To see the other types of publications on this topic, follow the link: Mikrofluidika.

Dissertations / Theses on the topic 'Mikrofluidika'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 50 dissertations / theses for your research on the topic 'Mikrofluidika.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.

1

Bohunský, Tomáš. "Kavitace na mikrofluidické clonce." Master's thesis, Vysoké učení technické v Brně. Fakulta strojního inženýrství, 2021. http://www.nusl.cz/ntk/nusl-444292.

Full text
Abstract:
This diploma thesis deals with cavitation flow in the microscale, which remains an area with a lack of sufficient description of this phenomenon. At the same time, microfluidics is a field experiencing a dramatic rise in numerous biochemical applications, which underlines the relevance of researches of this type. In theoretical part of the thesis, cavitation was described in detail. In the practical part, a microfluidic device with a cavitation orifice was designed and manufactured. The ANSYS program was used for this design. An experiment was performed with the designed microchip, the aim of which was to observe a cavitating flow on the orifice. This measurement took place at the microfluidic laboratory at Victor Kaplan Department of Fluid Engineering. Due to the failure of the experiment, a CFD model of two-phase cavitation flow was built. The conclusions of the thesis were compiled from the findings of measurement and the results of modeling.
APA, Harvard, Vancouver, ISO, and other styles
2

Königsmarková, Kristýna. "Mikrofluidický enzymatický reaktor pro testování léčiv." Master's thesis, Vysoké učení technické v Brně. Fakulta chemická, 2019. http://www.nusl.cz/ntk/nusl-401925.

Full text
Abstract:
This master thesis deals with the use of microfluidics for the purpose of microfluidic enzymatic reactor for drug screening. At first it considers the issue from a theoretical point of view – describes microfluidics as a newly developing and promising field of production of microfluidic devices, materials, biomedical applications and advantages and disadvantages of microfluidics overall. Furthermore, it focuses on an area of analytical utilization of enzymes within enzyme reactors. In the first part of the experimental section, conditions for the testing of enzymes of xenobiotics metabolism in the liver were optimized, namely the model of coumarin metabolism via the spectrofluorimetry method. The second part of the experimental work dealt with optimization of the fabrication conditions of microfluidic chips from OSTE (off-stoichiometry Thiol Ene) via the soft lithography method. Subsequently, the functionality of the produced chips was tested. Based on the results of both parts of the experimental work, an evaluation was carried out to assess the suitability of their interconnection for future research – screening of microsomal enzyme activity and model biotransformation of drugs within the channels of the fabricated devices.
APA, Harvard, Vancouver, ISO, and other styles
3

Stehlík, Martin. "Modelování dvoufázového proudění bublin v mikrofluidice." Master's thesis, Vysoké učení technické v Brně. Fakulta strojního inženýrství, 2017. http://www.nusl.cz/ntk/nusl-318673.

Full text
Abstract:
The goal of submitted thesis is to perform a computer simulation of bubble creation in T-channel. In the first section of the paper, the theoretical applications of microfluidic bubble, micromachines and droplet formation are described. In the second part of the text, author uses cross flowing method for simulation od bubble creation. Furthermore, several settings in computer simulation software Fluent are mentioned. In addition, the influence of velocity at the T-channel inlet on surface tension and on bubble length is presented.
APA, Harvard, Vancouver, ISO, and other styles
4

Chen, Sihui. "Multiplexing microarrays with OSTEmer-biosticker : From polymer fabrication to bio analysis." Thesis, KTH, Skolan för elektroteknik och datavetenskap (EECS), 2017. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-253270.

