Academic literature on the topic 'Behovsstöd'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Behovsstöd.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Dissertations / Theses on the topic "Behovsstöd"

1

Björlin, Johan. "En ansats till behovsstyrd applikationsutveckling." Thesis, Karlstads universitet, Fakulteten för ekonomi, kommunikation och IT, 2011. http://urn.kb.se/resolve?urn=urn:nbn:se:kau:diva-7642.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Lysén, Julia, and Evelina Lann. "Energieffektivisering av skolbyggnader geom behovsstyrd ventilation." Thesis, Linnéuniversitetet, Institutionen för teknik, TEK, 2011. http://urn.kb.se/resolve?urn=urn:nbn:se:lnu:diva-12084.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Blyh, Heidi, and Jonas Segerlund. "Effekten av digitala autonomistödjande textmeddelanden på deltagarnas behovstillfredsställelse, motivation till motion och motionsbeteende : en interventionsstudie." Thesis, Högskolan i Halmstad, Akademin för hälsa och välfärd, 2021. http://urn.kb.se/resolve?urn=urn:nbn:se:hh:diva-43811.

Full text
Abstract:
Baserat på Self-Determination Theory (SDT) och en randomiserad kontrollstudiedesign undersöktes effekten av autonomistödjande textmeddelanden i jämförelse med neutrala meddelanden eller inga meddelanden på deltagarnas behovstillfredsställelse, motivation, och aktivitetsnivå. Digital kvantitativ datainsamling användes där webbenkäterna skickades ut tre gånger till deltagarna, innan, under samt efter intervention. Totalt 107 frivilliga män och kvinnor svarade vid baslinjemätningen och delades sedan in i tre olika grupper, inaktiv kontrollgrupp (n = 45), aktiv kontrollgrupp (n = 29) samt interventionsgrupp (n = 33). Interventionen ägde rum i samband med en stegtävling. Textmeddelandena skickades ut till deltagarna i aktiva kontrollgruppen och interventionsgruppen två gånger varje vecka under åtta veckor, via en digital plattform. Det förelåg inga signifikanta skillnader mellan grupperna vid baslinjemätningen. En tvåvägs-ANOVA (repeated measure) visade att interventionen hade en signifikant effekt på upplevelsen av tillhörighet under interventionen. Dock förelåg inga andra signifikanta interventionseffekter. Det sammanlagda resultatet antyder således att den digitala interventionen, det vill säga att tillhandahålla deltagarna med autonomistödjande textmeddelanden, inte har någon bestående effekt på deltagarnas behovstillfredsställelse, motivation eller aktivitetsnivå.<br>Based on Self-Determination Theory (SDT) and a randomized controlled trial design, the effect of autonomy-supportive text messages was examined in comparison with neutral messages or no messages regarding the participants basic psychological needs, motivation and activity level. Digital quantitative data collection was used, and the web surveys were sent out three times to participants, pre, during and post intervention. A total of 107 male and female volunteers responded to the baseline measurement and were then divided into three different groups, inactive control group (n = 45), active control group (n = 29) and intervention group (n = 33). The intervention took place in relation to a step contest. Text messages were sent to the participant’s in the active control group and intervention group twice a week for a total of eight weeks, via a digital platform. There were no significant differences between the groups in the baseline measurement. A two-way ANOVA (repeated measure) showed that the intervention had a significant effect on the experience of relatedness during the intervention. However, there were no other significant intervention effects. The results suggest that the digital intervention, to provide participants with autonomy supportive text messages, does not have a lasting effect on need satisfaction, motivation or activity level.
APA, Harvard, Vancouver, ISO, and other styles
4

Ängalid, Filip. "Utredning av behovsstyrd ventilation : En jämförelse mellan CAV och VAV." Thesis, Högskolan i Gävle, Avdelningen för bygg- energi- och miljöteknik, 2012. http://urn.kb.se/resolve?urn=urn:nbn:se:hig:diva-13860.

