Academic literature on the topic 'Biocapteurs'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Biocapteurs.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "Biocapteurs"

1

Osbild, D., M. Babut, and P. Vasseur. "Les biocapteurs appliqués au contrôle des eaux: Revue - État de l'art." Revue des sciences de l'eau 8, no. 4 (2005): 505–38. http://dx.doi.org/10.7202/705236ar.

Full text
Abstract:
Cet article présente l'ensemble des biocapteurs en cours d'étude et proposés pour le contrôle en continu, automatisé et in situ de la qualité des eaux. Le principe des systèmes, étudiés jusqu'ici majoritairement en laboratoire et sur pilote, sera donné avec leurs performances au plan sensibilité et spécificité de détection des polluants hydriques. Ces performances conditionnent leur domaine d'application : les systèmes très sensibles étant affectés au contrôle des eaux d'alimentation et des eaux souterraines, les moins sensibles au contrôle des effluents très contaminés. Les biocapteurs peuvent se caractériser par deux de leurs composantes principales : - le réactif biologique ou biocatalyseur, sensible au(x) polluant(s); - le détecteur appelé transducteur, qui traduit la réponse biologique du biocatalyseur en un signal électrique. Le transducteur peut être de type optique, électrochimique, ampérométrique principalement, ou piézoélectrique. Trois grands types de biocapteurs peuvent être distingués selon la nature du biocatalyseur : - les bioréacteurs, basés sur l'étude des réponses comportementales des vertébrés (poissons) et d'autres organismes aquatiques (microcrustacés, bivalves): - les biosondes cellulaires reposant sur l'étude des fonctions métaboliques telles que la respiration, la bioluminescence, la photosynthèse de microorganismes immobilisés (bactéries, microalgues, levures) ou libres (boues activées) dans le milieu analysé: - les biocapteurs "d'affinité" basés sur l'utilisation d'enzymes ou d'anticorps, chargés de détecter respectivement les substrats et inhibiteurs enzymatiques spécifiques, ou les substances antigéniques vis à vis desquelles les anticorps ont été développés. Ces systèmes sont, par principe, les plus spécifiques mais aussi les plus sensibles. Ils ne couvrent, cependant, qu'une gamme encore très limitée de micropolluants hydriques. Le degré d'autonomie d'un biocapteur, sa facilité d'utilisation et de maintenance et sa fiabilité, sont des éléments qui rentrent en ligne de compte dans les performances. Ces qualités devront être évaluées lors de la phase de validation in situ, essentielle et déterminante pour juger de l'intérêt du système en conditions de fonctionnement réel.
APA, Harvard, Vancouver, ISO, and other styles
2

-COMTAT, M. "Les biocapteurs." Revue de l'Electricité et de l'Electronique -, no. 06 (2000): 77. http://dx.doi.org/10.3845/ree.2000.060.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Coisne, Stéphane. "Biocapteurs et applications." Bio tribune magazine 3, no. 1 (2002): 51–52. http://dx.doi.org/10.1007/bf03023033.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Comtat, Maurice, and Alain Bergel. "Biocapteurs: rêve ou réalité industrielle ?" Biofutur 1997, no. 171 (1997): 33–36. http://dx.doi.org/10.1016/s0294-3506(97)88042-8.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Monnier, Anne-Laure. "Les biocapteurs à petits pas." Biofutur 1999, no. 194 (1999): 94–95. http://dx.doi.org/10.1016/s0294-3506(99)90132-1.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

-BLUM, Loïc. "Les biocapteurs enzymatiques à fibres optiques." Revue de l'Electricité et de l'Electronique -, no. 06 (2000): 83. http://dx.doi.org/10.3845/ree.2000.062.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Gorgy, K. "Nanotechnologies : les biocapteurs au service de l’allergie." Revue Française d'Allergologie 55, no. 3 (2015): 181–82. http://dx.doi.org/10.1016/j.reval.2015.01.029.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Pandard, P., and P. Vasseur. "Biocapteurs pour le contrôle de la toxicité des eaux : application des bioélectrodes algales." Revue des sciences de l'eau 5, no. 3 (2005): 445–61. http://dx.doi.org/10.7202/705141ar.

