1

Marchewka, M., and J. Zubrzycki. "Construction aspects of intraocular artificial lenses." Journal of Physics: Conference Series 2412, no. 1 (December 1, 2022): 012011. http://dx.doi.org/10.1088/1742-6596/2412/1/012011.

Full text
Abstract:
Abstract A cataract is a disease of the 21st century. In highly developed countries, the opacification of the intraocular lens is removed and replaced with an implant. This article discusses the essential aspects related to the construction of implants that imitate the natural lens of the eyeball. The research was carried out owing to X-ray microtomography. Observer design differences in the two lenses' structures contribute to the implant's quality in question. The study aimed to check and compare two types of implants in terms of the design and manufacturing quality of the given lenses. The
APA, Harvard, Vancouver, ISO, and other styles
2

Kondyurina, Irina, and Alexey Kondyurin. "Foreign Body Reaction (Immune Response) for Artificial Implants Can Be Avoided: An Example of Polyurethane in Mice for 1 Week." Journal of Functional Biomaterials 14, no. 8 (August 17, 2023): 432. http://dx.doi.org/10.3390/jfb14080432.

Full text
Abstract:
Despite great success with artificial implants for the human body, modern implants cannot solve major health problems. The reason is an immune reaction of organisms to artificial implants, known as the foreign body reaction. We have found a way to avoid or decrease the foreign body reaction. The surface of an artificial implant is modified with condensed aromatic structures containing free radicals, which provide a covalent attachment of host proteins in a native conformation. The total protein coverage prevents the direct contact of immune cells with the implant surface, and the immune cells
APA, Harvard, Vancouver, ISO, and other styles
3

Bowers, Christian A., Jaron H. McMullin, Cameron Brimley, Linsey Etherington, Faizi A. Siddiqi, and Jay Riva-Cambrin. "Minimizing bone gaps when using custom pediatric cranial implants is associated with implant success." Journal of Neurosurgery: Pediatrics 16, no. 4 (October 2015): 439–44. http://dx.doi.org/10.3171/2015.2.peds14536.

Full text
Abstract:
OBJECT Occasionally after a craniotomy, the bone flap is discarded (as in the case of osteomyelitis) or is resorbed (especially after trauma), and an artificial implant must be inserted in a delayed fashion. Polyetheretherketone (PEEK) implants and hard-tissue replacement patient-matched implants (HTR-PMI) are both commonly used in such cases. This study sought to compare the failure rate of these 2 implants and identify risk factors of artificial implant failure in pediatric patients. METHODS This was a retrospective cohort study examining all pediatric patients who received PEEK or HTR-PMI c
APA, Harvard, Vancouver, ISO, and other styles
4

Lambert, Lorraine. "Artificial Hair Implants." International Society of Hair Restoration Surgery 6, no. 5 (September 1996): 9.2–9. http://dx.doi.org/10.33589/6.5.9b.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Inoue, Takashi. "The development of an artificial protein for periodontal application." Impact 2018, no. 3 (June 15, 2018): 79–81. http://dx.doi.org/10.21820/23987073.2018.3.79.

Full text
Abstract:
Most artificial implants in medicine are purely mechanical. They do not harness the natural biology, merely co-exist alongside it. This is no different in dentistry where false teeth tend not to interact with the biology of the mouth. Inoue and his team are developing bio-hybrid dental implants that are capable integrating themselves into the jawbone. The new implant will be more stable and long-lasting as well as being able to replicate the function and feel of natural teeth. They also have the crucial ability of being able to adapt to the restructuring in the jawbone that occurs as children
APA, Harvard, Vancouver, ISO, and other styles
6

Mohammadi, Bijan, Zahra Abdoli, and Ehsan Anbarzadeh. "Investigation of the Effect of Abutment Angle Tolerance on the Stress Created in the Fixture and Screw in Dental Implants Using Finite Element Analysis." Journal of Biomimetics, Biomaterials and Biomedical Engineering 51 (June 14, 2021): 63–76. http://dx.doi.org/10.4028/www.scientific.net/jbbbe.51.63.

Full text
Abstract:
Today, an artificial tooth root called a dental implant is used to replace lost tooth function. Treatment with dental implants is considered an effective and safe method. However, in some cases, the use of dental implants had some failures. The success of dental implants is influenced by several biomechanical factors such as loading type, used material properties, shape and geometry of implants, quality and quantity of bone around implants, surgical method, lack of rapid and proper implant surface's integration with the jaw bone, etc. The main purpose of functional design is to investigate and
APA, Harvard, Vancouver, ISO, and other styles
7

Earar, Kamel, Ioan Sirbu, Ctristian Onisor, and Elena Luca. "Oral Rehabilitation on Implants and Introduction of Pathogenic Mechanisms in Relation to Oral Implants - Sugar Diabetes." Revista de Chimie 70, no. 10 (November 15, 2019): 3750–52. http://dx.doi.org/10.37358/rc.19.10.7639.

