To see the other types of publications on this topic, follow the link: Air heater leakage.

Journal articles on the topic 'Air heater leakage'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 30 journal articles for your research on the topic 'Air heater leakage.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse journal articles on a wide variety of disciplines and organise your bibliography correctly.

1

Tong, Ying, Wei Zhong, Yan Ling Wu, and Shui Guang Tong. "The Study on Heat Transfer Model and Algorithm of Multi-Sectional Regenerative Air Heater in Power Plant Boiler Based on Analytical Method." Applied Mechanics and Materials 448-453 (October 2013): 3229–33. http://dx.doi.org/10.4028/www.scientific.net/amm.448-453.3229.

Full text
Abstract:
Tri-sectional regenerative air heater is used widely because of its compactness and better performance. Study on the matching analytical calculation method of heat transfer is rarely carried out because of the complicated heat transfer process. This paper developed a model to solve the heat transfer calculation of multi-sectional regenerative air heaters, which usually have several layers. Then we designed the computational procedure to carry out the model. One example of a tri-sectional regenerative air heater with hot layer and cold layer shows the effectiveness of the algorithm, and the res
APA, Harvard, Vancouver, ISO, and other styles
2

Zhao, Zhen Ning, Jing Jing Wang, Zhen Zhou Zhao, and Qing Feng Zhang. "Investigation of Exhaust Gas Temperature Correction Methods for the Change of Air Inlet Temperature." Advanced Materials Research 586 (November 2012): 342–48. http://dx.doi.org/10.4028/www.scientific.net/amr.586.342.

Full text
Abstract:
The exhaust gas temperature correction for the change of air inlet temperature is the most significant correction for boiler performance test. However, in ASME and China GB standard, the regulations of the correction formulas are different, which brings about some misunderstanding in actual use. In this paper, the correction formulas are derived and analyzed. What’s more, the application conditions are summed up and described as follows. Firstly, the top and side of the air heater must be in good sealing ability, for which the air leakage can be ignored. Secondly, the air inlet temperature mus
APA, Harvard, Vancouver, ISO, and other styles
3

S, Rinto Muhaimin, and Abdul Ghofur. "ANALISIS PERFORMA PRIMARY AIR HEATER (PAH) PLTU ASAM ASAM UNIT I – KALIMANTAN SELATAN." JTAM ROTARY 1, no. 2 (2019): 173. http://dx.doi.org/10.20527/jtam_rotary.v1i2.1747.

Full text
Abstract:
Power plan has an important role in the electricity supply bussiness, one of them is PLTU Asam Asam which is Unit Pelaksana Pembangkitan Asam Asam. By using fuel coal fired type, this work continously to generate maximum power in generating electricity. In terms working to have maximum power continuously in boiler, Boiler have equipment Primary Air Heater (PAH) to repairing the efficiency. To get best performance Primary Air Fan (PAH) is doing routine maintenance.The Effect is routine maintenance for repairing, abrasive and corrosive material Primary Air Fan (PAH) to be air leakage. This final
APA, Harvard, Vancouver, ISO, and other styles
4

Jassim, R. K., B. A. Habeebullah, and A. S. Habeebullah. "Exergy analysis of carryover leakage irreversibilities of a power plant regenerative air heater." Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy 218, no. 1 (2004): 23–32. http://dx.doi.org/10.1243/095765004322847062.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Zaki, M. Faza Ghani, and Abdul Ghofur. "ANALISA EFEKTIVITAS HEAT TRANSFER SAH PLTU DENGAN METODE ASME 4.0 dan 4.3." JTAM ROTARY 2, no. 1 (2020): 39. http://dx.doi.org/10.20527/jtam_rotary.v2i1.2003.

