Dissertations / Theses on the topic 'Релейний захист'
Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles
Consult the top 39 dissertations / theses for your research on the topic 'Релейний захист.'
Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.
You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.
Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.
Грудина, А. В. "Реконструкція електричної частини підстанції 110/6 кВ". Master's thesis, Сумський державний університет, 2019. http://essuir.sumdu.edu.ua/handle/123456789/76188.
Full textІванов, Олександр Олександрович, Александр Александрович Иванов, Oleksandr Oleksandrovych Ivanov, О. І. Ігнатова та С. О. Іванов. "Моделювання дистанційного захисту лінії електропередач в програмному комплексі PSCAD/EMTDC". Thesis, Сумський державний університет, 2015. http://essuir.sumdu.edu.ua/handle/123456789/41389.
Full textРоденко, В. В. "Розрахунок параметрів та модернізація обладнання підстанції 110/6 кВ "Компресорна"". Master's thesis, Сумський державний університет, 2018. http://essuir.sumdu.edu.ua/handle/123456789/71393.
Full textКоломієць, Н. А. "Реконструкція ПС 35/10 кВ "Городська" АТ "Чернігівобленерго"". Thesis, Чернігів, 2019. http://ir.stu.cn.ua/123456789/19631.
Full textМетою проекту є підвищення ефективності функціонування ПС 35/10 кВ "Городська" АТ "Чернігіволбенерго" за рахунок її реконструкції. Основні задачі, які треба вирішити: перевірити відповідність існуючих схем електроз'єднань Ру 10 та 35 кВ до діючих нормативних документів та, за необхідності, вибрати нові схеми; розрахувати струми короткого замикання та вибрати нове сучасне електрообладнання , розрахувати релейний захист та блискавкозахист підстанції; виконати економічне обгрунтування прийнятих рішень.
Данильченко, А. О. "Аналіз та моделювання режимів роботи гідроелектростанції". Master's thesis, Сумський державний університет, 2021. https://essuir.sumdu.edu.ua/handle/123456789/87259.
Full textСупрун, В. О. "Проектування електропостачання багатоквартирного житлового будинку". Master's thesis, Сумський державний університет, 2018. http://essuir.sumdu.edu.ua/handle/123456789/71235.
Full textКісіль, Н. П. "Аналіз режиму роботи та вибір електричного обладнання підстанції 35/10 кВ". Master's thesis, Сумський державний університет, 2018. http://essuir.sumdu.edu.ua/handle/123456789/71218.
Full textШедна, Світлана Петрівна, та Svitlana Shedna. "Розробка технічних заходів підвищення надійності водогрійної котельні молокозаводу". Master's thesis, ТНТУ імені Івана Пулюя, 2019. http://elartu.tntu.edu.ua/handle/lib/29560.
Full textIn diploma thesis solved the practical problem of increasing the reliability of the power supply system of the boiler room due to the application of technical and organizational measures based on the modernization of electrical equipment and the installation of automatic reserve system. Performed calculations the electrical loads of power and lighting equipment of the boiler room for choice the technical measures to ensure the reliability of work. Performed calculations of the distribution network were made and the switching equipment of the boiler room was selected to ensure the reliability. Installed the automatic backup input device to simplify the relay protection setting and ensure reliability. The organizational and technical measures of increasing the reliability of the boiler room operation are offered.
Вступ …………………………………………………………………………….. 7 1 АНАЛІТИЧНА ЧАСТИНА .………………………………………..…….. 9 1.1 Аналіз системи електропостачання підприємства та технологічного процесу ……….……………………………………… ……………………….… 9 1.2 Аналіз технічних заходів підвищення надійності електропостачання промислових підприємств ……………………………............................……… 13 1.3 Висновки до першого розділу …………………………………………….... 17 2 НАУКОВО-ДОСЛІДНА ЧАСТИНА ………………………………………. 18 2.1 Методика оцінки показників надійності з врахуванням якості електроенергії …………………………………………………………………… 18 2.2 Формалізація методики комплексної оцінки ……………………………… 22 2.3 Аналіз алгоритму комплексної оцінки надійності електропостачання та якості електроенергії ……………………………………………………………. 25 2.4 Висновки до другого розділу ………………………………………………. 29 3 ТЕХНОЛОГІЧНА ЧАСТИНА ………..……………………………………. 30 3.1 Розрахунок навантаження котельні підприємства ….………………….…. 30 3.2 Розрахунок освітлення котельні ……………...………………...……..…... 36 3.3 Висновки до третього розділу ……………………………………………… 43 4 ПРОЕКТНО-КОНСТРУКТОРСЬКА ЧАСТИНА ………………..……… 45 4.1 Розрахунок розподільної мережі та вибір комутаційного обладнання водогрійної котельні …………………………….……………………………… 45 4.2 Вибір захисту мережі водогрійної котельні ……………………..………… 49 4.3 Вибір автоматичного контролю загазованості ………………………..…... 54 4.4 Захист ліній робочого живлення водогрійної котельні …...……...………. 56 4.5 Висновки до четвертого розділу ……………………………………....…… 58 5. СПЕЦІАЛЬНА ЧАСТИНА ………………………………………………… 59 5.1 Аналіз системи автоматичного введення резерву на підприємствах ……. 59 5.2 Вибір схеми автоматичного ввімкнення резерву …………………………. 63 5.3 Автоматичне регулювання коефіцієнта трансформації …………..………. 67 5.4 Висновки до п’ятого розділу ………………...…………………..…....…… 69 6 ОБГРУНТУВАННЯ ЕКОНОМІЧНОЇ ЕФЕКТИВНОСТІ …………..… 71 6.1 Планування системи планово-попереджувальних ремонтів ……..……… 71 6.2 Планування чисельності ремонтно-експлуатаційного персоналу…...…… 73 6.3 Планування кошторису експлуатаційних витрат …………………………. 75 6.4 Планування собівартості передачі і розподілу електроенергії …………... 76 6.5 Заходи щодо зменшення затрат ……………………………………………. 77 7 ОХОРОНА ПРАЦІ ТА БЕЗПЕКА В НАДЗВИЧАЙНИХ СИТУАЦІЯХ 79 7.1 Аналіз потенційних небезпек і шкідливих виробничих факторів ……….. 79 7.2 Забезпечення нормальних умов праці на підприємстві …………………... 80 7.3 забезпечення техногенної безпеки на підприємстві ……………………… 85 8 Екологія ……………………………………………………………………….. 90 8.1 Вплив переробки молочної сировини на навколишнє середовище ….…. 90 8.2 Основні методи очищення стічних вод в молочній промисловості …...... 92 ЗАГАЛЬНІ ВИСНОВКИ ДО ДИПЛОМНОЇ РОБОТИ ………...……….... 95 ПЕРЕЛІК ПОСИЛАНЬ …………………………..…..………………………. 96
Кушнір, Мирослав Васильович, та Myroslav Kushnir. "Розробка технічних заходів зниження втрат електроенергії в системі електропостачання електроцеху машинобудівного заводу". Master's thesis, Тернопільський національний технічний університет імені Івана Пулюя, 2019. http://elartu.tntu.edu.ua/handle/lib/29685.
Full textУ дипломній роботі вирішено практичну проблему зниження технічних втрат електроенергії в системі електропостачання електричного цеху та підприємства в цілому. Проведені дослідження щодо зниження втрат електроенергії на підприємстві. Проведені розрахунки електричних навантажень силових та освітлювальних споживачів електричного цеху та підприємства. Визначено величини необхідної реактивної потужності з енергосистеми в режимах її максимальних навантажень та здійснена компенсація реактивної потужності. Проведені розрахунки струмів короткого замикання та здійснено вибір захисного обладнання. Проведена перевірка кабелів на стороні 10 кВ цехових трансформаторів на термічну стійкість та обґрунтовано зміну площі січення проводів та здійснено вибір вимикачів на сторонах 110 кВ та 10 кВ. Проведений розрахунок релейного захисту трансформаторів головної понижувальної підстанції з вибором обладнання.
ВСТУП …7 1 АНАЛІТИЧНА ЧАСТИНА ...9 1.1 Аналіз технічних заходів зниження втрат електричної енергії промислових підприємств …9 1.2 Загальна характеристика електричного цеху та системи електропостачання машинобудівного заводу …13 1.3 Висновки до першого розділу …15 2 НАУКОВО-ДОСЛІДНА ЧАСТИНА …16 2.1 Моделі керування конденсаторними пристроями …16 2.2 Обґрунтування вибору місця встановлення КП в електричному цеху підприємства …17 2.3 Висновки до другого розділу …22 3 ТЕХНОЛОГІЧНА ЧАСТИНА …23 3.1 Розрахунок електричних навантажень електричного цеху ...23 3.2 Розрахунок освітлювального обладнання електричного цеху …26 3.3 Розрахунок електричних навантажень по підприємству …29 3.4 Розрахунок електричної мережі підприємства …34 3.5 Висновки до третього розділу …38 4 ПРОЕКТНО-КОНСТРУКТОРСЬКА ЧАСТИНА …40 4.1 Розрахунок струмів короткого замикання …40 4.2 Вибір комутаційного та захисного обладнання …44 4.3 Розрахунок релейного захисту трансформаторів ГПП …54 4.4 Висновки до четвертого розділу …60 5. СПЕЦІАЛЬНА ЧАСТИНА …61 5.1 Аналіз видів компенсації реактивної потужності та використання конденсаторних установок …61 5.2 Розрахунок компенсації реактивної потужності та вибір конденсаторних установок …62 5.3 Висновки до п’ятого розділу …69 6 ОБГРУНТУВАННЯ ЕКОНОМІЧНОЇ ЕФЕКТИВНОСТІ...70 6.1 Вибір варіантів трансформаторів ГПП …70 6.2 Техніко-економічне обґрунтування схеми зовнішнього електропостачання підприємства …72 6.3 Розрахунок техніко-економічних показників схем зовнішнього електропостачання за варіантами …80 7 ОХОРОНА ПРАЦІ ТА БЕЗПЕКА В НАДЗВИЧАЙНИХ СИТУАЦІЯХ...82 7.1 Заходи з охорони праці та техніки безпеки на ГПП …82 7.2 Заходи щодо підвищення стійкості роботи трансформаторної підстанції за умов надзвичайних ситуацій …89 8 ЕКОЛОГІЯ …93 8.1 Екологічний безпека машинобудівного комплексу …93 8.2 Методи забезпечення екологічної безпеки підприємств машинобудівної галузі …94 ЗАГАЛЬНІ ВИСНОВКИ ДО ДИПЛОМНОЇ РОБОТИ …97 ПЕРЕЛІК ПОСИЛАНЬ …99
Горщар, Юлія Миколаївна, та Yuliia Horshchar. "Розробка заходів щодо безперебійної роботи електричного обладнання промислового підприємства". Master's thesis, Тернопільський національний технічний університет імені Івана Пулюя, 2020. http://elartu.tntu.edu.ua/handle/lib/33181.
