To see the other types of publications on this topic, follow the link: Caudal de água de lavagem.

Dissertations / Theses on the topic 'Caudal de água de lavagem'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 50 dissertations / theses for your research on the topic 'Caudal de água de lavagem.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.

1

Brand, Simone Cristiane. "Isolamento e identificação de substâncias provenientes da laranjeira ´Valência` (Citrus sinensis) envolvidas no estímulo e/ou quebra da dormência de estruturas quiescentes de Colletotrichum acutatum, agente causal da podridão floral dos citros." Universidade de São Paulo, 2012. http://www.teses.usp.br/teses/disponiveis/11/11135/tde-23032012-165119/.

Full text
Abstract:
A podridão floral dos citros (PFC), causada por Colletotrichum acutatum, induz a abscisão de frutos jovens, podendo causar perdas de até 100%. A presença de inóculo viável na forma de conídios e/ou apressórios quiescentes na planta justifica a ocorrência generalizada da doença. Em períodos de chuva a PFC é agravada, possivelmente, em função de substâncias lavadas das diferentes partes da planta, as quais contêm metabólitos que estimulam o desenvolvimento do fungo. Diante do exposto, objetivou-se verificar o efeito das águas de lavagem brutas (ALBs) de flores, botões, folhas velhas (FV) e folhas novas (FN) e mistura destas sobre conídios, apressórios e hifas quiescentes de C. acutatum (isolados 61A e 142) in vitro e in vivo e sobre a severidade da PFC, bem como identificar substâncias presentes nas ALBs, exibindo a atividade biológica de interesse. Além disso, buscou-se verificar variações na composição das ALBs. O efeito de compostos voláteis brutos (CVBs) e os identificados a partir de laranjeira Valência (linalol, limoneno, mirceno, nonanal e a mistura destes) sobre o desenvolvimento do patógeno também foi avaliado. Todas as frações das ALBs estimularam a germinação dos conídios do fungo, sendo que a ALB de flores apresentou o maior estímulo para ambos os isolados. Para apressórios quiescentes (isolado 61A), o maior estímulo foi verificado nos tratamentos com ALBs de botões e da mistura e para conídios no tratamento mistura. Os maiores valores para comprimento do tubo germinativo foram observados nos tratamentos mistura, FN e botões. Para as estruturas quiescentes, o efeito das ALBs foi mais significativo para o isolado 142. Não foi observado efeito das ALBs sobre o micélio quiescente. Houve estímulo da germinação de conídios e ramificação de hifas in vivo, principalmente, em resposta ao tratamento com ALB de botões. A aplicação da ALB da mistura em flores resultou em maior severidade da PFC. Por sua vez, os CVBs apresentaram efeito inibitório. A exposição do isolado 61A aos voláteis (CVs) linalol, nonanal e mistura, resultou em germinação apenas na menor dose. O mirceno manteve a germinação semelhante a testemunha em todas as doses testadas, assim como limoneno nas doses de 0,005 a 0,25 µL mL-1. Todos os voláteis reduziram o comprimento do tubo germinativo. Para o isolado 142, houve redução em todas as variáveis para todas as doses dos CVs. Houve variações na composição das ALBs nas diferentes coletas, o que explica em parte a variação na capacidade de estímulo em alguns testes. Na ALB de flores, identificou-se a presença de cafeína, dos flavonóides glicosilados hesperidina e naringina, além de compostos glicosilados e peptídeos. Nas partes vegetais de laranjeira Valência foram identificados 54 CVs. As ALBs apresentam efeito estimulatório sobre conídios e apressórios quiescentes de C. acutatum in vitro e in vivo, bem como sobre a severidade da PFC. Os CVs linalol, limoneno, mirceno, nonanal e a mistura destes são, de forma geral, inibitórios ao desenvolvimento de C. acutatum.
The postbloom fruit drop of citrus (PFDC), caused by Colletotrichum acutatum, induces abscission of young fruits, and it may cause losses up to 100%. The presence of viable inoculum in the form of conidia and/or quiescent appressoria on the plant justifies the widespread occurrence of the disease. Under rain, the PFDC is increased, possibly due to substances washed from different parts of the plant, which contain metabolites that stimulate the development of the fungus. Therefore, we aimed to determine the effect of watery washing (WWs) of flowers, flower buds, old leaves (OL) and young leaves (YL) and the mixture of them on quiescent conidia and hyphae of C. acutatum (isolates 61A and 142) in vitro and in vivo and on the severity of the PFDC, and to identify substances in the WWs, exhibiting the biological activity of interest. In addition, variations in the composition of WWs were determinated. The effect of crude volatile compounds (CVCs) and those identified from Valencia sweet orange (linalool, limonene, myrcene, nonanal and the mixture of them) on the development of the pathogen was also evaluated. All fractions of WWs stimulated spore germination, and the flower WW exhibited the highest effect for both isolates. For quiescent appressoria (isolate 61A), the highest stimulus was observed in treatments with WWs from flower buds and the mixture and for quiescent conidia in the treatment mixture. The highest values for germ tube length were observed on the treatments mixture, YL and flower buds. For the quiescent structures, the effect of WWs was more significant for isolate 142. There was no effect of WWs on the quiescent mycelium. There was stimulation of conidia germination and hyphal branching in vivo in response mainly to treatment with WW from flower buds. The application of the mixture of WW in flowers resulted in higher severity of the PFDC. On the other hand, the CVCs showed inhibitory effect. Exposure of the isolate 61A to the volatiles (VCs) linalool, nonanal and the mixture of them, resulted in germination only at the lowest concentration. The germination on myrcene was similar to control at all doses tested as well as on limonene at doses from 0.005 to 0.25 mL mL-1. All volatiles reduced the length of the germ tube. In the case of isolate 142, a reduction in all variables for all concentration of VCs was observed. There were changes in the composition of WWs based upon times of harvesting, which partly explains the variations observed in the ability to stimulate the structures in some experiments. In flower WWs, we identified the presence of caffeine, the flavonol glycosides hesperidin and naringin, glycosylated compounds and peptides. In the plant parts of sweet orange \'Valencia\' were identified 54 VCs. The WWs have stimulatory effect on quiescent conidia and appressoria of C. acutatum in vitro and in vivo as well as in the severity of the PFDC. The VCs linalool, limonene, myrcene, nonanal and the mixture of them are, in general, inhibitory to the development of C. acutatum.
APA, Harvard, Vancouver, ISO, and other styles
2