Full text
Abstract:
Pemanas udara adalah salah satu peralatan tambahan yang sangat penting dalam penggunaan perpindahan panas dalam boiler, di mana peralatan ini berfungsi untuk memanaskan udara untuk pembakaran dengan menggunakan panas dari sisa gas panas dari pembakaran sebelum dikirim ke cerobong asap. Untuk menjaga kinerja pemanas udara, maka analisis efektivitas perpindahan panas pada pemanas udara dilakukan dengan uji kinerja menggunakan metode ASME PTC 4.0 dan ASME PTC 4.3. Pada data commissioning, SAH unit 1 memiliki efisiensi sebesar 58,69%. Namun, dari hasil analisis penelitian perpindahan panas di Seco
APA, Harvard, Vancouver, ISO, and other styles
6

Zhang, Qing Feng, Zhen Xin Wu, and Zhen Ning Zhao. "Analysis of Exhausting Flue Gas Temperature Abnormal Accompanied with the Boiler Load Changing." Advanced Materials Research 805-806 (September 2013): 1836–42. http://dx.doi.org/10.4028/www.scientific.net/amr.805-806.1836.

Full text
Abstract:
Based on the heat-transfer principle of air pre-heater, the influence mode of the changes of the air flow, the flue gas flow, the air leakage in different locations, to the temperature of the hot air and the exhausting gas was researched. The problem of a pulverized coal fired boiler, No.2, of a Thermal Power Plant, which the deviation of exhausting flue gas temperature increased to an abnormal extend when the boiler load rise up quickly was analyzed, the fault position and fault reason were located exactly, and the fault was eradicated by equipment maintenance at last. The results of this stu
APA, Harvard, Vancouver, ISO, and other styles
7

Wu, Yi Min. "Anti-Freezing through Drainage Ensured by Heating with Double Thermal Resources for Construction Joints of Tunnels in Cold Area." Advanced Materials Research 168-170 (December 2010): 2648–53. http://dx.doi.org/10.4028/www.scientific.net/amr.168-170.2648.

Full text
Abstract:
A new anti-freezing method for construction joints in tunnels is put forward through effective drainage ensured by heating with warm air or ribbon heater. The heating system is intelligently controlled according to the monitoring and analysis of the surface temperature of the secondary lining. This method is characterized as the following: (1) preventing leakage without pressure increase is realized through effective drainage at the back of secondary lining with special drainable channels; (2) alternative heating resources including warm air and electrical energy are offered to heat the region
APA, Harvard, Vancouver, ISO, and other styles
8

Lin, Jium Ming, and Cheng Hung Lin. "A Novel RFID-Based Thermal Convection Accelerometer with Heater and Thermal Piles Deposited by E-Gun Focused on Mixing Powders of Metals." Applied Mechanics and Materials 364 (August 2013): 262–66. http://dx.doi.org/10.4028/www.scientific.net/amm.364.262.

Full text
Abstract:
This paper proposes an innovated method to integrate an active RFID tag with a thermal convection accelerometer with heater and thermal piles deposited on a flexible substrate by E-gun, thus it is a wireless sensor for easy usage in many fields. The other advantages of the new device are as: (1) The thermal conductivity (λ148W/(mK)) of the traditional Si is about 25 times of the proposed polyimide substrate (λ6-0.17W/(mK)), thus the power leakage through the substrate is reduced. (2) The heaters and the thermal piles are deposited by E-gun focused on a target of mixing powders of metals on the
APA, Harvard, Vancouver, ISO, and other styles
9

Yuliarto, Brian, Mardiana Silvia, Muhammad Iqbal, and Nugraha. "Fabrication of LP Gas Leakage Detector Systems Based on Modified Nanostructured ZnO Thin Film." Advanced Materials Research 364 (October 2011): 206–10. http://dx.doi.org/10.4028/www.scientific.net/amr.364.206.

