To see the other types of publications on this topic, follow the link: Calibration of measuring equipment.

Journal articles on the topic 'Calibration of measuring equipment'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 50 journal articles for your research on the topic 'Calibration of measuring equipment.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse journal articles on a wide variety of disciplines and organise your bibliography correctly.

1

Hegeduš, Hrvoje, Marko Jurcevic, and Roman Malaric. "Internet-Enabled Calibration." International Journal of Measurement Technologies and Instrumentation Engineering 1, no. 1 (2011): 24–37. http://dx.doi.org/10.4018/ijmtie.2011010103.

Full text
Abstract:
Calibration of measuring instruments provides the confidence in measurements. It is the obligation of every laboratory to have its measuring equipment calibrated in regular intervals. This obligation means that the laboratory must send its equipment to the calibration laboratory every year or two depending on the calibration intervals. During this time the equipment is not available and this presents a financial burden to the laboratory of the customer. Since many of the modern instruments include some communication interfaces, it was made possible to create an Internet-enabled calibration sys
APA, Harvard, Vancouver, ISO, and other styles
2

Vasylieva, Olena, Yurii Pavlenko, and Valeriy Ogar. "Calibration complex of radio measuring equipment." Ukrainian Metrological Journal, no. 2 (June 25, 2024): 10–17. http://dx.doi.org/10.24027/2306-7039.2.2024.307137.

Full text
Abstract:
Modern trends in the development of radio measuring equipment require improvement of the principles of metrological support of these devices and corresponding reference base. The new approach is based on the digitalisation of equipment, programming of measurement procedures, and the transition from single measurement standards to measurement complexes. The paper describes the complex developed at the NSC “Institute of Metrology” and designed for verification and calibration of a wide range of radio measuring equipment, where all these approaches are realised, presents methodological, software
APA, Harvard, Vancouver, ISO, and other styles
3

Wang, Xiang Jun, Shu Zhang, Yi Liu, and Dou Ji. "The Electrochemical Principle of Measuring Underwater Electric Field." Applied Mechanics and Materials 232 (November 2012): 863–68. http://dx.doi.org/10.4028/www.scientific.net/amm.232.863.

Full text
Abstract:
Whether electric stealth ship, or ship by ship to achieve the electric field detection, location can’t be separated to provide high-precision measuring equipment field measured data, underwater electric field to discuss the principle of electrochemical measurements and underwater electric field measurement equipment calibration, field measurements of underwater deep understanding of electrochemical principles and calibration of measuring equipment underwater electric field can improve the accuracy of the electric field experiments, and finally according to proposed calibration method, calibrat
APA, Harvard, Vancouver, ISO, and other styles
4

Fidrovska, Nataliia, Roman Ponomarenko, Evgen Slepuzhnikov, and Dmytro Kozodoi. "JUSTIFICATION OF TENSORISTOR CALIBRATION IN A COMPLEX WITH MEASURING EQUIPMENT." Collected scientific works of Ukrainian State University of Railway Transport, no. 194 (October 5, 2021): 75–85. http://dx.doi.org/10.18664/1994-7852.194.2020.230411.

Full text
Abstract:
The article describes the process of calibrating strain gauge and measuring equipment. Modern machines have a complex design of the shapes of parts and assemblies. The loads acting on them often do not allow the determination of the stress state by modeling or calculation when creating these structurally complex machines. Therefore, conducting experimental studies using the strain gauge method is an extremely important task in real time. But for such a study, it is necessary to calibrate the strain gauges. Calibration must be performed to determine the functional relationship between the load
APA, Harvard, Vancouver, ISO, and other styles
5

Niu, Man Ke, Bao Qiang Yang, and Zheng Wei Lei. "The Analysis for Series Mode Noise Suppression in Measuring Equipment Calibration." Advanced Materials Research 718-720 (July 2013): 971–75. http://dx.doi.org/10.4028/www.scientific.net/amr.718-720.971.

Full text
Abstract:
The application of a variety of high-tech equipment, greatly improve the execute effectiveness of the equipment. It plays a decisive role that internal parameters of the device is accurate or not, for the normal function used of these complex instrument systems. The importance of maintenance and calibration process for the test equipments accuracy must be reliable and accurate is increasingly obvious. The series mode noise suppression in equipment measurement and testing process is often encountered and must be solved in related field.
APA, Harvard, Vancouver, ISO, and other styles
6

Niu, Man Ke, Bao Qiang Yang, and Zheng Wei Lei. "The Study for Common Mode Noise Suppression in Measuring Equipment Calibration." Advanced Materials Research 718-720 (July 2013): 967–70. http://dx.doi.org/10.4028/www.scientific.net/amr.718-720.967.

