Academic literature on the topic 'Calibration Case Study'
Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles
Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Calibration Case Study.'
Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.
You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.
Journal articles on the topic "Calibration Case Study"
Toledo, Tomer, Haris N. Koutsopoulos, Angus Davol, Moshe E. Ben-Akiva, Wilco Burghout, Ingmar Andréasson, Tobias Johansson, and Christen Lundin. "Calibration and Validation of Microscopic Traffic Simulation Tools: Stockholm Case Study." Transportation Research Record: Journal of the Transportation Research Board 1831, no. 1 (January 2003): 65–75. http://dx.doi.org/10.3141/1831-08.
Full textAcuña, Guillermo J., Humberto Ávila, and Fausto A. Canales. "River Model Calibration Based on Design of Experiments Theory. A Case Study: Meta River, Colombia." Water 11, no. 7 (July 5, 2019): 1382. http://dx.doi.org/10.3390/w11071382.
Full textHall, John J., and Robert L. Williams. "Case study: Inertial measurement unit calibration platform." Journal of Robotic Systems 17, no. 11 (November 2000): 623–32. http://dx.doi.org/10.1002/1097-4563(200011)17:11<623::aid-rob4>3.0.co;2-7.
Full textWalski, Thomas M. "Case Study: Pipe Network Model Calibration Issues." Journal of Water Resources Planning and Management 112, no. 2 (March 1986): 238–49. http://dx.doi.org/10.1061/(asce)0733-9496(1986)112:2(238).
Full textKim, Kangjoo, Mary P. Anderson, and Carl J. Bowser. "Model Calibration with Multiple Targets: A Case Study." Ground Water 37, no. 3 (May 1999): 345–51. http://dx.doi.org/10.1111/j.1745-6584.1999.tb01110.x.
Full textHolt, Robert W., Jeffrey T. Hansberger, and Deborah A. Boehm-Davis. "Improving Rater Calibration in Aviation: A Case Study." International Journal of Aviation Psychology 12, no. 3 (July 2002): 305–30. http://dx.doi.org/10.1207/s15327108ijap1203_7.
Full textParisi, Maria Adelaide, Mariapaola Riggio, Chiara Tardini, and Maurizio Piazza. "Rehabilitation of Timber Structures and Seismic Vulnerability: A Case Study." Advanced Materials Research 133-134 (October 2010): 741–46. http://dx.doi.org/10.4028/www.scientific.net/amr.133-134.741.
Full textEstienne, F., D. L. Massart, N. Zanier-Szydlowski, and Ph Marteau. "Multivariate calibration with Raman spectroscopic data: a case study." Analytica Chimica Acta 424, no. 2 (December 2000): 185–201. http://dx.doi.org/10.1016/s0003-2670(00)01107-7.
Full text., Falguni Baliarsingh. "REAL TIME RESERVOIR OPERATION (CALIBRATION PHASE): A CASE STUDY." International Journal of Research in Engineering and Technology 03, no. 09 (September 25, 2014): 239–51. http://dx.doi.org/10.15623/ijret.2014.0309037.
Full textParkinson, S., A. P. Longstaff, S. Fletcher, A. Crampton, and P. Gregory. "Automatic planning for machine tool calibration: A case study." Expert Systems with Applications 39, no. 13 (October 2012): 11367–77. http://dx.doi.org/10.1016/j.eswa.2012.03.054.
Full textDissertations / Theses on the topic "Calibration Case Study"
Ar, Kerem. "Calibration Of Water Distribution Networks." Master's thesis, METU, 2012. http://etd.lib.metu.edu.tr/upload/12613934/index.pdf.
Full textApaydin, Oncu. "Automated Calibration Of Water Distribution Networks." Master's thesis, METU, 2013. http://etd.lib.metu.edu.tr/upload/12615692/index.pdf.
Full textin this case study the network is calibrated on the basis of roughness parameter, Hazen Williams coefficient for the sake of simplicity. It is understood that there are various parameters that contribute to the uncertainties in water distribution network modelling and the calibration process. Besides, computer software&rsquo
s are valuable tools to solve water distribution network problems and to calibrate network models in an accurate and fast way using automated calibration technique. Furthermore, there are many important aspects that should be considered during automated calibration such as pipe roughness grouping. In this study, influence of flow velocity on pipe roughness grouping is examined. Roughness coefficients of pipes have been estimated in the range of 70-140.