Full text
Abstract:
The liquid petroleum (LP) gas leakage detector was successfully fabricated using modified nanostructured ZnO thin film as the sensitive layer. The detector consists of ZnO sensitive layer, a heater, a comparator, a transistor, an LED and a buzzer. The detector has the switch system where the comparator can change the current through the LED and buzzers when the LP gas is detected. The ZnO thin films were fabricated by sol gel method using chemical bath deposition technique at moderate temperature on an alumina substrate with electrode contacts. This sensors system allows us to produce LP gas s
APA, Harvard, Vancouver, ISO, and other styles
10

Zhou, Yong Yan, Xiao Cui Guo, Li Li, and Zhi Ping Zhu. "Causes Analysis and Treatment Measures for Excess SiO2 Content in a 300MW Unit Boiler Water." Advanced Materials Research 361-363 (October 2011): 1859–62. http://dx.doi.org/10.4028/www.scientific.net/amr.361-363.1859.

Full text
Abstract:
According to the characteristics of silicon in water, analysis is implemented for the excess SiO2 content in a 300MW unit boiler water. Serious excess SiO2 content in the economizer inlet water and boiler water is caused by high-pressure heater leakage. In addition, SiO2 content increases with the raising feedwater temperature, because colloidal silicon solubility increases with the raising feedwater temperature. Colloidal silicon in water is induced by condenser tiny leakage. High-pressure heater plugging must be handled. Improving activated charcoal filters washing and boiler blow-off freque
APA, Harvard, Vancouver, ISO, and other styles
11

Herrmann, Nico, Harald S. Müller, Christoph Niklasch, Sylvie Michel-Ponnelle, and Benoît Masson. "The PACE-1450 Test Campaign - Leakage Behaviour of a Pre-Stressed Concrete Containment Wall Segment." Key Engineering Materials 711 (September 2016): 863–70. http://dx.doi.org/10.4028/www.scientific.net/kem.711.863.

Full text
Abstract:
Investigating nuclear power plant containments under accidental conditions obviously leads to the question of possible leakage through cracks of the pre-stressed concrete containment. In the last decades a number of civil engineering R&D programs dedicated to theoretical and experimental analyses have been performed. For the PACE-1450 experiment a leakage testing facility for pre-stressed curved specimen has been built in the laboratory of the Materials Testing and Research Institute (MPA Karlsruhe) at the Karlsruhe Institute of Technology (KIT). The test campaign has now been successfully
APA, Harvard, Vancouver, ISO, and other styles
12

Akram, Shazad, Johan Sidén, and Kent Bertilsson. "Battery Powered Inductive Welding System for Electrofusion Joints in Optical Fiber Microducts." Electronics 10, no. 6 (2021): 743. http://dx.doi.org/10.3390/electronics10060743.

Full text
Abstract:
Optical fiber microducts are joined together by mechanical joints. These mechanical joints are bulky, require more space per joint, and are prone to air pressure leakage and water seepage during service. A battery powered electrofusion welding system with a resistive-type joint has been recently developed to replace mechanical joints. These resistive-type electrofusion joints require physical connectors for power input. Due to a different installation environment, the power input connectors of resistive optical fiber microduct joints may corrode over time. This corrosion of connectors will eve
APA, Harvard, Vancouver, ISO, and other styles
13

Feng, Yan Ting, Xiang Feng Zheng, and Xue Xia Xu. "Failure Analysis on Tee Joint Crack of Subcritical Power Station Boiler Platen Superheater Header." Advanced Materials Research 538-541 (June 2012): 1992–97. http://dx.doi.org/10.4028/www.scientific.net/amr.538-541.1992.

Full text
Abstract:
Failure cause analysis was carried out on tee joint crack of boiler platen superheater header (12Cr1MoV) of subcritical power station applying microanalysis, mechanical properties test, chemical composition analysis, metallography examination and SEM observation etc. Results indicated that the tee joint crack originated at the original defects, connected with reheat cracks during propagation and led to leakage finally. The improper structure, the original welding defects, overhigh welding heat input, and excessive welding residual stress resulted in the leakage failure.
APA, Harvard, Vancouver, ISO, and other styles
14

Cerpa, F., D. Cáceres, C. Romero-Dapueto, et al. "Humidification on Ventilated Patients: Heated Humidifications or Heat and Moisture Exchangers?" Open Respiratory Medicine Journal 9, no. 1 (2015): 104–11. http://dx.doi.org/10.2174/1874306401509010104.

