Academic literature on the topic 'And over Animals Bone Plates Dogs Fracture Fixation'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'And over Animals Bone Plates Dogs Fracture Fixation.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "And over Animals Bone Plates Dogs Fracture Fixation"

1

Hurter, K., P. Schawalder, and H. G. Schmökel. "Percutaneous plating of tibial fractures in two dogs." Veterinary and Comparative Orthopaedics and Traumatology 16, no. 03 (2003): 191–95. http://dx.doi.org/10.1055/s-0038-1632776.

Full text
Abstract:
SummaryA trend toward minimally invasive procedures in the treatment of fractures in human patients is apparent in recent publications. Percutaneous plating is one method of fracture fixation, conceived to minimise soft tissue damage and preserve soft tissue and bone vascularity. The use of fewer screws, in longer bridging plates, is also a relatively new technique in the stabilisation of comminuted diaphyseal fractures in human patients. A combination of these techniques was applied in two dogs with comminuted tibial fractures.The plates were passed subfascially and the screws inserted throug
APA, Harvard, Vancouver, ISO, and other styles
2

Lanz, O., R. McLaughlin, S. Elder, S. Werre, and D. Filipowicz. "A biomechanical comparison of 3.5 locking compression plate fixation to 3.5 limited contact dynamic compression plate fixation in a canine cadaveric distal humeral metaphyseal gap model." Veterinary and Comparative Orthopaedics and Traumatology 22, no. 04 (2009): 1–8. http://dx.doi.org/10.3415/vcot-08-05-0042.

Full text
Abstract:
Summary3.5 locking compression plate (LCP) fixation was compared to 3.5 limited contact dynamic compression plate (LC-DCP) fixation in a canine cadaveric, distal humeral metaphyseal gap model. Thirty paired humeri from adult, large breed dogs were separated into equal groups based on testing: static compression, cyclic compression, and cyclic torsion. Humeral constructs stabilized with LCP were significantly stiffer than those plated with LCDCP when loaded in static axial compression (P = 0.0004). When cyclically loaded in axial compression, the LCP constructs were significantly less stiff tha
APA, Harvard, Vancouver, ISO, and other styles
3

Kull, M. A., M. Haessig, P. M. Montavon, and K. Voss. "Repair of long-bone fractures in cats and small dogs with the Unilock mandible locking plate system." Veterinary and Comparative Orthopaedics and Traumatology 22, no. 05 (2009): 398–405. http://dx.doi.org/10.3415/vcot-08-09-0084.

Full text
Abstract:
Summary Objectives: To retrospectively evaluate stabilisation of long-bone fractures in cats and small dogs using the Unilock system. Methods: Medical histories and radiographs of consecutive patients with long-bone fractures stabilised with the Unilock system were reviewed. Cases with follow-up radiographs taken at least four weeks postoperatively were included. Signalment of the patient, fracture localisation and type, primary fracture repair or revision surgery, single or double plating, and complications for each patient were noted. Additionally, implant size, number of screws, number of c
APA, Harvard, Vancouver, ISO, and other styles
4

Menghini, Timothy L., Georgia Shriwise, and Peter Muir. "Fracture Healing in 37 Dogs and Cats with Implant Failure after Surgery (2013–2018)." Animals 13, no. 9 (2023): 1549. http://dx.doi.org/10.3390/ani13091549.

Full text
Abstract:
Implant failure is common in small animal orthopedics, but risk factors are rarely reported. Our objective was to determine whether abnormal fracture healing was associated with implant failure after fracture fixation in dogs and cats in a consecutive series of cases. Thirty-seven client-owned animals (thirty-two dogs, five cats) diagnosed with implant failure after fracture treatment from January 2013–September 2018 were studied. Medical and radiographic records were retrospectively reviewed to identify patients that underwent fracture fixation using open reduction and internal fixation with
APA, Harvard, Vancouver, ISO, and other styles
5

Muir, P., and K. A. Johnson. "Fractures of the Proximal Ulna in Dogs." Veterinary and Comparative Orthopaedics and Traumatology 09, no. 02 (1996): 88–94. http://dx.doi.org/10.1055/s-0038-1632509.

Full text
Abstract:
SummaryIn a retrospective study of fractures of the proximal ulna in dogs, 22 cases were identified over a 12-year period. Follow-up data was available for 13 dogs. Fractures of the proximal ulna were often comminuted, and most commonly had an intra-articular component affecting the ulnaro-humeral joint. Common causes included: motor vehicle trauma and falls from a height. Blunt thoracic trauma and additional orthopaedic injuries were often seen with the more severe types of fractures.Healing of intra-articular proximal ulnar fractures usually occurred after anatomical reconstruction and rigid
APA, Harvard, Vancouver, ISO, and other styles
6

Abhijit, Nikam, P. Mandade Ramprasad, and V. More Govind. "Clinical Outcomes of Locking Compression Plating Technique in Long Fracture of Dog with or without Osteoinducer by using Ct Scan: 12 Cases." Clinical Outcomes of Locking Compression Plating Technique in Long Fracture of Dog with or without Osteoinducer by using Ct Scan: 12 Cases 8, no. 12 (2023): 20. https://doi.org/10.5281/zenodo.10376122.

