinga_w/postit.pdf.

Full text
APA, Harvard, Vancouver, ISO, and other styles
16

Fardin, Vinícius Pavesi. "A avaliação da confiabilidade e modo de falha de coroas de sistemas cerâmicos em função do desenho da infraestrutura e da aplicação de carga em cristas marginais." Universidade de São Paulo, 2013. http://www.teses.usp.br/teses/disponiveis/25/25146/tde-14082013-092548/.

Full text
Abstract:
As excelentes propriedades mecânicas da zircônia fazem com que ela seja o material cerâmico de eleição para as coroas e próteses fixas posteriores. Porém, os problemas relacionados à fratura ainda persistem. A falta de suporte das infraestruturas às cerâmicas de revestimento é indicada como uma possível causa. O presente estudo visou avaliar através de testes laboratoriais se as infraestruturas metálicas e cerâmicas com o desenho convencional ou modificado apresentam diferença estatisticamente significante quanto à redução de complicações mecânicas, como fraturas e trincas na cerâmica de reves
APA, Harvard, Vancouver, ISO, and other styles
17

Carmichael, Lonny Dale. "Esthetic Posterior Stainless Steel Crowns and their Relative Shear Strengths." VCU Scholars Compass, 2008. http://scholarscompass.vcu.edu/etd/937.

Full text
Abstract:
Purpose: The purpose of this study was to evaluate esthetic posterior stainless steel crowns (EP-SSC) and compare their relative shear strengths.Methods: Sixty EP-SSC were compared. 15 crowns from NuSmile® Primary Crowns, Kinder Krowns, and Dental Innovators 1UP and EC Crowns were studied. The crowns were cemented to a typodont tooth then thermally cycled in water baths to simulate oral conditions. Shear strengths were evaluated by subjecting these crowns to simulated forces of occlusion.Results: The force required to cause shearing of the esthetic facings was statistically significant.
APA, Harvard, Vancouver, ISO, and other styles
18

Ironside, James G. "An In Vitro Analysis Of The Behaviour Of An Alumina Based Dental All-Ceramic Restorative System Subjected To Occlusal Loads." Thesis, The University of Sydney, 2001. http://hdl.handle.net/2123/4850.

Full text
Abstract:
Doctor of Philosophy<br>The commercial introduction of glass infiltrated slip cast ceramic technology as a core dental ceramic for crowns and bridges began in 1990. The system known as Inceram® provided a metal free ceramic core with a flexural strength that was reported to be between 400 and 600 MPa. The first aim of this study was to investigate in vitro fractures for this type of crown that occurred from high localized occlusal loading. The second aim was to propose suitable guidelines for the construction of crowns that are more crack resistant when loaded by a spherical object such as an
APA, Harvard, Vancouver, ISO, and other styles
19

Ironside, James G. "An in vitro analysis of the behaviour of an alumina based dental all-ceramic restorative system subjected to occlusal loads." University of Sydney, 2001. http://hdl.handle.net/2123/4254.

Full text
Abstract:
Doctor of Philosophy<br>The commercial introduction of glass infiltrated slip cast ceramic technology as a core dental ceramic for crowns and bridges began in 1990. The system known as Inceram® provided a metal free ceramic core with a flexural strength that was reported to be between 400 and 600 MPa. The first aim of this study was to investigate in vitro fractures for this type of crown that occurred from high localized occlusal loading. The second aim was to propose suitable guidelines for the construction of crowns that are more crack resistant when loaded by a spherical object such as an
APA, Harvard, Vancouver, ISO, and other styles
20

Low, Chun Yu Danny. "Prediction of the dimensional accuracy of small extra-coronal titanium castings." University of Sydney, 1998. http://hdl.handle.net/2123/4655.

Full text
Abstract:
Master of Science in Dentistry<br>This work was digitised and made available on open access by the University of Sydney, Faculty of Dentistry and Sydney eScholarship . It may only be used for the purposes of research and study. Where possible, the Faculty will try to notify the author of this work. If you have any inquiries or issues regarding this work being made available please contact the Sydney eScholarship Repository Coordinator - ses@library.usyd.edu.au
APA, Harvard, Vancouver, ISO, and other styles
21

Harrington, Pamela P. "Post retention with mineral trioxide aggregate and accelerated Portland cement." Morgantown, W. Va. : [West Virginia University Libraries], 2005. https://etd.wvu.edu/etd/controller.jsp?moduleName=documentdata&jsp%5FetdId=4035.

