Tesis sobre el tema "Tomografia"
Crea una cita precisa en los estilos APA, MLA, Chicago, Harvard y otros
Consulte los 50 mejores tesis para su investigación sobre el tema "Tomografia".
Junto a cada fuente en la lista de referencias hay un botón "Agregar a la bibliografía". Pulsa este botón, y generaremos automáticamente la referencia bibliográfica para la obra elegida en el estilo de cita que necesites: APA, MLA, Harvard, Vancouver, Chicago, etc.
También puede descargar el texto completo de la publicación académica en formato pdf y leer en línea su resumen siempre que esté disponible en los metadatos.
Explore tesis sobre una amplia variedad de disciplinas y organice su bibliografía correctamente.
Pimenta, Wanderson Maia. "Tomografia experimental de estados quânticos:: impIementação de tomografia mínima". Universidade Federal de Minas Gerais, 2010. http://hdl.handle.net/1843/IACO-84RRCW.
Texto completoEste trabalho tem como principal objetivo a implementação experimental da tomografia mínima utilizando um modulador espacial de luz. Para tal fim, utilizamos as propriedades dos fótons produzidos pela conversão paramétrica descendente bem como a geração de estados discretos e multidimensionais utilizando fendas múltiplas. Uma descrição teórica foi necessária para o entendimento do método da tomografia mínima. Foram escolhidos quatro estados que descrevem um tetraedro na esfera de Bloch e associados a estes estados, foram construídos quatro projetores, constituindo assim um POVM para a tomografia. Para a implementação experimental destes projetores, foram necessárias duas calibrações do modulador espacial. Valores de escalas de cinza e polarizações de entrada e saída foram determinados com o objetivo de aplicar diferenças de fase e/ou amplitudes específicas entre os feixes que passam por fendas múltiplas. Assim, através do estudo da tomografia mínima e do conhecimento do funcionamento do modulador espacial e suas respectivas calibrações, foi possível realizar experimentalmente as tomografias para um e dois qubits.
Glionna, Giuseppe. "Tomografia de hemácias". Universidade Federal de Minas Gerais, 2009. http://hdl.handle.net/1843/ESCZ-7ZFFXS.
Texto completoObjetos transparentes (objetos de fase) se tornam visíveis em um microscópio óptico operando em campo-claro, se o microscópio estiver desfocalizado operando em campo-claro é equivalente a um microscópio de contraste de fase, apresentando vantagens que serão discutidas nesta tese, em relação ao microscópio de contraste de fase convencional. A desfocalização introduz uma diferença de fase entre a luz transmitida (não-difratada) e a luz difratada pelo objeto, que ao serem recombinadas no plano de detecção e devido à interferência entre essas luzes, faz com que o objeto transparente se torne visível, com um contraste da imagem diferente de zero. Isto foi demonstrado em nosso laboratório em artigos e teses anteriores. Nesta tese, melhoramos o modelo ótico de microscopia de desfocalização, para que ele fosse válido para qualquer desfocalização, inclusive no limite assintótico de grandes desfocalizações e para maiores números de onda de difração. Obtivemos expressões teóricas para o contraste de objetos de fase compostos por uma e por duas interfaces paralelas. No limite de pequenas desfocalizações e pequenos números de onda de difração, da média temporal do contraste, podemos obter a forma de equilíbrio de hemácias, como demonstrado em publicação anterior deste laboratório. Nossa nova expressão é importante para estabelecer uma relação entre flutuações de contraste e flutuações na altura das superfícies da hemácia. Com este novo modelo óptico, nós mostramos que ao fazer uma varredura na posição do plano focal da objetiva (zf), como as superfícies das hemácias estão em posições diferentes em relação à z, elas são afetadas de fases diferentes e, portanto, podem ser distinguidas nesta técnica de microscopia de desfocalização. Este fato nos permite estudar as propriedades de cada superfície separadamente. Para flutuações com números de ondas maiores que 1 m-1, podemos aproximar a região central da hemácia como planos paralelos e aplicar o modelo óptico para objetos de fase com duas interfaces desenvolvidas nesta tese. Usando o modelo elástico recente de Auth et al, que leva em conta o acoplamento entre bicamada lipídica e o citoesqueleto de espectrina (que também considera as superfícies de hemácias como planos paralelos) e nosso modelo óptico, obtivemos um ótimo ajuste para os dados experimentais. Deste ajuste obtivemos os valores para o módulo de curvatura da bicamada, o módulo de cisalhamento do citoesqueleto e para a temperatura efetiva. As flutuações de altura em hemácia não são somente de origem térmica. Outra contribuição vem da conversão de energia química em trabalho mecânico nas superfícies, mediada por ATP (adenosina trifostato o combustível das células) Estes efeitos fora do equilíbrio são reduzidos a único parâmetro, qual seja a temperatura efetiva introduzida de uma maneira ad-hoc. Este efeito ainda é motivo de controvérsia na literatura. Estudamos também a relaxação destas flutuações analisando a função de auto-correlação temporal do contraste. Esta relaxação depende da elasticidade da bicamada lipídica e citoesqueleto de espectrina e do escoamento do citoplasma através do canal estreito, d espessura d da ordem de 20 a 30 nm, entre bicamada e o citoesqueleto. Do ajuste da teoria aos nossos dados obtivemos d=21±1nm. Mostramos que a técnica de microscopia de desfocalização é uma técnica de microscopia óptica bastante útil e confiável para o estudo do perfil e rugosidades dinâmicas e estática de interfaces em um material transparente em multicamadas, como membranas de células biológicas.
Perlin, Lourenço Panosso. "Tomografia ultrassônica em concreto". Florianópolis, SC, 2011. http://repositorio.ufsc.br/xmlui/handle/123456789/95463.
Texto completoMade available in DSpace on 2012-10-26T02:00:55Z (GMT). No. of bitstreams: 1 291197.pdf: 5731903 bytes, checksum: a2652036a9f0348e1c65fbf72f41df65 (MD5)
Nessa pesquisa efetua-se uma revisão bibliográfica da técnica ultrassônica convencional, demonstrando suas capacidades e limitações na localização de não homogeneidades no concreto. A proposta dessa dissertação é utilizar a técnica tomográfica aplicada com os resultados dos equipamentos já disponíveis para as leituras ultrassônicas no concreto, de modo a melhorar consideravelmente o potencial de visualização dessas não homogeneidades. Para tal, a tomografia também é estudada e adaptada ao uso com o ultrassom. Como é indispensável a utilização de programas de computador para a resolução do problema tomográfico, também nessa pesquisa é efetuada a implementação computacional da tomografia adaptada para o uso do ultrassom. Com o programa TUCon implementado e numericamente verificado, vários ensaios experimentais são executados em corpos de prova de concreto sem armadura e com diferentes não homogeneidades internas conhecidas. Pesquisadores internacionais afirmam que a técnica da tomografia ultrassônica em concreto tem grandes potencialidades para ser utilizada na reconstituição de seções internas de concreto para identificação de não homogeneidades. Através de ensaios experimentais, os resultados dessa dissertação reafirmam tal constatação.
This work presents a review of the ultrasonic pulse velocity method, showing its capacity and limitations for internal flaws identification in plain concrete members. To further improve this ability, the main goal of this work is to use the tomography technique with the results from of conventional ultrasonic equipment already available. Thus, the tomography theory is also presented and adapted to be used with ultrasound equipment. Since is necessary to solve the system of equations yielded by the tomography technique, a software was developed in this work, called TUCon. After TUCon has been numerically checked, several experiments were performed on plain concrete specimens with known internal flaws. International researchers agree that ultrasonic tomography technique has great potential to be used in the reconstitution of internal sections of concrete members and to identify flaws. The experiments performed in this work endorse this statement.
Accettola, Alessandra. "Tomografia quantistica: applicabilità e limiti". Bachelor's thesis, Alma Mater Studiorum - Università di Bologna, 2020. http://amslaurea.unibo.it/19973/.
Texto completoSaddy, Mario Sergio. "\"Estudo comparativo entre a tomografia computadorizada e a tomografia volumétrica na confecção de modelos de prototipagem\"". Universidade de São Paulo, 2006. http://www.teses.usp.br/teses/disponiveis/23/23139/tde-22032007-120737/.
Texto completoThe purpose of this study is to compare rapid prototyping models created from cone beam computerized tomography (CBCT) and multislice computerized tomography (CT) data, in order to verify the accuracy of these technologies. A dry skull mandible was submitted in a CBCT (NewTom ? QR, Italy) and CT (Select SP-Elscint, Israel) exams. The tomographies data were processed by two different Medical Image processing systems, 3D-Analyze (Mayo Clinic, U.S.A.) and InVesalius (CenPRA, Brazil). Rapid prototypes models were built in two different rapid prototyping technologies, 3D Printer (3DP) and Selective Laser Sintering (SLS). The dry skull mandible (gold standard) and the eight prototypes, as follows; I-CT-Analyze?3DP; IICT- Invesalius?3DP; III-CT-Analyze?SLS; IV-CT-Invesalius-SLS; V-CBCT-Analyze? 3DP; VI-CBCT-Invesalius?3DP; VIII-CBCT-Analyze?SLS; VIII-CBCT-Invesalius-SLS, were submitted to a reverse engineering process aimed to digitalize the surfaces of the objects to compare each rapid prototype model with the gold standard with a precision of 0.001mm. Percentage deviations errors until 1.0mm and 2.0mm were calculated, compared and statistically analyzed. The prototyped models obtained with multislice computerized tomography data shows more accuracy than those obtained with data from cone beam computerized tomography.
Silva, Isabela Maria de Carvalho Crusoé. "Avaliação comparativa dos coeficientes de Hounsfield entre a tomografia computadorizada de feixe cônico e tomografia multislice". [s.n.], 2011. http://repositorio.unicamp.br/jspui/handle/REPOSIP/290135.
Texto completoDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-09-11T21:16:55Z (GMT). No. of bitstreams: 1 Silva_IsabelaMariadeCarvalhoCrusoe_M.pdf: 2322395 bytes, checksum: 2378f18e1c22e49e20d1b9f0670b3d52 (MD5) Previous issue date: 2011
Resumo: O objetivo no presente estudo foi comparar os coeficientes das unidades de Hounsfield (HU) em imagens adquiridas por tomografia de Feixe Cônico e tomografia multislice. Para tanto, foram utilizadas imagens de vinte mandíbulas maceradas adquiridas em dois tomógrafos: tomógrafo multislice de 40 canais (Somatom Sensation 40 - Siemens) com protocolo de cortes axiais de 0,7 mm de espessura e intervalo entre os cortes de 0,5 mm; e tomógrafo de feixe cônico i-CAT (Imaging Sciences International), com cortes axiais de 0,2 mm de espessura, tempo de aquisição de 40 segundos e Field of View (FOV) de 8 cm. As análises das imagens foram feitas pelos softwares Syngo CT (tomógrafo multislice). Os valores obtidos por este último foram considerados como Padrão Ouro. Para as mensurações foram utilizadas as coordenadas X e Y, bem como a ferramenta de HU de ambos os softwares. Ficando assim, viável a comparação dos resultados após as Análises Estatísticas Descritivas e do Teste t pareado. Os dados obtidos indicaram um valor médio das regiões de interesse de 313,13 HU para a tomografia multislice e de 418.06 HU para a tomografia de feixe cônico, com valor de P < 0,001. Portanto, os valores de HU, obtidos pelo software da tomografia de feixe cônico, apresentaram-se superestimados em relação aos encontrados no Tomógrafo multislice. Na ausência de correspondência entre os dados amostrados, a tomografia de feixe cônico não oferece segurança e credibilidade ao cirurgião-dentista na avaliação da densidade óssea no planejamento para implantes e em cirurgias do complexo maxilofacial
Abstract: The aim of this study was to compare the attenuation coefficients (Hounsfield Unit) in both cone-beam computed tomography (CT) and multislice CT images. The 40-channel CT scanner (SOMATOM Sensation 40 - Siemens) was used to obtain images (n=20) of macerated mandibles considering the following protocol: axial slices of 0.7 mm in thickness and an interval of 0.5 mm between cuts. This same sample was submitted to i-CAT cone-beam CT scanner (Imaging Sciences International): axial slices of 0.2 mm in thickness and a field of view of 8 cm. Images were analyzed by means of computer software - XoranCat (cone-beam CT scan) and the Syngo CT (multislice CT scan) - the latter of which was considered Gold Standard. Coordinates X and Y and the HU tool were used for the measurements. Data were submitted to the descriptive statistical analysis and the paired sample t-test. A mean value of 313.13 HU was obtained for Multislice CT and 418.06 HU for the cone-beam CT (p<0.001). The attenuation coefficient values obtained for the cone-beam CT were overestimated when compared to those for the multislice CT. Since no correspondence was found among the data sampled, cone-beam CT offers no credibility for the dentist to evaluate bone during planning of implant and/or maxillofacial complex surgery
Mestrado
Radiologia Odontologica
Mestre em Radiologia Odontológica
La, Ciacera Giorgio. "Tomografia computerizzata a fascio conico (CBCT)". Bachelor's thesis, Alma Mater Studiorum - Università di Bologna, 2016. http://amslaurea.unibo.it/12315/.