Full text
Abstract:
Dental implants are made of medical titanium and perfectly fit into human bone tissue; the dental implant can last a lifetime. Not beeing living organic structures, there are no nerve endings, neither at the implant level nor at the artificial crown level. The use of quality implants by an experienced implantologist, assisted by advanced technology, transforms the treatment with dental implants into the medical-surgical act with the highest success rate among dental and even medical treatments.Through the complete replacement of the tooth, including the root, can artificially reproduce the fun
APA, Harvard, Vancouver, ISO, and other styles
8

Bhari, Anju, Neelam Pushker, Sahil Agrawal, Mandeep S. Bajaj, and Seema Kashyap. "Outcome of porous polyethylene implants in anophthalmic sockets with implant migration." Kerala Journal of Ophthalmology 36, no. 1 (January 2024): 30–34. http://dx.doi.org/10.4103/kjo.kjo_28_22.

Full text
Abstract:
Purpose: To evaluate the surgical outcome of porous polyethylene orbital implants in anophthalmic sockets with implant migration. Methods: A prospective interventional case series: Patients of anophthalmic sockets with implant migration were recruited, which were replaced with porous polyethylene implants. Patients were evaluated for recurrence of implant migration, ability to wear artificial eye, movement of prosthesis, complications, and satisfaction. Results: Fifteen patients with a mean age of 8.33 years were operated for implant migration. Postoperatively, recurrence of implant migration
APA, Harvard, Vancouver, ISO, and other styles
9

Romanos, Georgios E., Gerard A. Fischer, Zaid T. Rahman, and Rafael Delgado-Ruiz. "Spectrometric Analysis of the Wear from Metallic and Ceramic Dental Implants following Insertion: An In Vitro Study." Materials 15, no. 3 (February 4, 2022): 1200. http://dx.doi.org/10.3390/ma15031200.

Full text
Abstract:
Titanium wear is a growing area of interest within dental implantology. This study aimed to investigate titanium and zirconium wear from dental implants at the time of insertion using X-ray-fluorescence spectrometry (XRF) and an in vitro protocol utilizing artificial bovine bone plates. Five groups were analyzed using XRF-spectrometry: groups 1–4 (titanium implants) and group 5 (zirconia implants). The implants were inserted into two bone blocks held together by a vice. The blocks were separated, and the insertion sites were analyzed for titanium (Ti) and zirconium (Zr). Statistical descriptiv
APA, Harvard, Vancouver, ISO, and other styles
10

Walter, Peter. "Implants for artificial vision." Expert Review of Ophthalmology 4, no. 5 (October 2009): 515–23. http://dx.doi.org/10.1586/eop.09.42.

Full text
APA, Harvard, Vancouver, ISO, and other styles
11

Parshin, Yuriy, Maksim Mishnev, Vladimir Trezubov, and Roman Rozov. "RATIONALE FOR THE USE OF DORZALLY TILTED DISTAL ARTIFICIAL SUPPORTS FOR EXTENDED IMPLANT PROSTHESES IN ELDERLY PATIENTS." Actual problems in dentistry 19, no. 3 (November 30, 2023): 119–25. http://dx.doi.org/10.18481/2077-7566-2023-19-3-119-125.

Full text
Abstract:
The subject of the research is implant prosthetics.
 The goal is to increase the efficiency of implant prosthetics by optimizing the design of the prosthesis.
 Methodology. 131 patients (57 men and 74 women) aged from 60 to 82 years (mean age 68.3 ± 7.3 years) were examined.
 The patients were divided into 3 groups: group 1 – 36 patients (14 men and 22 women with an average age of 70.1 ± 5.4 years) with vertical distal implants without dorsal weight; group 2 – 44 people (19 men, 25 women with an average age of 69.4 ± 7.2 years) with inclined distal implants without dorsal weight
APA, Harvard, Vancouver, ISO, and other styles
12

Casesnoves, Francisco. "Nonlinear Comparative Optimization for Biomaterials Wear in Artificial Implant Technology." Key Engineering Materials 800 (April 2019): 52–59. http://dx.doi.org/10.4028/www.scientific.net/kem.800.52.

Full text
Abstract:
Today, artificial implants (AI) industry depends strongly on tribological constitution of the material (s) of the implant. Erosion, corrosion, tribocorrosion and biocorrosion are essential factors to determine both functionality and lifetime of the AIs. Histo-Biocompatibility is also an additional constraint, indispensable for implant manufacturing process. The prediction of durability, based on the computational and experimental study of constituents of AI material (s) are key factors to obtain objective data of any AI characteristics. This contribution deals with a computational comparative
APA, Harvard, Vancouver, ISO, and other styles
13

Roman, Călin Rareş, and Lidia Adriana Sorcoi. "Preliminary Studies Regarding the Behaviour of New Titanium Implants." Materials Science Forum 672 (January 2011): 233–36. http://dx.doi.org/10.4028/www.scientific.net/msf.672.233.

