Academic literature on the topic 'Capacité ionique'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Capacité ionique.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "Capacité ionique"

1

Sarre, M. J., and M. Mazet. "Elimination de l'ion chrome hexavalent dans l'eau par les celluloses greffées." Revue des sciences de l'eau 1, no. 1-2 (2005): 55–71. http://dx.doi.org/10.7202/705003ar.

Full text
Abstract:
L'étude concerne le chrome (VI) et son élimination dans l'eau par les celluloses greffées (échangeuse d'anions) AE2 sous forme OH¯, Cl¯, S04=. La capacité d'échange correspond à 0,5-0,6 meq g-1 de cellulose. Les cinétiques d'échanges du Cr (VI) avec les ions CL¯ OH¯ et SO4 ont été déterminées en fonction du pH du milieu, de la température, de ta force ionique, de La quantité de détergents et des formes de celluloses AE2. Les résultats expérimentaux montrent que les formes de celluloses sont efficaces dans l'ordre OH¯ > Cl¯ > SO4= vis-à-vis du Cr (VI) et que l'échange décroît pour les ion
APA, Harvard, Vancouver, ISO, and other styles
2

Gaspard, P. G., J. Wiartz, and J. Schwartzbrod. "Étude expérimentale de l'adhésion des oeufs d'helminthes (Ascaris suum): conséquences pour l'environnement." Revue des sciences de l'eau 7, no. 4 (2005): 367–76. http://dx.doi.org/10.7202/705206ar.

Full text
Abstract:
Les oeufs de nématodes sont présents dans les eaux usées et dans les boues résiduaires. Suite à ce constat, l'objectif de ce travail est la mise en évidence d'une éventuelle capacité d'adhésion par contact et fixation des oeufs sur différentes surfaces. L'oeuf d'Ascaris a été utilisé comme modèle et divers paramètres sus- ceptibles d'intervenir ou de modifier les interactions ont été testés. Sur les matériaux de laboratoire, 32,5 % des oeufs se fixent sur les tubes de verre contre respectivement 15,7 % et 9,1 % sur des tubes en polystyrène et en polypropylène. En eau désionisée, les oeufs mont
APA, Harvard, Vancouver, ISO, and other styles
3

Mouhanni, Hind, Hassan Hamdi, Abdelaziz Bendou, Lhoussine Benzine, and Eric Cavalli. "Impact de la réutilisation des eaux usées épurées en irrigation : analyse ionique des lixiviats." Revue des sciences de l’eau 25, no. 1 (2012): 69–73. http://dx.doi.org/10.7202/1008536ar.

Full text
Abstract:
Au Maroc, pays du pourtour méditerranéen, les ressources en eau sont limitées et inégalement réparties dans l’espace et dans le temps. Agadir, ville du sud du Maroc, fait partie de la région du Souss connue pour ses activités d’agriculture et de pêche. La région est connue par un climat semi-aride et un grand déficit hydrique. Afin de préserver la qualité des masses d’eau et pour diminuer les prélèvements dans le milieu naturel, il convient de chercher des approvisionnements alternatifs. La réutilisation des eaux usées épurées semble être une bonne alternative, notamment en irrigation. Le pote
APA, Harvard, Vancouver, ISO, and other styles
4

Ayele, J., A. Mahi, and M. Mazet. "Étude de l'adsorption de l'atrazine sur le charbon actif en poudre en présence de tensioactifs." Revue des sciences de l'eau 8, no. 3 (2005): 355–70. http://dx.doi.org/10.7202/705228ar.