Texto completoSilva, Alcenísio José de Jesus. "Probabilidades negativas e tomografia de Qubits". Universidade Federal de São Carlos, 2007. https://repositorio.ufscar.br/handle/ufscar/4997.
Texto completoFinanciadora de Estudos e Projetos
In this dissertation we approached the tomography of discrete systems, understood as the representation and the reconstruction of states. For the tomography we used distribution functions of symmetrical pseudo-probabilities. The coefficients of the distribution function of "probabilities" are "joint probabilities", that eventually can be negative, associated to incompatible observables. The "negative probabilities" contains not only information about the measurements of counts, but also on the quantum state of the systems. We present the argument of Scully, Walther and Schleich that uses double slit interference to give a meaning to the "negative probabilities" and we propose one alternative example using beam splitters and an single photon. Like this, moreover we define distribution functions based in generalized quantization axes for any directions, we present the physical interpretation of the resulting "negative probabilities". We showed the reason because all explanation usually done to justify "negative probabilities" seems to be contradictory and are not convincing. Is the interpretation of the "negative probabilities" that retain the heart, not only of the present work, but also, of the whole Quantum Mechanics, its only mystery, as Feynman says
Nesta dissertação abordamos a tomografia de sistemas discretos, entendida como a representação e a reconstrução de estados. Para a tomografia utilizamos funções distribuição de pseudo-probabilidades simétricas. Os coeficientes dessa função distribuição de "probabilidades" são "probabilidades conjuntas", que eventualmente podem ser negativas, associadas a observáveis incompatíveis. As "probabilidades negativas" contém não só informação sobre as medições de contagens, mas também sobre o estado quântico dos sistemas. Apresentamos o argumento de Scully, Walther e Schleich que utiliza interferência na dupla-fenda para dar um significado às "probabilidades negativas" e propomos um exemplo alternativo utilizando divisores de feixe e um único fóton. Assim, além de definir funções de distribuição baseadas em eixos de quantização generalizados para direções quaisquer, apresentamos a interpretação física das "probabilidades negativas" decorrentes. Mostramos porque toda explicação que possa ser feita para justificar "probabilidade negativa" parece ser contraditória e não é convincente. É na interpretação das pseudo-probabilidades onde está o coração não só do presente trabalho, mas também, de toda a Mecânica Quântica, o seu único mistério, como diz Feynman
Fonseca, Filho Paulo Roberto da [UNESP]. "Tomografia por biosusceptometria de corrente alternada". Universidade Estadual Paulista (UNESP), 2014. http://hdl.handle.net/11449/123264.
Texto completoCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
A busca por novos métodos de imagens, principalmente os livres de radiação ionizante, são importantes tanto pelas instrumentações, quanto para as finalidades. A Biosusceptometria de |Corrente Alternada (BAC) possui versatilidade, sensibilidade, baixo custo e têm sido amplamente utilizada na aquisição de imagens para estudos nas áreas de gastrenterologia, fisiologia, farmacologia e farmácia. O objetivo deste trabalho foi caracterizar sistemas de BAC na produção de imagens tomográficas de objetos simuladores, propondo a viabilidade da técnica de tBAC - tomografia por biosusceptometria de Corrente Alternada. Para tanto, os gradiômetros de dois sistemas BAC com 13 e 37 canais com compensação de campo de excitação foram avaliados quanto à sua sensibilidade e resolução para produzir imagens de simuladores de barras e cilíndri-cos. Foi possível reconstruir imagens de todos os objetos com boa correlação entre a imagem e as caracte-rísticas físicas dos objetos (forma e concentração de traçador magnético). As melhores imagens foram pro-duzidas quando foi utilizada aquisição multicanal no sistema de BAC com 37 sensores utilizando compen-sação de campo, os quais possuem menores diâmetros. Dessa forma verificou-se que os sistemas BAC podem ser empregados com sucesso para produzir imagens tomográficas de objetos com pequena quanti-dade de traçador magnético, o que viabiliza sua aplicação futura em pequenos animais, farmacotecnia ou ainda ensaios não destrutivos
The development of new imaging methods, especially those that are free of ionizing radiation, constitute a very important topic because for both instrumentation development and its applications. The Alternating Current Biosusceptometry (ACB) has versatility, sensibility and low cost and has been widely used on image acquisition on gastroenterology, physiology, pharmaceutics and pharmacology researches. The aim of this project was to characterize ACB systems to produce tomographic images of simulating objects ver-ifying the technical viability of the AC Biosusceptometry Tomography (ACBT). The capability of ACB gradiometers of 13 and 37 channel systems with compensation field to reconstruct images of bars and cy-lindrical phantoms were evaluated, especially sensibility and resolution. It was possible to reconstruct im-ages from all objects with good correlation between the image and the phantom (geometry and magnetic tracer concentration). Better results were observed while using multichannel acquisition on 37-channel sys-tem with active excitation magnetic field. Therefore we verified that ACB systems can be successfully used on tomographic imaging of objects with small quantities of magnetic tracer, which is viable to future ap-plication on small animal physiology, pharmaceutics or non-destructive evaluation research
Valente, Marcelo. "Torus Palatinus: estudo por Tomografia Computadorizada\"". Universidade de São Paulo, 1999. http://www.teses.usp.br/teses/disponiveis/5/5151/tde-18092014-113201/.
Texto completoWe prospectively studied the behavior of calcifications, atrophy, white matter and vascular abnormalities on the images of computed tomography (CT) of 162 children and adolescents infected with the human immunodeficiency virus (HIV) acquired by vertical transmission, who are or were clinically followed in the Ambulatory of Pediatric Infectology of the Children Institute at the Clinics Hospital of University of São Paulo Medical School, from 1992 to 2002. We analyzed the possible correlation between these abnormalities, as well as, their evolutive aspects. For this purpose, we evaluated 606 CT scans (mean 3.74 exams per patient), which composed the group of study. After the characterization according to the presence or not of the anomalies mentioned above, and their possible inter-relations, we performed a statistical analysis of the obtained results with the Fisher test with a level of significance below 5%. Later, these aspects were evaluated regarding its evolutive behavior in a subgroup of 61 patients (mean, 4.18 exams per patient, summing 321 exams). These patients had, at least, four serial cranial CT (with minimum interval of ninety days between the subsequent exams and, at least, two years of total interval between the first and the fourth exam). The cranial CT abnormalities presented were assessed individually as absent or present. Initially, the set results were assessed individually (for each patient) and, later in relation to the totality of the group. Calcifications were found in 46.30% of all patients, atrophy in 37.65%, white matter abnormalities in 25.93% and vascular anomalies in 25.19%. We found a significant correlation between white matter abnormalities and atrophy, as well as, between calcifications and vascular anomalies. Evolutive analysis of these characteristics demonstrated a significant increase of the abnormalities between the first and the fourth moment, with emphasis to the calcifications and vascular anomalies. We concluded that, calcifications and atrophy were the most frequent abnormalities in this series of children and adolescents with HIV acquired by vertical transmission. Atrophy and white matter abnormalities presented a significant correlation in the descriptive sample, as well as, vascular anomalies and calcifications that also demonstrated a significant evolutive association regarding its progression
Fonseca, Filho Paulo Roberto da. "Tomografia por biosusceptometria de corrente alternada /". Botucatu, 2014. http://hdl.handle.net/11449/123264.
Texto completoBanca: Oswaldo Baffa Filho
Banca: Roberto Morato Fernandez
Banca: Fernando Gomes Romeiro
Banca: Valmir Fadel
Resumo: A busca por novos métodos de imagens, principalmente os livres de radiação ionizante, são importantes tanto pelas instrumentações, quanto para as finalidades. A Biosusceptometria de |Corrente Alternada (BAC) possui versatilidade, sensibilidade, baixo custo e têm sido amplamente utilizada na aquisição de imagens para estudos nas áreas de gastrenterologia, fisiologia, farmacologia e farmácia. O objetivo deste trabalho foi caracterizar sistemas de BAC na produção de imagens tomográficas de objetos simuladores, propondo a viabilidade da técnica de tBAC - tomografia por biosusceptometria de Corrente Alternada. Para tanto, os gradiômetros de dois sistemas BAC com 13 e 37 canais com compensação de campo de excitação foram avaliados quanto à sua sensibilidade e resolução para produzir imagens de simuladores de barras e cilíndri-cos. Foi possível reconstruir imagens de todos os objetos com boa correlação entre a imagem e as caracte-rísticas físicas dos objetos (forma e concentração de traçador magnético). As melhores imagens foram pro-duzidas quando foi utilizada aquisição multicanal no sistema de BAC com 37 sensores utilizando compen-sação de campo, os quais possuem menores diâmetros. Dessa forma verificou-se que os sistemas BAC podem ser empregados com sucesso para produzir imagens tomográficas de objetos com pequena quanti-dade de traçador magnético, o que viabiliza sua aplicação futura em pequenos animais, farmacotecnia ou ainda ensaios não destrutivos
Abstract: The development of new imaging methods, especially those that are free of ionizing radiation, constitute a very important topic because for both instrumentation development and its applications. The Alternating Current Biosusceptometry (ACB) has versatility, sensibility and low cost and has been widely used on image acquisition on gastroenterology, physiology, pharmaceutics and pharmacology researches. The aim of this project was to characterize ACB systems to produce tomographic images of simulating objects ver-ifying the technical viability of the AC Biosusceptometry Tomography (ACBT). The capability of ACB gradiometers of 13 and 37 channel systems with compensation field to reconstruct images of bars and cy-lindrical phantoms were evaluated, especially sensibility and resolution. It was possible to reconstruct im-ages from all objects with good correlation between the image and the phantom (geometry and magnetic tracer concentration). Better results were observed while using multichannel acquisition on 37-channel sys-tem with active excitation magnetic field. Therefore we verified that ACB systems can be successfully used on tomographic imaging of objects with small quantities of magnetic tracer, which is viable to future ap-plication on small animal physiology, pharmaceutics or non-destructive evaluation research
Doutor
Corrente, Diogo Emílio da Fonseca Ussemane Pires. "Tomografia computorizada intraoperatória na artrodese lombar". Master's thesis, Universidade de Aveiro, 2013. http://hdl.handle.net/10773/9916.
Texto completoO presente relatório desenvolvido com base na prática clínica tem como objetivo demonstrar a importância da utilização da Tomografia Computorizada Intraoperatória (iTC) na realização de artrodese lombar, sendo este um procedimento que consiste na fusão de uma ou mais vértebras lombares de modo a aliviar a dor relacionada com certas patologias. A fusão entre as vértebras ocorre através da utilização de excertos ósseos ou outros materiais, como ligas metálicas, polímeros, compósitos ou cerâmicos. De modo a ajudar no processo de fusão são também utilizados dispositivos de fixação tais como parafusos pediculares, hastes e barras. A possibilidade de reconstruções MPR (Multiplanar Reformation) e VRT (Volume Rendering Technique), assim como a possibilidade de variar as janelas de visualização das imagens de iTC permitem uma melhor descriminação anatómica e, consequentemente, que a utilização da iTC, quando comparada com a do intensificador de imagem móvel, seja mais precisa na avaliação da colocação dos parafusos pediculares, evitando possíveis lesões causadas pela sua má colocação.
This report developed in clinical practice aims to demonstrate the importance of the intraoperative Computed Tomography (iCT) in the lumbar arthrodesis performance. It consists in the fusion of single or multiple lumbar vertebrae in order to relieve the pain related to some specific pathologies. The vertebral fusion is accomplished using bone grafts or other materials such as bone substitutes, metal alloys, polymers, composites or ceramics. In order to assist in the interbody fusion process, fixation devices such as pedicle screws, rods and plates are also used. The possibility of MPR (Multiplanar Reformation) and VRT (Volume Rendering Technique) reconstructions, as well as the ability of changing the windows levels of iCT images, allow a better anatomical discrimination and consequently, when compared with commonly used the mobile C-arm, the iCT appears more accurate in evaluating the placement of pedicle screws, avoiding possible injuries caused by their misplacement.
Rocha, João Pedro Mendes. "Tomografia sísmica da Litosfera Continental Algarvia". Master's thesis, Universidade de Évora, 2010. http://hdl.handle.net/10174/21019.
Texto completoMAGALHÃES, Cinthia Marques Sousa de. "Dosimetria em tomografia computadorizada utilizando fototransistor". Universidade Federal de Pernambuco, 2007. https://repositorio.ufpe.br/handle/123456789/9978.