Morelli, Eduardo Bronzatti. "Reuso de água na lavagem de veículos." Universidade de São Paulo, 2005. http://www.teses.usp.br/teses/disponiveis/3/3147/tde-29072005-140604/.

Full text
Abstract:
O presente trabalho apresenta, em primeiro lugar, um levantamento bibliográfico sobre a conceituação de “reuso de água” em todas as suas modalidades. A seguir, uma análise da situação atual desta prática na Região Metropolitana de São Paulo, apresentando estudos em andamento na Companhia de Saneamento Básico do Estado de São Paulo – Sabesp e os aspectos relativos à elaboração de legislação específica sobre o assunto no país. Dando ênfase à reutilização das águas para lavagem de veículos, apresenta o que já existe nesta área no Brasil. Descreve alguns sistemas de tratamento que propiciam a recirculação do efluente proveniente da lavagem de veículos, citando suas etapas, processos utilizados, vantagens e desvantagens. São apresentados dados técnicos relativos à implantação, funcionamento e manutenção de sistemas de reuso, observados em visitas técnicas a uma empresa de transporte de passageiros e a alguns postos de lavagem de automóveis, localizados na cidade de São Paulo. Por fim recomendam-se dois tipos de sistemas para recirculação de água proveniente da lavagem de veículos. Um desenvolvido com recursos próprios, baseado em processos de floculação e sedimentação e outro adquirido de empresa especializada que utiliza o processo de flotação. Chegando-se a conclusão de ser possível a reciclagem e o reúso de águas em empresas deste ramo de atividade, ou similares, conforme a necessidade de aplicação, reduzindo-se de 70 a 80% os custos com a água de lavagem dos veículos, adequando processos e contribuindo para a preservação do meio ambiente.
The present work presents, in the first place, a bibliographical survey on the conceptualization of "water reuse" in all its modalities. To follow, an analysis of the current situation of this practice in the São Paulo´s Metropolitan Region, presenting studies in progress in the Companhia de Saneamento Básico do Estado de São Paulo - Sabesp and the relative aspects in the Legislation on the subject in the country. It describes some of the treatment systems that make possible the recirculation of the effluent deriving from car wash, citing its stages, used processes, advantages and disadvantages. There are some technical information about the implamentation, functioning and maintenance of systems of reuse, observed in technical inspections to a company of transport of passengers and to some ranks of car wash stations, located in the city of Sao Paulo. In conclusion, there is the possibility of recycling and reusing the waters in companies in this line of activity, or similar, as the necessity of application, reducing costs (70 – 80%), adjusting processes and contributing to the preservation of the environment. Finally, two types of systems are recommended for water recirculation deriving from car wash.
APA, Harvard, Vancouver, ISO, and other styles
3