Full textУ кваліфікаційній роботі магістра здійснено розробку заходів щодо безперебійної роботи електричного обладнання промислового підприємства. Подано характеристику електроприймачів підприємства, здійснено: розрахунок електричних навантажень; вибір потужності силових трансформаторів; вибір перерізу живлячих лінії напругою вище 1000 В і до 1000 В; розрахунок струмів короткого замикання, з урахуванням величин струмів короткого замикання проведено вибір обладнання; розрахунок заземляючих пристроїв; розрахунок освітлення будівлі; вибір релейних захистів для електрообладнання. В цілях забезпечення безперебійності живлення електроенергією відповідальних споживачів і підвищення стійкості обладнання по відношенню до струмів короткого замикання передбачається автоматизація в системах електропостачання, що дозволяє обходиться без чергового персоналу на підстанціях
In the qualification work of the master the measures on uninterrupted work of the electric equipment of the industrial enterprise are developed. The characteristic of electric receivers of the enterprise is given, the following is carried out: calculation of electric loads; power selection of power transformers; selection of the cross section of the supply line with a voltage above 1000 V and up to 1000 V; calculation of short-circuit currents, taking into account the values of short-circuit currents, the choice of equipment was made; calculation of earthing devices; calculation of building lighting; selection of relay protections for electrical equipment. In order to ensure uninterrupted power supply to responsible consumers and increase the resistance of equipment to short-circuit currents, automation is provided in power supply systems, which allows to do without regular personnel at substations.
ВСТУП 6 1 АНАЛІТИЧНИЙ РОЗДІЛ 9 1.1 Підвищення надійності схеми електропостачання промислового підприємства 9 1.2 Провали напруги в системах електропостачання підприємств хімічної промисловості 12 1.3 Основні шляхи економії електроенергії на промислових підприємствах 13 1.4 Загальна характеристика технологічного процесу і споживачів електроенергії 15 1.5 Висновки до розділу 1 16 2 РОЗРАХУНКОВО-ДОСЛІДНИЦЬКИЙ РОЗДІЛ 18 2.1 Розрахунок електричних навантажень 18 2.1.1 Метод коефіцієнта використання 18 2.1.2 Розрахунок освітлення 21 2.2 Розрахунок втрат в трансформаторах 21 2.3 Розрахунок і вибір схем живлення і напруги 23 2.3.1 Вартість електроенергії 23 2.3.2 Техніко-економічні розрахунки схем зовнішнього електропостачання 24 2.4 Вибір трансформаторів 6 кВ 38 2.5 Картограма електричних навантажень 40 2.6 Розрахунок струмів короткого замикання 41 2.7 Висновки до розділу 2 44 3 ПРОЕКТНО-КОНСТРУКТОРСЬКИЙ РОЗДІЛ 45 3.1 Вибір обладнання на стороні 6 кВ 45 3.1.1 Вибір ввідних і секційних вимикачів 45 3.1.2 Вибір трансформаторів напруги 46 3.1.3 Вибір трансформаторів струму 47 5 3.1.4 Вибір шин 50 3.1.5 Вибір ізоляторів 52 3.2 Розрахунок мережі низької напруги 53 3.2.1 Вибір автоматичного вимикача на вводі 53 3.2.2 Вибір секційного вимикача 54 3.2.3 Вибір провідникової продукції і захисного обладнання 55 3.3 Освітлення 56 3.3.1 Загальні відомості 56 3.3.2 Розрахунок освітлення відділення класифікації 57 3.4 Релейний захист силового трансформатора 59 3.5 Автоматика електропостачання 60 3.5.1 Автоматичне включення резерву (АВР) 60 3.5.2 Автоматичне повторне включення (АПВ) 61 3.6 Висновки до розділу 3 62 4 ОХОРОНА ПРАЦІ ТА БЕЗПЕКА В НАДЗВИЧАЙНИХ СИТУАЦІЯХ 63 4.1 Електробезпека 63 4.2 Протипожежна безпека на підприємстві 65 4.3 Вимоги до хімічної і промислової безпеки 68 ЗАГАЛЬНІ ВИСНОВКИ 70 ПЕРЕЛІК ПОСИЛАНЬ 72
Каленик, Андрій Анатолійович, та Andrii Kalenyk. "Оптимізація роботи системи електропостачання електромеханічного заводу". Master's thesis, Тернопільський національний технічний університет імені Івана Пулюя, кафедра електричної інженерії,Тернопіль, Україна, 2021. http://elartu.tntu.edu.ua/handle/lib/36690.
Full textУ кваліфікаційній роботі на основі прийнятих критеріїв оптимізації запропоновані технічні рішення щодо оптимальної роботи системи електропостачання підприємства. Проведені розрахунки електричних навантажень на ланках 10 кВ та на РТП 35/10 кВ дозволили збалансувати навантаження на секційних шинах. Запропоновані технічні рішення щодо забезпечення надійності електропостачання на основі вибору захисного обладнання на ланках 10кВ та 35 кВ. Проведені дослідження щодо функціонування силових трансформаторів 10/0,4кВ в різних режимах навантаження для забезпечення надійності.
In the qualification work on the basis of the accepted optimization criteria the technical decisions concerning optimum work of system of power supply of the enterprise are offered. The calculations of electrical loads on 10 kV links and on DTS 35/10 kV allowed to balance the loads on sectional busbars. To ensure technical solutions the reliability of electricity supply based on the choice of protective equipment at 10 kV and 35 kV. Studies on the operation of 10 / 0.4 kV power transformers in different load modes to ensure reliability.
ВСТУП ... 6 1 АНАЛІТИЧНИЙ РОЗДІЛ ... 8 1.1 Вибір критеріїв оптимізації системи електропостачання підприємства ... 7 1.2 Аналіз розподільних ланок системи електропостачання підприємства ... 12 1.3 Висновки по першому розділі ... 16 2 РОЗРАХУНКОВО-ДОСЛІДНИЦЬКИЙ РОЗДІЛ ... 18 2.1 Розрахунок електричних навантажень на ланках 10 кВ ... 18 2.2 Вибір перерізу кабельних ліній ... 22 2.3 Дослідження кількості та потужності силових трансформаторів на ланках 10/0,4 кВ ... 23 2.4 Аналіз та оптимізація компенсації реактивної потужності на підприємстві ... 28 2.5 Дослідження надійності силових трансформаторів при різних режимах роботи ... 30 2.6 Висновки по другому розділі ... 35 3 ПРОЕКТНО-КОНСТРУКТОРСЬКИЙ РОЗДІЛ ... 37 3.1 Розрахунок струмів короткого замикання ... 37 3.2 Вибір захисного електричного обладнання на РП ... 43 3.3 Техніко-економічне обґрунтування заміни вимикачів на РТП та вибір обладнання ... 47 3.4 Розрахунок заземлення на РТП 35/10 кВ ... 52 3.5 Розрахунок блискавкозахисту на РТП ... 54 3.6 Висновки по третьому розділі ... 55 4 Охорона праці та безпека в надзвичайних ситуаціях ... 56 4.1 Аналіз небезпечних факторів та заходи безпеки при обслуговуванні силових трансформаторів ... 56 4.2 Обґрунтування заходів щодо запобігання надзвичайним ситуаціям при експлуатації силових трансформаторів ... 59 ЗАГАЛЬНІ ВИСНОВКИ ... 63 ПЕРЕЛІК ПОСИЛАНЬ ... 65
Довжанин, Олександр Сергійович, та Oleksandr Dovzhanyn. "Розробка системи електропостачання заводу теплоізоляційних матеріалів". Bachelor's thesis, Тернопільський національний технічний університет ім. І. Пулюя, 2021. http://elartu.tntu.edu.ua/handle/lib/35388.
Full textЦілями даної кваліфікаційної роботи бакалавра є: розрахунок навантаження заводу; визначення розрахункового навантаження підприємства в цілому по розрахунковим активним і реактивним навантажень цехів з урахуванням розрахункового навантаження освітлення цехів і території підприємства, втрат потужності в трансформаторах цехових підстанцій, ГПП і лініях. Розрахунок проводиться окремо для високовольтних і низьковольтних навантажень; побудова картограми електричних навантажень з метою визначення найбільш оптимального місця розташування ГПП на території підприємства; розрахунок схеми внутрішньозаводського електропостачання. Для захисту мережі від аварійних режимів провести розрахунок та вибір пристроїв релейного захисту трансформатора та відходящих ліній.
Aims of this qualifying work of bachelor are: calculation of loading of plant; determination of the calculation loading of enterprise on the whole for calculation active and reactive loading of workshops taking into account the calculation loading of illumination of workshops and territory of enterprise, losses of power in the transformers of workshop substations, and lines. A calculation is conducted separately for the high-voltage and low-voltage loading; a construction of the electric loading is with the aim of determining the most optimal location of location of in-plant; calculation of chart of inside factory power supply. For protecting of network from malfunctions to conduct a calculation and choice of devices of relay defence of transformer and lines.