Texto completoO aumento do uso da tomografia computadorizada (CT) na prática médica e a dose relativamente alta proporcionada ao paciente fazem da CT um forte contribuinte na dose populacional em radiologia médica. Portanto, existe a necessidade de avaliar e otimizar as doses de radiação em CT para os pacientes submetidos a essa técnica de radiodiagnóstico. A dosimetria atual é baseada na medida da integral do perfil de dose para um único corte utilizando uma câmara de ionização de 100 mm de extensão. Contudo, um sistema alternativo tem sido sugerido através da utilização de detectores menores. Nesse trabalho, o fototransistor OP520 foi proposto para avaliar a dose em raios-X de tomógrafo. Inicialmente, foi feita a caracterização do fototransistor em laboratório e no hospital. Em seguida, o detector foi utilizado no tomógrafo para avaliar o perfil de dose de um único corte no ar e num simulador de cabeça. Essas medidas foram feitas transladando o fototransistor através do feixe, utilizando múltiplas rotações da fonte e diferentes extensões de varredura. Os resultados da caracterização do fototransistor mostraram que o dispositivo apresenta resposta similar a do detector padrão para diferentes potenciais de tubo no experimento com o tomógrafo. As respostas em função da dose e da taxa de dose apresentaram comportamento linear, com coeficientes de determinação maiores que 0,95. A dependência angular foi expressiva nas irradiações em laboratório, mas no tomógrafo essa dependência foi menor que 3%. Os resultados das medidas do perfil de dose mostraram que o sensor pode ser utilizado para determinar os detalhes da distribuição de dose de um único corte em CT. Ao utilizar uma varredura de 100 mm de extensão, os perfis de dose obtidos com os fototransistores foram comparados com indicadores convencionais de dose no paciente em CT obtidos com a câmara de ionização: o índice de dose em tomografia computadorizada (CTDI) e o CTDI ponderado (CTDIw). A partir daí, obtiveram-se fatores de conversão para converter a medida em nC para dose em mGy e os indicadores puderam ser obtidos utilizando o fototransistor. Efetuando uma varredura de 150 mm de extensão, ao invés dos 100 mm usual, foi observado que existe dose além do comprimento da câmara de ionização em concordância com a opinião de alguns autores de que a dosimetria atual pode deixar de ser adequada
Perlin, Lourenço Panosso. "Tomografia ultrassônica em concreto e madeira". reponame:Repositório Institucional da UFSC, 2015. https://repositorio.ufsc.br/xmlui/handle/123456789/158870.
Texto completoMade available in DSpace on 2016-02-09T03:13:15Z (GMT). No. of bitstreams: 1 337478.pdf: 14260207 bytes, checksum: 2d17c4effaa380cc7a6b68e56a497c89 (MD5) Previous issue date: 2015
As edificações estão expostas a diversos tipos de ações degradativas, requerendo que inspeções periódicas sejam executadas. Para auxiliar estas inspeções, diferentes ensaios não destrutivos podem ser empregados, entre eles, o ultrassônico. Esta tese pesquisou a teoria tomográfica e demonstrou como a mesma pode ser utilizada para melhorar consideravelmente o resultado do ensaio ultrassônico, permitindo a visualização interna de seções transversais de elementos estruturais de concreto e madeira. Para isso, é descrito a implementação do programa computacional tomográfico TUCOM, responsável pela obtenção de tomogramas. A teoria empregada possibilita o cálculo de um caminho não retilíneo do pulso ultrassônico, contornando não homogeneidades e regiões de baixa velocidade. Além disso, através das equações de Christoffel e Hankinson, e pela discretização dos anéis de crescimento da madeira, foi possível incorporar a natureza anisotrópica das peças de madeira dentro do processamento tomográfico. Simulações numéricas e ensaios experimentais foram executados e utilizados no TUCOM, que emitiu tomogramas onde foi possível visualizar as diferentes formas de não homogeneidades conhecidas, demonstrando então as capacidades do método. Esta pesquisa confirmou que a tomografia ultrassônica é uma importante ferramenta na avaliação de possíveis patologias presentes em elementos estruturais de concreto e madeira.
Abstract : The buildings are exposed to several types of degradative actions, requiring the execution of periodic inspections. In order to help in these inspections, different non-destructive test methods can be used, with the ultrasonic pulse velocity being one of them. This thesis presents a research on the tomographic theory and its application to concrete and wood structural elements. It is demonstrated how tomography can be used to greatly improve the outcome of ultrasonic testing, allowing to visualize the internal cross-sections of concrete and wood structural elements. The implementation of tomographic software TUCOM, which supplies tomograms is described. Non-straight paths of the ultrasonic pulse were implemented, which avoid internal flaws and low density regions. Furthermore, using Christoffel and Hankinson equations, and the discretization of the wood growth rings, it was possible to incorporate the anisotropic nature of wood species in the tomographic processing. Numerical simulations and experimental tests were performed with TUCOM. In the generated tomograms it was possible to visualize the different shapes of known internal flaws, thus demonstrating the capabilities of the method. This research confirmed that the ultrasonic tomographic is an important tool in the evaluation of possible pathologies present in concrete and wood structural elements.
Basso, Caio Ferraz. "Padronização do volume pulmonar pela tomografia". Botucatu, 2019. http://hdl.handle.net/11449/183536.
Texto completoResumo: A medida correta e acurada do volume pulmonar é uma importante ferramenta de avaliação diagnóstica e terapêutica na prática clínica. Atualmente, com o avanço da capacidade de reconstrução tridimensional da Tomografia Computadorizada (TC) é possível mensurar o volume pulmonar total por este aparelho. O presenta trabalho busca apresentar uma nova técnica de mensuração do volume pulmonar e estabelecer uma padronização de valores normais do volume pulmonar na população adulta. O volume pulmonar total de 95 pacientes, assim como quatro medidas antropométricas obtidas na TC foram analisados. Em um intervalo de confiança de 95%, se estabeleceu os limites inferiores e superiores da relação entre o volume e cada uma das medidas, assim valores de importância estatística.
Abstract: Correct and accurate measurement of lung volume is an important diagnostic and therapeutic evaluation tool in clinical practice. Nowadays, with the advancement of the capacity of three-dimensional reconstruction of Computed Tomography (CT), it is possible to measure the total lung volume by this device. The present paper aims to present a new technique for measuring lung volume and establish a standardization of normal values of lung volume in the adult population. The total lung volume of 95 patients, as well as four anthropometric measurements obtained at CT were analyzed. In a 95% confidence interval, we established the lower and upper limits of the relationship between the volume and each of the measures, thus values of statistical importance.
Mestre
Nanni, Giacomo. "Tomografia a coerenza ottica: principi ed applicazioni". Bachelor's thesis, Alma Mater Studiorum - Università di Bologna, 2016. http://amslaurea.unibo.it/11568/.
Texto completoHelou, Neto Elias Salomão. "Algoritmos incrementais com aplicações em tomografia computadorizada". [s.n.], 2009. http://repositorio.unicamp.br/jspui/handle/REPOSIP/307603.
Texto completoTese (doutorado) - Universidade Estadual de Campinas, Instituto de Matematica, Estatistica e Computação Cientifica
Made available in DSpace on 2018-08-13T11:27:52Z (GMT). No. of bitstreams: 1 HelouNeto_EliasSalomao_D.pdf: 7993687 bytes, checksum: 12333395c593dd0cbddf79352f61c458 (MD5) Previous issue date: 2009
Resumo: O problema de viabilidade convexa é um campo fértil de pesquisa que deu origem a uma grande quantidade de algoritmos iterativos, tais como pocs, art, Cimmino e uma miríade de variantes. O motivo para tal interesse é o amplo leque de aplicabilidade que algoritmos gerais para a solução de problemas desse tipo podem alcançar. Dentre tais aplicações encontra-se a reconstrução de imagens em tomografia, caso que geralmente apresenta uma estrutura especial de esparsidade e tamanhos gigantescos. Também bastante estudados por seu interesse prático e teórico são problemas envolvendo a minimização irrestrita de funções convexas. Aqui, novamente, a variada gama de aplicações torna impossível mencionar uma lista minimamente abrangente. Dentre essas a tomografia é, outra vez, um exemplo de grande destaque. No presente trabalho desenvolvemos uma ponte que permite o uso de uma variedade de métodos para viabilidade em conjunto com algoritmos de otimização para obter a solução de problemas de otimização convexa com restrições. Uma teoria geral de convergência é apresentada e os resultados teóricos são especializados em métodos apropriados para problemas de grande porte. Tais métodos são testados em experimentos numéricos envolvendo reconstrução de imagens tomográficas. Esses testes utilizam-se da teoria de amostragem compressiva desenvolvida recentemente, através da qual conseguimos obter resultados sem par na reconstrução de imagens tomográficas a partir de uma amostragem angular altamente esparsa da transformada de Radon. Imagens obtidas a partir de dados simulados são recuperadas perfeitamente com menos de 1/20 das amostras classicamente necessárias. Testes com dados reais mostram que o tempo de uma leitura spect pode ser reduzido a até 1/3 do tempo normalmente utilizado, sem grande prejuízo para as reconstruções.
Abstract: The convex feasibility problem is a research field which has originated a large variety of iterative algorithms, such as pocs, art, Cimmino and a myriad of variants. The reason for such interest is the wide array of applicability that general algorithms for this kind of problem may reach. Among such applications there is tomographic image reconstruction, instance that generally presents a special sparsity structure and huge sizes. Also widely studied because its practical and theoretical interests are problems involving unconstrained minimization of convex functions. Here, again, the huge array of applications makes it impossible to mention even a minimal list. Among these, once more, tomography is a major example. In the present work we have developed a bridge that allows the use of a variety of methods for feasibility in conjunction with optimization algorithms in order to obtain the solution for convex optimization problems with restrictions. A general convergence theory is presented and the theoretical results are specialized into methods useful for large scale problems. These methods are tested in experiments involving tomographic image reconstruction. Such tests make use of the recently developed compressive sensing theory, through which we have been able to obtain unmatched results in tomographic image reconstruction from highly sparse angular sampling from the Radon transform. Images obtained from simulated data are perfectly reconstructed using less than 1/20 from the classically needed. Tests with real data show that the time of a spect scan can be reduced to 1/3 of the usual, without too much image deterioration.
Doutorado
Matematica Aplicada
Doutor em Matemática Aplicada
Gonçalves, Douglas Soares 1982. "Métodos matemáticos em tomografia de estados quânticos". [s.n.], 2013. http://repositorio.unicamp.br/jspui/handle/REPOSIP/305944.
Texto completoTese (doutorado) - Universidade Estadual de Campinas, Instituto de Matemática, Estatística e Computação Científica
Made available in DSpace on 2018-08-21T21:36:13Z (GMT). No. of bitstreams: 1 Goncalves_DouglasSoares_D.pdf: 2439739 bytes, checksum: 5c9361d700cb32cae7880de49fa5e892 (MD5) Previous issue date: 2013
Resumo: A preparação, manipulação e caracterização de sistemas quânticos são tarefas essenciais para a computação quântica. Em Tomografia de Estados Quânticos, o objetivo é encontrar uma estimativa para a matriz de densidade, associada a um ensemble de estados quânticos identicamente preparados, baseando-se no resultado de medições. Este é um importante procedimento em computação e informação quântica, sendo aplicado, por exemplo, para verificar a fidelidade de um estado preparado ou em tomografia de processos quânticos. Nesta tese, estudamos métodos matemáticos aplicados aos problemas que surgem na reconstrução de estados quânticos. Na estimação por Máxima Verossimilhança, apresentamos dois métodos para a resolução dos problemas de otimização dessa abordagem. O primeiro se baseia em uma reparametrização da matriz de densidade e, neste caso, provamos a equivalência das soluções locais do problema de otimização irrestrita associado. No segundo, relacionado à verossimilhança multinomial, demonstramos a convergência global do método sob hipóteses mais fracas que as da literatura. Apresentamos também duas formulações para o caso de tomografia com um conjunto incompleto de medidas: Máxima Entropia e Tomografia Quântica Variacional. Propusemos uma nova formulação para a segunda, de modo a apresentar propriedades mais parecidas as da Máxima Entropia, mantendo a estrutura de um problema de programação semidefinida linear. Para outros problemas de otimização sobre o espaço de matrizes de densidade além do problema da Tomografia de Estados Quânticos, apresentamos um método de Gradiente Projetado que se mostrou efetivo em testes numéricos preliminares. Por fim, discutimos sobre a implementação de inferência Bayesiana, através de métodos Monte Carlo via cadeias de Markov, no problema de estimação da matriz de densidade
Abstract: Preparation, manipulation and characterization of quantum states are essential tasks for quantum computation. In Quantum State Tomography, the aim is to find an estimate for the density matrix associated to an ensemble of identically prepared quantum systems, based on the measurement outcomes. This is an important procedure in quantum information and computation applied for instance, to verify the fidelity of a prepared state or in quantum process tomography. In this thesis we study mathematical methods applied to problems that raise from the reconstruction of quantum states. In the Maximum Likelihood Estimation we present two methods to solve the optimization problems of this approach. The first one is based on a reparameterization of the density matrix and, in this case, we prove the equivalence of local solutions of the related unconstrained optimization problem. In the second one, related to multinomial likelihoods, we prove the global convergence of the method under weaker assumptions than those of literature. We also discuss two formulations to the case of quantum state tomography with incomplete measurements: Maximum Entropy and Variational Quantum Tomography. We propose a new formulation for the second one in order to have a similar behavior to the Maximum Entropy approach, keeping the linear semidefinite positive programming structure. Furthermore, in order to solve other optimization problems over the density matrices space besides the Quantum State Tomography, we present a Projected Gradient method which shows a good performance in preliminary numerical tests. We also briefly talk about the implementation of a Bayesian inference scheme, through Monte Carlo Markov chains methods, to the density matrix estimation problem
Doutorado
Matematica Aplicada
Doutor em Matemática Aplicada
Carvalho, Maria de Fátima M. N. Marques Vaz de. "Protecção radiológica do doente em tomografia computorizada". Master's thesis, Universidade Nova de Lisboa. Escola Nacional de Saúde Pública, 2011. http://hdl.handle.net/10362/6866.