Full text
Abstract:
Thesis (M.S.)--West Virginia University, 2005.<br>Title from document title page. Document formatted into pages; contains viii, 57 p. : ill. (some col.). Vita. Includes abstract. Includes bibliographical references (p. 34-39).
APA, Harvard, Vancouver, ISO, and other styles
22

Matracia, Yoon-Mi(Sophie) L. "Pulpotomy to Stainless Steel Crown Ratio in Children with Early Childhood Caries: A Cross Sectional Analysis." Columbus, Ohio : Ohio State University, 2009. http://rave.ohiolink.edu/etdc/view?acc%5Fnum=osu1242096142.

Full text
APA, Harvard, Vancouver, ISO, and other styles
23

Mahindre, Prajakta Prakash. "Micro-push-out bond strength and the modes of failure for a fiber-reinforced resin-post system cemented using four adhesive lutingcements." Thesis, The University of Hong Kong (Pokfulam, Hong Kong), 2009. http://hub.hku.hk/bib/B43224052.

Full text
APA, Harvard, Vancouver, ISO, and other styles
24

Salaita, Louai Ghaleb. "Strain analysis and fracture strength of different abutments for cement-retained crowns on an internal hexagon implant." The Ohio State University, 2014. http://rave.ohiolink.edu/etdc/view?acc_num=osu1404820351.

Full text
APA, Harvard, Vancouver, ISO, and other styles
25

Lameira, Deborah Pacheco 1982. "Fracture strength of monolithic and bi-layer zirconia-based crowns = Resistência à fratura de coroas monolíticas e bicamada a base de zircônia." [s.n.], 2014. http://repositorio.unicamp.br/jspui/handle/REPOSIP/290241.

Full text
Abstract:
Orientador: Wilkens Aurelio Buarque e Silva<br>Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba<br>Made available in DSpace on 2018-08-24T18:40:10Z (GMT). No. of bitstreams: 1 Lameira_DeborahPacheco_D.pdf: 11244410 bytes, checksum: 54506eb4da406d4e27116632cc014de5 (MD5) Previous issue date: 2014<br>Resumo: O objetivo deste estudo foi avaliar a resistência à fratura de coroas monolíticas e bicamada a base de zircônia, após envelhecimento artificial. Para este estudo, foram utilizados 32 incisivos bovinos onde foram feitos preparos de coroa total. Es
APA, Harvard, Vancouver, ISO, and other styles
26

Prates, Luiz Henrique Maykot. "Influencia de agentes cimentantes na resistencia a tração de coroas totais fundidas, fixadas em dentina e nucleos metalicos." [s.n.], 1999. http://repositorio.unicamp.br/jspui/handle/REPOSIP/290096.

Full text
Abstract:
Orientador: Simonides Consani<br>Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba<br>Made available in DSpace on 2018-07-25T17:22:10Z (GMT). No. of bitstreams: 1 Prates_LuizHenriqueMaykot_M.pdf: 4937964 bytes, checksum: 1759111268df7345a8f2609a47b24c1d (MD5) Previous issue date: 1999<br>Resumo: O propósito do estudo foi avaliar o comportamento de 4 agentes cimentantes, em relação à resistência à remoção, por tração, de coroas totais fundidas, fixadas sobre preparos em dentina e núcleos metálicos. Foram utilizados 28 molares humanos, inferiore
APA, Harvard, Vancouver, ISO, and other styles
27

Buranadham, Supanee. "Dowel design optimization in an endodontically treated single-rooted tooth a finite element stress analysis /." Diss., University of Iowa, 2000. http://ir.uiowa.edu/etd/191.

