1

Zhang, Zhigang, and Xiaoqing Xu. "Static and Fatigue Behavior of Rubber-Sleeved Stud Shear Connectors as Part of Field-Cast Ultra-High Performance Concrete Connections." Materials 13, no. 10 (2020): 2269. http://dx.doi.org/10.3390/ma13102269.

Full text
Abstract:
Field-cast ultra-high performance concrete (UHPC) connections are an innovative and prospective solution for combining full-depth precast concrete decks and steel girders. However, previous studies show that the slip capacity of stud shear connectors embedded in UHPC cannot meet the requirements for ductile connectors by Eurocode 4, which can reduce the resistance of steel and concrete composite members. In this study, the rubber-sleeved stud shear connector, which is a composite of ordinary stud and rubber sleeve, was adopted for the field-cast UHPC connections. Push-out tests were conducted
APA, Harvard, Vancouver, ISO, and other styles
2

Kocatas, Alper Tolga, and Ali Hikmet Dogru. "Enhancing UML Connectors with Behavioral ALF Specifications for Exogenous Coordination of Software Components." Applied Sciences 13, no. 1 (2023): 643. http://dx.doi.org/10.3390/app13010643.

Full text
Abstract:
Connectors are powerful architectural elements that allow the specification of interactions between software components. Since the connectors do not include behavior in UML, the components include the behavior for coordinating the components, complicating the designs of components and decreasing their reusability. In this study, we propose the enrichment of UML connectors with behavioral specifications. The goal is to provide separation of concerns for the components so that they are freed from coordination duties. The reusability of the components will increase as a result of such exogenous c
APA, Harvard, Vancouver, ISO, and other styles
3

Farid, Boursas, and Djamel Boutagouga. "Parametric study of I-shaped shear connectors with different orientations in push-out test." Frattura ed Integrità Strutturale 15, no. 57 (2021): 24–39. http://dx.doi.org/10.3221/igf-esis.57.03.

Full text
Abstract:
A great deal of research has been conducted to improve the understanding of the behavior of new types of shear connectors. This article presents the study of I-shaped connectors behavior under monotonic load welded in four different orientations in order to get the position which gives the high shear strength and the best ductility. For this purpose, eight push-out test specimens with I-shaped shear connectors with different orientations and dimensions were tested in C20/25 and C30/37 concrete classes. The load-slip behavior and failure modes of the tested connectors are presented and discusse
APA, Harvard, Vancouver, ISO, and other styles
4

Larrañaga Rubio, Sherley, and Maritzabel Molina Herrera. "Grade-two resistance screw shear connector behavior for a 28 MPa concrete section." Ingeniería e Investigación 27, no. 2 (2007): 18–25. http://dx.doi.org/10.15446/ing.investig.v27n2.14825.

Full text
Abstract:
Screw shear connectors are being more commonly used in compound concrete sections in Colombia; however, they have been designed in line with Colombian Seismic-Resistant Standards (NSR-98) rather than those established for stud shear connectors. This work represents a starting point for analysing screw shear connector behavior. 54 specimens were made for the experiment, consisting of a metallic profile and two concretes slabs where the connectors were embedded. 1/2” (12.7mm), 5/8” (15.9mm) and 3/4” (19.1mm) diameter screws were used and placed at different distances. The push-out test was used
APA, Harvard, Vancouver, ISO, and other styles
5

Chen, Dong, Kuaikuai Li, Zhiyang Yuan, Baoquan Cheng, and Xing Kang. "Shear Behavior of FRP Connectors in Precast Sandwich Insulation Wall Panels." Buildings 12, no. 8 (2022): 1095. http://dx.doi.org/10.3390/buildings12081095.

Full text
Abstract:
Glass fiber reinforced polymer (FRP) composite connectors used in precast sandwich insulation wall panels directly affect the safety of the wall. In practical applications, a precast concrete sandwich insulation wall panel is transported to the construction site for hoisting 3–5 days after steam curing, and its concrete strength typically reaches approximately 70% of the design strength (i.e., the concrete strength after natural curing for 14 days). This study investigated the natural curing of concrete for 14 days and analyzed the mechanical properties of FRP connectors with two different sec
APA, Harvard, Vancouver, ISO, and other styles
6

Mohanan, Revathy. "STATIC BEHAVIOR OF DIFFERENT SHEAR CONNECTORS OF COMPOSITE SLAB USING ANSYS." International Scientific Journal of Engineering and Management 04, no. 06 (2025): 1–9. https://doi.org/10.55041/isjem04487.

Full text
Abstract:
Abstract - Headed stud shear connectors are commonly used to transfer longitudinal shear forces across the steel-concrete interface. In the areas of high shear, many studs should be welded to the top flanges to provide full shear connection in terms of strength. However, this causes long welding time, raise safety concerns, and also makes it difficult to remove a deteriorated concrete slab, which may damage. In this study, the static behaviour of Channelled, Tee, and Spiral shear connectors used in composite steel concrete beams was analytically examined using ANSYS. Ten specimens were modelle
APA, Harvard, Vancouver, ISO, and other styles
7

K. Ali, Ola, Amer M. Ibrahim, Abbas Hatif naji, and Ibrahim A. Ali. "Shear Connectors Behavior Under Elevated Temperature: A review." Bilad Alrafidain Journal for Engineering Science and Technology 3, no. 2 (2024): 134–53. http://dx.doi.org/10.56990/bajest/2024.030210.