Full text
Abstract:
The application of a variety of high-tech equipment, greatly improve the execute effectiveness of the equipment system. It plays a decisive role that internal parameters of the device is accurate or not, for the normal function used of these complex instrument systems. The importance of maintenance and calibration process for the test equipments accuracy must be reliable and accurate is increasingly obvious. The common mode noise suppression in equipment measurement and testing process is often encountered and must be solved in related field.
APA, Harvard, Vancouver, ISO, and other styles
7

Sulyma, Oleg, Mykola Mykyichuk, and Iryna Zinchuk. "THE MEASURING CHANNELS CALIBRATION IN THE INDUSTRY." Measuring Equipment and Metrology 82, no. 4 (2021): 32–35. http://dx.doi.org/10.23939/istcmtm2021.04.032.

Full text
Abstract:
The trend of development of measuring equipment in particular measuring systems and technological processes leads to the need of measuring the temperature without dismantling the primary transducers and stopping the technological process in a very wide range and with high accuracy. The choice of methods and means of measurement depends on such factors as the value of measured temperature, necessary accuracy of measurement, conditions of measurements, and operation of the investigated object. The topicality of the problem is that industrial metrology operates the temperature measuring systems,
APA, Harvard, Vancouver, ISO, and other styles
8

Amalia, Fika, and Asep Ririh Riswaya. "Web-Based Measuring Instrument Calibration Scheduling Information System." Electronic, Business, Management and Technology Journal 1, no. 2 (2024): 87–93. http://dx.doi.org/10.55208/ebmtj.v1i2.111.

Full text
Abstract:
The production method has prioritized guaranteeing excellent manufacturing quality in response to the increasing competitiveness in the clothing industry. Utilizing a fabric roll meter measuring instrument dramatically enhances the overall quality of the product by guaranteeing precise measurements. Roll meter fabric measuring equipment in the garment industry evaluates product accuracy based on customer specifications, ensuring exceptional quality. Effective regulation is essential for the management and upkeep of cloth roll meter measuring instruments. Therefore, it is necessary to develop a
APA, Harvard, Vancouver, ISO, and other styles
9

Amalia, Fika, and Asep Ririh Riswaya. "Web-Based Measuring Instrument Calibration Scheduling Information System: Case Study of One of the Textile Companies in Bandung City." Electronic, Business, Management and Technology Journal 1, no. 2 (2023): 87–93. https://doi.org/10.55208/yebmtj.v1i2.111.

Full text
Abstract:
The production method has prioritized guaranteeing excellent manufacturing quality in response to the increasing competitiveness in the clothing industry. Utilizing a fabric roll meter measuring instrument dramatically enhances the overall quality of the product by guaranteeing precise measurements. Roll meter fabric measuring equipment in the garment industry evaluates product accuracy based on customer specifications, ensuring exceptional quality. Effective regulation is essential for the management and upkeep of cloth roll meter measuring instruments. Therefore, it is necessary to develop a
APA, Harvard, Vancouver, ISO, and other styles
10

Mosharenkov, Viktor, and Serhii Voitenko. "Development of a generalized mathematical model of static error electromechanical measuring equipment." Advanced Information Systems 5, no. 2 (2021): 38–41. http://dx.doi.org/10.20998/2522-9052.2021.2.06.

Full text
Abstract:
To keep military equipment fit for use, carry out maintenance activities, an important and integral part of which is metrological service. The effectiveness of metrological services depends on the completeness of the coverage of the monitored parameters, frequency and reliability of their measuring control. The most common, at present, when controlling the parameters of military equipment are electromechanical measuring equipment. The main metrological characteristic of electromechanical measuring instruments in a static measurement mode is the nominal calibration characteristic. During operat
APA, Harvard, Vancouver, ISO, and other styles
11

Zakharov, Igor, Olesia Botsiura, Oleksandr Zakharov, Iryna Zadorozhna, Valerii Semenikhin, and Oleg Novoselov. "Main stages of calibration of measuring instruments." Ukrainian Metrological Journal, no. 3 (October 18, 2023): 9–15. http://dx.doi.org/10.24027/2306-7039.3.2023.291862.

Full text
Abstract:
The main stages of calibration of measuring instruments are described. The stage of preparation for calibration and its main steps are considered: setting a measurement task, choosing a method and equipment, choosing (developing) calibration methods and their verification (validation). The content of the measurement experiment is presented together with the main measurement methods that can be used to calibrate the indications of measuring instruments and material measures. The main steps of experimental data processing, which lead to the estimation of the numerical value and uncertainty evalu
APA, Harvard, Vancouver, ISO, and other styles
12

Kawalec, Małgorzata, Czerwińska Karolina, and Andrzej Pacana. "Influence of Technical Condition of Control and Measurement Equipment on Calibration Results." System Safety: Human - Technical Facility - Environment 3, no. 1 (2021): 79–88. http://dx.doi.org/10.2478/czoto-2021-0009.

