Academic literature on the topic 'Beam-to-column joint'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Beam-to-column joint.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "Beam-to-column joint"

1

Vimal Arokiaraj, G., and G. Elangovan. "A Study on Self-Consolidate Concrete in Experimental Reinforced-Concrete Beam Column Structures with Alccofine and Steel Fiber." Advances in Civil Engineering 2022 (October 31, 2022): 1–19. http://dx.doi.org/10.1155/2022/7874066.

Full text
Abstract:
This paper discusses the concept of self-consolidating concrete mix with Alccofine-1203, superplasticizer, viscosity modification agent, crimped steel fiber on the RC beam column joint. Totally, eight reinforced-concrete (RC) column joints with M25 grade concrete were considered in this study. Out of eight RC beam column joints, two beam column joints served as Alccofine, two beam column joint specimens served as Alccofine 5%, two beam column joint specimens served as Alccofine-10%, and two beam column joint specimens served as Alccofine-15%. All the RC beam column joint specimens were tested
APA, Harvard, Vancouver, ISO, and other styles
2

Urbonas, Kestutis, and Alfonsas Daniūnas. "COMPONENT METHOD EXTENSION TO STEEL BEAM‐TO‐BEAM AND BEAM‐TO‐COLUMN KNEE JOINTS UNDER BENDING AND AXIAL FORCES." JOURNAL OF CIVIL ENGINEERING AND MANAGEMENT 11, no. 3 (2005): 217–24. http://dx.doi.org/10.3846/13923730.2005.9636353.

Full text
Abstract:
This paper presents an analysis of semi‐rigid beam‐to‐beam end‐plate bolted and beam‐to‐column end‐plate bolted knee joints that are subjected to bending and tension or compression axial force. Usually the influence of axial force on joint rigidity is neglected. According to EC3, the axial load, which is less than 10 % of plastic resistance of the connected member under axial force, may be disregarded in the design of joint. Actually the level of axial forces in joints of structures may be significant and has a significant influence on joint rigidity. One of the most popular practical method p
APA, Harvard, Vancouver, ISO, and other styles
3

Gombosuren, Dagvabazar, and Takeshi Maki. "Prediction of Joint Shear Deformation Index of RC Beam–Column Joints." Buildings 10, no. 10 (2020): 176. http://dx.doi.org/10.3390/buildings10100176.

Full text
Abstract:
In the analysis of reinforced concrete (RC) buildings, beam–column joints are regarded as rigid nodes. In fact, joint deformation may make a significant difference in the lateral response of RC buildings if joints are not properly designed and detailed. To consider joint flexibility, several types of joint models have been proposed. However, these models require complicated computations, consequently making them challenging to apply in engineering practice. This paper proposed a simple approach for predicting the contribution of the joint deformation to the total deformation of RC interior bea
APA, Harvard, Vancouver, ISO, and other styles
4

Guo, Rui, Dan Yang, Bin Jia, and Deyun Tang. "Seismic Response of GFRP-RC Interior Beam-to-Column Joints under Cyclic Static Loads." Buildings 12, no. 11 (2022): 1987. http://dx.doi.org/10.3390/buildings12111987.

Full text
Abstract:
A total of nine specimens were constructed and tested under cyclic loads to investigate the differences in seismic behavior between glass fiber-reinforced polymer (GFRP)-reinforced concrete (RC) joints and RC beam-to-column joints. The experimental parameters included stirrup ratios, axial pressure ratios and concrete strength of the beam-to-column joints. The cyclic loading test results showed that the GFRP-RC beam-to-column joints can withstand significantly high lateral deformations without exhibiting brittle failure. Moreover, the RC beam-to-column joint exhibited significantly higher ener
APA, Harvard, Vancouver, ISO, and other styles
5

Desta, Negasa, Kabtamu Getachew, and Daba Geresu. "Numerical Investigation of Textile Reinforced Cement Structural Stay-in-Place Formwork Designed as Beam-Column Joint Shear Reinforcement." Advances in Civil Engineering 2022 (June 30, 2022): 1–24. http://dx.doi.org/10.1155/2022/4644433.