Full text
Abstract:
This paper presents a study concerning a new titanium-based product reached by the specific techniques of powder metallurgy. The product was tested in vitro to corrosion in artificial saliva and in vivo by biological inocuity on sheep and rats for biocompatibility. The chemical composition of artificial saliva solutions used for general corrosion tests were: Fusayama solution; Carter solution; Ericsson solution; Hank solution; Ringer solution. The exposure length was 48, 720, 1440 and 2784 hours. On the sheep, six titanium implants of purity 99.89%, sintered with microporosities and nanoporosi
APA, Harvard, Vancouver, ISO, and other styles
14

Ibrahim, Ahmad, Marius Heitzer, Anna Bock, Florian Peters, Stephan Christian Möhlhenrich, Frank Hölzle, Ali Modabber, and Kristian Kniha. "Relationship between Implant Geometry and Primary Stability in Different Bony Defects and Variant Bone Densities: An In Vitro Study." Materials 13, no. 19 (September 30, 2020): 4349. http://dx.doi.org/10.3390/ma13194349.

Full text
Abstract:
Aim: This in vitro study aimed to evaluate the effects of implant designs on primary stability in different bone densities and bony defects. Methods: Five implant types (tapered-tissue-level, tissue-level, zirconia-tissue-level, bone-level, and BLX implants) were used in this assessment. The implants were inserted into four different artificial bone blocks representing varying bone-density groups: D1, D2, D3, and D4. Aside from the control group, three different types of defects were prepared. Using resonance frequency analysis and torque-in and -out values, the primary stability of each impla
APA, Harvard, Vancouver, ISO, and other styles
15

Fortunato, P., M. Schettini, and M. Gallucci. "Risk factors for urological prosthetic infection." Urologia Journal 64, no. 1 (February 1997): 65–69. http://dx.doi.org/10.1177/039156039706400115.

Full text
Abstract:
We reviewed our experience of 91 procedures for implant and revision of urological prostheses from 1989 to 1996. The aim of the study was to determine the risk factors for urological prostheses. The procedures consisted of 48 implants of artificial urinary sphincters AMS 800 (35 primary implants and 13 revisions) and 43 penile prostheses (40 primary implants and 3 revisions). Simultaneous penile reconstruction was performed in 5 cases. The mean follow-up was 2 years (range 1-6 years) for artificial urinary sphincter and 1.8 years (range 1-4) for penile prostheses. Infection occurred in 7 cases
APA, Harvard, Vancouver, ISO, and other styles
16

Jeu, Samuel, Etienne Guillaud, Laurent Hauret, Jean-Christophe Coutant, and Bruno Ella. "Assessment of the Correlation between the Implant Distance and Primary Stability by Resonance Frequency Analysis." Journal of Dental Surgery 2015 (June 10, 2015): 1–7. http://dx.doi.org/10.1155/2015/568715.

Full text
Abstract:
Objective. The aim of this study was to assess the influence of the interimplant distance on the implant primary stability (ISQ) by Resonance Frequency Analysis (RFA). Method. Forty-five implants were placed in the mandible of human cadavers and 108 in artificial bone substrates in the form of polyurethane foam blocks. Primary implant stability was successively measured first by RFA immediately after the placement of the first implant (A) and then after two other implants (B and C) proximal and distal to the first implant. The interimplant distances were defined from 1 to 6 mm and the three pr
APA, Harvard, Vancouver, ISO, and other styles
17

Yuk, Ju Chan, Kyoung Hyup Nam, and Suk Hee Park. "Additive-manufactured synthetic bone model with biomimicking tunable mechanical properties for evaluation of medical implants." International Journal of Bioprinting 10, no. 1 (January 10, 2024): 1067. http://dx.doi.org/10.36922/ijb.1067.

Full text
Abstract:
Additive manufacturing has enabled the customization of biomedical systems, including transplantable medical devices, to achieve mechanical biocompatibility. For bone implants, patient-specific bone models must be used to evaluate the mechanical properties of implant compression and subsidence. This study proposes a methodology for designing and fabricating bone models to evaluate patient-specific bone implants. The method involves three-dimensional printing of infill-varied structure, with alternating high-low-high infill density regions, which undergo sequential deformation from the surficia
APA, Harvard, Vancouver, ISO, and other styles
18

Lee, Sang-Hee, Kyu-Seok Kim, Hye-Young Mun, and Jung-Yun Kang. "Prediction model for dental implants utilization in the elderly after the national health insurance coverage of dental implants : focusing on socioeconomic factors." Journal of Korean Society of Dental Hygiene 24, no. 1 (February 28, 2024): 9–16. http://dx.doi.org/10.13065/jksdh.20240002.

Full text
Abstract:
Objectives: The demand for dental care is expected to increase as the population ages. This study aimed to predict the utilization of dental implant care following the expansion of national health insurance benefits for dental implants. Methods: Multiple linear regression analysis was performed on HIRA big data open portal data and DNN-based artificial intelligence models to forecast the utilization of dental care in relation to the national health insurance coverage for dental implants. Results: National health insurance coverage of dental implants was found to be associated with the number o
APA, Harvard, Vancouver, ISO, and other styles
19

Cardoso, Mario J., and Michael K. Rosner. "Multilevel cervical arthroplasty with artificial disc replacement." Neurosurgical Focus 28, no. 5 (May 2010): E19. http://dx.doi.org/10.3171/2010.1.focus1031.