Full text
Abstract:
Abstract In the paper there are analyzed the procedures used in the process of calibrating concerning control and measurement equipment. There was assumed the mathematical model of the measuring instrument which was then analyzed. The factors that result from the imperfect technical condition of the control and measurement equipment and may have an impact on the measurement results were also analyzed. Models of errors’ models were assumed that may affect the calibration results. The static calibration of control and measurement equipment was analyzed. The results of numerical simulations conce
APA, Harvard, Vancouver, ISO, and other styles
13

Sato, Osamu, Kazuya Matsuzaki, Hiroyuki Fujimoto, Sonko Osawa, Makoto Abe, and Toshiyuki Takatsuji. "Challenge for the Traceable Dimensional Measurement Using CMM in Factory Floor." Applied Mechanics and Materials 870 (September 2017): 243–48. http://dx.doi.org/10.4028/www.scientific.net/amm.870.243.

Full text
Abstract:
Dimensional measurement is a key process in the quality assurance of manufacturing. Not only classical one-dimensional measurement devices, several kind of three-dimensional coordinate measuring systems (CMSs) including coordinate measuring machines (CMMs) are used for dimensional measurement tasks in measurement rooms or in factory floors. For the purpose of the quality guarantee, the measurement for the validation on the products should be performed with the traceable manner. In the case of the dimensional measurement, the measurement results of the products should be stated as the correspon
APA, Harvard, Vancouver, ISO, and other styles
14

Gagliardi, John. "The Calibration Process: Inspection, Measuring, and Test Equipment Control." Biomedical Instrumentation & Technology 43, no. 3 (2009): 225–27. http://dx.doi.org/10.2345/0899-8205-43.3.225.

Full text
APA, Harvard, Vancouver, ISO, and other styles
15

Dziabenko, O. M. "Metrological Activity At the Enterprise." Metrology and instruments, no. 2 (May 21, 2020): 40–43. http://dx.doi.org/10.33955/2307-2180(2)2020.40-43.

Full text
Abstract:
When organizing metrological activity at an enterprise, the question arises of the need to organize verification (metrological confirmation) of measuring equipment that is not used in the field of legislatively regulated.
 In the international standards «Quality Management Systems» (ISO 9001, EN 9100, AQAP-2110), to ensure that the requirements of Section 7.1.5 «Resources for Monitoring and Measurement» are met, the requirement is established that all measuring equipment, as part of a measurement management system, must have metrological confirmation in accordance with the requirements of
APA, Harvard, Vancouver, ISO, and other styles
16

Redziuk, Anatolii, Volodymyr Ageiev, Victor Ustymenko, et al. "About between-calibration period." Avtoshliakhovyk Ukrayiny, no. 1 (253) ’ 2018 (March 26, 2018): 2–7. http://dx.doi.org/10.33868/0365-8392-2018-1-253-2-7.

Full text
Abstract:
Analysis of normative-and-legal documents related to calibration of measuring devices and testing equipment was conducted; a methodology with an example of calculating between-calibration period was proposed; some issues of its optimisation were considered. Keywords: calibration, between-calibration period, methodology, calculation, determination.
APA, Harvard, Vancouver, ISO, and other styles
17

Efremova, N. Yu. "Conformity assessment of measuring equipment within the process of calibration on the example of geometrical product specification measuring instruments." Izmeritel`naya Tekhnika 74, no. 2 (2025): 37–46. https://doi.org/10.32446/0368-1025it.2025-2-37-46.

Full text
Abstract:
Conformity assessment of measuring equipment, which can also be called verification, can be provided within the process of calibration in accredited calibration laboratories in accordance with the requirements of ISO/IEC 17025:2017 “General requirements for the competence of testing and calibration laboratories” on customer's request. However, the task execution in practice is often associated with significant difficulties due to the lack of laboratory personal's knowledge in the fi eld of probability theory and theoretical metrology, as well as the absence of clear and unambiguous rules for t
APA, Harvard, Vancouver, ISO, and other styles
18

Sandela, Ilka, Nila Trisna, and Dara Quthni Effida. "Ketentuan Pengaturan Penteraan Alat Metrologi Legal dalam Transaksi Perdagangan di Indonesia." Ius Civile: Refleksi Penegakan Hukum dan Keadilan 6, no. 1 (2022): 133. http://dx.doi.org/10.35308/jic.v6i1.5231.

Full text
Abstract:
Legal metrology tools such as measuring instruments, measurements, scales and equipment used in trade transactions must be calibrated and recalibrated within a certain period of time. The goal is the measurement results using these tools remain correct as they should be. If it is not calibrated or recalibrated, it can cause measurements to be inaccurate, so that it can be detrimental to consumers in trade. This study aims to study further on the regulation of calibration of legal metrology equipment, sanctions, mechanisms or procedures for calibration and recalibration. The research method use
APA, Harvard, Vancouver, ISO, and other styles
19

S. Arief, Dodi, Amri Pahlevi, and Agus S. Permana. "Calibration of Dial Indicator Using Calibration Tester with JIS B 7503 Standard." Journal of Ocean, Mechanical and Aerospace -science and engineering- (JOMAse) 65, no. 2 (2021): 82–87. http://dx.doi.org/10.36842/jomase.v65i2.204.