Full text
Abstract:
Les tensioactifs, adjuvants participant à la formulation des pesticides peuvent se trouver en compétition avec ces derniers lors de l'adsorption sur charbon actif en poudre (CAP) utilisé au cours du traitement de potabilisation des eaux. L'adsorption de l'atrazine, qui reste l'un des produits phytosanitaires le plus souvent détecté dans les eaux de surface malgré les réglementations sur son utilisation, a été étudiée en présence de trois tensioactifs afin de déterminer l'influence de ces derniers; il a été choisi un tensioactif anionique (DSS), cationique (BHTA), et un non ionique (DE6). Les r
APA, Harvard, Vancouver, ISO, and other styles
5

Castetbon, A., M. Corralès, M. Potin-Gauthier, and M. Astruc. "Etude cinétique de la complexation du cuivre en milieu hydrogénocarbonate par électrochimie." Revue des sciences de l'eau 4, no. 2 (2005): 239–52. http://dx.doi.org/10.7202/705098ar.

Full text
Abstract:
La détermination de la capacité complexante des eaux naturelles est généralement effectuée par titrage ampérométrique du cuivre à pH fixé. Beaucoup, sinon tous les tampons classiques utilisés perturbent les études de spéciation du cuivre par formation de complexes peu stables. Dans ce travail nous nous sommes intéressés à la complexation du cuivre par les ions carbonates généralement présents dans les eaux naturelles. Afin de mener à bien notre étude, nous avons mesuré, dans un milieu synthétique de force ionique et pH contrôlés (KNO3 0,02 M + NaHCO3 2,38.10-3 M) toutes les constantes des dive
APA, Harvard, Vancouver, ISO, and other styles
6

Tursunmuratov, Obid, Suyun Khushvaktov, Murod Jurayev, Davronbek Bekchanov, and Mukhtarjan Mukhamediev. "Adsorption and Kinetic Studies of Nickel(II) Ions onto Vermiculite based Ionite." Asian Journal of Chemistry 36, no. 1 (2023): 120–24. http://dx.doi.org/10.14233/ajchem.2024.30682.

Full text
Abstract:
Using vermiculite based ionite, the absorption efficiencies of Ni2+ ions from synthetic solutions were investigated. The effects of pH and initial concentration of Ni2+ ions their absorption capacity were investigated to optimize process conditions using pseudo-first and pseudo-second-order. The results obtained from the sorption of Ni2+ ions on vermiculite based ionite show the kinetic characteristics close to the pseudo-second order. The high Ni2+ ions sorption is attributed due to the the complexation of metal ions with −NH2 groups present in the absorbent, which results in the strong coord
APA, Harvard, Vancouver, ISO, and other styles
7

Abdraliyeva, Gulzhan E., N. A. Bektenov, N. A. Samoilov, and A. K. Baidullaeva. "Sorption of Metal Ions by New Sulfur-Containing Ionite GMA-MMA-TDGA." Applied Mechanics and Materials 863 (February 2017): 48–52. http://dx.doi.org/10.4028/www.scientific.net/amm.863.48.

Full text
Abstract:
А new polyethyleneimine sulfur-containig exchanger network structure with static exchange capacity of 0.1 N solution of HCl 4.7 mEq/g was obtained by polycondensation of glycidyl methacrylate, methyl methacrylate and phosphoric acid. Sorption of copper (II) and zinc (II) ions was studied and investigated in static conditions from model solutions of sulfates of copper and zinc, in dependence on their concentration and pH, as well as their contact time with the ion-exchanger. Found that the magnitude of the sorption capacity of the ion exchanger for ions of copper (II) at pH 3.6 CuSO4 solution i
APA, Harvard, Vancouver, ISO, and other styles
8

Sylvain-Bonfanti, Lucia, Julien Page, Delphine Arbelet-Bonnin, et al. "L’anesthésie, un processus commun à tout le vivant." médecine/sciences 39, no. 10 (2023): 738–43. http://dx.doi.org/10.1051/medsci/2023123.