Texto completoSelistre, Luciano da Silva. "Nefropatia induzida por contraste após tomografia computadorizada". Pontifícia Universidade Católica do Rio Grande do Sul, 2009. http://hdl.handle.net/10923/4427.
Texto completoContrast-induced nephropathy (CIN) is defined as worsening in renal function after administration of parenteral contrast and exclusiona of other causes. CIN is usually manifested as acute non-oliguric renal failures. Cases of CIN are usually defined by a fixed (0. 5 mg/dl) or proportionate (25%) rise in serum creatinine levels 24-48 hours after exposure to the contrast medium. Prevention strategies are based on the correction of factors leading to the development of CIN and are divided into choice of less nephrotoxic contrast (non-ionic); improvement in the patient’s clinical status through hydration; use of drugs that reduce renal vasoconstriction and oxidative stress; and temporary suspension of drugs with nephrotoxic potential or that are hamful in case of reduced glomerular filtration. This review aims on the management recommendations to prevent its occurrence.
A nefropatia por contraste (NIC) é definida como uma piora na função renal que se segue à administração de contraste parenteral, tendo sido excluídas outras causas. A NIC manifesta-se, usualmente, como uma insuficiência renal aguda não oligúrica. Por definição, deve haver um aumento na creatinina basal de 25-50% ou um aumento superior a 0,5 mg/dl de 24 a 48 horas após o uso vascular de contraste. As medidas de prevenção são baseadas na correção dos fatores que levam ao desenvolvimento da NIC e dividem-se em: escolha de agentes de contrastes menos nefrotóxicos (não-iônicos) e utilização de doses menores; melhora no estado clínico do paciente com hidratação; uso de drogas que reduzam vasoconstrição renal e estresse oxidativo; e suspensão temporária de drogas com potencial nefrotóxico ou prejudiciais, no caso de diminuição da filtração glomerular. Essa revisão tem o objetivo de examinar as principais recomendações de manejo para prevenir sua ocorrência.
Francesco, Sílvia de. "Simulação e reconstrução em tomografia cardio-torácica". Doctoral thesis, Universidade de Aveiro, 2009. http://hdl.handle.net/10773/2219.
Texto completoEsta dissertação aborda o tema da Tomografia Axial Computorizada com especial enfoque na reconstrução da imagem, ou seja, nos métodos matemáticos que, dado um conjunto de amostras da intensidade de radiação X transmitida, recolhidas segundo uma geometria de irradiação específica, permitem obter o mapa da distribuição tri-dimensional (3D) do coeficiente de atenuação linear no interior do objecto. Em termos mais formais, dado que, do ponto de vista matemático, o processo de aquisição dos dados corresponde à amostragem da transformada de Radon da função que descreve a distribuição do coeficiente de atenuação no volume sob estudo, estamos interessados nos métodos matemáticos que permitem calcular a transformada inversa de Radon a partir de conjuntos suficientemente densos de amostras. O ambiente de simulação utilizado, desenvolvido de forma a permitir a aquisição de amostras da transformada de Radon de um modelo digital dinâmico do tórax humano (4D MCAT) segundo qualquer uma das geometrias de amostragem actualmente em uso nos equipamentos modernos, permitiu a implementação e avaliação de novos métodos de reconstrução. Nomeadamente, são propostos novos métodos de reconstrução rápida baseados na teoria de Fourier e no cálculo da transformada de Fourier a partir de amostras não equiespaçadas, quer para geometria de aquisição paralela quer divergente, e é abordado o tema da reconstrução dinâmica sendo exploradas várias técnicas de reconstrução que permitem reduzir os efeitos do movimento nos estudos cardio-torácicos. Os estudos realizados permitem demonstrar que o desempenho dos métodos de Fourier propostos é equivalente, no que respeita à qualidade de imagem, ao desempenho do método de Retroprojecção Filtrada, habitualmente utilizado nos equipamentos comerciais mas a custos computacionais significativamente mais baixos.
This thesis addresses the theme of Computed Tomography, with special emphasis on tomographic reconstruction techniques, this means, the mathematical methods which, given a set of samples of transmitted radiation intensity, acquired with a specific sampling geometry, provide a threedimensional (3D) map of linear attenuation coefficient of the given object. Since, from a mathematical point of view, the acquisition process corresponds to the sampling of the Radon transform of the function describing the spatial distribution of attenuation coefficient in the volume under study, we are interested in methods and algorithms leading to diverse numerical implementations of the inverse Radon transform from sufficiently dense sets of samples. The developed simulation environment, capable to perform virtual acquisition of Radon transform’s samples of a digital anatomical model, in our case the dynamical digital model of human thorax (4D MCAT), through any of the sampling geometries currently used in commercial equipments, enabled the implementation and evaluation of new reconstruction methods. We propose new methods for fast reconstruction based on Fourier theory and on the calculation of Fourier transform for non-equispaced samples, both for parallel and for divergent acquisition geometries, and we deal with the topic of dynamic reconstruction, by exploring some reconstruction techniques capable of minimizing movement artifacts in cardio-thoracic images. The studies performed demonstrated that the performance of the proposed Fourier methods regarding image quality is similar to the Filtered Backprojection method, traditionally used in commercial equipments but at significantly lower computational costs.
Sassi, Andrea. "PET (Positron Emission Tomography) e tomografia computerizzata". Bachelor's thesis, Alma Mater Studiorum - Università di Bologna, 2013. http://amslaurea.unibo.it/4961/.
Texto completoDoiche, Danuta Pulz [UNESP]. "Estudo tomográfico do encéfalo de cães dolicocefálicos, mesaticefálicos e branquicefálicos clinicamente sadios". Universidade Estadual Paulista (UNESP), 2011. http://hdl.handle.net/11449/88996.
Texto completoFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
A Tomografia Computadorizada (TC), juntamente com a Ressonância Magnética, são modalidades de diagnóstico por imagem avançadas, consideradas de escolha para a avaliação do sistema nervoso, por fornecerem imagens livres de sobreposições e detectarem pequenas diferenças de densidade tecidual. Dentro de qualquer estudo, o conhecimento das possíveis formas de apresentação de cada estrutura e a determinação do limite entre o fisiológico e o alterado são fundamentais para um estudo preciso. O presente trabalho teve como objetivo a descrição dessas variações nas imagens tomográficas do encéfalo, no que diz respeito aos ventrículos laterais e atenuação do parênquima encefálico e cerebelar entre os grupos aqui estipulados (grupo dolicocefálico composto por cães pastores Alemães, grupo mesaticefálico composto por Rottweilers e grupo braquicefálico compostos por cães da raça Boxer) e assim enriquecer a avaliação cerebral à TC e minimizar erros de interpretação. Foram detectadas diversas diferenças individuais e entre os grupos à avaliação qualitativa. Quantitativamente, houve diferença da altura ventricular entre os braquicefálicos e os demais, mostrando que ainda não é possível apenas uma faixa de valores da altura ventricular comum a todos os cães, e que, para as raças braquicefálicas o valor da razão da altura ventricular e encefálica até 25% pode servir como limite superior nos animais hígidos. Os valores de atenuação finais na fase pré-contraste são compatíveis com trabalhos anteriores, o bulbo olfatório e o cerebelo apresentaram-se diferentes estatisticamente em relação aos demais locais. A única raça que teve nas fases simples e contrastada diferenças estatísticas em todos os locais foram os animais do grupo B
Computed tomography (CT) along with Magnetic Ressonance Imaging (MRI) are diagnostic imaging modalities of advanced, considered choice for the evaluation of the nervous system, for providing free images overlap and detect small differences in tissue density. Within any study, knowledge of the possible forms of presentation of each structure and determining the limit between physiological and change are fundamental to a precise study. This study aimed to describe these variations in the tomographic images of the brain, with respect to the lateral ventricles and attenuation of brain parenchyma and cerebellum between the groups set forth herein (dolichocephalic group composed of German shepherd dogs, a group composed of rottweilers and mesaticephalic brachycephalic group consisting of Boxer dogs) and thus enrich the evaluation of brain CT and minimize misunderstandings. We detected several differences between individuals and groups in the qualitative assessment of the aspects mentioned. Quantitatively, there were differences between the ventricular height between brachycephalic and others, showing that it is not possible just a strip of ventricular height values common to all dogs, and that for brachycephalic breeds the value of 25% can serve as upper limit in healthy animals. The final attenuation values in the pre-contrast are consistent with previous works, the olfactory bulb and cerebellum were different statistically when compared to other locations. The only race that was simple and contrasted phases statistical differences in all sites were the animals in group B
Helou, Neto Elias Salomão. "Teoria e experimentação com metodos incrementais relaxados em tomografia por emissão". [s.n.], 2005. http://repositorio.unicamp.br/jspui/handle/REPOSIP/305809.
Texto completoDissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Matematica, Estatistica e Computação Cientifica
Made available in DSpace on 2018-08-14T01:15:10Z (GMT). No. of bitstreams: 1 HelouNeto_EliasSalomao_M.pdf: 1733678 bytes, checksum: 44e680915a74638897d279b1d09a007f (MD5) Previous issue date: 2005
Resumo: O principal assunto desta dissertação é a teoria e prratica em metodos iterativos incrementais relaxados para reconstrução estatística de imagens em Tomografia por Emissão de Positrons - PET. Especial atenção é dedicada ao estudo teorico dos algoritmos, com a apresentação de resultados novos sobre convergência com o parâmetro de relaxação variando dentre as subiterações e sobre a regularidade da sequência gerada por tais algoritmos no caso específico da função de log-verossimilhança que surge em PET. Alem disso, uma comparação experimental entre a qualidade da imagem obtida com metodos relaxados e não relaxados é efetuada
Abstract: The main subject of this dissertation is the theory and practice in iterative incremental relaxed methods for statistical image reconstruction in Positron Emission Tomograpy | PET. Special atention is drawn to the theoretical study of the algorithms, with the presentation of new results concerning convergence with a relaxation parameter wich is allowed to vary within the subiterations and about the regularity of the sequence generated by such algorithms in the specific case of the log-likelihood function that arises in PET. Furthermore, an experimental comparsion is made to test the quality of the image obtained with relaxed methods against those generated by non-relaxed ones
Mestrado
Mestre em Matemática Aplicada
SARMENTO, DANIELE M. "Avaliação dos níveis de radiação ambiental no laboratório de tomografia por emissão de pósitrons acoplada a tomografia computadorizada, microPET/CT". reponame:Repositório Institucional do IPEN, 2016. http://repositorio.ipen.br:8080/xmlui/handle/123456789/26611.
Texto completoMade available in DSpace on 2016-08-26T11:07:48Z (GMT). No. of bitstreams: 0
O sistema microPET/CT é um importante equipamento utilizado nas pesquisas de imagem diagnóstica em pequenos animais. O radiofármaco mais usado nesta tecnologia é o fluordeoxiglicose marcado com flúor-18. Este estudo tem como objetivo efetuar o controle radiológico no laboratório de pesquisa microPET/CT do Centro de Radiofarmácia do IPEN-CNEN/SP, de forma a satisfazer tanto as normas nacionais como as recomendações internacionais. O laboratório está classificado pela equipe de radioproteção da instalação como área supervisionada, nas quais embora não seja obrigatória a adoção de medidas específicas de proteção e segurança, devem ser submetidas reavaliações regulares das condições do ambiente de trabalho. Visando assegurar a proteção radiológica dos trabalhadores diretamente envolvidos no manuseio do equipamento, realizou-se o monitoramento do local de trabalho e a avaliação do controle de dose individual. Inicialmente foi feito o monitoramento pré-operacional, isto é, o levantamento radiométrico no laboratório. Além disso, mediu-se nível de radiação externa nas instalações do laboratório e suas adjacências, por meio da colocação de nove dosímetros termoluminescentes (TL) de CaSO4:Dy, em locais previamente selecionados. Os indivíduos ocupacionalmente expostos foram avaliados mensalmente por meio do uso de dosímetros TL posicionados no tórax e por medidas de corpo inteiro, tomadas a cada seis meses. O período do estudo foi de dois anos, com início em abril de 2014. Para o controle do microPET/CT realizou-se testes de desempenho de acordo com o protocolo padrão do equipamento e em conformidade com a norma desenvolvida pela força tarefa para estudos com PET em animais Animal PET Standard Task Force. O presente estudo permitiu demonstrar que os níveis de radiação das áreas (estimativas de dose ambiente e dose efetiva), assim como a blindagem do equipamento estão adequados de acordo com os limites da exposição ocupacional. Ressalta-se a importância de se seguir rigorosamente os princípios de radioproteção, já que se trata de pesquisas com fontes radioativas não seladas.
