Academic literature on the topic 'Bourdon Tube Pressure Gauge'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Bourdon Tube Pressure Gauge.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "Bourdon Tube Pressure Gauge"

1

Amritanandamayi Devi, Mata, Ganesha Udupa, and Pramod Sreedharan. "Anti-Bourdon tube pressure gauge." Measurement 101 (April 2017): 190–99. http://dx.doi.org/10.1016/j.measurement.2017.01.026.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Fan, Xue Qun, Li Xiang Zhang, Feng Xu, Yu Ming Gu, Jian Zhang, and Jia Wu Li. "The Structural Design Research of Bourdon Tube." Applied Mechanics and Materials 201-202 (October 2012): 279–82. http://dx.doi.org/10.4028/www.scientific.net/amm.201-202.279.

Full text
Abstract:
Bourdon tube has been widely used in the fluid testing so far, and this paper introduces the chemical and physical behaviors of beryllium bronze QBe2.0 detailedly which mainly makes up bourdon tube; It analyzes the influences of elastic limit in bending on bourdon tube the chemical elements and coating technology bring; Simultaneously, it focuses on the design of the base of tube and the assembly body, points out the location of bourdon tube in bourdon tube pressure gauge; and the design of this paper can guarantee the normal work of bourdon tube in the sealed environment through the theory an
APA, Harvard, Vancouver, ISO, and other styles
3

Ghodsi, Mohammad Reza. "Using Instrumentation Magnetic Level Gauge to Measure the Local Level of Industrial Tanks (Case Study of Ramin Power Plant)." Journal of New Achievements in Electrical, Computer and Technology 2, no. 4 (2022): 17–38. https://doi.org/10.5281/zenodo.7046766.

Full text
Abstract:
Measuring and observing the local level of industrial reservoirs is always considered one of the most important issues in all industries, to the extent that different methods are used in the field of precision instruments. On the other hand, with the passage of time, due to the wear and tear of old local level gauges and the lifespan of their parts, these devices are always faced with a decrease in measurement accuracy as well as an increase in equipment failure and inefficiency. The focus of this article is on the local measurement of the level, compared to the centralized measurement located
APA, Harvard, Vancouver, ISO, and other styles
4

Wu, Ze Qiu. "An Explore about Low-Price Pressure Sensor." Applied Mechanics and Materials 121-126 (October 2011): 1200–1203. http://dx.doi.org/10.4028/www.scientific.net/amm.121-126.1200.

Full text
Abstract:
In low-end equipment developing it is often have the requirement of use low-cost pressure sensors, but the maketing pressure sensors’s price is very higher than the SCM. For decrease the price of the equipment to suit the market we explored a low-cost pressure sensor disgn. It is based on the bourden tube pressure gauge, SCM control system, Gray code disc and photoelectronic reading technology. The design can suit the certain low-cost equipment.
APA, Harvard, Vancouver, ISO, and other styles
5

Wongthep, Padipat, Hiroaki Kajikawa, Tawat Changpan, et al. "Final report on key comparison APMP.M.P-K7.3 in hydraulic gauge pressure from 10 MPa to 100 MPa." Metrologia 59, no. 1A (2022): 07015. http://dx.doi.org/10.1088/0026-1394/59/1a/07015.

Full text
Abstract:
Main text This report describes the results of a key comparison among hydraulic high pressure standards that have been maintained by seven National Metrology Institutes (NMIs: NIMT, NMIJ/AIST, NPLI, RCM-LIPI, NMIM, VMI and NMLPHIL). This comparison was carried out during the period March 2016 to October 2017 within the framework of the Asia-Pacific Metrology Programme (APMP) in order to determine their degrees of equivalence in the pressure range from 10 MPa to 100 MPa, gauge mode. The pilot institute was the National Institute of Metrology (Thailand) (NIMT). All participating institutes used
APA, Harvard, Vancouver, ISO, and other styles
6

Worden, Ray D. "Advanced Design Concepts for Fused Quartz Pressure Transducers." Measurement and Control 20, no. 9 (1987): 51–55. http://dx.doi.org/10.1177/002029408702000902.