Poon, Phillip, and Matthew Dunlop. "Calibration of High Dimensional Compressive Sensing Systems: A Case Study in Compressive Hyperspectral Imaging." International Foundation for Telemetering, 2013. http://hdl.handle.net/10150/579668.
Full textCompressive Sensing (CS) is a set of techniques that can faithfully acquire a signal from sub- Nyquist measurements, provided the class of signals have certain broadly-applicable properties. Reconstruction (or exploitation) of the signal from these sub-Nyquist measurements requires a forward model - knowledge of how the system maps signals to measurements. In high-dimensional CS systems, determination of this forward model via direct measurement of the system response to the complete set of impulse functions is impractical. In this paper, we will discuss the development of a parameterized forward model for the Adaptive, Feature-Specific Spectral Imaging Classifier (AFSSI-C), an experimental compressive spectral image classifier. This parameterized forward model drastically reduces the number of calibration measurements.
Kazemzadeh, Samimi Anahita. "Estimation of regional groundwater level through calibration of GRACE satellite data : A case study in southern half of Sweden." Thesis, Högskolan i Gävle, Avdelningen för Industriell utveckling, IT och Samhällsbyggnad, 2012. http://urn.kb.se/resolve?urn=urn:nbn:se:hig:diva-13634.
Full textAndersson, Sara. "Mapping Uncertainties – A case study on a hydraulic model of the river Voxnan." Thesis, KTH, Mark- och vattenteknik, 2015. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-173848.
Full textChatzakis, Alexandros. "Calibration of a 2D hydrodynamic model for flood inundation extent using aerial photographs : A case study of the Hallsberg flood event in 5-9 September 2015." Thesis, KTH, Vattendragsteknik, 2017. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-204901.
Full textÄndringar i nederbördsmönster är en tydlig konsekvens av klimatförändringen. Regnhändelser med stora volymer nederbörd under korta tidsperioder förutses bli alltmer frekventa i regioner vid högre breddgrader, däribland Sverige. Ett karaktäristiskt exempel av en sådan händelse skedde mellan den femte och sjätte september 2015 i Hallsberg. Ca 105 mm regn föll inom loppet av 24 timmar vilket orsakade stora översvämningar i staden. För att kunna förutse översvämningar så som den tidigare nämnd och möjliggöra vidtagning av förebyggande åtgärder används hydrodynamiska modeller för att simulera vattenflöden och undersöka möjliga scenarion av nederbörd. Emellertid, på grund av avsaknaden av data för kalibrering av modellerna medför användandet av dem en signifikant osäkerhet. Syftet med den här rapporten är att undersöka översvämningen i Hallsberg i september 2015 genom att kalibrera en hydrodynamisk modell med hjälp av flygbilder för översvämningens utbredning. Den använda modellen, MIKE 21, är en 2D modell över ytavrinningen utvecklad av DHI. Praxis vid studiet av översvämningar är att inkludera infiltrationsförmåga med ett godtyckligt avdrag av nederbörden. Här används istället infiltreringsmodulen för MIKE 21, vilket är en ny del som har utvecklats i modellen. Förutom översvämningens utbredning utvärderades även resultaten utifrån vattendjupet vid två punkter baseras på ett fotografi från gatorna i det drabbade området. Utvärdering av resultaten gjordes också mot tid av översvämnings kulm från beskrivning av händelses förlopp samt vattenvolym vid pixlarna som felaktigt simulerades som översvämmade. Resultatet visade på en hög grad av samstämmighet med gjorda observationer. Parametern ytans råhet, uttryckt som Mannings ”M”, visade sig vara av stor betydelse med lämpliga värden för underutvecklade områden under 5. Därtill spelade kulvertarnas begränsade kapacitet en viktig roll vid översvämmandet av staden. Att inkludera dessa i simuleringarna var därför avgörande. Slutligen, användandet av infiltreringsmodulen resulterade i en högre noggrannhet av 8.3 %, även om det kan anses vara ett godtyckligt vattenavdrag då vissa av de använda parametrarna inte är fysiskt välmotiverade.