Full text
Abstract:
This study investigates the feasibility and structural performance of textile reinforced cement (TRC) stay-in-place (SiP) formwork designed as shear reinforcement for beam-column joints under monotonic loading through the nonlinear finite element package ABAQUS. This was achieved by conducting numerical analysis on 24 beam-column joints using different parameters that affect the joints’ performance, including column axial load ratio, concrete compressive strength, beam tensile reinforcement ratio, joint shear reinforcement ratio, and thickness of TRC. The models were first calibrated to the re
APA, Harvard, Vancouver, ISO, and other styles
6

Hwang, Hyeon-Jong, and Chang-Soo Kim. "Simplified Plastic Hinge Model for Reinforced Concrete Beam–Column Joints with Eccentric Beams." Applied Sciences 11, no. 3 (2021): 1303. http://dx.doi.org/10.3390/app11031303.

Full text
Abstract:
In nonlinear analysis for performance-based design of reinforced concrete moment frames, a plastic hinge spring element is predominantly used in order to simply and accurately describe the inelastic behavior of beam–column joints, including strength degradation. Although current design codes and guidelines provide various beam–column joint models, the focus is on concentric beam–column joints. Therefore, more studies are required for eccentric beam–column joints, which are also common in practice. In the present study, to consider the effect of beam eccentricity on the behavior of beam–column
APA, Harvard, Vancouver, ISO, and other styles
7

Li, Yunan, Xian Dong, Zhan Wang, Jiajun Li, and Ke Qin. "Research on Mechanical Properties of Angle Beam-column Joint with Gusset plate." E3S Web of Conferences 233 (2021): 03031. http://dx.doi.org/10.1051/e3sconf/202123303031.

Full text
Abstract:
There is wide use of beam-column joint with gusset plate angle connection in engineering, however, the mechanical properties of these joints are still lack of complete theoretical and experimental research. This kind of joint is often simplified as an articulated connection or other types of connections in the design. In this paper, experimental study and finite element analysis are carried out to study the flexural behavior of the beam-column joint with gusset plate angle connection. The finite element analysis is used to analyze the differences between the beam-column joint with gusset plate
APA, Harvard, Vancouver, ISO, and other styles
8

James, Jerison Scariah, and Margrette Mary James. "Effect of Fibres on Beam Column Joint Failure." Applied Mechanics and Materials 857 (November 2016): 59–64. http://dx.doi.org/10.4028/www.scientific.net/amm.857.59.

Full text
Abstract:
Concrete is one of the most resourceful and environmental friendly building materials. It can be cast to fit any structural shape from a cylindrical water storage tank to a rectangular beam, slabs and column in a high-rise building. In RC buildings, portions of columns that are common to beams at their intersections are called beam column joints. Beam-column joints have a crucial role in the structural integrity of the buildings. Review of literature indicates that numerous studies were conducted in the past to study the behaviour of beam-column joints with normal concrete. However, those reco
APA, Harvard, Vancouver, ISO, and other styles
9

Purnomo, Joko, V. Octaviani, P. K. Chiaulina, and Jimmy Chandra. "Evaluation of a Macro Lump Plasticity Model for Reinforced Concrete Beam-Column Joint under Cyclic Loading." Civil Engineering Dimension 22, no. 2 (2020): 82–93. http://dx.doi.org/10.9744/ced.22.2.81-92.

Full text
Abstract:
Lateral deformations of reinforced concrete (RC) frames under extreme seismic excitation are highly affected by the stiffness of their beam-column joints. Numerous models have been proposed to simulate the responses of RC beam-column joint under cyclic loading. Development of RC beam-column joint model based on macro modeling using spring elements becomes more popular because of its considerably simple application for seismic performance evaluation purposes. In this study, a simple modification to previously developed macro-spring element-based model for RC beam-column joint is done and is use
APA, Harvard, Vancouver, ISO, and other styles
10

Zhang, Xizhi, Jiashu Hao, Dongchao Duan, Shengbo Xu, Shaohua Zhang, and Houxin Yu. "Experimental study on bolted and anchored beam-to-column joints of prefabricated concrete frames." Advances in Structural Engineering 23, no. 2 (2019): 374–87. http://dx.doi.org/10.1177/1369433219872432.

