Literatura académica sobre el tema "Robotized Tomography"
Crea una cita precisa en los estilos APA, MLA, Chicago, Harvard y otros
Consulte las listas temáticas de artículos, libros, tesis, actas de conferencias y otras fuentes académicas sobre el tema "Robotized Tomography".
Junto a cada fuente en la lista de referencias hay un botón "Agregar a la bibliografía". Pulsa este botón, y generaremos automáticamente la referencia bibliográfica para la obra elegida en el estilo de cita que necesites: APA, MLA, Harvard, Vancouver, Chicago, etc.
También puede descargar el texto completo de la publicación académica en formato pdf y leer en línea su resumen siempre que esté disponible en los metadatos.
Artículos de revistas sobre el tema "Robotized Tomography"
Kantelhardt, Sven R., Markus Finke, Achim Schweikard y Alf Giese. "Evaluation of a Completely Robotized Neurosurgical Operating Microscope". Neurosurgery 72, suppl_1 (1 de enero de 2013): A19—A26. http://dx.doi.org/10.1227/neu.0b013e31827235f8.
Texto completoLegnani, Federico G., Andrea Franzini, Luca Mattei, Andrea Saladino, Cecilia Casali, Francesco Prada, Alessandro Perin et al. "Image-Guided Biopsy of Intracranial Lesions with a Small Robotic Device (iSYS1): A Prospective, Exploratory Pilot Study". Operative Neurosurgery 17, n.º 4 (23 de enero de 2019): 403–12. http://dx.doi.org/10.1093/ons/opy411.
Texto completoLe Reun, Adrien, Kévin Subrin, Anthony Dubois y Sébastien Garnier. "Thermal drift and backlash issues for industrial robots positioning performance". Robotica, 28 de marzo de 2022, 1–20. http://dx.doi.org/10.1017/s0263574721002022.
Texto completoDr. Apoorva Singh, Dr. Akanksha, Dr Nidhi Mishra,. "A Deep Learning Approach for Detecting Diabetic Macular Edema through Analyzing Retinal Images". Mathematical Statistician and Engineering Applications 71, n.º 3s (19 de julio de 2022). http://dx.doi.org/10.17762/msea.v71i3s.21.
Texto completoTesis sobre el tema "Robotized Tomography"
Banjak, Hussein. "X-ray computed tomography reconstruction on non-standard trajectories for robotized inspection". Thesis, Lyon, 2016. http://www.theses.fr/2016LYSEI113/document.
Texto completoX-ray computed tomography (CT) is a powerful tool to characterize or localize inner flaws and to verify the geometric conformity of an object. In contrast to medical applications, the scanned object in non-destructive testing (NDT) might be very large and composed of high-attenuation materials and consequently the use of a standard circular trajectory for data acquisition would be impossible due to constraints in space. For this reason, the use of robotic arms is one of the acknowledged new trends in NDT since it allows more flexibility in acquisition trajectories and therefore could be used for 3D reconstruction of hardly accessible regions that might be a major limitation of classical CT systems. A robotic X-ray inspection platform has been installed at CEA LIST. The considered system integrates two robots that move the X-ray generator and detector. Among the new challenges brought by robotic CT, we focus in this thesis more particularly on the limited access viewpoint imposed by the setup where important constraints control the mechanical motion of the platform. The second major challenge is the truncation of projections that occur when only a field-of-view (FOV) of the object is viewed by the detector. Before performing real robotic inspections, we highly rely on CT simulations to evaluate the capability of the reconstruction algorithm corresponding to a defined scanning trajectory and data acquisition configuration. For this purpose, we use CIVA which is an advanced NDT simulation platform developed at CEA and that can provide a realistic model for radiographic acquisitions and is capable of simulating the projection data corresponding to a specific CT scene defined by the user. Thus, the main objective of this thesis is to develop analytical and iterative reconstruction algorithms adapted to nonstandard trajectories and to integrate these algorithms in CIVA software as plugins of reconstruction
Caravaca, Mora Oscar Mauricio. "Development of a novel method using optical coherence tomography (OCT) for guidance of robotized interventional endoscopy". Thesis, Strasbourg, 2020. http://www.theses.fr/2020STRAD004.