Full text
Abstract:
A composite member is described as a structural steel shape that has been built up or rolled and filled with concrete, covered in reinforced concrete, or structurally attached to a slab of reinforced concrete. The shear connection between the steel beam and the concrete slab is the primary component of the composite beam. In risky situations, like building fires, the performance of a composite structures and steel structures are heavily dependent on the execution of connection. Numerous kinds of shear connectors exist and being utilized in the construction engineering rendering to their use. T
APA, Harvard, Vancouver, ISO, and other styles
8

Liu, Xia, Xin Wang, Tan Yang, and Zhishen Wu. "The Shear Behavior of Insulated Precast Concrete Sandwich Panels Reinforced with BFRP." Buildings 12, no. 9 (2022): 1326. http://dx.doi.org/10.3390/buildings12091326.

Full text
Abstract:
Typical insulated precast concrete sandwich panel (PCSP) systems are composed of two concrete wythes separated by a layer of insulation. The structural behavior of insulated PCSP systems heavily depends on elements between two wythes known as connectors, which ensure they work as a whole. Double shear tests were carried out on 58 insulated PCSP specimens reinforced with basalt fiber-reinforced polymer (BFRP) connectors; failure modes, load displacement curves and bearing capacity of BFRP connectors were obtained. Effects of diameter, insulation thickness, installation angle, layout spacing and
APA, Harvard, Vancouver, ISO, and other styles
9

Xue, Guofeng, Wei Bao, Jin Jiang, and Yongsong Shao. "Hysteretic Behavior of Beam-to-Column Joints with Cast Steel Connectors." Shock and Vibration 2019 (November 29, 2019): 1–20. http://dx.doi.org/10.1155/2019/9802672.

Full text
Abstract:
This study proposed a beam-to-column joint equipped with a new type of cast steel connector. The cast steel connector concentrated the primary portion of the deformation and energy dissipation of the joint and was installed with full bolted connections, rendering it a replaceable energy dissipation component and facilitating the rapid repair of the joint after an earthquake. Three full-scale specimens were fabricated and tested to investigate the hysteretic behaviors of the proposed joints under cyclic loadings. The results showed that the proposed cast steel connector exhibited reliable ducti
APA, Harvard, Vancouver, ISO, and other styles
10

Guo, Jiangran, Qingxuan Shi, Ge Ma, and Tengfei Li. "Shear Behavior of Superposed Perfobond Connectors Considering Lateral Constraints." Applied Sciences 12, no. 6 (2022): 3162. http://dx.doi.org/10.3390/app12063162.

Full text
Abstract:
Superposed perfobond connectors are a type of connector used in composite structures. When the construction conditions are limited to increase the diameter of the opening, the shear capacity of the connector can be improved by enhancing the confining effect of the concrete dowel. In this study, 12 superposed perfobond connectors were fabricated to investigate the influence of lateral constraints on their shear behavior. The effects of hole area and holes’ number, diameter of the perforating rebar, concrete compressive strength, and the number of transverse reinforcements were investigated via
APA, Harvard, Vancouver, ISO, and other styles
11

Wang, Xizhi, Yuqing Liu, and Yangqing Liu. "Experimental study on shear behavior of notched long-hole perfobond connectors." Advances in Structural Engineering 22, no. 1 (2018): 202–13. http://dx.doi.org/10.1177/1369433218782991.

Full text
Abstract:
It is restricted in applying perfobond connectors in steel-concrete composite bridges with shallow rib heights or narrow connector distances, because it is unfavorable to enhance shear connection by enlarging hole diameter of perfobond connectors and difficult to install transverse rebars in perforated holes. To address this issue, an alternative perfobond connector was proposed by making a notch on the outer edge of the lengthened circular hole in this paper. To investigate the differences of failure mode, shear strength, slip behavior, and load transferring mechanism between circular-hole an
APA, Harvard, Vancouver, ISO, and other styles
12

Zhang, Chikun, Kewei Ding, and Shulin He. "Seismic Performance of Panel Connectors with Steel Frame Based on Autoclaved Lightweight Concrete (ALC)." Buildings 12, no. 3 (2022): 372. http://dx.doi.org/10.3390/buildings12030372.

Full text
Abstract:
This paper proposes new prefabricated autoclaved lightweight concrete (ALC) connectors which allow limited sliding. The seismic performance of the proposed connectors and a traditional connector (L-hooked bolt) were investigated in depth. Three specimens of full-scale steel frames with ALC panel and connectors were subjected to horizontal low-cyclic loading. The failure modes, hysteretic behavior, strength and deterioration of stiffness and energy-dissipating performance of all specimens were analyzed and discussed. The experimental results indicated that the frames of the new connectors were
APA, Harvard, Vancouver, ISO, and other styles
13

Silva, John Kennedy Fonsêca, and Rodrigo de Melo Lameiras. "Experimental Analysis of the Mechanical Behavior of Shear Connectors for Precast Sandwich Wall Panels When Subjected to the Push-Out Tests." Buildings 14, no. 10 (2024): 3246. http://dx.doi.org/10.3390/buildings14103246.

