To see the other types of publications on this topic, follow the link: Aguas residuales - Purificación.

Dissertations / Theses on the topic 'Aguas residuales - Purificación'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 48 dissertations / theses for your research on the topic 'Aguas residuales - Purificación.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.

1

Medina, Rosales Zayra Lizeth, and Saenz Jocelyn Miranda. "Remoción de Cu, Zn y Fe en las aguas residuales de la actividad de soldadura y herreria de la localidad de San Francisco Cheje, municipio de Jocotitlán, empleando residuos de Zea mays." Tesis de Licenciatura, Universidad Autónoma del Estado de México, 2015. http://hdl.handle.net/20.500.11799/25497.

Full text
Abstract:
Trata de dar una solución a la contaminación del agua mediante el fenómeno de adsorción empleando biomaterial de Zea mays para la eliminación de iones de cobre, hierrro y zinc asimismo se pretende dar una alternativa diferente para el tratamiento de aguas residuales derivadas de talleres de herrerias y soldaduras en la localidad de San Francisco Cheje perteneciente al municipio de Jocotitlán.
APA, Harvard, Vancouver, ISO, and other styles
2

Arce, Jáuregui Luis Francisco. "Urbanizaciones sostenibles: descentralización del tratamiento de aguas residuales residenciales." Bachelor's thesis, Pontificia Universidad Católica del Perú, 2013. http://tesis.pucp.edu.pe/repositorio/handle/123456789/4568.

Full text
Abstract:
El agua es el recurso natural más valioso de la tierra, sin ella no existiría vida. Alrededor del 71% de la corteza terrestre está cubierta por agua. A pesar de ser tan abundante, solo un reducido porcentaje es utilizable para el consumo humano. Si se quisiera describir el término “consumo humano”, se diría que es el uso del agua para el contacto con los seres humanos. El término es muy amplio ya que al considerar contacto humano se refiere a beber el agua, utilizarla para la limpieza de alimentos, limpieza de materiales, entre otras actividades. El agua es un recurso muy cuidadoso, a pesar de ello se desperdicia este líquido vital en actividades rutinarias con menor importancia y no se cuida que el ciclo regular de ésta llegue a completarse adecuadamente, por lo que cada vez se va reduciendo el volumen de agua potable. Se está viviendo una época crucial donde el correcto y racional uso del agua podría cambiar el curso de la vida de las personas dentro de los próximos años. El Perú es un país que tiene la suerte de contar con agua subterránea que proporciona y llega a satisfacer una considerable cantidad de personas con este vital líquido. Además, el precio del agua es económicamente reducido con respecto a muchos países, ésta puede ser una de las razones por las que no se sabe emplear de manera correcta y consciente el agua. En el Perú no se ha logrado solucionar el tema de la obstrucción del ciclo correcto de utilización del agua, debido a que el agua debe pasar por procesos de tratamiento después de ser empleada, para finalmente destinarla por efluentes adecuados hacia sus orígenes. En algunos lugares se han centrado solo en almacenar aguas residuales domésticas que producen no solo problemas de salud, sino también en el medio ambiente y una falta de control operacional por las entidades prestadoras de agua. En el presente trabajo se dará un alcance de la situación real del Perú en el tema de saneamiento. Se plantearán vías para la reutilización del agua y se buscará mediante una estructura de investigación alternativas de soluciones viables y rentables en el Perú. Las soluciones no solo tendrán como fondo principal el uso racional del agua sino brindar calidad de vida en urbanizaciones sostenibles a las personas.
Tesis
APA, Harvard, Vancouver, ISO, and other styles
3

Gutiérrez, Cuba César. "Depuración fotoquímica- electroquímica de compuestos orgánicos persistentes en agua residual sintética de la industria textil Puente Piedra-Lima." Doctoral thesis, Universidad Nacional Mayor de San Marcos, 2020. https://hdl.handle.net/20.500.12672/15483.

Full text
Abstract:
Realiza un tratamiento de oxidación combinado (Fotoquímico-Electroquímico) a un agua residual sintética de la industria textil con un DQO inicial de 1458 mg/L que contenía una mezcla de tres colorantes reactivos. El diseño experimental de cribado definitivo de tres niveles y la metodología de superficie de respuesta se empleó para entender como los factores influencian a la respuesta (el contenido de DQO en el agua residual tratada) y para optimizar el tratamiento. Factores de cada etapa de tratamiento (etapa Fotoquímica: Relación de reactivos Fenton 11,25-26,25, Tiempo de tratamiento 60-180min, potencia de lámpara 4-18 W, pH 2-4; etapa electroquímica: densidad de corriente: 800-1000 A/m2, pH 7-11, concentración de cloruros 4-6 g/L, temperatura 30-42 ˚C, tiempo de tratamiento 60-180 min, tipo de electrodo Pt-Ti/Ru-Ir), sus interacciones y efectos cuadráticos han sido investigados. Ecuaciones polinomiales de segundo orden fueron utilizados para modelar cada etapa de tratamiento. Se obtuvo coeficientes de determinación ajustados de 0,999 para la etapa fotoquímica y 0,986 para la etapa electroquímica indicando que los modelos son adecuados para propósitos predictivos. Se encontró que la relación de reactivos Fenton con 49,9 % y tiempo de tratamiento con 37,9 % son las contribuciones más significativas para la etapa fotoquímica y la concentración de cloruros con 61,76 % y el efecto de segundo orden de esta variable con 10,16% y la densidad de carga con 8,07 % son las contribuciones más significativas para la etapa electroquímica. Empleando variables de proceso en sus estados óptimos (etapa fotoquímica: relación de reactivos Fenton 18, potencia de lámpara 4 W, pH 2,5, tiempo de tratamiento 180 min; etapa electroquímica: concentración de cloruros 4 g/L, densidad de corriente 800 A/m2, pH 7, tiempo de tratamiento 15 min, electrodo Pt) el método de tratamiento combinado consiguió una reducción de la carga orgánica persistente de 97,7% indicando que es adecuado para el tratamiento de este tipo de aguas residuales.
Tesis
APA, Harvard, Vancouver, ISO, and other styles
4

Fernández, Acuña Sebastián Ignacio. "Tratamiento y disposición de aguas residuales en plantas de tratamientos de agua potable en Chile." Tesis, Universidad de Chile, 2015. http://repositorio.uchile.cl/handle/2250/133319.

Full text
Abstract:
Ingeniero Civil
La falta de normativas específicas que regulen el manejo de las aguas residuales originadas en las plantas de tratamiento de agua potable del país da lugar a prácticas cuestionables como las descargas a cauces naturales. Las descargas de aguas residuales del tratamiento de agua potable no forman parte de la norma de descarga de efluentes líquidos a cuerpos de agua superficiales (D.S. N°90/2000). Esta falta de tratamiento provoca problemas ambientales, como embancamientos en el cauce. La ausencia de un control de las características y parámetros que deben ser reducidos en estas aguas es consecuencia de la falta de normativas que regulen su manejo, lo cual constituye un riesgo para la salud de la comunidad y su entorno. El objetivo es definir los procesos y las unidades que deben componer el tratamiento de las aguas residuales producidas. El propósito del estudio involucra la caracterización de las aguas residuales y la definición de los parámetros relevantes a reducir. Por otra parte se busca recopilar los procesos de tratamiento que se utilizan en Chile para las aguas residuales de las plantas de agua potable y contrastarlo con las situaciones en aquellos países que han regulado el manejo de estas aguas en sus plantas. Para ello se realizó una revisión bibliográfica y recopilación de antecedentes para caracterizar las aguas residuales. Se revisó la base de infraestructura de las plantas de tratamiento de agua potable de Chile para conocer si se provee algún tratamiento a las aguas residuales. Se revisaron normativas y estudios de países en los cuales se ha regulado el tema y los estándares que contemplan. Finalmente se define el tratamiento o el manejo de un agua residual de acuerdo a sus características.
APA, Harvard, Vancouver, ISO, and other styles
5

López, Amésquita Gustavo. "Simulación de una PTAR basado en el modelo de lodos activos N°1 (ASM1) para evaluar la eficiencia de remoción de materia orgánica y nutrientes de las aguas residuales municipales." Bachelor's thesis, Universidad Nacional Mayor de San Marcos, 2021. https://hdl.handle.net/20.500.12672/17942.

Full text
Abstract:
La simulación de una PTAR es una herramienta muy potente, con mucha aplicabilidad y flexibilidad para todo tipo de tratamientos, con la cual se puede simular y analizar diversos escenarios en poco tiempo y a un menor costo. El modelo matemático más empleado para el caso del tratamiento por lodos activos es el ASM1, un modelo muy complejo con trece variables de estado y diecinueve parámetros, reconocido por describir muy bien casi todos los aspectos de los procesos biológicos del sistema. El presente estudio tiene como objetivo aplicar el modelo ASM1 para simular el comportamiento de la PTAR Santa Clara, con la finalidad de evaluar la eficiencia de remoción de la materia orgánica y nitrogenada de las aguas residuales municipales. La metodología se basó en el Protocolo Unificado de las Buenas Prácticas de Modelado (GMP, por sus siglas en inglés), una propuesta desarrollada por la International Wastewater Association (IWA), la cual fue adaptada a cinco pasos: definición del proyecto, recolección y reconciliación de datos, configuración del modelo de planta, calibración del programa y resultados y discusión. Los resultados de la caracterización establecieron que el agua residual del afluente tenía una composición de materia orgánica principalmente particulada (58% de XS, 20% de XI, 17% de SS y 5% de SI), mientras que el material nitrogenado era de tipo amoniacal en su mayoría (64% de SNH, 22% de XND, 13% de SND y 1% de SNO); dichos valores mostraron que la caracterización del afluente fue coherente con los resultados reportados por trabajos similares, lo que permitió implementar satisfactoriamente el modelo altamente complejo del ASM1 en MATLAB®. Asimismo, la simulación del programa calibrado proporcionó concentraciones del efluente de 51.75, 2.55, 3.99, 2.99, 0.22, 68.82 y 7.05 mg/L para el DQO total, DBO5, SST, SSV, N-NH3, N-NO3 y OD, respectivamente. Además, los errores de estas variables, expresados como residuales absolutos, tuvieron valores muy por debajo de lo estipulado por el protocolo GMP, salvo en el caso del DBO5, cuyo error fue de 26.08 mg/L. En tanto que, los porcentajes de remoción fueron de 94.33, 99.47, 98.99, 99.06 y 25.99 % para el DQO total, DBO5, SST, SSV y N total, respectivamente, observando una elevada eficiencia en la remoción de la materia orgánica pero baja para los nitrogenados, causado posiblemente por defectos en el diseño u operación de la planta.
APA, Harvard, Vancouver, ISO, and other styles
6

Anco, Estrella Percy Máximo. "Procedimiento para la separación del cromo hexavalente de efluentes mineros." Bachelor's thesis, Universidad Nacional Mayor de San Marcos, 2004. https://hdl.handle.net/20.500.12672/3028.

Full text
Abstract:
El presente trabajo consiste en el estudio del tratamiento de aguas contaminadas con iones cromo, Cr+6, que son emitidos como efluentes mineros por algunas plantas concentradoras de las Unidades Mineras en nuestro medio, orientadas a la obtención de concentrados sulfurados de Cobre, Plomo y Zinc. En nuestro país, existen plantas concentradoras que aplican técnicas comunes en sus procesos metalúrgicos para la obtención de concentrados de Cobre y Plomo, y se lleva acabo a través de la separación en la flotación selectiva del Cu-Pb. El uso del reactivo dicromato de sodio (Na2Cr2O7) en esta etapa, es el causante de la contaminación de los efluentes mineros con cromo, debido a cambios de pH que se suscitan en el proceso, el cromo se presenta en forma del radical cromato (CrO4-2) en los efluentes finales, contaminando de esta forma el medio ambiente. Es importante el cumplimiento de las normas ambientales vigentes tales como; la Ley General de Aguas (D.S.17552) y la Resolución Ministerial Nº 011-96-EM/VNM (Ministerio de Energía y Minas, Sub-sector de Minería), que establecen los Niveles Máximos Permisibles en los efluentes líquidos para las actividades mineras, la primera contempla el NMP del contaminante cromo, Cr, lo que permitió el desarrollo de este trabajo de investigación para dar solución a este tipo de problema ambiental. El tratamiento de aguas contaminadas por cromo está dado por la reacción química que se presenta con la aplicación de un reactivo reductor sobre la presencia de los radicales cromato (CrO4-2), con previa adición de un modificador de pH al medio ácido, este reactivo permite la reducción del Cr+6 a Cr+3, para luego pasar a una segunda etapa de neutralización, con la adición de un agente neutralizante, sobre el medio obtenido en la primera etapa y de esta forma produciendo el precipitado final que tiene características no tóxicas para el medio ambiente, el proceso se desarrolla en agitación constante. Y finalmente por la separación sólido-líquido con una sedimentación acelerada del precipitado, se obtiene una solución que cumple con los estándares exigidos por las leyes vigentes, menor a 1,0 ppm Cr. (Ley General de Aguas, D.S.17552). El desarrollo de la investigación y las pruebas experimentales se detalla en los capítulos siguientes.
Tesis
APA, Harvard, Vancouver, ISO, and other styles
7

Adrianzén, Flores Miryam Angélica, Sánchez Daniana Catherine Farfán, and Calderón Adela Milagros Gives. "Gestión de la empresa prestadora de servicios de saneamiento Grau S.A. en la implementación de la política de saneamiento relacionada al tratamiento y disposición final de las aguas residuales de la ciudad de Piura y Castilla." Master's thesis, Pontificia Universidad Católica del Perú, 2015. http://tesis.pucp.edu.pe/repositorio/handle/123456789/6353.