ВСТУП 6 1 АНАЛІТИЧНИЙ РОЗДІЛ 9 1.1 Коротка характеристика об'єкту проектування 9 1.2 Загальні вимоги організації електропостачання промислового підприємства 10 1.3 Висновки до розділу 1. Постановка завдань кваліфікаційної роботи 16 2 РОЗРАХУНКОВИЙ РОЗДІЛ 17 2.1 Визначення розрахункових потужностей об'єктів 17 2.2 Вибір схеми внутрішнього електропостачання 19 2.2.1 Обгрунтування застосовуваної схеми 19 2.2.2 Визначення розрахункових електричних навантажень трансформаторній підстанції 19 2.2.3 Компенсація реактивної потужності 20 2.2.4 Визначення номінальної потужності трансформаторів підстанції 22 2.2.5 Вибір перерізів провідників ліній електропередачі за техніко економічними показниками 25 2.3 Вибір схеми зовнішнього електропостачання 29 2.3.1 Визначення розрахункового навантаження заводу 29 2.3.2 Вибір перерізів провідників ліній електропередачі за техніко економічними показниками 31 2.4 Визначення величини струмів короткого замикання 31 2.5 Висновки до розділу 2 36 3 ПРОЕКТНО-КОНСТРУКТОРСЬКИЙ РОЗДІЛ 37 3.1 Вибір і перевірка електрообладнання за умовами роботи в режимі короткого замикання 373.2 Захист мереж від аварійних режимів 41 3.2.1 Максимальний струмовий захист і струмова відсічка 44 3.2.2 Захист знижувального трансформатора 44 3.3 Швидкодіючий пристрій автоматичного перемикання джерел живлення 49 3.4 Висновки до розділу 3 55 4 БЕЗПЕКА ЖИТТЄДІЯЛЬНОСТІ ТА ОСНОВИ ОХОРОНИ ПРАЦІ 56 4.1 Безпека і охорона праці при ремонті і обслуговуванні електрообладнання 56 4.2 Організаційні заходи захисту персоналу підприємства 59 ЗАГАЛЬНІ ВИСНОВКИ 62 ПЕРЕЛІК ПОСИЛАНЬ 64
Абдалла, Ахмед Алі Мохамед, та Ahmed Ali Mohamed Abdullah. "Забезпечення надійності функціонування розподільчої мережі Борщівського РЕМ". Bachelor's thesis, Тернопільський національний технічний університет імені Івана Пулюя, 2021. http://elartu.tntu.edu.ua/handle/lib/35546.
Full textУ кваліфікаційній роботі виконано характеристику мережі та розрахунок навантажень підстанції 110/10 кВ. Розглянуті варіанти розвитку електричних мереж. Проведено розрахунки проводів повітряних ліній електропередачі та розрахунки та вибір трансформаторів підстанцій 110/10 кВ. Обґрунтовано вибір головної схеми електричних з'єднань.
In qualification work сarried out the characteristic of network and calculation of loads of substation 110/10 kV. Considered versions of electrical networks development. Carried out calculations wires of overhead transmission lines and calculations and selection of transformers of substations 110/10 kV. Substantiated the choice of main circuit of electrical connections.
INTRODUCTION 1 ANALYTICAL SECTION 1.1 Distribution networks 1.2 Classification of electricity consumers according to the reliability of the power supply system 1.3 Redundancy is a way to ensure the reliability of electricity supply 2 CALCULATION AND RESEARCH SECTION 2.1 Network specifications 2.2 Calculation of substation loads 3 PROJECT DESIGNING SECTION 3.1 Designing the electric power network development options 3.2 Selection of substation transformers 3.3 Selection of overhead wires 3.4 Determination of parameters of elements and formation of the electric power network equivalent circuit diagram 3.5 Typical operation modes 3.6 Variants of the main scheme of electrical connections 4 LABOUR OCCUPATIONAL SAFETY AND SECURITY IN EMERGENCY SITUATIONS 4.1 Electric shock Hazards and controls and inadvertent activation of equipmen GENERAL CONCLUSIONS REFERENCES
Безпалько, Богдан Васильович, та B. Bezpalko. "Підвищення ефективності захисту мережі 0,4 кВ при однофазних замиканнях". Thesis, Тернопільський національний технічний університет імені Івана Пулюя, 2014. http://elartu.tntu.edu.ua/handle/123456789/3016.
Full textThe purpose of research is increase of efficiency network protection 0.4 kV through more accurate consideration of zero sequence impedance transformers, relay setpoints selection and optimization of electromechanical devices constructions emergency turning off. Object of research is voltage electric networks of 0.4 kV. The subject of the study is the calculation methods of single-phase short circuits and modes transformers 10/0, 4 kV. Comparison of methods for calculating the single-phase short-circuit is realized and analyzed modes transformers 10/0, 4 kV. A study of the dependence of zero sequence impedance of the transformer with winding connection circuit scheme Y/Yn-0 of its mode of operation taking into consideration the nonlinear properties of magnetic steel and power transformer tank is realized. The operation of the device emergency turning off (RCD) and its electromechanical actuating mechanism are investigated.
Семенчук, Іван Сергійович, та Ivan Semenchuk. "Розробка технічних заходів підвищення пропускної здатності трансформаторної підстанції 110/10 кВ". Master's thesis, Тернопільський національний технічний університет імені Івана Пулюя, кафедра електричної інженерії,Тернопіль, Україна, 2021. http://elartu.tntu.edu.ua/handle/lib/36652.
Full textУ кваліфікаційній роботі магістра здійснено розробку технічних заходів щодо підвищення пропускної здатності трансформаторної підстанції 110/10 кВ. На основі графіків навантаження було вибрано силові трансформатори. Розраховано струми короткого замикання і вибрано комутаційну апаратуру. Розраховано та встановлено нові схеми релейного захисту на основі мікропроцесорного блоку захисту Також передбачається заміна вимірювальних трансформаторів, трансформаторів власних потреб і інші зміни.
In qualifying work of master's degree development of technical measures is carried out in relation to the increase of carrying capacity of transformer substation of 110/10 kV. On the basis of the load-graphs power transformers were chosen. The currents of short circuit are expected and chosen switchgear. The new charts of relay defence are expected and set on the basis of microprocessor block of defence replacement of measuring transformers, transformers of own necessities and other changes are Also foreseen.
ЗМІСТ ВСТУП 6 1 АНАЛІТИЧНИЙ РОЗДІЛ 9 1.1 Модернізація обладнання підстанцій 9 1.2 Підвищення надійності роботи трансформаторної підстанції при заміні основного обладнання 11 1.3 Призначення та основні функції пристрою автоматичного частотного розвантаження Сиріус-2-АЧР 14 1.4 Характеристика споживачів підстанції 14 1.5 Висновки до розділу 1 18 2 РОЗРАХУНКОВО-ДОСЛІДНИЦЬКИЙ РОЗДІЛ 19 2.1 Дані для реконструкції електричній частині підстанції 19 2.2 Розрахунок і побудова добових і річних графіків електричних навантажень підстанції 20 2.2.1 Побудова графіків навантаження сторони 10 кВ 20 2.2.2 Побудова графіків навантаження стороні 110 кВ 24 2.3 Вибір силових трансформаторів на підстанції 26 2.3.1 Вибір потужності трансформаторів 26 2.4 Вибір головної схеми підстанції 28 2.5 Розрахунок струмів короткого замикання. 29 2.6 Висновки до розділу 2 33 3 ПРОЕКТНО-КОНСТРУКТОРСЬКИЙ РОЗДІЛ 34 3.1.Вибір комутаційної апаратури 34 3.1.1 Вибір вимикачів 110 кВ 34 3.1.2 Вибір роз'єднувачів 110 кВ 36 3.1.3 Вибір вимикачів 10 кВ 36 3.2 Вибір ошиновки 38 3.2.1 Вибір ошиновки на стороні високої напруги 38 5 3.2.2 Вибір ошиновки на стороні низької напруги 39 3.3 Вибір опорних і прохідних ізоляторів 10 кВ 41 3.4 Обмежувачів перенапруги (ОПН) 42 3.5 Вибір КРП - 10 кВ 43 3.6 Вибір вимірювальних трансформаторів струму 43 3.6.1 Вибір трансформаторів струму на стороні 110 кВ 43 3.6.2 Вибір трансформаторів струму на стороні 10 кВ 45 3.7 Вибір трансформаторів напруги 47 3.7.1 Вибір трансформаторів напруги на стороні 110 кВ 48 3.7.2 Вибір трансформаторів напруги на стороні 10 кВ 49 3.8 Проектування системи власних потреб підстанції 49 3.8.1 Вибір ТВП 49 3.8.2 Вибір кабелів що живлять щитки ВП від ТВП 51 3.8.3 Вибір кабелів що живлять електроприймачі ТВП 51 3.8.4 Розрахунок струмів короткого замикання системи ВП 51 3.8.5 Вибір запобіжників для ТВП 53 3.8.6 Вибір автоматичних вимикачів на ввідних панелях 54 3.8.7 Вибір автоматичних вимикачів на відходящих електроприймачах ВП 55 3.9 Розрахунок захисного заземлення 56 3.10 Розрахунок грозозахисту 59 3.11 Висновки до розділу 3 60 4 ОХОРОНА ПРАЦІ ТА БЕЗПЕКА В НАДЗВИЧАЙНИХ СИТУАЦІЯХ 61 4.1 Заходи по техніці безпеки при експлуатації електрообладнання 61 4.2 Забезпечення безпечної роботи підстанції 110/10 кВ 63 4.3 Підвищення стійкості роботи об'єкту в умовах можливих надзвичайних ситуацій 65 ЗАГАЛЬНІ ВИСНОВКИ 68 ПЕРЕЛІК ПОСИЛАНЬ 69
Юрійович, Ярченя Максим, та Maksym Yarchenia. "Проект реконструкції трансформаторної підстанції 110/10 кВ". Master's thesis, Тернопільський національний технічний університет імені Івана Пулюя, кафедра електричної інженерії,Тернопіль, Україна, 2021. http://elartu.tntu.edu.ua/handle/lib/36662.
Full textУ кваліфікаційній роботі магістра здійснено розробку проекту реконструкції трансформаторної підстанції 110/10 кВ. В процесі розробки були розглянуті питання, присвячені аналізу прилеглої мережі і споживачів; необхідності модернізації; розрахунок струмів короткого замикання і подальший вибір і перевірка обладнання і струмоведучих частин; релейного захисту і автоматики; захисту підстанції від прямих ударів блискавки; охороні праці. В ході розробки проекту були вибрані сучасні, безпечні і надійні комутаційні апарати, які є актуальними у сфері електроенергетики. Усі рішення приймалися на підставі техніко-економічного порівняння різних варіантів і згідно ПУЕ.
Development of project of reconstruction of transformer substation of 110/10 kV. is carried out in qualifying work of master's degree. In the process of development there were the considered questions sanctified to the analysis of adherent network and consumers; to the necessity of modernisation; calculation of currents of short circuit and further choice and verification of equipment and parts; relay defence and automation; to protecting of substation from the direct shots of lightning; to the labour protection. During development of project modern, safe and reliable interconnect vehicles that are actual in the field of electroenergy were chosen. All decisions were accepted on the basis of comparison of different variants and concordantly PUE..