Full text
Abstract:
Microarray technology provides powerful tools in the field of biomedicalresearch because it can measure molecular interactions in a highly parallelfashion. It has uses in protein, DNA or cell research, in both discovery anddiagnostic applications. Microfluidics, on the other hand, provides thenecessary tools to rapidly transport and mix small volumes of sample to amicro-sensor area. Bridging these two technologies has the potential todevelop a miniaturized, automated and ease-of-use toolbox for biologicalanalysis. However, the integration of microfluidics with microarrays is notstraightforward, as if a robust and leak-tight seal between the microarray andthe microfluidic channels. Current sealing methods are either impractical,such as mechanical clamping, or not compatible with proteins, such as heat orplasma bonding or gluing. Moreover the former methods create a permanentseal that, once applied prevents the microfluidic structure to be removed later.This work focuses on developing a microfluidic add-ons ("Biosticker") that canbe robustly sealed with protein microarrays with maintained biologicalactivity, but at the same time easily removed to allow for multiple stickersapplied in a sequence or scanning of the microarray in a standard reader. Thefeatures of the novel Biostickers are made possible by the use ofOff-stoichiometry thiol-ene-epoxy (OSTEmer) polymers. In this thesis, wedesign and fabricate Biostickers for rapid integration with pre-spottedmicroarrays and experimentally verify how these micropatterned Biostickerscan be used to significantly facilitate multiplexed assays, by avoiding the useof beads.<br>Microarray-tekniken är ett kraftfullt verktyg inom biomedicinsk forskningeftersom den kan mäta miljontals molekylära interaktioner parallellt. Den haranvändningsområden i protein-, DNA- eller cellforskning, både i forskningoch diagnostik. Mikrofluidik, å andra sidan, ger de nödvändiga verktygen föratt snabbt transportera och blanda små provvolymer till en sensoryta. Genomatt kombinera dessa två teknologier finns potential att utveckla enminiatyriserad, automatiserad och lättanvänd verktygslåda för biologiskanalys. Emellertid är integrationen av mikrofluidik med mikroarrayer inteenkel, då ytorna är känsliga, kanalerna mycket små men tätningen måste varaperfekt. De vanligast förekommande förseglingsmetoder är antingenopraktiska, som mekaniskt tryck eller så är de inte kompatibla med proteiner,som t.ex. värme- eller plasmabondning. Dessutom syftar de flestaförseglingsmetoder mot att skapa en permanent försegling som vidanvändning förhindrar mikrofluidikstrukturer från att tas bort i ett senareskede, tex. vid avläsning i en skanner. Detta arbete fokuserar på att utvecklamikrostrukturerade plastartiklar ("Biosticker") innehållande kanaler ochkaviteter. Dessa Biosticker kan på ett robust och läckfritt sätt kansammanfogas med proteinmikroarrayer utan att påverka den biologiskaaktivitetet men samtidigt kunna avlägsnas för att tillåta flera Biostickersapplicerade i en sekvens eller scanning i en mikroarrayläsare. Dessafunktioner möjliggörs genom av så kallade icke-stökiometrska-tiol-ene-epoxipolymerer (OSTEmer) används som material. I den här avhandlingenutvecklas och tillverkas Biostickers för snabb integrering medproteinmikroarrayer. Det verifieras även experimentellt hur dessa Biostickerskan användas för att underlätta genomförandet av sk. multiplexadeprotinanalyser.
APA, Harvard, Vancouver, ISO, and other styles
5

Hellmich, Wibke. "Einzelzellanalytik in Mikrofluidik-Systemen." [S.l.] : [s.n.], 2006. http://deposit.ddb.de/cgi-bin/dokserv?idn=980840015.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Pilát, Zdeněk. "Optical Micromanipulation Techniques Combined with Microspectroscopic Methods." Doctoral thesis, Vysoké učení technické v Brně. Fakulta strojního inženýrství, 2015. http://www.nusl.cz/ntk/nusl-234266.

Full text
Abstract:
Předložená dizertační práce se zabývá kombinací optických mikromanipulací s mikrospektroskopickými metodami. Využili jsme laserovou pinzetu pro transport a třídění živých mikroorganismů, například jednobuněčných řas, či kvasinek. Ramanovskou spektroskopií jsme analyzovali chemické složení jednotlivých buněk a tyto informace jsme využili k automatické selekci buněk s vybranými vlastnostmi. Zkombinovali jsme pulsní amplitudově modulovanou fluorescenční mikrospektroskopii, optické mikromanipulace a jiné techniky ke zmapování stresové odpovědi opticky zachycených buněk při různých časech působení, vlnových délkách a intenzitách chytacího laseru. Vyrobili jsme různé typy mikrofluidních čipů a zkonstruovali jsme Ramanovu pinzetu pro třídění mikro-objektů, především živých buněk, v mikrofluidním prostředí.
APA, Harvard, Vancouver, ISO, and other styles
7

Axel, Bolz. "Papierbasierte Mikrofluidik-Systeme mit SERS-Detektion." Doctoral thesis, Humboldt-Universität zu Berlin, 2019. http://dx.doi.org/10.18452/19765.