Full text
Abstract:
A new type of beam-to-column joint used in prefabricated concrete frames was proposed in this study. In this joint, the longitudinal bars at the top of the beam are anchored to the column using straight thread sleeves, and the bars at the bottom are welded to the steel fastener that is bolted to the column. Cyclic loading tests of three specimens, namely, two beam–column joints of this type and a cast-in-place beam–column joint, were conducted to study the seismic behavior and feasibility of this type of joint. The difference between the two prefabricated joints is the shape of the holes on th
APA, Harvard, Vancouver, ISO, and other styles

Dissertations / Theses on the topic "Beam-to-column joint"

1

Unal, Mehmet. "Analytical Modeling Of Reinforced Concrete Beam-to-column Connections." Master's thesis, METU, 2010. http://etd.lib.metu.edu.tr/upload/12612230/index.pdf.

Full text
Abstract:
Prior studies indicated that beam-to-column connections of reinforced concrete (RC) moment resisting frame structures experience considerable deformations under earthquake loading and these deformations have a major contribution to story drift of the building. In current analysis and design applications, however, the connection regions are generally modeled as rigid zones and the inelastic behavior of the joint is not taken into account. This assumption gives rise to an underestimation of the story drifts and hence to an improper assessment of the seismic performance of the structure. In order
APA, Harvard, Vancouver, ISO, and other styles
2

Mazzarolo, Enrico. "Analysis and Development of an Innovative Prefabricated Beam-to-Column Joint." Doctoral thesis, Università degli studi di Trento, 2012. https://hdl.handle.net/11572/367656.

Full text
Abstract:
The use of pre-fabricated concrete components and their related coupling systems in seismic engineering constitutes a subject of wide and deep interest among researchers, practitioners and manufacturers all over the world, as demonstrated by a large number of studies conducted, among other Countries, especially in Japan, New Zealand and United States since the early ‘80s and, in relatively more recent times, in Italy. A key issue is given by the possibility to apply the typical benefits of the pre-fabrication not only to low rise industrial/commercial structures, but also to multi-storey fra
APA, Harvard, Vancouver, ISO, and other styles
3

Yang, Jie. "Structural behaviour of concrete-filled elliptical column to I-beam connections." Thesis, University of Bradford, 2017. http://hdl.handle.net/10454/16022.

Full text
Abstract:
Concrete-filled tubular (CFT) columns have been widely adopted in building structures owing to their superior structural performance, such as enhanced load bearing capacity, compared to hollow tubes. Circular, square and rectangular hollow sections are most commonly used in the past few decades. Elliptical hollow section (EHS) available recently is regarded as a new cross-section for the CFT columns due to its attractive appearance, optional orientation either on major axis or minor axis and improved structural efficiency. The state of the research in terms of elliptical columns, tubular joint
APA, Harvard, Vancouver, ISO, and other styles
4

SILVA, RAQUEL ALVES CABRAL. "THEORETICAL AND EXPERIMENTAL ANALYSIS OF A COMPOSITE SEMI-RIGID BEAM-TO-COLUMN JOINT USING PERFOBOND SHEAR CONNECTORS." PONTIFÍCIA UNIVERSIDADE CATÓLICA DO RIO DE JANEIRO, 2015. http://www.maxwell.vrac.puc-rio.br/Busca_etds.php?strSecao=resultado&nrSeq=27553@1.

Full text
Abstract:
PONTIFÍCIA UNIVERSIDADE CATÓLICA DO RIO DE JANEIRO<br>COORDENAÇÃO DE APERFEIÇOAMENTO DO PESSOAL DE ENSINO SUPERIOR<br>PROGRAMA DE EXCELENCIA ACADEMICA<br>Nos projetos de engenharia é comum desconsiderar-se o comportamento semirrígido das ligações, ou seja, as ligações são assumidas com as condições ideais de rigidez. A primeira condição ideal é aquela na qual há transferência total de momento fletor, assumindo-se que não existe rotação relativa entre os elementos ligados, estas ligações são as chamadas rígidas. Na segunda opção, a transferência de momento fletor é desconsiderada e a ligação é
APA, Harvard, Vancouver, ISO, and other styles
5

Dissanayake, Udaya Indrajith. "The influence of the composite beam-to-steel column joint on the behaviour of composite beams in frames." Thesis, University of Sheffield, 1996. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.389752.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

[Verfasser], Saenboon Amorntipsakul. "Generic Finite Element Model for Mechanically Consistent Scaling of Composite Beam-to-column Joint with Welded Connection / Saenboon Amorntipsakul." Kassel : Universitätsbibliothek Kassel, 2013. http://d-nb.info/1041369263/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Motamed, Jubin. "Monolithic beam to external column joints in reinforced concrete." Thesis, University of Westminster, 2010. https://westminsterresearch.westminster.ac.uk/item/90727/monolithic-beam-to-external-column-joints-in-reinforced-concrete.