Full text
Abstract:
Denna rapport är ett examensarbete på C-nivå som görs i sammarbete med teknikkonsulten Ramböll. Det vanligaste sättet att ventilera en byggnad idag är med så kallad CAV-ventilation (Constant Air Volume). Denna metod bygger på att ett luftflöde bestäms för rummet och upprätthålls med konstant flöde. En annan metod är så kallad VAV (Variable Air Volume) som bygger på att flödet varierar efter behovet. Anledningen till varför man väljer VAV istället för CAV är att med CAV finns det ofta en stor risk att man överventilerar ett rum eller byggnad, just på grund av att flödet är konstant. Problemet med VAV är att det är en högre investeringskostnad än för CAV så metoden lämpar sig bara där energibesparingen är så stor så den täcker mellanskillnaden i pris. Denna utredning visar i vilka typer av rum som det kan löna sig att installera VAV istället för det traditionella CAV-systemet. För att undersöka detta sker simuleringar av fiktiva modeller i programmet IDA Indoor Climate &amp; Energy (IDA). IDA är ett simuleringsverktyg som används till att simulera den termiska komforten i byggnader samt byggnadens energianvändning. De olika rumstyperna som simuleras är: klassrummet, kontoret och mötesrummet. De olika fallen är utformade så att de liknar så som de ser ut i verkligheten både till geometri och nyttjandegrad. Om något av fallen visade sig vara en bra kandidat för att förse med VAV fortsätter utredningen med att fastställa hur stort bör flödet vara för att energibesparingen ska bli så stor så att det täcker investeringskostnaden. Den ekonomiska kalkyleringen sker både med en livscykelkostnadsanalys och med en enklare återbetalningstidskalkyl. Resultatet för simuleringarna visade att den enda rumstypen i denna utredning som var lönsam var mötesrummet. Klassrummet och kontoret visade sig båda ge en förlust. Detta var eftersom nyttjandegraden för dessa rum var så pass hög så att ventilationen med VAV var igång nästan lika mycket som för CAV. För mötesrummet var nyttjandegraden betydligt lägre vilket innebar att energibesparingen blev så pass hög att den täckte den höga investeringskostnaden. För mötesrummet gjordes sedan en flödesanalys som visade att rummets luftflöde bör vara dimensionerat för mellan omkring 20 – 30 personer för att vara en lönsam investering.
APA, Harvard, Vancouver, ISO, and other styles
5

Rönnbäck, Niklas. "Behovsstyrd planering av lösa lastbärare och fordonsekipage i ett godstransportsystem." Licentiate thesis, Luleå, 1995. http://urn.kb.se/resolve?urn=urn:nbn:se:ltu:diva-17830.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Pohjanen, Alexander. "Energibalans och inomhusklimat i ett parkeringshus under jord med behovsstyrd ventilation." Thesis, Umeå universitet, Institutionen för tillämpad fysik och elektronik, 2017. http://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-137758.