Full text
Abstract:
Thesis (Ph. D.)--University of Iowa, 2000.<br>Supervisor: Clark M. Stanford. Title-page, preliminaries, Certificate of approval, Table of contents and Project summary issued in paper (xii, 13 leaves ; 28 cm.). Includes bibliographical references. Also issued on CD-ROM (144 files, 33.7 megabytes).
APA, Harvard, Vancouver, ISO, and other styles
28

Lorenzoni, Fabio Cesar. "Avaliação da confiabilidade e modo de falha de coroas cerâmicas em função do módulo de elasticidade dos endentadores." Universidade de São Paulo, 2013. http://www.teses.usp.br/teses/disponiveis/25/25146/tde-15102013-085230/.

Full text
Abstract:
A incompatibilidade entre o módulo de elasticidade (E) do endentador e dos materiais cerâmicos durante os testes de fadiga tem gerado controvérsias. Foram testadas as hipóteses que coroas totalmente cerâmicas apresentarão confiabilidade à fadiga acelerada progressiva do tipo step-stress (hipótese 1) e modos de falha (hipótese 2) similares, quando dois endentadores, um à base de carboneto de tungstênio (WC, E = 600 GPa) e outro de cerâmica esteatite [SB, E = 90 GPa] forem utilizados para transferir a carga. Para avaliar o efeito dos endentadores, um preparo para coroa total em um molar infer
APA, Harvard, Vancouver, ISO, and other styles
29

Ironside, James G. "An in vitro analysis of the behaviour of an alumina based dental all-ceramic restorative system subjected to occlusal loads." Thesis, The University of Sydney, 2001. http://hdl.handle.net/2123/4254.

Full text
Abstract:
The commercial introduction of glass infiltrated slip cast ceramic technology as a core dental ceramic for crowns and bridges began in 1990. The system known as Inceram® provided a metal free ceramic core with a flexural strength that was reported to be between 400 and 600 MPa. The first aim of this study was to investigate in vitro fractures for this type of crown that occurred from high localized occlusal loading. The second aim was to propose suitable guidelines for the construction of crowns that are more crack resistant when loaded by a spherical object such as an opposinc cusp. The revie
APA, Harvard, Vancouver, ISO, and other styles
30

Holland, Martha M. "A Comparison of Treatment Planning Modalities for the Pediatric Dental Patient." VCU Scholars Compass, 2017. http://scholarscompass.vcu.edu/etd/4750.

Full text
Abstract:
Purpose: To assess the treatment modalities of pediatric dentists for restoring Class II lesions in primary molars. Methods: A survey of eight cases was emailed to AAPD members, who were asked to choose a stainless steel crown (SSC) or composite resin. Treatment choice was associated with provider type, years in practice, behavior management, lesion detection, and patient age. Results: Clinically detectable caries restored under general anesthesia were treated more often with a SSC. Faculty and residents chose a SSC at a greater rate. Providers with 10 or more years experience chose a SSC more
APA, Harvard, Vancouver, ISO, and other styles
31

Sicoli, Eliseu Augusto 1960. "Influência da concentração do ácido hidrofluorídrico e da ciclagem térmica na resistência da união entre cerâmica e cimento resinoso." [s.n.], 2011. http://repositorio.unicamp.br/jspui/handle/REPOSIP/290059.

Full text
Abstract:
Orientador: Simonides Consani<br>Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba<br>Made available in DSpace on 2018-08-18T17:46:05Z (GMT). No. of bitstreams: 1 Sicoli_EliseuAugusto_D.pdf: 4658696 bytes, checksum: ce260af08392da02937030d7837080d4 (MD5) Previous issue date: 2011<br>Resumo: O objetivo neste estudo foi avaliar o efeito do condicionamento com ácido hidrofluorídrico ( 5 e 10%) e ciclagem térmica na resistência ao microcisalhamento da interface cimento resinoso RelyX ARC - IPS E.max Press. Foram confeccionadas 20 amostras com cerâmica I
APA, Harvard, Vancouver, ISO, and other styles
32

Azevedo, Fabiola Pontes. "Incidência de fraturas em próteses fixas: estudo retrospectivo. Análise da sobrevivência de próteses metalocerâmicas após um período mínimo de quatro anos em função." Universidade de São Paulo, 2017. http://www.teses.usp.br/teses/disponiveis/25/25146/tde-20022018-151400/.