Full text
Abstract:
L'amélioration de la qualité de l'environnement passe par la réalisation de contrôles de toxicité in situ et en continu des sources de pollution ou des milieux contaminés, à l'aide de systèmes automatisés à réponse rapide. Les systèmes donnant une réponse en temps réel permettent d'intervenir immédiatement à la source, d'interrompre le rejet d'un flux toxique et de prévenir ainsi les accidents de pollution. Ce type de stratégie ne peut être développé qu'au moyen de biocapteurs : les méthodes d'essais conventionnelles n'autorisent que des contrôles de toxicité épisodiques, en laboratoire, effectués dans des conditions statiques quelque peu éloignées des conditions dynamiques. Nous nous sommes intéressés à la mesure de l'activité photosynthétique d'algues unicellulaires immobilisées. La photosynthèse induite par des stimuli lumineux est en effet un processus dont la réponse est immédiate et aisément mesurable à l'aide de transducteurs électrochimiques. Il apparaît donc intéressant d'utiliser ces réactions photosynthétiques pour la détection des polluants. Deux dispositifs mesurant l'activité photosynthétique d'algues unicellulaires ont été testés. Le premier dispositif mesure le transfert d'électrons le long de la chaîne photosynthétique lors d'une illumination des micro-organismes. Le second système permet de quantifier la production d'oxygène résultant de cette excitation lumineuse. La mesure du transfert d'électrons photosynthétiques nécessite l'addition d'une substance oxydo-réductible (médiateur) dans le milieu pour capter ces électrons. De la série de médiateurs testés, seuls les dérivés à caractère lipophile (2,6-diméthylbenzoquinone et p-benzoquinone) ont permis de mesurer un transfert d'électrons. Toutefois la durée de vie de ce biocapteur s'est révélée limitée à moins de 24 heures, ce qui exclut toute utilisation en continu. Le second dispositif développé présente en revanche une longévité d'une semaine, ce qui le rend intéressant en vue d'une utilisation in situ. Les performances de ce capteur à oxygène ont été testées sur des produits de type herbicides, cyanures, métaux et comparées aux valeurs obtenues à l'aide de tests algues classiques ou de méthodes de détection rapide de la toxicité.
APA, Harvard, Vancouver, ISO, and other styles
9

Boujday, Souhir, and Michèle Salmain. "Nanoparticules d’or pour les biocapteurs : lecture optique de la reconnaissance moléculaire." Photoniques, no. 106 (January 2021): 39–43. http://dx.doi.org/10.1051/photon/202110639.

Full text
Abstract:
Les propriétés extraordinaires des nanoparticules d’or et/ou d’argent en ont fait des objets courtisés par les scientifiques toutes disciplines confondues. L’intensité de leur couleur ainsi que leur grande sensibilité optique au milieu environnant en font de puissants transducteurs pour les biocapteurs ; que ce soit grâce à des spectrophotomètres ou simplement par observation à l’oeil nu. Elles assurent la lecture de la reconnaissance moléculaire via des scénarios variés alliant simplicité et faible coût.
APA, Harvard, Vancouver, ISO, and other styles
10

CAGNARD, O., E. ALOCHE, F. NAKACHE-DANGLOT, et al. "Tests de capteurs biologiques pour l’évaluation de l’écotoxicité d’eaux usées traitées." Techniques Sciences Méthodes 6, no. 6 (2021): 87–102. http://dx.doi.org/10.36904/tsm/202106087.