Full text
Abstract:
The benefits of high strength concrete (HSC) in the construction of multi-storey buildings are commonly acknowledged. Past researchers have investigated the suitability of design codes for the use of HSC [1]. However, there are concerns about the shear behaviour of HSC beams and BCJ used in the construction of these buildings. HSC beams have equal or less shear resistance compared to normal strength concrete (NSC) beams [2], and the brittleness of HSC material could be unsuitable for BCJ as confinement stirrups may not be as effective as NSC in the column due to a smaller Poisson’s ratio. This
APA, Harvard, Vancouver, ISO, and other styles
8

Rifai, Abdussalam Mahmud. "Behaviour of columns in sub-frames with semi-rigid joints." Thesis, University of Sheffield, 1987. http://etheses.whiterose.ac.uk/3050/.

Full text
Abstract:
The behaviour of limited subassemblages with flexible beans and semi-rigid beam to column connections was studied using a computer program in which the finite element method was employed in a non-linear analysis which accounts for the presence of semi-rigid connections and the inelastic behaviour of frames. The program accounts for many other factors such as initial imperfections and residual stresses. The theoretical background to the present computer program has been presented along with the program layout. The program was used to simulate some of the experimental results obtained from tests
APA, Harvard, Vancouver, ISO, and other styles
9

Bernardi, Martina. "Industrial steel storage racks subjected to static and seismic actions: an experimental and numerical study." Doctoral thesis, Università degli studi di Trento, 2021. http://hdl.handle.net/11572/322402.

Full text
Abstract:
Industrial steel storage racks are pre-engineered lightweight structures commonly used to store goods from supermarkets to big warehouses. These systems are framed structures, usually made of cold-formed steel profiles and characterised by non-standard details. Their performance is quite complex and the prediction of their global response is more difficult than for the traditional steel frames. This difficulty is due to the racks’ main features: the use of cold-formed thin-walled steel sections which are sensitive to different buckling modes, the presence of regular perforation patterns on the
APA, Harvard, Vancouver, ISO, and other styles
10

Leong, Mun-Foo. "MOMENT-ROTATION CHARACTERISTICS OF BEAM-TO-COLUMN CONNECTIONS." Thesis, The University of Arizona, 1985. http://hdl.handle.net/10150/275028.

Full text
APA, Harvard, Vancouver, ISO, and other styles

Books on the topic "Beam-to-column joint"

1

1936-, Chen Wai-Fah, ed. Steel beam-to-column building connections. Elsevier Applied Science, 1988.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
2

Joint model to simulate inelastic shear behavior of poorly detailed exterior and interior beam-column connections reinforeced with deformed bars under seismic excitations. Bhabha Atomic Research Centre, 2009.

Find full text
APA, Harvard, Vancouver, ISO, and other styles

Book chapters on the topic "Beam-to-column joint"

1

Son, M. P., G. G. Kashevarova, and A. D. Zemlyanukhin. "Development of Flexible Joint for Beam-to-Column Abutment." In Proceedings of the 5th International Conference on Construction, Architecture and Technosphere Safety. Springer International Publishing, 2022. http://dx.doi.org/10.1007/978-3-030-91145-4_6.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Peng, Chengwei, and Wenlong Lv. "Experimental Study on Mechanical Properties of the Damaged Hoop Head Mortise-Tenon Joint." In Advances in Frontier Research on Engineering Structures. Springer Nature Singapore, 2023. http://dx.doi.org/10.1007/978-981-19-8657-4_35.