Full text
Abstract:
Precast concrete sandwich panels consist of two outer layers connected by a central connector and an inner insulating layer that enhances thermal and acoustic performance. A key challenge with these panels is eliminating thermal bridges caused by metallic connectors, which reduce energy efficiency. PERFOFRP connectors, made from perforated glass fiber-reinforced polymer (GFRP) sheets, have been proposed to address this issue. These connectors feature holes that allow concrete to pass through, creating anchoring pins that enhance shear resistance and prevent the separation of the concrete layer
APA, Harvard, Vancouver, ISO, and other styles
14

ALMAYYAHI, Mohammed Noori Salman, Abdulnasser Aabbas, and Haleem Hussain. "Effects of Recycled Concrete on Structural Behavior of Composite Beams with Y-Rib Shear Connectors." Misan Journal of Engineering Sciences 2, no. 1 (2023): 53–97. http://dx.doi.org/10.61263/mjes.v2i1.44.

Full text
Abstract:
This study inspects the structural behavior of composite steel concrete beams connected together by Y-Rib shear connectors using recycled concrete. The main method involves using stud shear connectors with normal concrete. By comparing the structural performance of Y-Rib shear connectors with conventional stud shear connectors, the study aims to determine the benefit of using this type of connector with recycled concrete. Improved results in terms of maximum load-bearing capacity before failure and maintaining structural integrity until failure would indicate a viable solution to the sliding i
APA, Harvard, Vancouver, ISO, and other styles
15

BARBOSA, W. C. S., L. M. BEZERRA, L. CHATER, and O. R. O. CAVALCANTE. "Experimental evaluation on the structural behavior of truss shear connectors in composite steel-concrete beams." Revista IBRACON de Estruturas e Materiais 12, no. 5 (2019): 1157–82. http://dx.doi.org/10.1590/s1983-41952019000500010.

Full text
Abstract:
Abstract The composite structures have great advantages in terms of structural and constructive aspects, with the shear connectors being decisive for obtaining the interaction between the structural elements and for the distribution of the stresses in the structure, taking advantage of the potentiality of each constituent material of the composite structure (steel and concrete). This work, through experimental studies, presents the development of a shear connector (Truss connector) proposed for use in a concrete-steel composite beam. The proposed connector is easy to implement and can serve as
APA, Harvard, Vancouver, ISO, and other styles
16

Rin, Tran Van, Nguyen Minh Hai, and Phan Hoang Nam. "Analytical study on flexural behavior of steel composite girder using truss element for shear connectors with different types and layouts." IOP Conference Series: Materials Science and Engineering 1289, no. 1 (2023): 012007. http://dx.doi.org/10.1088/1757-899x/1289/1/012007.

Full text
Abstract:
Abstract The key to improve the accuracy of behavior analysis of the steel composite girder lies in the reasonable modelling the intergration between the reinforced concrete slab and the steel girder. Based on design requirements and construction methods, the type and layout of the shear connectors between the concrete slab and the steel girder are different, significantly affecting the behavior of the composite girder. This study is conducted to (i) investigate the applicability of a truss element available in the popular simulation software Abaqus in modelling the shear connectors of composi
APA, Harvard, Vancouver, ISO, and other styles
17

Duan, Linli, Xin Nie, Han Su, and Jike Tan. "Seismic Response Analysis of Steel–Concrete Composite Frame Structures with URSP Connectors." Materials 15, no. 23 (2022): 8655. http://dx.doi.org/10.3390/ma15238655.

Full text
Abstract:
The uplift-restricted and slip-permitted (URSP) connector is a new type of connector used in steel–concrete composite structures that has been proven to improve the structural performance of negative moment regions. Since this connector changes the interface restraint between the slab and steel beam, there is an imperative to study the seismic performance of steel–concrete composite frame systems with this new type of connector. In this study, the dynamic behavior of composite frame structures with URSP connectors under seismic loads was numerically investigated. First, a beam–shell mixed mode
APA, Harvard, Vancouver, ISO, and other styles
18

Akram, Mostafa Humayun, Md Rabiul Alam, Md Naimul Haque, and Md Tanzim Hossain. "EVALUATING THE STRUCTURAL EFFICACY OF ANGLE AND CHANNEL SHEAR CONNECTORS IN BRICK AGGREGATE CONCRETE AND STONE AGGREGATE CONCRETE AND COMPARISON." Malaysian Journal of Civil Engineering 36, no. 2 (2024): 69–79. http://dx.doi.org/10.11113/mjce.v36.22331.

Full text
Abstract:
Composite structure is becoming prominent for its economy, less time consumption, and higher stiffness-mass ratio. Composite action of the steel-concrete composite structure mainly depends on the connector's geometry and materials. Proper choice of shear connector could make steel beam and concrete slab cross-section minimal. This study carries out push-out tests to evaluate the structural efficiency of channel and angle shear connectors in brick aggregate concrete and stone aggregate concrete. It specifically looks at the failure mode, ductility, load-slip behavior, and energy absorption capa
APA, Harvard, Vancouver, ISO, and other styles
19

Cui, Jianhua, Shulin He, Kewei Ding, Yu Zhang, and Xiaoying Kong. "Cyclic Behavior of Autoclaved Aerated Concrete External Panel with New Connector." Materials 15, no. 24 (2022): 8778. http://dx.doi.org/10.3390/ma15248778.