Full text
Abstract:
Este trabajo de investigación se orienta desde la Gerencia Social en la gestión que realiza la Empresa Prestadora de Servicio EPS Grau S.A. como responsable de la administración del servicio de saneamiento en las ciudades de Piura y Castilla; en la implementación de la política de saneamiento en el componente tratamiento de las aguas residuales y su disposición final, establecida en el Plan Nacional de Saneamiento 2006 – 2015, que plantea como meta que al año 2015 se debe contar con el 100% de las aguas residuales del ámbito urbano debidamente tratadas. Se identificó como problema “Dificultad de la EPS GRAU S.A para operativizar e implementar la política de saneamiento relacionada al tratamiento y disposición final de las aguas residuales de la ciudad de Piura y Castilla”; la finalidad de nuestra investigación es generar propuestas para mejorar la gestión de la EPS GRAU S.A en el tratamiento de las aguas residuales en la Ciudad de Piura y Castilla y en la disposición final de las mismas. Los resultados del trabajo de campo para las hipótesis o preguntas de investigación nos muestran los siguientes resultados que contribuyen a explicar el problema identificado: En el nivel de coherencia de los lineamientos de la política, entre el Plan Nacional de Saneamiento 2006-2015 y la normatividad relacionada como la Ley de Recursos Hídricos y Ley de Ambiente, existe un desfase; debido a que las metas se plantearon desde el año 2006 y los mecanismos normativos y técnicos recién se han implementado en los últimos años (2009-2010). El proceso de gestión que realiza la EPS Grau S.A. no se encuentra integrado, es decir tiene problemas para cumplir con el proceso técnico requerido para el tratamiento de las aguas residuales, asimismo la concertación e integración de esfuerzos con los demás actores decisores y la sociedad civil, para el cumplimiento del proceso técnico y por ende de la política de saneamiento es escasa. El proceso de concertación para afrontar los problemas de las plantas de tratamiento y disposición final, no ha permitido a la fecha contribuir en soluciones integrales y concretas; a pesar que la nueva normatividad lo exige. El grado de prioridad que se le otorga al tratamiento y disposición final de las aguas residuales es considerado en cuarto nivel; la escasa e inadecuada disponibilidad de recursos (económicos, físicos y humanos); y el trabajo en equipo donde existen condiciones que no se cumplen, como la capacidad de liderazgo, identificación con el objetivo y motivación del personal; forman parte del conjunto de características de la gestión que contribuyen a explicar el problema motivo de nuestra investigación.
Tesis
APA, Harvard, Vancouver, ISO, and other styles
8

Reyes, Araujo Wilyn. "Optimización del tratamiento de aguas residuales domésticas mediante la implementación del sistema MBBR en la provincia Caylloma - AQUAFIL." Master's thesis, Universidad Nacional Mayor de San Marcos, 2020. https://hdl.handle.net/20.500.12672/15532.

Full text
Abstract:
Muestra la optimización del funcionamiento de la planta de tratamiento de aguas residuales de origen domésticas, propiedad de Aquafil. A lo largo de la investigación se desarrolló la evaluación, análisis y optimización del tratamiento de aguas residuales mediante el adicionamiento de Biocarriers a los dos tanques reactores biológicos existentes, lo cual posibilitará que el sistema de lodos activados actual se transforme en un sistema “Moving Bed Biofilm Reactor” -MBBR- y que fundamentalmente consiste en el aumento de la biomasa en los tanques reactores lo cual permite una mayor degradación de la materia orgánica presente, con el cual se llegar a obtener un incremento del 40% de la capacidad total de tratamiento de la planta que es la meta. Culminado el proceso de optimización actualmente se cuenta con una planta capaz de tratar un caudal promedio de 280 m3/d, lo cual cubre los requerimientos de la población asentada en la ciudad de Caylloma y que comprende un total aproximado de 3200 habitantes.
Tesis
APA, Harvard, Vancouver, ISO, and other styles
9

Pérez, Oddershede Astrid Viviana. "Selección de Sistema de Tratamiento de Aguas Residuales para Localidad de Santa Bárbara Usando Metodología de Decisión Multicriterio AHP." Tesis, Universidad de Chile, 2010. http://www.repositorio.uchile.cl/handle/2250/103989.

Full text
Abstract:
El objetivo general de este trabajo de título es proponer un sistema de tratamiento de aguas residuales para la nueva ciudad de Chaitén, la cual será reubicada en la localidad de Santa Bárbara, provincia de Palena, Región de los Lagos. La selección se realizó mediante una metodología de decisión multicriterio conocida como AHP (Proceso Jerárquico Analítico), para lo cual se generó un modelo de selección de alternativas de tratamiento de aguas residuales, que se aplicó a la localidad de Santa Bárbara. Para alcanzar el objetivo planteado, se estudiaron las características de la zona donde se instalará la nueva ciudad, así como también las necesidades y aspectos más importantes de la antigua ciudad de Chaitén. Se analizaron las diferentes alternativas disponibles para el tratamiento de aguas residuales, considerado sus particularidades, aspectos de operación, ventajas y desventajas. Se escogieron seis tecnologías para compararlas entre ellas utilizando el modelo de decisión generado, en donde se consideran los aspectos más importantes que se debe tener en cuenta al momento de instalar una nueva planta de tratamiento de aguas residuales. Los resultados indican que los tratamientos de aguas residuales técnicamente apropiados para el caso de la localidad de Santa Bárbara son: emisarios submarinos, lodos activados con aireación extendida y lombrifiltros. La evaluación de costos de estas alternativas indica que el sistema que presenta menor costo anual equivalente es el de lombrifiltros, dejando en segundo lugar a emisario submarino y por último a aireación extendida. El Proceso Jerárquico Analítico reflejó ser una herramienta útil para estructurar y ordenar el problema de decisión, identificando los aspectos que influyen de manera directa en la selección de alternativas de tratamiento de aguas residuales. Este estudio sirve de base para quienes deben fijar prioridades y tomar decisiones en la selección de alternativas de tratamiento de aguas residuales de cualquier localidad. Como conclusiones finales se puede destacar que la localidad de Santa Bárbara requiere un sistema de tratamiento de aguas residuales que sea sencillo, fácil de operar, de bajos costos de mantención y operación, y de baja generación o tratamiento de lodos, dado a sus propias característicasy al aislamiento de la zona.Los emisarios submarinos resultaron ser una alternativa atractiva de solución, ya que proveen una tecnología eficiente, segura y relativamente económica para la disposición final de aguas residuales.
APA, Harvard, Vancouver, ISO, and other styles
10

Quiroz, Pedraza Pedro Alexis. "Planta de tratamiento de aguas residuales para regadío en la Universidad Nacional Mayor de San Marcos." Bachelor's thesis, Universidad Nacional Mayor de San Marcos, 2009. https://hdl.handle.net/20.500.12672/432.

Full text
Abstract:
Hoy en día es usual hablar de la crisis del agua, hecho que se ha convertido ya en una preocupación mundial. Las reservas aprovechables del vital liquido son cada vez menores y poco se ha hecho para corregir este grabe problema. No se ha logrado hacer conciencia dentro de la sociedad para hacerle frente a esta amenaza, una amenaza que debe ser combatida por todos. Esta situación deberá corregirse pensando siempre en el bienestar colectivo. El presente Informe de Suficiencia, tiene como objetivo principal, diseñar una planta de tratamiento de agua residual(PTAR), para la UNIVERSIDAD NACIONAL MAYOR DE SAN MARCOS (UNMSM), con el fin de reducir sus descargas contaminantes al mar, y a la vez, con el agua tratada regar sus áreas verdes. Además de proporcionar al estudiante y / o profesional interesado en el tema, el conocimiento, pasos y / o metodología para el diseño; Por lo cual se proporciona la información suficiente, para poder llevar acabo el proyecto. Se podrá encontrar y entender convenientemente en este informe, cuales son los estudios básicos necesarios a realizar, para comenzar a diseñar una PTAR. Se establece también los parámetros básicos de diseño; Además conocer las diferentes alternativas de PTAR que se pueden plantear o proponer inicialmente, que luego serán discutidas, evaluadas, y finalmente seleccionar la más adecuada. También contiene, cálculos de dimensionamiento, costos de construcción y operación de la PTAR. Se menciona además el estudio de factibilidad económica del proyecto. Y por ultimo se brinda los requerimientos previos al arranque, operación y mantenimiento del PTAR.
Tesis
APA, Harvard, Vancouver, ISO, and other styles
11

Folch, Sánchez Montserrat. "Tratamiento terciario de aguas residuales por infiltración-percolación: parámetros de control." Doctoral thesis, Universitat de Barcelona, 1998. http://hdl.handle.net/10803/672994.

Full text
Abstract:
En el marco de la demanda creciente de recursos hídricos se establece un equilibrio dinámico entre la oferta, la demanda y la ecología. En el momento en que la demanda supera la oferta y no se cuenta con los recursos naturales suficientes, se tiende al uso de recursos no convencionales, como es el agua residual depurada. Los tratamientos convencionales de depuración no logran disminuir el número de microorganismos patógenos, por lo que el riesgo sanitario sigue siendo considerable. Con el fin de reutilizar esta agua con o sin restricciones sanitarias se tiende al uso de tratamientos terciarios, dentro de este contexto se incluye la infiltración-percolación modificada, definiéndolo como un proceso de depuración aerobio de aguas residuales depuradas o efluentes secundarios a razón de algunos centenares de libros por metro cuadrado y por día, a través de un espesor de arena aportado. El proceso de infiltración-percolación modificado (Ipm), se incluye dentro de los procesos de película microbina, se trata de un filtro secuencial, no sumergido con soportes de biomasa fijo. Se ha trabajado en columnas de PVC en el laboratorio, y con filtros a escala real. Tanto columnas como filtros se regaron con agua procedentes de un efluente secundario de lodos activados, aplicando distintas cargas hidráulicas. Las columnas y los filtros se han mostrado muy efectivos como sistemas de tratamiento terciario, obteniendose a la salida, disminución de 3 a 4 unidades logarítmicas en coliformes fecales y colifagos CN13, y de 2 a 3 unidades logarítmicas en colifagos F+.
APA, Harvard, Vancouver, ISO, and other styles
12

Quiroz, Pedraza Pedro Alexis, and Pedraza Pedro Alexis Quiroz. "Planta de tratamiento de aguas residuales para regadío en la Universidad Nacional Mayor de San Marcos." Bachelor's thesis, Universidad Nacional Mayor de San Marcos, 2009. http://cybertesis.unmsm.edu.pe/handle/cybertesis/432.

Full text
Abstract:
Hoy en día es usual hablar de la crisis del agua, hecho que se ha convertido ya en una preocupación mundial. Las reservas aprovechables del vital liquido son cada vez menores y poco se ha hecho para corregir este grabe problema. No se ha logrado hacer conciencia dentro de la sociedad para hacerle frente a esta amenaza, una amenaza que debe ser combatida por todos. Esta situación deberá corregirse pensando siempre en el bienestar colectivo. El presente Informe de Suficiencia, tiene como objetivo principal, diseñar una planta de tratamiento de agua residual(PTAR), para la UNIVERSIDAD NACIONAL MAYOR DE SAN MARCOS (UNMSM), con el fin de reducir sus descargas contaminantes al mar, y a la vez, con el agua tratada regar sus áreas verdes. Además de proporcionar al estudiante y / o profesional interesado en el tema, el conocimiento, pasos y / o metodología para el diseño; Por lo cual se proporciona la información suficiente, para poder llevar acabo el proyecto. Se podrá encontrar y entender convenientemente en este informe, cuales son los estudios básicos necesarios a realizar, para comenzar a diseñar una PTAR. Se establece también los parámetros básicos de diseño; Además conocer las diferentes alternativas de PTAR que se pueden plantear o proponer inicialmente, que luego serán discutidas, evaluadas, y finalmente seleccionar la más adecuada. También contiene, cálculos de dimensionamiento, costos de construcción y operación de la PTAR. Se menciona además el estudio de factibilidad económica del proyecto. Y por ultimo se brinda los requerimientos previos al arranque, operación y mantenimiento del PTAR.
Tesis
APA, Harvard, Vancouver, ISO, and other styles
13

Bermeo, Garay Martha Mirella, and Garay Martha Mirella Bermeo. "Remoción eficiente de colorante refractario azul MNO reactivo en combinación con vinil sulfónico en aguas residuales mediante técnicas de electrocoagulación y adsorción." Doctoral thesis, Universidad Nacional Mayor de San Marcos, 2017. http://cybertesis.unmsm.edu.pe/handle/cybertesis/6368.