Full text
Abstract:
Detta examensarbete är gjort hos VVS-konsulterna Skellefteå AB. Det behandlar projektering av ett parkeringshus med hänsyn till värme och ventilation och en jämförelse av ventilationssystem på ett parkeringshus som är planerad att stå klar 2019. Syftet med arbetet är att undersöka hur man projekterar ett parkeringshus ventilation och om det går att spara energi och utgifter genom att använda sig av behovsstyrd ventilation istället för konstant ventilation. Eftersom det är dyrare att investera i behovsstyrd ventilation kommer det också undersöka återbetalningstiden för den investeringen. För att göra undersökningarna har programmet IDA ICE använts för att rita upp en modell av byggnaden och simulera dess energianvändning för att senare jämföra resultaten och se skillnaderna mellan de olika ventilationssystemen. Ett förslag har framtagits på hur ventilationen kan dras och hur fläktluftvärmare ska installeras och hur rören ska dras. Resultatet från simuleringarna gav den totala energiförbrukningen minskade med 705 000 kWh/ med behovsstyrd ventilation jämfört med konstant ventilation. Fläktens energianvändning minskade med 75% och uppvärmningsenergin minskade med 72%. Investeringen för behovsstyrd ventilation jämfört med konstantflödes ventilation är 600 000 kr dyrare och får utifrån beräkningarna i detta arbete en återbetalningstid på 1 år. Livslängden på ventilationssystemet antas vara 25–30 år.<br>This graduate work was conducted in cooperation with the VVS-Consultants Skellefteå AB. It deals with the design of a parking garage regarding heat and ventilation and a comparison of ventilation systems in a parking garage that is scheduled to be ready 2019. The purpose of the work is to investigate how to design a parking garage ventilation and if you can save energy and expenses by using demand-controlled ventilation instead of constant ventilation. As it is more expensive to invest in demand- controlled ventilation, it will also investigate the repayment period for that investment. To do the studies, the IDA ICE program has been used to draw a model of the building and simulate its energy use to compare the results later and see the differences between the different ventilation systems. A proposal has been made on how ventilation can be drawn and how the radiators are to be installed and how the pipes are to be drawn. The result of the simulations resulted in total energy consumption decreased by 705,000 kWh / with demand-controlled ventilation compared to constant ventilation. The fan's energy consumption decreased by 75% and the heating energy decreased by 72%. The investment for controlled ventilation compared to constant flow ventilation is 600,000 kr more and, based on the calculations in this work the repayment period is 1 year. The life expectancy of the ventilation system is assumed to be 25-30 years.
APA, Harvard, Vancouver, ISO, and other styles
7

Johansson, Josefina. "Energieffektivisering av ventilationssystem i en skola : Behovsstyrd ventilation i fastigheten Eken i Karlstad kommun." Thesis, Karlstads universitet, 2018. http://urn.kb.se/resolve?urn=urn:nbn:se:kau:diva-67587.