Le, Maître Johann. "Développement de la spectrométrie de masse à ultra- haute résolution associée à la spectrométrie de mobilité ionique pour la caractérisation de coupes pétrolières lourdes. structural analysis of heavy oil fractions afterr hydrodenitrogenation by high-resolution tandem mass spectrometry and ion mobility spectrometry Structural analysis of neutral nitrogen compounds refractory to the hydrodenitrogenation process of heavy oil fractions by high-resolution tandem mass spectrometry and ion mobility-mass spectrometry Chemical characterization of 15 biocrudes obtained from hydrothermal liquefaction of industrially cultivated wild micro algae Chemical characterization with different analytical techniques, a way to understand the process: Case of the paraffinic base oil production line Exploring complex mixtures by cyclic ion mobility high-resolution mass spectrometry – Application towards Petroleum. Simulation and modeling of Collision Cross Section for structural elucidation of heavy oil fraction by ion mobility-mass spectrometry: Using polyaromatic hydrocarbons compounds mixture as calibration standard Characterization of sulfoxides compounds in dimeric distribution of heavy oil fractions by positive-ion electrospray ionization FTICR mass spectrometry Structural analysis of Petroporphyrins from asphaltene by trapped ion mobility coupled with a Fourier transform ion cyclotron resonance mass spectrometer. Cyclic ion mobility spectrometry coupled to high-resolution time-of-flight mass spectrometry equipped with atmospheric solid analysis probe for the molecular characterization of combustion particulate matter. Structural study of analogues of Titan’s haze by trapped ion mobility coupled with a Fourier transform ion cyclotron mass spectrometer." Thesis, Normandie, 2020. http://www.theses.fr/2020NORMR051.
Full textThe evolution of oil reserves requires the use in refineries of unconventional crude oils, which are often heavier and therefore difficult to characterize. Petroleum products are in fact extremely complex chemical mixtures. The light and volatile part can be analysed by gas chromatography coupled with mass spectrometry (GC/MS), allowing the identification of compounds by using precise mass measurements and fragmentation models. However, these techniques are inappropriate for the analysis of heavy fractions. In practice, the characterization of the most complex mixtures involves the use of ultra-high-resolution mass spectrometers generally by direct analysis without chromatographic separation. The reference technique today is Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (FTICR). With a resolution of more than 106 and a mass measurement accuracy of less than 0.1 ppm, this instrument can separate all the species present in a petroleum product and assign a unique elemental composition to each m/z value. This makes it very easy to obtain molecular maps that can be presented graphically using the Kendrick diagram, the van Krevelen diagram or the number of unsaturations (DBE) as a function of the number of carbons. This thesis work has allowed thanks to the molecular characterization of petroleum products (Vacuum Gas Oil, Crude Oil, Interfacial Material, Asphaltenes and Bio-Oil...) addressing the complexity of their treatment in the refining tool. Protocols for sample analysis have been developed, using different sources of ionization at atmospheric pressure (ESI, APCI and APPI) as well as laser desorption/ionization (LDI) on the FTICR 12T mass spectrometer. Information on the isomeric content of petroleum products was then determined using ion mobility spectrometry (IMS)
Chung, Hsiu Hsuan, and 鍾秀瑄. "Calibration laboratory selection study--A case study of semiconductor assembly." Thesis, 2016. http://ndltd.ncl.edu.tw/handle/m5r773.
Full text國立清華大學
工業工程與工程管理學系碩士在職專班
104
The purpose of this study is to identify the key third-party calibration laboratory selection criteria for the semiconductor assembly and test company in Taiwan. Literature on calibration laboratory selection, that considers several matters such as professionalism, calibration fee, uncertainty, are relatively limited. However, both international standards and company’s customers have required that all gauges, measuring instrument should provide calibration activity record to provide evidence of conformity to product requirement. The value of this research provides a systematic laboratory selection model. Initially, identifying the critical criteria and classifying the quality attribute by the fuzzy Delphi method and Fuzzy Kano model separately. In the second phase, calculate the important weight of criteria by the AHP. Finally, ranking qualified calibration laboratory by the VIKOR. Creating a procurement contract with a filtered and qualified calibration laboratory to reduce the annual calibration cost. In addition, it not only can complete periodic calibration to avoid auditing finding but also ensure the accuracy of instrument to avoid unnecessary customer complaint. The proposed approach has also been examined by a case study. The research result shows that must-be attribute is the most important criterion group. At the detailed sub-criteria level, instrument capability, specialize knowledge, calibration fee, send and receive service and laboratory management are the top five criteria. Therefore, the decision-makers have shown much concern for accuracy and resolution of standard unit, standard unit maintenance and calibration record, lab staff’s technical and quality management skills, reasonable calibration fee and send/receive service.
Li, Jiun-han, and 李郡漢. "A Case Study for the Development Strategy in Instrument Calibration Industry." Thesis, 2006. http://ndltd.ncl.edu.tw/handle/u7tr23.