Full text
Abstract:
Schnelltests sind eine weit verbreitete Analysemethode, um vor Ort schnelle analytische Aussagen treffen zu können. Ein möglicher Zugang zu Schnelltests für Analyten in geringer Konzentration könnten Messung von Oberflächenverstärkten Raman-Spektren sein. In der vorliegenden Arbeit wird insbesondere auf drei Aspekte der SERS-Messungen (= Oberflächenverstärkte Raman-Streuung) eingegangen: die Reproduzierbarkeit der SERS-Signalintensität, die Interpretation der Konzentrationskurven und die Analyse von Probengemischen. Für die Untersuchung der Reproduzierbarkeit wurden verschiedene Auftragungsmethoden und Messsysteme getestet und es wurde untersucht, wie reproduzierbar die Signalintensitäten über einen längeren Zeitraum sind. Dabei wurde festgestellt, dass die Kombination von einer homogenen Auftragung der Nanopartikelsuspensionen auf dem Papier und ein großer Durchmesser des Laser- und Detektionspunktes auf der Probe zu einer stabileren Signalintensität führen. Die bei einem Labormessaufbau eine Stabilität des Messsignals von ca. 20 % relativer Standardabweichung über einen Zeitraum von ca. 2,5 Monaten lieferte. Für die Analyse und Auswertung der Abhängigkeiten der SERS-Signalintensität von der Konzentration des Analyten wurden Konzentrationsreihen von verschiedenen Verbindungen aufgenommen. Die Messdaten konnten mit einer Langmuir-Isotherme beschrieben und mit dem Langmuir-SERS-Modell erklärt werden. Für die gemessenen Thiolverbindungen wurde zudem noch eine weitere Möglichkeit der quantitativen Analyse gefunden, die auf der Auswertung der Verschiebung von bestimmten SERS-Banden im Spektrum in Abhängigkeit von der Analytkonzentration beruht. Für die Analysen der Mehrkomponenten-Lösungen wurden die Papierbasierten Mikrofluidik-Analysesysteme (µPADs) eingesetzt. Hier konnte beobachtet werden, dass Analyten aus einer Lösung auf Grund ihrer hohen Affinität zu den Nanopartikeln abgetrennt werden können und es so möglich ist, diese zu analysieren.<br>Rapid tests are widely used analytical methods for obtaining analytical information immediately on site. Surface enhanced Raman scattering (SERS) is a possible detection method for compounds in diluted samples. This thesis focuses mainly on three aspects: reproducibility of SERS signal intensity, interpretation of concentration curves and analysis of sample mixtures. The signal reproducibility was investigated using different deposition methods and measurement systems and the reproducibility of measurements was tested over longer periods of time. It was found that the most stable signal intensity was obtained using a combination of homogeneous deposition of a nanoparticle suspension on paper and a detection configuration that involves large diameters of both, the laser and the detection spot on the sample. It was shown with a laboratory setup, that comparatively stable measurements are possible with a relative standard deviation of approx. 20 % over a period of approx. 2.5 months. For the analysis and interpretation of the dependence of the SERS signal intensity on the concentration of the analyte, concentration series of different compounds were measured. The measurement data could be fitted with a Langmuir isotherm and explained with the Langmuir SERS model. For the measured thiol compounds an alternative option for quantification was found: the shift of certain SERS bands in the Raman spectrum as a function of analyte concentration. For the analysis of compound mixture in solution microfluidic paper-based analytical devices (µPADs) were used. It was observed that certain analytes which have a high affinity for the nanoparticles can be separated from the solution and thereby analyzed.
APA, Harvard, Vancouver, ISO, and other styles
8

Krause, Andreas. "Bisensitive interpenetrierende Polymernetzwerke für die Mikrofluidik." Doctoral thesis, Saechsische Landesbibliothek- Staats- und Universitaetsbibliothek Dresden, 2017. http://nbn-resolving.de/urn:nbn:de:bsz:14-qucosa-227597.

Full text
Abstract:
Die vorliegende Arbeit beschäftigt sich mit der Synthese und Charakterisierung bisensitiver Hydrogelsysteme für die Realisierung hoch leistungsfähiger chemischer Transistoren in der Mikrofluidik. Dabei wurden unterschiedliche (semi)interpenetrierende Polymernetzwerke auf Basis von N Isopropylacrylamid und Acrylsäure hergestellt und ihre Quelleigenschaften und mechanischen Stabilität bei unterschiedlichen Stimuli untersucht. Hierfür wurde die TANAKA-Kinetik modifiziert, um sie auf Proben unterschiedlicher Aspektverhältnisse anpassen zu können. Es zeigte sich der wechselseitige Einfluss der Teilnetzwerke auf die Quellgeschwindigkeit und Stabilität der (semi)interpenetrierende Polymernetzwerke. Durch eine Optimierung der Synthese konnten die Volumenänderungen der sensitiven Hydrogele gesteigert werden.
APA, Harvard, Vancouver, ISO, and other styles
9

Abrahám, Martin. "Návrh mikrofluidického směšovače." Master's thesis, Vysoké učení technické v Brně. Fakulta strojního inženýrství, 2016. http://www.nusl.cz/ntk/nusl-241127.