ЗМІСТ ВСТУП 3 1 АНАЛІТИЧНИЙ РОЗДІЛ 6 1.1 Безпечне функціонування трансформаторних підстанцій 6 1.2 Цифрова підстанція як засіб підвищення надійності електропостачання 13 1.3 Висновки до розділу 1 17 2 РОЗРАХУНКОВО-ДОСЛІДНИЦЬКИЙ РОЗДІЛ 18 2.1 Електричне навантаження споживачів ТП 110/10 кВ 18 2.2 Розрахунок струмів короткого замикання 20 2.2.1 КЗ в точці К1 (110 кВ) 22 2.2.2 КЗ в точці К2 (10 кВ) 23 2.2.3 Результати розрахунків струмів КЗ 25 2.3 Висновки до розділу 2 25 3 ПРОЕКТНО-КОНСТРУКТОРСЬКИЙ РОЗДІЛ 26 3.1 Вибір високовольтного обладнання 26 3.1.1 Вибір вимикача і роз'єднувача 27 3.1.2 Вибір проводу для приєднання трансформаторів до СШ 110 кВ 28 3.1.3 Вибір ЛЕП 110 кВ 30 3.1.4 Вибір комірок КРП - 10 кВ 31 3.1.5 Вибір збірних шин 10 кВ 32 3.1.6 Вибір опорних ізоляторів 34 3.2 Вибір вимірювальних трансформаторів струму і напруги 34 3.2.1 Вибір трансформаторів струму 34 3.2.2 Перевірка трансформаторів струму 35 3.2.3 Вибір трансформаторів напруги 37 3.2.4 Вибір обмежувачів перенапруги 38 3.3 Вибір трансформаторів власних потреб 39 5 3.4 Релейний захист і автоматика 40 3.4.1 Розробка релейного захисту силового трансформатора ТМН 6300/110/10 40 3.4.2 Розрахунок захисту від багатофазних КЗ 41 3.4.3 Розрахунок захисту від зовнішніх КЗ 43 3.4.4 Розрахунок захисту від перевантажень 45 3.4.5 Розробка газового захисту 45 3.4.6 Перевірка трансформаторів струму на 10 % похибку 46 3.4.7 Автоматичне частотне розвантаження 48 3.5 Облік електричної енергії 50 3.6 Висновки до розділу 3 51 4 ОХОРОНА ПРАЦІ ТА БЕЗПЕКА В НАДЗВИЧАЙНИХ СИТУАЦІЯХ 52 4.1 Розрахунок захисного заземлення 52 4.2 Розрахунок захисту підстанції від прямих ударів блискавки 56 4.3 Шляхи і способи підвищення стійкості роботи об'єктів енергетики 59 ЗАГАЛЬНІ ВИСНОВКИ 62 ПЕРЕЛІК ПОСИЛАНЬ 64
Стасін, Сергій Богданович, та Serhii Stasin. "Розробка заходів щодо зниження втрат в електричній мережі трансформаторної підстанції 110/10 кВ". Master's thesis, Тернопільський національний технічний університет імені Івана Пулюя, кафедра електричної інженерії,Тернопіль, Україна, 2020. http://elartu.tntu.edu.ua/handle/lib/33208.
Full textУ кваліфікаційній роботі магістра здійснено розробку заходів зниження втрат в електричній мережі трансформаторної підстанції 110/10 кВ. Здійснений розрахунок електричних навантажень і величин струмів трифазного і однофазного короткого замикання, вибір основного високовольтного обладнання. На підставі отриманих даних про величини струмів короткого замикання проведена перевірка вибраного електрообладнання на термічну і електродинамічну стійкість, а також на комутаційну здатність. Здійснений розрахунок уставок пристроїв захисту та автоматики і вибір системи оперативного струму. Розглядається питання автоматизації підстанції за допомогою SCADA-системи і мікропроцесорних терміналів захисту, автоматики, керування і вимірювання
In the master's qualification work, measures to reduce losses in the electrical network of the 110/10 kV transformer substation were developed. The calculation of electrical loads and currents of three-phase and single-phase short circuit, the choice of the main high-voltage equipment. Based on the obtained data on the values of short-circuit currents, the selected electrical equipment was tested for thermal and electrodynamic stability, as well as for switching capacity. The calculation of the settings of protection devices and automation and the choice of the operating current system. The issue of substation automation with the help of SCADA-system and microprocessor terminals of protection, automation, control and measurement is considered.
ЗМІСТ ВСТУП 5 1 АНАЛІТИЧНИЙ РОЗДІЛ 8 1.1 Аналіз трансформаторної підстанції 8 1.2 Вимоги до підстанції, кліматичні умови 10 1.3 Характеристики виробничих приміщень 11 1.4 Принципова електрична схема підстанції 12 1.5 Режими роботи підстанції і категорії споживачів 15 1.6 Висновки до розділу 1 16 2 РОЗРАХУНКОВО-ДОСЛІДНИЦЬКИЙ РОЗДІЛ 18 2.1 Аналіз електричних навантажень 18 2.2 Оцінка оптимальності місця розташування підстанції 22 2.3 Вибір головної схеми підстанції 28 2.4 Вибір елементів головної схеми підстанції 28 2.5 Розрахунок струмів короткого замикання 31 2.6 Висновки до розділу 2 50 3 ПРОЕКТНО-КОНСТРУКТОРСЬКИЙ РОЗДІЛ 52 3.1 Електричний розрахунок струмопровідних елементів і струмопровідної апаратури 52 3.2 Механічний розрахунок повітряних ліній 55 3.3 Вибір і розрахунок пристроїв РЗА 62 3.6 Висновки до розділу 3 73 4 ОХОРОНА ПРАЦІ ТА БЕЗПЕКА В НАДЗВИЧАЙНИХ СИТУАЦІЯХ 74 4.1 Безпека праці електромонтера по обслуговуванню трансформаторних підстанцій і розподільних пунктів 74 4.2 Принципи і заходи підвищення стійкості функціонування об'єктів економіки 78 ЗАГАЛЬНІ ВИСНОВКИ 81 ПЕРЕЛІК ПОСИЛАНЬ 82
Красножоний, Олег Вікторович, та Oleh Krasnozhonyi. "Розробка технічних заходів щодо забезпечення надійності роботи системи електропостачання олійноекстракційного заводу". Master's thesis, Тернопільський національний технічний університет імені Івана Пулюя, кафедра електричної інженерії,Тернопіль, Україна, 2020. http://elartu.tntu.edu.ua/handle/lib/33422.
Full textУ кваліфкаційній роботі магістра здійснено технічних заходів щодо забезпечення надійності роботи системи електропостачання олійноекстракційного заводу. Виконані розрахунки втрат електроенергії, вибрана найбільш доцільна схема електропостачання, здійснено вибір силових трансформаторів. Для схеми електропостачання підприємства розраховані струми короткого замикання для усіх ступенів напруги за результатами яких була здійснена перевірка усього вибраного обладнання, проводів та кабелів на термічну та електродинамічну стійкість. Вибрані комутаційні апарати – вимикачі та роз'єднувачі. Виконано вибір збірних шин, вимірювальних трансформаторів струму та напруги. Для забезпечення необхідного захист електротехнічного персоналу при аварійних ситуаціях проведений розрахунок контуру заземлення цехових трансформаторних підстанцій.
In the qualification work of the master technical measures were taken to ensure the reliability of the power supply system of the oil extraction plant. The calculations of electricity losses are performed, the most expedient scheme of power supply is chosen, the choice of power transformers is made. For the power supply scheme of the enterprise, short-circuit currents were calculated for all voltage levels, based on the results of which all selected equipment, wires and cables were checked for thermal and electrodynamic stability. Selected switching devices - switches and disconnectors. The choice of busbars, measuring current and voltage transformers is made. To ensure the necessary protection of electrical personnel in emergency situations, the calculation of the grounding circuit of the shop transformer substations.
ЗМІСТ ВСТУП 6 1 АНАЛІТИЧНИЙ РОЗДІЛ 9 1.1 Аспекти забезпечення надійності електропостачання 9 1.2 Проблема схемної надійності на стадії проектування 13 1.3 Розробка принципової схеми управління рівнем надійності електропостачання 17 1.4 Висновки до розділу 1 21 2 РОЗРАХУНКОВО-ДОСЛІДНИЦЬКИЙ РОЗДІЛ 23 2.1 Розрахунок електричних навантажень 24 2.1.1 Розрахунок навантажень по відділеннях 26 2.1.2 Розрахунок освітлювального навантаження по відділеннях 27 2.2 Розрахунок навантажень цеху переробки ріпаку 28 2.3 Вибір числа та потужності трансформаторних цехових підстанцій 29 2.3.1 Компенсація реактивної потужності 32 2.3.2 Розрахунок втрат потужності в трансформаторах 33 2.4 Розрахунок струмів короткого замикання 35 2.4.1 Розрахунок струмів к.з. напругою вище 1000 В 37 2.4.2 Розрахунок струмів к.з. напругою до 1000 В 40 2.5. Висновки до розділу 2 44 3 ПРОЕКТНО-КОНСТРУКТОРСЬКИЙ РОЗДІЛ 45 3.1 Вибір та перевірка високовольтного обладнання та кабельної лінії 45 3.1.1 Вибір та перевірка кабелю по нагріву 45 3.1.2 Вибір та перевірка кабелю по економічній густині струму 46 3.1.3 Вибір вимикачів 48 3.1.4 Вибір роз’єднувачів 51 3.2 Вибір вимірювальних трансформаторів 53 5 3.2.1 Вибір трансформаторів струму 53 3.2.2 Вибір трансформаторів напруги 56 3.3 Вибір збірних шин на напругу 0,4 кВ 57 3.4 Вибір провідникової продукції та комутаційної апаратури 0,4 кВ 60 3.5 Розрахунок та перевірка умов спрацювання захистів до однофазних к.з. в мережах з глухо заземленою нейтраллю 64 3.6 Релейний захист елементів системи електропостачання 66 3.7 Висновки до розділу 3 69 4 ОХОРОНА ПРАЦІ ТА БЕЗПЕКА В НАДЗВИЧАЙНИХ СИТУАЦІЯХ 70 4.1 Безпека і охорона праці при ремонті і обслуговуванні електрообладнання лінії по переробці ріпаку 70 4.2 Розрахунок заземлюючих пристроїв цехових підстанцій 73 ЗАГАЛЬНІ ВИСНОВКИ 76 ПЕРЕЛІК ПОСИЛАНЬ 77
Ніценко, Володимир Вікторович. "Підвищення показників ефективності функціонування релейного захисту збірних шин розподільчих установок". Thesis, Запорізький національний технічний університет, 2018. http://repository.kpi.kharkov.ua/handle/KhPI-Press/34557.
