Academic literature on the topic 'Buttress plate fixation'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Buttress plate fixation.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "Buttress plate fixation"

1

WANG, YU-TZU, PO-FANG WANG, CHIEN-TZUNG CHEN, CHIH-HAO CHEN, and CHUN-LI LIN. "BIOMECHANICAL ANALYSIS TO VERIFY THE BUTTRESS THEORY WHEN USING THE ANATOMICAL THIN TITANIUM MESH PLATE FOR ZYGOMATICOMAXILLARY COMPLEX BONE FRACTURE." Journal of Mechanics in Medicine and Biology 19, no. 02 (2019): 1940025. http://dx.doi.org/10.1142/s0219519419400256.

Full text
Abstract:
Objective: The aim of this study was to investigate the biomechanics of the facial skeletal for understanding the buttress after fixation with standard and modified anatomical thin titanium mesh (ATTM) plates by finite element (FE) analysis. Methods: Standard ATTM (SATTM) plate designed as the “L”-shape anticipated to be fixed in the ZMC anterior maxilla and lateral buttress to increase the fixation screw anchoring strength and another modified ATTM (MATTM) plate with a protrusion in the medial side and a slot and barb design in the lateral side to enhance the zygomaticomaxillary/nasomaxillary
APA, Harvard, Vancouver, ISO, and other styles
2

Pease, F., AJ Ward, AJ Stevenson, et al. "Posterior wall acetabular fracture fixation: A mechanical analysis of fixation methods." Journal of Orthopaedic Surgery 27, no. 3 (2019): 230949901985983. http://dx.doi.org/10.1177/2309499019859838.

Full text
Abstract:
Stable, anatomical fixation of acetabular fractures gives the best chance of successful outcome, while penetration of the acetabular articular surface with screws is associated with poor outcomes. Spring plates are an alternative to interfragmentary lag screws when penetration is a concern. A mechanical study comparing fracture stability and construct stiffness of three fixation methods for posterior wall acetabular fractures with transverse comminutions was performed. The three fixation methods tested were a posterior wall rim plate, a posterior wall buttress plate with separate lag screws an
APA, Harvard, Vancouver, ISO, and other styles
3

Deependra, Sonkar, Tandon Suneet, Pathak Abhishek, and Patidar Neeraj. "Evaluating the Efficacy: Lag Screw vs. Buttress Plate Fixation in Posterior Malleolar Fractures." International Journal of Pharmaceutical and Clinical Research 16, no. 6 (2024): 1002–5. https://doi.org/10.5281/zenodo.12738839.

Full text
Abstract:
<strong>Background:</strong>&nbsp;Effective surgical management is crucial for optimal outcomes in posterior malleolar fractures. This study compares the efficacy of lag screw versus buttress plate fixation techniques in treating these fractures.&nbsp;<strong>Aim and Objective:</strong>&nbsp;To compare the efficacy of lag screw versus buttress plate fixation in treating these fractures.&nbsp;<strong>Methods and Methods:</strong>&nbsp;In this prospective randomized controlled trial, 40 patients with posterior malleolar fractures were assigned to either lag screw fixation (n=20) or buttress plat
APA, Harvard, Vancouver, ISO, and other styles
4

Dar, Usman Zafar, Ali Muqaddas, Mohammad Nauman Shahid, Muhammad Ahmed, Sameer Ahmed, and Naeem Hussain. "Posteromedial Buttress Plate for Schatzker 6 Fractures as Double Column Fixation." Pakistan Journal of Medical and Health Sciences 17, no. 2 (2023): 543–45. http://dx.doi.org/10.53350/pjmhs2023172543.

Full text
Abstract:
Objective: Treatment of Schatzker Type 6 fractures is to use a posteromedial buttress plate as part of a double-column fixation technique. Materials &amp; Methods: The design of this study was a cross sectional study design and this study was conducted in DHQ Teaching Hospital Gujranwala. patients with posterior medial fracture of Schatzker type 6 and having associated damage of some soft tissue present within the joint underwent surgery at our institutional operation theatre. In this Study setting we included total 20 patients (14 male [70%] and 6 females [30%]) who came with Bicondylar fract
APA, Harvard, Vancouver, ISO, and other styles
5

Foo, Gen-Lin, Amit K. Ramruttun, Andre Eujin Cheah, Alphonsus Kin-Sze Chong, and Tun-Lin Foo. "Biomechanics of Internal Fixation Modalities for Middle Phalangeal Base Fracture Dislocation." Journal of Hand Surgery (Asian-Pacific Volume) 22, no. 01 (2017): 14–17. http://dx.doi.org/10.1142/s0218810417500022.