Full text
Abstract:
Microfluidic devices are more frequently being used in medicine as they operate with small amounts of test samples, such as blood or reagent chemicals. To work with such substances, effective mixing of the solution is usually required, which emerged as the most challenging problem in microfluidic systems. Due to the minor dimensions of the devices only laminar flow occurs, thus the turbulent eddies do not contribute to the mixing, but only the molecular diffusivity.
APA, Harvard, Vancouver, ISO, and other styles
10

Duong, Thanh Tu. "Neue Migrations- und Separationsmechanismen in strukturierten Mikrofluidik-Systemen." [S.l.] : [s.n.], 2006. http://deposit.ddb.de/cgi-bin/dokserv?idn=980237777.

Full text
APA, Harvard, Vancouver, ISO, and other styles
11

Günther, Daniel. "Bimorph-Piezoaktoren mit strukturierten Elektroden für die Mikrofluidik." kostenfrei, 2008. http://mediatum2.ub.tum.de/doc/628543/628543.pdf.

Full text
APA, Harvard, Vancouver, ISO, and other styles
12

Steiner, Thomas. "Dissipative particle dynamics simulation of microfluidic systems with fluid particle methods on high performance computers." Aachen Shaker, 2009. http://d-nb.info/995271100/04.

Full text
APA, Harvard, Vancouver, ISO, and other styles
13

Pirk, Tjalf. "The twin epipoly process a foundry process flow for a microfluidic application kit in silicon/glass." Aachen Shaker, 2008. http://d-nb.info/991379047/04.

Full text
APA, Harvard, Vancouver, ISO, and other styles
14

Pytlíček, Zdeněk. "Mikrosenzory plynů založené na samouspořádaných 3D nanovrstvách oxidů kovů." Doctoral thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2017. http://www.nusl.cz/ntk/nusl-263354.

Full text
Abstract:
This dissertation concerns the development, fabrication and integration in a gas sensing microdevice of a novel 3-dimensional (3D) nanostructured metal-oxide semiconducting film that effectively merges the benefits of inorganic nanomaterials with the simplicity offered by non-lithographic electrochemistry-based preparation techniques. The film is synthesized via the porous-anodic-alumina-assisted anodizing of an Al/Nb metal bilayer sputter-deposited on a SiO2/Si substrate and is basically composed of a 200 nm thick NbO2 layer holding an array of upright-standing spatially separated Nb2O5 nanocolumns, being 50 nm wide, up to 900 nm long and of 8109 cm2 population density. The nanocolumns work as semiconducting nano-channels, whose resistivity is greatly impacted by the surface and interface reactions. Either Pt or Au patterned electrodes are prepared on the top of the nanocolumn array using an innovative sensor design realized by means of microfabrication technology or via a direct original point electrodeposition technique, followed by selective dissolution of the alumina overlayer. For gas-sensing tests the film is mounted on a standard TO-8 package using the wire-bonding technique. Electrical characterization of the 3D niobium-oxide nanofilm reveals asymmetric electron transport properties due to a Schottky barrier that forms at the Au/Nb2O5 or Pt/Nb2O5 interface. Effects of the active film morphology, structure and composition on the electrical and gas-sensing performance focusing on sensitivity, selectivity, detection limits and response/recovery rates are explored in experimental detection of hydrogen gas and ammonia. The fast and intensive response to H2 confirms the potential of the 3D niobium-oxide nanofilm as highly appropriate active layer for sensing application. A computer-aided microfluidics simulation of gas diffusion in the 3D nanofilm predicts a possibility to substantially improve the gas-sensing performance through the formation of a perforated top electrode, optimizing the film morphology, altering the crystal structure and by introducing certain innovations in the electrode design. Preliminary experiments show that a 3D nanofilm synthesized from an alternative Al/W metal bilayer is another promising candidate for advanced sensor applications. The techniques and materials employed in this work are advantageous for developing technically simple, cost-effective and environmentally friendly solutions for practical micro- and nanodevices, where the well-defined nano-channels for charge carriers and surface reactions may bring unprecedented benefits.
APA, Harvard, Vancouver, ISO, and other styles
15