Full text
Abstract:
The author presents the engineering design considerations applied in the development of a laboratory grade pressure standard utilising a fused quartz Bourdon tube transducer, and its adaptation to uses in field service and process control industries.
APA, Harvard, Vancouver, ISO, and other styles
7

Bansil, M. S., and F. Abdullah. "Finite element modelling of Bourdon tubes used in pressure and temperature gauges." Transactions of the Institute of Measurement and Control 7, no. 4 (1985): 203–8. http://dx.doi.org/10.1177/014233128500700404.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

FUKAKURA, Juichi, Hiroshige ITOH, Masanori ISHIMATU, and Kenji OHBA. "Fatigue Life Assessment of Bourdon Tube against Cyclic Internal Pressure." Transactions of the Japan Society of Mechanical Engineers Series A 62, no. 599 (1996): 1535–42. http://dx.doi.org/10.1299/kikaia.62.1535.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Biggar, Joshua. "An Uncertainty Analysis of Fused-Quartz Bourdon Tube Pressure Instruments." NCSLI Measure 8, no. 4 (2013): 45–51. http://dx.doi.org/10.1080/19315775.2013.11721663.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Azooz, R. H., and M. A. Arshad. "Laboratory calibration of pressure transducer-tensiometer system for hydraulic studies." Canadian Journal of Soil Science 74, no. 3 (1994): 315–19. http://dx.doi.org/10.4141/cjss94-044.

Full text
Abstract:
Pressure transducer-tensiometer (PTT) systems can be used to continuously monitor soil pore water pressure and the hydraulic gradient distribution in a field, and under laboratory conditions over relatively short time intervals. A reliable laboratory calibration of a PTT system can determine the effects of temperature fluctuations on output readings in the field. Laboratory calibrations of 20 PTTs were conducted under constant pressures of 0, − 25, − 50 and − 75 kPa and constant temperatures of 5, 15, 25 and 48 °C. Twenty Bourdon gauge tensiometers (BGTs) and pressure transducers (PTs) were al
APA, Harvard, Vancouver, ISO, and other styles
More sources

Dissertations / Theses on the topic "Bourdon Tube Pressure Gauge"

1

Iano, Marcos Chogi. "Analise dos efeitos da temperatura e do tempo de utilização em elementos sensores tipo tubo de Bourdon." [s.n.], 2009. http://repositorio.unicamp.br/jspui/handle/REPOSIP/263354.

Full text
Abstract:
Orientador: Kamal Abdel Radi Ismail<br>Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica<br>Made available in DSpace on 2018-08-14T07:39:10Z (GMT). No. of bitstreams: 1 Iano_MarcosChogi_D.pdf: 40621209 bytes, checksum: d971e987a0e70601a78ccb0bd1587e8e (MD5) Previous issue date: 2009<br>Resumo: Instrumentos de monitoramento como termômetros, multímetros, voltímetros, manômetros, etc, são imprescindíveis para o controle e confiabilidade de um processo. No entanto, não muito raramente, os cuidados para o perfeito funcionamento destes instrumentos são colocad
APA, Harvard, Vancouver, ISO, and other styles

Book chapters on the topic "Bourdon Tube Pressure Gauge"

1

Jiao, M. X., E. G. Zhao, Y. M. Liu, and R. L. Qi. "A High Sensitivity Pressure Sensing System with Fiber Bragg Grating Using the Transverse Strain Characteristics of a Straight Bourdon Tube." In Key Engineering Materials. Trans Tech Publications Ltd., 2005. http://dx.doi.org/10.4028/0-87849-977-6.539.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Sidoti, Paul A. "Early Hypotony." In Complications of Glaucoma Surgery. Oxford University Press, 2013. http://dx.doi.org/10.1093/oso/9780195382365.003.0055.