Full text
Abstract:
Object In this study, the authors review the technique for inserting the Prestige ST in a contiguous multilevel cervical disc arthroplasty in patients with radiculopathy and myelopathy. They describe the preoperative planning, surgical technique, and their experience with 10 patients receiving a contiguous Prestige ST implant. They present contiguous multilevel cervical arthroplasty as an alternative to multilevel arthrodesis. Methods After institutional board review approval was obtained, the authors performed a retrospective review of all contiguous multilevel cervical disc arthroplasties wi
APA, Harvard, Vancouver, ISO, and other styles
20

Fanali, Stefano, Margherita Tumedei, Pamela Pignatelli, Alessandra Lucchese, Francesco Inchingolo, Adriano Piattelli, and Giovanna Iezzi. "Comparative In Vitro Evaluation of the Primary Stability in D3 Synthetic Bone of Two Different Shapes and Pitches of the Implant Threads." Applied Sciences 11, no. 12 (June 17, 2021): 5612. http://dx.doi.org/10.3390/app11125612.

Full text
Abstract:
Background: Implant primary stability can be affected by several factors related to implant macrogeometry, local anatomy, and surgical techniques. The aim of this research was to study primary stability on polyurethane foam sheets of wide-threaded implant design compared to narrow-threaded implants. Materials and methods: Two different implant designs were positioned on D3 density polyurethane blocks in a standardized environment: the wide-threaded implant and the narrow-threaded implant, for a total of 160 specimens. Moreover, for each group, two different sizes were considered: 3.8mm × 12mm
APA, Harvard, Vancouver, ISO, and other styles
21

Roumeliotis, George. "Bionic man: Principles and limits." Ηθική. Περιοδικό φιλοσοφίας, no. 13 (January 28, 2021): 56. http://dx.doi.org/10.12681/ethiki.25985.

Full text
Abstract:
The subject of this paper is the ethical considerations raised in the issue of “bionic man”, a man whose many organs have been replaced by artificial, and the principles and ethical limitations that are inherent in this process. Four basic bioethical principles are acknowledged in the international bibliography: a) the principle of beneficence; b) the principle of autonomy and informed consentof patients; c) the principle of justice; d) the principle of equality. Apart from this,some more issues should be taken into consideration in the discussion about theethics of artificial implants: the al
APA, Harvard, Vancouver, ISO, and other styles
22

Wang, X. G., Jie Mo Tian, Chuan Zeng Zhang, Zhi Ping Guo, Li Min Dong, and Chang An Wang. "Study of Animal Bio-Ceramic Implants with 3D High Resolution CT." Key Engineering Materials 280-283 (February 2007): 1629–30. http://dx.doi.org/10.4028/www.scientific.net/kem.280-283.1629.

Full text
Abstract:
Animal implants experiments are obligatory when developing human artificial hard tissues, such as bio-ceramics. Optical microscope is often used to inspect implant slices but may destroy original status when slicing up. We tried 3D high resolution CT to nondestructively study biocompatibility and degradation of bio-ceramics implants. 3D CT provides 3D structure information. Typical pixel size of 3D high resolution CT is 50 microns. Generally, implants differs with tissues in density and structure, on basis of which we can identify details with CT slice. Experiments of bio-ceramic implanted int
APA, Harvard, Vancouver, ISO, and other styles
23

Kumar, Priyadarshi Biplab, and Dayal R. Parhi. "Vibrational characterization of a human femur bone and its significance in the designing of artificial implants." World Journal of Engineering 14, no. 3 (June 12, 2017): 222–26. http://dx.doi.org/10.1108/wje-07-2016-0033.

Full text
Abstract:
Purpose Being an interdisciplinary research area, biomechanics has gained interest among researchers. Biomechanics deals with integration of mechanical phenomenon with the structural and functional aspects of biological systems. Biological systems being very much complex provide a very intricate platform for their analysis. In case of damages created by accidents or sport malfunctions, artificial implants are used for the replacement of bones. These implants may cause incompatibility with the human body, depending on their design and characterization. So, this research aims to analyze the vibr
APA, Harvard, Vancouver, ISO, and other styles
24

Lung, Hsuan, Jui-Ting Hsu, Aaron Yu-Jen Wu, and Heng-Li Huang. "Biomechanical Effects of Diameters of Implant Body and Implant Platform in Bone Strain around an Immediately Loaded Dental Implant with Platform Switching Concept." Applied Sciences 9, no. 10 (May 16, 2019): 1998. http://dx.doi.org/10.3390/app9101998.