Full text
Abstract:
I Sverige står bostads-och servicesektorn för nästan 40 % av den totala energianvändningen och därför har många byggnader behov av energieffektivisering. Arbetet utgår från Eken, en del av Karlbergsskolan i centrala Karlstad, som är en kulturmärkt byggnad från 1890-talet. I byggnaden pågår gymnasieutbildning, förskola samt idrottsverksamhet i en gymnastiksal. Byggnaden ventileras i dagsläget med konstant luftflödessystem (CAV). Behovsstyrd ventilation (DCV) innebär att reglera ventilationen efter närvaro och behov, genom att upprätthålla en bra luftkvalité och termisk komfort och samtidigt effektivisera energiförbrukningen. Syftet med detta arbete var att undersöka hur behovsstyrning med IR-sensorer eller CO2-sensorer kan påverka energiförbrukningen och driftkostnader av Ekens ventilationssystem, samt undersöka hur innetemperaturen påverkas vid CO2-reglering jämfört med befintligt driftfall. Målet var att beräkna årliga energibesparingar (MWh/år) och investeringsutrymme (kr) till utgifter som uppkommer vid ombyggnation av dagens CAV-system. Ett ytterligare mål var att beräkna innetemperatur vid olika fall då förutsättningar som rumsplacering, solinstrålning, utetemperatur och intern personbelastning varieras och beroende på CO2-reglerat eller konstant luftflöde. Energibesparingar avseende energi till fläktar och värmebatterier, beräknades i Excel baserat på olika luftflöden beroende på personbelastning. Investeringsutrymmet beräknades utifrån årliga besparingar av driftkostnader. Innetemperaturer beräknades i en dynamisk simuleringsmodell för tre dygn och tre rum med olika förutsättningar. Energibesparingar för IR- och CO2-reglering av ventilationssystemet resulterade i 53 MWh/år (-44 %) respektive 77 MWh/år (-64 %) jämfört med befintligt CAV-system. Efter 15 år bidrog IR- och CO2-reglering till besparingar på ca 520 kkr (IR) respektive 750 kkr (CO2). Skillnaden på innetemperaturen vid behovsstyrt flöde jämfört med konstant luftflöde var lägre än en grad i majoriteten av fallen. Den största skillnaden på 2,7 °C uppstod en solig dag för ett rum med fönster mot sydost. Behovsstyrning är uppenbart fördelaktigt för byggnaden ur energi- och miljöperspektiv. Investeringskostnaden för de två olika metoderna är troligtvis ungefär lika stora och hur ekonomiskt lönsam investeringen är beror på återbetalningstiden. Luftflödesreglering leder inte till några större problem för rumstemperaturen och i annat fall borde temperaturproblem kunna åtgärdas genom solavskärmning eller temporärt ökat ventilationsflöde.<br>In Sweden, the housing and services sector accounts for close to 40 % of the total energy use, hence why many buildings require energy efficiency. This study is based on the Eken building, which is a historical building from the 1890s, a part of Karlbergsskolan in central Karlstad. The building operates with a secondary education, preschool and a gymnasium. It is currently ventilated by a constant air volume-system (CAV). Demand controlled ventilation (DCV) involves controlling the ventilation according to occupancy and requirement, by maintaining acceptable indoor air quality and thermal comfort, while simultaneously decreasing the energy consumption. The purpose of this study was to investigate how demand-controlled ventilation can improve energy efficiency and operating costs of the ventilation system in Eken, using either IR- or CO2-sensors, as well as investigating how indoor temperature is affected by reduced air flow due to CO2-controlled ventilation. The goal was to calculate the annual energy savings (MWh/year) and anticipate the investment range (SEK) for expenses incurred in rebuilding the current CAV-system. An additional goal was to calculate indoor temperature due to CO2-controlled airflow or constant airflow (CAV) under different circumstances. We did this by varying conditions such as location, solar radiation, outdoor temperature and occupancy. Energy savings for fans and heaters were calculated in Excel, based on different airflows depending on occupancy. The investment range was calculated on the basis of annual savings of operating costs. Indoor temperatures were calculated with a dynamic simulation model for three days, in three rooms, with different conditions. Energy savings for an IR- or CO2-controlled ventilation system resulted in 53 MWh/year (- 44 %) and 77 MWh/year (-64 %) respectively compared to consisting CAV-system. After 15 years, IR- and CO2-regulation contributed to savings of about 520 kkr (IR) and 750 kkr (CO2). The difference of indoor temperature during the demand-controlled flow rate in comparison to constant airflow, was less than one degree in the majority of cases. The biggest difference of 2,7 °C occurred on a sunny day in a room with windows facing southeast. Demand-controlled ventilation is clearly beneficial from an energy- and environmental perspective. The investment cost of the two different methods is probably about the same range and the economic profit depends on the payback period. Airflow regulation does not lead to any major temperature problems, however if there are any problems they may be addressed by solar shielding or temporarily increased air flow rate.
APA, Harvard, Vancouver, ISO, and other styles
8

Carlsson, Emil, and Elin Svensson. "Skillnad i energiförbrukning vid byte från CAV-system till VAV-system i en kontorsbyggnad." Thesis, Linnéuniversitetet, Institutionen för byggteknik (BY), 2014. http://urn.kb.se/resolve?urn=urn:nbn:se:lnu:diva-35635.

Full text
Abstract:
Detta arbete är utfört hos Videum AB i Växjö i syfte att visa på skillnader i energiförbrukning mellan deras ventilationssystem samt hur lång tid det skulle ta för en möjlig investering i ett nytt ventilationssystem att återbetala sig. För att uppnå detta utfördes beräkningar på olika faktor som bidrar till den totala energianvändningen hos ventilationssystemet. I denna undersökning behandlas fläktar, golvaggregat och värmeförluster genom ventilation. Den största påverkande faktorn i den totala energiförbrukningen är värmeförluster genom ventilation. Resultatet av vår undersökning visar att det är billigare att använda i VAV-system än ett CAV-system under rådande förhållanden enligt våra beräkningar. En årlig besparing på 29465 kronor per våning vid byte från CAV-system till VAV-system uppnås. Det är värt att byta ventilationssystem även fast att investeringskostnaden inte sparar in sig under dess livstid. Detta på grund av att det blir en mindre årlig kostnad samt att man kommer närmre regeringens krav på minskad energiförbrukning. Avbetalningstiden för VAV-systemet är 33 år per våning.
APA, Harvard, Vancouver, ISO, and other styles
9

Björk, Evelina, and Kim Fast. "Effektivisering av energianvändningen i en förskola." Thesis, Tekniska Högskolan, Högskolan i Jönköping, JTH, Byggnadsteknik, 2011. http://urn.kb.se/resolve?urn=urn:nbn:se:hj:diva-17589.