Full text
Abstract:
As próteses metalocerâmicas ainda são apontadas como o tratamento de escolha em reabilitação oral por apresentarem altas taxas de sobrevivência, mesmo que o fator estético possa ser comprometido devido às propriedades óticas relacionadas à infraestrutura metálica. Além disso, há pouca informação na literatura científica sobre os fatores que levam às fraturas das próteses fixas metalocerâmicas. Com isso, o presente estudo teve como objetivo avaliar se a quantidade de elementos que compõe uma prótese, se a quantidade de elementos por retentor, se o tipo de prótese, se o tipo de pilar, se a local
APA, Harvard, Vancouver, ISO, and other styles
33

Mobilio, Nicola. "The use of lithium disilicate in fixed dental prosthesis: from the adhesive interface to clinical performance." Doctoral thesis, Università di Siena, 2019. http://hdl.handle.net/11365/1071540.

Full text
Abstract:
Chapter 1 is an introduction to lithium disilicate: its glass ceramic nature, its characteristics, its mechanical properties. The possibility to be etched allows lithium disilicate to be adhesively luted on dental tissues, influencing both the final properties of restoration and the clinical protocol of cementation. The aim of this thesis was investigate the adhesive interface between lithium disilicate, resin cement and dental tissues from different points of view: retention, fracture strength and survival rate. In Chapter 2 the retention of lithium disilicate crowns cemented using two diffe
APA, Harvard, Vancouver, ISO, and other styles
34

Jóias, Renata Pilli. "FATORES RELACIONADOS À PROPORÇÃO DENTAL ANTERIOR DE BOLTON EM INDIVÍDUOS COM OCLUSÃO NORMAL NATURAL." Universidade Metodista de São Paulo, 2010. http://tede.metodista.br/jspui/handle/tede/1278.

Full text
Abstract:
Made available in DSpace on 2016-08-03T16:31:15Z (GMT). No. of bitstreams: 1 Paginas 1-43.pdf: 4925935 bytes, checksum: 290160b606f5978346daa511574f6a06 (MD5) Previous issue date: 2010-03-25<br>The Bolton anterior ratio should be considered in the orthodontic planning in order to excellent occlusion achievement. The aim of this study was to verify wether some factors could be related to Bolton s anterior ratio: upper incisors buccolingual thickness, upper incisors mesiodistal tipping, overjet and overbite, and if there is sexual dimorfism. Thirty-five pairs of dental casts with natural norma
APA, Harvard, Vancouver, ISO, and other styles
35

Fonseca, Renata Garcia [UNESP]. "Avaliação da resistência à remoção por tração de coroas metálicas fixadas com cimentos resinosos e da dureza desses materiais em função do método de ativação." Universidade Estadual Paulista (UNESP), 2001. http://hdl.handle.net/11449/105515.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2001-10-01Bitstream added on 2014-06-13T20:25:47Z : No. of bitstreams: 1 fonseca_rg_dr_arafo.pdf: 347306 bytes, checksum: 7bab875463a1706adf2e01435b649315 (MD5)<br>Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)<br>Foram avaliados grau de polimerização de cimentos resinosos em função de diferentes intensidades de luz, por meio de ensaio de dureza, e resistência à remoção por tração de coroas cimentadas em troquéis com determinados cimentos. A primeira etapa foi realizada submetendo
APA, Harvard, Vancouver, ISO, and other styles
36

Carvalho, Breno Carnevalli Franco de 1963. "Análise fotoelástica da distribuição de tensões geradas por carregamento em coroas unitárias suportadas por implantes curto e longo." [s.n.], 2013. http://repositorio.unicamp.br/jspui/handle/REPOSIP/288566.

