Academic literature on the topic 'AFBC Boiler'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'AFBC Boiler.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "AFBC Boiler"

1

Fuller, Jack A., Harvie Beavers, and Robert Bessette. "Atmospheric Fluidized Bed Combustion (AFBC) Plants: An Operations and Maintenance Study." Journal of Energy Resources Technology 128, no. 2 (2006): 150–53. http://dx.doi.org/10.1115/1.2191506.

Full text
Abstract:
The authors analyzed data from a fluidized bed boiler survey distributed during the spring of 2003 to develop appropriate AFBC (Atmospheric Fluidized Bed Combustion) performance benchmarks. The survey was sent to members of CIBO (Council of Industrial Boiler Owners), who sponsored the survey, as well as to other firms who had an operating AFBC boiler on-site. There were three primary purposes for the collection and analysis of the data contained in this fluidized bed boiler survey: (1) To develop AFBC benchmarks on technical, cost, revenue, and environmental issues; (2) to inform AFBC owners a
APA, Harvard, Vancouver, ISO, and other styles
2

Yadav, Amit Kumar, Dr Vivek Kumar Nema, and Dr Gouraw Beohar. "Experimental Analysis of CFBC Boiler and AFBC Boiler with Different GCV, Boiler Loads and Excess Air." International Journal for Research in Applied Science and Engineering Technology 11, no. 5 (2023): 3141–53. http://dx.doi.org/10.22214/ijraset.2023.52280.

Full text
Abstract:
Abstract: The main motive of this study is to experimental analysis of the Atmospheric fluidized bed combustion boiler and Circulating fluidized bed combustion boiler with different gross calorific value of coal, boiler loads and excess air. For this analysis, use textile waste as a primary fuel and calculate GCV with help of bomb calorimeter. Conduct energy calculation of the overall plant and determine the efficiencies and energy losses of all the major components of the thermal power station. The study was carried out at Thermal power station of Industry Yarns at Mandideep and boiler sectio
APA, Harvard, Vancouver, ISO, and other styles
3

Shailesh, Bobade. "Exergy Analysis of Rice Straw Fired Boiler." J. of Advancement in Engineering and Technology 6, no. 3 (2018): 10. https://doi.org/10.5281/zenodo.1290056.

Full text
Abstract:
Exergy analysis is great tool to identify the inefficient energy utilization in a system. Effective energy utilization and its management for minimizing losses has made researchers to look for efficient energy consumption & conversion. Based on several research activity and visit to a rice straw fired power plant, some key observation has made and is presented in this paper The aim of this paper is to be find out amount and source of irreversibility’s generated in boiler of 33 TPH boiler in 8 MW AFBC boiler power plant so that any process in the system that having largest energy dest
APA, Harvard, Vancouver, ISO, and other styles
4

Ramadhan, Fajar, and Fergyanto E. Gunawan. "Optimization of Atmospheric Fluidized Bed Combustion Boiler by Computational Fluid Dynamics." E3S Web of Conferences 426 (2023): 02074. http://dx.doi.org/10.1051/e3sconf/202342602074.

Full text
Abstract:
Viscose rayon is a natural fabric from regenerated cellulose derived from wood pulp, bamboo, or cotton linters. The viscose rayon industry relies on electricity to generate steam for textile production. This study aims to optimize the 45-ton-per-hour Atmospheric Fluidized Bed Combustion (AFBC) boiler. Its efficiency is 78.16%, lower than the industry benchmark of 85.78%. Boiler efficiency decreases as the flue gas temperature increases, reaching 220 degrees Celsius, indicating suboptimal coal fuel utilization for water heating. The study explores two controllable variables: coal calorific valu
APA, Harvard, Vancouver, ISO, and other styles
5

Ashutosh, Kumar*1 &. Raj Kumar2. "PERFORMANCE ANALYSIS OF ATMOSPHERIC FLUIDIZED BED COMBUSTION BOILER." INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY 6, no. 10 (2017): 270–75. https://doi.org/10.5281/zenodo.1012475.