Dissertação (Mestrado em Tecnologia Nuclear)
IPEN/D
Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP
Sarmento, Daniele Martins. "Avaliação dos níveis de radiação ambiental no laboratório de tomografia por emissão de pósitrons acoplada a tomografia computadorizada, microPET/CT". Universidade de São Paulo, 2016. http://www.teses.usp.br/teses/disponiveis/85/85131/tde-01072016-132544/.
Texto completoMicro PET/CT scanner is an essential tool generally used for small animal molecular imaging. Fluorine-18-labeled fluorodeoxyglucose is the most widely used radioisotope in this technique. The present study aimed to evaluate the radiation levels in a micro PET/CT research laboratory of the Radiopharmacy Center at IPEN-CNEN / SP, in order to accomplish both national standards and international recommendations. The radioprotection team has classified the laboratory as supervised area; even this laboratory does not require the adoption of specific measures for protection and safety, should be done regular re-evaluation of the conditions of occupational exposures. Workplace monitoring and individual control assessment were carried out to ensure the radiological protection of all workers directly involved in handling the scanner. Initially, there was conducted a radiometric survey, as well as measurements of the external radiation level in the workplace and its surroundings. To achieve this goal, there were placed nine thermoluminescent dosimeters of CaSO4:Dy in preselected locations. Monthly evaluations of the occupationally exposed individuals were carried out through the use of TL dosimeters, ported in the workers´ chest. Moreover, whole body measurements were performed every six months. The study period was about two-years which started in April 2014. All tests to evaluate micro PET/CT performance were based on the standard protocol of the equipment in accordance with the standard developed by the Animal PET Standard Task Force. Present study\'s results demonstrated that the ambient radiation levels (ambient and effective estimated radiation dose), as well as the effective shielding equipment are both adequate. This study emphasizes that it is essential to strictly follow the principles of radioprotection in workplace, whenever researches involve radioactive unsealed sources.
Morselli, Gianluca. "Tomografia computerizzata: l’evoluzione e la tecnologia Turbo Flash". Bachelor's thesis, Alma Mater Studiorum - Università di Bologna, 2018.
Buscar texto completoMusial, Josue Ervin. "Técnicas de reconstrução algébricas aplicadas em tomografia computadorizada". reponame:Repositório Institucional da UFPR, 2010. http://hdl.handle.net/1884/24909.
Texto completoNajera, Omar Cipriano Usuriaga. "Tomografia de emissão H-alfa no tokamak TCABR". Universidade de São Paulo, 2006. http://www.teses.usp.br/teses/disponiveis/43/43134/tde-27022008-133846/.
Texto completoA study of the tomography profile of the emission of the line of Hydrogen, atomic H-alpha line (?=656.28 nm), was carried out in TCABR, a medium-size tokamak in operation at the Laboratory of Plasma Physics of the Institute of Physics of the University of São Paulo. Our work focuses on the study of the effects of due to the introduction of a biased electrode in the plasma edge of the TCABR tokamak. The electrode could be introduced up to 1.5 cm inside the plasma, without plasma disruptions for positive voltages from 0 to +350V, and was located on the equatorial plane of the plasma column. Tomography profiles of H-alpha with and without bias were measured. Comparison of the profiles shows an increase of the central line-averaged density, while the emissivity of the line H-alpha decreases. The analysis of the tomography profiles of H-alpha, time of confinement of particles and also the study of recycling of the neutral particles, indicate that the confined plasma enters the H-mode regime. Calculations of turbulence and transport at the Scrape-Off-Layer, using measured floating potentials and ion saturation currents, show a strong decrease in the power spectra and transport. The H-alpha tomography was also employed to study the new regime of runaway discharges that has been discovered in the TCABR tokamak. The distinctive features of this regime are weakly ionized low-temperature plasma detached from the limiter due to the recombination process, and a relaxation instability with strong spikes of H-alpha emission correlated with sawtooth relaxation of the line density. In the present thesis we report experimental data on conditions for generation of these discharges. The runaway electron production is analyzed; show that generation of runaway electrons can only be explained by the runaway avalanche mechanism. The confirmation of low plasma temperature is a obtained from an analysis of the tomography profile of H-alpha emission. This emission cannot be explained by excitation by plasma electrons. Recombination, on the other hand, gives a rather plausible explanation for the time dependency of the emission, in particular at high neutral densities.
Mauro, Rodrigo Antonio Pereira. "Dosimetria em tomografia computadorizada de feixe cônico odontológica". Universidade de São Paulo, 2017. http://www.teses.usp.br/teses/disponiveis/59/59135/tde-21112017-193930/.
Texto completoThe objectives of this study are to characterize the radiodiagnostic reference levels for computed tomography of dental cones and as performance characteristics of equipment such as peak kyvoltage, yield, semi-reducing layer, etc., in order to know the levels of the values in that users are exposed, thus allowing to identify more adequate image acquisition protocols, taking in basic concepts of radioprotection, and also to test the capacity of such equipment in a quality image. The Cone Beam CT scan has become active, useful in medical, medical, dental, on the Internet, in any situation, minimizes as possibilities of errors, allows for more reliable and clear diagnoses, having a direct influence on the final result expected by the patient. Because it is an imaging technique that uses ionizing radiation, careful attention should be given to radiation levels, in addition to implementing a quality control routine. The dosimetric parameter most commonly used in computed tomography is the Computed tomography dose index, however, when applied to dental tomography, the conic geometry of the beam and still the extension of the field of view make this greatness unfeasible and deceptive, so it is done The. standardization of a more optimized dosimetric quantity, to avoid an underestimation of the dose levels in beams of wide range. The PKA has been used as a possible dosimetric magnitude in dental tomography, since in its measurement methodology, the whole beam is encompassed by the meter, it does not depend on the source - detector distance, besides being sensitive to the exposure parameters. Therefore, it is proposed that PKA be used for the establishment of reference dose levels in dental diagnosis. The PKA values obtained for this study ranged from 34.6 mGy.cm^2 to 2901.6 mGy.cm^2, with a mean value of 980.7 mGy.cm^2. The values found for the levels of radiodiagnostic reference values calculated from the 3rd quartile are divided into three classes referring to the size of the field of vision, where for small, medium and large fields are the values are 1241 mGy.cm^2, 1521 mGy.cm^2 and 1408 mGy.cm^2 respectively, and 1446 mGy.cm^2 is the global independent value of the field of view. The quality control tests were all positive, with an attention to the i-CAT FLX, which slightly exceeded the acceptable limit for kVp accuracy. A face between CTDI100 and CTDI300, reported that the CTDI300 is on average 49% higher than the CTI100. Radiodiagnostic reference levels are representative of optimized dose levels and serve as a basis for adequacy and optimization of the exposure parameters of the equipment. The quality control tests alert to possible irregularities in the operation of the tomograph, and develop properly from the clinical process.
Selistre, Luciano da Silva. "Nefropatia induzida por contraste ap?s tomografia computadorizada". Pontif?cia Universidade Cat?lica do Rio Grande do Sul, 2010. http://tede2.pucrs.br/tede2/handle/tede/1567.
Texto completoA nefropatia por contraste (NIC) ? definida como uma piora na fun??o renal que se segue ? administra??o de contraste parenteral, tendo sido exclu?das outras causas. A NIC manifesta-se, usualmente, como uma insufici?ncia renal aguda n?o olig?rica. Por defini??o, deve haver um aumento na creatinina basal de 25-50% ou um aumento superior a 0,5 mg/dl de 24 a 48 horas ap?s o uso vascular de contraste. As medidas de preven??o s?o baseadas na corre??o dos fatores que levam ao desenvolvimento da NIC e dividem-se em: escolha de agentes de contrastes menos nefrot?xicos (n?o-i?nicos) e utiliza??o de doses menores; melhora no estado cl?nico do paciente com hidrata??o; uso de drogas que reduzam vasoconstri??o renal e estresse oxidativo; e suspens?o tempor?ria de drogas com potencial nefrot?xico ou prejudiciais, no caso de diminui??o da filtra??o glomerular. Essa revis?o tem o objetivo de examinar as principais recomenda??es de manejo para prevenir sua ocorr?ncia.
Collaço, Bruno de Barros. "Tomografia de ruído ambiental na Bacia do Paraná". Universidade de São Paulo, 2014. http://www.teses.usp.br/teses/disponiveis/14/14132/tde-04062018-171929/.
Texto completoConventional seismic tomography is known to have poor resolution in regions of low seismicity, therefore, studies carried out in South America did not mapped clearly smaller areas of the continent, for example the region of the Parana basin. To describe the of the crustal structure of the Parana basin, in addition to data obtained by analysis of Andean earthquakes, we used dispersion curves from ambient noise correlation between pairs of seismographic stations, a technique known by Ambient Noise Tomography (ANT). The obtained group velocity maps correspond well with the main geological provinces already known in South America: low velocities under the Andes and sedimentary basins and high velocities in cratonic regions. The high velocity anomalies encountered in the upper mantle, agree with previous studies that confirm the presence of a nucleus in the cratonic basin. However, it is not possible to say whether such a nucleus is intact or not, mainly because previous results showing evidence of the existence of a nucleus divided by suture zones. Nevertheless, surface wave tomography has no resolution to confirm this model. The steps of data processing of this work are well defined and independent, thus, as new stations will being deployed with the advance of BRASIS Project, new paths will be added to the database, increasing the resolution and reliability of the future results.
BAPTISTA, João Júnior. "Tomografia eletromagnética para caracterização de reservatórios de hidrocarbonetos". Universidade Federal do Pará, 2003. http://repositorio.ufpa.br/jspui/handle/2011/5764.
Texto completoRejected by Irvana Coutinho (irvana@ufpa.br), reason: Indexar as palavras-chave on 2014-08-07T13:40:56Z (GMT)
Submitted by Cleide Dantas (cleidedantas@ufpa.br) on 2014-08-18T14:18:12Z No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Tese_TomografiaEletromagneticaCaracterizacao.pdf: 73173380 bytes, checksum: ff9f17b265bec8a1ce1cb29847599a18 (MD5)
Approved for entry into archive by Cleide Dantas (cleidedantas@ufpa.br) on 2014-08-18T14:45:18Z (GMT) No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Tese_TomografiaEletromagneticaCaracterizacao.pdf: 73173380 bytes, checksum: ff9f17b265bec8a1ce1cb29847599a18 (MD5)
Approved for entry into archive by Ana Rosa Silva (arosa@ufpa.br) on 2014-09-18T12:59:53Z (GMT) No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Tese_TomografiaEletromagneticaCaracterizacao.pdf: 73173380 bytes, checksum: ff9f17b265bec8a1ce1cb29847599a18 (MD5)
Made available in DSpace on 2014-09-18T12:59:53Z (GMT). No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Tese_TomografiaEletromagneticaCaracterizacao.pdf: 73173380 bytes, checksum: ff9f17b265bec8a1ce1cb29847599a18 (MD5) Previous issue date: 2003
ANP - Agência Nacional do Petróleo
FINEP - Financiadora de Estudos e Projetos
Na produção de petróleo é importante o monitoramento dos parâmetros do reservatório (permeabilidade, porosidade, saturação, pressão, etc) para o seu posterior gerenciamento. A variação dos parâmetros dinâmicos do reservatório induz variações na dinâmica do fluxo no reservatório, como por exemplo, perdas na pressão, dificultando o processo de extração do óleo. A injeção de fluidos aumenta a energia interna do reservatório e incrementa a pressão, estimulando o movimento do óleo em direção aos poços de extração. A tomografia eletromagnética poço-a-poço pode se tomar em uma técnica bastante eficaz no monitoramento dos processos de injeção, considerando-se o fato de ser altamente detectável a percolação de fluidos condutivos através das rochas. Esta tese apresenta o resultado de um algoritmo de tomografia eletromagnética bastante eficaz aplicado a dados sintéticos. O esquema de imageamento assume uma simetria cilíndrica em torno de uma fonte constituída por um dipolo magnético. Durante o processo de imageamento foram usados 21 transmissores e 21 receptores distribuídos em dois poços distanciados de 100 metros. O problema direto foi resolvido pelo método dos elementos finitos aplicado à equação de Helmhotz do campo elétrico secundário. O algoritmo resultante é válido para qualquer situação, não estando sujeito às restrições impostas aos algoritmos baseados nas aproximações de Born e Rytov. Por isso, pode ser aplicado eficientemente em qualquer situação, como em meios com contrastes de condutividade elétrica variando de 2 a 100, freqüências de 0.1 a 1000.0 kHz e heterogeneidades de qualquer dimensão. O problema inverso foi resolvido por intermédio do algoritmo de Marquardt estabilizado. A solução é obtida iterativamente. Os dados invertidos, com ruído Gaussiano aditivo, são as componentes em fase e em quadratura do campo magnético vertical. Sem o uso de vínculos o problema é totalmente instável, resultando em imagens completamente borradas. Duas categorias de vínculos foram usadas: vínculos relativos, do tipo suavidade, e vínculos absolutos. Os resultados obtidos mostram a eficiência desses dois tipos de vínculos através de imagens nítidas de alta resolução. Os tomogramas mostram que a resolução é melhor na direção vertical do que na horizontal e que é também função da freqüência. A posição e a atitude da heterogeneidade é bem recuperada. Ficou também demonstrado que a baixa resolução horizontal pode ser atenuada ou até mesmo eliminada por intermédio dos vínculos.