Full text
Abstract:
AbstractDamage is a common condition in ancient timber structures, whose influence on the mechanical properties of structures cannot be ignored. To study the mechanical properties of damaged hoop head mortise-tenon joint, four specimens with shrinkage gauge, including one intact joint specimen and three artificial simulated damaged joint specimens, are designed, and fabricated in this paper by regarding the global damage degree and column axial force as the variation of parameters. The failure mode, hysteresis curve, skeleton curve, ductility, and energy dissipation capacity of the specimens are studied by low-cyclic reversed loading tests. The results show that the failure pattern is randomly manifested as parallel-to-grain tensile cracking failure or vertical splitting failure of the beam tenon. When the global damage degree increases, the two types of damage are more likely to appear simultaneously. The global damage degree has a significant influence on the ultimate bending moment and energy dissipation capacity of hoop head mortise-tenon joints, and 2.4% of the global damage degree can lead to a significant decrease in both. The column axial force can affect the ultimate bending moment, ductility, and energy dissipation capacity of hoop head mortise-tenon joints. When the column axial force increases, the ultimate bending moment and energy dissipation capacity will increase, while the ductility will decrease.
APA, Harvard, Vancouver, ISO, and other styles
3

Ye, Dongchen, Yiyi Chen, Gang Zhao, and Qingjun Shi. "Study on an Innovative H-Beam to SHS-Column Joint with Cast Column-Link in Steel Frames." In Lecture Notes in Civil Engineering. Springer Singapore, 2020. http://dx.doi.org/10.1007/978-981-15-8079-6_128.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Kasar, Arnav Anuj, Rupen Goswami, S. D. Bharti, and M. K. Shrimali. "Influence of Joint Panel Zone on Seismic Behaviour of Beam-to-Column Connections." In Advances in Structural Engineering. Springer India, 2014. http://dx.doi.org/10.1007/978-81-322-2193-7_73.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Ghowsi, Ahmad Fayeq, M. Adil Dar, and A. R. Dar. "Behaviour of RC Beam-Column Joint Subjected to Opening Moments: Test and Numerical Validation." In RILEM Bookseries. Springer International Publishing, 2020. http://dx.doi.org/10.1007/978-3-030-51485-3_18.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Swapnil, B., and T. Palanisamy. "Intelligent Modeling for Shear Strength of RC Exterior Beam-Column Joint Subjected to Seismic Loading." In Lecture Notes in Civil Engineering. Springer International Publishing, 2022. http://dx.doi.org/10.1007/978-3-031-12011-4_4.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Chen, Peng, Fangxin Hu, Jianrong Pan, and Zhan Wang. "Seismic Performance of Steel Beam-To-Column Joint with Replaceable Buckling-Restrained Energy Dissipation Fuses." In Lecture Notes in Civil Engineering. Springer International Publishing, 2022. http://dx.doi.org/10.1007/978-3-031-03811-2_90.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Fleury, F., O. Merabet, and J. M. Reynouard. "Steel-concrete bond model: Finite element analysis of a beam-column joint subjected to cyclic alternate loading." In European Seismic Design Practice. Routledge, 2022. http://dx.doi.org/10.1201/9780203756492-60.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Purwanto, Edy, P. Amarta Adri, S. A. Kristiawan, Senot Sangadji, and S. Halwan Alfisa. "Strengthening of Non-engineered Building Beam-Column Joint to Increase Seismic Performance with Variation of Steel Plate Width." In Proceedings of the 5th International Conference on Rehabilitation and Maintenance in Civil Engineering. Springer Nature Singapore, 2022. http://dx.doi.org/10.1007/978-981-16-9348-9_19.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Dujmović, Darko, Boris Androić, and Ivan Lukačević. "Beam to Column Joints." In Composite Structures According to Eurocode 4. Wiley-VCH Verlag GmbH, 2015. http://dx.doi.org/10.1002/9783433604908.ch26.

Full text
APA, Harvard, Vancouver, ISO, and other styles

Conference papers on the topic "Beam-to-column joint"

1

Streppone, Simona, and Magdalini Titirla. "Finite element modelling of RC beam-to-column joint." In INTERNATIONAL CONFERENCE OF NUMERICAL ANALYSIS AND APPLIED MATHEMATICS ICNAAM 2020. AIP Publishing, 2022. http://dx.doi.org/10.1063/5.0085615.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Jayanthi, V. "Performance Evaluation of RCC Beam Column Joint with Aramid Fibre." In Sustainable Materials and Smart Practices. Materials Research Forum LLC, 2022. http://dx.doi.org/10.21741/9781644901953-2.