Full text
Abstract:
In this paper, a new slip-type crossing connector is proposed for autoclaved aerated concrete (ALC) panels with steel frames, and the proposed connector is also studied deeply in terms of seismic performance. The research included pseudo-static tests and finite element simulations. First, the seismic performance of slip-type crossing connectors and standard L-hooked bolts was studied comparatively, including the stability, bearing capacity, stiffness, energy dissipation, and hysteresis performance. ABAQUS 2020 software was used to establish finite element models, and the results of the experim
APA, Harvard, Vancouver, ISO, and other styles
20

Saggaff, Anis, Talal Alhajri, M. Md Tahir, et al. "Experimental and Analytical Study of Various Shear Connectors Used for Cold-Formed Steel-Ferrocement Composite Beam." Applied Mechanics and Materials 754-755 (April 2015): 315–19. http://dx.doi.org/10.4028/www.scientific.net/amm.754-755.315.

Full text
Abstract:
This work presents the experimental tests carried out to evaluate the behaviour of different types of shear connectors proposed for cold formed steel (CFS) section integrated with ferrocement slab as potential used for composite beam. Ten push-out test specimens of cold-formed steel lipped channel sections connected with ferrocement slab were tested. Three types of shear connectors were studied comprised of bolts, self-drilling-screw and bar angle. The connection behavior is analysed in terms of its load-slip relationship and the failure mode. The parametric studies were performed to investiga
APA, Harvard, Vancouver, ISO, and other styles
21

Milićević, Ivan, Branko Milosavljević, and Milan Spremić. "Behavior of Demountable Connections with Taper Threaded Mechanical Coupler (TTC) and Rebar Anchor Under Tension Load." Buildings 15, no. 6 (2025): 928. https://doi.org/10.3390/buildings15060928.

Full text
Abstract:
Composite and mixed steel-concrete buildings, apart from high structural efficiency, have great potential in terms of reuse of structural elements at the end of the life of the buildings. The use of most demountable connectors can assure the reuse of steel elements; however, the reuse of reinforced concrete (RC) elements and embedded connectors remains relatively uncertain due to potential damage of connectors during disassembly. One of the possible solutions to assure the reuse of all components could be to use demountable connectors assembled from a demountable bolt and an embedded mechanica
APA, Harvard, Vancouver, ISO, and other styles
22

Nouri, Karim, Nor Hafizah Ramli Sulong, Zainah Ibrahim, Mohammad Bazzaz, and H. Elhosiny Ali. "Finite Element Analysis of Novel Stiffened Angle Shear Connectors at Ambient and Elevated Temperature." Sustainability 15, no. 1 (2022): 184. http://dx.doi.org/10.3390/su15010184.

Full text
Abstract:
This is a numerical study to investigate the behavior of novel stiffened angle shear connectors embedded in solid concrete slabs at both ambient and elevated temperatures. An advanced nonlinear finite element model is developed and validated with available experimental work by Nouri, K., et al. 2021. Additionally, parametric studies are performed to evaluate the variations in concrete strength and the connector’s dimensions. The results indicate that the ultimate strength of the stiffened angle shear connector drops by 92% in 1050 °C. Comparing studies show the strength of the stiffened shear
APA, Harvard, Vancouver, ISO, and other styles
23

Zeng, Xinggui, Shao-Fei Jiang, and Donghua Zhou. "Effect of Shear Connector Layout on the Behavior of Steel-Concrete Composite Beams with Interface Slip." Applied Sciences 9, no. 1 (2019): 207. http://dx.doi.org/10.3390/app9010207.

Full text
Abstract:
In a steel-concrete composite beam (hereafter referred to as a composite beam), partial interaction between the concrete slab and the steel beam results in an appreciable increase in the beam deflections relative to full interaction behavior. Moreover, the distribution type of the shear connectors has a great impact on the degree of the composite action between the two components of the beam. To reveal the effect of shear connector layout in the performance of composite beams, on the basis of a developed one-dimensional composite beam element validated by the closed-form precision solutions an
APA, Harvard, Vancouver, ISO, and other styles
24

M. Al-Khekany, Alaa, Labeeb S. Al-Yassri, Munaf A. Al-Ramahee, and Saeed Abdul-Abbas. "Effect of Angle Shear Connectors on the Behavior of Composite Concrete Steel Flexural Members Under Negative Moment." International Journal of Engineering & Technology 7, no. 4.20 (2018): 174. http://dx.doi.org/10.14419/ijet.v7i4.20.25921.

Full text
Abstract:
This research presents an experimental program to study the effect of using angle shear connectors instead of the headed stud on the flexural behavior of composite beams under negative bending moment (NBM). Both the angle and headed stud shear connectors used in this study have the same cross-sectional area. Five composite beams were casted and tested using three-point load configuration to ensure the NBM effect. Different parameters were included in this study such as the type of shear connector, bond interaction (partial and complete bond interaction) and arrangement of angle shear connector
APA, Harvard, Vancouver, ISO, and other styles
25

Si, Xiu Yong, Jian Bo Zhao, and Xiang Zhong Bai. "Mechanical Properties Research of Steel-Concrete Composite Structure's Connector." Advanced Materials Research 738 (August 2013): 128–32. http://dx.doi.org/10.4028/www.scientific.net/amr.738.128.