Full text
Abstract:
Dental implants designed with platform switching have been used clinically to reduce crestal bone resorption. The aim of this study was to determine the biomechanical effects of loading types, diameter of platform, and implant diameter in bone strain around immediately loaded implants with platform switching concept. Platform-switching features of dental implants with various diameters of implant body and implant platform (named as RP5.0, RP4.3, and NP3.5) were inserted into artificial bone blocks. The initial implant stability was confirmed using a Periotest device before the loading test. Ro
APA, Harvard, Vancouver, ISO, and other styles
25

Kohal, Ralf J., Ellen Riesterer, Kirstin Vach, Sebastian B. M. Patzelt, Aljaž Iveković, Lara Einfalt, Andraž Kocjan, and Anna-Lena Hillebrecht. "Fracture Resistance of a Bone-Level Two-Piece Zirconia Oral Implant System—The Influence of Artificial Loading and Hydrothermal Aging." Journal of Functional Biomaterials 15, no. 5 (May 7, 2024): 122. http://dx.doi.org/10.3390/jfb15050122.

Full text
Abstract:
Preclinical and clinical research on two-piece zirconia implants are warranted. Therefore, we evaluated the in vitro fracture resistance of such a zirconia oral implant system. The present study comprised 32 two-piece zirconia implants and abutments attached to the implants using a titanium (n = 16) or a zirconia abutment screw (n = 16). Both groups were subdivided (n = 8): group T-0 comprised implants with a titanium abutment screw and no artificial loading; group T-HL was the titanium screw group exposed to hydro-thermomechanical loading in a chewing simulator; group Z-0 was the zirconia abu
APA, Harvard, Vancouver, ISO, and other styles
26

Cohen, Omer, Ofer Moses, Talia Gurevich, Roni Kolerman, Alina Becker, and Zeev Ormianer. "The Effect of Undersized Drilling on the Coronal Surface Roughness of Microthreaded Implants: An In Vitro Study." Applied Sciences 10, no. 15 (July 29, 2020): 5231. http://dx.doi.org/10.3390/app10155231.

Full text
Abstract:
This in-vitro study assessed the effect of an underdrilling implant placement protocol on the insertion torque, implant surface temperature and surface roughness (Sa) topography of the cervical microthreads of implants. Three groups of 25 implants (3.75 mm × 10 mm) were placed in osteotomies prepared in an artificial bone disc with final diameters of 3.65 mm according to the manufacturer’s instructions and in osteotomies prepared in accordance with an underdrilling protocol with final drill diameters of 3.2 and 2.8 mm (groups D3.65, D3.2, D2.8, respectively). Implants were inserted at a consta
APA, Harvard, Vancouver, ISO, and other styles
27

Choi, Hoon, Jamie L. Baisden, and Narayan Yoganandan. "A Comparative in vivo Study of Semi-constrained and Unconstrained Cervical Artificial Disc Prostheses." Military Medicine 184, Supplement_1 (March 1, 2019): 637–43. http://dx.doi.org/10.1093/milmed/usy395.

Full text
Abstract:
Abstract Purpose The objective of this study is to directly compare different types of cervical artificial disc implants using an in vivo model capable of simulating the axial load on a neck that is similar to the human neck. Methods Cervical arthroplasty was performed at C3-4 in 14 healthy female adult Alpine goats. The goats were divided into three groups. Group A received Bryan (unconstrained one-piece design); Group B received ProDisc-C (semi-constrained two-piece design); and Group C received Mobi-C (unconstrained three-piece design) artificial discs. The goats were monitored in a veterin
APA, Harvard, Vancouver, ISO, and other styles
28

Goossens, Quentin, Leonard Cezar Pastrav, Michiel Mulier, Wim Desmet, Jos Vander Sloten, and Kathleen Denis. "Two Different Methods to Measure the Stability of Acetabular Implants: A Comparison Using Artificial Acetabular Models." Sensors 20, no. 1 (January 1, 2020): 254. http://dx.doi.org/10.3390/s20010254.

Full text
Abstract:
The total number of total hip arthroplasties is increasing every year, and approximately 10% of these surgeries are revisions. New implant design and surgical techniques are evolving quickly and demand accurate preclinical evaluation. The initial stability of cementless implants is one of the main concerns of these preclinical evaluations. A broad range of initial stability test methods is currently used, which can be categorized into two main groups: Load-to-failure tests and relative micromotion measurements. Measuring relative micromotion between implant and bone is recognized as the golden
APA, Harvard, Vancouver, ISO, and other styles
29

Geertman, M. E., A. P. Slagter, M. A. J. van Waas, and W. Kalk. "Comminution of Food with Mandibular Implant-retained Overdentures." Journal of Dental Research 73, no. 12 (December 1994): 1858–64. http://dx.doi.org/10.1177/00220345940730121101.

Full text
Abstract:
When complete-denture wearers are treated with from four to six implants and mandibular implant-borne prostheses, masticatory performance improves. No significant improvement has been observed with two implants and implant-mucosa-borne overdentures, suggesting that the masticatory performance of edentulous subjects depends on the degree of support for their mandibular prostheses by implants or alveolar mucosa. To verify this hypothesis, we studied, in a randomized clinical trial, the comminution of an artificial test food during mastication. The trial involved the provision of a new maxillary
APA, Harvard, Vancouver, ISO, and other styles
30

Meir, Haya, Alon Sebaoun, Perry Raz, Shifra Levartovsky, Adi Arieli, Raphel Pilo, Zafar Dor, and Ilan Beitlitum. "Evaluation of Implant Stability and Trephination Depth for Implant Removal—An In Vitro Study." Materials 15, no. 12 (June 13, 2022): 4200. http://dx.doi.org/10.3390/ma15124200.