Full text
Abstract:
Comment peut-on mettre en lumière et discriminer les pollutions dues aux micropolluants en sortie de stations d’épuration ? Les mesures physico-chimiques en continu sur le terrain ainsi que les mesures chimiques en laboratoire ne rendent pas compte de la réalité de la pollution dite diffuse due aux micropolluants. Trois types de bioessais ou biocapteurs ont été testés, de juillet 2019 à mars 2020, sur la station d’épuration de Saint-Fons (Rhône, France) afin de déterminer ce qu’ils peuvent apporter à la surveillance de la qualité des eaux usées traitées : les bancs d’expérimentation ex situ travaillant à l’aide de populations de gammares et deux capteurs en continu innovants, un capteur microbien mettant en oeuvre une communauté bactérienne endogène et une station de biosurveillance dont le principe repose sur une base multiespèce (crustacés, gastéropodes et sangsues). Ce type de mesures offre clairement une complémentarité aux analyses chimiques. Ils permettent de rendre visibles des stress biologiques sur des périodes prolongées ou bien en temps réel. Les capteurs physico-chimiques offrent des réponses globales, mais n’ont pas une sensibilité suffisante pour détecter une pollution diffuse. Les analyses chimiques sur les prélèvements moyens 24 heures ne donnent pas de réponse pertinente. Sans biocapteur, la surveillance analytique et instrumentale actuelle des stations d’épuration ne permet pas d’évaluer les impacts biologiques dus aux micropolluants, sur la vie aquatique. Ces tests montrent les aspects bénéfiques d’un traitement tertiaire dédié à la lutte contre les micropolluants, et la pertinence d’une biosurveillance des eaux rejetées dans les milieux naturels. Les prochaines recherches visant à accélérer le déploiement de ce type d’outil devront être axées sur la discrimination du type de pollution détectée.
APA, Harvard, Vancouver, ISO, and other styles
More sources

Dissertations / Theses on the topic "Biocapteurs"

1

Bacha, Saliha. "Modélisation de biocapteurs électroenzymatiques." Toulouse 3, 1993. http://www.theses.fr/1993TOU30218.

Full text
Abstract:
Les biocapteurs enzymatiques a detection amperometrique sont de plus en plus utilises pour le dosage de composes interessant la medecine, l'environnement ou l'agro-alimentaire. Ils sont constitues d'une electrode associee a un systeme de reconnaissance biologique constitue d'une ou plusieurs enzymes. La modelisation de tels systemes consiste a resoudre les equations aux derivees partielles de bilan matiere en regime transitoire pour les differentes especes en solution. La resolution est effectuee par la methode numerique des volumes finis qui offre l'avantage de la souplesse dans le choix du maillage de l'espace, particulierement importante dans le cas des capteurs a enzymes immobilisees. Apres avoir optimise les parametres numeriques, le modele est valide sur les resultats experimentaux obtenus avec des capteurs monoenzymatiques. L'etude de l'influence des parametres biochimiques, hydrodynamiques ou de position de l'enzyme, sur l'amplitude du signal et le temps de reponse permet de choisir le capteur le plus performant et les meilleures conditions experimentales. Le modele est ensuite applique a l'etude des electrodes composites a pate de carbone. La complexite des phenomenes mis en uvre dans de telles structures a necessite une approche experimentale afin de cerner avec precision les cas pour lesquels le modele est directement applicable. Le modele est enfin etendu aux systemes bienzymatiques. Une attention particuliere est portee aux phenomenes d'inhibition de la catalyse enzymatique et une classification des capteurs est proposee en fonction des solutions qu'ils apportent pour s'affranchir des inhibiteurs, pour amplifier le signal ou ameliorer la selectivite
APA, Harvard, Vancouver, ISO, and other styles
2

Perrissol, Philippe. "Conception d'antennes pour biocapteurs implantables." Thesis, Nice, 2015. http://www.theses.fr/2015NICE4118.