Full textDissertation for a candidate degree (PhD) in Engineering Sciences of the speciality 05.14.02 – Electric power stations, networks and systems. – National technical university "Kharkiv polytechnic institute", Kharkiv, 2018. The dissertation is devoted to the solution of the actual scientific and practical problem in the field of relay protection of electric power systems elements, which is to increase the efficiency of relay busbar protection of switchgears. In this work, the method of phasedifferential busbar protection has been improved, according to which the currents phases comparison algorithm is applied as the sole means of providing absolutely selective protection in emergency conditions, and a group of non-configured parametric settings is introduced that reduces the probability of its non-selective operation through mistakes made by the personnel, as well as due to optimization start and trip conditions of protection operation, its performance increases at internal faults, which allows to refuse the application a high-sensitive protection relay. In order to improve the performance and eliminate the regime limitation of the use of relay protection devices, the method of compensating angular errors of saturated current transformers in the phase-differential busbar protection in the part of ensuring the extension of logic voltage impulses formed from half-waves of distorted currents is improved. The working parameters of the phase-differential busbar protection have been selected, namely the blocking angle is 900 and the impulse formation level is (40-50)%·Іamp, which will ensure its reliable and selective operation in emergency conditions. The mathematical and simulation modeling of the phasedifferential protection behavior and laboratory experiments of its model was carried out, which allowed to confirm the adequacy of the developed model of protection, the efficiency of its algorithms and the correctness of the selected working settings. There were completed analysis of technical and economic indicators of the phase-differential busbar protection using, on the basis of which were determined its advantages compared with the devices of differential busbar protection and approximate estimates of the economic efficiency of its implementation and operation.
Долопікула, Вініта Миколаївна, та Vinita Dolopikula. "Розробка заходів із підвищення надійності електропостачання трансформаторної підстанції 110/10 кВ". Master's thesis, ТНТУ імені Івана Пулюя, 2019. http://elartu.tntu.edu.ua/handle/lib/29757.
Full textThe primary purpose of work are an analysis and development of measures for the increase of reliability of work of transformer substation by modernisation of basic component parts of the system of power supply, that will allow to bring down the losses of electric energy, promote reliability of power supply of consumers. A modern electrical engineering equipment is chosen for all degrees of tension and it is checked for the action of currents of short circuit. Executed short calculation of parameters of the designed air-track of electricity transmission of 110 kV. The tested power transformers are on an emergency and systematic overload on winter day's chart of loading of substation. As devices of relay defence and automation the microprocessor to defence electrical equipments of firm «Бреслер» are applied. Figured on basic parameters of relay defence. Done calculation of loading of own necessities of substation and corresponding transformers are chosen.
ВСТУП 7 1 АНАЛІТИЧНА ЧАСТИНА 10 1.1 Кοрοтка характеристика οб'єкту мοдернізації 10 1.2 Переваги та недοліки викοристання цифрοвих реле 12 1.3 Οбгрунтування дοцільнοсті мοдернізації трансфοрматοрнοї підстанції 15 2 НАУКОВО-ДОСЛІДНА ЧАСТИНА 18 2.1 Οцінка надійнοсті підстанції 18 2.2 Рοзрахунοк пοказників надійнοсті елементів схеми 19 2.2.1. Мοдель відмοв і віднοвлення силοвοгο трансфοрматοра 19 2.2.2 Мοдель відмοв автοматичнοгο вимикача 22 2.2.3. Мοдель відмοв пοвітрянοї лінії електрοпередач 26 2.2.4 Мοдель відмοв і віднοвлення для рοз'єднувачів 29 2.2.5 Мοдель відмοв і віднοвлення для відділювачів і кοрοткοзамикачів 30 2.2.6 Мοдель відмοв і віднοвлення для шин 31 3 ТЕХНОЛОГІЧНА ЧАСТИНА 33 3.1 Обробка графіку навантажень споживачів і перевірка силових трансформаторів по навантаженню підстанції 33 3.2 Вибір головної схеми підстанції 37 3.3 Розрахунок параметрів проектованої ПЛ-110 кВ 37 3.4 Розрахунок струмів короткого замикання 39 4 ПРОЕКТНО-КОНСТРУКТОРСЬКА ЧАСТИНА 50 4.1 Вибір основного електрообладнання і струмоведучих частин 50 4.1.1 Вибір гнучких шин 110 кВ 50 4.1.2 Вибір вимикачів на стороні ВН 52 4.1.3 Вибір роз'єднувачів на стороні ВН 54 4.1.4 Вибір трансформаторів струму на стороні ВН 57 4.1.5 Вибір трансформаторів напруги на стороні ВН 61 4.1.6 Вибір вимикачів на стороні НН 63 4.1.7 Вибір трансформаторів струму на стороні НН 64 4.1.8 Вибір трансформаторів напруги на стороні НН 66 4.1.9 Вибір обмежувачів перенапруги 67 4.2 Вибір релейного захисту і пристроїв автоматики 68 4.2.1 Розрахунок диференціального захисту трансформаторів 68 4.2.2 Розрахунок максимального струмового захисту 71 4.2.3 Захист від перевантаження 72 4.2.4 Газовий захист 73 4.2.5 Автоматичне включення резерву та автоматичне повторне включення 74 4.2.6 Вибір захисту проектованої ПЛ-110 кВ 75 4.3 Власні потреби підстанції 75 5 СПЕЦІАЛЬНА ЧАСТИНА 78 5.1 Розрахунок надійності схеми електропостачання 78 5.1.1 Розрахунок послідовних з'єднань 78 5.2 Облік резервування 84 6 ОБГРУНТУВАННЯ ЕКОНОМІЧНОЇ ЕФЕКТИВНОСТІ 87 6.1 Функціонально-вартісною аналіз проектованого варіанту 87 6.2 Розрахунок окупності і економічна оцінка проекту 97 7 ОХОРОНА ПРАЦІ ТА БЕЗПЕКА В НАДЗВИЧАЙНИХ СИТУАЦІЯХ 101 7.1 Охорона праці і техніка безпеки при обслуговуванні електрообладнання підстанції 101 7.2 Розрахунок грозозахисту підстанції 102 7.3 Забезпечення безпеки життєдіяльності в умовах надзвичайної ситуації 106 8 ЕКОЛОГІЯ 108 8.1 Оцінка стану навколишнього середовища 108 8.2 Небезпека електромагнітного забруднення 109 ЗАГАЛЬНІ ВИСНОВКИ ДО ДИПЛОМНОЇ РОБОТИ 112 ПЕРЕЛІК ПОСИЛАНЬ 113
Ніценко, Володимир Вікторович. "Підвищення показників ефективності функціонування релейного захисту збірних шин розподільчих установок". Thesis, НТУ "ХПІ", 2018. http://repository.kpi.kharkov.ua/handle/KhPI-Press/34554.
Full textDissertation for a candidate degree (PhD) in Engineering Sciences of the speciality 05.14.02 – Electric power stations, networks and systems. – National technical university "Kharkiv polytechnic institute", Kharkiv, 2018. The dissertation is devoted to the solution of the actual scientific and practical problem in the field of relay protection of electric power systems elements, which is to increase the efficiency of relay busbar protection of switchgears. In this work, the method of phasedifferential busbar protection has been improved, according to which the currents phases comparison algorithm is applied as the sole means of providing absolutely selective protection in emergency conditions, and a group of non-configured parametric settings is introduced that reduces the probability of its non-selective operation through mistakes made by the personnel, as well as due to optimization start and trip conditions of protection operation, its performance increases at internal faults, which allows to refuse the application a high-sensitive protection relay. In order to improve the performance and eliminate the regime limitation of the use of relay protection devices, the method of compensating angular errors of saturated current transformers in the phase-differential busbar protection in the part of ensuring the extension of logic voltage impulses formed from half-waves of distorted currents is improved. The working parameters of the phase-differential busbar protection have been selected, namely the blocking angle is 900 and the impulse formation level is (40-50)%·Іamp, which will ensure its reliable and selective operation in emergency conditions. The mathematical and simulation modeling of the phasedifferential protection behavior and laboratory experiments of its model was carried out, which allowed to confirm the adequacy of the developed model of protection, the efficiency of its algorithms and the correctness of the selected working settings. There were completed analysis of technical and economic indicators of the phase-differential busbar protection using, on the basis of which were determined its advantages compared with the devices of differential busbar protection and approximate estimates of the economic efficiency of its implementation and operation.
Герман, Дмітрій Олександрович, та Dmitrii Herman. "Розробка заходів зниження втрат в системі електропостачання ремонтного цеху підприємства". Master's thesis, Тернопільський національний технічний університет імені Івана Пулюя, кафедра електричної інженерії,Тернопіль, Україна, 2020. http://elartu.tntu.edu.ua/handle/lib/33354.
Full textУ кваліфікаційній роботі магістра здійснено розробку заходів зниження втрат в системі електропостачання ремонтного цеху підприємства. Були застосовані сучасні методи, за допомогою яких можна зменшити втрати на дільниці підприємства. Виконано розрахунок електричного навантаження, кількість і потужність силових трансформаторів, розрахована та обрана конденсаторна установка, вибрана комутаційно-захисна апаратура, вибір релейного захисту живлячих елементів, розрахунок контуру захисного заземлення та освітлення.
In the qualification work of the master the development of measures to reduce losses in the power supply system of the repair shop of the enterprise was carried out. Modern methods have been used to reduce losses at the site of the enterprise. The calculation of electrical load, number and power of power transformers, calculated and selected capacitor installation, selected switching and protection equipment, selection of relay protection of supply elements, calculation of protective earthing and lighting circuit are performed.