Full text
Abstract:
Estudia la eliminación de color de efluente textil, con grupo reactivo vinil sulfónico que es utilizado en la tintura de algodón y otras fibras celulósicas, el cual es poco biodegradable. Los efluentes están constituidos por impurezas de los textiles, reactivos, compuestos auxiliares y colorantes, presentando las siguientes características: pH 8.93, color 3500 unidades Pt/Co, Demanda Química de Oxígeno (DQO) de 1300 mg/l, Demanda Bioquímica de Oxígeno (DBO) 177 mg/l, turbiedad 137 NTU, entre otros; que interfieren en el paso de la luz solar provocando un desequilibrio en los ecosistemas acuáticos. Existen algunos compuestos refractarios como los colorantes difíciles de eliminar con tratamientos convencionales, por lo que se aplica un la electrocoagulación, emplea electrodos de hierro con diversas configuraciones de celdas y paquetes a diferentes amperajes, voltajes y tiempo de reacción. Los parámetros de respuesta son el porcentaje de remoción de color y la Demanda Química de Oxígeno, con toma de muestras por triplicado, se hicieron pruebas en lote, cuyas variables de operación sirvieron para trabajar en continuo, posteriormente se usó un sistema de adsorción con carbón activado. Se obtuvo 31mg/l de Demanda Química de Oxígeno que equivale a una remoción del 97,54% y 32 unidades de color que equivale al 99,11% de remoción, en el proceso de electrocoagulación y en el de adsorción se consiguió una remoción de 97,95% para Demanda Química de Oxígeno y 99,20% para color, lo que facilita su reutilización o descarga.
Tesis
APA, Harvard, Vancouver, ISO, and other styles
14

Hinostroza, Segura Darryl Helmut. "Proyecto constructivo Planta de Tratamiento de Aguas Residuales Taboada – PTAR Taboada." Bachelor's thesis, Universidad Nacional Mayor de San Marcos, 2013. https://hdl.handle.net/20.500.12672/14297.

Full text
Abstract:
Publicación a texto completo no autorizada por el autor
El documento digital no refiere asesor
Describe del Proyecto Planta de Tratamiento de Aguas Residuales Taboada - PTAR TABOADA, la cual permitirá el tratamiento de las aguas residuales, vertidas por 27 distritos de Lima y Callao a través de los colectores Interceptor Norte, Comas-Chillón y de la Línea de Impulsión Sarita Colonia, antes de su vertimiento final hacia el mar a través de un emisario submarino, cumpliendo con los parámetros de calidad exigidos en la zona costera del cuerpo receptor, según lo establecido en la Ley de Recursos Hídricos(Ley 29338), que regula el uso y gestión integrada de los recursos hídricos.
Trabajo de suficiencia profesional
APA, Harvard, Vancouver, ISO, and other styles
15

Damian, Chafloque Danny Florentino. "Propuesta de un sistema de tratamiento de aguas residuales provenientes del proceso de lavado de filtros de Epsel S. A. Lambayeque para su aprovechamiento." Bachelor's thesis, Universidad Católica Santo Toribio de Mogrovejo, 2019. http://hdl.handle.net/20.500.12423/2006.

Full text
Abstract:
Las estaciones de servicio de saneamiento generan grandes cantidades de aguas residuales producto del lavado de sus filtros que representan pérdidas económicas para las mismas por su vertimiento y sin un tratamiento previo. La planta N° 02 EPSEL Lambayeque, utiliza aproximadamente 420 m3/día de agua para limpieza de sus filtros. Este efluente es desechado al dren Eureka, representando costos por pérdida en venta de agua y posibles multas por contaminación. La presente investigación tiene por objetivo proponer un sistema de tratamiento para reutilizar el agua de lavado y aprovecharla en el consumo humano. Por ello se caracterizó parámetros relevantes de su composición a través de análisis fisicoquímico y microbiológico. Los resultados fueron: pH: 7,80; DBO5: 8,07 mg/l; Aluminio Residual 0,45; Turbidez 525 NTU; Sólidos Sedimentables totales (SST): 4 500 mg/l; Coliformes Termotolerantes: 480 UFC/100 ml y Coliformes fecales: 120 UFC/100 ml, los cuales se encuentran fuera de los estándares de calidad para su potabilización con un tratamiento convencional con excepción del pH. Luego se seleccionó Ultrafiltración como el tratamiento avanzado más idóneo por la composición del agua a partir de factores como costo en tecnología, flujo, consumo de energía y calidad de agua. El sistema cuenta con procesos de sedimentación, coagulación floculación y sedimentación secundaria que permiten obtener agua de calidad, lo que se traduce en aumento en venta de agua potable y evitar costos por sanciones. Finalmente, el análisis costo beneficio, demostró la rentabilidad económica del proyecto indicando que por cada dólar invertido se genera $. 0,101.
Tesis
APA, Harvard, Vancouver, ISO, and other styles
16

Torres, Ríos Wilson Cornelio. "Biorremediación del agua recirculante en el cultivo intensivo del camarón blanco, utilizando microbiota autóctona del ecosistema del mangle rojo." Doctoral thesis, Universidad Nacional Mayor de San Marcos, 2019. https://hdl.handle.net/20.500.12672/10867.

Full text
Abstract:
Determina la actividad biorremediadora de la microbiota autóctona del ecosistema del mangle rojo, utilizada en la biorremediación del agua recirculante en el cultivo del camarón blanco. Los resultados demuestran la eficacia de la microbiota en el proceso de biorremediación al disminuir y mantener en niveles óptimos los parámetros monitoreados en cada una de las fases de producción y evidencian que la biodiversidad microbiana no afecta la salud del crustáceo al mantener similares características metagenómicas. Se concluye que la microbiota del mangle rojo actúa eficazmente en la biorremediación del agua en el cultivo del camarón blanco. Las especies más predominantes son: Unclassified, Uncultured bacterium y Lactobacilos. La técnica empleada evidencia la calidad del agua, salud animal, conservación del medio ambiente y rendimiento del producto.
Tesis
APA, Harvard, Vancouver, ISO, and other styles
17

Ulloa, Ávila Francisco Gabriel. "Diseño del ánodo de una celda de combustible microbiológica para la producción de energía a partir de aguas residuales." Tesis, Universidad de Chile, 2017. http://repositorio.uchile.cl/handle/2250/148985.

Full text
Abstract:
Ingeniero Civil Químico
El tratamiento de aguas residuales es uno de los procesos más importantes que se deben realizar para cuidar el medio ambiente. El principal objetivo de este tratamiento es permitir la disposición de estos efluentes, tanto domésticos como industriales, asegurando que estos no pongan en peligro la salud humana o causen daños inaceptables al medio ambiente. Sin embargo, este proceso tiene un alto costo energético, alcanzando un consumo de entre 560 y 2.300 GWh por año. Es por esto que hoy en día se buscan procesos alternativos para disminuir el gasto energético de estos tratamientos. Una de las alternativas que han surgido son las celdas de combustible microbiológicas, estos dispositivos son celdas electroquímicas que tienen la particularidad de utilizar microorganismos como catalizadores en el proceso de oxidación y/o reducción. El gran potencial de estos sistemas radica en la enorme variedad de microorganismos existentes, ya que, gracias a su metabolismo, abren la posibilidad de degradar diversos compuestos orgánicos presentes en aguas residuales y usarlos como combustibles. Bajo este contexto, el objetivo general de este trabajo de memoria de título fue diseñar, fabricar y caracterizar el ánodo de una celda de combustible microbiológica para la producción de energía a partir de la oxidación de compuestos orgánicos presentes en aguas residuales. Para cumplir con este objetivo, se utilizó el carbono vítreo reticular como material para la construcción de los ánodos utilizados en el estudio. Al calcular el área superficial del material y su conductividad eléctrica, éstas resultaron ser 70 m^2 g^{-1} y 1,11x10^4 Omega^{-1} m^{-1}, respectivamente. Estos valores lo hacen adecuado para su uso como electrodo en sistemas bioelectroquímicos. Con el fin de caracterizar el desempeño electroquímico del ánodo y la electroactividad de éste, se realizaron voltametrías cíclicas e impedancias de espectroscopía electroquímica en dos esquemas experimentales: uno con el anolito inoculado con la bacteria Acidiphilium cryptum y el otro utilizando un electrodo que fue previamente cultivado con el mismo microorganismo. Las voltametrías cíclicas mostraron que en ambos casos, al tener una mayor concentración de bacterias en la celda, la corriente aumentaba. Por otra parte, las impedancias de espectroscopía electroquímica arrojaron que los microorganismos causaron un aumento de la resistencia, tanto en el electrodo, como en la solución de la cámara anódica. Al complementar estos resultados con los de las voltametrías cíclicas, se notó que la actividad catalítica que muestra el microorganismo utilizado tiene un efecto mayor sobre la producción de corriente que el aumento de las resistencias del sistema que causa. En base a los resultados obtenidos a lo largo del estudio, se concluye que la bacteria Acidiphilium cryptum genera un aumento de corriente al ser utilizada en el ánodo de una celda de combustible microbiológica. En vista de lo anterior, se recomienda comenzar con el estudio del cátodo a utilizar, con el fin de realizar una caracterización electroquímica general del sistema.
APA, Harvard, Vancouver, ISO, and other styles
18

Alcarraz, Curi Mario. "Tratamiento de efluentes de dos plantas procesadoras de frutas por bioconversión." Bachelor's thesis, Universidad Nacional Mayor de San Marcos, 2010. https://hdl.handle.net/20.500.12672/224.

Full text
Abstract:
El desarrollo de las industrias alimentarias en el Perú ha mostrado un significativo incremento en los últimos años, tal como lo demuestra los estudios realizados por el ministerio correspondiente; sin embargo el mismo estudio revela que el mayor incremento corresponde al sector informal. Estas industrias no consideran dentro del proceso de producción la gestión de sus efluentes, que poseen alta carga orgánica con un enorme potencial contaminante, porque consideran un “gasto innecesario” que mermaría sus ganancias. Por lo cual el objetivo de la presente investigación fue desarrollar un procedimiento que permita tratar los efluentes de dos plantas procesadoras de frutas, mediante bioconversión a proteínas unicelulares. Las características promedio de los efluentes como la carga orgánica fue calculada por la DBO5 en 4,634.25 mg/L y una turbidez de 171.85 NTU. El tratamiento primario fue realizado por floculación y sedimentación con FeCl3 a la concentración de 50 mg/L. La carga orgánica del sedimento recuperado fue formulado al 15 y 18% de concentración y suplementado a favor del metabolismo de levaduras a un volumen de 10 L en cada caso y sometido a bioconversión en paralelo con una cepa nativa de levadura y una cepa estándar de Saccharomyces cerevisiae, por el método de fermentación Batch en un fermentador de 12 galones de capacidad nominal. Los mejores resultados fueron encontrados en la bioconversión realizada al 15% de materia orgánica con la levadura nativa, habiéndose producido 10.24 g/L de biomasa, la reducción de la DBO5 llegó hasta 125 m/L y la turbidez hasta 5.6 NTU. Valores admitidos como conforme por la Norma Peruana para la eliminación de los efluentes industriales.
The food industries development in Peru have showed significant increased in the last years, such as some research make by relevant ministry; however the same research show the great increase of informal sector, they have effluents with a high organic charge and high pollution potential. These industries don’t consider managing their effluent on the production process because they think that managing it is an unnecessary and don’t let to earn more money. For instant the mean objective of this research was development a procedure to let treating effluents from two fruit processing plant, through bioconversion to unicellular protein. The average characteristics of effluents as the organic charge was measured by DBO (oxygen biochemical demand) on 4634,25 mg/L and turbidity of 171.85 NTU. The primary treatment was carried out by flocculation and sedimentation with FeCl3 at 50 ppm. The organic charge from recovered sediment was made at 15 and 18% of concentration and supplemented to improve the yeast metabolism in a volume of 10L for each case and subject at bioconversion at the same time with yeast native strain and Saccharomyces cerevisiae strain by batch fermentation method in 12 gallons of fermented. The best result were found on 15% of organic material with yeast native, that produced 10,24g/L of biomass, the DBO reduction came up 125mg/L and the turbidity up 5,6 NTU. These values are according with Peruvian standard to industrial effluent.
Tesis
APA, Harvard, Vancouver, ISO, and other styles
19

Flores, Solano Carlos Alonso. "Aplicación de un ANOVA bifactorial y modelamiento en el tratamiento por floculación de aguas residuales del camal municipal de Andahuaylas." Bachelor's thesis, Universidad Nacional Mayor de San Marcos, 2014. https://hdl.handle.net/20.500.12672/13925.