Full text
Abstract:
A new type of PBL shear connector gets more attention with the rapid development of steel-concrete composite structure. The PBL shear connector's static behavior and influence factors thereof are analysed through experiments. The PBL shear connector's force-transmission mechanism is discussed. The conclusions show that the thickness of perforate plate has significant impact of PBL shear connectors design bearing capacity, shear stiffness and ultimate bearing capacity. According to the thickness of perforate plate, the failure mode of PBL shear connector may appear to flexural and shear failure
APA, Harvard, Vancouver, ISO, and other styles
26

Zhi, Qing, and Zhengxing Guo. "Experimental evaluation of precast concrete sandwich wall panels with steel–glass fiber–reinforced polymer shear connectors." Advances in Structural Engineering 20, no. 10 (2017): 1476–92. http://dx.doi.org/10.1177/1369433216683198.

Full text
Abstract:
A new shear connector is proposed in this article. The shear connector is made of steel–glass fiber–reinforced polymer material. Twelve full-scale precast insulated concrete sandwich panels were tested under flexure to analyze their flexural behavior subjected to pressure. The test program was composed of eight sandwich panels with steel–glass fiber–reinforced polymer connectors and four panels for comparison that were panels using stainless steel truss connectors, pure glass fiber–reinforced polymer pin connectors, and no connectors, respectively. Their load–deflection relationships, load–sli
APA, Harvard, Vancouver, ISO, and other styles
27

Shariati, Mahdi, Nor Hafizah Ramli Sulong, Hamid Sinaei, Mohammad Mehdi Arabnejad Khanouki, and Payam Shafigh. "Behavior of Channel Shear Connectors in Normal and Light Weight Aggregate Concrete (Experimental and Analytical Study)." Advanced Materials Research 168-170 (December 2010): 2303–7. http://dx.doi.org/10.4028/www.scientific.net/amr.168-170.2303.

Full text
Abstract:
This paper describes five push-out tests carried out at the University of Malaya using channel shear connector. The tests study experimentally and analytically, the behavior of channel shear connectors embedded in normal and light weight aggregate concrete (LWAC). Limited push-out tests are used to measure the accuracy of a proposed nonlinear finite element model for typical push-out test specimens. Using this model, an extensive parametric study performed to arrive at prediction for shear capacity of channel connectors in LWAC. An equation is suggested for the shear capacity of these connecto
APA, Harvard, Vancouver, ISO, and other styles
28

Ye, Xin, Bo Shan, Qian Yue, and Zhenyu Wang. "Long-term behavior of connections for glubam-concrete composite beams." MATEC Web of Conferences 275 (2019): 01001. http://dx.doi.org/10.1051/matecconf/201927501001.

Full text
Abstract:
Glubam-concrete composite (BCC) structure is a construction technique where glue-laminated bamboo beam is connected to an upper concrete slab using different types of connectors. The long-term behavior and creep mechanism of BCC system are very complex due to different time-dependent behavior of three components. This paper performed a series long-term push-out tests on four types of connections under static load. The tests lasted for a period of seven months in uncontrolled sheltered indoor condition. Important results such as the relative slip-time curves are presented in order to characteri
APA, Harvard, Vancouver, ISO, and other styles
29

Abdi, Rochdi El, Erwann Carvou, Noureddine Benjemâa, and El Mostafa Zindine. "Power Connector Behavior Used in Automotive Applications." Applied Mechanics and Materials 325-326 (June 2013): 556–61. http://dx.doi.org/10.4028/www.scientific.net/amm.325-326.556.

Full text
Abstract:
The increase in the number of electronic and electric systems used in the automotive industry necessitates a high level of electric power. To respond to this high electric power demand, it will be necessary to increase the voltage of the batteries and the current and to use new power connectors. A connector provides a separable interface between two subsystems of an electronic system. The main function of the connector is to transmit a signal or distribute power. For power connectors, heating can lead to an increase in contact resistance and sometimes even to contact surface melting and thus t
APA, Harvard, Vancouver, ISO, and other styles
30

Ren, Libing, Xiaofei Zhang, and Xuke Lan. "Research on the Mechanism and Dynamic Characteristics of Intermittent Failure of Electrical Connectors." Applied Sciences 15, no. 6 (2025): 3328. https://doi.org/10.3390/app15063328.

Full text
Abstract:
Aging or damaged electrical connectors always suffer intermittent failures (IFs) during operation. Because there are few quantitative studies on electrical connector intermittent failure mechanisms, the intermittent failures of electrical connectors are difficult to isolate. Therefore, the mechanism and dynamic characteristics of intermittent failure is studied in this paper. Firstly, the degradation process of an electrical connector is analyzed. Secondly, according to electrical contact model, the intermittent failure mechanism caused by vibration is studied. Thirdly, to make a profound stud
APA, Harvard, Vancouver, ISO, and other styles
31

Alemayehu, Robel Wondimu, Jaehoon Bae, Young K. Ju, and Min Jae Park. "Bond Behavior of Concrete-Filled Steel Tube Mega Columns with Different Connectors." Materials 15, no. 8 (2022): 2791. http://dx.doi.org/10.3390/ma15082791.

Full text
Abstract:
Concrete-filled steel tubes (CFSTs) are widely used in construction. To achieve composite action and take full advantage of the two materials, strain continuity at the steel–concrete interface is essential. When the concrete core and steel tube are not loaded simultaneously in regions such as beam or brace connections to the steel tubes of a CFST column, the steel–concrete bond plays a crucial role in load transfer. This study uses a validated finite-element model to investigate the bond-slip behavior between the steel tube and concrete in square CFST mega columns through a push-out analysis o
APA, Harvard, Vancouver, ISO, and other styles
32

Luo, Yan Yan, Li Xin Wang, Ke Li, et al. "Effect of Temperature Cycling on Stress Relaxation Behavior of Electrical Connector Contacts." Applied Mechanics and Materials 492 (January 2014): 86–89. http://dx.doi.org/10.4028/www.scientific.net/amm.492.86.