Full text
Abstract:
The normal physiology of conditioning of inspired gases is altered when the patient requires an artificial airway access and an invasive mechanical ventilation (IMV). The endotracheal tube (ETT) removes the natural mechanisms of filtration, humidification and warming of inspired air. Despite the noninvasive ventilation (NIMV) in the upper airways, humidification of inspired gas may not be optimal mainly due to the high flow that is being created by the leakage compensation, among other aspects. Any moisture and heating deficit is compensated by the large airways of the tracheobronchial tree, t
APA, Harvard, Vancouver, ISO, and other styles
15

Kadle, D. S., and E. M. Sparrow. "Numerical and Experimental Study of Turbulent Heat Transfer and Fluid Flow in Longitudinal Fin Arrays." Journal of Heat Transfer 108, no. 1 (1986): 16–23. http://dx.doi.org/10.1115/1.3246883.

Full text
Abstract:
Heat transfer from an array of parallel longitudinal fins to a turbulent air stream passing through the interfin spaces has been investigated both analytically/numerically and experimentally. The fins were integrally attached to a heated base plate, while the fin tips were shrouded to avoid leakage. In the analytical/numerical work, a conjugate problem was solved which encompassed turbulent flow and heat transfer in the air stream and heat conduction in the fins and in the base plate. The turbulence model and computational scheme were verified by comparison with experiment. It was found that t
APA, Harvard, Vancouver, ISO, and other styles
16

Diao, Chien Chen, Chia Ching Wu, Cheng Fu Yang, and Chao Chin Chan. "The Influence of Annealing Temperature on the Characteristics of 0.95 (Na0.5Bi0.5)TiO3-0.05 BaTiO3 Thin Films." Key Engineering Materials 434-435 (March 2010): 263–66. http://dx.doi.org/10.4028/www.scientific.net/kem.434-435.263.

Full text
Abstract:
In this study, 0.95 (Na0.5Bi0.5)TiO3-0.05 BaTiO3 + 1 wt% Bi2O3 (NBT-BT3) composition sintered at 1200oC for 2h is used as target to deposit the NBT-BT3 thin films. The excess 1wt% Bi2O3 is used to compensate the vaporization of Bi2O3 during the deposition process. Ferroelectric NBT-BT3 thin films are deposited on SiO2/Si and Pt/Ti/SiO2/Si substrates using RF magnetron sputter method using the ceramic target fabricated by ourselves. After depositing under the optimal parameters, the thin films are then heated by a conventional thermal annealing (CFA) process conducted in air at temperatures ran
APA, Harvard, Vancouver, ISO, and other styles
17

Abroshan, Hamid, and Mahdi Goodarzi. "Optimization of a three-layer rotary generator using genetic algorithm to minimize fuel consumption." Journal of Mechanical Engineering and Sciences 14, no. 1 (2020): 6304–21. http://dx.doi.org/10.15282/jmes.14.1.2020.09.0494.

Full text
Abstract:
Reduction of fuel consumption in power plants is an important issue due to their high rate of fuel usage. In the present article, this was done by optimizing rotary regenerator which have a great role in recovering thermal energy in power stations. Heat transfer and pressure drop through 13 popular flow passages of power plant's rotary regenerators were obtained by CFD simulations. The outcomes were used in a mathematical model of the rotary air heater by considering air leakages. The model was capable of distinguishing between different heating surfaces. Then it was used for optimizing a rege
APA, Harvard, Vancouver, ISO, and other styles
18

Nonga, Bernadette Ngo, Bonaventure Jemea, Angele O. Pondy, et al. "Unusual Life-Threatening Pneumothorax Complicating a Ruptured Complex Aspergilloma in an Immunocompetent Patient in Cameroon." Case Reports in Surgery 2018 (2018): 1–4. http://dx.doi.org/10.1155/2018/8648732.