Full text
Abstract:
La presente Tesina tiene como objetivo aplicar un ANOVA bifactorial y modelos matemáticos en el proceso de floculación con mucílago de penca de tuna (nopal) y el almidón de papa de las aguas residuales de las aguas residuales del camal Municipal de la cuidad de Andahuaylas. Para evaluar la capacidad floculante del mucílago de penca de tuna (nopal) y el almidón de papa de las aguas residuales del camal Municipal de la cuidad de Andahuaylas se realizara el análisis estadístico de las variables de respuesta como el porcentaje de floculación y transmitancia del agua tratada, esto nos permitirá verificar la existencia de diferencias significativas entre medias de los tratamientos y el efecto en las variables de respuesta. La determinación de los valores adecuados u óptimos de las variables de entrada o independientes en el proceso de floculación, se realizará a través de modelos matemáticos a fin de conocer el efecto de las variables sobre la respuesta, así mismo los modelos matemáticos se probaran utilizando estadígrafos de ajuste, el ajuste de los modelos será desarrollado a través del método de estimación de los mínimos cuadrados, entre los valores experimentales y los valores reportados por el modelo matemático, mientras que la calidad de ajuste de los modelos, se evaluará a través del error medio absoluto.
Trabajo de suficiencia profesional
APA, Harvard, Vancouver, ISO, and other styles
20

Alcarraz, Curi Mario, and Curi Mario Alcarraz. "Tratamiento de efluentes de dos plantas procesadoras de frutas por bioconversión." Bachelor's thesis, Universidad Nacional Mayor de San Marcos, 2010. http://cybertesis.unmsm.edu.pe/handle/cybertesis/224.

Full text
Abstract:
El desarrollo de las industrias alimentarias en el Perú ha mostrado un significativo incremento en los últimos años, tal como lo demuestra los estudios realizados por el ministerio correspondiente; sin embargo el mismo estudio revela que el mayor incremento corresponde al sector informal. Estas industrias no consideran dentro del proceso de producción la gestión de sus efluentes, que poseen alta carga orgánica con un enorme potencial contaminante, porque consideran un “gasto innecesario” que mermaría sus ganancias. Por lo cual el objetivo de la presente investigación fue desarrollar un procedimiento que permita tratar los efluentes de dos plantas procesadoras de frutas, mediante bioconversión a proteínas unicelulares. Las características promedio de los efluentes como la carga orgánica fue calculada por la DBO5 en 4,634.25 mg/L y una turbidez de 171.85 NTU. El tratamiento primario fue realizado por floculación y sedimentación con FeCl3 a la concentración de 50 mg/L. La carga orgánica del sedimento recuperado fue formulado al 15 y 18% de concentración y suplementado a favor del metabolismo de levaduras a un volumen de 10 L en cada caso y sometido a bioconversión en paralelo con una cepa nativa de levadura y una cepa estándar de Saccharomyces cerevisiae, por el método de fermentación Batch en un fermentador de 12 galones de capacidad nominal. Los mejores resultados fueron encontrados en la bioconversión realizada al 15% de materia orgánica con la levadura nativa, habiéndose producido 10.24 g/L de biomasa, la reducción de la DBO5 llegó hasta 125 m/L y la turbidez hasta 5.6 NTU. Valores admitidos como conforme por la Norma Peruana para la eliminación de los efluentes industriales.
The food industries development in Peru have showed significant increased in the last years, such as some research make by relevant ministry; however the same research show the great increase of informal sector, they have effluents with a high organic charge and high pollution potential. These industries don’t consider managing their effluent on the production process because they think that managing it is an unnecessary and don’t let to earn more money. For instant the mean objective of this research was development a procedure to let treating effluents from two fruit processing plant, through bioconversion to unicellular protein. The average characteristics of effluents as the organic charge was measured by DBO (oxygen biochemical demand) on 4634,25 mg/L and turbidity of 171.85 NTU. The primary treatment was carried out by flocculation and sedimentation with FeCl3 at 50 ppm. The organic charge from recovered sediment was made at 15 and 18% of concentration and supplemented to improve the yeast metabolism in a volume of 10L for each case and subject at bioconversion at the same time with yeast native strain and Saccharomyces cerevisiae strain by batch fermentation method in 12 gallons of fermented. The best result were found on 15% of organic material with yeast native, that produced 10,24g/L of biomass, the DBO reduction came up 125mg/L and the turbidity up 5,6 NTU. These values are according with Peruvian standard to industrial effluent.
Tesis
APA, Harvard, Vancouver, ISO, and other styles
21

Cuba, Tello María Vanessa. "Tratamiento de agua residual procedente de lavadoras por el método de electrocoagulación para la reutilización en riego de vegetales - Ate Vitarte." Master's thesis, Universidad Nacional Mayor de San Marcos, 2020. https://hdl.handle.net/20.500.12672/11734.

Full text
Abstract:
La electrocoagulación (EC) está llamando la creciente atención para la eliminación de diferentes contaminantes presentes en los diversos efluentes, en estos últimos años. Por medio de este trabajo, se comprobó la viabilidad de usar la técnica de electrocoagulación como una opción ante los procesos químicos convencionales en el tratamiento del agua residual originario de lavadoras para ser reutilizado en riego de vegetales. Cuatro factores se analizaron: la intensidad, tiempo, distancia y pH; con tres niveles para cada factor. Para mejorar el proceso de electrocoagulación sobre los factores de diseño, se diseñaron los experimentos de acuerdo al método de Taguchi. Se realizó el análisis de varianza (ANOVA) para ver el efecto de los variables sobre la remoción de la turbiedad y otros parámetros fisicoquímicos. Los resultados de los parámetros de mayor influencia en la remoción de la turbiedad fueron el tiempo y la intensidad a diferencia de los demás. La optimización de los factores sobre la alta remoción de los parámetros fisicoquímicos se adquirió a los niveles de intensidad 5 Amperios, tiempo de 15 minutos, distancia de 2 centímetros y a pH 7.5, con una remoción de 99.02% en turbiedad, 90.83% en demanda química de oxígeno y 95.93% en sólidos suspendidos totales, por lo cual el efluente tratado está por debajo del valor de la normativa del D.S. N° 004-2017-MINAM para la categoría 3: Riego de vegetales y bebida de animales (Estándares de Calidad Ambiental) y el D.S.N°021-2009 VIVIENDA (Valores Máximos Admisibles) para su uso en riego de vegetales.
Tesis
APA, Harvard, Vancouver, ISO, and other styles
22

López, Serna Rebeca. "Análisis y destino de residuos farmacéuticos en aguas subterráneas, superficiales y residuales." Doctoral thesis, Universitat de Barcelona, 2013. http://hdl.handle.net/10803/128799.

Full text
Abstract:
Los fármacos, compuestos químicos con actividad biológica, y sus productos de transformación, metabolitos y otros derivados en las plantas de tratamiento y en el medio ambiente, con actividad farmacológica remanente, son contaminantes antropogénicos que, en muchos casos, están llegando al medioambiente a través de las aguas residuales, y son las aguas superficiales el primer y principal compartimento ambiental destino. Este es un hecho que, en la actualidad, es ya ampliamente reconocido por la comunidad científica, tras el desarrollo de métodos de análisis capaces de la determinación de estos microcontaminantes en el medio ambiente, y su posterior aplicación en estudios de presencia en diferentes matrices ambientales. Los científicos, por lo tanto, están demandando medidas de control de los mismos por parte de las autoridades. Aunque tímidos, se están dando pasos adelante en materia legislativa en la lucha contra este tipo de contaminación, lo que muestra la toma de conciencia de la importancia en el control de las fuentes de entrada de estos contaminantes emergentes, así como de su eliminación del medioambiente. Esto conlleva un aumento importante en el número de estudios y, por lo tanto, en las muestras a procesar por parte de los laboratorios medioambientales. De ahí nace la necesidad de optimizar la eficiencia y competitividad de los métodos analíticos actuales, de manera que progresen en fiabilidad y sensibilidad, aumentando al mismo tiempo su versatilidad, así como su capacidad y rendimiento. El desarrollo tecnológico en el sector es muy rápido, y en general, es la comunidad científica la que evalúa en primer término la viabilidad y bonanza de las diferentes propuestas tecnológicas. Con la presente tesis se ha pretendido dar respuesta a estas necesidades. Así se ha llevado a cabo: - El desarrollo y validación de métodos analíticos para la determinación de fármacos y sus derivados en aguas medioambientales y residuales, mostrando las ventajas y puntos débiles de cada uno de ellos. En concreto, se han usado dos fuentes de fiabilidad, que no son excluyentes y pueden ser utilizadas simultáneamente. La primera ha consistido en la introducción de la automatización en el tratamiento de muestra, llevando al mínimo la manipulación de las muestras por parte del analista. La segunda ha consistido en la introducción de surrogados y patrones internos adecuados que han puesto de manifiesto las incidencias producidas durante el proceso analítico, para que hayan podido ser corregidas. Por otro lado, se han conseguido métodos que presentan una elevada sensibilidad para la determinación de los microcontaminantes objeto de estudio presentes a bajas concentraciones en matrices complejas. Para ello se ha utilizado espectrómetros de masas de triple cuadrupolo de última generación, que trabajando en modo SRM (Selected Reaction Monitoring), han proporcionado una muy buena sensibilidad, además de una elevada selectividad, que ha allananado el camino de la fiabilidad comentada anteriormente. Además, se apostó también, por el desarrollo de métodos con la suficiente versatilidad como para que hayan podido ser aplicados sobre cualquier tipo de agua ambiental dulce continental, tanto superficial como subterránea, así como a agua residual y potable, con el fin de propiciar la intercalación de muestras de diferente naturaleza analizadas consecutivamente en una misma tanda. Finalmente, se propusieron métodos dotados de una elevada capacidad, de manera que un solo método haya sido capaz de analizar el mayor número de residuos de interés posibles, incluyendo fármacos y sus derivados, metabolitos y otros productos de transformación. Pero a la vez, se ha conseguido un aumento en el rendimiento analítico de estos métodos, es decir, se ha logrado una disminución del tiempo de análisis por muestra y un aumento del número de muestras por día. Para esto se apostó claramente por la automatización, eliminando algunas etapas en el proceso analítico, lo que, además de redundar en fiabilidad como se ha comentado anteriormente, ha proporcionado métodos analíticos más cortos y autónomos y, por lo tanto, capaces de trabajar en ausencia del analista. Otra enfoque en esta dirección fue la utilización de cromatografía rápida. - Otra parte importante de la presente tesis, ha sido la aplicación posterior de los métodos desarrollados, en estudios medioambientales de elevado interés científico por su innovación. En concreto en los siguientes: A) Estudio del impacto medioambiental a escala real, en un escenario de reutilización de agua residual para el mantenimiento del caudal ecológico de un río mediterráneo. Además, se valoró el riesgo ecotoxicológico y de estrogenicidad en las muestras del río. B) Estudio de presencia de fármacos y sus productos de transformación en las aguas superficiales de la cuenca del río Ebro. C) Estudio de la distribución tridimensional y origen de residuos farmacéuticos (fármacos y sus productos de transformación) en las aguas subterráneas bajo la ciudad de Barcelona (España). D) Determinación enantiomérica de 13 residuos farmacéuticos quirales en las aguas superficiales de la cuenca del río Guadalquivir, así como en las aguas de entrada y salida a las principales EDARs asociadas a la cuenca. Además, se discutieron las implicaciones en la toxicidad de las relaciones racémicas y no racémicas.
Pharmaceuticals are compounds with biological activity and their transformation products with remaining activity are arriving the environment through sewage waters, and superficial waters are the main receiving compartment. Some steps towards the fight this kind of contamination. This is creating an increase in the number of studies, and therefore, in the number of samples to be processed by the environmental laboratories. For this reason, the need to optimize the efficiency of current analytical methods, by improving the reliability, sensitivity, versatility, capacity and throughput, is a must. Technologic development is very fast in the sector, and the scientific community is generally the one that first assesses it. This thesis has tried to give answer to these requests. Thus, four multi-residue analytical methods for the analysis of pharmaceuticals and their transformation products in environmental and sewage waters, have been developed making use of cutting edge technology. The advantages and disadvantages of each of them have been discussed. Different online and offline pre-treatment technologies, fast and conventional liquid chromatographies and several kinds of triple quadrupoles for mass spectrometry, have been tested. Other important part of this thesis has been the application of the developed methods with high scientific studies, as follows: - Impact of the discharge of reclaimed sewage water in a Mediterranean river, and assessment of the eco-toxicological consequences. - Presence of pharmaceuticals and their transformation products in Ebro River basin, one of the main ones in the Iberian Peninsula. - Three-dimensional distribution of pharmaceuticals and their transformation products in the ground waters underlying Barcelona city (Spain). - Enantimeric determination of 13 chiral pharmaceutical residues in Guadalquivir River basin, one of the main ones in the Iberian Peninsula, and the assessment of the eco-toxicity issues related.
APA, Harvard, Vancouver, ISO, and other styles
23

Curo, Zevallos Carlos Enrique. "Planteamiento general del sistema de suministro de aguas servidas para el riego de áreas verdes en la Universidad Nacional Mayor de San Marcos." Bachelor's thesis, Universidad Nacional Mayor de San Marcos, 2016. https://hdl.handle.net/20.500.12672/8280.