Full text
Abstract:
Du fait de leur intérêt en médecine, la majeure partie des études actuelles sur les anesthésiques se concentrent sur le système nerveux des animaux et négligent le fait que toute forme de vie peut être anesthésiée. En effet, l’anesthésie cible des canaux dépendants du voltage, canaux qui existent dans un grand nombre d’espèces diverses et qui proviennent de canaux ancestraux antérieurs à l’apparition même des eucaryotes. La question demeure : le maintien au cours de l’évolution de la capacité à être anesthésié est-il dû à un avantage adaptatif ou à un simple défaut intrinsèque des canaux ioniq
APA, Harvard, Vancouver, ISO, and other styles
9

Toirova, G.Kh, and H.Kh. Turaev. "STUDY OF DETERMINATION OF STATIC EXCHANGE CAPACITY OF COMPLEX DERIVATIVE IONITES BY TITRIMETRIC METHOD." Multidisciplinary Journal of Science and Technology 3, no. 3 (2023): 78–83. https://doi.org/10.5281/zenodo.8430388.

Full text
Abstract:
This article presents the determination of the static exchange capacity of complex forming ions using the method of titrimetric analysis. Based on the data obtained as a result of the study of the dependence of the sorption of some metal ions on various factors in the tested anionites, the optimal indicators of the sorption process were selected. It was also shown that in the process of sorption of copper ions, in addition to the industrial anionite AN-31, the anionite DMT+GIPAN obtained on the basis of local raw materials can be used.
APA, Harvard, Vancouver, ISO, and other styles
10

Kovrigina, T. V., K. Kh Khakimbolatova, T. K. Chalov, and B. Y. Begenova. "PROMISING MULTIFUNCTIONAL ANIONITES FOR THE EXTRACTION OF CHROMIUM (VI) IONS." Chemical Journal of Kazakhstan, no. 2 (June 15, 2023): 118–29. http://dx.doi.org/10.51580/2023-2.2710-1185.19.

Full text
Abstract:
30% of the chromium ore reserves in the world are concentrated in Kazakhstan, during the processing of which large volumes of wastewater containing toxic chromium salts, are formed. Сhromium is one of the priority components both in terms of emission and toxicity (for Cr(VI), the maximum permissible concentration is 0.05 mg/l). The compounds of chromium (III) and especially chromium (VI) have a general toxic, allergenic, carcinogenic, mutagenic effect on the human body, and are among the most dangerous pollutants for the environment. The aim of this work is to develop a technological scheme fo
APA, Harvard, Vancouver, ISO, and other styles
More sources

Dissertations / Theses on the topic "Capacité ionique"

1

Moukheiber, Eddy. "Compréhension par établissement de courbes d'étalonnage de la structure des membranes perfluorées sulfoniques pour pile à combustible." Phd thesis, Université de Grenoble, 2011. http://tel.archives-ouvertes.fr/tel-00873025.

Full text
Abstract:
Ce travail de thèse a pour but l'étude des effets de la contamination cationique sur la membrane électrolyte afin d'élaborer des outils de caractérisation et de diagnostic de cette pollution. Premièrement, la caractérisation physico-chimique de membranes PFSA commerciales a révélé des paramètres pertinents de structure et de propriété, qui ont été étudiés en fonction de leur dépendance à la capacité d'échange ionique (IEC).Deuxièmement, les propriétés thermiques des membranes contaminées par des cations ont révélé des changements dépendant fortement de l'acidité de Lewis du cation (LAS). Cette
APA, Harvard, Vancouver, ISO, and other styles
2

Dumas, Carine. "Synthèse par implantation ionique, adressage, caractérisations électriques et optiques d'un nombre réduit de nanocristaux de Si dans SiO2." Toulouse, INSA, 2008. http://eprint.insa-toulouse.fr/archive/00000248/.