Full text國立臺灣科技大學
工業管理系
94
Any Industry during the process of researching and developing the products,or making,designing products,or at the stage of testing,will not guarantee the quality of the products unless it relies on the monitoring and the quantity of the precision instrument to examine it’s products。And technology of the instrument corrected especially guarantees the accuracy of the instrument。It has also been proved that the industry that corrects instrument has close relations with the development of the hi-tech industry。In order to have a clear understanding of prospect of the Industry that corrects instrument this research is to do deep discussion about it with the title of future development tactics of the industry that corrects instrument。 This research is to point out the change and the threat which the whole industry environment brought toward the industry that corrects instrument,to analyze the chance and threat by means the case company inside and outside。Because there are so many competitors of correcting industry of the instrument and they face the great changeable environment,these competitors must face the question of making the transition by themselves。The solution is that through developing new verification,calibration technology and establishing the researching-developing group,the competitors can make the transition and make measuring platforms to set up technology,and to become diversified measuring–correcting laboratories and to become the groups which design and produce key spare parts。This development tactics have already become the key point with which the unit of correcting industry of the instrument can get the current situation made transition and succeed。In order to solve the current problem of he case enterprise,this research sets about from the company’s mission and management tactics in order to understand and analyze the future thrust of the case company,and to probe into the development tactics in the future,to enable case enterprises to have one criterion to use on solving problems 。Finally,this research also proposes the suggestion on other same trades,and makes them get a clear reference directions。
Tsai, Yu-Min, and 蔡育旻. "Service expectation and cognition: A case study of SGS calibration laboratory." Thesis, 2010. http://ndltd.ncl.edu.tw/handle/98365482916299503636.
Full textBook chapters on the topic "Calibration Case Study"
Tavares Neto, Roberto, and Fabio Molina da Silva. "Scheduling Simultaneous Resources: A Case Study on a Calibration Laboratory." In Hybrid Metaheuristics, 150–63. Cham: Springer International Publishing, 2018. http://dx.doi.org/10.1007/978-3-030-05983-5_11.
Full textGraybill, Philip, Eyob Tarekegn, Ian Tomkinson, Kendra Van Buren, François Hemez, and Scott Cogan. "A Case Study in Predictive Modeling Beyond the Calibration Domain." In Model Validation and Uncertainty Quantification, Volume 3, 29–37. Cham: Springer International Publishing, 2017. http://dx.doi.org/10.1007/978-3-319-54858-6_4.
Full textGrejner-Brzezinska, Dorota A., Niyazi Arslan, Pawel Wielgosz, and Chang-Ki Hong. "Network Calibration for Unfavorable Reference-Rover Geometry in Network-Based RTK: Ohio CORS Case Study." In CORS and OPUS for Engineers, 143–53. Reston, VA: American Society of Civil Engineers, 2011. http://dx.doi.org/10.1061/9780784411643.ch18.
Full textde Oliveira, Antonio Krishnamurti Beleño, Osvaldo Moura Rezende, Matheus Martins de Sousa, and Marcelo Gomes Miguez. "An Alternative Model Calibration Strategy for Watersheds Lacking Proper Data Records: Case Study of Riohacha, Colombia." In New Trends in Urban Drainage Modelling, 746–51. Cham: Springer International Publishing, 2018. http://dx.doi.org/10.1007/978-3-319-99867-1_129.
Full textChui, Q. S. H., R. R. Zucchini, and J. Lichtig. "The Importance of Assessing Uncertainties Related to Linear Calibration Curves: A Case Study for Flame Atomic Absorption Spectrometry." In Environmental Geochemistry in Tropical and Subtropical Environments, 69–80. Berlin, Heidelberg: Springer Berlin Heidelberg, 2004. http://dx.doi.org/10.1007/978-3-662-07060-4_6.
Full textDi Nardo, Armado, Michele Di Natale, Anna Di Mauro, Giovanni Francesco Santonastaso, Andrea Palomba, and Stefano Locoratolo. "Calibration of a Water Distribution Network with Limited Field Measures: The Case Study of Castellammare di Stabia (Naples, Italy)." In Lecture Notes in Computer Science, 433–36. Cham: Springer International Publishing, 2018. http://dx.doi.org/10.1007/978-3-030-05348-2_36.
Full textLovreglio, Ruggiero, Charitha Dias, Xiang Song, and Lucia Ballerini. "Towards Microscopic Calibration of Pedestrian Simulation Models Using Open Trajectory Datasets: The Case Study of the Edinburgh Informatics Forum." In Traffic and Granular Flow '17, 215–23. Cham: Springer International Publishing, 2019. http://dx.doi.org/10.1007/978-3-030-11440-4_25.