ЗМІСТ ВСТУП 6 1 АНАЛІТИЧНИЙ РОЗДІЛ 8 1.1 Техніко-технологічний аналіз та характеристика основних видів виробничих процесів 8 1.2 Вимоги, що ставляться до систем електропостачання 10 1.3 Аналіз та вибір величини напруги для живлення струмоприймачів підприємства 12 1.4 Розробка заходів з енергозбереження для об’єкта, що проектується 13 1.5 Висновки до розділу 1 17 2 ПРОЕКТНО-КОНСТРУКТОРСЬКИЙ РОЗДІЛ 18 2.1 Вибір та обґрунтування можливих варіантів технічної реалізації та методів розрахунків 18 2.2 Вибір електричних двигунів для технологічного обладнання 20 2.3 Розрахунок електричного навантаження на дільниці 21 2.4 Компенсація реактивної потужності (застосування ТКРП) 25 2.5 Вибір кількості та потужності силових трансформаторів на підстанції 26 2.6 Вибір та розрахунок високовольтної схеми електропостачання та лінії електропередачі 30 2.7 Висновки до розділу 2 34 3 РОЗРАХУНКОВО-ДОСЛІДНИЦЬКИЙ РОЗДІЛ 35 3.1 Обчислення струмів при короткому замиканні на стороні високої (10 кВ) і низької (0,4 кВ) напруги 35 3.2 Обчислення та перевірка високовольтного обладнання 40 3.3 Обчислення та перевірка вимірювального трансформатору струму та напруги 42 5 3.4 Дослідження кабелю на термічну міцність 43 3.5 Вибір низьковольтної схеми розподілу електроенергії та розрахунок елементів захисту 44 3.6 Релейний захист, автоматика й облік електроенергії 51 3.7 Розрахунок газового захисту 53 3.8 Розрахунок та вибір освітлювальних установок 57 3.9 Висновки до розділу 3 61 4 ОХОРОНА ПРАЦІ ТА БЕЗПЕКА В НАДЗВИЧАЙНИХ СИТУАЦІЯХ 62 4.1 Розрахунок і конструктивне виконання заземлюючих пристроїв 62 4.2 Загальне планування 63 4.3 Безпека на робочому місці 65 4.4 Промисловий пожежний захист 67 4.5 Висновки до розділу 4 69 ЗАГАЛЬНІ ВИСНОВКИ 70 ПЕРЕЛІК ПОСИЛАНЬ 71
Ковальчук, Володимир Іванович, та Volodymyr Kovalchuk. "Забезпечення надійності роботи системи електропостачання підприємства виготовлення будівельних матеріалів". Master's thesis, Тернопільський національний технічний університет імені Івана Пулюя, кафедра електричної інженерії,Тернопіль, Україна, 2020. http://elartu.tntu.edu.ua/handle/lib/33190.
Full textУ кваліфікаційній роботі магістра здійснено розробку заходів для забезпечення надійності роботи системи електропостачання підприємства виготовлення будівельних матеріалів. Виконано модернізацію електропостачання цього підприємства із застосуванням автономних джерел живлення, розрахунок цехових електричних навантажень, розрахунок і вибір внутрішньоцехових мереж, а також живлячих ліній, вибір комутаційно-захисної апаратури, вибір релейного захисту живлячих елементів, розрахунок контуру захисного заземлення та освітлення.
In the qualification work of the master, measures were developed to ensure the reliability of the power supply system of the building materials manufacturer. Modernization of power supply of this enterprise with the use of autonomous power supplies, calculation of shop electrical loads, calculation and selection of in-shop networks, as well as supply lines, selection of switching and protection equipment, selection of relay protection of supply elements, calculation of protective earthing circuit and lighting.
ЗМІСТ ВСТУП 6 1 АНАЛІТИЧНИЙ РОЗДІЛ 9 1.1 Аналіз когенераційних установок 9 1.1.1 Когенераційні газові електростанції 9 1.1.2 Когенерація енергії 9 1.1.3 Когенераційні міні ТЕЦ 10 1.1.4 Газові і дизельні електростанції 11 1.3 Переваги застосування газопоршневої установки Сaterpillar 11 1.4 Досвід адаптації цифрових терміналів РЗА до українських умов 13 1.5 Коротка характеристика об’єкту проектування 13 1.6 Висновки до розділу 1 16 2 РОЗРАХУНКОВО-ДОСЛІДНИЦЬКИЙ РОЗДІЛ 17 2.1 Розрахунок електричних навантажень підприємства 17 2.1.1 Розрахунок цеху, що детально розраховується 17 2.1.2 Розрахунок електричних навантажень по цехах 20 2.1.3 Розрахунок освітлювального навантаження 21 2.1.4 Розрахунок картограми електричних навантажень 22 2.2 Розподіл електроенергії 25 2.2.1 Побудова схеми електропостачання 25 2.2.2 Вибір генераторних установок 26 2.2.3 Вибір трансформатора 27 2.2.4 Вибір перерізу кабелів і шинопроводів 28 2.2.5 Перевірка електричної мережі на втрати напруги 30 2.2.6 Вибір комутаційно-захисних апаратів 32 2.3 Висновки до розділу 2 34 3 ПРОЕКТНО-КОНСТРУКТОРСЬКИЙ РОЗДІЛ 35 3.1 Вибір основного електрообладнання РП 0,4 кВ 35 3.1.1 Вибір вимикачів 35 3.1.2 Вибір жорстких шин 36 3.1.3 Вибір ізоляторів 37 3.1.4 Вибір трансформаторів струму 37 3.2 Розрахунок струмів короткого замикання 39 5 3.2.1 Розрахунок струму короткого замикання кола генератора 39 3.2.2 Розрахунок струму короткого замикання кола трансформатора 44 3.2.3 Перевірка вибраного обладнання по умові КЗ 47 3.3 Розрахунок зовнішнього електропостачання 48 3.3.1 Вибір КЛ 48 3.3.2 Вибір електроустаткування РП 10 кВ. 48 3.4 Розрахунок власних потреб 51 3.5 Вибір релейного захисту і автоматики 52 3.5.1 Розрахунок захисту генераторів 52 3.5.2 Розрахунок захисту трансформатора 54 3.5.3 Розрахунок захисту живлячої кабельної лінії 57 3.5.4 Розрахунок уставок АВР 61 3.6 Розрахунок штучного освітлення 62 3.6.1 Розрахунок внутрішнього освітлення 62 3.6.2 Розрахунок зовнішнього освітлення 64 3.7 Висновки до розділу 3 66 4 ОХОРОНА ПРАЦІ ТА БЕЗПЕКА В НАДЗВИЧАЙНИХ СИТУАЦІЯХ 67 4.1 Забезпечення електробезпеки обслуговуючого персоналу 67 4.2 Розрахунок захисного заземлення 68 4.3 Порядок дії працівників підприємства під час виникнення пожежі 71 ЗАГАЛЬНІ ВИСНОВКИ 74 ПЕРЕЛІК ПОСИЛАНЬ 76
Касяненко, Артем Вікторович. "Врахування потенціалу сонячної електричної станції встановленої на даху багатоквартирного будинку при виборі елементів системи електропостачання". Bachelor's thesis, КПІ ім. Ігоря Сікорського, 2021. https://ela.kpi.ua/handle/123456789/43038.
Full textDuring the implementation of the diploma project, the calculation of the residential area, the network of which reaches more than 1 kV, was performed, and during the calculations, power transformers, automation and protection equipment were selected. In a special issue, a study was conducted on the effectiveness of installing SES on the roof of an apartment building.
Токарчук, Руслан Васильович, та Ruslan Tokarchuk. "Розробка заходів забезпечення безперебійної роботи обладнання трансформаторної підстанції 110/10 кВ". Master's thesis, Тернопільський національний технічний університет імені Івана Пулюя, 2019. http://elartu.tntu.edu.ua/handle/lib/29693.
Full textОсновною метою роботи є розробка, та впровадження заходів для забезпечення безперебійної роботи обладнання трансформаторної підстанції 110/10 кВ, шляхом реконструкції електричної частини підстанції. На основі проведених розрахунків було вибрано оптимальну систему живлення даної підстанції та збільшено її потужність за рахунок заміни існуючих трансформаторів на потужніші. Для гнучкості подальшої модернізації підстанції використані сучасні блокові КТП, а на стороні 10 кВ комірки з вакуумними вимикачами, що встановлюються у ЗРП. Також були розглянуті питання релейного захисту підстанції та відходячих ліній. Крім цього розроблено схему АСКОЕ на базі лічильника «Альфа» та запропоновано запровадити автоматизовану систему розрахунку зі споживачами.
ВСТУП 7 1 АНАЛІТИЧНА ЧАСТИНА 11 1.1 Характеристика електричних навантажень та існуючої мережі 110 кВ в районі розміщення ПС 110/10 кВ 11 1.1.1 Електричні навантаження споживачів ПС 110/10 кВ 11 1.1.2 Існуюча мережа електропостачання споживачів в районі розміщення ПС 110/10 кВ 12 1.2 Переваги та характеристика блокових комплектних трансформаторних підстанцій КТПБ(М) 12 1.3 Загальна характеристика комплектних розподільчих пристроїв К-63 20 2 НАУКОВО-ДОСЛІДНА ЧАСТИНА 26 2.1 Структура втрат електроенергії 26 2.2 Заходи по зниженню втрат електричної енергії в міських електричних мережах 29 3 ТЕХНОЛОГІЧНА ЧАСТИНА 33 3.1 Технічні рішення модернізації ПС 110 кВ і живлячих ПЛ 110 кВ 33 3.1.1 Варіанти схеми зовнішнього електропостачання 33 3.1.2 Вибір силових трансформаторів 33 3.1.3 Вибір схеми підстанції 35 3.1.4 Технічні рішення по будівництву ПЛ 110 кВ 37 3.2 Вибір перерізу проводів 37 3.3 Розрахунок струмів короткого замикання 39 3.3.1 Вибір і складання розрахункової схеми електричної мережі і схеми заміщення 40 3.3.2 Розрахунок параметрів елементів схеми заміщення 42 3.3.3 Визначення струмів при симетричному трифазному КЗ 45 4 ПРОЕКТНО-КОНСТРУКТОРСЬКА ЧАСТИНА 51 4.1 Вибір високовольтного обладнання 51 4.1.1 Вибір трансформаторів власних потреб підстанції 52 4.1.2 Вибір комірок РП–110 і РП–10 53 4.1.3 Вибір вимикачів 54 4.1.4 Вибір роз'єднувачів 56 4.1.5 Вибір обмежувачів перенапруг 56 4.1.6 Вибір шин 57 4.1.7 Вибір ізоляторів 59 4.1.8 Вибір вимірювальних трансформаторів струму 59 4.1.9 Вибір вимірювальних трансформаторів напруги 62 4.2 Розрахунок релейного захист та автоматики 63 4.2.1 Джерела оперативного струму 64 4.2.2 Захист і автоматика трансформаторів 16 МВА 64 4.2.3 Захист і автоматика секційних вимикачів 10 кВ 65 4.2.4 Захист трансформаторів власних потреб і трансформаторів дугогасильних котушок 65 4.2.5 Захист і автоматика ліній 10 кВ 66 4.3 Облік електричної енергії 71 5 СПЕЦІАЛЬНА ЧАСТИНА 73 5.1 Автоматизована система розрахунку з промисловими споживачами 73 5.2 Автоматизована система розрахунку зі споживачами побутового сектора 77 5.3 Нові ефективні системи розрахунків зі споживачами електроенергії 80 6 ОБГРУНТУВАННЯ ЕКОНОМІЧНОЇ ЕФЕКТИВНОСТІ 82 6.1 Техніко-економічне порівняння схем підстанції 110/10 кВ 82 6.2 Визначення показників економічної ефективності капіталовкладень для вибраного варіанту 86 7 ОХОРОНА ПРАЦІ ТА БЕЗПЕКА В НАДЗВИЧАЙНИХ СИТУАЦІЯХ 91 7.1 Охорона праці і техніка безпеки при обслуговуванні електрообладнання підстанції 91 7.2 Розрахунок заземлення 92 7.3 Шляхи і способи підвищення стійкості роботи об'єктів енергетики 95 8 ЕКОЛОГІЯ 97 8.1 Заходи по дотриманні природоохоронних вимог 97 8.2 Джерела електромагнітного забруднення довкілля та їх вплив на навколишнє середовище 98 ЗАГАЛЬНІ ВИСНОВКИ ДО ДИПЛОМНОЇ РОБОТИ 100 ПЕРЕЛІК ПОСИЛАНЬ 101
Nozdrenko, Valerii Stanislavovych, Валерий Станиславович Ноздренков, Валерій Станіславович Ноздренков та Е. А. Шолудько. "Моделирование релейной защиты с помощью среды SPAC 800". Thesis, Изд-во СумДУ, 2008. http://essuir.sumdu.edu.ua/handle/123456789/4125.