Walther, Ferdinand [Verfasser]. "Strukturierte Funktionalisierung von SU-8-Oberflächen für die Mikrofluidik / Ferdinand Walther." München : Verlag Dr. Hut, 2011. http://d-nb.info/101653163X/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
16

Nguyen, Nam-Trung. "Mikrofluidik : Entwurf, Herstellung und Charakterisierung ; mit 12 Tabellen und 37 Beispielen /." Stuttgart ; Leipzig ; Wiesbaden : Teubner, 2004. http://bvbr.bib-bvb.de:8991/F?func=service&doc_library=BVB01&doc_number=012935736&line_number=0001&func_code=DB_RECORDS&service_type=MEDIA.

Full text
APA, Harvard, Vancouver, ISO, and other styles
17

Zeysing, Björn. "Elektrochemisch aktive Thiole Darstellung, Untersuchung des Ladungstransfers und Anwendung in der Mikrofluidik /." [S.l. : s.n.], 2004. http://deposit.ddb.de/cgi-bin/dokserv?idn=971235961.

Full text
APA, Harvard, Vancouver, ISO, and other styles
18

Manz, Christina [Verfasser], and P. [Akademischer Betreuer] Nick. "Cell Fermentation and Microfluidics = Zellfermentation und Mikrofluidik / Christina Manz ; Betreuer: P. Nick." Karlsruhe : KIT-Bibliothek, 2019. http://d-nb.info/1183795742/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
19

Feldmann, Marco [Verfasser]. "Technologien und Applikationen der UV-Tiefenlithographie: Mikroaktorik, Mikrosensorik und Mikrofluidik / Marco Feldmann." Aachen : Shaker, 2007. http://d-nb.info/1166509257/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
20

Schmidt, Oliver. "Integration of chip-size wavelength detectors into optical sensing systems." [S.l.] : [s.n.], 2007. http://deposit.ddb.de/cgi-bin/dokserv?idn=985506644.

Full text
APA, Harvard, Vancouver, ISO, and other styles
21

Häberle, Stefan. "Multiphase microfluidics on a centrifugal platform /." Aachen : Shaker, 2008. http://d-nb.info/988194627/04.

Full text
APA, Harvard, Vancouver, ISO, and other styles
22

Schmitz, Christian Hermann Josef. "Entwicklung eines opto-mechanischen Mikrolabors zur Generierung und Untersuchung biomimetischer Proteinnetzwerke." [S.l. : s.n.], 2005. http://nbn-resolving.de/urn:nbn:de:bsz:16-opus-61296.

Full text
APA, Harvard, Vancouver, ISO, and other styles
23

Viertel, Julia. "Strömungslenkung zweier nicht mischbarer Flüssigkeiten durch Oberflächenstrukturierung im Mikrokanal." Tönning Lübeck Marburg Der Andere Verl, 2008. http://d-nb.info/993340040/04.

Full text
APA, Harvard, Vancouver, ISO, and other styles
24

Axel, Bolz [Verfasser], Panne [Gutachter] Ulrich, and Volmer [Gutachter] Dietrich. "Papierbasierte Mikrofluidik-Systeme mit SERS-Detektion / Bolz Axel ; Gutachter: Panne Ulrich, Volmer Dietrich." Berlin : Humboldt-Universität zu Berlin, 2019. http://d-nb.info/1182541720/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
25

Rapp, Bastian E. "Entwicklung eines Biosensorarray-Systems auf der Basis von akustischen Oberflächenwellensensoren mit integrierter einwegtauglicher Mikrofluidik." Karlsruhe Univ.-Verl. Karlsruhe, 2008. http://d-nb.info/992300665/04.

Full text
APA, Harvard, Vancouver, ISO, and other styles
26

Rapp, Bastian E. "Entwicklung eines Biosensorarray-Systems auf der Basis von akustischen Oberflächenwellensensoren mit integrierter einwegtauglicher Mikrofluidik." Karlsruhe : Universitätsverlag, 2009. http://digbib.ubka.uni-karlsruhe.de/volltexte/1000009924.

Full text
APA, Harvard, Vancouver, ISO, and other styles
27

Fleger, Markus. "Polymerbasierte Mikrofluidiksysteme mit integrierten optischen Komponenten." Tönning Lübeck Marburg Der Andere Verl, 2008. http://d-nb.info/989996751/04.