Full text
Abstract:
The research was carried out on twelve canines that presented with long fractures at Veterinary clinical complex, Nagpur veterinary college, Nagpur. The fracture was identified pre-operatively with orthopaedic and radiographic examinations. Fracture stabilization using the method of open reduction and internal fixation was used in all twelve canines. This procedure included the utilization of 3.5mm locking compression plates. Preoperative planning was carried out using demographic data in conjunction with clinical and radiological examination. Using locking plates in a locking way, a stable fi
APA, Harvard, Vancouver, ISO, and other styles
7

Dučić, Risto, Bogomir Bolka Prokić, Milan Hadži-Milić, et al. "Correlation of Bone Strength in an Animal Model (Rabbit) After Fracture and During the Period of Fixation with a Titanium Micro Plate." Acta Veterinaria 72, no. 4 (2022): 442–52. http://dx.doi.org/10.2478/acve-2022-0036.

Full text
Abstract:
Abstract The period of bone healing after trauma goes through certain physiological processes. In situations where a bone fracture occurs, our intention is to surgically position in an appropriate morpho-anatomical position. For osteosynthesis we used vipla wire and micro plates with corresponding screws. The aim of our research was to evaluate the optimal time for the removal of the osteosynthetic material, fracture site biomechanical stability, and measurement of the callus thickness. For this research ten 4 months old rabbits with right leg femur fracture were used. Osteosynthesis was done
APA, Harvard, Vancouver, ISO, and other styles
8

Bruecker, K. A., J. L. Palmer, Barbara Powers, M. B. Histand, and P. D. Schwarz. "A Mechanical and Histological Comparison of Bone Healing Using Titanium Bone Plates with Porous Surfaced Titanium Screws versus Smooth Surfaced Titanium Screws." Veterinary and Comparative Orthopaedics and Traumatology 4, no. 01 (1991): 1–10. http://dx.doi.org/10.1055/s-0038-1633242.

Full text
Abstract:
SummaryBilateral midshaft femoral osteotomies were stabilized with a 3 mm fracture gap in 12 dogs using titanium bone plates and either smooth surfaced (SS) or porous surfaced (PS) titanium screws. Mechanical studies demonstrated that PS screws required a significantly greater torque to remove than the SS screws at both 8 and 16 weeks. At 16 weeks, screw removal torque increased by a factor of 1.3 over the insertion torque for PS screws and decreased by a factor of 2.9 for SS screws. Histologically, the amount of new bone formation and porosity, over the entire length of the femur, was signifi
APA, Harvard, Vancouver, ISO, and other styles
9

Foutz, T. L., W. G. Keller, J. Brown, and D. N. Aron. "Experimental and Clinical Experience with an IM Pin External Skeletal Fixator Tie-in Configuration." Veterinary and Comparative Orthopaedics and Traumatology 4, no. 03 (1991): 86–94. http://dx.doi.org/10.1055/s-0038-1633259.

Full text
Abstract:
SummaryAn intramedullary (IM) pin external skeletal fixator “tie-in” configuration is described, for use as a stabilizing device, in the treatment of fractures of the humerus and femur in the dog and cat. With in vitro testing of the configuration using cadaver bones, more resistance to bending was gained by the tie-in arrangement than was possible with one not tied-in. Forty-one clinical cases documented the use of the tie-in configuration for fracture repair. Twenty-four dogs and 17 cats were treated over the past seven years. Fourteen were used to stabilize fractures of the humerus and 27 f
APA, Harvard, Vancouver, ISO, and other styles
10

Ngeow, W.C., and C.B. Lian. "Unilateral comminuted and complicated fracture of the mandible due to dog attack." July 1, 1996. https://doi.org/10.5281/zenodo.811498.

Full text
Abstract:
Fractures of the mandible and their management are discussed in detail in textbooks and articles dealing with facial trauma. This paper presents the management and treatment of a case of a unilateral comminuted and complicated fracture of the mandible due to dog attack on a geriatric patient. The attack also severed the patient's right arm. Due to the severity of the trauma, an emergency surgery was performed on the mandible and arm. This record was migrated from the OpenDepot repository service in June, 2017 before shutting down.
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!