Grangeiro, Rosa Virgínia Tavares. "Caracterização da água de lavagem proveniente da purificação do biodiesel." Universidade Federal da Paraí­ba, 2009. http://tede.biblioteca.ufpb.br:8080/handle/tede/7103.

Full text
Abstract:
Made available in DSpace on 2015-05-14T13:21:24Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 764037 bytes, checksum: 7b0ce0934ba3b70cd7a8565b9ed52b66 (MD5) Previous issue date: 2009-10-30
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES
In the early 2000's it was observed an increase in the greenhouse effect, due to high levels of carbon dioxide emitted by burning fossil fuels, a fact that has concerned to climate change and affecting the entire world population. Government and scientist have established the use of biofuels as a renewable energy source with less environmental impact. However, the traditional transesterification and washing methodology to produce biodiesel use 3 liters of water for every liter of synthesized biodiesel. Thus, this study aimed develop and optimize methodologies to determine physical-chemical parameters of the water from washing of the produced biodiesel from the transesterification of soybean oil and frying oil with ethanol. The identification of esters present in this washing water was made by gas chromatography. Turbidity, pH, Chemical Oxygen Demand (COD), Biochemical Oxygen Demand (BOD) and the concentration of oils and fatty were also determined. The characterization of water for washing Biodiesels obtained from soybean oil and frying oil were carried out at the Laboratory of Fuel and Materials - LACOM, the Laboratory for Research on Environmental Chemistry - LEQA and Experiment Station Biological Treatment of Sewage (EXTRABES).
No início dos anos 2000 percebeu-se um aumento no fenômeno efeito estufa, devido aos altos níveis de gás carbônico emitidos na queima de combustíveis fósseis, fato esse que vem provocando mudanças climáticas e afetando toda população mundial. Diante da crescente tendência de se explorar os biocombustíveis como a fonte de energia renovável e com menor impacto ambiental, e considerando que nos métodos tradicionais de lavagem do biodiesel, para cada litro de biodiesel produzido, são necessários, no mínimo, 3 litros de água de lavagem, buscou-se desenvolver e otimizar metodologias para análises físico-químicas da água de lavagem do biodiesel obtido na reação de transesterificação do óleo de soja e do óleo de fritura com etanol. A identificação de alguns ésteres presentes nesta água de lavagem foi feita por cromatografia gasosa. Foram, ainda, determinados valores de pH, turbidez, Demanda Química de Oxigênio (DQO), Demanda Bioquímica de Oxigênio (DBO) e teores de óleos e graxas. A caracterização das águas de lavagem dos biodieseis obtidos a partir dos óleos de soja e fritura foi realizada no Laboratório de Combustíveis e Materiais LACOM, no Laboratório de Estudos em Química Ambiental LEQA e na Estação Experimental de Tratamento Biológico de Esgotos Sanitários (EXTRABES).
APA, Harvard, Vancouver, ISO, and other styles
4

Campos, Marlon Caianelo Dias 1986. "Influência da recirculação de água de lavagem de filtros na qualidade da água tratada para consumo humano." [s.n.], 2014. http://repositorio.unicamp.br/jspui/handle/REPOSIP/257942.