In the oil production it important the monitoring of the reservoir parameters (permeability, porosity, saturation, pressure, etc) for its management. Changes in the reservoir dynamic parameters induce variations in reservoir flow, as for example, losses in the pressure, making it difficult the process of extraction of the oil. The fluid injection increases the internal energy and pressure of the reservoir, stimulating the movement of the oil in the direction of the extracting wells. The crosswell electromagnetic method can become in efficient technique in monitoring the injection processes, considering the fact that the percolation of conductive fluid through the sediment is a very sensitive. This thesis presents the results of a very efficient algorithm of electromagnetic tomography applied to synthetic data. The imaging scheme assumes a cylindrical symmetry around a source consisting of a magnetic dipole. During the process of imaging we used 21 transmitters and 21 receivers distributed within two wells 100 meters apart. For the forward problem solution it was used the finite element method applied to the Helmholtz equation for the secondary electric field. It will be demonstrated that the algorithm obtained is not under restrictions imposed by Born and Rytov approximations, therefore, the algorithm can be efficiently applied for any situation as a electric conductivity contrasts as large as 2 to 100, frequencies as 0.1 to 1000.0 kHz and scatterers of any dimensions. The inverse problem was solved using the stabilized Marquardt scheme. This scheme employs a technique that seeks the solution iteratively. The inverted synthetic data, with added Gaussian noise, are the magnetic vertical component, separated in its respective real (in-phase) and imaginary (quadrature) parts. Without constrains, the inverse tomography problem is totally unstable. To stabilize the inverse solution, absolute and relative constraints have been used. The use of these constraints allows producing high definition images. The results show that the resolution is better in the vertical direction than the horizontal and it is also a function of source operating frequency. The position and attitude of the target are recovered well. These results show that constraints can attenuate or eliminate the poor resolution.
Diniz, Kessya Dantas. "Protocolo assistencial para pacientes submetidos a tomografia computadorizada". PROGRAMA DE P?S-GRADUA??O EM ENFERMAGEM, 2016. https://repositorio.ufrn.br/jspui/handle/123456789/22533.
Texto completoApproved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2017-03-29T23:20:22Z (GMT) No. of bitstreams: 1 KessyaDantasDiniz_TESE.pdf: 11488560 bytes, checksum: c749f2ac40a688c78b0e6cbe40b8be53 (MD5)
Made available in DSpace on 2017-03-29T23:20:22Z (GMT). No. of bitstreams: 1 KessyaDantasDiniz_TESE.pdf: 11488560 bytes, checksum: c749f2ac40a688c78b0e6cbe40b8be53 (MD5) Previous issue date: 2016-12-01
O protocolo assistencial caracteriza-se por ser um conjunto de informa??es apresentado de forma dinamizada, que proporciona o cuidado sistematizado, e tem como intuito avaliar de maneira uniformizada os fatores relacionados aos aspectos cl?nicos, epidemiol?gicos e assistenciais, corroborando para a qualidade de vida e seguran?a do paciente. Diante disso, a elabora??o de um protocolo assistencial multiprofissional no ?mbito do servi?o de tomografia computadorizada poder? contribuir para uma avalia??o cl?nica precisa. Este estudo teve como objetivo elaborar e validar um protocolo assistencial no setor de tomografia computadorizada. Trata-se de uma pesquisa metodol?gica com abordagem quantitativa, realizada em duas etapas: a primeira constou de uma revis?o integrativa de literatura que subsidiou a constru??o do protocolo; a segunda caracterizou-se pela valida??o de conte?do por meio de especialistas de diversas profiss?es utilizando a t?cnica Delphi. A pesquisa foi iniciada ap?s a aprova??o do CEP da Universidade Federal do Rio Grande do Norte com o Certificado de Apresenta??o para Aprecia??o ?tica (CAAE) n?. 41872215.7.0000.5537. A primeira etapa foi operacionalizada entre outubro e novembro de 2015, por meio da revis?o da literatura nas bases de dados MEDLINE, SCOPUS, WEB OF SCIENCE e CINAHL, com o cruzamento dos descritores controlados: Diagn?stico por Imagem; Seguran?a do paciente e Tomografia. A amostra foi constitu?da por 23 artigos. Os resultados foram organizados em tr?s categorias: otimiza??o, monitoramento, qualidade e prote??o em rela??o ?s doses de exposi??o ? radia??o; rea??es adversas e nefropatias relacionadas ao uso do contraste; cuidados de enfermagem, gest?o e casos espec?ficos. Para a segunda etapa, os especialistas foram selecionados por meio da Plataforma Lattes do Conselho Nacional de Desenvolvimento Cient?fico e Tecnol?gico (CNPQ), para identificar profissionais de sa?de do Brasil que atuassem como especialistas do instrumento. A amostra foi de 54 especialistas tanto no Delphi 1 como para o Delphi 2. A an?lise estat?stica foi realizada utilizando-se ?ndices de alfa Cronbach, ?ndice de Validade de Conte?do (IVC) e o ?ndice Relativo (IRA). Na primeira etapa, Delphi 1 a m?dia do alfa de Cronbach e IRA foram superiores a 0,80, o IVC foi de 0,924. Na fase Delphi 2, o alfa de Cronbach chegou a 0,868, com IVC de 0,934. Realizou-se uma compara??o entre as fases Delphi 1 e 2, e em ambas a confiabilidade foi bastante satisfat?ria. Atrav?s do teste de Mann-Whitney, observaram-se evid?ncias de diferen?a estat?stica da fase Delphi 1 com a fase Delphi 2 nas dimens?es de utilidade/pertin?ncia, consist?ncia, clareza, atualiza??o, precis?o, sequ?ncia instrucional dos t?picos e na avalia??o geral, onde obteve-se melhor avalia??o na fase Delphi 2 nas vari?veis descritas acima. Assim, alcan?ou-se a validade do protocolo em seu conte?do.
The clinical protocol is characterized by being a set of information presented in a streamlined manner, which provides systematic care, and has as aim to evaluate in a standardized manner the factors related to clinical, epidemiological and supportive aspects, corroborating for the patient's quality of life and safety. At that, the preparation of a multi professional assistance protocol under the computed tomography service can contribute to an accurate clinical evaluation. This study aimed to prepare and validate a supportive protocol in the field of computed tomography. This is a methodological research with a quantitative approach, carried out in two stages: the first consisted of an integrative review of literature that subsidized the construction of the protocol; the second was characterized by the content validation through experts of various professions using the Delphi technique. The research was initiated after approval by the Ethics Committee in Research from the Federal University of Rio Grande do Norte, with the Presentation Certificate for Ethics Assessment CAAE N?. 41872215.7.0000.5537. The first phase was implemented between October and November of 2015, through literature review in the MEDLINE, Scopus, Web of Science and CINAHL databases, with a cross-check of the controlled descriptors: Diagnostic Imaging; Patient safety and Tomography. The sample consisted of 23 articles. The results were organized in three categories: optimization, monitoring, quality and protection in relation to radiation exposure doses; adverse reactions and kidney diseases related to the use of contrast; nursing care, management and specific cases. For the second phase, experts were selected through the Lattes platform of the National Scientific and Technological Development Council (CNPQ) to identify health professionals from Brazil who decided to act as experts. The sample was of 54 experts both in Delphi 1 as for Delphi 2. Statistical analysis was performed using Cronbach's alpha index, Content Validity index (CVI) and the Relative Index (ARI). In the first stage, Delphi 1 the average of Cronbach's alpha and IRA were over 0.80, the CVI was 0.924. In Delphi 2 phase, the Cronbach's alpha reached 0.868, with CVI of 0.934. A comparison was made between Delphi phases 1 and 2, and in both cases the reliability was satisfactory. Through the Mann-Whitney test, we observed evidence of statistical differences between Delphi phase 1 and phase 2 in the dimensions of utility/relevance, consistency, clarity, update, precision, instructional sequence of topics and general evaluation, where we obtained a better evaluation in the Delphi phase 2 variables described above. Thus, it was reached the validity of the protocol in this content.
Yevseyeva, Olga. "Modelagem computacional de tomografia com feixe de prótons". Universidade do Estado do Rio de Janeiro, 2009. http://www.bdtd.uerj.br/tde_busca/arquivo.php?codArquivo=956.
Texto completoNessa tese foi feito um estudo preliminar, destinado à elaboração do programa experimental inicial para a primeira instalação da tomografia com prótons (pCT) brasileira por meio de modelagem computacional. A terapia com feixe de prótons é uma forma bastante precisa de tratamento de câncer. Atualmente, o planejamento de tratamento é baseado na tomografia computadorizada com raios X, alternativamente, a tomografia com prótons pode ser usada. Algumas questões importantes, como efeito de escala e a Curva de Calibração (fonte de dados iniciais para planejamento de terapia com prótons), foram estudados neste trabalho. A passagem de prótons com energias iniciais de 19,68MeV; 23MeV; 25MeV; 49,10MeV e 230MeV pelas camadas de materiais variados (água, alumínio, polietileno, ouro) foi simulada usando códigos Monte Carlo populares como SRIM e GEANT4. Os resultados das simulações foram comparados com a previsão teórica (baseada na solução aproximada da equação de transporte de Boltzmann) e com resultados das simulações feitas com outro popular código Monte Carlo MCNPX. Análise comparativa dos resultados das simulações com dados experimentais publicados na literatura científica para alvos grossos e na faixa de energias de prótons usada em medidas em pCT foi feita. Foi observado que apesar de que todos os códigos mostram os resultados parecidos alguns deslocamentos não sistemáticos podem ser observados. Foram feitas observações importantes sobre a precisão dos códigos e uma necessidade em medidas sistemáticas de frenagem de prótons em alvos grossos foi declarada.
In the present work a preliminary research via computer simulations was made in order to elaborate a prior program for the first experimental pCT setup in Brazil. Proton therapy is a high precise form of a cancer treatment. Treatment planning nowadays is performed basing on X ray Computer Tomography data (CT), alternatively the same procedure could be performed using proton Computer Tomography (pCT). Some important questions, as a scale effect and so called Calibration Curve (as a source of primary data for pCT treatment planning) were studied in this work. The 19.68MeV; 23MeV; 25MeV; 49.10MeV e 230MeV protons passage through varied absorbers (water, aluminum, polyethylene, gold) were simulated by such popular Monte Carlo packages as SRIM and GEANT4. The simulation results were compared with a theoretic prevision based on approximate solution of the Boltzmann transport equation and with simulation results of the other popular Monte Carlo code MCNPX. The comparative analysis of the simulations results with the experimental data published in scientific literature for thick absorbers and within the energy range used in the pCT measurements was made. It was noted in spite of the fact that all codes showed similar results some nonsystematic displacements can be observed. Some important observations about the codes precision were made and a necessity of the systematic measurements of the proton stopping power in thick absorbers was declared.
Carramate, Lara Filipa das Neves Dias. "Utilização da MHSP para aplicação à tomografia computarizada". Master's thesis, Universidade de Aveiro, 2010. http://hdl.handle.net/10773/9786.
Texto completoO presente trabalho centra-se no desenvolvimento e caracterização de um novo sistema de tomografia computorizada baseado na microestrutura MHSP. A tomografia computorizada é uma modalidade imagiológica de uso corrente nos dias de hoje, sendo de extrema utilidade em diagnóstico clínico. Esta modalidade da imagiologia permite obter imagens seccionais das estruturas em estudo, e, além disso, permite a sua reconstrução tri-dimensional. A MHSP é um dispositivo de contagem de fotão único que permite detectar fotões X ou γ conhecendo a sua posição de interacção bem como a energia individual de cada um. Conjugando a informação em posição com a informação em energia é possível criar três tipos de imagens com diferentes ponderações em energia: integrating, counting e Energy Weighting Technique. A imagem integrating é aquela actualmente mais utilizada nos sistemas de diagnóstico médico e traduz a integração da carga que chega ao detector num determinado local. A imagem counting corresponde à contagem dos fotões que chegam a um determinado local do detector. Na reconstrução da imagem Energy Weighting Technique a contribuição de cada fotão é ponderada segundo um factor de 1/E3, onde E é a energia do fotão. O emprego das técnicas counting e EWT representam uma melhoria na qualidade da imagem relativamente à integrating, nomeadamente no que respeita ao contraste, só conseguida com contagem de fotão. A Energy Weighting Technique mostra-se mais poderosa que a counting e é, por isso, de grande interesse. A utilização da MHSP em tomografia computorizada apresenta-se como uma mais-valia devido às suas características de contagem de fotão único.