Full text
Abstract:
Background: Internal fixation modalities of unstable (&gt;50 percent articular involvement) middle phalangeal volar lip fracture-dislocations include interfragmentary screw and volar buttress plating. This study investigates the mechanical properties (yield strength, ultimate tensile strength, and stiffness) of interfragmentary screw (IS), simple buttress plating (BP) and buttress plating with subchondral screw (BP+S). Methods: Fifteen cadaveric digits (5 index, 5 middle, and 5 ring) were prepared by excising its skin envelope and flexor tendons while preserving the structures around the proxi
APA, Harvard, Vancouver, ISO, and other styles
6

Egli, R. J., M. J. B. Keel, J. L. Cullmann, and J. D. Bastian. "Secure Screw Placement in Management of Acetabular Fractures Using the Suprapectineal Quadrilateral Buttress Plate." BioMed Research International 2017 (2017): 1–7. http://dx.doi.org/10.1155/2017/8231301.

Full text
Abstract:
Acetabular fractures involving predominantly the anterior column associated with a disruption of the quadrilateral surface can be treated with instrumentation implementing the stabilization of the quadrilateral surface. The recently introduced suprapectineal quadrilateral buttress plate is specifically designed to prevent secondary medial subluxation of the femoral head, especially in elderly patients with reduced ability for partial weight bearing. Whereas there are guidelines available for safe screw fixation for the anterior and posterior columns, there might be a concern for intra-articula
APA, Harvard, Vancouver, ISO, and other styles
7

Lamichhane, Norman, Bhogendra Bahadur KC, Chandra Bahadur Mishra, and Sabita Dhakal. "Non-locking buttress plate in distal tibial metaphyseal fractures." Medical Journal of Pokhara Academy of Health Sciences 1, no. 2 (2018): 87–91. http://dx.doi.org/10.3126/mjpahs.v1i2.23401.

Full text
Abstract:
Background: Treatment of distal tibial metaphyseal fractures is often challenging and no single technique has been unanimously advocated. Open reduction and internal fixation with plates and screws allows better restoration of anatomical alignment but with more soft tissue complication. Simultaneous fixation of the fibula is not universally carried out. This study aims at evaluation of the outcome of plating technique and the effect of fixation of fibula fracture in treatment of distal tibial metaphyseal fractures.&#x0D; Material and methods: Thirty-one cases (14 cases in Group A with concomit
APA, Harvard, Vancouver, ISO, and other styles
8

Patil, Pavankumar H., and Srinivas Pamarathi. "Intra articular fracture of distal end of radius treated by open reduction and internal fixation with buttress plate-a clinical study." International Journal of Research in Orthopaedics 3, no. 3 (2017): 518. http://dx.doi.org/10.18203/issn.2455-4510.intjresorthop20171895.

Full text
Abstract:
&lt;p class="abstract"&gt;&lt;strong&gt;Background:&lt;/strong&gt; &lt;span lang="EN-IN"&gt;Recognition of fracture patterns and fixation of fracture to secure and maintain reduction is the key for successful management of more complex intra articular fractures of distal radius. Devices like buttress plates have been shown to provide excellent stability for an unstable fracture with either dorsal or volar metaphyseal comminution. The objective of the study was to evaluate the functional outcome of intra articular fracture of distal end of radius treated by open reduction and internal fixation
APA, Harvard, Vancouver, ISO, and other styles
9

Murayama, Atsuhiko, Kentaro Watanabe, Hideyuki Ota, Shigeru Kurimoto, and Hitoshi Hirata. "Volar plating versus external fixation for unstable dorsal fracture-dislocations of the proximal interphalangeal joint." Journal of Hand Surgery (European Volume) 47, no. 3 (2021): 308–13. http://dx.doi.org/10.1177/17531934211059300.

Full text
Abstract:
We retrospectively compared the results of volar plating and dynamic external fixation for acute unstable dorsal fracture-dislocations of the proximal interphalangeal joint with a depressed fragment. We treated 31 patients (31 fingers), 12 with volar buttress plating and 19 with dynamic external fixation. Follow-up averaged 35 and 40 months in the two groups, with a minimal 6-month follow-up. Average active flexion of the proximal interphalangeal joint was 95° after plate fixation and 87° after external fixation, with an active extension lag of –6° and –9°, respectively. Active flexion at the
APA, Harvard, Vancouver, ISO, and other styles
10

Keyur, Rajendrakumar Shah, and A. Patel Kamaleshkumar. "Study on the Functional Outcome of the Distal End of Radius Fractures Treated with Buttress Plating." International Journal of Pharmaceutical and Clinical Research 15, no. 8 (2023): 1258–64. https://doi.org/10.5281/zenodo.11521557.

Full text
Abstract:
<strong>Introduction:&nbsp;</strong>This following study examines distal radius fracture care, the most common upper extremity injury in the US. More than 300,000 fractures occur annually. Volar buttress plating is a popular method for treating unstable fractures due to its longevity and stability. Both Kirschner-wire and locking plates have pros and cons. The effects of the 2.7-mm volar locking plate have not been extensively studied despite multiple plating operations. Distal radial fracture treatment in the elderly is poorly researched.&nbsp;<strong>Aims and Objectives:</strong>&nbsp;This s
APA, Harvard, Vancouver, ISO, and other styles
More sources
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!