Full text
Abstract:
Orientador: Ricardo de Lima Isaac
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo
Made available in DSpace on 2018-08-24T14:00:51Z (GMT). No. of bitstreams: 1 Campos_MarlonCaianeloDias_M.pdf: 3410126 bytes, checksum: bb9db3577d3074777f6ae59b1de2ad29 (MD5) Previous issue date: 2014
Resumo: A recirculação de água de lavagem de filtro em estação de tratamento de água do tipo convencional (ETA) pode representar economia significativa tanto do recurso hídrico quanto de energia, aspecto fundamental do ponto de vista da sustentabilidade. Contudo, se praticada sem critério, tal prática operacional pode representar risco à saúde do consumidor. O objetivo geral desta pesquisa foi avaliar o impacto da recirculação da água de lavagem de filtros (ALAF) na qualidade da água tratada. O trabalho desenvolveu-se na ETA-3 de Campinas-SP que capta do manancial superficial (rio Atibaia), utiliza pré-cloração e policloreto de alumínio como coagulante no processo de tratamento. Investigou-se em escala de bancada (Jar-test) o impacto da aplicação de taxas de recirculação equivalentes a 2, 4, 6, 8 e 10 % em volume de ALAF em relação ao volume total de água tratada na formação de subprodutos de desinfecção (trihalomeanos e ácidos haloacéticos). Os parâmetros carbono orgânico total (COT), carbono orgânico dissolvido (COD), UV254, turbidez, cor (aparente e verdadeira) e metais (alumínio, bário, cádmio, chumbo, cobre, cromo, manganês, zinco e níquel) foram também avaliados. Em geral, as diferentes taxas de recirculação de ALAF não provocaram inadequações quanto ao padrão de potabilidade para os parâmetros: cor, turbidez, metais (bário, cádmio, chumbo, cobre, cromo, manganês, zinco e níquel) e trihalometanos. Quanto aos ácidos haloáceticos, porém, notou-se que não se atendeu ao valor limite estabelecido na legislação e que o aumento da taxa de recirculação provocou a elevação da concentração deste subproduto da desinfecção na água tratada
Abstract: Filter backwash water recycling at conventional water treatment plants (WTP) certainly contributes to water and energy resources rational use, essential for sustainability. However, if practiced without criteria, such operational practice may pose a risk to users¿ health. The overall objective of this research was to evaluate the impact of recirculating filter backwash water on filtered water quality. The work was carried out at Campinas WTP, Sao Paulo State, Brazil. The plant treats surface raw water from Rio Atibaia (pre-chlorination, polyaluminum chloride as main coagulant). It was investigated in lab scale (jar-test) the effect of applying recirculation flowrate corresponding to 2, 4, 6, 8 and 10 % volume of backwash water ratio to total volume of treated water on the formation of disinfection byproducts (trihalomethane, THM and haloacetic acids, HAA). Metals content (aluminum , barium, cadmium, lead, copper, chromium , manganese, zinc and nickel), total organic carbon (TOC), dissolved organic carbon (DOC) , UV254 , turbidity, apparent and true color were also evaluated . In general, tested recirculation rates did not cause filtered water quality mismatches to drinking water standards for the parameters: color, turbidity, metals (barium, cadmium, lead, copper, chromium, manganese, zinc and nickel) and THM. However, for HAA it was found that recycling led to concentration values upper than the maximum contaminant level in Brazilian drinking water standards. Increasing the rate, higher was the concentration of this disinfection by-product in treated water
Mestrado
Saneamento e Ambiente
Mestre em Engenharia Civil
APA, Harvard, Vancouver, ISO, and other styles
5

Olinger, Cristiano. "Caracterização e clarificação por sedimentação da água de lavagem de filtro rápido de uma estação de água." Florianópolis, SC, 2002. http://repositorio.ufsc.br/xmlui/handle/123456789/83820.

Full text
Abstract:
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Ambiental.
Made available in DSpace on 2012-10-20T03:42:01Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-26T01:09:09Z : No. of bitstreams: 1 193973.pdf: 14011055 bytes, checksum: 494fe92048f0a8b85d532725557a7056 (MD5)
Atualmente, as estações de tratamento de água, tem utilizado em sua maioria, os corpos receptores mais próximos ou a rede de águas pluviais como destino final para os resíduos formados durante o processo de tratamento A maior parcela destes resíduos é formada pela água proveniente da lavagem dos filtros e pode chegar, dependendo da ETA, de 1 a 5 % do volume total de água tratada. A diminuição destes resíduos formados e disposição final adequada deve ser estudada para que se possibilite a adoção destes métodos por todas as ETAs. O reaproveitamento da água de lavagem dos filtros, após sua clarificação, é importante pois contribui para o atendimento da crescente demanda de água e a diminuição do despejo, que será tratado e/ou enviado para a disposição final. Neste trabalho foi estudada a caracterização da água de lavagem dos filtros de uma ETA que utiliza sulfato de alumínio como coagulante primário. Através desses ensaios verficam-se a possibilidade de reaproveitamento da água de lavagem dos filtros, mediante a recirculação de parte desta água que possui após algum tempo qualidade superior a água aduzida a ETA e também a viabilidade de clarificação por sedimentação da água de lavagem.
APA, Harvard, Vancouver, ISO, and other styles
6