Full textКнишук, Вадим Сергійович, та Vadym Knyshuk. "Розробка заходів підвищення надійності електричного обладнання в системі електроспоживання деревообробного підприємства". Master's thesis, ТНТУ імені Івана Пулюя, 2019. http://elartu.tntu.edu.ua/handle/lib/29565.
Full textAn analysis is conducted in diploma work, and development of measures of increase of reliability of electric equipment is carried out in the system of electro-consumption of woodworking enterprise. The calculation of the electric loading is conducted on a plant and on the basis of the obtained data cartogram of the electric loading and graphic arts of the electric loading is built. On results calculations the place of location of main step-down substation was chosen and an amount and power of power transformers are chosen. The chart of inside factory power supply was also chosen and power of workshop transformer substations and distributive points is expected. During implementation of diploma project there were the conducted calculations of reactive-power that is subject to indemnification, there was the conducted choice of switches, disconnectors, transformers of current, transformers of own necessities of substation, terminators of overstrains, facilities of relay defence
ВСТУП 7 1 АНАЛІТИЧНА ЧАСТИНА 11 1.1 Електропостачання промислових підприємств 11 1.2 Особливості розрахунків електропостачальних систем 12 1.3 Вимоги до електричних мереж. Надійність електропостачання 15 1.4 Шляхи підвищення надійності електропостачання 16 1.5 Чинники, що впливають на надійність електрообладнання і систем електропостачання 17 2 НАУКОВО-ДОСЛІДНА ЧАСТИНА 21 2.1 Аналіз чинників, які впливають на надійність роботи електрообладнання 21 2.2 Підвищення надійності електрообладнання промислових підприємств 23 2.2.1 Експлуатація електрообладнання 23 2.2.2 Ремонт електродвигуна 24 2.2.3 Пошук несправностей при експлуатації електрообладнання 25 2.3 Заходи щодо забезпечення надійності роботи електротехнічних пристроїв 26 3 ТЕХНОЛОГІЧНА ЧАСТИНА 31 3.1 Загальна характеристика деревопереробного підприємства 31 3.2 Розрахунок електричних навантажень підприємства 33 3.2.1 Визначення розрахункової потужності технологічного обладнання 34 3.2.2 Визначення розрахункової потужності обладнання котельною 45 3.2.3 Визначення розрахункової потужності освітлювального навантаження 47 3.2.4 Розрахунок сумарного навантаження на КТП 59 4 ПРОЕКТНО-КОНСТРУКТОРСЬКА ЧАСТИНА 51 4.1 Вибір числа і потужності трансформаторів на підстанції 51 4.2 Компенсація реактивної потужності 4.3 Компонування проектованої комплектної трансформаторної підстанції зовнішньої установки 53 4.4 Вибір схеми електропостачання і розрахунок мережі НН 56 4.4.1 Розрахунок перерізів провідників по нагріву і втраті напруги 56 4.4.2 Розрахунок струмів короткого замикання в мережі нижчої напруги і вибір комутаційної апаратури 58 4.5 Розрахунок заземлюючого пристрою 66 4.5.1 Вибір режиму нейтралі 66 4.5.2 Розрахунок заземлюючого пристрою 67 4.6 Розрахунок пристрою грозозахисту 70 4.7 Заходи по підвищенню надійності електропостачання споживачів деревопереробного підприємства 71 4.7.1 Вибір резервного джерела живлення 72 4.7.2 Заміна повітряної лінії електропередачі 10 кВ з використанням захищених проводів і залізобетонних опор 75 5 СПЕЦІАЛЬНА ЧАСТИНА 84 5.1 Автоматичний захист асинхронного двигуна від перевантаження і нагріву 84 5.1.1 Пристрої вбудованого температурного захисту 84 5.1.2 Пристрій ЗОУП-25 89 5.1.3 Універсальний блок захисту асинхронних електродвигунів УБЗ-301 90 6 ОБГРУНТУВАННЯ ЕКОНОМІЧНОЇ ЕФЕКТИВНОСТІ 94 6.1 Визначення капітальних вкладень 94 6.2 Визначення річних експлуатаційних витрат 95 6.3 Складання кошторису електроенергетичних витрат 97 6.4 Розрахунок поточних витрат на обслуговування електрообладнання 101 7 ОХОРОНА ПРАЦІ ТА БЕЗПЕКА В НАДЗВИЧАЙНИХ СИТУАЦІЯХ 104 7.1 Аналіз небезпечних і шкідливих виробничих чинників 104 7.2 Заходи по зниженню негативної дії небезпечних і шкідливих виробничих чинників 107 7.3 Підвищення стійкості функціонування організацій в надзвичайних ситуаціях 110 8 ЕКОЛОГІЯ 112 7.1 Аналіз небезпечних і шкідливих виробничих чинників 112 7.2 Заходи по зниженню негативної дії небезпечних і шкідливих виробничих чинників 113 ЗАГАЛЬНІ ВИСНОВКИ ДО ДИПЛОМНОЇ РОБОТИ 115 ПЕРЕЛІК ПОСИЛАНЬ 117
Хованський, Андрій Васильович, та Andrii Khovanskyi. "Розробка заходів зниження втрат електричної енергії в системі електропостачання підприємства обробки деревини". Master's thesis, ТНТУ імені Івана Пулюя, 2019. http://elartu.tntu.edu.ua/handle/lib/29760.
Full textThe primary purpose of work are an analysis and development of measures of decline of losses of electric energy in the system of power supply of enterprise of treatment of wood. In diploma work the calculation of the electric loading is conducted on a plant and on the basis of the obtained data картограму of the electric loading and graphic arts of the electric loading is built. On results calculations the place of location of ГПП was chosen and an amount and power of power transformers are chosen. The chart of inside factory power supply was also chosen and power of workshop transformer substations and distributive points is expected. During implementation of diploma project there were the conducted calculations of reactive-power that is subject to indemnification, there was the conducted choice of switches, disconnectors, transformers of current, transformers of own necessities of substation, facilities of relay defence.
ВСТУП 7 1 АНАЛІТИЧНА ЧАСТИНА 10 1.1 Втрати електричної енергії в системі електроспоживання 10 1.2 Цехові електричні мережі напругою до 1000 В 11 1.3 Схеми електричних мереж напругою до 1000 В 11 1.4 Конструктивне виконання цехових мереж та підстанцій 12 1.5 Облік електричної енергії 14 1.6 Коротка характеристика підприємства 17 2 НАУКОВО-ДОСЛІДНА ЧАСТИНА 19 2.1 Втрати електричної енергії в системі електроспоживання 19 2.2 Цехові електричні мережі напругою до 1000 В 22 3 ТЕХНОЛОГІЧНА ЧАСТИНА 29 3.1 Розрахунок електричних навантажень 29 3.1.1 Вибір напруги внутрішньозаводського електропостачання 29 3.1.2 Розрахунок освітлювального навантаження 29 3.1.3 Розрахунок силових навантажень 32 3.2 Картограма навантажень і визначення умовного центру електричних навантажень 35 3.3.1 Загальні відомості 35 3.3.2 Визначення центру електричних навантажень 38 3.3 Побудова графіків електричних навантажень 39 4 ПРОЕКТНО-КОНСТРУКТОРСЬКА ЧАСТИНА 44 4.1 Вибір числа і потужності трансформаторів ГПП 44 4.1.1 Основні положення 44 4.1.2 Вибір трансформаторів головної понижувальної підстанції 44 4.2 Вибір схеми внутрішнього електропостачання 48 4.3 Вибір числа і потужності цехових трансформаторів 48 4.3.1 Основні положення 48 4.3.2 Вибір цехових трансформаторів 50 4.4 Компенсація реактивної потужності 51 4.4.1 Вибір потужності конденсаторних батарей в мережі до 1 кВ 51 4.4.2 Вибір потужності конденсаторних батарей в мережі 10 кВ 52 4.5 Розрахунок струмів короткого замикання 53 4.6 Вибір основних елементів схеми електропостачання напругою вище 1 кВ 56 4.6.1 Вибір комутаційного обладнання 56 4.6.2 Вибір шин на головній понижувальній підстанції 59 4.6.4 Вибір трансформатора напруги 61 4.6.5 Вибір кабельних мереж 10 кВ 62 4.6.6 Вибір трансформатора власних потреб 65 4.7 Розрахунок цехової низьковольтної мережі 67 4.7.1 Розрахунок струмів короткого замикання в мережі напругою до 1000 В 67 4.7.2 Вибір обладнання в мережі напругою до 1000 В 71 4.7.3 Розрахунок занулення 73 4.8 Релейний захист і автоматика 74 4.8.1 Релейний захист трансформаторів головної понижувальної підстанції 74 4.8.2 Газовий захист 74 4.8.3 Поздовжній диференціальний струмовий захист 75 4.8.4 Струмова відсічка 78 4.8.5 Захист від багатофазних коротких замикань на стороні низької напруги 79 4.8.6 Резервний захист від міжфазних коротких замикань 80 4.8.7 Захист від перевантажень 81 4.8.8 Захист трансформаторів цехових підстанцій 82 4.8.9 Автоматика 83 5 СПЕЦІАЛЬНА ЧАСТИНА 84 5.1 Автоматичний захист асинхронного двигуна від перевантаження і нагріву 84 5.1.1 Пристрої вбудованого температурного захисту 84 5.1.2 Пристрій ЗОУП-25 87 5.1.3 Універсальний блок захисту асинхронних електродвигунів УБЗ-301 89 6 ОБГРУНТУВАННЯ ЕКОНОМІЧНОЇ ЕФЕКТИВНОСТІ 91 6.1 Визначення капітальних вкладень 91 6.2 Визначення річних експлуатаційних витрат 92 6.3 Складання кошторису електроенергетичних витрат 94 6.4 Розрахунок поточних витрат на обслуговування електроустаткування 99 7 ОХОРОНА ПРАЦІ ТА БЕЗПЕКА В НАДЗВИЧАЙНИХ СИТУАЦІЯХ 102 7.1 Аналіз небезпечних і шкідливих виробничих чинників 102 7.2 Заходи по зниженню негативної дії небезпечних і шкідливих виробничих чинників 105 7.3 Підвищення стійкості функціонування організацій в надзвичайних ситуаціях 108 8 ЕКОЛОГІЯ 110 8.1 Актуалність охорони навколишнього середовища 110 8.2 Заходи по зниженню шумового забруднення довкілля 111 ЗАГАЛЬНІ ВИСНОВКИ ДО ДИПЛОМНОЇ РОБОТИ 113 ПЕРЕЛІК ПОСИЛАНЬ 114
Зінченко, І. М. "Модернізація підстанції 35/10 кВ «М. Дівиця» АТ «Чернігівобленерго»". Thesis, Чернігів, 2021. http://ir.stu.cn.ua/123456789/25276.