Full text
Abstract:
De tous temps, l'amélioration des moyens de guérison et de prévention des maladies a constitué un enjeu majeur de nos sociétés. Les possibilités offertes désormais par les technologies modernes ont permis de multiplier le nombre d'applications médicales mais toutes ces pratiques nouvelles ont un impact dans le domaine de l'expérimentation animale et impliquent aussi un suivi sanitaire à grande échelle. Le travail présenté dans cette thèse a pour but de moderniser la surveillance de l'état de santé des souris de laboratoire, et s'inscrit dans un projet collaboratif entre le LEAT et TIRO-MATOs. L’objectif est la conception d’un système capable de faciliter ce suivi au quotidien. Pour cela, la conception d'une antenne à 433MHz, connectée à un capteur de température, implantable dans une souris et intégrant notamment l'impact de l'environnement biologique a tout d’abord été étudiée. Après caractérisation des éléments obtenus, la faisabilité d’un système de géolocalisation est présentée. Afin de disposer également de la capacité d’identification des sujets, cette étude s’est poursuivie à 868 MHz (standard RFID). Dans cette partie, l’antenne interrogatrice placée sous la cage, a été plus particulièrement étudiée. Afin de comparer les différentes antennes obtenues, des mesures de puissance récupérées par le lecteur (RSSI) sont réalisées, utilisant pour cela des phantoms de souris spécialement mis au point pour cette étude. Les conclusions tirées par comparaison notamment avec les résultats de phantoms numériques ont permis de concevoir un dispositif de diversité à 4 antennes et de le tester en présence de un à quatre phantoms dans quatre différentes zone de la cage<br>The improvement of the methods of cure and prevention of diseases has always constituted a major objective in our societies. The possibilities offered by modern technologies allow the multiplication of the number of medical applications but all these new practices have an impact on pre-clinical animal studies which require a large-scale health status follow-up. This work, which aims at modernizing the supervision of laboratory mice in an animal facility, is a collaborative project between the LEAT and TIRO-MATOs labs. The objective is the design of a system allowing to facilitate this follow-up for the researchers while leading to new research areas. Thus, we first studied the conception of an antenna working at 433MHz, connected to a mouse implanted temperature sensor, taking also into account the biological environment impact. After having characterized the obtained elements, the feasibility of a localization system has been studied. In order to identify several mice within a cage, the study has focused on using an UHF RFID (Radio Identification Frequency) standard (868 MHz). In this part, a reader antenna placed under the cage has been investigated. Different solutions have been proposed and compared thanks to the received power (RSSI level) recorded by the reader. For that purpose, mice “phantoms” have been specifically developed. The comparison of the different results obtained particularly with numerical mice “phantoms”, led to the conception of a reading diversity system composed of 4 antennas. This last system allows to detect the presence of up to four phantoms within a cage divided into four zones
APA, Harvard, Vancouver, ISO, and other styles
3

Meini, Nadir. "Conception et réalisation de biocapteurs impédimétriques." Thesis, Lyon 1, 2014. http://www.theses.fr/2014LYO10074/document.

Full text
Abstract:
L'objectif du travail de recherche concerne la conception et la réalisation de biocapteurs à base de mesures impédimétriques, pour lesquels la demande est forte dans différents domaines d'intérêt sociétal, en particulier l'environnement, la sécurité alimentaire et le biomédical. Les biocapteurs sont des moyens d'analyse en plein essor à la fois rapides, sélectifs et peu coûteux applicables à des domaines extrêmement variés (environnement, santé, agroalimentaire,…). Dans ce type d'outil, un élément sensible de nature biologique (anticorps, enzyme, microorganisme, ADN…) doté d'un pouvoir de reconnaissance pour un analyte ou un groupe d'analytes est associé à un transducteur pouvant être de type électrochimique, optique ou thermique. Dans la première partie de ce travail, un aptasensor a été développé pour la détection de la thrombine. Deux aptamères different ciblant la thrombine étaient directement immobilisés sur l'électrode en or. L'aptasensor élaboré présente une grande sensibilité, spécificité et stabilité pour la thrombine. Dans la seconde partie, en utilisant la spectroscopie d'impédance électrochimique (EIS), nous avons surveillé l'immobilisation de protéines et sans marquage sur une surface d'or, au moyen d'une stratégie d'électro-adressage, compatible avec la production de biopuces pour multi-détection.Cette fonctionnalisation est réalisée par la cycloaddition alcyne / azoture, mieux connu comme la réaction «clic». Enfin, un biocapteur utilisant des protéines de phage à été développé pour la détection de E.coli<br>The objective of the research concerns the design and realization of biosensors based impedimetric measures, for which there is strong demand in various societal benefit areas, particularly the environment, food security and biomedical.Biosensors are rapid, selective and inexpensive devices that combine a biological recognition element, the so-called bioreceptor (e.g. enzymes, antibodies, DNA or microorganisms) to a physical transducer (e.g. electrochemical, optical, thermal or piezoelectrical). They can be used to detect one specific analyte or one family of analytes for a wide range of applications (e.g. environment, food, health). In the first part of this work, an aptasensor was developed for thrombin detection. Two different aptamers targeting thrombin were directly immobilized on the gold electrode. The aptasensor exhibits high sensitivity, specificity and stability in the detection of thrombin. In the second part, using electrochemical impedance spectroscopy (EIS), we have, monitored label-free protein immobilization on a gold surface, through a strategy of electroaddressing, compatible with the production of microarrays for multi-detection. This functionalization is achieved via the alkyne/azide cycloaddition, better known as the "click" reaction.Finally, a biosensor using phage proteins was developed for detecting E. coli
APA, Harvard, Vancouver, ISO, and other styles
4