Full text
Abstract:
Malpositioned and broken implants are usually fully osseointegrated; hence, their removal, especially from the lower arch, can be very challenging. Implant removal techniques include reverse torque and trephination. Trephination is an invasive technique that can jeopardize vital structures, cause mandibular fatigue fractures, or lead to osteomyelitis. In this study, we aimed to assess the relationship between trephination depth and implant stability by recording implant stability quotient (ISQ) readings at varying trephination depths in vitro. Materials and methods: Forty-eight implants were i
APA, Harvard, Vancouver, ISO, and other styles
31

Shi, Yun, Ting Deng, Yu Peng, Zugan Qin, Murugan Ramalingam, Yang Pan, Cheng Chen, Feng Zhao, Lijia Cheng, and Juan Liu. "Effect of Surface Modification of PEEK Artificial Phalanx by 3D Printing on its Biological Activity." Coatings 13, no. 2 (February 9, 2023): 400. http://dx.doi.org/10.3390/coatings13020400.

Full text
Abstract:
Objective: Polyetheretherketone (PEEK) is widely used as an orthopedic implant material owing to its good biocompatibility and mechanical strength; however, PEEK implants are biologically inert, resulting in suboptimal cellular responses after implantation. The aim of this study was to enhance the biological activity of PEEK through sulfonation treatment. Methods: In this study, distal phalangeal implants of PEEK were customized by fused deposition modeling (FDM) printing technology and soaked in concentrated sulfuric acid at different times to obtain sulfonated PEEK (SPEEK). The groups were d
APA, Harvard, Vancouver, ISO, and other styles
32

Hodgins, Diana. "Artificial Means for Improving Human Motion." Applied Bionics and Biomechanics 1, no. 2 (2004): 131–32. http://dx.doi.org/10.1155/2004/742983.

Full text
Abstract:
This paper gives a brief description of some of the key ongoing product developments in Europe for medical implants. A range of medical systems that are currently being developed under European-funded programmes are briefly described. The first is an implant that helps people with ‘dropped foot’ improve their walking. Further research on body-worn inertial measuring systems (IMUs) and microsystems will extend the capabilities to other lower-limb and upper-limb applications in the future. Other medical systems being developed with the use of microsystems and nanotechnology include a system to a
APA, Harvard, Vancouver, ISO, and other styles
33

Shepherd, Duncan E. T., and Godfrey Azangwe. "Synthetic Versus Tissue-Engineered Implants for Joint Replacement." Applied Bionics and Biomechanics 4, no. 4 (2007): 179–85. http://dx.doi.org/10.1155/2007/675629.

Full text
Abstract:
Human synovial joints are remarkable as they can last for a lifetime. However, they can be affected by disease that may lead to destruction of the joint surface. The most common treatment in the advanced stages of joint disease is artificial joint replacement, where the diseased synovial joint is replaced with an artificial implant made from synthetic materials, such as metals and polymers. A new technique for repairing diseased synovial joints is tissue engineering where cells are used to grow replacement tissue. This paper explores the relative merits of synthetic and tissue-engineered impla
APA, Harvard, Vancouver, ISO, and other styles
34

Finestone, Sandra. "Personal Experience with Breast Cancer." American Journal of Cosmetic Surgery 14, no. 4 (December 1997): 403–4. http://dx.doi.org/10.1177/074880689701400405.

Full text
Abstract:
One woman's personal experience with breast cancer, breast reconstruction, and breast implants. The article presents the author's conviction that there is no link between breast implants and the various ailments being reported. The author's concern that a woman facing breast cancer or a person requiring an artificial joint may find in the future fewer options available to help in the healing process because of misinformation and the way the media and FDA have handled the silicone gel implant issue.
APA, Harvard, Vancouver, ISO, and other styles
35

Nakanishi, Yoshitaka, Tatsuki Takashima, Hidehiko Higaki, Ken Shimoto, Hiromasa Miura, Yukihide Iwamoto, and Kenji Sunagawa. "WEAR RESISTANCE OF ARTIFICIAL ARTICULAR CARTILAGE FOR JOINT PROSTHESES(2D1 Artificial Organs & Implants II)." Proceedings of the Asian Pacific Conference on Biomechanics : emerging science and technology in biomechanics 2007.3 (2007): S157. http://dx.doi.org/10.1299/jsmeapbio.2007.3.s157.

Full text
APA, Harvard, Vancouver, ISO, and other styles
36

Unger, Felix. "Review article : Current status and use of artificial hearts and circulatory assist devices." Perfusion 1, no. 3 (July 1986): 155–63. http://dx.doi.org/10.1177/026765918600100302.