Full text
Abstract:
Publicación a texto completo no autorizada por el autor
El documento digital no refiere asesor
Revisa y compara los diferentes sistemas de plantas de aguas residuales teniendo en cuenta la necesidad y la inversión económica para desarrollar un proyecto de investigación sobre tratamiento de aguas negras, para reutilizar el agua que se consume en la Universidad Nacional Mayor de San Marcos. La universidad junto con la comunidad universitaria, deben trabajar mancomunadamente en programas de generación de desechos, recolección de basuras, tratamiento de aguas residuales de cualquier origen con sistemas de tratamiento de agua residual de excelencia. La problemática que se presenta es el gasto indiscriminado de agua potable para el riego de áreas verdes en toda la universidad. El principal beneficio que proporciona las plantas de tratamiento es la recuperación del agua residual para su reutilización en procesos que no requieren la calidad de agua destinada para consumo humano (p. ej. riego de jardines).
Trabajo de suficiencia profesional
APA, Harvard, Vancouver, ISO, and other styles
24

Bermeo, Garay Martha Mirella. "Remoción eficiente de colorante refractario azul MNO reactivo en combinación con vinil sulfónico en aguas residuales mediante técnicas de electrocoagulación y adsorción." Doctoral thesis, Universidad Nacional Mayor de San Marcos, 2017. https://hdl.handle.net/20.500.12672/6368.

Full text
Abstract:
Estudia la eliminación de color de efluente textil, con grupo reactivo vinil sulfónico que es utilizado en la tintura de algodón y otras fibras celulósicas, el cual es poco biodegradable. Los efluentes están constituidos por impurezas de los textiles, reactivos, compuestos auxiliares y colorantes, presentando las siguientes características: pH 8.93, color 3500 unidades Pt/Co, Demanda Química de Oxígeno (DQO) de 1300 mg/l, Demanda Bioquímica de Oxígeno (DBO) 177 mg/l, turbiedad 137 NTU, entre otros; que interfieren en el paso de la luz solar provocando un desequilibrio en los ecosistemas acuáticos. Existen algunos compuestos refractarios como los colorantes difíciles de eliminar con tratamientos convencionales, por lo que se aplica un la electrocoagulación, emplea electrodos de hierro con diversas configuraciones de celdas y paquetes a diferentes amperajes, voltajes y tiempo de reacción. Los parámetros de respuesta son el porcentaje de remoción de color y la Demanda Química de Oxígeno, con toma de muestras por triplicado, se hicieron pruebas en lote, cuyas variables de operación sirvieron para trabajar en continuo, posteriormente se usó un sistema de adsorción con carbón activado. Se obtuvo 31mg/l de Demanda Química de Oxígeno que equivale a una remoción del 97,54% y 32 unidades de color que equivale al 99,11% de remoción, en el proceso de electrocoagulación y en el de adsorción se consiguió una remoción de 97,95% para Demanda Química de Oxígeno y 99,20% para color, lo que facilita su reutilización o descarga.
Tesis
APA, Harvard, Vancouver, ISO, and other styles
25

Mena, Ayala Alejandro. "Tratamiento de aguas residuales industriales, mediante el sistema de pasivos artificiales (wetland), en la mina San Genaro." Master's thesis, Universidad Nacional Mayor de San Marcos, 2017. https://hdl.handle.net/20.500.12672/7662.

Full text
Abstract:
Publicación a texto completo no autorizada por el autor
Determina en qué medida la aplicación del tratamiento de aguas residuales industriales mediante el sistema de pasivos artificiales (wetland), y su posterior recirculación, disminuirá significativamente el nivel de contaminación ambiental generado por las aguas acidas y metales pesados en la mina San Genaro y la comunidad campesina de Santa Ana, ubicadas en Huancavelica, Perú. Determina en qué medida la aplicación del tratamiento de aguas residuales industriales mediante pozas de decantación y sistema tipo wetland y su posterior recirculación, disminuirá significativamente el nivel de contaminación ambiental, generado por metales pesados y otros componentes, de modo que cumplan con los parámetros ambientales establecidos por las leyes peruanas. Determina si la aplicación del tratamiento de aguas residuales industriales mediante pozas de oxidación y sistema tipo wetland, y su posterior recirculación será mucho más económico que un sistema de tratamiento tradicional.
Tesis
APA, Harvard, Vancouver, ISO, and other styles
26

Silva, Rodriguez Walter Edwin. "Ampliación de la planta de tratamiento de aguas servidas totora de la ciudad de Ayacucho." Bachelor's thesis, Universidad Nacional Mayor de San Marcos, 2008. https://hdl.handle.net/20.500.12672/14210.

Full text
Abstract:
Realiza un análisis técnico del funcionamiento depurativo de la actual planta de tratamiento, la misma que recientemente ha sido rehabilitada por la entidad prestadora de saneamiento (EPSASA) de Ayacucho. Como resultado de un incremento acelerado en la población de la ciudad de Ayacucho, el diseño proyectado con un primer horizonte al año 2014, se evidencia y advierte una mayor carga orgánica al previsto para este año, por lo que se hace necesario ampliar las unidades depurativas en el presente periodo. Dentro de los parámetros de partida, se demuestra que, a cinco años de su funcionamiento dicha planta ha excedido su capacidad en cuanto al tratamiento de la carga orgánica, en su capacidad hidráulico está funcionando por debajo de lo previsto para el 2020. Dado el emplazamiento actual de la planta de tratamiento, esta nos limita a decidir entre adicionar un tanque IMHOFF o un filtro percolador, de los datos experimentales obtenidos se ha concluido que es el filtro percolador quien posee mejor capacidad para remover mayor porcentaje de carga orgánica (80%), por lo que se plantea la ampliación de esta estructura. Se presenta el diseño tentativo para que EPSASA pueda tomarla en consideración e implementarla a la actual planta de tratamiento de aguas servidas. Así mismo se ha desarrollado las consideraciones conceptuales y la metodología a seguir para el diseño de un filtro percolador. Dentro del desarrollo del presente trabajo se recomienda implementar un sistema de monitoreo permanente para lo cual se ha elaborado un plan de monitoreo según el grafico y los parámetros que se muestran en el capítulo correspondiente. Finalmente, el presente trabajo monográfico es el resultado de un análisis in situ de problemas que afectan directamente a la salud de la población huamanguina y que corresponde a la EPSASA, corregir estas anomalías presentadas en la actualidad.
Trabajo de suficiencia profesional
APA, Harvard, Vancouver, ISO, and other styles
27

García, Alzamora Moisés Manolo. "Diseño planta de tratamiento de aguas residuales Lagunas Facultativas C.P.M. El Porvenir Supe provincia – Barranca región - Lima." Bachelor's thesis, Universidad Nacional Mayor de San Marcos, 2014. https://hdl.handle.net/20.500.12672/11873.

Full text
Abstract:
Publicación a texto completo no autorizada por el autor
El documento digital no refiere asesor
Describe el diseño de una planta de tratamiento de aguas residuales, conformado por Lagunas de Estabilización Facultativas. La cámara de rejas es un dispositivo formado por barras metálicas paralelas, del mismo espesor e igualmente separados. Se destina a la remoción de solidos gruesos en suspensión como cuerpos flotantes. Impide que pasen sólidos, para prevenir obstrucciones en la tubería de descarga a la laguna. El tratamiento primario se lleva a cabo en la Laguna Facultativa Primaria, la cual se diseña principalmente para la remoción de materia orgánica suspendida (SST) y no la obtención de un efluente de alta calidad, el resto pasa a la segunda etapa. La etapa secundaria en la Laguna Secundaria esencialmente es la eliminación de bacterias patógenas, además de su efecto desinfectante, estas lagunas cumplen otros objetivos como son la nitrificación del nitrógeno amoniacal, la eliminación de ciertos nutrientes, la clarificación del efluente y como consecuencia de esto el efluente se encuentra bien oxigenado. Una vez realizado los cálculos para el diseño de la planta podremos comparar, si las aguas ya tratadas pueden ser reutilizables en la agricultura. Se dispondrá la colocación de una Geomembrana HDPE de 1mm de espesor, que impida la filtración e infiltración de las aguas hacia las lagunas.
Trabajo de suficiencia profesional
APA, Harvard, Vancouver, ISO, and other styles
28

Robles, Rázuri Max Rogger. "Planteamiento de solución a la problemática de las aguas residuales de Arequipa metropolitana y diseño de emisores." Bachelor's thesis, Universidad Nacional Mayor de San Marcos, 2010. https://hdl.handle.net/20.500.12672/15429.

Full text
Abstract:
Comprende los estudios a nivel de ingeniería básica de la alternativa seleccionada de un total de catorce como la mejor técnica y económicamente, que cumpla el propósito de recolectar, conducir y tratar las aguas residuales que actualmente son vertidas directamente al río Chili sin ningún tipo de tratamiento previo. La primera fase del proyecto comprendió la identificación de los principales puntos de vertimiento de las aguas residuales al río Chili (que son los principales causantes de las enfermedades gastrointestinales en la provincia) evaluando el grado de contaminación y contenido de materia orgánica mediante la extracción directa demuestras. Se identificaron tres puntos de relevante importancia donde actualmente se vierten las aguas residuales al río los cuales son: colector Alata, colector Arancota y colector Huaranguillo, respectivamente desde aguas arriba hacia aguas abajo. Posteriormente se identificaron los posibles sitios de ubicación para la planta de tratamiento y los trazos preliminares del sistema de intercepción y conducción de las aguas residuales. Las alternativas propuestas comprendieron diferentes sistemas de tratamiento según las áreas aprovechables. Se propuso como alternativas la implementación de tres, dos y una planta para dar solución al problema de los vertimientos. La alternativa recomendada técnica y económicamente comprende dos plantas de tratamiento, una ubicada en el denominado Sitio B (Tunales ) y otra ubicada en la pampa Escalerilla denominada planta Escalerilla, realizando sobre esta los estudios básicos (topografía, geología, geotecnia, hidrología, ambiental) y los diseños a un nivel de ingeniería básica (Plantas de Tratamiento y sus emisores). La planta del Sitio B se encuentra ubicada en la margen izquierda del río Chili, en una terraza ubicada aproximadamente a 500 metros del Sector Los Tunales en el distrito de Tiabaya. El agua residual a ser tratada en esta planta llega a través de un interceptor de 5,239.9 metros de longitud, cuyo diámetro varía entre 1.8 y 1.9 metros. Este emisor (interceptor) como punto de inicio la caja colectora existente del colector Alata en la margen izquierda del río Chili, el trazo se dispone perpendicularmente al río Chili, cruzándolo mediante un acueducto de 360 metros de longitud hacia la margen derecha donde intercepta al colector Arancota continuando su recorrido por la Av. Arancota (Ex - carretera Panamericana) hasta la progresiva 1+800 donde se dispone hacia la izquierda por una serie de terrenos de cultivo y caminos existentes hasta interceptar en esta misma margen al colector Huaranguillo. Desde el inicio del colector en Alata hasta el colector Huaranguillo el colector proyectado (interceptor) tiene un diámetro de 1.8m. A partir de este punto el colector adopta un diámetro de 1.9m hasta llegar al sitio de la Planta. El Emisor (interceptor) está provisto de buzones distanciado como máximo cada 150 metros. Como ya se ha mencionado en párrafos anteriores, las estructuras tanto la Planta del Sitio B (Los Tunales) como el emisor proyectado se encuentra en la margen del río (en el caso de la Planta) o cruzándolo (en el caso del emisor) necesitando realizar un estudio de máximas avenidas así como de un análisis de inundaciones ocasionadas por estas, motivo de la presente trabajo. De igual manera se presentará los criterios y cálculos justificativos para el diseño del emisor proyectado. Cabe mencionar que el tesista además de estar encargado de la supervisión de los trabajos de campo de los estudios básicos, participo en la elaboración del estudio hidrológico, análisis de inundaciones, trazo y diseño del colector.
Trabajo de suficiencia profesional
APA, Harvard, Vancouver, ISO, and other styles
29

Rivera, Helbig Carol Andrea. "Estudio de la efectividad de una nueva configuración tecnológica de tratamiento de aguas residuales, lodos activados plus (La+) : combinación de un biorreactor de membranas y ozonización, desarrollado para reducir la producción de purga de lodos y mejorar la calidad de aguas tratadas." Tesis, Universidad de Chile, 2014. http://repositorio.uchile.cl/handle/2250/149504.