Full text
Abstract:
Abstract-In reinforced concrete structure beam, the beam column joints are more crucial zones which are most susceptible to failure during earthquake excitation. It is very important to design the joint to dissipate the large amount of energy to the neighbouring elements without loss of strength and ductility. Several retrofitting methods are employed to strengthen the beam column joint. The effective method one among is Fibre Reinforced Polymer (FRP) composites. In this paper, the deflection of beam column joint wrapped with aramid fibre has been calculated and it is compared with Ansys softw
APA, Harvard, Vancouver, ISO, and other styles
3

Istrefi, Florim. "Classification of framed systems based on beam-to-column joint performance." In University for Business and Technology International Conference. University for Business and Technology, 2017. http://dx.doi.org/10.33107/ubt-ic.2017.56.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Sabariman, Bambang, and Mochamad Firmansyah Sofianto. "Study of crack patterns in beam column joint due to upwards anchoring beam effect." In GREEN PROCESS, MATERIAL, AND ENERGY: A SUSTAINABLE SOLUTION FOR CLIMATE CHANGE: Proceedings of the 3rd International Conference on Engineering, Technology, and Industrial Application (ICETIA 2016). Author(s), 2017. http://dx.doi.org/10.1063/1.4985500.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Kunii, Michihiro, Daisuke Tsukishima, and Mareki Kuraoka. "Study on improvement of strength of Beam-column Joints at railway RC rigid-framed viaducts." In IABSE Congress, New York, New York 2019: The Evolving Metropolis. International Association for Bridge and Structural Engineering (IABSE), 2019. http://dx.doi.org/10.2749/newyork.2019.0683.

Full text
Abstract:
&lt;p&gt;In Japan, in order to make the city centering around the station, we are developing the underpass of the station as a commercial facility. Therefore, a structure that enlarges the column span and reduces the cross-sectional height of the beam to widen the under-elevated space is desired. However, while the amount of reinforcing bars increases, the beam-column joints become smaller, so that the reinforcing bars are overcrowded in the beam column joints. In addition, since the fixing length of the reinforcing bars is insufficient, or the strength of the beam-column joint cannot be suffi
APA, Harvard, Vancouver, ISO, and other styles
6

Bradford, Mark Andrew. "Deconstructable Flush End Plate Beam-to-Column Composite Joints: Component- Based Modelling." In 12th international conference on ‘Advances in Steel-Concrete Composite Structures’ - ASCCS 2018. Universitat Politècnica València, 2018. http://dx.doi.org/10.4995/asccs2018.2018.7296.

Full text
Abstract:
Within a paradigm of designing building structures for their end-of-life deconstruction, thispaper addresses flush end plate beam-to-column composite joints that may be dis-assembledand reused elsewhere. The joints consist of steel beams bolted to steel columns, and these aremade composite over the joint with precast concrete slabs attached to the top flange of thesteel beams with post-tensioned high strength bolted shear connectors installed in clearanceholes. Joints of this type experience partial shear connection, and accordingly their designneeds to incorporate this effect. Experimental wo
APA, Harvard, Vancouver, ISO, and other styles
7

Khonsari, S. V., G. L. England, M. Shahsavar-Gargari, and S. M. H. Parvinnia. "Response of a Novel Beam-to-Column Connection to Monotonic and Cyclic Flexural Loading." In ASME 2008 27th International Conference on Offshore Mechanics and Arctic Engineering. ASMEDC, 2008. http://dx.doi.org/10.1115/omae2008-57685.

Full text
Abstract:
A new beam-to-column joint with high rotational as well as shear deformation capacity was devised. This high rotational ‘capacity’ is required to fulfill the great ‘demand’ for rotation arising during earthquakes, severe waves and current loads, etc. Due to its ability to contain damage during an overload, it leaves the connected elements intact. This, together with its replaceability can reduce the cost of post-event repair substantially. Its bending as well as shear performance under “monotonic” loading had already been assessed experimentally (OMAE’02-28864, OMAE’03-37292, OMAE’04-51494 &am
APA, Harvard, Vancouver, ISO, and other styles
8

Hassanshahi, Omid, Taksiah A. Majid, Tze Liang Lau, Ali Yousefi, and R. M. K. Tahara. "Seismic performance of the typical RC beam–column joint subjected to repeated earthquakes." In PROCEEDINGS OF THE INTERNATIONAL CONFERENCE OF GLOBAL NETWORK FOR INNOVATIVE TECHNOLOGY AND AWAM INTERNATIONAL CONFERENCE IN CIVIL ENGINEERING (IGNITE-AICCE’17): Sustainable Technology And Practice For Infrastructure and Community Resilience. Author(s), 2017. http://dx.doi.org/10.1063/1.5005755.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

