Literatura académica sobre el tema "IEC 61131-7"

Crea una cita precisa en los estilos APA, MLA, Chicago, Harvard y otros

Elija tipo de fuente:

Consulte las listas temáticas de artículos, libros, tesis, actas de conferencias y otras fuentes académicas sobre el tema "IEC 61131-7".

Junto a cada fuente en la lista de referencias hay un botón "Agregar a la bibliografía". Pulsa este botón, y generaremos automáticamente la referencia bibliográfica para la obra elegida en el estilo de cita que necesites: APA, MLA, Harvard, Vancouver, Chicago, etc.

También puede descargar el texto completo de la publicación académica en formato pdf y leer en línea su resumen siempre que esté disponible en los metadatos.

Artículos de revistas sobre el tema "IEC 61131-7"

1

Newell, Josh, Linna Pang, David Tremaine, Alan Wassyng, and Mark Lawford. "Translation of IEC 61131-3 Function Block Diagrams to PVS for Formal Verification with Real-Time Nuclear Application." Journal of Automated Reasoning 60, no. 1 (2017): 63–84. http://dx.doi.org/10.1007/s10817-017-9415-7.

Texto completo
Los estilos APA, Harvard, Vancouver, ISO, etc.

Tesis sobre el tema "IEC 61131-7"

1

Legaspe, Edinei Peres. "Controlador fuzzy de código aberto para uso em controladores programáveis." Universidade de São Paulo, 2012. http://www.teses.usp.br/teses/disponiveis/3/3143/tde-30072013-214419/.

Texto completo
Resumen
Sistemas de controle fuzzy são amplamente empregados na indústria de controle de processos. Normalmente controlando variáveis analógicas, tais como pressão, temperatura, vazão, posição e velocidade. Hoje existem diversas soluções de mercado que permitem o uso da lógica fuzzy em CPs (Controladores programáveis). Porém essas soluções são proprietárias e de custo elevado. Adicionalmente existe a norma IEC 61131-7, introduzida no ano de 2000, que especifica sistemas fuzzy em CPs, onde a mesma define um conjunto de regras que permite a definição de algoritmos fuzzy independente do hardware de um fabricante de CPs. A adoção da norma IEC 61131-7 não vem acontecendo de uma maneira rápida, devido a diversos fatores, mas principalmente, por já existirem soluções proprietárias e personalizadas fornecidas pelos fabricantes de CPs. Portanto, a contribuição deste trabalho é um método de desenvolvimento de controladores fuzzy por retroalimentação usando como solução um sistema de código aberto ou livre. Este método propõe o uso de uma arquitetura de controle distribuído envolvendo PCs (Computadores pessoais) e CPs. A construção do controlador fuzzy foi feita em linguagem Java e liberada sobre licença de código aberto, assim permitindo o seu uso de forma gratuita em uma grande variedade de aplicações industriais. O método é baseado na norma IEC 61131-7 para a aplicação da lógica fuzzy em sistemas de automação industrial. Diversos testes foram realizados, tais como testes de mesa do software de controle, e até em uma planta real para validação de software de controle em operação real. Com os resultados dos testes foram obtidas diversas curvas de resposta no tempo, que permitem a avaliação do controlador e do software de controle. Após a execução dos testes e verificado o comportamento obtido pelas curvas, foi constatada a compatibilidade do software construído com a norma IEC 61131-7, assim permitindo o seu uso em outras aplicações.
Fuzzy control systems are largely applied at the processes control industry, usually controlling analogic variables, such as, pressure, temperature, outflow, position and speed. Nowadays, there are several market solutions which allow the Fuzzy Logic usage in PLCs (Programmable Logic Controllers), therefore, these solutions are proprietary and have a high cost. Additionally, there is the IEC 61131-7 standard, introduced in 2000, which specifies Fuzzy systems in PLCs. It defines a set of rules which allow the Fuzzy definition regardless of the hardware from the PLCs manufacturer. The adoption of the IEC 61131-7 standard is not happening effectively, due to many factors, but mainly because there are already proprietary and customized solutions provided by the PLCs manufacturers. The contribution provided by this report, is a method of Fuzzy control development by feedback using as solution, a free or open source code system. This method proposes the usage of a distributed control architecture involving both PCs (Personal Computers) and PLCs. The building of the Fuzzy controller was made in Java language and released under open source code license, allowing its use to be free in a great variety of industrial applications. The method is based on the IEC 61131-7 standard for the Fuzzy logic application in industrial automation. Several tests were performed, such as, software control table test, and even in a real plant for control software validation in a real operation. With the tests results were obtained quite a few response curves at time, which allow the evaluation of the controller and of the control software. After the tests executions and the verifying of the behavior obtained by the curves, it was stated the compatibility of the built software with the IEC 61131-7 standard, admitting it to be used in other applications.
Los estilos APA, Harvard, Vancouver, ISO, etc.

Libros sobre el tema "IEC 61131-7"

1

Automatisieren mit SPS Theorie und Praxis: IEC 61131-3; STEP 7; Bibliotheksbausteine; AS-i-Bus; PROFIBUS; Ethernet-TCP/IP; OPC; Steuerungssicherheit. 2nd ed. Vieweg+Teubner Verlag, 2002.

Los estilos APA, Harvard, Vancouver, ISO, etc.
2

Zastrow, Dieter, and Günter Wellenreuther. Automatisieren mit SPS Theorie und Praxis. IEC 61131-3, STEP 7, Bibliotheksprogramme, AS-i-Bus, PROFIBUS, Ethernet-TCP/IP, OPC, Steuerungssicherheit. Vieweg Verlag, 2002.

Los estilos APA, Harvard, Vancouver, ISO, etc.
3

Zastrow, Dieter, and Günter Wellenreuther. Automatisieren mit SPS Theorie und Praxis. IEC 61131-3, STEP 7, Bibliotheksprogramme, AS-i-Bus, PROFIBUS, Ethernet-TCP/IP, OPC, Steuerungssicherheit. Vieweg Verlag, 2001.

Los estilos APA, Harvard, Vancouver, ISO, etc.

Capítulos de libros sobre el tema "IEC 61131-7"

1

Wenger, Monika, Alois Zoitl, and Georg Schitter. "Automatic Reengineering of IEC 61131-Based Control Applications into IEC 61499." In Distributed Control Applications. CRC Press, 2017. http://dx.doi.org/10.1201/b19391-7.

Texto completo
Los estilos APA, Harvard, Vancouver, ISO, etc.
Ofrecemos descuentos en todos los planes premium para autores cuyas obras están incluidas en selecciones literarias temáticas. ¡Contáctenos para obtener un código promocional único!

Pasar a la bibliografía