Full text
Abstract:
An aspergilloma is a well-recognized lesion of the lung caused most of the time by the fungus Aspergillus fumigatus. Its main complication is hemoptysis and has been very rarely associated with tension pneumothorax. We present the case of a 47-year-old man with a history of treated and healed tuberculosis, which was successfully managed in our service for a ruptured right upper lobe complexed aspergilloma, complicated by a massive and tension pneumothorax. The patient underwent thoracotomy and lung resection with quick recovery. Conclusively, although rare, an aspergilloma may rupture and caus
APA, Harvard, Vancouver, ISO, and other styles
19

F. Abbas, Ammar, and Mahmood Z. Abdullah. "DESIGN AND IMPLEMENTATION OF A SMART HOME GAS DETECTION BASED ON MOBILE NETWORK SYSTEM." Journal of Engineering and Sustainable Development 25, no. 02 (2021): 9–16. http://dx.doi.org/10.31272/jeasd.25.2.2.

Full text
Abstract:
The rapid development of smart home and deep learning attract many types of research to meet the needs of the homeowner that make the right decisions based on preset settings or based on user behavior in the smart home. And because some gases cause air pollution, affect human health, cause lung cancer, breathing problems. and cause a fire as well. Many gases in our home can pose many dangers. One of the risks of using LPG is leakage in cylinders, gas installations, stoves, or LPG heaters. This paper focused on using technological development to alert about a gas leak inside the home to preserv
APA, Harvard, Vancouver, ISO, and other styles
20

Tzou, Wen Cheng, Chien Chen Diao, Chao Chin Chan, Chia Ching Wu, Chang Fu Yang, and Hung Chiuan Shiu. "The Influences of Annealing Temperatures on the Properties of the Sol-Gel Deposition SrBi4Ti4O15 Thin Films." Advanced Materials Research 415-417 (December 2011): 1855–58. http://dx.doi.org/10.4028/www.scientific.net/amr.415-417.1855.

Full text
Abstract:
In this study, SrBi4Ti4O15 (SBT) thin films were deposited onto the SiO2/p-Si(100) and Pt/Ti/SiO2/p-Si(100) substrates by using sol-gel method. After deposition, the SBT thin films were then heated by a rapid thermal annealing (RTA) process conducted in air for 1min at 600-800°C. The surface morphologies and the crystalline structures of the SBT thin films were investigated by using SEM and XRD patterns. The grain sizes increased and the pores decreased with rising RTA temperature. In addition, the coercive field decreased and the remanent polarization and saturation polarization increased wit
APA, Harvard, Vancouver, ISO, and other styles
21

Jin, Yong Fei, Jun Guo, and Ning Fang Yue. "Study on Overburden under Temperature Loading Coal Seam Outcrop Fire Area Heat Damage Mechanics Characteristics Experiment." Advanced Materials Research 1004-1005 (August 2014): 1198–203. http://dx.doi.org/10.4028/www.scientific.net/amr.1004-1005.1198.

Full text
Abstract:
Maglev uses MTS815.02 rock mechanics experimental electro-hydraulic systems and NM-4A nonmetallic ultrasonic testing analyzer for coal fire area overlying rock outcrop samples were heated fracture mechanics properties of experimental studies of rock samples reveal the strength and deformation characteristics with temperature the variation. The results showed that: rock microstructure changes at high temperatures on the mechanical properties have a significant effect, the higher the temperature, the greater the sandstone porosity, fissures, the more velocity is smaller; fire zone in the role of
APA, Harvard, Vancouver, ISO, and other styles
22

Panesar, Angad S., and Marco Bernagozzi. "Two-Phase Expander Approach for Next Generation of Heat Recovery Systems." International Journal of Renewable Energy Development 8, no. 3 (2019): 203–13. http://dx.doi.org/10.14710/ijred.8.3.203-213.