Full text
Abstract:
Orientador: Rafael Leonardo Xediek Consani<br>Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba<br>Made available in DSpace on 2018-08-24T03:25:43Z (GMT). No. of bitstreams: 1 Carvalho_BrenoCarnevalliFrancode_D.pdf: 2254429 bytes, checksum: 0864903c9e5a5e409b843fd792284ecc (MD5) Previous issue date: 2013<br>Resumo: Implantes curtos são utilizados em situações clínicas quando a altura e/ou a espessura óssea são insuficientes. A proposta neste estudo foi verificar por meio da análise de tensão fotoelástica a influência exercida pela altura e largura d
APA, Harvard, Vancouver, ISO, and other styles
37

Zabel, Melanie, and Nataša Vasiljević. "Anterior single crown treatments made by dental students and teachers at Malmö University, Sweden; a 5-year retrospective follow-up." Thesis, Malmö universitet, Odontologiska fakulteten (OD), 2021. http://urn.kb.se/resolve?urn=urn:nbn:se:mau:diva-42293.

Full text
Abstract:
Aim: To investigate the clinical survival and success, including both function and aesthetics, of tooth supported crowns in the anterior region after a minimum of 5 years after installation in the student as well as teacher clinic of the Faculty of Odontology, Malm. University, Sweden. Materials &amp; method: Eligible patients were identified through screening of dental technician invoices stretching back to 2012. 78 patients were invited to participate in the study and 39 patients were examined, 28 and 11 from student and teacher clinics respectively. A modified examination protocol based on
APA, Harvard, Vancouver, ISO, and other styles
38

Lorenzoni, Fabio Cesar. "Avaliação do modo de falha de coroas cerâmicas com e sem alteração do desenho das infraestruturas." Universidade de São Paulo, 2009. http://www.teses.usp.br/teses/disponiveis/25/25135/tde-28052009-142343/.

Full text
Abstract:
Coroas cerâmicas têm sido amplamente utilizadas, entretanto, problemas relacionados com a fratura destes materiais persistem principalmente nos sistemas ceramocerâmicos na região de molar. As hipóteses nulas testadas foram que o desenho da infraestrutura e o tipo de material não terão efeito significante na resistência à fadiga. Coroas metalocerâmicas e ceramocerâmicas foram fabricadas sobre o preparo de um molar superior, o qual reproduzia a complexa morfologia dos preparos dentários. Quatro grupos foram estabelecidos (n=10 por grupo) baseados no desenho das infraestruturas (padrão ou alterad
APA, Harvard, Vancouver, ISO, and other styles
39

Rezende, Carlos Eduardo Edwards. "Influência da contração de sinterização na adaptação de copings de Y-TZP: Efeito na distribuição de tensões." Universidade de São Paulo, 2015. http://www.teses.usp.br/teses/disponiveis/25/25146/tde-03022016-144333/.

Full text
Abstract:
A longevidade das coroas cerâmicas depende, entre outros fatores, de sua adaptação ao pilar, bem como da distribuição das tensões nas mesmas. Não há um consenso sobre a melhor adaptação dos copings de zircônia feitos em CAD/CAM em relação aos métodos convencionais, podendo haver uma influência da contração de sinterização sobre esta. O presente estudo avaliou as alterações dimensionais decorrentes do processo de sinterização em três diferentes marcas comerciais de blocos de zircônia, relacionando-as com a adaptação de copings confeccionados por um sistema CAD/CAM, além de avaliar como a adapta
APA, Harvard, Vancouver, ISO, and other styles
40

Forberger, Virag Nicole. "Influence of the type of post and core on in vitro marginal continuity, fracture resistance, and fracture mode of lithia disilicate-based all-ceramic crowns /." [S.l.] : [s.n.], 2009. http://opac.nebis.ch/cgi-bin/showAbstract.pl?sys=000278509.

Full text
APA, Harvard, Vancouver, ISO, and other styles
41

Moreira, Marlene Tavares. "Avaliação dos tipos de reabilitações fixas dento-suportadas em dentes anteriores." Master's thesis, [s.n.], 2013. http://hdl.handle.net/10284/4449.

Full text
Abstract:
Projeto de Pós-Graduação/Dissertação apresentado à Universidade Fernando Pessoa como parte dos requisitos para obtenção do grau de Mestre em Medicina Dentária<br>Introdução: O conhecimento das características das próteses fixas metalocerâmicas e totalmente cerâmicas é fundamental para se obter uma reabilitação oral adequada, tanto para o médico-dentista como para o paciente a ser reabilitado. Na literatura científica estão descritas diversas possibilidades de tratamento e existe uma grande variabilidade de materiais e protocolos instituídos, o que dificulta a comparação e a conclusão relativa
APA, Harvard, Vancouver, ISO, and other styles
42

Dal, Piva Amanda Maria de Oliveira. "Influência da espessura da cerâmica no comportamento biomecânico, sobrevivência e na translucidez de coroas monolíticas /." São José dos Campos, 2020. http://hdl.handle.net/11449/192601.