This work focuses on the development and characterization of a new computed tomography system based on MHSP. The computed tomography is an imaging modality in common use in our days, being extremely useful in clinical diagnoses. This imaging modality allows the acquisitions of sectional images and the tri-dimensional reconstruction of structures in study. The MHSP is a single photon counting device that allows the detection of X and γ photons knowing the interaction position and their individual energy. Combining the position interaction information and energy information the creation of three types of images with different energy weightings is possible: integrating, counting and Energy Weighting Technique. The first is the one most actually used in medical diagnostic systems and is the integration of the total charge that arrives to the detector in a given location. The counting image reflects the number of photons in a specific location of the detector. In image reconstruction of Energy Weighting Technique image the contribution of each single photon is weighted by a factor of 1/E3, with E the photon energy. The application of the Energy Weighting Technique and counting techniques represent an improvement in image quality relatively to integrating image, particularly with respect to the contrast, only achieved with photon counting. The Energy Weighting Technique is more powerfull than the counting technique, being of great interest. The use of MHSP in computed tomography is an asset due to her characteristics of single photon counting.
Silva, José Silvestre Serra da. "Segmentação pulmonar em estudos de tomografia axial computorizada". Doctoral thesis, Universidade de Aveiro, 2005. http://hdl.handle.net/10773/4997.
Texto completoA Tomografia Axial Computorizada (TAC) é um dos meios complementares de diagnóstico médico mais eficiente no estudo das regiões pulmonares. Os métodos de segmentação pulmonar em imagens produzidas por esta modalidade são necessários sempre que se pretenda determinar áreas ou volumes, ou obter informação densitómetria; podem ainda ser integrados no pré-processamento de uma aplicação que envolva a visualização dos pulmões. No âmbito deste trabalho foram desenvolvidos três métodos de segmentação pulmonar, baseados na análise da distribuição dos níveis de cinzento da imagem de TAC da região torácica e na utilização de técnicas morfológicas, bem como no conceito de contornos activos. O método que produziu melhores resultados demonstrou ser capaz de localizar a zona de separação dos pulmões quando estes se encontram visualmente sobrepostos. Foi ainda desenvolvido um método com uma abordagem tridimensional, que processa em simultâneo a informação relativa a todas as secções do exame, e apresenta como principais vantagens a facilidade de identificação da traqueia e brônquios, bem como de múltiplas zonas de contacto entre pulmões. O desempenho como detector de contornos pulmonares, do melhor dos três primeiros métodos de segmentação desenvolvidos, e na ausência de ground truth, foi comparado com o desempenho de seis radiologistas. Também o método de segmentação tridimensional foi avaliado. Além da segmentação dos pulmões, também a segmentação de estruturas pulmonares se torna necessária quando se pretende quantificar áreas e volumes ou ainda proceder a medições densitómetrias dessas estruturas; o que pode ser utilizado no diagnóstico e seguimento de várias patologias como o enfisema bolhoso, que se caracteriza pela presença de bolhas de ar nos pulmões. Sendo assim, foram desenvolvidos três métodos de segmentação para detectar estas bolhas: o primeiro método processa os dados secção a secção e avalia a coerência longitudinal, o segundo utiliza um threshold global e operações morfológicas em 3D e o terceiro utiliza uma versão modificada do modelo deformável level-set tridimensional. Na segmentação de bolhas de ar pulmonares, que apresentam níveis de cinzento muito baixos, o ruído torna-se um problema relevante, sobretudo se as imagens corresponderem a exames de TAC de alta resolução. Assim, para atenuar o ruído das imagens, foi utilizado um conjunto de filtros e estudada a sua influência nos resultados produzidos pelos métodos de segmentação desenvolvidos. Este estudo foi realizado sobre imagens sintetizadas e imagens reais contendo bolhas naturais e artificiais a que se adicionou ruído. Finalmente, e no sentido de ilustrar a utilidade dos métodos propostos, descreve-se um exemplo de uma aplicação que permite discriminar e quantificar as zonas enfisematosas dos pulmões, bem como visualizá-las secção a secção e tridimensionalmente.
X-ray Computed Tomography (CT) is one of the most efficient medical diagnosis tools and has currently a widespread usage in the study of the pulmonary region. Lung segmentation methods are necessary to compute areas or volumes or to perform densitometry; they can also be used as a pre-processing task in pulmonary visualization. In this work, three segmentation methods based on the gray level distribution analysis of CT thoracic images, morphologic techniques and active contours were developed. The method that produced best results proved to be able to locate lung boundaries even when lungs are visually superimposed on the images. Another pulmonary segmentation method using a tridimensional approach was developed; this method processes simultaneously information concerning all sections of the CT exam and has the main advantages of an easy identification of trachea and bronchi, as well as detection of multiple contact zones between lungs. Due to the lack of a ground truth, the performance of the best of the first three segmentation methods was compared with the performance of six radiologists. The tridimensional method was also evaluated. Not only the lung segmentation, but also the segmentation of pulmonary structures is needed for diagnosis and follow-up of a variety of diseases, as it is the case of the bulbous emphysema, characterized by the presence of air bubbles inside the lungs. Thus, three segmentation methods were developed to detect these bubbles, the first method processes the exam section by section and analysis longitudinal coherence, the second method uses a 3D approach with a global threshold and morphologic operations, and the third method uses a modified version of the 3D level-set deformable model. Since air bubbles have very low gray levels, noise becomes a relevant problem in their segmentation, especially in high resolution CT exams. Therefore, to reduce noise, several filters were used and their influence on the results produced by the segmentation methods was analyzed. This study was performed using synthesized and real images with natural and artificial air bubbles, to which noise was added. Finally, and to illustrate the usefulness of the proposed methods, an application was developed that allows discriminating and quantifying pulmonary emphysematous regions, as well as visualizing those regions section by section and tridimensionally.
FSE
PRODEP III
Fundação Calouste Gulbenkian
Fundação Luso-Americana para o Desenvolvimento
Casanova, Luis Ramón. "Algoritmos inversos para problemas mal postos em tomografia". Doctoral thesis, Universidade de Aveiro, 2004. http://hdl.handle.net/10773/18807.
Texto completoEsta tese está dedicada ao estudo de diferentes aspectos da Tomografia de Indução Magnética (TIM), a modalidade mais recente da tomografia eléctrica. A visualização de distribuições espaciais das propriedades eléctricas / magnéticas em sistemas tão diversos como o corpo humano, o interior da terra ou o interior de um tubo, através da medição do campo na sua periferia, tem recebido muita atenção nos últimos 25 anos. Uma dificuldade relacionada com este tipo de técnicas é que o processo de criação da imagem está relacionado com a solução de um problema inverso que é mal posto e não linear, o que significa a falta de unicidade ou estabilidade da solução para um conjunto fixo de dados. Neste trabalho, propõe-se um modelo analítico da TIM que nos permite estudar a natureza do processo tomográfico. Este modelo foi usado para simular e comparar diferentes estratégias de recolha de dados, estudar a má postura do problema, obter gráficos do campo magnético e como um meio de teste de algoritmos de reconstrução. As técnicas de regularização são amplamente conhecidas em diferentes campos como ferramentas poderosas para lidar com a má postura dos problemas inversos. Foram implementados vários destes métodos e avaliada a sua eficácia na geração de imagens com dados simulados e reais. Um método especialmente interessante é um método, chamado ARTUR, que se baseia na preservação das regiões de gradiente acentuado da distribuição e que foi aplicado pela primeira vez em tomografía eléctrica com resultados muito positivos. O impacto da não negatividade como fonte de regularização foi igualmente estudada. Finalmente, foi desenvolvido um algoritmo quantitativo não linear de estimação de paramétrica.
This thesis is dedicated to the study of Magnetic Induction tomography (MIT) the more recent modality of electrical imaging. Tomographic techniques based on electrical measurements taken from outside to probe the interior of quite different systems like can be the human body, the subsurface of the earth or the flow inside an industrial pipe line have received a lot of attention in the last 25 years. One challenge posed by this kind of techniques is that the imaging process is related to the solution of a strongly ill-posed and non-linear inverse problem that often means the lack of uniqueness or stability of the solution for a given data set. In this work an MIT analytical model is proposed that will allow us to study the nature of the tomographic process through the evaluation of its ill-posedness. It is used to simulate and compare different data collection strategies, to study the invertibility of the problem, to obtain graphical views of the field and as a framework to test inversion algorithms. Regularization techniques are widely spread in different fields as powerful tools to deal with ill-posed problems. We have implemented several of these methods and tested their effectiveness with simulated and real data as well. Specially, an edge-preserving technique called ARTUR has been applied for the first time in electrical tomography with encouraging results. The impact of the non-negativity as a source of regularization when incorporated in the inversion procedures has been studied and quantified. Finally, it has been developed a quantitative algorithm for MIT parameter estimation.
Silva, Flávia Daniela da. "Processamento e análise em tomografia computorizada pulmonar: pneumonia". Master's thesis, Universidade de Aveiro, 2017. http://hdl.handle.net/10773/21182.
Texto completoA Tomografia Computorizada (TC) representa a modalidade imagiológica mais eficiente no estudo das regiões pulmonares. Os métodos para a segmentação pulmonar são ferramentas essenciais para a análise de imagens de TC pulmonar, pois permitem a avaliação de parâmetros quantitativos, que podem ter grande interesse na avaliação de patologias pulmonares e impactos de intervenções terapêuticas, nomeadamente em pneumonia. As técnicas de fisioterapia respiratória têm sido exploradas como um complemento ao tratamento de pneumonia, no entanto é ainda um assunto bastante controverso e em investigação. De entre as inúmeras abordagens para a segmentação pulmonar existentes, a maioria não funciona adequadamente na presença de condição patológica moderada a severa. Assim, os principais objetivos deste projeto de investigação consistiram no desenvolvimento de uma rede de processamento e análise de imagem, utilizando a plataforma MeVisLab, para a segmentação automática da árvore brônquica (AB) e do parênquima pulmonar, em exames de TC pulmonar de pacientes com pneumonia. A rede foi utilizada para obter o volume e a densidade do parênquima pulmonar numa amostra de 33 pacientes com diagnóstico de pneumonia, com o objetivo de averiguar qual o impacto das técnicas de fisioterapia respiratória na condição clínica dos pacientes submetidos a esta abordagem terapêutica. Todos os pacientes realizaram duas TC pulmonares, uma de caráter urgente e outras após três semanas de tratamento, sendo que este consistiu numa terapêutica conservadora farmacológica (grupo de controlo) ou na conjugação desta última com fisioterapia respiratória (grupo experimental). A rede MeVisLab desenvolvida conjugou alguns métodos de segmentação pulmonar, nomeadamente o método de Region Growing 3D e o método baseado no registo, que foi utilizado na segmentação pulmonar de casos clínicos com achados imagiológicos severos, em que o método de Region Growing 3D se revelou ineficaz. Além disto, o método de segmentação baseado no registo foi validado numa amostra de 15 pacientes nos quais era possível aplicar os dois métodos de segmentação. Todos os dados recolhidos neste projeto foram analisados estatisticamente, sendo aplicado o teste da ANOVA de dois fatores mistos para avaliar os efeitos das intervenções terapêuticas na amostra em estudo e o teste t-Student para a validação do método baseado no registo. Os resultados obtidos sugerem que a fisioterapia respiratória é uma abordagem terapêutica eficiente e viável na gestão de pacientes com pneumonia, principalmente ao nível das caraterísticas imagiológicas da AB, e que o método baseado no registo permitiu a obtenção de resultados de segmentação tão fiáveis como os resultados de segmentação obtidos pelo método de Region Growing 3D.
Computed Tomography (CT) represents the most efficient imaging modality in the study of pulmonary regions. Methods for the pulmonary segmentation are essential tolls for the analysis of pulmonary CT images because they allow the evaluation of quantitative parameters which can be extremely important in the evaluation of pulmonary diseases and therapeutic interventions, such as pneumonia. The respiratory physiotherapy techniques have been implemented as a complementary intervention in pneumonia, however this is controverse and is under and investigation. Among the many approaches to the lung segmentation, most of them don´t work correctly in the presence of a moderate to severe pathological condition. Thus, the main objectives of this project were the development of an image processing and an analysis network using the MeVisLab platform for the automatic segmentation of the bronchial tree and the pulmonary parenchyma, in pulmonary CT scans of patients with pneumonia. Then, the respective quantitative parameters were extracted (volume and density) to determinate the impact of respiratory physiotherapy on de clinical condition of patients submitted to this therapeutic approach. This project included 33 patients with suspected pneumonia, who performed two pulmonary CT, the first of the urgent character and the other three weeks after de treatment, which consisted in a conservative pharmacological therapy (control group) or a combination on this latter with the respiratory physiotherapy (experimental group). The MeVisLab network combined some methods for the lung segmentation, principally the Region Growing 3D and registration methods. The last method was used in the pulmonary segmentation of clinical cases with severe imaging findings, in which the Region Growing 3D was inefficient. In addition, these two methods were applied in a set of 15 patients in order to test the similarity between both. All the data of these project were statistically analyzed, being applied the ANOVA two way to evaluate the effects of the therapeutics interventions in the sample patients and the Student t-test for the validation of the method based on registration. The results obtained suggested that respiratory physiotherapy seems an efficient and viable therapeutic in the management of patients with pneumonia, mainly at the level of bronchial tree imaging features, and that the method based on registration allowed to obtain segmentation results as reliable as the segmentation results obtained with the standard method.