Full text
Abstract:
The measurement process is the most important part of the production process in the industrial world. Obtaining good measurement results can not be separated from using measuring instruments that are always maintained. Subsequence, the maintenance of calibration procedures must be carried out periodically based on a predetermined time limit. The calibration process is an activity to compare standard quantities between measuring instruments and testers that are in accordance with the measuring instrument and carried out periodically. The implementation of the calibration process often has gener
APA, Harvard, Vancouver, ISO, and other styles
20

Pueo, Marcos, Raquel Acero, Ángel Gracia, and Jorge Santolaria. "Measuring Sensors Calibration in Worm Gear Rolling Testers." Sensors 20, no. 11 (2020): 3148. http://dx.doi.org/10.3390/s20113148.

Full text
Abstract:
The ISO standard regulating gear-rolling measurement does not specify in detail the calibration and verification procedures for this type of equipment. This may be one of the reasons for the lack of reproducibility in these rolling tests. The uncertainty budget method, which is the most appropriate way to know the accuracy of this dynamic measurement, shows that the measuring sensors’ accuracy is only a part of the total measurement process uncertainty. In this work, a new calibration and verification procedure for a worm gear rolling tester is presented, based on machine tool, coordinate meas
APA, Harvard, Vancouver, ISO, and other styles
21

Wang, Zhengpu, Baoshi Cao, Zongwu Xie, Boyu Ma, Kui Sun, and Yang Liu. "Kinematic Calibration of a Space Manipulator Based on Visual Measurement System with Extended Kalman Filter." Machines 11, no. 3 (2023): 409. http://dx.doi.org/10.3390/machines11030409.

Full text
Abstract:
The calibration of kinematic parameters has been widely used to improve the pose (position and orientation) accuracy of the robot arm. Intelligent measuring equipment with high accuracy is usually provided for the industrial manipulator. Unfortunately, large noise exists in the vision measurement system, which is provided for space manipulators. To overcome the adverse effect of measuring noise and improve the optimality of calibrating time, a calibration method based on extended Kalman filter (EKF) for space manipulators is proposed in this paper. Firstly, the identification model based on th
APA, Harvard, Vancouver, ISO, and other styles
22

Wei Jifeng, 魏继锋, 关有光 Guan Youguang, 周山 Zhou Shan, and 张凯 Zhang Kai. "Online Calibration Methods for High Energy Laser Energy Measuring Equipment." Chinese Journal of Lasers 36, no. 9 (2009): 2399–403. http://dx.doi.org/10.3788/cjl20093609.2399.

Full text
APA, Harvard, Vancouver, ISO, and other styles
23

Pototskiy, Ihor. "NEW APPROACH TO DETERMINING THE NEED OF MEASURING EQUIPMENT CALIBRATION." Measuring Equipment and Metrology 79, no. 2 (2018): 60–63. http://dx.doi.org/10.23939/istcmtm2018.02.060.

Full text
APA, Harvard, Vancouver, ISO, and other styles
24

Meshcheriak, Oleh, and Oleh Velychko. "CALIBRATION OF QUARTZ ELECTRONIC STOPWATCHERS COMPARISON METHOD USING A DIGITAL CAMERA." Measuring Equipment and Metrology 83, no. 3 (2022): 23–29. http://dx.doi.org/10.23939/istcmtm2022.03.023.

Full text
Abstract:
Measurement of time intervals with low accuracy on intervals from a few seconds to several hours or days is relevant for some broad applications in various fields of activity. Such measurements are widely used in the technological processes of various enterprises during the preparation and quality control of the preparation of medicines, during the maintenance of technical equipment and mechanisms, chemical technological processes, etc. For such measurements, manual electronic quartz stopwatches are widely used, which, despite their not too high measurement accuracy, must guarantee users the a
APA, Harvard, Vancouver, ISO, and other styles
25

Pereira, José Miguel Costa Dias, Gonçalo Ribeiro, and Octavian Postolache. "A Flexible, Low-Cost and Algorithm-Independent Calibrator for Automated Blood Pressure Measuring Devices." Applied Sciences 15, no. 6 (2025): 3198. https://doi.org/10.3390/app15063198.

Full text
Abstract:
Arterial hypertension is one of the most important public health problems, especially in developed countries. The quality and calibration of blood pressure (BP) equipment used for non-invasive blood pressure (NIBP) measurement are essential to obtain accurate data that support correct medical diagnostics. This paper includes the hardware and software description of a flexible, low-cost and algorithm-independent calibrator prototype that can be used for the static and dynamic calibration of automated blood pressure measuring devices (ABPMDs). In the context of this paper, the meaning of calibra
APA, Harvard, Vancouver, ISO, and other styles
26

Chekalin, V. F., and A. A. Sukhov. "On the problems of calibrating Russian measuring devices on the satellites for remote sensing the Earth." Geodesy and Cartography 948, no. 6 (2019): 39–47. http://dx.doi.org/10.22389/0016-7126-2019-948-6-39-47.