Azuelos, Paul. "Développement de biocapteurs en optique intégrée." Thesis, Rennes 1, 2018. http://www.theses.fr/2018REN1S069/document.

Full text
Abstract:
Le développement de capteurs pour la détection de molécules présentes en très faible concentration est un enjeu sociétal et économique. Il permet de répondre à des besoins de mesure d’analytes dans les secteurs de la santé, de la défense ou encore de l’environnement. Les capteurs optiques intégrés possèdent plusieurs avantages permettant de répondre à ces problématiques. Dans cette thèse, des capteurs optiques intégrés à base de deux micro-résonateurs sont développés. Ils fonctionnent dans le domaine du proche infrarouge et permettent de détecter des molécules d’intérêt présentes en très faible quantité dans un échantillon biologique. Dans un premier temps, les critères de performances comme la sensibilité ou la limite de détection de micro-résonateurs seuls sont définis et optimisés. Puis, l’intérêt de transducteurs à base de deux micro-résonateurs cascadés ou insérés dans une structure interférométrique de type Mach-Zehnder permettant d’utiliser l’effet Vernier est mis en avant. Un algorigramme permettant d’optimiser la conception des transducteurs à effet Vernier est mis en place. Son efficacité est démontrée par la fabrication d’un transducteur à effet Vernier en matériaux polymères qui possède des performances dans l’état de l’art. Ensuite, des transducteurs en matériau silicium poreux sont étudiés. Ce matériau poreux permet d’augmenter la sensibilité du capteur en facilitant le greffage des analytes dans la structure. Les guides en silicium poreux pour la réalisation de micro-résonateurs simples sont optimisés théoriquement. L’avantage de l’utilisation conjointe de guides en polymères et en silicium poreux couplés sur la même puce intégrée, qui permet à la fois de réduire les pertes de propagation optique et d’augmenter la sensibilité du transducteur, ainsi qualifié d’hybride, est détaillé dans ce manuscrit. Les performances en sensibilité et limite de détection de transducteurs à effet Vernier hybride fabriqués à l’aide de guides en silicium poreux et en polymères sont étudiées théoriquement afin de prédire les performances de ces dispositifs. Enfin la mise en œuvre et les premiers essais de fabrication de transducteurs hybrides avec des guides en polymères et en silicium poreux sont détaillés<br>The development of biosensors for the detection of extremely low concentration analytes is an economic and societal challenge. It ensures the needs to detect analytes in the economic fields of healthcare, defense and environment. Integrated optical sensors have several advantages to address these challenges. In this thesis, near infrared integrated biosensors for detection of low concentration molecules in biological samples are developed. They are based on two integrated micro-resonators transducers. Firstly, performances criterions such as sensitivity and limit of detection are defined and optimized for single micro-resonator biosensors. The advantage of micro-resonator transducers based on the Vernier effect are presented. To do so, a flowchart is developed in order to optimize the design of Vernier effect integrated transducers based on cascaded micro-resonators or micro-resonators positioned in a Mach-Zehnder interferometric structure. The efficiency of the design procedure is tested by the fabrication of a polymer transducer based on the Vernier effect with state of the art performances. Then, transducers based on porous silicon material are studied. This porous material eases the penetration and the grafting of the analytes in the sensor. Porous silicon waveguides are theoretically optimized for the fabrication of single micro-resonators. The interest of the implementation of polymer and porous silicon waveguides coupled on the same integrated chip, in order to reduce optical propagation losses and to increase sensor sensitivity, is demonstrated. The performances in sensitivity and limit of detection of hybrid porous silicon and polymer waveguides Vernier effect transducers are theoretically studied in order to estimate the performances of these integrated biosensors. Eventually, the design and the first fabrication trials of hybrid porous silicon and polymer waveguides transducers are presented
APA, Harvard, Vancouver, ISO, and other styles
5

Romette, Jean-Louis. "Biocapteurs à oxydases : études et applications." Compiègne, 1986. http://www.theses.fr/1986COMPE058.