Full text
Abstract:
This paper mainly studies the effect of temperature cycling on stress relaxation behavior of contacts for electrical connectors. Based on the analysis of the test specifications of electrical connectors, this paper provides a kind of test method on stress relaxation behavior of electrical connector contacts under temperature cycling conditions. The detecting circuit is designed; the test is carried out and finally, according to the test data, it can be concluded that 1) for the same temperature change, the absolute change of strain within the temperatures above zero is bigger than that within
APA, Harvard, Vancouver, ISO, and other styles
33

Vahedi, Masood, Hamed Ebrahimian, and Ahmad M. Itani. "Full-Scale Testing and Analytical Modeling of Rebar Cages Reinforced with Mechanical U-Bolt Connectors." Applied Sciences 13, no. 14 (2023): 8113. http://dx.doi.org/10.3390/app13148113.

Full text
Abstract:
Rebar cages are the skeletons of reinforced concrete structures. These temporary structures consist of longitudinal and transverse reinforcing bars connected by tie-wires. Given the relatively low strength of tie-wire connections, replacing tie-wires with mechanical connectors such as U-bolts can improve the stability and strength of rebar cages. This paper aims to understand the behavior of large prefabricated rebar cages reinforced with mechanical U-bolt connectors through experimental and analytical investigations. Twenty-six full-scale experimental tests are performed on five different und
APA, Harvard, Vancouver, ISO, and other styles
34

Alhassankoo, Yousif Th, Suhaib Y. Al-Darzi, and Kaythar A. Ibrahim. "Investigating The Behavior of Steel-Concrete Composite Arch Beam with Different Types of Shear Connectors." Tikrit Journal of Engineering Sciences 31, no. 3 (2024): 233–45. http://dx.doi.org/10.25130/tjes.31.3.22.

Full text
Abstract:
Composite steel-concrete arch beams are used in civil engineering. The effect of the shear connector type on the behavior of this type of beam was to act as the first parameter in this study. The test used four types of shear connectors: stud, angle, perfobond, and rebar. The second parameter involved two composite section types: steel I-section-concrete composite arch members (SICM) and steel plate-concrete composite arch members (SPCM). A total of eight samples were prepared in two groups. The first used the SICM and four connector types to get four samples: stud (SI), angle (AI), perfobond
APA, Harvard, Vancouver, ISO, and other styles
35

ROESLER, CARLOS RODRIGO DE MELLO, RÔMULO PEDROZA PINHEIRO, ANDRÉ LUÍS ALMEIDA PIZZOLATTI, VALERIA ROMERO, and HELTON LUIZ APARECIDO DEFINO. "IN VITRO MECHANICAL EVALUATION OF SPINAL FIXATION ROD CONNECTORS." Coluna/Columna 20, no. 3 (2021): 156–60. http://dx.doi.org/10.1590/s1808-185120212003245449.

Full text
Abstract:
ABSTRACT Objective Evaluate and compare the mechanical resistance and the fatigue behavior associated with the use of three different modalities of vertebral fixation system rod connectors through in vitro pre-clinical mechanical tests developed specifically for this application (linear, lateral with square connector and lateral with oblique connector). Methods Cobalt chromium rods 5.5 mm in diameter were used and coupled with three types of connectors: a) side rod with oblique connector, b) side rod with square connector, and c) rod and linear connectors. Quasi-static mechanical four-point be
APA, Harvard, Vancouver, ISO, and other styles
36

Xue, Chengfeng, Hao Huang, and Qing Jia. "Shear Mechanism of a Novel SFCBs-Reinforced Composite Shear Connector: Experimental, Theoretical Investigations and Numerical Model." Materials 17, no. 14 (2024): 3508. http://dx.doi.org/10.3390/ma17143508.

Full text
Abstract:
Traditional stud and perfobond leiste (PBL) shear connectors are commonly used as load-transferring components in steel-concrete composite structures. Composite shear connectors fully utilize the advantages of traditional stud and PBL shear connectors. In order to maximize the advantages of composite shear connectors, a novel shear connector for complex environments was proposed. The steel-FRP composite bars (SFCBs) with excellent fatigue resistance and corrosion resistance were introduced to replace the steel bars. This study discussed the failure modes, load–slip curves, and load–strain curv
APA, Harvard, Vancouver, ISO, and other styles
37

He, Yuliang, Junjie Li, Wujian He, Qiangqiang Wu, Yiqiang Xiang, and Ying Yang. "Static Behavior of Post-Installed High-Strength Large-Bolt Shear Connector with Fabricated Hybrid Fiber-Reinforced Concrete/Ordinary Concrete Deck." Materials 18, no. 5 (2025): 1091. https://doi.org/10.3390/ma18051091.