Full text
Abstract:
Tesis Magíster en Bioquímica área de Especialización Ambiental y Memoria para optar al Título de Bioquímica
Reducir la producción de purga de lodos y generar aguas potencialmente reutilizables en los tratamientos de plantas de aguas servidas es crucial en un escenario de escasez hídrica. En este contexto, el objetivo del presente trabajo es evaluar el efecto que produce la combinación de las estrategias lisis-crecimiento críptico (ozonización) y metabolismo de mantención (biorreactor de membrana), que definen la tecnología LA+, en términos de eficiencia en la minimización de la producción de lodos y en el mejoramiento de la calidad del agua tratada obtenida. La línea base se estableció con un sistema de lodos activados convencional (LAC) y se evaluaron los efectos de cada técnica metabólica por separado mediante ozonización (LAO3) y un biorreactor de membrana (BRM). Los resultados muestran que con dosis de 0,04 gO3/gSSTo ó 0,01 gO3/h*[SSVo] el sistema LA+ fue superior a los sistemas LAC, LAO3 y BRM, cumpliendo con los límites establecidos por el DS90 en todos los parámetros evaluados respecto a la calidad del agua tratada generada y además obteniendo una producción de lodos de purga 75% menor que LAC, produciendo 0,22 gSSV/d v/s 0,88 gSSV/d
The reduction of excess sludge production and the generation of potentially reusable water in wastewater treatment plants is critical in a scenario where there is water scarcity. In this context the aim of this work was to evaluate the effect produced by the combination of lysis-cryptic growth (ozonation) and maintenance metabolism (membrane bioreactor) strategies, both of them defining parts of the AS+ technology, in terms of efficiency in minimizing sludge production and improving the quality of obtained treated water. The baseline was established with a conventional activated sludge system (CAS) and the effects of each metabolic technique were evaluated separately during ozonation (ASO3) and while using a membrane bioreactor (MBR). The results showed that with a doses of 0,04 gO3/gSSTo or 0,01 gO3/h*[SSVo], the AS+ system was superior to CAS, ASO3 and MBR systems, complying with the established limits for all parameters given by the DS 90 when evaluated for the quality of the generated treated water and also AS+ achieved a excess sludge production 75% lower than CAS, producing 0,22 gSSV/d v/s 0,88 gSSV/d
APA, Harvard, Vancouver, ISO, and other styles
30

Vilcas, Anco Omar Enrique. "Mejoramiento del sistema de agua potable y construcción del sistema de alcantarillado de los centros poblados de Huaquish, Pocor y Lanchar, distrito de Pararín, provincia de Recuay, departamento de Ancash." Bachelor's thesis, Universidad Nacional Mayor de San Marcos, 2014. https://hdl.handle.net/20.500.12672/10920.

Full text
Abstract:
Publicación a texto completo no autorizada por el autor
El documento digital no refiere asesor
El estudio topográfico fue realizado siguiendo las pautas de la “Norma Técnica para la producción de Cartografía Básica Escala 1:1000 (IGN) V1.0”, de la cual se observa que se puede realizar el trazo de las redes de alcantarillado convencional en los centros poblados de Huaquish y Pocor y estos generaran un perfil longitudinal que sigue una pendiente de un solo sentido con lo cual se tendrá una sola área de drenaje evitándose así proyectar una estación de bombeo de desagües u otro tipo de estructuras que encarecerían el proyecto. Realizado el estudio topográfico se concluye que el centro poblado de Lanchar presenta una pendiente diferente a la pendiente que siguen los trazos de las redes de alcantarillado de los centros poblados de Huaquish y Pocor, además las viviendas se encuentran ubicadas de manera dispersa por lo que se ve conveniente proyectar un Sistema de Disposición Final de Excretas con Biodigestores y no las tradicionales letrinas de hoyo seco o composteras, esto debido a que los Biodigestores presentan una tecnología reciente siendo más funcionales (fácil operación y mantenimiento) y de mejor eficiencia en el tratamiento primario de las aguas residuales. Con la realización del estudio de suelos podemos concluir que el suelo no presenta Sulfatos ni Sales las cuales son perjudiciales ya que deterioran al concreto tradicional (concreto que usa cemento portlannd tipo I para su preparación), de este modo no se haría necesario usar aditivos especiales ni otro tipo de cemento para neutralizar los Sulfatos y Sales. Asimismo el terreno es de tipo normal no presentándose terreno semirocoso ni terreno rocoso, lo cual permite que se obtengan resultados favorables en las pruebas de percolación (se obtuvo un descenso de 5cm en 10 minutos en promedio). La verificación del estudio de fuentes se concluye que la actual fuente de agua tiene cantidad y calidad de agua (que cumple con los parámetros establecidos para agua de consumo humano) requerida para el proyecto.
Trabajo de suficiencia profesional
APA, Harvard, Vancouver, ISO, and other styles
31

Silva, Rivera Wilmer. "Calidad de los efluentes líquidos, en el proceso de optimización de las torres de enfriamiento de la refinería de zinc de Cajamarquilla, periodo 2013-2014." Master's thesis, Universidad Nacional Mayor de San Marcos, 2017. https://hdl.handle.net/20.500.12672/7518.

Full text
Abstract:
Publicación a texto completo no autorizada por el autor
Aborda la calidad de los efluentes líquidos proveniente de las purgas de los sistemas de refrigeración de las torres de enfriamiento N° 1(160K) y N° 2 (320K) ubicadas al sur de la refinería de zinc de Cajamarquilla, propiedad de la Asociación de Regantes del Valle de Jicamarca. La optimización de los sistemas de refrigeración de las torres de enfriamiento N° 1 (160K y Tower tech) y N° (320K) se realizó en tres fases. La primera fase consistió en el acondicionamiento de líneas con la derivación hacia la planta pH 9 con el propósito de reducir el contenido de zinc y sólidos en suspensión y lograr un nivel de eficiencia, para obtener efluentes con las mínimas concentraciones de metales y permitir que su descarga al cuerpo receptor no ocasione efectos adversos en los componentes del ecosistema. La segunda fase consistió en el estudio y aplicación de modernas tecnologías en sistemas de refrigeración, como la Tecnología 3D Trasar, que ayudó a detectar, determinar y evitar incrustaciones, corrosión y actividad microbiológica, a controlar y monitorear el agua de aporte (Make Up) y la purga de las torres de enfriamiento en forma automática. Mejoró la instrumentación de las variables principales de calidad de efluentes líquidos, permitiendo el control y monitoreo continuo en tiempo real de los parámetros de control como potencial de iones de hidrógeno, conductividad, turbidez, ensuciamiento (Fouling) de la celda, temperatura, caudal, entre otros. La tercera fase consistió en mejorar el tratamiento químico de las torres de enfriamiento al reemplazar el inhibidor de corrosión Nalco 8575 y el inhibidor de incrustación Nalco 8300 por el Nalco 3DT 187 y el Nalco 3DT 198, respectivamente. Con la aplicación de esas nuevas tecnologías limpias y sostenibles se logró mejorar estos valores de calidad del efluente y reducción de uso de agua. El ahorro en el consumo de agua fresca en el periodo 2013 a 2015 fue de 50.86% siendo los ciclos de concentración de 2.37 a 3.03 respectivamente; asimismo, entre el 2013 y 2014, se logró disminuir el contenido de Zinc a la salida de la torre en 6.35 % de 2.52 mg/L a 2.36 mg/L.
Tesis
APA, Harvard, Vancouver, ISO, and other styles
32

Suárez, Alvites Alejandro. "Método de superficies de respuesta (MSR) para procesos de optimización aplicado a la filtración de lodos provenientes del sedimentador primario de una planta de tratamiento de aguas residuales (PTAR)." Bachelor's thesis, Universidad Nacional Mayor de San Marcos, 2017. https://hdl.handle.net/20.500.12672/6161.

Full text
Abstract:
Explora la viabilidad técnica de procesar por filtración el lodo proveniente del tratamiento primario de la BRWTP acondicionando el lodo con polímero y diversos soportes de crecimiento. La filtración del lodo es considerada como la etapa previa para disponer el lodo finalmente en un proceso de combustión. El método empleado en el trabajo se conoce como superficie de respuestas (MSR) y se utiliza para los acondicionamientos del lodo con tres sólidos diferentes y el coagulante común.
Tesis
APA, Harvard, Vancouver, ISO, and other styles
33

Carricondo, Antón Juan Manuel. "Utilización de residuos vegetales para la eliminación de fósforo en aguas residuales mediante procesos de adsorción." Doctoral thesis, Universitat Politècnica de València, 2021. http://hdl.handle.net/10251/158614.

Full text
Abstract:
[ES] La presente tesis doctoral tiene como objetivo la utilidad de restos vegetales de origen agrícola y no agrícola para la eliminación de fósforo de las aguas residuales, y con ello reducir la eutroficación del lago de l'Albufera de Valencia, en el este de España. Bajo el concepto de Economía Circular, la cual se basa en reducir la entrada de materiales y la generación de desechos en sistemas productivos, los restos vegetales son utilizados para la producción de energía renovable en plantas de biomasa, una vez incinerados en estas plantas los restos vegetales pasan a ser un residuo, la ceniza. Se han estudiado las cenizas de materiales vegetales agrícolas como es la paja de arroz y los restos de podas de vegetación invasora como es el carrizo, ambos procedentes del Parque Natural de l'Albulfera de Valencia. Además, se han utilizado cenizas de una planta de biomasa de la comarca del Rincón de Ademuz, en el interior de la provincia de Valencia, alimentada con restos vegetales agrícolas como son la paja de trigo, paja de cebada y madera de plantaciones de paulonia cultivadas para la producción de bioenergía. Para poder reducir la concentración de fósforo del agua, se ha seleccionado el proceso que hoy en día más posibilidades tiene de ser un sistema de bajo coste y alta eficiencia como es la adsorción. Mediante las isotermas de adsorción de Langmuir, Freundlich y Tempkin se han determinado las capacidades de adsorción de fósforo, llegando a una reducción de fosforo de hasta casi del 99%, siendo la isoterma de Langmuir la que mejor ajuste posee al proceso de adsorción de fósforo. Por último, el residuo producido en el proceso de depuración, que es la ceniza con alta concentración de fosforo, puede ser utilizada para la fertilización de campos agrícolas.
[CAT] La present tesi doctoral té com a objectiu la utilitat de restes vegetals d'origen agrícola i no agrícola per a l'eliminació de fòsfor de les aigües residuals, i amb això reduir l'eutrofització del llac de l'Albufera de València, en l'est d'Espanya. Sota el concepte d'Economia Circular, la qual es basa a reduir l'entrada de materials i la generació de deixalles en sistemes productius, les restes vegetals són utilitzats per a la producció d'energia renovable en plantes de biomassa, una vegada incinerats en aquestes plantes les restes vegetals passen a ser un residu, la cendra. S'han estudiat les cendres de materials vegetals agrícoles com és la palla d'arròs i les restes de podes de vegetació invasora com és el canyís, tots dos procedents del Parc Natural de l'Albulfera de València. A més, s'han utilitzat cendres d'una planta de biomassa de la comarca del Racó d'Ademús, a l'interior de la província de València, alimentada amb restes vegetals agrícoles com són la palla de blat, palla d'ordi i fusta de plantacions de paulonia cultivades per a la producció de bioenergia. Per a poder reduir la concentració de fòsfor de l'aigua, s'ha seleccionat el procés que hui dia més possibilitats té de ser un sistema de baix cost i alta eficiència com és l'adsorció. Mitjançant les isotermes d'adsorció de Langmuir, Freundlich i Tempkin s'han determinat les capacitats d'adsorció de fòsfor, arribant a una reducció de fòsfor de fins a quasi del 99%, sent la isoterma de Langmuir la que millor ajust posseeix al procés d'adsorció de fòsfor. Finalment, el residu produït en el procés de depuració, que és la cendra amb alta concentració de fòsfor, pot ser utilitzada per a la fertilització de camps agrícoles.
[EN] The objective of this doctoral thesis is the use of vegetable remains of agricultural and non-agricultural origin for the elimination of phosphorus from wastewater, and thereby reduce the eutrophication of the lagoon of l'Albufera de Valencia, in eastern Spain. Under the concept of Circular Economy, which is based on reducing the entry of materials and the generation of waste in production systems, plant remains are used for the production of renewable energy in biomass plants, once the remains are incinerated in these plants. Vegetables become a residue, the ash. The ashes of agricultural plant materials such as rice straw and the remnants of pruning of invasive vegetation such as reed have been studied, both from the Natural Park of l'Albulfera de Valencia. In addition, ashes from a biomass plant from the Rincón de Ademuz region, in the interior of the province of Valencia, have been used, fed with agricultural plant remains such as wheat straw, barley straw and wood from cultivated paulownia plantations for the bioenergy production. In order to reduce the phosphorus concentration of the water, the process that today has the most possibilities of being a low-cost and high-efficiency system, such as adsorption, has been selected. By means of the adsorption isotherms of Langmuir, Freundlich and Tempkin, the phosphorus adsorption capacities have been determined, reaching a reduction of phosphorus of up to almost 99%, being the Langmuir isotherm the one that best fits the phosphorus adsorption process. Finally, the residue produced in the purification process, which is ash with a high concentration of phosphorus, can be used for the fertilization of agricultural fields.
Carricondo Antón, JM. (2020). Utilización de residuos vegetales para la eliminación de fósforo en aguas residuales mediante procesos de adsorción [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/158614
TESIS
APA, Harvard, Vancouver, ISO, and other styles
34

Chávez, Sumarriva Israel Juan. "Adsorción del dodecilbenceno sulfonato sódico usando grafenos." Doctoral thesis, Universidad Nacional Mayor de San Marcos, 2018. https://hdl.handle.net/20.500.12672/8640.