Full text
Abstract:
Après une introduction montrant l’implication de l’analyse enzymatique dans le domaine plus large de la biochimie, une étude de marché est réalisée au niveau mondial, européen et français. Cette étude fait apparaître les tendances très nettes du développement en matière d’appareil d’analyse biochimique vers l’utilisation des enzymes immobilisées dans de petits appareils monoparamètriques automatiques. Les biocapteurs représentent les futurs outils de l’analyste industriel ou clinicien. Une méthode est décrite pour immobiliser et utiliser des oxydases comme élément actif de biocapteur. L’application de ce système est développée à travers un équipement. Une dizaine de paramètres peuvent être déterminés par ce dispositif. La méthode est testée dans différents secteurs de l’industrie pour montrer sa crédibilité.
APA, Harvard, Vancouver, ISO, and other styles
6

Mano, Nicolas. "Electrodes modifiées pour l'élaboration de nouveaux biocapteurs." Bordeaux 1, 2001. http://www.theses.fr/2001BOR12396.

Full text
Abstract:
De nos jours, le développement de biocapteurs enzymatiques basés sur le système (NAD+/NADH) est d'un grand intérêt pour l'analyse de substrats biologiques. Une difficulté lors de la construction d'un tel biocapteur réside dans l'immobilisation des diverses composantes biologiques à la surface de l'électrode. L'immobilisation du matériel biologique doit permettre de conserver l'activité de l'enzyme mais aussi d'assurer une connexion électrique optimale entre le site rédox de l'enzyme et l'électrode. Nous proposons ici une méthode d'immobilisation innovante qui nous permet de contrôler, au niveau moléculaire, la fixation des différentes composantes à la surface de l'électrode. Cette méthode de modification par voie électrostatique permet en outre de conserver l'intégrité de l'enzyme. La première étape consiste à adsorber à la surface de l'électrode une monocouche de nitrofluorénones qui joue le role de médiateur rédox. L'étape suivante met en jeu une monocouche de calcium servant de lien entre le médiateur rédox et une monocouche de coenzyme. L'interaction entre ces trois composés, que nous avons pu montrer par EQCM et RMN 31p, conduit à un complexe formé entre les groupements phosphates du coenzyme, le calcium et un groupe carboxyl du médiateur. La monocouche de coenzyme ainsi obtenue sert alors d'ancrage naturel pour une monocouche de l'enzyme étudiée. Appliquée à la glucose déshydrogénase, cette simple procédure de modification nous a permis d'obtenir des sensibilités de l'ordre de 0. 2 uA CM -2 mM-1 lors de la détection de glucose. Nous avons aussi étendu cette procédure de modification avec succès à d'autres systèmes enzymatiques tels que la glutamate déshydrogénase et l'alcool déshydrogénase, montrant ainsi qu'elle peut être généralisée avec facilité et à faible coût à de nombreux systèmes enzymatiques.
APA, Harvard, Vancouver, ISO, and other styles
7

Deiss, Frédérique. "Développement de réseaux multiplexés de biocapteurs électrochimiques." Thesis, Bordeaux 1, 2009. http://www.theses.fr/2009BOR13883/document.