Full text
Abstract:
Orientador: Marco Antonio [Unesp] Bottino<br>Resumo: Apesar do aumento do uso de coroas monolíticas, seu desempenho, em diferentes aspectos, ainda não foi determinado. Inicialmente, este projeto investigou o comportamento biomecânico de diferentes coroas monolíticas convencionais sobre dentes e a distribuição de tensões na camada de cimento (Artigo 1). Como objetivo principal, este estudo avaliou o efeito do princípio do mínimo preparo dental no comportamento biomecânico, confiabilidade e translucidez de coroas monolíticas posteriores em cerâmica. No entanto, para definir o substrato a ser uti
APA, Harvard, Vancouver, ISO, and other styles
43

Mikeli, Aikaterini [Verfasser], Michael [Akademischer Betreuer] Walter, and Günter [Akademischer Betreuer] Lauer. "Porcelain fractures in implant borne fixed dental prostheses and single crowns A retrospective clinical study / Aikaterini Mikeli. Gutachter: Michael Walter ; Günter Lauer. Betreuer: Michael Walter." Dresden : Saechsische Landesbibliothek- Staats- und Universitaetsbibliothek Dresden, 2015. http://d-nb.info/1069040525/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
44

Mikeli, Aikaterini Verfasser], Michael [Akademischer Betreuer] Walter, and Günter [Akademischer Betreuer] [Lauer. "Porcelain fractures in implant borne fixed dental prostheses and single crowns A retrospective clinical study / Aikaterini Mikeli. Gutachter: Michael Walter ; Günter Lauer. Betreuer: Michael Walter." Dresden : Saechsische Landesbibliothek- Staats- und Universitaetsbibliothek Dresden, 2015. http://d-nb.info/1069040525/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
45

Bergamo, Edmara Tatiely Pedroso 1985. "Fracture load and phase transformation in monolithic zirconia crowns submitted to hydrothermal or mechanical treatments = Carga à fratura e transformação de fase em coroas monolíticas de zircônia submetidas a envelhecimento hidrotérmico ou mecânico." [s.n.], 2015. http://repositorio.unicamp.br/jspui/handle/REPOSIP/290235.

Full text
Abstract:
Orientadores: Wander José da Silva, Altair Antoninha Del Bel Cury<br>Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba<br>Made available in DSpace on 2018-08-27T01:05:41Z (GMT). No. of bitstreams: 1 Bergamo_EdmaraTatielyPedroso_M.pdf: 7968983 bytes, checksum: ebd79c42e62e1085b97f070b982adcce (MD5) Previous issue date: 2015<br>Resumo: Os sistemas cerâmicos representam na odontologia uma alternativa aos metais na reabilitação protética, sendo que a zircônia é o material com melhores propriedades mecânicas. Coroas confeccionadas em zircônia sem a
APA, Harvard, Vancouver, ISO, and other styles
46

Fonseca, Renata Garcia. "Avaliação da resistência à remoção por tração de coroas metálicas fixadas com cimentos resinosos e da dureza desses materiais em função do método de ativação /." Araraquara : [s.n.], 2001. http://hdl.handle.net/11449/105515.