Full text
Abstract:
The article deals with modern photogrammetric production’s problems appearing at processing the Russian Earth remote sensing data. It is found out that todaythe main of them consists in the absence till now of the working system fortransferring linear and angular measures from national standard to the workingmeasuring devices. The necessity of creating a three-staged calibration scheme, which would guarantee the highest accuracy and stability of operating on-board measuring equipment, is justified. In addition, it is noted, that the existing technology of Earth remote sensing data processing d
APA, Harvard, Vancouver, ISO, and other styles
27

Todorović Drakul, Miljana, Sanja Grekulović, Dušan Petković, and Oleg Odalović. "TESTING METHODS WITH DIFFERENT DEGREES OF SAMPLING IN DETERMINING SYSTEMATIC INFLUENCES AND MEASUREMENT UNCERTAINTIES OF LINEAR MEASURING DEVICES." Contemporary Theory and Practice in Construction 16, no. 1 (2024): 585–97. http://dx.doi.org/10.61892/stp202401012t.

Full text
Abstract:
<p class="ABSTRACT">This work tested several procedures to determine the linear measuring device's systematic influences and measurement uncertainty. Three methods were developed that differ in the degree and density of sampling during measurement and were compared with the existing method used for calibrating linear measuring devices in the Metrology Laboratory accredited for calibrating angle and length, Institute of Geodesy and Geoinformatics, Faculty of Civil Engineering, in Belgrade. The goal is to determine the possibility of introducing these met
APA, Harvard, Vancouver, ISO, and other styles
28

Uyutnova, E. G., D. S. Pecheritsa, S. Yu Burtsev, and A. S. Zavgorodnii. "Group delay of a signal in the receiving path estimation of measuring devices with the use of the step response." Izmeritel`naya Tekhnika, no. 5 (June 10, 2024): 48–53. http://dx.doi.org/10.32446/0368-1025it.2024-5-48-53.

Full text
Abstract:
The current parameters coordinate-time measuring instruments calibration methods of global navigation satellite systems are considered. For coordinate-time measuring instruments calibration in the process of their development and testing, the global navigation satellite systems signals simulators are used. However, the simulators also need a calibration procedure. Currently, there are various methods for ensuring the metrological characteristics of simulators, including their calibration using oscilloscope. However, this method has not only advantages, but also limitations related to the use o
APA, Harvard, Vancouver, ISO, and other styles
29

Gučević, Jelena, Siniša Delčev, Olivera Vasović Šimšić, Miroslav Kuburić, and Bogdan Šakić. "Interlaboratory comparison as a source of information about the problem." Geodetski vestnik 68, no. 01 (2024): 54–68. http://dx.doi.org/10.15292/geodetski-vestnik.2024.01.54-68.

Full text
Abstract:
Methods of evaluation of interlaboratory comparison results are prescribed by ISO standards. Ruler is probably one of the most widely used length measuring instrument in the world. For laboratories that plan to be accredited for the calibration of Ruler, the acquisition of a specialized Measuring bench is not economically feasible. Confidence in the measured result depends on the measurement uncertainty, and where deficiencies are observed, the values that contribute to the measurement uncertainty should be investigated. This paper describes an interlaboratory comparison for a small number of
APA, Harvard, Vancouver, ISO, and other styles
30

Rofi'i, Mohammad, Syafudin Syaifudin, Dyah Titisari, and Bedjo Utomo. "Waterbath Calibrator with Nine Channels Sensor." Indonesian Journal of electronics, electromedical engineering, and medical informatics 1, no. 1 (2019): 1–6. http://dx.doi.org/10.35882/ijeeemi.v1i1.1.

Full text
Abstract:
Water bath is a laboratory equipment that contains water or special liquid that can maintain the temperature under certain conditions during the specified time interval. For this reason, calibration is needed so that the temperature in the chamber waterbath is stable or not. calibration is carried out by comparing measuring instruments and measuring materials to be calibrated to traceable standards that are traceable to national and / or international standards.
 Based on the results of the identification of the problems mentioned above, the author makes a waterbath calibrator entitled "W
APA, Harvard, Vancouver, ISO, and other styles
31

Surdu, M. "Some Features of the Calibration Equipment for Measuring the Parameters of Impedance." Metrology and instruments, no. 6 (December 28, 2018): 21–27. http://dx.doi.org/10.33955/2307-2180(6)2018.21-27.

Full text
Abstract:
Peculiarities of the accurate impedance meters calibration are considered. Author show that most important and complicate part of calibration procedure consists in determination of two uncertainty components: additive error and error, caused by nonlinearity of the meter transfer function.
 Problems of the determination of the additive error are caused by the fact, that there no exist accurate standard of the zero impedance. Author considers the creation of proper zero impedance standard, whose impedance can be arbitrarily close to zero and its impedance remnant can be estimated on the bas
APA, Harvard, Vancouver, ISO, and other styles
32

Novoselov, Oleg. "REGARDING THE ISSUE OF STANDARDIZATION CALIBRATION METHOD OF WORKING STANDARDS." Metrology and instruments, no. 1 (November 29, 2024): 02. https://doi.org/10.30837/2663-9564.2024.1.02.