Full text
APA, Harvard, Vancouver, ISO, and other styles
28

Kauzlarić, David. "Particle simulation of MEMS,NEMS components and processes - theory, software design and applications." Tönning Lübeck Marburg Der Andere Verl, 2009. http://d-nb.info/99703100X/04.

Full text
APA, Harvard, Vancouver, ISO, and other styles
29

Malsch, Daniell [Verfasser], Michael [Akademischer Betreuer] Köhler, Michiel T. [Akademischer Betreuer] Kreutzer, and Thomas [Akademischer Betreuer] Henkel. "Strömungsphänomene der tropfenbasierten Mikrofluidik / Daniell Malsch. Gutachter: Michiel T. Kreutzer ; Thomas Henkel. Betreuer: Michael Köhler." Ilmenau : Universitätsbibliothek Ilmenau, 2014. http://d-nb.info/104943773X/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
30

Feldmann, Marco [Verfasser], and Stephanus [Akademischer Betreuer] Büttgenbach. "Technologien und Applikationen der UV-Tiefenlithographie: Mikroaktorik, Mikrosensorik und Mikrofluidik / Marco Feldmann ; Betreuer: Stephanus Büttgenbach." Braunschweig : Technische Universität Braunschweig, 2019. http://d-nb.info/1231992522/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
31

Malsch, Daniell Verfasser], Michael [Akademischer Betreuer] [Köhler, Michiel T. [Akademischer Betreuer] Kreutzer, and Thomas [Akademischer Betreuer] Henkel. "Strömungsphänomene der tropfenbasierten Mikrofluidik / Daniell Malsch. Gutachter: Michiel T. Kreutzer ; Thomas Henkel. Betreuer: Michael Köhler." Ilmenau : Universitätsbibliothek Ilmenau, 2014. http://nbn-resolving.de/urn:nbn:de:gbv:ilm1-2014000032.

Full text
APA, Harvard, Vancouver, ISO, and other styles
32

Gloss, Daniel. "Der Einfluss von Wandrauheiten auf laminare Strömungen: Untersuchungen in Mikrokanälen." Göttingen Cuvillier, 2009. http://d-nb.info/996826165/04.

Full text
APA, Harvard, Vancouver, ISO, and other styles
33

Reichert, Michael. "Hydrodynamic Interactions in Colloidal and Biological Systems." [S.l. : s.n.], 2006. http://nbn-resolving.de/urn:nbn:de:bsz:352-opus-19302.

Full text
APA, Harvard, Vancouver, ISO, and other styles
34

Krause, Andreas [Verfasser], Brigitte [Akademischer Betreuer] [Gutachter] Voit, and Gerald [Gutachter] Gerlach. "Bisensitive interpenetrierende Polymernetzwerke für die Mikrofluidik / Andreas Krause ; Gutachter: Brigitte Voit, Gerald Gerlach ; Betreuer: Brigitte Voit." Dresden : Saechsische Landesbibliothek- Staats- und Universitaetsbibliothek Dresden, 2017. http://d-nb.info/1139977547/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
35

Mückl, Andrea [Verfasser], and Markus [Gutachter] Kollmann. "Bakterielle Kommunikation in der synthetischen Biologie quantifiziert mittels Einzelzell- (Tröpfchen) Mikrofluidik / Andrea Mückl ; Gutachter: Markus Kollmann." Düsseldorf : Universitäts- und Landesbibliothek der Heinrich-Heine-Universität Düsseldorf, 2018. http://d-nb.info/1157092314/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
36

Krause, Andreas Verfasser], Brigitte [Akademischer Betreuer] [Gutachter] Voit, and Gerald [Gutachter] [Gerlach. "Bisensitive interpenetrierende Polymernetzwerke für die Mikrofluidik / Andreas Krause ; Gutachter: Brigitte Voit, Gerald Gerlach ; Betreuer: Brigitte Voit." Dresden : Saechsische Landesbibliothek- Staats- und Universitaetsbibliothek Dresden, 2017. http://nbn-resolving.de/urn:nbn:de:bsz:14-qucosa-227597.

Full text
APA, Harvard, Vancouver, ISO, and other styles
37

Andersson, Hilda, Sofia Appelgren, Anna Boström, Siri Norlander, Emma Stam, and Miranda Stiernborg. "Snabba mikrofluidiska test möjliggör specialanpassad sjukvård : Utveckling av två designförslag med fokus på material, struktur och pump." Thesis, Uppsala universitet, Institutionen för biologisk grundutbildning, 2016. http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-295284.