Full text
Abstract:
Recent research indicates that high-strength bolts could be more effectively and efficiently used to connect steel girders and fabricated decks or retrofit existing composite girders than headed studs. To reduce the number of bolt shear connectors and, thus, further accelerate the construction of composite girders, high-strength large bolts could be an excellent alternative, resulting in greater concrete stress below the bolt. Also, hybrid fiber-reinforced concrete (HFRC) has better tensile ductility and strength than that of ordinary concrete (OC). Therefore, this study tried to design eighte
APA, Harvard, Vancouver, ISO, and other styles
38

Lee, Jun-Seop, Jong-Hun Woo, Kyung-Jae Shin, and Hee-Du Lee. "Design Methodology of U-Shaped Infilled Composite Beams with Angled Shear Connectors Using Finite Element Analysis." Buildings 13, no. 9 (2023): 2221. http://dx.doi.org/10.3390/buildings13092221.

Full text
Abstract:
A composite beam is a structural member that behaves as a single unit by using shear connectors between a concrete slab and an I-shaped steel girder. The composite ratio is crucial and is determined by the shear connectors’ ability to withstand the horizontal shear forces between the concrete and steel girder. In this study, a U-shaped composite beam was designed, which differs from conventional composite beams as it allows the use of a steel girder as a formwork. Moreover, angle-type shear connectors, instead of stud-type connectors, were employed. Based on this design, large-scale U-shaped c
APA, Harvard, Vancouver, ISO, and other styles
39

Yu, Qiong, Liang Zhang, Shaohua Bai, Baoxiu Fan, Zhenhai Chen, and Ling-Zhi Li. "Experimental Study on Seismic Behavior of Precast Frame Columns with Vertical Reinforcement Spliced with Grouted Sleeve Lapping Connectors." Advances in Civil Engineering 2021 (October 8, 2021): 1–21. http://dx.doi.org/10.1155/2021/1549303.

Full text
Abstract:
Grouted splice connector is widely employed in precast concrete structures, but its utilization is still limited by shortcomings such as high construction cost, inconvenience in assemblage, and uncompacted grout caused by its small sleeve diameter. The grouted sleeve lapping connectors proposed by the authors can not only provide reasonable force transfer and convenient construction processing but also have the characteristics of low price and easy grouting. In this paper, the seismic performance of two full-scale precast concrete columns with two types of grouted sleeve lapping connectors was
APA, Harvard, Vancouver, ISO, and other styles
40

Khorramian, Koosha, Shervin Maleki, Mahdi Shariati, and N. H. Ramli Sulong. "Behavior of Tilted Angle Shear Connectors." PLOS ONE 10, no. 12 (2015): e0144288. http://dx.doi.org/10.1371/journal.pone.0144288.

Full text
APA, Harvard, Vancouver, ISO, and other styles
41

Dai, Ning, Lanhao Cui, Yingpei Li, Liwei Fan, and Jiakun Chen. "A Numerical Simulation Study on the Out-of-Plane Performance of Timber Framework–Brick Wall Systems in Traditional Residential Buildings of Northern China." Buildings 14, no. 5 (2024): 1224. http://dx.doi.org/10.3390/buildings14051224.

Full text
Abstract:
To improve the out-of-plane collaborative performance of timber frames and walls, a metal connector is proposed and designed. A finite element model of the wall is established, and the composite block damage criteria and surface contact behavior are validated. Additionally, one group without metal connectors and three groups with different numbers of metal connectors placed at various positions in traditional residential wall models are established. Using static loading simulation, the influence of different numbers of metal connectors on the out-of-plane damage patterns, deformation character
APA, Harvard, Vancouver, ISO, and other styles
42

Al-Khateeb, Baha’a, Christopher Garcia, Mark P. Manning, Jon Mohle, and Yahya C. Kurama. "Seismic Precast Concrete Shear Walls with Short-Grouted Ductile Reinforcing Bar Connections." PCI Journal 70, no. 1 (2025): 58–83. https://doi.org/10.15554/pcij70.1-02.

Full text
Abstract:
This article presents results from the experimental testing of three precast concrete shear wall specimens that used nonproprietary, short-grouted corrugated steel straight duct connections for ductile energy-dissipating rein¬forcing bars crossing horizontal joints. In this type of connection, the energy-dissipation bars are terminated inside the connectors, and the bar forces are transferred into the precast concrete components through the design of vertical, transverse, and longitudinal tie reinforcing bars around the connectors. The performance of the specimens was evaluated against the sei
APA, Harvard, Vancouver, ISO, and other styles
43

Apriyono, Arwan, Sumiyanto Sumiyanto, Yanto Yanto, Sachrul Iswahyudi, and Rino Wahyu Pamungkas. "Analysis of Different Stripe Connectors for a Gabion Wall based on Woven Waste Tire Stripes." Civil Engineering Dimension 21, no. 2 (2019): 66–69. http://dx.doi.org/10.9744/ced.21.2.66-69.

Full text
Abstract:
In this research, woven waste tire stripes are proposed as an alternative material to wire mesh to make a gabion wall. The performance of the waste tire stripe-based gabion wall is highly dependent on the strength of its stripe, where the stripe connector plays an important role. This research aims to inspect the behavior of different stripe connectors for the gabion wall. To achieve this, a physical model was built and employed to test the strength of the gabion wall. Various stripe connectors are used; adhesive rubber glue, one inch nail, and two mm wire. The strength capacity of the models
APA, Harvard, Vancouver, ISO, and other styles
44

Tonkikh, Gennadiy, and Denis Chesnokov. "A new design proposal for composite beams with powder actuated shear connectors." E3S Web of Conferences 410 (2023): 02034. http://dx.doi.org/10.1051/e3sconf/202341002034.