Full textОб’єкт дослідження дипломної роботи – двотрансформаторна електрична підстанція 35/10кВ “М. Дівиця”, яка розташована на території Прилуцького району Чернігівської області. Мета даної дипломної роботи – зменшення витрат електроенергії на власні потреби підстанції, реконструкція існуючої схеми електричних з’єднань підстанції, заміна застарілого силового та комутаційного обладнання з метою підвищення надійності роботи електричних мереж Прилуцького РЕМ. У ході виконання дипломної роботи буде обрана схема електричних з’єднань ПС на стороні 35кВ, будуть розраховані параметри аварійних режимів живлення підстанції за результатами яких буде проведено вибір силового і комутаційного обладнання, обрано схему реалізації та розрахунок уставок релейного захисту одного з приєднань 35кВ. Також буде переглянуті існуюча на підстанції система захисного заземлення з урахуванням запропонованої у даному проекті модернізації та чинних нормативних документів, розраховані технікоекономічні показники ефективності запропонованого варіанту реконструкції підстанції.
The object of study of the thesis - two-transformer electrical substation 35 / 10kV "M. Maiden ”, which is located in the Pryluky district of Chernihiv region. The purpose of this thesis is to reduce electricity consumption for the substation's own needs, reconstruction of the existing scheme of electrical connections of the substation, replacement of obsolete power and switching equipment to increase the reliability of electrical networks of Pryluky REM. In the course of the thesis the scheme of electrical connections of the substation on the 35kV side will be selected, the parameters of emergency power supply substations will be calculated. The existing system of protective earthing at the substation will also be reviewed, taking into account the modernization proposed in this project and current regulations, calculated technical and economic performance indicators of the proposed reconstruction of the substation.
Клюєв, Д. В. "Обгрунтування реконструкції ПС 110/б кВ "ЗСО" ДСП "ЧАЕС" в умовах приєднання до неї додаткових генеруючих потужностей". Thesis, Чернігів, 2020. http://ir.stu.cn.ua/123456789/19626.
Full textМетою дипломного проекту є приведення характеристик підстанції "ЗСО" до вимог чинних нормативних документів та забезпечення можливості приєднання СЕС. Основні задачі проекту: виконати якісний аналіз технічного стану підстанції 110/б кВ "ЗСО" щодо можливості приєднання додаткових генеруючих потужностей, обгрунтовано вибрати схеми електричних з'єднань розподільчих утановок, розрахувати струми короткого замикання та вибрати нове електрообладнання для підстанції; вибрати потрібні типи та розрахувати установки релейного захисту силових трансформаторів; розрахувати блискавкозахист та заземлення підстанції; виконати економічне обгрунтування прийнятих рішень
Гундерчук, Володимир Олександрович. "Аналіз та вибір методів компенсації реактивної потужності в мережі електропостачання інструментального цеху електромеханічного заводу". Master's thesis, 2018. http://elartu.tntu.edu.ua/handle/lib/23716.
Full textЗелінський, Ігор Олександрович. "Аналіз та вибір методів компенсації реактивної потужності на ТЗОВ «Дунаєвецький маслозавод»". Master's thesis, 2018. http://elartu.tntu.edu.ua/handle/lib/23805.
Full textТкач, Михайло Віталійович. "Підвищення надійності системи електропостачання ТОВ «Модуль-Україна», м. Кам’янець-Подільський". Master's thesis, 2018. http://elartu.tntu.edu.ua/handle/lib/23806.
Full textЧоп, Андрій Михайлович. "Аналіз та вибір методів компенсації реактивної потужності в мережі електропостачання деревообробного цеху". Master's thesis, 2018. http://elartu.tntu.edu.ua/handle/lib/23808.
Full textКох, Микола Миколайович. "Підвищення надійності системи електропостачання мережі ТП 110/10 кВ". Master's thesis, 2018. http://elartu.tntu.edu.ua/handle/lib/23962.
Full textНазаров, Антон Анатолійович. "Підвищення надійності системи електропостачання мережі ТП 110/35/10 кВ". Master's thesis, 2018. http://elartu.tntu.edu.ua/handle/lib/23963.
Full textФіголь, Олексій Богданович. "Підвищення надійності системи електропостачання мережі ТП 35/10 кВ". Master's thesis, 2018. http://elartu.tntu.edu.ua/handle/lib/23964.
Full textГрицай, Роман Васильович. "Оптимізація режимів роботи електричного обладнання кабельного заводу". Master's thesis, 2018. http://elartu.tntu.edu.ua/handle/lib/23665.
Full textБарило, Володимир Петрович, та Volodymyr Barylo. "Оптимізація системи електропостачання понижувальної підстанції 110/10 кВ для живлення промислових і побутових споживачів". Master's thesis, 2020. http://elartu.tntu.edu.ua/handle/lib/33180.
Full textУ кваліфікаційній роботі магістра проведено оптимізацію системи електропостачання понижувальної підстанції 110/10 кВ для живлення промислових і побутових споживачів. Здійснено вибір силових трансформаторів, високовольтних апаратів, струмоведучих частин та іншого обладнання підстанції; розрахунок освітлення, заземлення і блискавкозахисту підстанції. В результаті виконаних розрахунків прийнята до встановлення типова комплектна трансформаторна підстанція.
In the qualification work of the master the optimization of the power supply system of the 110/10 kV step-down substation for power supply of industrial and household consumers is carried out. The choice of power transformers, high-voltage devices, current-carrying parts and other substation equipment was made; calculation of lighting, grounding and lightning protection of the substation. As a result of the performed calculations, a typical complete transformer substation was accepted for installation.
ЗМІСТ ВСТУП 9 1 АНАЛІТИЧНИЙ РОЗДІЛ 9 1.1 Оптимізація роботи трансформаторів в цілях зниження втрат електроенергії 9 1.2 Модернізація обладнання підстанцій 10 1.3 Аналіз проблеми пошкодження опорно-стержневих ізоляторів 12 1.4 Визначення технічного стану опорно-стержневої ізоляції без відключення від мережі 14 1.5 Висновки до розділу 1 18 2 РОЗРАХУНКОВО-ДОСЛІДНИЦЬКИЙ РОЗДІЛ 19 2.1 Обробка графіків навантажень підстанції 19 2.2 Вибір числа і потужності силових трансформаторів 22 2.3 Вибір головної схеми електричних з'єднань 23 2.4 Розрахунок струмів короткого замикання 25 2.4.1 Розрахунок струмів на стороні 110 кВ проектованої підстанції 26 2.4.2 Розрахунок струмів на шинах 10 кВ проектованій підстанції 27 2.5 Висновки до розділу 2 28 3 ПРОЕКТНО-КОНСТРУКТОРСЬКИЙ РОЗДІЛ 29 3.1 Вибір основного обладнання і струмоведучих частин 29 3.1.1 Вибір високовольтних вимикачів 29 3.1.2 Вибір роз'єднувачів, віддільників і короткозамикачів 31 3.1.3 Вибір обмежувачів перенапруги 32 3.1.4 Вибір запобіжників 32 3.1.5 Вибір заземлювачів нейтралей 32 3.1.6 Вибір струмоведучих частин 33 3.1.7 Вибір ізоляторів 37 3.1.8 Вибір вимірювальних трансформаторів струму і напруги 39 3.2 Вибір релейного захисту і автоматики 42 3.2.1 Диференціальний струмовий захист на реле ДЗТ-11 42 3.2.2 Максимальний струмовий захист з комбінованим пуском напруги від струмів в обмотках трансформаторів, викликаних зовнішніми КЗ 47 3.2.3 Максимальний струмовий захист від струмів в обмотках трансформатора, викликаних перевантаженням 49 3.3 Вимірювання і облік електроенергії 50 3.4 Вибір оперативного струму і джерел живлення 50 3.5 Власні потреби підстанції 51 3.6 Регулювання напруги на проектованій підстанції 52 3.7 Вибір конструкції розподільчих пристроїв, компонування будівель на майданчику підстанції 54 3.8 Висновки до розділу 3 55 4 ОХОРОНА ПРАЦІ ТА БЕЗПЕКА В НАДЗВИЧАЙНИХ СИТУАЦІЯХ 56 4.1 Забезпечення безпечної роботи підстанції 110/10 кВ 56 4.2 Захисне заземлення заземлення підстанції 58 4.3 Підвищення стійкості роботи об’єктів енергетики під час надзвичайних ситуацій техногенного та природного характеру 62 ЗАГАЛЬНІ ВИСНОВКИ 64 ПЕРЕЛІК ПОСИЛАНЬ