Full text
Abstract:
Två designförslag har utvecklats för ett snabbtest av antibiotikakänslighet baserat på ettmikrofluidiskt system av Gradientech AB. Antibiotikaresistens är ett stort och växande problem ivärlden. För att förbättra diagnostiken av bakteriella blodinfektioner krävs snabbarediagnostiska tester vilket möjliggör specialanpassad behandling. Linjära gradienter av antibiotikai det mikrofluidiska systemet möjliggör snabbare detektion av antibiotikakänslighet jämfört meddiagnostiska test som används idag. Projektet har syftat till att anpassa testet utvecklat avGradientech AB för en klinisk marknad. Fokus har varit på material, pumpsystem och strukturför snabbtestet. De två designförslagen baseras på krav på ett pålitligt och billigt test som äranvändarvänligt och som minimerar smittorisker. Det ena designförslaget använder sig av enchipbaserad peristaltisk pump och det andra förslaget är ett trelagersystem med endiafragmapump. De två förslagen består av både hårdplast och ett elastiskt material. När dettatest kommer ut på den kliniska marknaden så kommer det förbättra vården av patienter medbakteriella blodinfektioner och minska sjukvårdskostnader. Testet kommer även minskabehovet av behandling med bredspektrumantibiotika och därmed hjälpa till att stoppa spridningav antibiotikaresistens.<br>Two designs were developed for a fast antibiotic susceptibility test (AST) based on a microfluidicsystem by Gradientech AB. Antibiotic resistance is a big and growing global problem. Fasterdiagnostic tests are needed to improve the diagnostics of bacterial infections and enablespecialized antibiotic therapy. Linear gradients of antibiotics in the microfluidic system in thisproject enables faster detection of antibiotic susceptibility compared to ASTs used today inhealth care. The aim of this project has been to adapt the test developed by Gradientech AB fora clinical market. The main focus has been on materials, pumping systems and structure of theAST. The two designs are based on requirements of a reliable and cheap test that is easy to useand minimizes the biohazard. The first design uses a chip-based peristaltic pump and the otherdesign is a three-layer structure with a diaphragm pump. The two designs consists of both arigid plastic material and an elastic material. When this test becomes available to the clinicalmarket it will improve the care of patients with bacterial blood infections and reduce healthcarecosts. It will also reduce the use of broad-spectrum treatment of antibiotics and help counteractincreased global antibiotic resistance.
APA, Harvard, Vancouver, ISO, and other styles
38

Hairer, Gabriel. "Fluidic microsystems for biochemical analysis." Aachen Shaker, 2009. http://d-nb.info/999573519/04.

Full text
APA, Harvard, Vancouver, ISO, and other styles
39

Bleil, Stefan. "Transportprozesse in niedrig dimensionalen getriebenen kolloidalen Systemen." [S.l. : s.n.], 2007. http://nbn-resolving.de/urn:nbn:de:bsz:93-opus-33258.

Full text
APA, Harvard, Vancouver, ISO, and other styles
40

Waldbaur, Ansgar [Verfasser]. "Entwicklung eines maskenlosen Fotolithographiesystems zum Einsatz im Rapid Prototyping in der Mikrofluidik und zur gezielten Oberflächenfunktionalisierung / Ansgar Waldbaur." Karlsruhe : KIT Scientific Publishing, 2013. http://www.ksp.kit.edu.

Full text
APA, Harvard, Vancouver, ISO, and other styles
41

Schreiber, Fedor [Verfasser], and Daniel [Akademischer Betreuer] Erni. "Sortieralgorithmen und -architekturen für Elektrowetting-basierte Mikrofluidik-Zellsorter-Chips und deren elektrofluiddynamische Untersuchung / Fedor Schreiber ; Betreuer: Daniel Erni." Duisburg, 2018. http://d-nb.info/1162840269/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
42

Kuhn, Claus. "Methode zur Auslegung mikrofluidischer Bauteile für beadbasierte Analysesysteme in der medizinischen Diagnostik." [S.l. : s.n.], 2005. http://nbn-resolving.de/urn:nbn:de:bsz:93-opus-25158.

Full text
APA, Harvard, Vancouver, ISO, and other styles
43

Faigle, Christoph. "The Optical Stretcher." Doctoral thesis, Saechsische Landesbibliothek- Staats- und Universitaetsbibliothek Dresden, 2016. http://nbn-resolving.de/urn:nbn:de:bsz:14-qucosa-202092.