TAN, Kang Hai, and KANG CHEN. "BEHAVIOUR OF STEEL AND COMPOSITE BEAM-COLUMN JOINTS SUBJECTED TO QUASI-STATIC AND IMPACT LOADS." In 12th international conference on ‘Advances in Steel-Concrete Composite Structures’ - ASCCS 2018. Universitat Politècnica València, 2018. http://dx.doi.org/10.4995/asccs2018.2018.7140.

Full text
Abstract:
The behaviour of steel and composite beam-column joints was investigated in this paper. A test programme on typical beam-column joints subjected to quasi-static and impact loads was presented. A comparison of different connections was conducted and composite slab effect was investigated. Based on the test results, a component-based modelling approach was proposed and validated. Basic nonlinear springs of beam-column joint models were developed. Mechanical properties of the nonlinear springs were defined based on either current design codes or models proposed by previous researchers. Good agree
APA, Harvard, Vancouver, ISO, and other styles
10

Nakaue, Shinya, and Yasushi Nishimura. "Improvement of bearing performance on exterior steel beam-reinforced concrete column joints with steel column." In 12th international conference on ‘Advances in Steel-Concrete Composite Structures’ - ASCCS 2018. Universitat Politècnica València, 2018. http://dx.doi.org/10.4995/asccs2018.2018.7077.

Full text
Abstract:
To improve the bearing failure behavior of the exterior steel beam-reinforced concrete column joints composed of reinforced concrete columns, joint details using steel column was proposed. Steel column was attached to the lower flanges at right angles to the steel flange. The objective of this study is to clarify the effectiveness of proposed joint details experimentally and theoretically. To clarify the influence of steel column on the bearing failure of the joint, seven T-shaped subassemblages were tested under reversed cyclic loading. All specimens had the same cross sections of the steel b
APA, Harvard, Vancouver, ISO, and other styles

Reports on the topic "Beam-to-column joint"

1

Nema, Arpit, and Jose Restrep. Low Seismic Damage Columns for Accelerated Bridge Construction. Pacific Earthquake Engineering Research Center, University of California, Berkeley, CA, 2020. http://dx.doi.org/10.55461/zisp3722.

Full text
Abstract:
This report describes the design, construction, and shaking table response and computation simulation of a Low Seismic-Damage Bridge Bent built using Accelerated Bridge Construction methods. The proposed bent combines precast post-tensioned columns with precast foundation and bent cap to simplify off- and on-site construction burdens and minimize earthquake-induced damage and associated repair costs. Each column consists of reinforced concrete cast inside a cylindrical steel shell, which acts as the formwork, and the confining and shear reinforcement. The column steel shell is engineered to fa
APA, Harvard, Vancouver, ISO, and other styles
2

Chen, Xuesen, and Gang Shi. EXPERIMENTAL STUDY OF COVER-PLATE BEAM-TO-COLUMN JOINTS IN HIGH-STRENGTH STEEL FRAMES. The Hong Kong Institute of Steel Construction, 2018. http://dx.doi.org/10.18057/icass2018.p.039.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Liu, Muming, and Gang Shi. CYCLIC LOADING TESTS OF DUPLEX STAINLESS STEEL BEAM-TO-COLUMN JOINTS WITH WUF-W CONNECTION. The Hong Kong Institute of Steel Construction, 2018. http://dx.doi.org/10.18057/icass2018.p.050.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Dan, Gan, Yan Feng, Cheng Rui, and Zhou Xuhong. CYCLIC TESTS OF CONCRETE-FILLED U-SHAPED STEEL BEAM TO CONCRETE-FILLED SQUARE STEEL TUBE COLUMN JOINTS. The Hong Kong Institute of Steel Construction, 2018. http://dx.doi.org/10.18057/icass2018.p.031.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Gao, Jun-Dong, Huan-Xin Yuan, and Xin-Xi Du. NUMERICAL STUDY ON STRUCTURAL BEHAVIOUR OF STAINLESS STEEL BEAM-TO-COLUMN JOINTS WITH DOUBLE EXTENDED END-PLATE CONNECTIONS. The Hong Kong Institute of Steel Construction, 2018. http://dx.doi.org/10.18057/icass2018.p.157.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

STUDY ON THE STATIC BEHAVIOR OF COLD-FORMED STEEL FABRICATED BEAM-COLUMN JOINT. The Hong Kong Institute of Steel Construction, 2022. http://dx.doi.org/10.18057/icass2020.p.310.