Full text
Abstract:
This paper present an approach for the efficiency improvement of Atmoshpheric Fluidized Bed Combustion Boiler,of Ruchi Soya India Ltd. Durgachak.Haldia.West Bengal.data taken from 3 shift log book of 24 hour average basis.&amp; applying indirect method of heat losses and find that upon decreasing of 31<sup>0</sup>C, efficiency improved by 1<sup>0</sup>C. This paper address the various approach for efficiency improvement of a boiler
APA, Harvard, Vancouver, ISO, and other styles
6

Ravi, K., M. Matheswaran, and S. A. Srinivasan. "Effect of Limestone Addition to Coal on SO2 Emission Control and Erosion-Corrosion Behaviour of Rifle Bore Bed Tube in AFBC Boiler." Solid Fuel Chemistry 58, no. 5 (2024): 408–14. http://dx.doi.org/10.3103/s0361521924700319.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Ravi, K., M. Matheswaran, and S. A. Srinivasan. "Erratum to: Effect of Limestone Addition to Coal on SO2 Emission Control and Erosion-Corrosion Behaviour of Rifle Bore Bed Tube in AFBC Boiler." Solid Fuel Chemistry 59, no. 1 (2025): 76. https://doi.org/10.3103/s036152192501001x.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Berry, E. E., E. J. Anthony, and D. P. Kalmanovitch. "The Uses and Morphology of Atmospheric Fluidized Bed Combustion Wastes From Canada’s First Industrial AFBC Boilers." Journal of Energy Resources Technology 109, no. 3 (1987): 148–54. http://dx.doi.org/10.1115/1.3231340.

Full text
Abstract:
The literature of FBC solid wastes has been critically evaluated and solid wastes from Canada’s first atmospheric fluidized bed combustion (AFBC) boilers at the Canadian Forces Base (CFB) Summerside, Prince Edward Island have been investigated in order to determine possible uses for AFBC wastes. Scanning electron microscopy (SEM), electron microprobe, and chemical and physical tests were employed to determine the suitability of the material for pollution control, construction, and other uses. SEM and ancillary techniques have shown that the chemical and physical properties of the bed material
APA, Harvard, Vancouver, ISO, and other styles
9

Al-Mamari, Ahoud, Abdullah Mohammed Al-Sadi, Majida Mohammed Ali Al-Harrasi, Soundra Pandian Sathish Babu, Issa Hashil Al-Mahmooli, and Rethinasamy Velazhahan. "Biodegradation of aflatoxin B1 by Bacillus subtilis YGT1 isolated from yoghurt." International Food Research Journal 30, no. 1 (2023): 142–50. http://dx.doi.org/10.47836/ifrj.30.1.11.

Full text
Abstract:
Aflatoxin contamination of food products is recognised as a major food safety concern throughout the world because of its carcinogenic, mutagenic, and immunosuppressive effects on human health. Of the various types of aflatoxins, aflatoxin B1 (AFB1) is the ubiquitous and most threatening foodborne mycotoxin to humans. A wide range of detoxification methods is used to reduce the toxic effects of AFB1. In the present work, the ability of probiotics isolated from yoghurt (produced by bacterial fermentation of milk), “laban” (fermented milk beverage), and “idli” batter (fermented rice and black gr
APA, Harvard, Vancouver, ISO, and other styles
10

Goodwin, John L., and Daniel Mahr. "Power Player." Mechanical Engineering 125, no. 07 (2003): 44–46. http://dx.doi.org/10.1115/1.2003-jul-2.

Full text
Abstract:
This article discusses about power station, the Nucla Station, Nucla. This station meant a new fuel source and a major upgrade of the coal handling system, to trim production costs and enable the plant to process more of a lower-grade fuel. Nucla had the modest beginnings in the Rural Electrification Authority program, when Colorado Ute constructed it in 1959. The station had three stoker-fired boilers, each serving a 12-MW steam turbine. The plant provided reliable power to a scenic, but remote area on the western slope of Colorado. A primary advantage of AFBC technology is its ability to use
APA, Harvard, Vancouver, ISO, and other styles
More sources

Book chapters on the topic "AFBC Boiler"

1

Mooi, Jan, and Hans-Joachim Ballach. "Studies on Poplar Clones after Exposure in Open-Top Chambers to Flue Gas from an Atmospheric Fluidised Bed-Boiler (AFBB)." In Mechanisms and Effects of Pollutant-Transfer into Forests. Springer Netherlands, 1989. http://dx.doi.org/10.1007/978-94-009-1023-2_36.