Full text
Abstract:
Orientador: Carlos Alberto dos Santos Cruz<br>Banca: Gelson Luis Adabo<br>Banca: Luís Geraldo Vaz<br>Banca: Rosehelene Marotta Araújo<br>Banca: Adriana Cristina Zavanelli<br>Resumo: Foram avaliados grau de polimerização de cimentos resinosos em função de diferentes intensidades de luz, por meio de ensaio de dureza, e resistência à remoção por tração de coroas cimentadas em troquéis com determinados cimentos. A primeira etapa foi realizada submetendo-se ou não os cimentos resinosos Panavia F, Scothbond Resin Cement, Enforce e Cement-It à fotoativação, tendo as leituras sido realizadas nos tempo
APA, Harvard, Vancouver, ISO, and other styles
47

Zegarra, Cavero-Blumenfeld Fernanda, and Huamán Katya Valeria Meza. "Comparación in vitro de la adaptación marginal de coronas unitarias de porcelana vitrocerámica elaboradas con tres sistemas de procesado." Bachelor's thesis, Universidad Peruana de Ciencias Aplicadas (UPC), 2020. http://hdl.handle.net/10757/653925.

Full text
Abstract:
Objetivo: Comparar in vitro la adaptación marginal de coronas unitarias de porcelana vitrocerámica elaboradas con tres sistemas de procesado. Materiales y métodos: El presente estudio fue de tipo experimental in vitro. La muestra estuvo conformada por 69 coronas de porcelana vitrocerámica fabricadas con los sistemas: CAD-CAM, inyección de porcelana y condensación sobre muñón refractario. Para la evaluación de la discrepancia marginal vertical se realizó un registro fotográfico con una cámara digital y un lente macroscópico de 100 milímetros. Las imágenes fueron medidas digitalmente (ImageJ
APA, Harvard, Vancouver, ISO, and other styles
48

De, Villa Camargos Germana 1987. "Influência dos fatores biomecânicos associados às reabilitações unitárias implanto-suportadas e da condição óssea sobre a estrutura e comportamento biomecânico do tecido ósseo = Influence of biomechanical factors associated to implant-supported single crowns and of the bone condition on the bone structure and biomechanical behavior." [s.n.], 2015. http://repositorio.unicamp.br/jspui/handle/REPOSIP/287957.

Full text
Abstract:
Orientador: Altair Antoninha Del Bel Cury<br>Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba<br>Made available in DSpace on 2018-08-26T17:31:59Z (GMT). No. of bitstreams: 1 DeVillaCamargos_Germana_D.pdf: 53591666 bytes, checksum: 7903be28cac8e5312c36fb24f0e3bb96 (MD5) Previous issue date: 2015<br>Resumo: Considerando o impacto do ambiente biomecânico e da condição óssea sobre o prognóstico da terapia com implantes dentais, esse trabalho teve como objetivos (1) avaliar a influência do tipo dos pilares protéticos utilizados nas próteses unitárias pa
APA, Harvard, Vancouver, ISO, and other styles
49

Caiado, Ana Carolina Rocha Lima. "Resistencia de união e caracterização morfologica da dentina coronaria e radicular tratada com sistemas adesivos." [s.n.], 2006. http://repositorio.unicamp.br/jspui/handle/REPOSIP/288182.

Full text
Abstract:
Orientador: Mario Fernando de Goes<br>Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba<br>Made available in DSpace on 2018-08-08T13:06:43Z (GMT). No. of bitstreams: 1 Caiado_AnaCarolinaRochaLima_M.pdf: 12410221 bytes, checksum: 10dff9d1f7b58797480e9a00a97d0a78 (MD5) Previous issue date: 2006<br>Resumo: Este estudo teve como objetivos: (a) caracterizar a morfologia, a densidade e a área transversal de túbulos dentinários da dentina coronária (profunda) e radicular (terço cervical) intactas e após condicionamento com ácido fosfórico 32%
APA, Harvard, Vancouver, ISO, and other styles
50

Alayan, Jamil. "Maxillary Sinus Augmentation - a histological, clinical, radiographic and patient centred assessment." Thesis, Griffith University, 2018. http://hdl.handle.net/10072/381656.

Full text
Abstract:
Maxillary sinus pneumatization is a frequently encountered problem in the dental implant rehabilitation of the posterior maxilla. Maxillary sinus augmentation (MSA) using a lateral wall approach is a well-established and commonly utilized surgical technique for overcoming this bone deficiency and allowing implant placement. MSA is still in the refinement process with a large degree of variation in all aspects of the technique including; the surgical protocol, the anatomical site, the choice of material, the site of autogenous bone harvesting, the timing of implant surgery and the use of barrie
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!