Full text
Abstract:
Ce travail de thèse a porté sur le développement de réseaux de micro- et nanocapteurs opto-électrochimiques pour la bioanalyse. Ils répondent à la demande grandissante dans le domaine de la recherche et du diagnostic pour des outils permettant de réaliser de multiples analyses simultanément avec des échantillons de faibles volumes. Ces nouvelles biopuces de haute densité sont fabriquées à partir de faisceaux cohérents de fibres optiques. Une des deux faces est micro- ou nanostructurée par une attaque chimique, puis fonctionnalisée avec une sonde biologique. La première biopuce est un réseau de nanocapteurs fluorescents à ADN où les sondes ont été immobilisées grâce aux propriétés d’électropolymérisation du pyrrole. La lecture est réalisée à distance au travers du faisceau d’imagerie. En combinant la technique d’immobilisation avec des microleviers électrochimiques, plusieurs sondes différentes ont pu être adressées sur le même réseau nanostructuré. La seconde biopuce permet d’effectuer des immunodosages multiplexés en utilisant l’imagerie électrochimiluminescente résolue à l’échelle d’une microsphère. Le développement de cette technique permet de combiner les avantages de l’électrochimiluminescence avec des immunodosages multiplexés. L’élaboration de ces réseaux allie différentes techniques physico-chimiques, notamment électrochimiques, pour obtenir des biopuces avec un fort potentiel, grâce à une densité et un degré de multiplexage importants<br>This work presents the development of optoelectrochemical micro- and nanosensor arrays for bioanalytical applications. These platforms respond to the growing need in research and diagnostic for tools allowing multiple and simultaneous analysis in small-volume samples. These new high density biochips are made from coherent optical fiber bundles: one face is micro- or nanostructured by chemical etching and then functionnalized with biological probes. The first biochip is a fluorescent DNA nanosensor array where probes have been immobilized by electrodeposition of a polypyrrole thin film. The detection of the hybridization is remotely performed through the imaging fiber. Different probes were succesfully addressed onto the same nanostructured array thanks to electrochemical cantilevers. The second biochip allows multiplexed sandwich immunoassays using electrochimiluminescent imaging resolved at the single bead level. In particular, the development of this new readout mechanism allows extending electrochemiluminescent detection for multiplexed immunoassays. Design and implementations of both platforms take advantages of different physical and chemical techniques, especially electrochemical, to obtain biochips with a great potential through high density and high multiplexing level
APA, Harvard, Vancouver, ISO, and other styles
8

Romette, Jean-Louis. "Les Biocapteurs à oxydases études et applications /." Grenoble 2 : ANRT, 1986. http://catalogue.bnf.fr/ark:/12148/cb37600758m.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Renard, Martial. "Construction de biocapteurs à partir de fragments d'anticorps." Paris 6, 2003. http://www.theses.fr/2003PA066282.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Haddour, Naoufel. "Réalisation d'assemblages biologiques électroactifs : application aux biocapteurs d'affinité." Université Joseph Fourier (Grenoble), 2005. http://www.theses.fr/2005GRE10120.

Full text
Abstract:
Ce mémoire est consacré à l'élaboration d'assemblages surfaciques originaux à base de polymères conducteurs dans le but d'améliorer les performances analytiques des biocapteurs d'affinité. Tout d'abord, une nouvelle stratégie de transduction photoélectrochimique directe d'immunoréactions a été élaborée au moyen d'électrodes modifiées par un polymère photosensible biotinylé. Ce dernier est électrogénéré à partir d'un complexe tris(bipyridine) de ruthénium(II) substitué de groupements pyrrole et d'entités biotine. Le film polymère est utilisé à la fois pour l'immobilisation de la toxine du choléra biotinylée à travers l'interaction affine biotine/avidine et la détection directe de l'anticorps correspondant via l'altération des propriétés électrochimiques et photo physique du polymère. Une méthode originale d'immobilisation affine de protéines sur des films polymères électrogénérés a été également étudiée. La synthèse et l'électropolymérisation d'un monomère pyrrole-nitrilotriacétate a permis l'élaboration d'un film polymère capable de complexer des ions cuivre et d'immobiliser de manière réversible une protéine histidinylée. Enfin, l'utilisation d'un complexe tris(bipyridine) de fer(II) substitué par des groupements biotine comme espaceur biotinylé a permis la réalisation d'une architecture supramoléculaire comportant plusieurs couches d'avidine autorisant l'immobilisation d'une forte teneur en sondes oligonucléotides. Cette immobilisation en volume des sondes oligonucléotides a conduit à une augmentation notable de la sensibilité de la détection gravimétrique de la cible complémentaire par rapport à une immobilisation en monocouche<br>This work is dedicated to the realization of original surface assemblies based on conducting polymers with the aim to improve analytical performances of Affinity biosensors. Firts, a new photoelectrochemicallabel-free transduction approach, was developed using electrodes modified by biotinylated photosensitive polymer. The latter was electrogenerated from on a tris(bipyridinyl) ruthenium(II) complexe bearing biotin and pyrrole groups. The resulting polypyrrolic film was used for the immobilization of biotinylated cholera toxin through avidin-biotin interaction and the label-free detection of the corresponding antibody via the change of electrochemical an photophysical properties of the polymer. Ln parallel, an original method of protein immobilization onto electropolymerized film based on affinity interactions was studied. The synthesis and electropolymerisation of a pyrrole-nitriloacetate mono mer allowed the elaboration of a polymer film for the coordination of copper ions and reversible immobilization of histidine-tagged protein
APA, Harvard, Vancouver, ISO, and other styles
More sources