Full text
Abstract:
The article deals with the development of standardized methods of calibration of working standards, which are used during the verification of measuring equipment in operation and used in the field of legally regulated metrology. The analysis of current calibration methods, which are specified in the "Scope of accreditation" of accredited calibration laboratories, was carried out.
APA, Harvard, Vancouver, ISO, and other styles
33

Bao, Ke Qin, Gu Xiang Ding, and Yi Bo Song. "Error Analysis and Calibration of Infra-Red Temperature Measurement." Applied Mechanics and Materials 333-335 (July 2013): 290–95. http://dx.doi.org/10.4028/www.scientific.net/amm.333-335.290.

Full text
Abstract:
R temperature measurement in electrical equipment is more and more used in temperature measurement, but accuracy of temperature measurement is susceptible to outside interference. The main factors affecting the accuracy of measuring temperature, such as environmental factors, equipment emissivity and distance coefficient, are analyzed, the solution has been put forward. In the environmental conditions under the condition of relatively unchanged ,change rule of the temperature value along with the temperature measuring distance changing from 0.7 to 5 meters is found, and temperature value is ca
APA, Harvard, Vancouver, ISO, and other styles
34

Malkina, I. V. "CONTROL OF DEFECTS IN THE MANUFACTURING OF ENGINEERING PRODUCTS." Izvestiya of Samara Scientific Center of the Russian Academy of Sciences 25, no. 4(2) (2023): 262–69. http://dx.doi.org/10.37313/1990-5378-2023-25-4(2)-262-269.

Full text
Abstract:
The aim of the work is to develop an automated system of control of geometric characteristics of the part type "cylinder head" with the use of nondestructive testing methods. To achieve this goal, the paper describes the methods of diagnostics of defects of mechanical engineering products, presents the structural scheme of the modernized control and measuring system, substantiates the choice of measuring equipment, develops the methodology of measurements, performs an accuracy analysis of the measuring system, describes the procedures for verification and calibration of measuring equipment.
APA, Harvard, Vancouver, ISO, and other styles
35

Novoselov, Oleg. "Evaluation of the measurement uncertainty during the calibration of metal reference gauges of the 2nd category." Ukrainian Metrological Journal, no. 3 (September 26, 2024): 22–29. http://dx.doi.org/10.24027/2306-7039.3.2024.312331.

Full text
Abstract:
The paper considers problematic issues related to ensuring the uniformity of measurements in the field of legal metrology, namely, during the calibration of working measurement standards used for verification of legally regulated measuring instruments. One of the conditions for ensuring the uniformity of measurements is the compliance of any measuring instrument with the requirements that are prescribed in its technical specification, where standardized metrological characteristics are indicated, which allows us to conclude about the suitability of the instrument for measurements in a known ra
APA, Harvard, Vancouver, ISO, and other styles
36

Cioara, Cristian, Marius Morar, Andrada Babut, and Ligia Tuhut. "Assessment of the level of implementation of metrological traceability requirements specific to measurement equipment in the laboratory for explosive materials and pyrotechnic articles." MATEC Web of Conferences 342 (2021): 02007. http://dx.doi.org/10.1051/matecconf/202134202007.

Full text
Abstract:
The scientific article presents a synthesis on the analysis of the implementation of metrological traceability requirements specific to measuring equipment used for performing accredited tests in the field of explosives for civil use and pyrotechnic articles. In order to mitigate / minimize the risk related to the measurement uncertainty it is applied the proper traceability path in compliance with the requirements of the RENAR Policy, so that to ensure the availability of objective evidence for supporting metrological traceability, based on the documents of the implemented system. Also, the p
APA, Harvard, Vancouver, ISO, and other styles
37

Sevda Aghammadova, Kazim Maharramli, Sevda Aghammadova, Kazim Maharramli. "APPLİCATİON OF THERMİSTORS AND THEİR CALİBRATİON." PAHTEI-Procedings of Azerbaijan High Technical Educational Institutions 41, no. 06 (2024): 219–25. http://dx.doi.org/10.36962/pahtei41062024-23.

Full text
Abstract:
The basis of thermodynamic methods is that temperature accuracy should be high. When choosing thermal transducers, you should be guided by the following requirements for measuring equipment, the performance of which allows you to successfully use thermodynamic methods for diagnosing hydraulic machines in real working conditions: • high output signal level; • minimal inertia of heat exchangers; • high stability during operation; • minimum dimensions of primary heat exchangers; • sensitivity to vibration and shock; • sensitivity to external electromagnetic fields; • ability to use serial measuri
APA, Harvard, Vancouver, ISO, and other styles
38

Nelson, T. R., and D. H. Pretorius. "Device for the calibration of flow-velocity-measuring Doppler ultrasound equipment." Journal of Ultrasound in Medicine 9, no. 10 (1990): 575–81. http://dx.doi.org/10.7863/jum.1990.9.10.575.