Full text
Abstract:
In a critical review, current status of artificial hearts and cardiac assist devices is discussed, based on 300000 clinical implantations of intra-aortic balloon pumps, 278 clinical cases of ventricular assist devices and 17 total artificial heart implants. It is justified to implant mechanical hearts as a bridge towards transplantation. Mechanical cardiac assistance has become almost a routine for teams dealing with cardiac transplantation.
APA, Harvard, Vancouver, ISO, and other styles
37

Alnaimat, F. A., H. A. Owida, A. Al Sharah, M. Alhaj, and Mohammad Hassan. "Silicone and Pyrocarbon Artificial Finger Joints." Applied Bionics and Biomechanics 2021 (June 3, 2021): 1–12. http://dx.doi.org/10.1155/2021/5534796.

Full text
Abstract:
Artificial finger joint design has been developed through different stages through the past. PIP (proximal interphalangeal) and MCP (metacarpophalangeal) artificial finger joints have come to replace the amputation and arthrodesis options; although, these artificial joints are still facing challenges related to reactive tissues, reduced range of motion, and flexion and extension deficits. Swanson silicone artificial finger joints are still common due to the physician’s preferability of silicone with the dorsal approach during operation. Nevertheless, other artificial finger joints such as the
APA, Harvard, Vancouver, ISO, and other styles
38

Mehta, Sahil, Gurmohan Singh, Harvinder Singh, and Abhineet Saini. "A Review of Tribological Behavior of Different Bio-Implant Materials." ECS Transactions 107, no. 1 (April 24, 2022): 5147–53. http://dx.doi.org/10.1149/10701.5147ecst.

Full text
Abstract:
Biomedical implants are extensively gaining popularity owing to ever increasing health complications and growth in trauma numbers globally. Metallic implants are the most widely used bio-implants for various orthopedics and dentistry related problems owing to their superior mechanical strength when compared to ceramics and polymers. Furthermore, titanium alloys are the preferred choice these days, because of their proximate nature to human bone and light weight. However, few shortcomings make these artificial bio-implants capricious like short life span, wear rate, surface finish, etc. Tribolo
APA, Harvard, Vancouver, ISO, and other styles
39

Pilliar, R. M., J. E. Davies, and D. C. Smith. "The Bone-Biomaterial Interface for Load-Bearing Implants." MRS Bulletin 16, no. 9 (September 1991): 55–61. http://dx.doi.org/10.1557/s0883769400056074.

Full text
Abstract:
Bone-interfacing surgical implants used in orthopedics and dentistry must bear the forces of normal patient activity with minimal risk of mechanical failure of the implant. This requires using appropriate materials and designs for implant fabrication. Additionally, reliable long-term implant attachment to host bone must be assured so that effective force transfer between implant and bone occurs for the patient's lifetime without the implant loosening. With recent advances in implant designs and techniques for their placement, effective implant fixation to bone can last for years (decades) eith
APA, Harvard, Vancouver, ISO, and other styles
40

Romanos, Georgios E., Daniel J. Bastardi, Rachel Moore, Apoorv Kakar, Yaro Herin, and Rafael A. Delgado-Ruiz. "In Vitro Effect of Drilling Speed on the Primary Stability of Narrow Diameter Implants with Varying Thread Designs Placed in Different Qualities of Simulated Bone." Materials 12, no. 8 (April 25, 2019): 1350. http://dx.doi.org/10.3390/ma12081350.

Full text
Abstract:
It is hypothesized that there is no statistically significant impact of drilling speed (DS) on the primary stability (PS) of narrow-diameter implants (NDIs) with varying thread designs placed in dense and soft simulated bone. The aim of this in vitro study was to evaluate the impact of DS on the PS of NDIs with varying thread designs placed in dense and soft simulated bone. Two hundred and forty osteotomies for placement of various implant macro-designs were divided into three groups (80 implants per group): Group A (NobelActive, 3.0/11.5 mm); Group B (Astra OsseoSpeed-EV, 3.0/11 mm); and Grou
APA, Harvard, Vancouver, ISO, and other styles
41

Senior, Kathryn. "Artificial implants: making the marriage work." Lancet 354, no. 9178 (August 1999): 576. http://dx.doi.org/10.1016/s0140-6736(05)77930-7.

Full text
APA, Harvard, Vancouver, ISO, and other styles
42

Morgan, R. "Artificial implants and soft tissue sarcomas." Journal of Clinical Epidemiology 48, no. 4 (April 1995): 545–49. http://dx.doi.org/10.1016/0895-4356(94)00211-8.

Full text
APA, Harvard, Vancouver, ISO, and other styles
43

Fields, R. Douglas, Jean M. Le Beau, Frank M. Longo, and Mark H. Ellisman. "Nerve regeneration through artificial tubular implants." Progress in Neurobiology 33, no. 2 (January 1989): 87–134. http://dx.doi.org/10.1016/0301-0082(89)90036-1.

Full text
APA, Harvard, Vancouver, ISO, and other styles
44

Hall, C. William. "When Did Artificial Heart Implants Begin?" JAMA: The Journal of the American Medical Association 259, no. 11 (March 18, 1988): 1650. http://dx.doi.org/10.1001/jama.1988.03720110020023.