Cardi, Riccardo. "Tomografia da analisi di rumore sismico nell'Italia settentrionale". Master's thesis, Alma Mater Studiorum - Università di Bologna, 2015. http://amslaurea.unibo.it/8347/.
Texto completoDoiche, Danuta Pulz. "Estudo tomográfico do encéfalo de cães dolicocefálicos, mesaticefálicos e branquicefálicos clinicamente sadios /". Botucatu : [s.n.], 2011. http://hdl.handle.net/11449/88996.
Texto completoBanca: Masao Iwasaki
Banca: Rogério Martins Amorim
Resumo: A Tomografia Computadorizada (TC), juntamente com a Ressonância Magnética, são modalidades de diagnóstico por imagem avançadas, consideradas de escolha para a avaliação do sistema nervoso, por fornecerem imagens livres de sobreposições e detectarem pequenas diferenças de densidade tecidual. Dentro de qualquer estudo, o conhecimento das possíveis formas de apresentação de cada estrutura e a determinação do limite entre o fisiológico e o alterado são fundamentais para um estudo preciso. O presente trabalho teve como objetivo a descrição dessas variações nas imagens tomográficas do encéfalo, no que diz respeito aos ventrículos laterais e atenuação do parênquima encefálico e cerebelar entre os grupos aqui estipulados (grupo dolicocefálico composto por cães pastores Alemães, grupo mesaticefálico composto por Rottweilers e grupo braquicefálico compostos por cães da raça Boxer) e assim enriquecer a avaliação cerebral à TC e minimizar erros de interpretação. Foram detectadas diversas diferenças individuais e entre os grupos à avaliação qualitativa. Quantitativamente, houve diferença da altura ventricular entre os braquicefálicos e os demais, mostrando que ainda não é possível apenas uma faixa de valores da altura ventricular comum a todos os cães, e que, para as raças braquicefálicas o valor da razão da altura ventricular e encefálica até 25% pode servir como limite superior nos animais hígidos. Os valores de atenuação finais na fase pré-contraste são compatíveis com trabalhos anteriores, o bulbo olfatório e o cerebelo apresentaram-se diferentes estatisticamente em relação aos demais locais. A única raça que teve nas fases simples e contrastada diferenças estatísticas em todos os locais foram os animais do grupo B
Abstract: Computed tomography (CT) along with Magnetic Ressonance Imaging (MRI) are diagnostic imaging modalities of advanced, considered choice for the evaluation of the nervous system, for providing free images overlap and detect small differences in tissue density. Within any study, knowledge of the possible forms of presentation of each structure and determining the limit between physiological and change are fundamental to a precise study. This study aimed to describe these variations in the tomographic images of the brain, with respect to the lateral ventricles and attenuation of brain parenchyma and cerebellum between the groups set forth herein (dolichocephalic group composed of German shepherd dogs, a group composed of rottweilers and mesaticephalic brachycephalic group consisting of Boxer dogs) and thus enrich the evaluation of brain CT and minimize misunderstandings. We detected several differences between individuals and groups in the qualitative assessment of the aspects mentioned. Quantitatively, there were differences between the ventricular height between brachycephalic and others, showing that it is not possible just a strip of ventricular height values common to all dogs, and that for brachycephalic breeds the value of 25% can serve as upper limit in healthy animals. The final attenuation values in the pre-contrast are consistent with previous works, the olfactory bulb and cerebellum were different statistically when compared to other locations. The only race that was simple and contrasted phases statistical differences in all sites were the animals in group B
Mestre
Carlini, Gianluca. "Artefatti di ricostruzione nella tomografia computerizzata con raggi X". Bachelor's thesis, Alma Mater Studiorum - Università di Bologna, 2018. http://amslaurea.unibo.it/16933/.
Texto completoBroquetas, Antoni. "Tomografia de microondas en geometria cilindrica para aplicaiones biomédicas". Doctoral thesis, Universitat Politècnica de Catalunya, 1989. http://hdl.handle.net/10803/5889.
Texto completoFriggieri, Simone. "Applicazione della tomografia computerizzata con raggi X alla dendrocronologia". Bachelor's thesis, Alma Mater Studiorum - Università di Bologna, 2021. http://amslaurea.unibo.it/22955/.
Texto completoRollo, Luciana Cavalcante Pereira. "Tomografia de impulso para estimativa da densidade da madeira". Universidade de São Paulo, 2010. http://www.teses.usp.br/teses/disponiveis/11/11150/tde-16032010-170802/.
Texto completoThere are several techniques which use the passage of waves through wood to obtain information. Among them the tomography of trees is emphasized, reconstructing cross sections of trunk and branches. The impulse tomography is based on the timing of mechanical sound wave travelling between sensors attached to a cross section of the tree, to compute wave speed and construction of the tomographic image. It is known that the speed of the passage of mechanical waves is determined by the phisical and mechanical properties of the wood. Specially, eslasticity module, density and moisture content. Until this moment, there are several studies about the correlation between wave speed (mainly ultrasound) and elasticity module. The studies presented next are highlighted because they evaluate the correlation between mechanical wave speed, obtained by impulse tomography, and wood density, with the intention to use it as a tool to estimate density. The several estabilished methods for determining wood density are characterized by using wood samples, in many cases, difficult to obtain. Besides being performed using laboratory procedures which may take even weeks. Therefore, in chapter 2, Physical concepts involved in the impulse tomography method and the relationship with apparent density, there are considerations about physical concepts that explain the behavior of mechanical waves and present the correlation found between mechanical wave speed and apparent density, with 12% moisture content of the wood, to three species of wood with different densities (Schizolobium parahyba (Vell.) Blake - Guapuruvu, Eucalyptus saligna Sm. - Eucalipto, Caesalpinia echinata Lam. Pau-Brasil). The results were very satisfying, since the coeficient of determination - R2 the general equation mechanical wave speed at 12% =514,89 * apparent density at 12% + 312,49 was equal to 0,9284, highly significant regarding F test at 1%. In chapter 3, Impulse tomography for the estimation of basic wood density of live trees, statistical models for estimation are presented to estimate basic wood density in live trees, using mechanical wave speed. Data was collected from trees of 10 native species. The accuracy measurements (coeficient of determination R2, mean percentual error EMP, and random error i) ensure the utility of the models.
Pereira, Lenon Mendes. "Caracterização do MOSFET MOskin para dosimetria em tomografia computadorizada". Universidade Federal de Pernambuco, 2015. https://repositorio.ufpe.br/handle/123456789/14936.
Texto completoMade available in DSpace on 2016-01-19T18:10:45Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Lenon Mendes Dissertacao Mestrado 2015.pdf: 3797605 bytes, checksum: 7022202de7a4af31595ea4374ab76da7 (MD5) Previous issue date: 2015-05-29
CAPES
Este trabalho visa caracterizar o MOSkin para dosimetria em tomografia computadorizada. Desta forma, a resposta do detector foi avaliada para as qualidades de referência RQT 8, RQT 9 e RQT 10 e estudos foram realizados para avaliar a sensibilidade, dependência energética, reprodutibilidade, desvanecimento e dependência angular da resposta do dosímetro. Em seguida, o dosímetro foi empregado para avaliação do kerma ar em um tomógrafo Philips Brilliance 6 CT e o seu desempenho foi comparado com o filme radiocrômico Gafchromic XR-CT, dosímetros termoluminescentes TLD-100 e uma câmara de ionização tipo lápis. Os resultados mostraram que a resposta do dosímetro é linear e reprodutível dentro da faixa de dose escolhida (até 7 cGy). Para as energias de feixe avaliadas, o fator de correção para a dependência energética variou no máximo 15% e a dependência angular foi inferior à 7,78% na faixa de 0 a 90º. Assim como esperado, a sensibilidade do dosímetro declinou com o histórico de dose. Para um MOSkin irradiado com a qualidade de feixe RQT 9 (120 kV) a sensibilidade no final da vida útil era 4,76% menor do que a sensibilidade inicial. Porém, com o uso do processo de annealing por pulsos de corrente, foi possível recuperar a resposta do MOSkin, tornando-o reutilizável. Por fim, os resultados obtidos no tomógrafo mostraram que o MOSkin é adequado para obtenção da distribuição do kerma no ar em tomografia computadorizada e para a avaliação da Dose Total Acumulada no Centro.
The aim of this research was to characterize the response of the MOSkin dosimeter for x-ray Computed Tomography beams. The dosimeter’s response was evaluated for standard radiation qualities RQT 8, RQT 9 and RQT 10 and experiments were performed to investigate the sensitivity, energy dependence, reproducibility, fading and angular dependence of the response for the device. The MOSkin was also used for kerma air evaluation in a Philips Brilliance 6 CT unit and a comparison was made with TLD-100 thermoluminescents dosimeters, a radiochromic film Gafchromic XR-CT and a pencil ionization chamber. The results have shown that the MOSkin response was linear and reproducible within the kerma air range used in this research (until 7cGy). Energy dependence correction factors varied up to 15% among the tested x-ray energies. Angular dependence of the dosimeter was not greater than 7.78% within the angle range from 0 to 90 degrees. As expected, the MOSkin sensitivity was found to decline with the dose history. For a MOSkin irradiated at a tube potential of 120 kVp (RQT 9) the sensitivity at its end live was 4.76% smaller than the sensitivity at the beginning of its lifetime. Also, pulsed current annealing was proved to be successful for recovering the threshold voltage and sensitivity. At last, the MOSkin is proved a good alternative for the CT air kerma profile measurements and was adequate for the Total Accumulated Dose assessment.
Senzako, Edna Yoshiko. "SisMatch - Matching para Imagens de Tomografia por Ressonância Magnética". Universidade de São Paulo, 1996. http://www.teses.usp.br/teses/disponiveis/55/55134/tde-28082017-091429/.
Texto completoThis work presents a study of image matching. Image matching can be used to evaluate the similarþ between objects in different images, to detect change between scenes, to calculate movement of objects and to compile information from different kind of images. This project was based on a theoretical study of matching, the implementation of SísMatch - System of Matching and the analysis of perfonnance of the -matching methods. The images are delivered by the Magnetic Resonance tomograph under development at Physics Institute at São Carlos - USP.
Vaz, Carlos Manoel Pedro. "Tomografia computadorizada aplicada a estudos de compactação de solos". Universidade de São Paulo, 1989. http://teses.usp.br/teses/disponiveis/11/11133/tde-20181127-155416/.
Texto completoThe soil compaction problem was studied using a first generation computed tomography scanner (CT). This apparatus gets images of soil cross sections samples, with resolution of a few millimeters. We performed the following laboratory and field experiments: a) Basic experiments of equipment calibrations and resolutions studies. b) Measurements of compacted soil thin layers. c) Measurements of soil compaction caused by agricultural tools. d) Stress-strain modelling in confined soil sample, with several moisture degree. e) Characterizations of soil bulk density profile with samples collected in a hole (trench), comparing with a cone penetrometer technique. The results showed errors in soil bulk density and moisture content around 2% and 3%, for an image with 2 mm of spatial resolution. In compacted soil thin layer studies, was possible identified layers grater than 2 mm. Experiments of compacted soil caused by agricultural tools provided results since zero up to 0.08 g/cm3 of soil bulk density increase, in the sample profile. In the experiment with samples collected in a trench, the results shown a compacted region of 30 cm between 1,3 to 1,5 g/cm3. Measurement with cone penetrometer showed a close dependence with soil moisture content. For dry soils, the cone penetrometer profile was very similar to the soil bulk density measured by CT. Stress-strain modelling studies with confined samples, provided an approximatly linear correlation between soil bulk density and sample length, for 0,8 MPa pressure, for a constant moisture content. Finally, we concluded that the CT can be used in the study of soil compaction problems, with better performance than be traditional techniques.
Bonagamba, Tito Jose. "Seleção de planos em tomografia por ressonância magnética nuclear". Universidade de São Paulo, 1986. http://www.teses.usp.br/teses/disponiveis/54/54132/tde-11092007-155255/.
Texto completoThis work was developed with the purpose of obtaining Tomoqraphic Images by Nuclear Magnetic Resonance (NMR). It was elaborated in two distinct ways. One of them was the analysis of slice selection by selective excitation, already proposed by other authors. To do this, we developed a package of computer programs that simulates the behavior of a spin system from the Bloch Equation solution. The other was the adaptation of a NMR spectrometer already existing in our laboratory to obtain tomographic imaqes. The results show that our prototype can produce imaqes tomographics slices with width less than 1 cm.