Full text
Abstract:
This study presents the numerical adaptations to the semi-empirical expander model in order to examine the feasibility of piston expanders under off-design and two-phase scenarios. This expander model considers supply valve pressure drop, condensation phenomena, heat losses, leakage losses and friction losses. Using Aspen HYSYS©, the expander model is utilised in simulating the next generation of integrated engine cooling and exhaust heat recovery system for future heavy-duty engines. The heat recovery system utilises water-propanol working fluid mixture and consists of independent high pressu
APA, Harvard, Vancouver, ISO, and other styles
23

Abed, Akram H., Sergey E. Shcheklein, and Valery M. Pakhaluev. "Heat transfer intensification in emergency cooling heat exchanger and dry cooling towers on nuclear power plant using air-water mist flow." Nuclear Energy and Technology 5, no. 4 (2019): 281–87. http://dx.doi.org/10.3897/nucet.5.47972.

Full text
Abstract:
Advanced nuclear power plants are equipped with passive emergency heat removal systems (PEHRS) for removing the decay heat from reactor equipment in accidents accompanied by primary circuit leakage to the final heat absorber (ambient air). Herein, the intensity of heat dissipation to air from the outer surface of the heat exchanger achieved by buoyancy induced natural convection is extremely low, which need to a large heat exchanger surface area, apply different types of heat transfer intensification including (grooves, ribs and extended surfaces, positioning at higher altitudes, etc.). The in
APA, Harvard, Vancouver, ISO, and other styles
24

Fitrullah, Muhammad, Marta Hendra, A. A. Alhamidi, et al. "The Improvement of Product Quality and Production Capacity of Metal Coin Dies by Tempering Treatment and PVD TiN Coating in IsodurTM Steel." Advanced Materials Research 1112 (July 2015): 323–28. http://dx.doi.org/10.4028/www.scientific.net/amr.1112.323.

Full text
Abstract:
In industry of coins production, dies is proportionally compared with the production of coin. Dies, one of the essential components, is externally influenced by geometry, relief, setting parameter production and others. While, internally dies will be affected by its physical property and surface treatment. Phenomenon of dimension deformation and poor wear resistance on dies surface, are part of leakage factor in coin production. In this research, the mechanical properties of IsodurTM steel is being controlled by heat treatment especially tempering treatment and TiN PVD coating with arc cathodi
APA, Harvard, Vancouver, ISO, and other styles
25

Prastyo, Elli, and Syamsul Ma'arif. "WATER LEAKED ANALYSIS IN THE GAS AIR HEATER IN PT CIREBON POWER SERVICE." Journal of Green Science and Technology 4, no. 3 (2020). http://dx.doi.org/10.33603/jgst.v4i3.3997.

Full text
Abstract:
PT. Cirebon Power Services is the first steam power plant (PLTU) in Indonesia that uses Supercritical Boiler technology. Combustion in a boiler using coal fuel produces hot gas which must be disposed of by utilizing a vacuum from the ID Fan and releasing it into the atmosphere. Gas Air Heater is a device that utilizes convection heat transfer from boiler exhaust heat to heat Primary Air and Secondary Air. The analysis was carried out by comparing the Gas Air Heater A and B through three parameters namely Air Leakage, X Ratio, and Efficiency. Data was collected from 31 December 2019 to 30 Janua
APA, Harvard, Vancouver, ISO, and other styles
26

Kaya, Durmus, and Muharrem Eyidogan. "Energy Conservation Opportunity in Boiler Systems." Journal of Energy Resources Technology 131, no. 3 (2009). http://dx.doi.org/10.1115/1.3185440.