Full text
Abstract:
The mechanical parameters of biological cells are relevant indicators of their function or of disease. For example, certain cancerous cells are more deformable than healthy cells. The challenge consists in developing methods that can measure these parameters while not affecting the cell. The Optical Stretcher is a microfluidic system that deforms single suspended cells without contact using lasers and determines the cells’ viscoelastic properties. The advantage compared to standard methods of molecular biology is that cells do not need to be treated with additional markers. Basic versions of the Optical Stretcher have existed for some years. These allow the measurement of homogeneous cell populations. Up until now, it was only possible to calculate average population values of compliance. To characterize inhomogeneous populations however, it is necessary to consider each single cell and measure additional mechanical or optical parameters such as the refractive index. This work highlights various extensions of the Optical Stretcher. A novel procedure, including an improved image processing algorithm, is presented to analyze mechanical data in real time. In combination with measurements of the optical refractive index, single cells can now be characterized in more detail. Moreover, it is now possible to extract interesting subpopulations that can be further examined with molecular biology techniques. Depending on the intended purpose, novel devices for cell measurements, based on microfluidic and optical considerations, are presented. The fundamental concept involves microstructured chips that can be integrated into a commercial microscope. These chips offer the possibility of separating measured cell populations according to their mechanical properties. This separation, including mathematical classification, is demonstrated. These methods are tested with cell types of differing mechanical properties to prove their applicability in practice. Single cells are sorted into their respective population of origin. These novel methods offer the possibility of a versatile device to be applied in biophysical research.
APA, Harvard, Vancouver, ISO, and other styles
44

Rapp, Bastian [Verfasser], and V. [Akademischer Betreuer] Saile. "Entwicklung eines Biosensorarray-Systems auf der Basis von akustischen Oberflächenwellensensoren mit integrierter einwegtauglicher Mikrofluidik / Bastian Rapp ; Betreuer: V. Saile." Karlsruhe : KIT Scientific Publishing, 2009. http://d-nb.info/1185223673/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
45

Vogt, Lorenz [Verfasser], Guntram [Akademischer Betreuer] Wagner, Guntram [Gutachter] Wagner, and Friedrich [Gutachter] Raether. "Additive Fertigung von Keramiken mittels Mikrofluidik und elektrophoretischer Abscheidung / Lorenz Vogt ; Gutachter: Guntram Wagner, Friedrich Raether ; Betreuer: Guntram Wagner." Chemnitz : Technische Universität Chemnitz, 2021. http://d-nb.info/1226116159/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
46

Rapp, Bastian E. [Verfasser], and V. [Akademischer Betreuer] Saile. "Entwicklung eines Biosensorarray-Systems auf der Basis von akustischen Oberflächenwellensensoren mit integrierter einwegtauglicher Mikrofluidik / Bastian Rapp ; Betreuer: V. Saile." Karlsruhe : KIT Scientific Publishing, 2009. http://nbn-resolving.de/urn:nbn:de:0072-99246.

Full text
APA, Harvard, Vancouver, ISO, and other styles
47

Synowzik, Sven. "Ein Beitrag zur experimentellen Untersuchung und Modellierung von Wärmeübergang und Druckverlust bei einer Zweiphasenströmung in Mikrokanälen." Dresden TUDpress, 2008. http://d-nb.info/994416067/04.

Full text
APA, Harvard, Vancouver, ISO, and other styles
48

Schulze, Philipp. "Beiträge zur Mikrochip-Elektrophorese." kostenfrei, 2009. http://www.opus-bayern.de/uni-regensburg/volltexte/2009/1314/.

Full text
APA, Harvard, Vancouver, ISO, and other styles
49

Waibel, Günther. "Miniaturisiertes Dosiersystem zur geregelten Dosierung von Tinte in einem Schreibgerät." [S.l. : s.n.], 2008. http://nbn-resolving.de/urn:nbn:de:bsz:93-opus-36023.

Full text
APA, Harvard, Vancouver, ISO, and other styles
50

Neumann, Christiane [Verfasser]. "Entwicklung einer Plattform zur individuellen Ansteuerung von Mikroventilen und Aktoren auf der Grundlage eines Phasenüberganges zum Einsatz in der Mikrofluidik / Christiane Neumann." Karlsruhe : KIT Scientific Publishing, 2013. http://www.ksp.kit.edu.

Full text
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!