Full text
Abstract:
Ocular hypotony in the early postoperative period following tube shunt surgery is relatively common. The pressure level at which structural compromise of the eye and resultant secondary complications (e.g., shallow/ flat anterior chamber, serous and/or hemorrhagic choroidal detachment, chorioretinal folds, corneal folds) occur varies considerably. Some patients may tolerate extremely low pressures well for extended periods of time. However, an increased amount of secondary complications is often seen with intraocular pressures (IOPs) below 6 mm Hg. For the purpose of the ensuing discussion, we
APA, Harvard, Vancouver, ISO, and other styles
3

Shao, J., Z. Jia, J. Liu, and X. Bai. "Analyzing the improved model of the Bourdon tube using a uniform strength cantilever beam FBG pressure sensor." In Material Science and Environmental Engineering. CRC Press, 2015. http://dx.doi.org/10.1201/b19346-97.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Piovanetti, Omar. "Tube Misdirection and Inadequate Tube Length." In Complications of Glaucoma Surgery. Oxford University Press, 2013. http://dx.doi.org/10.1093/oso/9780195382365.003.0050.

Full text
Abstract:
Tube misdirection and inadequate tube length are 2 problems commonly seen by glaucoma surgeons. These complications can occur at the time of surgery or develop years later. Understanding the underlying causes for these problems and techniques to prevent and manage these issues is critical for successful outcomes. Tube placed too anteriorly. During anterior chamber tube shunt implantation, a 23-gauge needle is commonly used to make entry into the anterior chamber. The tube is then inserted through this track into the space between the corneal and iris planes. For most surgeons the anterior cham
APA, Harvard, Vancouver, ISO, and other styles
5

Chen, Philip P. "Obstruction of the Tube/Valve." In Complications of Glaucoma Surgery. Oxford University Press, 2013. http://dx.doi.org/10.1093/oso/9780195382365.003.0058.

Full text
Abstract:
Tube shunt obstruction is a relatively common complication, with reported rates up to 15%. Tube obstructions can be divided into 2 basic types: 1) distal tube obstruction in the anterior chamber, ciliary sulcus, or pars plana; and 2) proximal tube obstruction at the tubeplate junction. Occasionally tube obstruction may lead the surgeon and patient to believe that the tube shunt was never successful at controlling intraocular pressure (IOP) postoperatively. This complication generally has a high impact on the patient’s postoperative course. Preoperative planning and careful surgical technique c
APA, Harvard, Vancouver, ISO, and other styles
6

Magee, Patrick, and Mark Tooley. "Gas pressure, Volume and Flow Measurement." In The Physics, Clinical Measurement and Equipment of Anaesthetic Practice for the FRCA. Oxford University Press, 2011. http://dx.doi.org/10.1093/oso/9780199595150.003.0018.

Full text
Abstract:
The physics of pressure, flow and the gas laws have been discussed in Chapter 7 in relation to the behaviour of gas and vapour. This section will focus on the physical principles of the measurement of gas pressure, volume and flow. Unlike a liquid, a gas is compressible and the relationship between pressure, volume and flow depends on the resistance to gas flow (or impedance if there is a frequency dependence between pressure and flow in alternating flow, see Chapter 4 for the electrical analogy of this) in conduits (bronchi, anaesthetic tubing); it also depends on the compliance of structures
APA, Harvard, Vancouver, ISO, and other styles
7

Jamshed, Shamoon. "A Brief Review of Techniques of Thermal Enhancement in Tubes." In Heat Transfer - Advances in Fundamentals and Applications [Working Title]. IntechOpen, 2023. http://dx.doi.org/10.5772/intechopen.113134.