Full text
Abstract:
This paper presents a new built-up beam-column joint with a spacer employed between channel sections under monotonic loading to study its static behavior. A validated finite element model was used to simulate the cold-formed steel (CFS) joint's moment-rotation behavior and failure mode by utilizing ABAQUS. It accounts for both material and geometrical nonlinearity. The model was further adopted to investigate the influence of bolt arrangement, spacing of intermediate connecting plates, diaphragms and various beam-column stiffness ratios on the joint behavior. The results indicate that the bolt
APA, Harvard, Vancouver, ISO, and other styles
7

ANALYSIS AND DESIGN OF AXIALLY LOADED SQUARE CFST COLUMN TO RC BEAM JOINTS STIFFENED BY DIAGONAL RIBS. The Hong Kong Institute of Steel Construction, 2023. http://dx.doi.org/10.18057/ijasc.2023.19.1.6.

Full text
Abstract:
This work proposes a partially through-beam joint system to connect square concrete-filled steel tubular (CFST) columns and reinforced concrete (RC) beams. In the system, the holes in the steel tube allow longitudinal beam reinforcements to be continuous through the joint zone to achieve direct load-transfer of the beam, and the square steel tube with holes is strengthened by welding diagonal ribs located at the corners of the steel tube. Finite element (FE) analyses on joints with RC beams were carried out based on verified models. The analysis results showed that diagonal ribs welded to the
APA, Harvard, Vancouver, ISO, and other styles
8

CHARACTERISATION OF THE BEHAVIOUR OF BEAM-TO-COLUMN STEEL JOINTS UP TO FAILURE. The Hong Kong Institute of Steel Construction, 2022. http://dx.doi.org/10.18057/ijasc.2022.18.3.5.

Full text
Abstract:
The design of steel joints is currently dealt with in Eurocode 3 through the well-known “component method”. In particular, Part 1-8 of this standard provides guidance on how to apply the method to a wide range of joint configurations allowing to assess the latter’s initial rotational stiffness and resistance. Nonetheless, whenever a global structural plastic analysis is contemplated, provisions of Eurocode 3 are insufficient since no clear guidance on how to determine the ultimate resistance and the ultimate rotation capacity of joints is provided. In this paper, the full-range behaviour of be
APA, Harvard, Vancouver, ISO, and other styles
9

NUMERICAL ANALYSIS AND EVALUATION OF EFFECTIVE SLAB WIDTH OF COMPOSITE CONTINUOUS BEAMS WITH SEMI-RIGID JOINT. The Hong Kong Institute of Steel Construction, 2021. http://dx.doi.org/10.18057/ijasc.2021.17.4.1.

Full text
Abstract:
The characterization of the structural behavior of composite beams is directly affected by the determination of the effective slab width. Various codes propose their own definitions of the effective width based on the beam span and the slab width parameters. However, the evaluation of the effective width may be influenced by other parameters. The aim of this work is to determine the most important factors affecting effective width for continuous composite beams with semi-rigid joints using numerical simulations. A three-dimensional finite element model of a composite continuous beam using expl
APA, Harvard, Vancouver, ISO, and other styles
10

SIMPLIFIED MODELLING OF NOVEL NON-WELDED JOINTS FOR MODULAR STEEL BUILDINGS. The Hong Kong Institute of Steel Construction, 2021. http://dx.doi.org/10.18057/ijasc.2021.17.4.10.

Full text
Abstract:
Prefabricated modular steel (PFMS) construction is a more efficient and safe method of constructing a high-quality building with less waste material and labour dependency than traditional steel construction. It is indeed critical to have a precise and valuable intermodular joining system that allows for efficient load transfer, safe handling, and optimal use of modular units' strength. Thus, the purpose of this study was to develop joints using tension bolts and solid tenons welded into the gusset plate (GP). These joints ensured rigid and secure connectivity in both horizontal and vertical di
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!