Santos, Juliana Marisa Ferreira dos. "Estudo da relação entre o caudal e indicadores de qualidade da água no Médio Vouga." Master's thesis, Universidade de Aveiro, 2008. http://hdl.handle.net/10773/584.

Full text
Abstract:
Mestrado em Engenharia do Ambiente
A presente dissertação tem como principal objectivo a caracterização hidroquímica e da qualidade da água da bacia hidrográfica do médio Vouga direito, tendo em vista a avaliação de riscos de incumprimento da qualidade na captação do Carvoeiro. O troço do Rio Vouga estudado tem início na foz do rio Zela, estende-se ao longo de 40 km, com uma área de drenagem de 417 km2, e termina no Carvoeiro, onde existe um Sistema de Abastecimento de água à escala Regional. Foram seleccionados 15 pontos de amostragem na área da bacia estudada, tendo em conta a acessibilidade e essencialmente a representatividade de distribuição de possíveis fontes poluidoras. Foram amostrados pontos no troço principal do Rio Vouga e também nos principais afluentes do Rio Vouga, nomeadamente no rio Mau, rio Teixeira, rio Varoso e rio Zela. Os parâmetros medidos "in situ” foram a temperatura, o oxigénio dissolvido, a condutividade, a turbidez, a ficocianina e a clorofila a. Para análise em laboratório foram recolhidas amostras de água e analisados os seguintes parâmetros indicadores da qualidade da água: sólidos suspensos totais e voláteis, amónia, CBO5, nitratos, fósforo total e solúvel, azoto total e orgânico. Nos dias de amostragem, quando foi possível, foram medidos os caudais em dois afluentes do rio Vouga, a ribeira da Alombada e o Rio Mau, e também no Carvoeiro (rio Vouga). Este facto constitui um dos objectivos deste trabalho, que consiste em verificar a relação que existe entre o caudal do rio e os indicadores da qualidade da água acima enunciados. Para isso aplicou-se o modelo matemático EPA-SWMM para simular o caudal do rio ao longo de todo o troço estudado até ao Carvoeiro. Os resultados mostram que a bacia do médio Vouga apresenta problemas de poluição, em particular no troço entre Vouzela e a ponte de Pessegueiro, sendo os valores mais elevados de nutrientes observados em Sejães. Esta degradação da qualidade está relacionada com a actividade agrícola na bacia e com as descargas de efluentes domésticos. Com o aumento do caudal do rio em Abril observa-se uma melhoria da qualidade da água. No entanto, os SST constituem um problema. ABSTRACT: The present dissertation focuses on the hydrochemistry and water quality characterization of the river Vouga basin, aiming at evaluating the risks associated with not fulfilling the quality in the caption of Carvoeiro. The studied section of river Vouga, starts at the estuary of river Zela and it is extended over a length of 40 km, with a catchment area of 417 km2, discharging into Carvoeiro, where exists a water supplying system to the regional scale. In the studied basin's area, 15 sampling points had been detected, taking into account the accessibility and, essentially, the representation of distribution of possible polluting sources. Additionally, sampling points were retrieved in the main section of river Vouga and also on its main tributaries, particularly in river Mau, river Teixeira, river Varoso and river Zela. The measured parameters “in situ” were the temperature, the dissolved oxygen, the conductivity, the turbidity, the phycocyanin and the chlorophyll. For laboratory analysis, water samples were collected aiming at analyzing the following pointers of quality of the water: total and volatile suspended solids, ammonia, BOD5, nitrates total and water-soluble phosphorus and, finally, total and organics nitrogen. In the sampling days, whenever possible, it was measured the outflow in two tributaries of river Vouga, Ribeira da Alombada and river Mau, and also at Carvoeiro (River Vouga). This was one of the main goals of this project, which consists of verifying the relation between the outflow of the river and the pointers of quality of the water mentioned above. For this, it was used a mathematical model EPA-SWMM, to simulates the outflow of the river throughout the studied section, finishing at Carvoeiro. The results show that the river Vouga basin in the medium reach, presents some pollution problems, particularly in a river stretch between Vouzela and Pessegueiro, and the higher values of nutrients found in Sejães. This deterioration of water quality is closely related to the agricultural activities within the basin, as well to domestic wastewater discharges. With the increase in the flow of the river in April there is an improvement of water quality. However, the SST is a problem.
APA, Harvard, Vancouver, ISO, and other styles
7