Texto completoThere exists an unmet clinical need to provide doctors with a new method that streamlines minimally invasive endoscopic treatment of colorectal cancer to single operator procedures assisted by in-situ and real-time accurate tissue characterization for informed treatment decisions. A promising solution to this problem has been developed at the ICube laboratory, in which the flexible interventional endoscope (Karl Storz) was completely robotized, so allowing a single operator to independently telemanipulate the endoscope and two insertable therapeutic instruments with a joint control unit. However, the robot-assisted flexible endoscope is subject to the same diagnostic accuracy limitations as standard endoscopy systems. It has been demonstrated that endoscopic optical coherence tomography (OCT) has a good potential for imaging disorders in the gastrointestinal tract and differentiating healthy tissue from diseased. Neither OCT, nor the robotized endoscope can solve the limitations of current standard of care for colon cancer management alone. Combining these two technologies and developing a new platform for early detection and treatment of cancer is the main interest of this work, with the aim of developing a state-of-the-art OCT imaging console and probe integrated with the robotized endoscope. The capabilities of this new technology for imaging of the interior of the large intestine were tested in pre-clinical experiments showing potential for improvement in margin verification during minimally invasive endoscopic treatment in the telemanipulation mode
Rémin, Hugo. "Automatisation de la tomographie robotisée de pièces de grandes tailles. : contributions à la planification de trajectoires synchronisées de bras robotiques". Electronic Thesis or Diss., Angers, 2025. http://www.theses.fr/2025ANGE0002.
Texto completoThe thesis explores the automation of robotic tomography for the analysis of large parts, a key challenge in industrial sectors such as aerospace and energy. The primary objective is to overcome two major obsta cles: the feasibility of trajectories in complex configuration spaces and the scheduling of robotic tasks, while addressing strict synchronization and collision avoidance constraints. The first contribution is based on an innovative method that employs decomposition into [x]-contractible tiles, combining interval analysis and graph theory. This approach efficiently calculates the number of connected components in configuration spaces, offering a significant improvement in computational complexity compared to state of the art techniques. The second contribution introduces the Max-MatRTSP algorithm, specifically designed to coordinate two robots in a tomographic environment. This algorithm simultaneously integrates trajectory planning and task scheduling, accounting for specific industrial con straints. Validated through simulations and ex- periments on real systems, it has demon strated superior performance compared to existing methods
Actas de conferencias sobre el tema "Robotized Tomography"
Rémin, Hugo, Sébastien Lagrange, Laurent Dollé y Sébastien Lahaye. "A Task Scheduling Algorithm for Robotized X-Ray Tomography". En 2024 9th International Conference on Robotics and Automation Engineering (ICRAE), 198–204. IEEE, 2024. https://doi.org/10.1109/icrae64368.2024.10851685.
Texto completoLiao, Guiqiu, Zhongkai Zhang, Oscar Caravaca Mora, Philippe Zanne, Benoit Rosa, Diego Dall’Alba, Paolo Fiorini, Michel de Mathelin, Florent P. Nageotte y Michalina J. Gora. "Colon lumen exploration with robotized optical coherence tomography catheter". En Endoscopic Microscopy XVII, editado por Melissa J. Suter, Guillermo J. Tearney y Thomas D. Wang. SPIE, 2022. http://dx.doi.org/10.1117/12.2609991.
Texto completoPiccin, Olivier, Pierre Renaud, Laurent Barbe´, Bernard Bayle, Benjamin Maurin y Michel de Mathelin. "A Robotized Needle Insertion Device for Percutaneous Procedures". En ASME 2005 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference. ASMEDC, 2005. http://dx.doi.org/10.1115/detc2005-84577.
Texto completo