Full text
Abstract:
Ce travail est consacré à la synthèse localisée et contrôlée de nanocristaux de Si dans une couche de SiO2 (<10 nm) par deux techniques d’implantation ionique. D’une part, l’implantation ionique à basse énergie (1keV) suivie d’un recuit thermique (ULE-II) permet d’élaborer un plan de nanocristaux dans une couche d’oxyde, d’autre part l’ULE-II couplée à la lithographie stencil (méthode originale SMULE- II) permet de les synthétiser localement et de contrôler leur nombre. Les caractérisations par MEB, AFM, EFTEM, spectroscopie de photoluminescence permettent l’étude structurale des nanocrista
APA, Harvard, Vancouver, ISO, and other styles
3

Valade, David. "Synthèse de Copolymères fluorés porteurs de groupements ammonium pour liants d'électrode de piles à combustible alcalines à coeur solide." Phd thesis, Université Montpellier II - Sciences et Techniques du Languedoc, 2007. http://tel.archives-ouvertes.fr/tel-00181780.

Full text
Abstract:
L'objectif de cette thèse a consisté à synthétiser un liant d'électrode, à base de polymère, afin d'augmenter la surface de contact entre les électrodes et la membrane électrolytique. Pour cela, la synthèse de copolymères fluorés de différentes architectures a été réalisée. Des polymères linéaires ont été synthétisés par modification chimique de polymères commerciaux porteurs d'ammonium quaternaires (poly(chlorure de diallyldiméthyl ammonium) ou PDADMAC), mais aussi par modification chimique de copolymères poly(chlorotrifluoroéthylène-alt-chloroéthylvinyl éther) préalablement synthétisés en au
APA, Harvard, Vancouver, ISO, and other styles
4

Bazin, Laurent. "Anodes nanostructurées pour microbatteries 3D Li-ion." Toulouse 3, 2009. http://thesesups.ups-tlse.fr/815/.

Full text
Abstract:
Cette thèse a pour sujet l'élaboration et la caractérisation d'anodes nano-architecturées pour des applications en microbatteries Li-ion 3D. Ces électrodes sont basées sur un collecteur de courant nano-structuré, constitué d'un tapis de nano-piliers de cuivre (Ø200nm, L=2µm) alignés verticalement. L'objectif de ce travail a été de montrer les avantages d'une électrode tridimensionnelle en revêtant ce substrat avec différents matériaux actifs en utilisant différentes techniques. De l'étain métallique Sn a pu être déposé par voie électrochimique et forme une couche conforme sur la nanostructure
APA, Harvard, Vancouver, ISO, and other styles
5

Perez, Emeric. "Intégration hétérogène de composants passifs silicium pour les convertisseurs de puissance intégrés." Electronic Thesis or Diss., Université Grenoble Alpes, 2025. http://www.theses.fr/2025GRALY001.

Full text
Abstract:
La miniaturisation des systèmes électroniques pose un défi de plus en plus complexe, notamment en ce qui concerne l'alimentation, qui représente une part importante et limitante du circuit. Comme expliqué au chapitre 1, l'intégration des composants passifs reste l'un des principaux obstacles à cette miniaturisation. En effet, les composants passifs intégrés dans la technologie CMOS affichent des densités de capacité deux ou trois ordres de grandeur inférieures à celles des composants discrets. Cette thèse vise à proposer des solutions compactes et intégrables en technologie CMOS en utilisant d
APA, Harvard, Vancouver, ISO, and other styles
6

Coustan, Laura. "Matériaux pseudo-capacitifs pour supercondensateurs flexibles." Thesis, Montpellier, 2015. http://www.theses.fr/2015MONTS169/document.

Full text
Abstract:
Les supercondensateurs sont des dispositifs de stockage de l'énergie électrique particulièrement intéressants pour les applications de puissance. Les rendre flexibles permet de considérer de nouvelles possibilités d'intégration. Néanmoins, l'optimisation de la densité d'énergie, point faible de ces dispositifs, passe par la recherche et l'étude de nouveaux matériaux d'électrode et d'électrolytes. Dans ce but, ce travail de thèse s'est orienté vers des matériaux pseudo-capacitifs, avec l'utilisation d'électrodes à base de MnO2, et d'électrolytes à base de liquide ionique fonctionnalisé de type
APA, Harvard, Vancouver, ISO, and other styles
7

Bentahar, Yassine. "Caractérisation physico-chimique des argiles marocaines : application à l’adsorption de l'arsenic et des colorants cationiques en solution aqueuse." Thesis, Université Côte d'Azur (ComUE), 2016. http://www.theses.fr/2016AZUR4081/document.