Full text
Abstract:
Heat transfer enhancement in tubes is not a novel idea. These tubes are used in several engineering devices like heat exchangers, boilers, evaporators, refrigerators, and air conditioners, to name a few. To date, these tubes are undergoing an evolutionary period, since engineers are trying new ways to improve the heat transfer (or enhance the heat transfer). The main cause is the pressure loss that occurs due to friction and the limitation of the surface area of the tube. The passive techniques to overcome this loss are more common due to cost-effectiveness. Thus, common passive techniques inc
APA, Harvard, Vancouver, ISO, and other styles

Conference papers on the topic "Bourdon Tube Pressure Gauge"

1

Saha, Sirshendu, Hiranmoy Mandal, Samrat Das, and Satish Chandra Bera. "Study of a Bourdon Tube-Hall Sensor Based Non-Contact Smart Pressure Transmitter." In 2024 4th International Conference on Computer, Communication, Control & Information Technology (C3IT). IEEE, 2024. https://doi.org/10.1109/c3it60531.2024.10829481.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Mondal, Bikas, Joyanta Kumar Roy, Nirupama Mondal, and Rajan Sarkar. "An approach to design a Bourdon tube pressure transmitter for remote measurement." In 2016 10th International Conference on Sensing Technology (ICST). IEEE, 2016. http://dx.doi.org/10.1109/icsenst.2016.7796254.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Liu, Xiaohui, Wenan Zhao, Qingchao Zhao, et al. "Fiber Optic Pressure and Temperature Sensor with Bourdon Tube for Downhole Application." In Asia-Pacific Optical Sensors Conference. OSA, 2016. http://dx.doi.org/10.1364/apos.2016.th4a.33.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Biggar, Joshua. "An Uncertainty Analysis of Fluke Calibration Fused-Quartz Bourdon Tube Pressure Products." In NCSL International Workshop & Symposium. NCSL International, 2013. http://dx.doi.org/10.51843/wsproceedings.2013.39.

Full text
Abstract:
The forced-balanced fused-quartz Bourdon tube (QBT) technology is a proven pressure measurement method, which has been used in the metrology field for over 50 years. In the summer of 2010, Fluke Calibration acquired Ruska Instrument Corporation from General Electric’s Sensing and Technologies division which added this unique, high-performance pressure measurement technology to the Fluke Calibration family of pressure products. The celebrated pedigrees in Fluke Calibration’s pressure coterie that employ QBT technology are the 7000 Series pressure products. 7000 Series pressure controllers and i
APA, Harvard, Vancouver, ISO, and other styles
5

Srimannarayana, K., P. Vengal Rao, M. Sai Shankar, and P. Kishore. "FBG sensor for temperature-independent high sensitive pressure measurement with aid of a Bourdon tube." In SPIE Photonics Europe, edited by Francis Berghmans, Anna G. Mignani, and Piet De Moor. SPIE, 2014. http://dx.doi.org/10.1117/12.2052908.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Hurrell, P. R., N. A. Leggatt, and R. J. Dennis. "Residual Stress Analysis of Tube Attachment Weld in Pressure Vessel Forging: Comparison of FE Predictions and Measurements." In ASME 2005 Pressure Vessels and Piping Conference. ASMEDC, 2005. http://dx.doi.org/10.1115/pvp2005-71315.

Full text
Abstract:
Residual stresses were analysed in a partial penetration weld attaching a tube inside a thick pressure vessel forging, both made of SA508 steel. 2D finite element (FE) analyses methods were used to simulate this multi-pass manual TIG weld. The weld preps are buttered and the forging subsequently heat-treated prior to making the closure weld. Buttering of the forging J-prep and subsequent PWHT creep stress relaxation were modelled. Generally the buttering was found to have minimal influence on the final stress state, although some difference in local peak stress and stress gradients were calcul
APA, Harvard, Vancouver, ISO, and other styles
7

Lee, Gary Y. H., Ohgeon Kwon, Zuwairi Ramli, and Zaki Mohamad Afifi. "Crude Furnace Creep Assessment and High Temperature Degradation." In ASME 2017 Pressure Vessels and Piping Conference. American Society of Mechanical Engineers, 2017. http://dx.doi.org/10.1115/pvp2017-65046.