Frigieri, Tânia Cristina. "O efeito da redução de água na lavagem da polpa Kraft no branqueamento ECF /." Guaratinguetá : [s.n.], 2012. http://hdl.handle.net/11449/94444.

Full text
Abstract:
Orientador: Gustavo Ventorim
Coorientador: José Claudio Caraschi
Banca: Maria Angelica Martins Costa
Banca: Claudio Angeli Sansígolo
Resumo: O objetivo principal do presente trabalho foi estudar a viabilidade técnica de se usar o efluente da lavagem do branqueamento da celulose, nas diversas etapas do processo, visando uma redução no consumo de água fresca na lavagem da polpa avaliando seu efeito na qualidade da polpa. Foi utilizada polpa celulósica industrial de Eucalyptus spp. deslignificada com oxigênio. Foi feita a mesma sequência de branqueamento D(E+P)DP dez vezes, nas mesmas condições (temperatura, consistência e tempo). Utilizou-se a lavagem em contra-corrente nos estágios de branqueamento, cada sequência foi feita com um diferente fator de lavagem: 9, 6, 3 e 0 m³ de água destilada por tonelada de polpa, buscando atingir a alvura de 92 ± 0,5% ISO. As dez sequências realizadas foram uma busca da estabilidade da carga orgânica do efluente medida pela DQO e então comparados os resultados da DQO com os resultados referentes à qualidade final da polpa. Após o branqueamento foram analisadas os seguintes parâmetros: alvura, viscosidade, nº kappa, reversão de alvura, DQO e cor aparente. Os resultados avaliados das dez sequências e nas quatro diferentes lavagens, mostrou o aumento da DQO por causa do acúmulo da matéria orgânica decorrente da reutilização dos efluentes das sequências anteriores. Este aumento da DQO fez com que os resultados da alvura baixassem durante os ciclos e também na redução da água de lavagem, provando a necessidade de que haja lavagem entre os estágios de branqueamento. Os resultados da reversão de alvura aumentaram junto com o aumento da DQO, mas nas últimas sequências houve uma queda mostrando um princípio de estabilização da reversão de alvura. A viscosidade e número kappa não tiveram variação, mostrando que estes não são influenciados com o acréscimo da DQO na água de lavagem. A cor aparente sofreu um... (Resumo completo, clicar acesso eletrônico abaixo)
Abstract: The main objective of this work was studying the technical viability of using the effluent from the washing of the pulp bleaching, at several stages of the process, seeking a reduction in fresh water consumption in the pulp washing evaluating its effect on pulp quality. It was used industrial pulp from Eucalyptus spp. oxygen delignified. It was applied the same bleaching sequence D(E+P)DP ten times, under the same conditions (temperature, consistency and time). It was used the washing in counter-current on the stages of bleaching, each sequence with a different washing factor: 9, 6, 3, 0 m³ of distilled water per tone of pulp, trying to achieve a brightness of 92 ± 0,5% ISO. The ten sequences were performed searching the stability of the organic load of the effluent measured by the COD and then the COD results were compared with the results of the final quality of the pulp. After the bleaching it was analyzed the following parameters: brightness, viscosity, kappa number, brightness reversion, COD and apparent color. The evaluated results from the ten sequences and in four different washes, showed an increasing in COD because of the organic load accumulation resulting from the reuse of effluent from previous sequences. This COD increasing provided the lower brightness results during the cycles and also reduction in washing water, evidencing the necessity of washing between the bleaching stages. The results of the brightness reversion increased with the COD increasing, but in the last sequences there were a decreasing showing a beginning the brightness reversion stabilization. There were not variation on the viscosity and kappa number, showing that they are not influenced by the COD addition in the washing water. The apparent color had a large increase with a COD increasing in the effluent during the cycles and also with the... (Complete abstract click electronic access below)
Mestre
APA, Harvard, Vancouver, ISO, and other styles
8