Full text
Abstract:
Publicación a texto completo no autorizada por el autor
El documento digital no refiere asesor
Estudia la adsorción del surfactante sódico dodecilbenceno sulfonato (SDBS) usando grafeno (rGO) para eliminar este aniónico tensoactivo del agua para evitar la contaminación por este tipo de tensoactivo. El problema es que los surfactantes (detergentes) se eliminan en las aguas residuales causando contaminación del agua por eutrofización, un surfactante aniónico es ampliamente utilizado en la industria química (papel, textil, petróleo, etc.) y domésticamente es el surfactante de sodio dodecilbenceno sulfonato, que debe eliminarse de las aguas residuales. Se presenta un estudio de detalle del mecanismo de adsorción del dodecilbenceno de sodio sulfonato (SDBS) en solución acuosa sobre grafeno (rGO), se consideran tanto datos termodinámicos y cinéticos. Se realiza una comparación entre la adsorción de sitio único y dual; se demuestra que el mecanismo de sitio dual está fuertemente favorecido sobre el sitio único convencional. Para este propósito, la ecuación isoterma para la adsorción de sitio dual se deriva por primera vez y se reportan los coeficientes de la tasa de adsorción y desorción de sitio dual, en base a un enfoque de análisis de regresión mejorado. Se identifica una temperatura óptima de 298 K, considerando las cantidades iniciales de SDBS bajas y altas. Además, se demuestra que la presencia inicial de cloruro de sodio permite reducir el tiempo de contacto de 30 a 10 horas. Por lo tanto, el sistema de adsorción bajo investigación se muestra atractivo para el tratamiento de corrientes de aguas residuales de relevancia industrial. Como resultado de esta investigación, se publicó un artículo científico titulado Nuevos conocimientos en el tratamiento de aguas residuales con grafeno: adsorción de doble sitio por sodio dodecilbencenosulfonato en la revista Industrial & Engineering Chemistry Research, Volumen 55, páginas 9387-9396, 2016.
Tesis
APA, Harvard, Vancouver, ISO, and other styles
35

Puente, Rodríguez Adán Edmundo. "Optimización del sistema de tratamiento y disposición sanitaria de aguas residuales industriales para vertimiento clase III, provenientes de la boca mina del nivel 250 (EF 03) al río San José." Master's thesis, Universidad Nacional Mayor de San Marcos, 2019. https://hdl.handle.net/20.500.12672/10782.

Full text
Abstract:
Estudia las habilidades blandas obtenidas por los profesionales PSP y las compara con la industria mediante portales de anuncios de trabajo y encuestas, notándose como resultado la importancia de este método. Se suma una propuesta de integración a la malla curricular de una carrera de Ingeniería de Software a modo de caso. Cada persona que participa en el proceso de software debe hacerlo con procesos maduros, de manera que pueda competir en una industria que solicita calidad en sus productos, para ello el SEI propuso una metodología personal denominada PSP. En Latinoamérica existen más de 1200 profesionales certificados en esta metodología, pero el número debería ser mayor ya que según la teoría son las formas fundamentales bajo las que debería proceder un ingeniero de software en su profesión.
Tesis
APA, Harvard, Vancouver, ISO, and other styles
36

Ríos, Rivera Anita Cecilia. "Eficiencia de fibras naturales, cabuya (Furcraea andina) y paja de trigo (Triticum vulgari) como biofiltros alternativos en el proceso de desnitrificación de aguas residuales de piscícolas de trucha arcoíris en la localidad Juan de Velasco." Doctoral thesis, Universidad Nacional Mayor de San Marcos, 2017. https://hdl.handle.net/20.500.12672/6225.

Full text
Abstract:
Publicación a texto completo no autorizada por el autor
Plantea el uso de las fibras naturales andinas cabuya (Furcraea andina) y paja de trigo (Triticum vulgari) como soporte bacteriano de biorreactores anaerobios UASB, para procesos de desnitrificación de aguas residuales de piscícolas de truchas arcoíris en la zona alto andina de la localidad Juan de Velasco en Ecuador. Evalúa tanto la capacidad de desnitrificar las aguas residuales de acuicultura como la de remover metales pesados, mediante el uso combinado de biofilms soportados por fibras naturales, en condiciones controladas y acondicionamiento previo del medio bacteriano. Diseña nueve biofiltros a escala piloto para la remoción de contaminantes de las aguas residuales de piscícolas de truchas arcoíris. Determina si la incubación de la microbiota con pseudomonas acelera la adaptación de la población bacteriana en las fibras naturales en seis biofiltros. Determina la tasa de desnitrificación de los efluentes de las piscícolas de los biofiltros, las diferentes alturas de la columna de los biofiltros orgánicos en un proceso anaerobio, la altura del biofiltro necesario para la descontaminación de los efluentes de las piscícolas y si el biofiltro con la fibra cabuya–pseudomonas aisladas contribuye en la remoción de metales pesados que provienen de la ceniza de la zona volcánica del sector estudiado. Evalúa la degradación de las fibras naturales como medios filtrantes mediante el análisis de los cambios en las propiedades físicas y químicas, la calidad sanitaria del efluente de los biofiltros anaerobios, con cargas hidráulicas constante, para determinar si cumplen con los criterios que marca la normatividad ambiental ecuatoriana.
Tesis
APA, Harvard, Vancouver, ISO, and other styles
37

Silva, Casas Megy Ninoska. "Extracción del mucílago de la penca de tuna y su aplicación en el proceso de coagulación-floculación de aguas turbias." Bachelor's thesis, Universidad Nacional Mayor de San Marcos, 2017. https://hdl.handle.net/20.500.12672/7155.

Full text
Abstract:
Busca obtener altos rendimientos de extracción del mucilago de la penca de tuna mediante la aplicación de un diseño de experimentos, caracterizarlo químicamente y utilizarlo eficientemente en la remoción de la turbidez en aguas turbias. Determina, mediante un análisis de los trabajos de la literatura especializada, los factores más influyentes en el proceso de extracción del mucílago del Opuntia ficus Indica. Aplica un diseño factorial fraccionado para obtener un alto rendimiento en la extracción del mucilago. Realiza la caracterización del mucilago por medio de técnicas químicas y/o físicas. Determina la concentración óptima por medio de la prueba de jarras, aplicando el diseño factorial por bloques para obtener el máximo de remoción de la turbidez del agua.
Tesis
APA, Harvard, Vancouver, ISO, and other styles
38

Chaw, Namuche Daniel Augusto. "Servicios ambientales y percepción ambiental en un ecosistema urbano. Estudio de Caso: el uso y tratamiento de aguas residuales en el Colegio de La Inmaculada." Master's thesis, Pontificia Universidad Católica del Perú, 2012. http://tesis.pucp.edu.pe/repositorio/handle/123456789/1664.

Full text
Abstract:
A lo largo de estos últimos años, las ciudades o centro urbanos juegan —y seguirán jugando— un rol importante en la economía mundial. Estos centros urbanos no solamente se caracterizan por una población aglomerada sino por la gran complejidad social que esta misma ha creado para atender sus propias necesidades. Así, la ciudad se gobierna por un determinado sistema político normativo que regula o establece un orden en otros sistemas. En ese sentido, encontramos regulaciones para el servicio de transporte público y privado, para el acceso a servicios básicos: agua, alcantarillado, energía eléctrica, entre otros servicios.
Tesis
APA, Harvard, Vancouver, ISO, and other styles
39

Onofre, Aquino Edwin Francisco. "Propuesta técnica de gestión ambiental sostenible para el aprovechamiento de lodos que provienen de las plantas de tratamiento de aguas residuales domésticas en campamentos mineros del Perú." Master's thesis, Pontificia Universidad Católica del Perú, 2018. http://tesis.pucp.edu.pe/repositorio/handle/123456789/13374.

Full text
Abstract:
El trabajo de investigación que a continuación se presenta, es el resultado de la investigación del estudio analítico del manejo de lodos de las plantas de tratamientos de aguas residuales domésticas de las empresas mineras del Perú, con el propósito de brindar alternativas técnicas que estén en concordancia con el cumplimiento legal, la responsabilidad ambiental, la convivencia armónica con los grupos de interés (stakeholders) y la mejora en la reputación. En este sentido se analizaron los fundamentos teóricos, técnicos y la experiencia de tratamientos de lodos en otros países; se ha podido evidenciar que en países como EEUU, Chile, Brasil, España y Colombia existen normativas legales que respaldan el manejo y uso de los lodos en las actividades Forestales y Agrícolas que se diferencian en categorías por el nivel de contaminantes y posible afección a la salud humana. Como resultado del presente estudio se evidenciaron que muchas Empresas Mineras aprovechan los vacíos legales para no implementar las plantas de tratamiento de aguas residuales y muchas de ellas solo llegan a cumplir con el tratamiento primario y muy pocas el tratamiento de nivel secundario; llegando a disponer los lodos en las presas de relaves o como hayan sido aprobados en su Instrumento de Gestión Ambiental; en consecuencia están dirigidas a cubrir los lodos y/o alejarlas del olfato humano. Finalmente el presente trabajo de investigación, propone alternativas de aprovechamiento de los lodos porque constituyen un insumo primario fundamental para la obtención de sub productos como abono orgánico, fertilizante foliar y biogás. De acuerdo al análisis la no implementación no pasa por la limitación económica sino por el desconocimiento de la parte técnica, falta de experiencia en el tratamiento de lodos en el Perú y porque las entidades fiscalizadoras no generan presión para el cumplimiento del Decreto Legislativo N° 1278 y menos la resolución ministerial N° 128-2017 – Vivienda
Trabajo de investigación
APA, Harvard, Vancouver, ISO, and other styles
40

Bellido, Suica Javier Oscar. "Cálculo hidráulico para la planta de tratamiento de aguas servidas para la ciudad de Huari." Bachelor's thesis, Universidad Nacional Mayor de San Marcos, 2010. https://hdl.handle.net/20.500.12672/15006.

Full text
Abstract:
El documento digital no refiere asesor
Publicación a texto completo no autorizada por el autor
El objetivo del proyecto es mejorar la calidad de vida de la población de la ciudad de Huari con la rehabilitación de su sistema de colección y la construcción de un planta de tratamiento de aguas servidas que permitirán un adecuado tratamiento de las aguas servidas que serán vertidas en el cauce del río Huari y así evitar la contaminación del mismo que es uno de los factores de enfermedades en la población y el ganado de la ciudad de Huari, además que parte del agua servirá para el regadío de cultivos tales como forrajes y árboles. El objetivo específico de este trabajo es proveer la información necesaria para determinar las bases de diseño para la construcción de la planta de tratamiento de aguas servidas de la ciudad de Huari. Para esto, el proyecto se ha basado en la información histórica censal y en la información hidrológica de la ciudad de Huari.
Trabajo de suficiencia profesional
APA, Harvard, Vancouver, ISO, and other styles
41

Uribe, Erazo Javier Martín. "Sistema de re-inyección de agua producida aplicada a la plataforma Offshore Z1-8-A." Bachelor's thesis, Universidad Nacional Mayor de San Marcos, 2013. https://hdl.handle.net/20.500.12672/12574.

Full text
Abstract:
Describe la implementación del nuevo sistema de re-inyección de agua de formación, en la plataforma albacora de BPZ exploración y producción S.R.L. El Lote Z1 es un área de concesión para exploración y explotación de hidrocarburos, ubicada sobre el zócalo continental en el Noroeste del Perú, frente a la costa de los distritos de Tumbes, Zarumilla y Zorritos, en la región Tumbes; tiene una extensión de 2 994,67 km2. La plataforma Z1-8-A Albacora es una instalación de exploración y explotación de hidrocarburos, ubicada en el Lote Z1; se encuentra ubicada en el mar, a 29 km de la población de Zorritos y a 25 km a la Caleta La Cruz. BPZ Exploración & Producción S.R.L. en adelante BPZ cuenta actualmente con facilidades de producción de agua, gas Asociado y crudo en plataforma AX08-Albacora ubicada en el Lote Z1-8-A.
Trabajo de suficiencia profesional
APA, Harvard, Vancouver, ISO, and other styles
42

García, Tito Zonia Susy. "Descripción del proceso constructivo y control de calidad del emisor submarino Taboada." Bachelor's thesis, Universidad Nacional Mayor de San Marcos, 2014. https://hdl.handle.net/20.500.12672/12762.