Full text
Abstract:
In this study, “energy efficiency” study has been performed for a natural gas fuelled boiler, operating at 42,000 kPa pressure and 713.15 K temperature, with a nominal capacity of 33.33 kg/s steam. Within this frame, temperature, pressure, velocity, and gas analysis measurements have been made, and energy, mass balances, and exergy analysis have been formed. Then, the efficiency of boiler, potential energy saving options and savings quantities, investment costs, and payback period for normal operating conditions have been calculated from the energy and mass balances. Implementation cost is req
APA, Harvard, Vancouver, ISO, and other styles
27

Hajebzadeh, Hamed, and Abdulhamid NM Ansari. "Modification of rotary air preheater toward achieving extended life-span utilizing porous media approach: A case study." Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy, July 22, 2021, 095765092110349. http://dx.doi.org/10.1177/09576509211034977.

Full text
Abstract:
The main goal of this study is to achieve the extended operating life of the rotary regenerative air pre-heater (Ljungström) of Bandar Abbas power plant by modifying operational parameters by decreasing the corrosion. To achieve this goal, a three-dimensional CFD simulation of the Ljungström is carried out, utilizing the thermal non-equilibrium porous media model. Temperatures are validated against measured data from the power plant with a maximum relative error of 5.54% on the Celsius scale, and mass flow rates are validated with a maximum relative error of −5.25%. The effect of the Ljungströ
APA, Harvard, Vancouver, ISO, and other styles
28

Khamdila, Ali, Santhi Wilastari, and Agus Saleh. "MENJAGA KESTABILAN SUHU RUANG EVAPORATOR BERDAMPAK PADA HASIL PRODUKSI AIR TAWAR FRESH WATER GENERATOR." JURNAL SAINS DAN TEKNOLOGI MARITIM 19, no. 2 (2019). http://dx.doi.org/10.33556/jstm.v19i2.200.

Full text
Abstract:
<p><em>Maintaining a Fresh Water Generator from the loss of vacuuming means getting the best fresh water production process. The balance of the heated substance and the heater measurement inside the evaporator could effect on the steam result or even could influence the steam process. There are many factors that could cause the loss or the decreasing of vacuuming when operating Fresh Water Generator, such as system leakage, the lack of sea water volume used for vacuuming, the balance of water ejector capability to maintain the steam volume inside Fresh Water Generator, the brine ej
APA, Harvard, Vancouver, ISO, and other styles
29

McQueen, Noah, Michael J. Desmond, Robert H. Socolow, Peter Psarras, and Jennifer Wilcox. "Natural Gas vs. Electricity for Solvent-Based Direct Air Capture." Frontiers in Climate 2 (January 27, 2021). http://dx.doi.org/10.3389/fclim.2020.618644.

Full text
Abstract:
Removing CO2from the air with chemicals (Direct Air Capture, DAC) requires a significant amount of energy. Here, we evaluate the cost of co-constructing a solvent DAC process with its energy system. We compare eight energy systems paired with two alternative designs for a liquid-solvent DAC system capturing 1 MtCO2/year, which requires roughly 240 to 300 megawatts of steady power equivalent, 80% thermal and 20% electric. Two energy systems burn natural gas onsite for heat and electricity, capturing nearly all the CO2released during combustion, and six are all-electric non-fossil systems. The c
APA, Harvard, Vancouver, ISO, and other styles
30

Tilbury, Farida. "Filth, Incontinence and Border Protection." M/C Journal 9, no. 5 (2006). http://dx.doi.org/10.5204/mcj.2666.

Full text
Abstract:

 
 
 This paper investigates linkages between two apparently disparate government initiatives. Together they function symbolically to maintain Australia’s moral order by excluding filth, keeping personal and national boundaries tight and borders secure. The Commonwealth government recently set aside over five million dollars to improve continence in the Australian population (incontinence is the inability to control movements of the bowel or bladder, producing leakage of filth in the form of urine and faeces). The Strategy funded research into prevalence rates, treatment strate
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!