Full text
APA, Harvard, Vancouver, ISO, and other styles
45

Hall, C. W. "When did artificial heart implants begin?" JAMA: The Journal of the American Medical Association 259, no. 11 (March 18, 1988): 1650. http://dx.doi.org/10.1001/jama.259.11.1650.

Full text
APA, Harvard, Vancouver, ISO, and other styles
46

Romanos, Georgios E., Rafael Arcesio Delgado-Ruiz, and Ana I. Nicolas-Silvente. "Volumetric Changes in Morse Taper Connections After Implant Placement in Dense Bone. In-Vitro Study." Materials 13, no. 10 (May 16, 2020): 2306. http://dx.doi.org/10.3390/ma13102306.

Full text
Abstract:
The stability of the implant–abutment interface is crucial for the maintenance of the implant index integrity. Several factors are capable of inducing deformation in implant–abutment connection, such as the actual insertion of the implant into the bone. This study aimed to evaluate the deformations produced in the connection after the insertion of the implant. Ten implants with two different implant carriers (Type A: carrier attached to platform and Type B: carrier attached inside the index-connection) were placed in artificial Type II bone, and volumetric changes were evaluated for different
APA, Harvard, Vancouver, ISO, and other styles
47

Musiienko, Olha, Vitalii Parii, Oleksii Morhun, and Viktor Koval. "Influence of the angle of dental implant placement on the stress-strain state of the jaw." Ukrainian Scientific Medical Youth Journal 144, no. 1 (March 28, 2024): 98–104. http://dx.doi.org/10.32345/usmyj.1(144).2024.98-104.

Full text
Abstract:
prosthetics on dental implants is a complex and responsible stage of treatment of patients with dental defects. The success of dental implantation depends not only on careful planning and performed surgical intervention in compliance with the requirements of the protocol, but also on the type of load on the dental implant, the choice of orthopedic design and material. Thorough preparation for prosthetics, taking into account the initial clinical situation and individual characteristics of the patient, ensures a full restoration of the dentition defect with reproduction of the chewing function.
APA, Harvard, Vancouver, ISO, and other styles
48

Ylinen, P., R. M. Tulamo, M. Kellomäki, P. Türmälä, P. Rokkanen, and T. Palmgren. "Lumbar intervertebral disc replacement using bioabsorbable self-reinforced poly-L-lactide full-threaded screws, or cylindrical implants of polylactide polymers, bioactive glass and Polyactive™." Veterinary and Comparative Orthopaedics and Traumatology 16, no. 03 (July 2003): 138–44. http://dx.doi.org/10.1055/s-0038-1632777.

Full text
Abstract:
SummaryIntervertebral disc surgery leads to changes in the segmental anatomy and mobility, and subsequently to degenerative changes in the lumbar spine. Artificial intervertebral disc implants sufficient to replace the human lumbar intervertebral disc have been developed and the requirements for these defined. This is to our knowledge the first study on bioabsorbable intervertebral disc replacement implants. SR-PLLA screws, previously used in orthopaedic internal fixations, and cylindrical implants, specifially developed for this experimental preliminary study, were used to replace lumbar inte
APA, Harvard, Vancouver, ISO, and other styles
49

Batista, N. A., A. A. Rodrigues, V. P. Bavaresco, J. R. L. Mariolani, and W. D. Belangero. "Polyvinyl Alcohol Hydrogel Irradiated and Acetalized for Osteochondral Defect Repair: Mechanical, Chemical, and Histological Evaluation after Implantation in Rat Knees." International Journal of Biomaterials 2012 (2012): 1–9. http://dx.doi.org/10.1155/2012/582685.

Full text
Abstract:
Polyvinyl Alcohol (PVA) hydrogel plugs were implanted in artificial osteochondral defects on the trochlear groove of rat knees. After 0, 3, 6, 12, and 24 weeks of followup, samples containing the implants were mechanically evaluated by creep indentation test, chemically, and histologically by optical microscopy. The mechanical test pointed towards an increase of the implant creep modulus and the chemical analysis exhibited an increasing concentration of calcium and phosphorus within the implants over time. Optical microscopy showed no foreign body reaction and revealed formation, differentiati
APA, Harvard, Vancouver, ISO, and other styles
50

Ding, Zihan. "Recent Progress of Nanomaterials in Implants." Highlights in Science, Engineering and Technology 40 (March 29, 2023): 142–48. http://dx.doi.org/10.54097/hset.v40i.6584.

Full text
Abstract:
With the continuous development of nanotechnology and the increasing emphasis on physical fitness, the age of onset of bone diseases is becoming younger and younger. Bone tissue engineering and artificial joint replacement surgery, with the application of bio-materials as implants, are considered as promising approaches to treat bone diseases. Among various bio-materials, Implants made of nanomaterials with appropriate biocompatibility and biomechanical properties can be used clinically to address some of the problems associated with bone disease. This paper reviews the use of nanoceramic and
APA, Harvard, Vancouver, ISO, and other styles