Full text
Abstract:
El objetivo del presente trabajo fue describir el Proceso Constructivo y Control de Calidad que se realizó al Emisario Submarino desde su etapa inicial hasta su puesta en Marcha.
Trabajo de suficiencia profesional
APA, Harvard, Vancouver, ISO, and other styles
43

Orozco, Romero Karen Lisette. "Biodegradación de colorante azul directo por consorcios bacterianos aislados de un efluente textil de Lima, Perú." Bachelor's thesis, Universidad Nacional Mayor de San Marcos, 2018. https://hdl.handle.net/20.500.12672/8807.

Full text
Abstract:
La industria textil anualmente genera 280 000 toneladas de efluentes contaminados con colorantes azoico, que son tóxicos, cancerígenos y mutagénicos; por ende, requiere soluciones eficientes de descontaminación. Se diseña y caracteriza un consorcio microbiano con excelente capacidad de degradación de azul directo, que podría ser usado para la descontaminación de efluentes. Se colectaron en total 12 muestras: 6 de aguas residuales y 6 de fango acumulado en el punto de confluencia del efluente, ambas colectadas de una fábrica textil ubicada en la región de Lima. Se seleccionaron 2 cultivos debido a su mejor respuesta a la decoloración in vitro en medio Zhou y Zimmerman (ZZ). Se aislaron 5 cepas bacterianas, y con ello se construyeron 27 consorcios. Se seleccionó el consorcio CP23, pues resultó tener mejor rendimiento promedio. Se extrajo el DNA genómico de las 2 cepas bacterianas que conformaban el consorcio CP23, y se secuenciaron mediante tecnología de Illumina MiSeq®. Las cepas fueron identificadas como Enterococcus gallinarum PL23 y Stenotrophomonas maltophilia LS23. Se evaluaron las cinéticas de crecimiento de las cepas puras y cuando conformaban el consorcio CP23 en medio ZZ suplementado con 100 ppm de Azul Directo a través del recuento en cámara PetroffHausser. Se obtuvo una mayor velocidad de crecimiento (μ) de parte del consorcio, siendo esta de 2.6 +/- 0.05 x 10-2 min-1, y un menor tiempo de duplicación, el cual fue de 26.5 +/- 0.5 min. Se optimizaron los parámetros más importantes de biodegradación in vitro cuantificados mediante espectrofotometría UV-Vis, estos fueron 0,5% de glucosa, 1% de extracto de levadura, pH 8, 37ºC, 2 x 106 UFC x ml-1 de inóculo inicial y 100 ppm de colorante, obteniéndose un rendimiento promedio de 91.53% a las 6 horas. Además, se evaluaron cinéticas de decoloración del consorcio CP23 con otros colorantes azo: amarillo drimaren, rojo drimaren, azul marino remazol, azul remazol, amarillo oro remazol, azul turquesa remazol y rojo remazol, con rendimientos de más del 95% en su mayoría. Los resultados representan el primer estudio en el país sobre el diseño y caracterización de consorcios microbianos con capacidad de degradación de colorantes azo, aislados de efluentes textiles en Perú con potencial uso en biorremediación de aguas residuales.
Tesis
APA, Harvard, Vancouver, ISO, and other styles
44

Atte, Oyarce Shadia Suheily. "Implementación de un módulo de tratamiento de efluentes mineros que contienen metales pesados." Bachelor's thesis, Universidad Nacional Mayor de San Marcos, 2021. https://hdl.handle.net/20.500.12672/17183.

Full text
Abstract:
La presente tesis, propone el diseño, desarrollo y utilización de un módulo de tratamiento de efluentes mineros utilizando esponjas de poliuretano. Su actividad principal es llevar los efluentes de la actividad minera, con alto contenido de metales pesados, hasta límites permisibles. Tras una evaluación inicial de un conjunto de unidades mineras, se localizó el estudio en la Mina Julcani, en donde se tomaron y analizaron las muestras de efluentes, para caracterización y análisis. Luego, se llevó a cabo la búsqueda de floculantes para un tratamiento primario, para luego llevarlos a un biorreactor con esponjas de poliuretano para el tratamiento correspondiente. La presente tesis, demuestra aplicaciones prácticas de algunos conceptos relacionados a la biorremediación y aplicación técnica, en el diseño del módulo, por lo tanto, los métodos utilizados que derivan de concepto sobre la teoría de biorremediación, nos ayudan al diagnóstico de problemas en las unidades mineras, que pueden ser aplicados en unidades similares y nos ayudan también a encontrar la solución a estos problemas diagnosticados.
APA, Harvard, Vancouver, ISO, and other styles
45

Fuentes, Quispe Ivette Alejandra. "Caracterización fisiológica y genómica de dos cepas nativas del género Shewanella con potencial biodegradador de colorantes azoicos." Bachelor's thesis, Universidad Nacional Mayor de San Marcos, 2019. https://hdl.handle.net/20.500.12672/10415.

Full text
Abstract:
La industria textil libera al ambiente grandes cantidades de aguas residuales que, entre otros varios contaminantes, contienen colorantes azo en su composición, los cuales son compuestos tóxicos, carcinogénicos y mutagénicos que afectan negativamente la vida acuática y la calidad del agua. El presente estudio tuvo por objetivo caracterizar a nivel fisiológico y genómico cepas nativas con potencial de degradación de colorantes azo obtenidas de un efluente de industria textil de Lima, Perú. Se aplicó el método de la microplaca a doce aislados bacterianos para su selección en base a su respuesta positiva a la decoloración de tres colorantes azo: Azul directo 71, Rojo remazol RGB y Amarillo Oro Remazol RGB. La actividad decolorante de las cepas seleccionadas fue evaluada mediante espectrofotometría UV-Visible en medio ZZ con el colorante respectivo a 100 ppm y en condiciones de microaerofilia durante 24 horas. El secuenciamiento de los genomas se realizó utilizando la tecnología HiSeq 2500 de Illumina, el ensamblaje de novo con el software SPAdes, la extensión de los contigs y reparación de gaps a través de los programas ABACAS e IMAGE y la anotación con Prokka. Las dos cepas con mejor eficiencia de degradación correspondieron a Shewanella sp. LC-2 y Shewanella sp. LC-6, ambas identificadas mediante análisis filogenómico resultando muy cercanas al grupo filogenético de Shewanella sp. FDAARGOS_354. Las cepas mostraron una actividad decolorante frente a Azul Directo 71, Rojo Remazol y Amarillo Remazol con porcentajes de 94.42, 94.79, 91.67 para Shewanella sp. LC-2 y 94.37, 94.92, 83.24 para Shewanella sp. LC-6 a las 24 h. Asimismo, los genomas de Shewanella sp. LC-2 y LC-6 revelaron la presencia de genes que codifican azorreductasas dependientes de NADH, peroxidasas decoloradoras de tinte (DyPs), genes implicados en la desaminación, asimilación de sulfatos, reducción de nitratos y metales pesados, como también en la degradación de benzoatos, catecol y gentisato. Se concluye que las cepas Shewanella LC-2 y LC-6 tienen una actividad metabólica eficaz para la decoloración de Azul directo 71, Rojo remazol RGB y Amarillo Oro Remazol RGB, presentan versatilidad catabólica y son de potencial aplicación en la biorremediación de aguas residuales textiles.
Universidad Nacional Mayor de San Marcos (Lima). Vicerrectorado de Investigación y Posgrado
Perú. Ministerio de la Producción. Programa Nacional de Innovación para la Competitividad y Productividad (Innóvate Perú). Fondo para la Innovación, la Ciencia y la Tecnología (FINCyT)
Tesis
APA, Harvard, Vancouver, ISO, and other styles
46

Riffo, Rivas Javiera Pilar. "Análisis de ciclo de vida para una planta de tratamiento de aguas residuales: Potencial de calentamiento global generado por PTAR Talagante." Tesis, Universidad de Chile, 2017. http://repositorio.uchile.cl/handle/2250/148239.

Full text
Abstract:
Ingeniera Civil Química
El cambio climático es un problema ambiental progresivo que afecta a nivel global a la sociedad y al ecosistema. Es provocado por las emisiones antropogénicas de Gases de Efecto Invernadero (GEI), y puede ser contenido solo mediante la reducción sustancial y continua, de tales emisiones. En este contexto, se aplica la herramienta de Análisis de Ciclo de Vida sobre el proceso de tratamiento de aguas residuales de la planta Talagante, enfocado en la emisión de GEI y, por lo tanto, en el Potencial de Calentamiento Global. Este análisis se realiza con el objetivo de evaluar ambientalmente el escenario del proceso actual y un escenario futuro, con foco en la gestión energética, a fin de, identificar las actividades que posean un mayor impacto y recomendar acciones que apunten a disminuir dicho impacto sin afectar la operación normal de la planta. Se analizan tres escenarios: el primero es el actual donde se combustiona el 40% del biogás en caldera para abastecer de energía al biodigestor y el excedente en antorcha; en el segundo, escenario el 100% del biogás es combustionando en un motor de cogeneración que produciría energía eléctrica para la planta y energía térmica para el biodigestor; el tercer escenario corresponde al escenario proyectado al año 2024, que comprende la ampliación de la planta en un módulo de la línea de agua. El resultado del análisis muestra que el total de las emisiones del escenario base (año 2016) fue de 5.100 tCO2eq. En el nuevo escenario, con cogeneración, se disminuye en un 17% las emisiones anuales de la planta. El tercer escenario se obtiene un total de 5.000 tCO2eq para el año 2024. Las emisiones directas de la planta contribuyen sobre el 60% del total de las emisiones del sistema en todos los escenarios analizados. La emisión más significativa corresponde al óxido nitroso que proviene desde el tratamiento biológico de la planta, aportando más del 70% de las emisiones directas en todos los escenarios analizados. Estas emisiones, al estar dentro del campo se acción directo de la empresa, poseen un alto potencial de disminución. En función de los resultados, se definieron estrategias de mitigación para las emisiones directas de óxido nitroso. Se generaron tres recomendaciones: la primera es la realización de campañas de medición de óxido nitroso, la segunda es la optimización de la aeración del tratamiento biológico, y la tercera es la implementación de la tecnología Anammox sobre las aguas de rechazo. Como proyección se sugiere considerar el Potencial de Calentamiento Global en la toma de decisiones de la empresa. De esta forma todos los proyectos realizados pueden contribuir a la disminución de la emisión de GEI, y, con ello, a la contención del cambio climático.
APA, Harvard, Vancouver, ISO, and other styles
47

Cortes, Velázquez Jennifer, Hinojos Ana Marcela Gómez, and Medina Eduardo Campos. "Propuesta de un sistema de biofiltración de cromo hexavalente en agua, utilizando olote de maíz." Tesis de Licenciatura, 2015. http://148.215.1.179/handle/20.500.11799/23558.

Full text
Abstract:
Contiene imágenes, cuadros y esquemas
El objetivo principal de esta investigación fue llevar a cabo una bioadsorción del Cr (VI) presente en soluciones sintéticas, utilizando un sistema de filtración biológica con olote de maíz, de la comunidad de San Lorenzo Huitzizilapan.El sistema de biofiltración fue construido en dos etapas en la que cada una contenía el biomaterial, las soluciones preparadas a diferentes concentraciones de Cr (VI) se hicieron pasar por el sistema de doble biofiltración, posteriormente se llevó a cabo la cuantificación del Cr (VI) en las soluciones obtenidas, utilizando la técnica de Espectrofotometría de UV y de Absorción Atómica, con los resultados obtenidos de ambas técnicas se pudo comprobar que el Cr (VI) no fue adsorbido en su totalidad por el olote, sino que un parte importante se había reducido a Cr (III).
APA, Harvard, Vancouver, ISO, and other styles
48

Tenorio, Juarez Fredy. "Efectos del agua residual y propuesta para el desarrollo local sostenible: caso la cuenca arroyo el muerto, Ocoyoacac, México." Tesis de Licenciatura, 2014. http://ri.uaemex.mx/handle/20.500.11799/30965.

Full text
Abstract:
Esta investigación aborda el tema de los efectos del agua residual y las estrategias de manejo en una micro cuenca denominada El Muerto en Ocoyoacac, México, como respuesta a una problemática estudiada previamente por investigadores de la Universidad Autónoma del Estado de México. De tal manera que esta investigación forma parte del proyecto de investigación titulado: Programa de manejo sustentable del agua residual Cuenca Arroyo El Muerto, en Ocoyoacac, Capulhuac y Tianguistenco, Estado de México del cuerpo académico: Desarrollo Ambiental y Procesos de Configuración Territorial, en la línea de Recursos Naturales para la Actividad Económica Regional y Transformaciones Territoriales con clave de registro: UAEM-CA-152, por lo que, parte de la información presentada en esta investigación surge del desarrollo de dicho proyecto.
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!

To the bibliography