Full text
APA, Harvard, Vancouver, ISO, and other styles
39

Erard, L. "Traceability of measuring equipment and standards in testing and calibration laboratories." Accreditation and Quality Assurance 1, no. 3 (1996): a130–134. http://dx.doi.org/10.1007/pl00010400.

Full text
APA, Harvard, Vancouver, ISO, and other styles
40

Zhukov, B., and A. Мakarynska. "THE USE OF MATHEMATICAL MODELLING TO ESTABLISH THE INTERCALIBRATION INTERVAL OF MEASURING LABORATORY INSTRUMENTS OF GRAIN LABORATORIES." Scientific Works 88, no. 2 (2024): 108–14. https://doi.org/10.15673/swonaft.v88i2.3044.

Full text
Abstract:
Calibration of measuring instruments is a critical aspect of ensuring the accuracy, reliability, and standardization of quality and safety assessments in grain laboratories. Precise measurements are essential for evaluating key agricultural product parameters, including moisture content, protein concentration, and contaminant levels, which directly influence market value, food safety, and regulatory compliance. Regular calibration of laboratory equipment is mandated by ISO/IEC 17025:2017, which establishes general requirements for the competence of testing and calibration laboratories. This st
APA, Harvard, Vancouver, ISO, and other styles
41

Sun, Hua Jie, Jin Huang, Ge Guo, and Ying Hu. "A Multi-Degree of Freedom Laser Scanning Simulation Platform." Applied Mechanics and Materials 423-426 (September 2013): 2435–38. http://dx.doi.org/10.4028/www.scientific.net/amm.423-426.2435.

Full text
Abstract:
The multi-degree of freedom laser scanning simulation platform used for simulating most on-line scanning and measuring equipments in manufacturing fields is beneficial to raise the design efficiency and save the design time of dedicated measurement equipment. The measuring model of the system is established by combining the D-H kinematics model with the linear structured light model in the article. The system model parameters are calibrated via various calibration methods. The results obtained have been analyzed by scanning criterion sphere in different angle and position. The experiments show
APA, Harvard, Vancouver, ISO, and other styles
42

Hamel, P., and V. Schmidt. "The calibration laboratories for the measurement of radon and short-lived radon decay products at the Federal Office for Radiation Protection (BfS)." Kerntechnik 66, no. 4 (2001): 202–5. http://dx.doi.org/10.1515/kern-2001-0084.

Full text
Abstract:
Abstract In order to guarantee a high level of accuracy in all areas concerned with radon and radon decay products measurement the BfS has established a quality assurance management system. A set of calibration chambers and containers was installed in the laboratories which were subsequently accredited as a German Calibration Service (DKD) Calibration Laboratory for the units of radon and the potential alpha energy concentration of its short-lived decay products. It is traced back to the national standard established at the Physikalisch-Technische Bundesanstalt (PTB), which is at the same time
APA, Harvard, Vancouver, ISO, and other styles
43

Shabashkevich, B., Yu Dobrovolsky, and V. Yuriev. "Metrological Complex for Verification and Calibration Optoelectronic Devices, Sensitive in the Infrared." Metrology and instruments, no. 1 (March 25, 2019): 25–30. http://dx.doi.org/10.33955/2307-2180(1)2019.25-30.

Full text
Abstract:
The complex of metrological equipment for metrological researches of measuring equipment is presented. Purpose — measurement of energy illumination in the spectral range of (0,6—25) μm. The complex has an extended range of measurement of energy illumination and minimal errors of their measurement.
APA, Harvard, Vancouver, ISO, and other styles
44

Tarash, Heorhii, and Mykola Cherniak. "Calibration of the three-axis accelerometer navigation unit in operation on low precision equipment." MECHANICS OF GYROSCOPIC SYSTEMS, no. 45 (May 15, 2023): 17–26. http://dx.doi.org/10.20535/0203-3771452023285691.

Full text
Abstract:
A method for calibrating a three-axis accelerometer unit of the navigation accuracy class is proposed. It is based on measuring the modulus of the gravity acceleration vector. The method provides the determination of twelve passport coefficients (including six separate values of non-orthogonality angles) of the linear metrological model of a stationary accelerometer unit under operating conditions. The developed method makes it possible to calculate the acceleration value with an acceptable error using non-precision equipment for calibration. The problem is solved by forming a system of linear
APA, Harvard, Vancouver, ISO, and other styles
45

Averchenkova, E. E., and A. A. Shabanov. "Model and Methodology for Optimal Equipment Setting for Monitoring and Verification of Enterprises of the Automotive Cluster." Proceedings of the Southwest State University 26, no. 1 (2022): 73–91. http://dx.doi.org/10.21869/2223-1560-2022-26-1-73-91.