Full text
Abstract:
De nos jours les ressources en eau potable sont fortement réduites suite à une augmentation démographique accompagnée d’une forte industrialisation et d’un développement intensif de l’agriculture. Les rejets de micropolluants d’origine variable (pesticides, colorants, phénols, métaux lourds…) dans l’environnement ne cessent d’augmenter. Ces polluants, toxiques et peu dégradables, sont en général à l’origine de nombreux effets nocifs sur la santé. Ils affectent aussi directement l’équilibre des écosystèmes suite à la dégradation de la qualité des différents milieux de l’environnement (sol, eau,
APA, Harvard, Vancouver, ISO, and other styles
8

Vico, Sabine. "Etude de membranes échangeuses anioniques à base de polysulfone: influence de la nature du site ammonium quaternaire sur les propriétés électromembranaires." Doctoral thesis, Universite Libre de Bruxelles, 2005. http://hdl.handle.net/2013/ULB-DIPOT:oai:dipot.ulb.ac.be:2013/210939.

Full text
Abstract:
<p align="justify">Des membranes échangeuses anioniques à base de polysulfone, portant des sites échangeurs de type ammonium quaternaire, ont été préparées. Misant sur la possibilité d’établissement d’interactions spécifiques entre les espèces échangées et les sites chargés, nous avons fait varier la longueur des chaînes alkyles sur l’azote de un à trois carbones, dans le but de moduler le transport d’anions caractérisés par des propriétés d’hydratation différentes.</p><p><p><p align="justify">La réaction d’halométhylation a été choisie pour l’introduction préalable sur le squelette polymériqu
APA, Harvard, Vancouver, ISO, and other styles
9

Aliane, Abdelkader. "Développement de bolomètre refroidi à 0,1 K pour une détection X dans la gamme 100 eV - 10 keV." Phd thesis, Grenoble INPG, 2009. http://www.theses.fr/2009INPG0005.

Full text
Abstract:
Les missions d'astronomie X de nouvelle génération (IXO par exemple) sont à l'étude. Ces missions seront équipées de miroirs X de grande surface effective, à bande passante étendue vers les hautes énergies et à haute résolution angulaire. Ceci implique l'utilisation au plan focal de détecteurs spectro-imageurs de performances en rapport, améliorés en terme de taux de comptage, de bande passante en énergie et de résolution spectrale par rapport aux CCDs qui constituent la base des instruments actuels. Le travail réalisé dans cette thèse consiste en l'extrapolation à la détection X de matrices d
APA, Harvard, Vancouver, ISO, and other styles
10

Aliane, Abdelkader. "Développement de bolomètre refroidi à 0,1 K pour une détection X dans la gamme 100 eV – 10 keV." Phd thesis, Grenoble INPG, 2009. http://tel.archives-ouvertes.fr/tel-00387573.

Full text
Abstract:
Les missions d'astronomie X de nouvelle génération (IXO par exemple) sont à l'étude. Ces missions seront équipées de miroirs X de grande surface effective, à bande passante étendue vers les hautes énergies et à haute résolution angulaire. Ceci implique l'utilisation au plan focal de détecteurs spectro-imageurs de performances en rapport, améliorés en terme de taux de comptage, de bande passante en énergie et de résolution spectrale par rapport aux CCDs qui constituent la base des instruments actuels. Le travail réalisé dans cette thèse consiste en l'extrapolation à la détection X de matrices d
APA, Harvard, Vancouver, ISO, and other styles
More sources
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!