Full text
Abstract:
This rapport contains an examination of the energy consumption of a kindergarten, which areas that have the largest impact on the energy consumption and what can be done to reduce those areas in ways that are relatively easy and profitable. It is also analyzed if it is possible to reduce the energy consumption from today’s consumption to a consumption that fulfils the demands placed on low energy houses by FEBY. The focus has been on reducing the energy consumption of the areas ventilation, heating system and hot water system, since those seemed to be the easiest ones to affect and since the building is quite recently built. There are different kinds of ventilation systems, at the moment the building have a CAV-system, which means that the ventilation is too high during large parts of the day. There are different ways to manage the ventilation system, for example presence detection, humidity sensors, CO2 sensors, temperature sensors and season adjustment. Many of those are in the end dependent on CO2 sensors to guarantee a good indoor climate, therefore the focus have been placed on this system.   The building is heated through district heating which is relatively easy to connect to a couple of sun panels to contribute to the heating system and hot water system. There are different ways of connecting district heating with solar panels and those are described, as well as the cost and the repayment time. A comparison with a building with an electric heating system has been made as well. It is important to get solutions that are profitable, that the repayment time isn’t too long. Solar cells and wind turbines are examined as well, but the repayment time for solar cells are too long at the moment. The repayment time for solar cells varies between 42 - 75 years, while the expected lifetime is 25 years. Concerning ventilation, a reduced ventilation of 10, 20, 30, 40 and 50 % have been examined. With only reduced ventilation the demands on low energy houses could not be matched, but it was possible in two cases with the use of solar panels. The usage of a wind turbine meant that the ventilation had to be reduced even less to match the demands on low energy houses. The repayment times for the solar panels and the wind turbine are both around 14 years.<br>Rapporten behandlar en undersökning av energiförbrukningen vid en projekterad förskola och vilka poster som har störst inverkan på energiförbrukningen, samt vad som kan göras för att åtgärda dessa på ett sätt som är relativt enkelt och som är lönsamt. Det ses över om det är möjligt att få ner energiförbrukningen från dagens förbrukning som uppfyller BBR:s krav, till att uppfylla de lägre energikraven som gäller för minienergihus enligt FEBY. Med utgångspunkt i energiförbrukningsberäkningen som gjorts och det faktum att förskolan är relativt nybyggd så har fokus lagts på att minska ner posterna ventilation, värmesystemet och varmvattnet då dessa är de poster som är lättast att påverka. När det gäller ventilation finns olika styrsätt, byggnaden har i nuläget ett CAV-system, vilket innebär att ventilation under stora delen av dagen är för hög. Det finns olika saker att styra ventilationen och minska ner den på, däribland närvarogivare, fuktgivare, koldioxidgivare, temperaturgivare samt årstidsanpassning. Många av dessa är dock i slutändan beroende av koldioxidgivare för att garantera inomhusklimatet, så därför har fokus lagts på detta system. Byggnaden värms upp via fjärrvärme och det är relativt enkelt att koppla på solfångare för hjälp av uppvärmning av värmesystemet och varmvattnet. Det finns olika sätt att koppla in solfångare på system med fjärrvärme och de olika sätten beskrivs och undersöks, liksom kostnad och återbetalningstid för en anläggning med solfångare. En jämförelse med en byggnad med eluppvärmning har också gjorts. Det är viktigt att få ekonomisk lönsamhet i det hela och således att återbetalningstiden inte ska vara för lång. Även solceller och vindkraftverk tas upp, dock är återbetalningstiden för solceller i nuläget alltför lång för att vara ekonomiskt försvarbart. Återbetalningstiden för solceller varierar mellan 42 – 75 år, medan den beräknade livslängden ligger på 25 år. När det gäller ventilationen så har minskad ventilation med 10, 20, 30, 40 och 50 % undersökts. Med enbart minskad ventilation kan inte kravet för lågenergihus uppfyllas, men inräknat solfångare så nåddes i två fall lågenergihus. Till sist så innebar medräknandet av ett vindkraftverk att ventilationen inte behövdes minskas lika mycket för att uppfylla kraven för lågenergihus. Återbetalningstiden för solfångarna beräknades till 14 år och återbetalningstiden för vindkraftverket till 14 år.
APA, Harvard, Vancouver, ISO, and other styles
10