Books on the topic "Biocapteurs"

1

P, Buck Richard, and International Symposium on Biosensors: Fundamentals and Applications (1989 : University of North Carolina at Chapel Hill), eds. Biosensor technology: Fundamentals and applications. M. Dekker, 1990.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
2

1937-, Wise Donald L., ed. Applied biosensors. Butterworths, 1989.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
3

1955-, Blum Loïc J., and Coulet Pierre R. 1941-, eds. Biosensor principles and applications. M. Dekker, 1991.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
4

Joseph, Ayers, Davis Joel L. 1942-, and Rudolph Alan, eds. Neurotechnology for biomimetic robots. MIT Press, 2002.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
5

Neeti, Sadana, and ScienceDirect (Online service), eds. Handbook of biosensors and biosensor kinetics. Elsevier Science, 2010.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
6

1946-, Taylor Richard F., and Schultz J. S. 1933-, eds. Handbook of chemical and biological sensors. Institute of Physics Pub., 1996.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
7

Royal Society of Chemistry (Great Britain), ed. Engineering the bioelectronic interface: Applications to analyte biosensing and protein detection. RSC Pub., 2009.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
8

Meeting, American Chemical Society. Diagnostic biosensor polymers: Developed from a symposium sponsored by the Division of Industrial and Engineering Chemistry, Inc., at the 205th National Meeting of the American Chemical Society, Denver, Colorado, March 28-April 2, 1993. American Chemical Society, 1994.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
9

L, Gorton, ed. Biosensors and modern biospecific analytical techniques. Elsevier, 2005.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
10

1961-, Cooper Jon, and Cass A. E. G, eds. Biosensors: A practical approach. 2nd ed. Oxford University Press, 2004.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
More sources

Book chapters on the topic "Biocapteurs"

1

Marty, Jean-Louis. "20 • Biocapteurs." In Les capteurs en instrumentation industrielle. Dunod, 2017. http://dx.doi.org/10.3917/dunod.asch.2017.01.0901.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Baraket, Abdoullatif, Michael Lee, Nadia Zine, et al. "Fabrication d’un biocapteur pour la détection de la cytokine TNF-α : Etude de l’inflammation après l’implantation des LVADs." In Instrumentation et Interdisciplinarité. EDP Sciences, 2020. http://dx.doi.org/10.1051/978-2-7598-1206-6-022.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Baraket, Abdoullatif, Michael Lee, Nadia Zine, et al. "Fabrication d’un biocapteur pour la détection de la cytokine TNF-α : Etude de l’inflammation après l’implantation des LVADs." In Instrumentation et Interdisciplinarité. EDP Sciences, 2020. http://dx.doi.org/10.1051/978-2-7598-1206-6.c022.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Baraket, Abdoullatif, Michael Lee, Nadia Zine, et al. "Fabrication d’un biocapteur pour la détection de la cytokine TNF-α : Etude de l’inflammation après l’implantation des LVADs." In Instrumentation et Interdisciplinarité. EDP Sciences, 2020. https://doi.org/10.1051/978-2-7598-1116-8.c022.

Full text
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!

To the bibliography