Full text
APA, Harvard, Vancouver, ISO, and other styles

Conference papers on the topic "AFBC Boiler"

1

Vincent, R. Q., V. K. Sethi, and D. R. Wilson. "Component Performance in the 20-MW AFBC Pilot Plant." In CORROSION 1987. NACE International, 1987. https://doi.org/10.5006/c1987-87012.

Full text
Abstract:
Abstract The Tennessee Valley Authority (TVA) has accumulated over 16,000 hours of operating experience at its 20-MW Atmospheric Fluidized Bed Combustion (AFBC) Pilot Plant during the past four years. During this time, extensive efforts have been placed on periodic inspections, failure analysis, corrosion coupon exposures, heat exchanger materials evaluations, and evaluation of erosion of boiler internals. The results of these inspections and analyses are discussed.
APA, Harvard, Vancouver, ISO, and other styles
2

Vincent, R. Q., V. K. Sethi, and E. C. Lewis. "Tube Wastage Performance of FBC Low-Temperature in-Bed Heat Exchangers." In CORROSION 1988. NACE International, 1988. https://doi.org/10.5006/c1988-88142.

Full text
Abstract:
Abstract The Tennessee Valley Authority (TVA) 20-MW Atmospheric Fluidized Bed Combustion (AFBC) Pilot Plant Facility has been the site of a detailed research, development, and demonstration program for the past five years. During this time, careful monitoring of the wastage of boiler internals has been carried out on a frequent basis. Of most importance from the standpoint of maximum wastage has been the in-bed evaporator. Wastage of other 20-MW boiler components has been discussed previously1,2,3 and will not be repeated here. Instead, an attempt will be made to give a detailed history of the
APA, Harvard, Vancouver, ISO, and other styles
3

Bellofatto, Oreste, and Arturo Pessina. "New CCGT Plants for District Heating Using Advanced AFBC Technology." In ASME 1988 International Gas Turbine and Aeroengine Congress and Exposition. American Society of Mechanical Engineers, 1988. http://dx.doi.org/10.1115/88-gt-121.

Full text
Abstract:
This paper considers the utilization of the high temperature Brayton closed cycle with air cooled atmospheric fluidized bed combustor in district heating plants. The main features of a closed cycle plant are compared with those of a conventional steam cycle plant with flue gas desulphurization and with a steam plant fired by a circulating atmospheric fluidized bed boiler. The characteristics of the main items are analyzed.
APA, Harvard, Vancouver, ISO, and other styles

Reports on the topic "AFBC Boiler"

1

Scott, Paul T. PTPLU Dispersion Modeling of the Proposed Waste-Oil Boiler, Hill AFB UT. Defense Technical Information Center, 1990. http://dx.doi.org/10.21236/ada228515.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Berry, E. E., E. J. Anthony, and D. P. Kalmanovitch. The uses and morphology of atmospheric fluidized bed combustion wastes from Canada's first industrial AFBC boilers. Natural Resources Canada/ESS/Scientific and Technical Publishing Services, 1987. http://dx.doi.org/10.4095/302682.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Garrison, James A. Compliance Testing of Grissom AFB Central Heating Plant Coal-Fired Boilers 3 and 5, Grissom AFB, Indiana. Defense Technical Information Center, 1988. http://dx.doi.org/10.21236/ada198185.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Berry, E. E., E. J. Anthony, and D. P. Kalamanovitch. An evaluation of the uses and morphology of atmospheric fluidized bed combustion wastes from CFB Summerside AFBC boilers. Natural Resources Canada/ESS/Scientific and Technical Publishing Services, 1985. http://dx.doi.org/10.4095/302646.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Garrison, James A. Compliance Testing of Hot Water and Steam Boilers, Shaw AFB, South Carolina. Defense Technical Information Center, 1989. http://dx.doi.org/10.21236/ada208701.

Full text
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!