Full textMahanta, Rupam, and R. K. Ghanekar. "Site-Specific Calibration of Nkt and N∆u Factors for Interpretation of Cone Penetration Test for Offshore Sites: A Case Study." In Lecture Notes in Civil Engineering, 123–35. Singapore: Springer Singapore, 2020. http://dx.doi.org/10.1007/978-981-15-6086-6_10.
Full textMichelet, Sandra, Vanda Luengo, Jean-Michel Adam, and Nadine Mandran. "Experimentation and Results for Calibrating Automatic Diagnosis Belief Linked to Problem Solving Modalities: A Case Study in Electricity." In Sustaining TEL: From Innovation to Learning and Practice, 408–13. Berlin, Heidelberg: Springer Berlin Heidelberg, 2010. http://dx.doi.org/10.1007/978-3-642-16020-2_29.
Full text"Calibration of concrete laboratories. Case study from Libya." In Test Quality for Construction, Materials and Structures, 109–14. CRC Press, 1990. http://dx.doi.org/10.1201/9781482267525-20.
Full textConference papers on the topic "Calibration Case Study"
Mariano, Andre, and Francois Rivet. "Calibration requires calibration, a case study: Mixed-signal BISC Time-Interleaved ADC." In 2012 IEEE 10th International New Circuits and Systems Conference (NEWCAS). IEEE, 2012. http://dx.doi.org/10.1109/newcas.2012.6329032.
Full textChang, Hsiu-Ming, Kuan-Yu Lin, and Kwang-Ting Cheng. "Calibration as a Functional Test: An ADC Case Study." In 2009 Asian Test Symposium. IEEE, 2009. http://dx.doi.org/10.1109/ats.2009.25.
Full textLippai, Istvan. "Colorado Springs Utilities Case Study: Water System Calibration / Optimization." In Pipeline Division Specialty Conference 2005. Reston, VA: American Society of Civil Engineers, 2005. http://dx.doi.org/10.1061/40800(180)84.
Full textYue -Yun Wang. "Model-based calibration: A case study for calibrating control systems of downsized boosted engines." In 2015 American Control Conference (ACC). IEEE, 2015. http://dx.doi.org/10.1109/acc.2015.7171044.
Full textSuroso, Irene, and Polly Boissevain. "Using Tracer Field Testing for Model Calibration: A Case Study." In 12th Annual Conference on Water Distribution Systems Analysis (WDSA). Reston, VA: American Society of Civil Engineers, 2011. http://dx.doi.org/10.1061/41203(425)69.
Full textGhosh, Sanjib K., and Mohamed Bougouss. "On-The-Job Calibration Of Tomodensitometric Systems - A Case Study." In Biostereometrics '88: Fifth Intl Mtg, edited by Juerg U. Baumann and Robin E. Herron. SPIE, 1989. http://dx.doi.org/10.1117/12.950483.
Full textDawidowicz, Karol, Grzegorz Krzan, Radosław Baryła, and Krzysztof Swiatek. "The Impact of GNSS Antenna Mounting during Absolute Field Calibration on Phase Center Correction – JAV_GRANT-G3T Antenna Case Study." In Environmental Engineering. VGTU Technika, 2017. http://dx.doi.org/10.3846/enviro.2017.183.
Full textDervisoglu, Gunes, Alexander Kurzhanskiy, Gabriel Gomes, and Roberto Horowitz. "Macroscopic freeway model calibration with partially observed data, a case study." In 2014 American Control Conference - ACC 2014. IEEE, 2014. http://dx.doi.org/10.1109/acc.2014.6859026.
Full textCan Polat, Halis, Veysel Okan Atak, Ismail Ergun Kocabicak Turkish, Emrah Gurcay, Fatih Guven Gultekin, and Erhan Erdi Yanteri. "Satellite Imagery Calibration and Quality Assessment Tests: GÖKTÜRK-L Case Study." In 2019 9th International Conference on Recent Advances in Space Technologies (RAST). IEEE, 2019. http://dx.doi.org/10.1109/rast.2019.8767436.
Full textFulton, C., and W. Chappell. "Calibration of panelized polarimetric phased array radar antennas: A case study." In 2010 IEEE International Symposium on Phased Array Systems and Technology (ARRAY 2010). IEEE, 2010. http://dx.doi.org/10.1109/array.2010.5613262.
Full text