Full text
Abstract:
Purpose of research. To develop a classifier of control and verification equipment, to propose a model of a set of control and verification equipment, as well as a methodology for forming an optimal set of control and verification equipment to ensure the effective functioning of an organizational and technological system for providing mechanical assembly based on threaded connections of an automated assembly process control system at automotive cluster enterprises.Methods. Calibration equipment set in the assembly production organizational and technological system based on thread joints of the
APA, Harvard, Vancouver, ISO, and other styles
46

BANGI, J. O., S. M. MARANGA, S. P. NGANGA, and S. M. MUTULI. "FORCE MEASUREMENT SERVICES AT KEBS: AN OVERVIEW OF EQUIPMENT, PROCEDURES AND UNCERTAINTY." International Journal of Modern Physics: Conference Series 24 (January 2013): 1360010. http://dx.doi.org/10.1142/s2010194513600100.

Full text
Abstract:
This paper describes the facilities, instrumentation and procedures currently used in the force laboratory at the Kenya Bureau of Standards (KEBS) for force measurement services. The laboratory uses the Force Calibration Machine (FCM) to calibrate force-measuring instruments. The FCM derives its traceability via comparisons using reference transfer force transducers calibrated by the Force Standard Machines (FSM) of a National Metrology Institute (NMI). The force laboratory is accredited to ISO/IEC 17025 by the Germany Accreditation Body (DAkkS). The accredited measurement scope of the laborat
APA, Harvard, Vancouver, ISO, and other styles
47

Vikas, C. Mali*1 Asmita G. Lonare 2. Namrta V. Thigale3. "Precision Measurement Techniques: Calibration Procedures for Scientific Instruments." International Journal in Pharmaceutical Sciences 2, no. 4 (2024): 674–79. https://doi.org/10.5281/zenodo.10980432.

Full text
Abstract:
This document outlines the calibration procedures for various laboratory equipment essential for accurate and reliable measurements in scientific studies. Specifically, it details the calibration of volumetric flasks, measuring cylinders, graduated pipettes, and pH meters. The procedures involve meticulous steps to ensure adherence to tolerance limits and maintain the quality of data generated in laboratory settings.
APA, Harvard, Vancouver, ISO, and other styles
48

Latuconsina, Abdul Kadir, Fahrudin Ramly, and Dientje Rumerung. "The Effectiveness of Weighing Scale Calibration/Recalibration in Consumer." PUBLIC POLICY (Jurnal Aplikasi Kebijakan Publik & Bisnis) 5, no. 2 (2024): 855–71. https://doi.org/10.51135/publicpolicy.v5.i2.p855-871.

Full text
Abstract:
The activity of calibration/re-calibration has influenced consumer behavior in purchasing goods. The purpose of this study is to understand consumer behavior in determining purchases from sellers whose measuring, weighing, and related equipment (UTTP) have been calibrated/re-calibrated, and its implications on seller income. This research uses a qualitative method. The data used is primary data obtained by conducting interviews with 50 consumers and 50 sellers using incidental sampling techniques. Data and information obtained were analyzed qualitatively through descriptive analysis and narrat
APA, Harvard, Vancouver, ISO, and other styles
49

Ilnytska, T., and Kh Vasylykha. "The Means of Measuring Equipment Related to the Measurement of Mass in and Outside the Area of Legally Regulated Metrology." Metrology and instruments, no. 4 (September 7, 2019): 55–61. http://dx.doi.org/10.33955/2307-2180(4)2019.55-61.

Full text
Abstract:
In the article the peculiarities of applying the requirements of the new edition of the Law of Ukraine «On metrology and metrological activity» to the means of measuring equipment, which are put into exploitation and used in and outside the area of legally regulated metrology are considered. The means of measuring equipment which are put into circulation, placed on the market or put into exploitation and used in the area of legally regulated metrology shall comply with the requirements of all applicable Technical Regulations (Directives for EU) applicable to them. On the example of the measuri
APA, Harvard, Vancouver, ISO, and other styles
50

Satria Ningrum, Erlina Dwi Santhika Satria Ningrum, Dian Anggraini Purwaningtyas, and Toni. "ANALISIS PENURUNAN JANGKAUAN PANCARAN T-DME (TERMINAL-DISTANCE MEASURING EQUIPMENT) MERK NEC NNG-1796A DI BANDARA INTERNASIONAL MINANGKABAU." Teknika STTKD: Jurnal Teknik, Elektronik, Engine 10, no. 1 (2024): 90–97. http://dx.doi.org/10.56521/teknika.v10i1.1103.

Full text
Abstract:
Terminal Distance Measuring Equipment (T-DME) is a type of aviation navigation equipment that helps pilots provide distance information to landing location points. This T-DME is usually installed side by side with the Landing System Instrument equipment, namely Glide-Path, in this case the T-DME has the function of providing distance information, especially to the Glide Path ground station when carrying out aircraft landing procedures. To ensure that the T-DME equipment is in normal operating condition, calibration activities need to be carried out so that the T-DME equipment remains in accord
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!