Olausson, Jesper. "Energy efficiency in a renovated modern office with activity-based work style." Thesis, Högskolan i Gävle, Energisystem och byggnadsteknik, 2019. http://urn.kb.se/resolve?urn=urn:nbn:se:hig:diva-30113.

Full text
Abstract:
During renovation Ljusåret 2 was converted to a modern office with an activity based work style (ABW) with a Demand Controlled Volume (DCV) ventilation system connected to a closed-loop duct. Cooling is provided through air handling units and active water based beams, the underfloor heating system was kept. Written instruction and specification have been studied for the two different control systems Schneider EcoStructure and Lindinspect. Both control systems have been analyzed according to time schedule, set-point and process value by using different functions in software. To be able to perform a energy audit and look at indoor climate for Ljusåret 2 there have been studies according to underfloor heating, constructions of ventilation system, diversity factor for DCV, closed-loop-ducts, heat losses from ducts, cooling demand and energy certification. According to this audit, energy performance is calculated to 89.1 kWh/m2 according to building energy, activity energy is not audited or calculated. During design phase, an energy calculation was made by an energy consultant with the result of 81.3 kWh/m2. The estimated performance is a 9.6 % increase. This building is designed for Miljöbyggnad certification of level silver and should be ≤ 109 kWh/m2,year. According to audit and calculation for energy performance this level is possible to keep. The estimated energy performance have been calculated with only 4 month of statistics from January until April 2019 because Ljusåret 2 have just been renovated. District heating has been estimated through the energy signature by data from energy meter. Electrical components for the building have been measured and energy usage calculated. Energy produced by compression chiller have been estimated with calculated performance from design phase and adding heat transfer between rooms and supply ducts. Energy between rooms and supply ducts were not included in energy calculation during the design phase. According to the control system for the DCV system there have been some issues with high temperature in supply ducts even when they are supplied with 15 ºC from air- handling unit. There have been measurement to the ventilation system 5701-5704 that is connected to a close-loop duct with a result of temperatures between 15.2 ºC up to 21.4 ºC and the velocity has varied between 0.05-2.1 m/s in different measurement spots. This is an increase of 6.4 ºC. A heat transfer calculation have been made in Paroc Calculus to estimate heat transfer between room and supply ducts. The results of this calculation indicates the same level of temperature increases as when the system was measured. With no thermal insulation cooling capacity is lost to half after less than 5 m with a velocity of 0.2 m/s, after 15 m with a velocity of 1 m/s and 30 m with a velocity of 2 m/s . This should be compared with supply duct with 20 mm of thermal insulation that has lost its cooling capacity after less than 13 m with a velocity of 0.2 m/s, after 63 m with a velocity of 1 m/s and is increase with 4 ºC after 100 m with a velocity of 2 m/s. Using closed-loop ducts with velocity below 2.0 m/s and without thermal insulation combined with under tempered supply air is not a good combination. Even short length with low velocity and lack of thermal insulation is devastating because of heat transfer according to logarithmical temperature difference between room and supply ducts. A closed-loop duct is often designed as a pressure chamber and recommended when using DCV and/or VAV ventilation to avoid problems with noise and to be able to reduce the need of dampers. Problems with temperature increasing according to velocity in ducts must be taken in consideration. For Ljusåret 2 this will affect district heating usage where ducts are placed because underfloor heating must compensate heat transfer. Chilled water must be provided an extra time for rooms with both DCV and chilled beams and rooms with only DCV is less comfortable which they could been with a correct installation.
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!

To the bibliography