Full text
Abstract:
Creep calculations indicate a crude furnace radiant section carbon steel tubes exceeding their life fraction due to flame impingement reaching up to 700°C for a year. The ambiguity of the temperature and material data means the life fraction of creep calculations were based on limited inspection data and infra-red scanning giving a conservative indication of end of life. Due to unavailable tubes in stock, a planned pit stop cannot be arranged due to economic and safety reasons as the furnace may not be started back up safely. To safeguard the integrity of the furnace until the planned outage,
APA, Harvard, Vancouver, ISO, and other styles
8

Whaley, Kevin, Tahir Tahirov, Sherine Khedr, et al. "A Critical Review of Shunt Tube Deployed Open Hole Gravel Pack Completions Pumped with no Positive Surface Pressure." In SPE Annual Technical Conference and Exhibition. SPE, 2022. http://dx.doi.org/10.2118/210121-ms.

Full text
Abstract:
Abstract Shunt tube deployed Open Hole Gravel Pack (OHGP) completions have been installed in the industry for about 25 years and have become widely recognized as a very reliable sand control completion technique. Some of these shunt tube gravel pack operations, are pumped with no positive surface treating pressure for a long duration of the packing operation. This paper will discuss in detail the system hydraulics and shunt tube packing process in these types of operation. The paper will review the surface and down hole gauge pumping data from a suite of shunt tube gravel packs which were pump
APA, Harvard, Vancouver, ISO, and other styles
9

Davies, M. R. D., J. E. Fitzgerald, J. T. Duffy, and F. K. O’Donnell. "Measurements of Aerodynamic Wall Shear Stress With Heated Thin Film Gauges." In ASME 1997 International Gas Turbine and Aeroengine Congress and Exhibition. American Society of Mechanical Engineers, 1997. http://dx.doi.org/10.1115/97-gt-211.

Full text
Abstract:
Previous publications have demonstrated the method of heated thin film gauge aerodynamic wall shear stress calibration in a laminar flow with a favourable free stream pressure gradient. Further evidence, derived from calibrating a gauge in laminar pipe flow and flow over a wedge, supports both the format of the calibrating equation and the value of the calibration constants. The pipe flow calibration is extended into turbulent flow and it is shown that the format of the calibrating equatinn remains unchanged whilst the value of the first constant changes markedly. The calibration constants are
APA, Harvard, Vancouver, ISO, and other styles
10

Cowper, Bruce, and Zachary Schramm. "Shafting Systems without a Forward Stern Tube Bearing: Advantages and Prevention of Failures." In SNAME 15th Propeller and Shafting Symposium. SNAME, 2018. http://dx.doi.org/10.5957/pss-2018-08.

Full text
Abstract:
In recent years shafting systems, particularly those powered by slow-speed diesel engines, have been designed with only one bearing supporting the propeller shaft (typically an aft stern tube bearing). Designs with only one stern tube bearing provide for a system with more flexibility, easier installation, and a reduction in cost. With no forward stern tube bearing, there are different alignment characteristics that must be considered. Of importance is the significant effect of the aft intermediate shaft bearing position on the relative shaft slope in-way-of the aft stern tube bearing. The lin
APA, Harvard, Vancouver, ISO, and other styles

Reports on the topic "Bourdon Tube Pressure Gauge"

1

Zuo, Xiqing, Guowen Liu, Shouli Zhang, Sheng Li, and Jian Ruan. Design and Characteristics Analysis of Bourdon Tube Pressure Feedback for 2D Pressure Servo Valve. "Prof. Marin Drinov" Publishing House of Bulgarian Academy of Sciences, 2018. http://dx.doi.org/10.7546/crabs.2018.01.13.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Zuo, Xiqing, Guowen Liu, Shouli Zhang, Sheng Li, and Jian Ruan. Design and Characteristics Analysis of Bourdon Tube Pressure Feedback for 2D Pressure Servo Valve. "Prof. Marin Drinov" Publishing House of Bulgarian Academy of Sciences, 2018. http://dx.doi.org/10.7546/grabs2018.1.13.

Full text
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!