Full text
Abstract:
This paper introduces a proposal for the SP 266.1325800 code update, which is applied as a national building code for composite structure design in Russian and some CIS countries. The proposal is based on deep codes analyze and comparison and previous authors’ publications. The research is dedicated to nailed shear connectors’ behavior in composite beams with profiled sheeting. The proposal provides a less conservative approach for composite beams with ductile shear connectors and takes into account additional conditions, such as decking geometry and the structure’s performance under fire. The
APA, Harvard, Vancouver, ISO, and other styles
45

Boursas, Farid, Rafik Boufarh, and Abderrahmani Sifeddine. "EXPERIMENTAL INVESTIGATION ON THE SHEAR RESISTANCE OF I-SHAPED PERFORATED CONNECTORS IN COMPOSITE BEAMS." Architecture and Engineering 9, no. 3 (2024): 39–52. http://dx.doi.org/10.23968/2500-0055-2024-9-3-39-52.

Full text
Abstract:
Introduction: Steel-concrete composite girders have been widely used in bridges, with the stability of the interface being crucial. Shear connectors and reinforced concrete slabs play a key role as interfaces. Understanding the interaction between the composite beam and slab is essential for predicting the overall system response. It is necessary to optimize the connection between steel beams and reinforced concrete slabs in steel-concrete composite girders and facilitate their assembly and installation on-site, emphasizing their pivotal role in upholding the structural integrity of composite
APA, Harvard, Vancouver, ISO, and other styles
46

Li, Yifan, Yumo Wang, Yawen Zhong, Weisong Wei, He Su, and Tianyu Gao. "Finite Element Modeling of Beam-to-Column Steel Timber Composite Joints with Different Parameters." Buildings 14, no. 9 (2024): 2858. http://dx.doi.org/10.3390/buildings14092858.

Full text
Abstract:
This study presents a comprehensive three-dimensional finite element modeling and parametric analysis of composite beam-to-column joints in steel–timber composite structures. The investigation encompassed a variety of shear connector configurations, end plate designs, and bolt dimensions, aiming to elucidate their respective influences on the structural performance and behavior of these joints. Through meticulous numerical simulation, this research sought to enhance the understanding of the interactions and load transfer mechanisms within composite connections, thereby contributing to the opti
APA, Harvard, Vancouver, ISO, and other styles
47

Dewobroto, Wiryanto, Ika Bali, and Lodia Semaya Amnifu. "The compressive strength behavior of mahogany wood connections with bolt-ring connectors." IOP Conference Series: Materials Science and Engineering 852 (July 21, 2020): 012006. http://dx.doi.org/10.1088/1757-899x/852/1/012006.

Full text
APA, Harvard, Vancouver, ISO, and other styles
48

Zhu, Hongbing, Zhenghao Fu, Peng Liu, Yongcan Li, and Benlu Zhao. "Shear Behavior of Stud-PBL Composite Shear Connector for Steel–Ceramsite Concrete Composite Structure." Coatings 12, no. 5 (2022): 583. http://dx.doi.org/10.3390/coatings12050583.

Full text
Abstract:
For steel–concrete composite structure, a new type of stud–PBL composite shear connector can improve the shear resistance of steel–concrete interface, and polypropylene fiber ceramsite concrete can reduce the self-weight. Therefore, investigating the shear behavior of stud–PBL composite shear connectors for steel–ceramsite concrete composite structures bears significance. In this study, static testing and numerical simulation of the composite shear connector push-out specimen of polypropylene fiber ceramsite concrete were first conducted. The influencing factors of the shear bearing capacity w
APA, Harvard, Vancouver, ISO, and other styles
49

Zhu, Hongbing, Zhenghao Fu, Peng Liu, Yongcan Li, and Benlu Zhao. "Shear Behavior of Stud-PBL Composite Shear Connector for Steel–Ceramsite Concrete Composite Structure." Coatings 12, no. 5 (2022): 583. http://dx.doi.org/10.3390/coatings12050583.

Full text
Abstract:
For steel–concrete composite structure, a new type of stud–PBL composite shear connector can improve the shear resistance of steel–concrete interface, and polypropylene fiber ceramsite concrete can reduce the self-weight. Therefore, investigating the shear behavior of stud–PBL composite shear connectors for steel–ceramsite concrete composite structures bears significance. In this study, static testing and numerical simulation of the composite shear connector push-out specimen of polypropylene fiber ceramsite concrete were first conducted. The influencing factors of the shear bearing capacity w
APA, Harvard, Vancouver, ISO, and other styles
50

Al-Gasham, Thaar Saud Salman. "Experimental Behavior of Steel-Concrete-Steel Sandwich Beams with Truss Configuration of Shear Connectors." Journal of Engineering 22, no. 4 (2016): 18–29. http://dx.doi.org/10.31026/j.eng.2016.04.02.

Full text
Abstract:
This paper presents experimentally a new configuration of shear connector for Steel-Concrete-Steel (SCS) sandwich beams that is derived from truss configuration. It consists of vertical and inclined shear connectors welded together and to cover steel plates infilled with concrete. Nine simply supported SCS beams were tested until the failure under a concentrated central load (three- point bending). The beams were similar in length (1100mm), width (100mm), and the top plate thickness (4mm). The test parameters were; beam thickness (150, 200, 250, and 300mm), the bottom plate thickness (4, and 6
APA, Harvard, Vancouver, ISO, and other styles