Frigieri, Tânia Cristina [UNESP]. "O efeito da redução de água na lavagem da polpa Kraft no branqueamento ECF." Universidade Estadual Paulista (UNESP), 2012. http://hdl.handle.net/11449/94444.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:27:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-06-26Bitstream added on 2014-06-13T19:55:28Z : No. of bitstreams: 1 frigieri_tc_me_guara.pdf: 2603761 bytes, checksum: 1aa905c25fa37da4bf3f378334d0e8e2 (MD5)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
O objetivo principal do presente trabalho foi estudar a viabilidade técnica de se usar o efluente da lavagem do branqueamento da celulose, nas diversas etapas do processo, visando uma redução no consumo de água fresca na lavagem da polpa avaliando seu efeito na qualidade da polpa. Foi utilizada polpa celulósica industrial de Eucalyptus spp. deslignificada com oxigênio. Foi feita a mesma sequência de branqueamento D(E+P)DP dez vezes, nas mesmas condições (temperatura, consistência e tempo). Utilizou-se a lavagem em contra-corrente nos estágios de branqueamento, cada sequência foi feita com um diferente fator de lavagem: 9, 6, 3 e 0 m³ de água destilada por tonelada de polpa, buscando atingir a alvura de 92 ± 0,5% ISO. As dez sequências realizadas foram uma busca da estabilidade da carga orgânica do efluente medida pela DQO e então comparados os resultados da DQO com os resultados referentes à qualidade final da polpa. Após o branqueamento foram analisadas os seguintes parâmetros: alvura, viscosidade, nº kappa, reversão de alvura, DQO e cor aparente. Os resultados avaliados das dez sequências e nas quatro diferentes lavagens, mostrou o aumento da DQO por causa do acúmulo da matéria orgânica decorrente da reutilização dos efluentes das sequências anteriores. Este aumento da DQO fez com que os resultados da alvura baixassem durante os ciclos e também na redução da água de lavagem, provando a necessidade de que haja lavagem entre os estágios de branqueamento. Os resultados da reversão de alvura aumentaram junto com o aumento da DQO, mas nas últimas sequências houve uma queda mostrando um princípio de estabilização da reversão de alvura. A viscosidade e número kappa não tiveram variação, mostrando que estes não são influenciados com o acréscimo da DQO na água de lavagem. A cor aparente sofreu um...
The main objective of this work was studying the technical viability of using the effluent from the washing of the pulp bleaching, at several stages of the process, seeking a reduction in fresh water consumption in the pulp washing evaluating its effect on pulp quality. It was used industrial pulp from Eucalyptus spp. oxygen delignified. It was applied the same bleaching sequence D(E+P)DP ten times, under the same conditions (temperature, consistency and time). It was used the washing in counter-current on the stages of bleaching, each sequence with a different washing factor: 9, 6, 3, 0 m³ of distilled water per tone of pulp, trying to achieve a brightness of 92 ± 0,5% ISO. The ten sequences were performed searching the stability of the organic load of the effluent measured by the COD and then the COD results were compared with the results of the final quality of the pulp. After the bleaching it was analyzed the following parameters: brightness, viscosity, kappa number, brightness reversion, COD and apparent color. The evaluated results from the ten sequences and in four different washes, showed an increasing in COD because of the organic load accumulation resulting from the reuse of effluent from previous sequences. This COD increasing provided the lower brightness results during the cycles and also reduction in washing water, evidencing the necessity of washing between the bleaching stages. The results of the brightness reversion increased with the COD increasing, but in the last sequences there were a decreasing showing a beginning the brightness reversion stabilization. There were not variation on the viscosity and kappa number, showing that they are not influenced by the COD addition in the washing water. The apparent color had a large increase with a COD increasing in the effluent during the cycles and also with the... (Complete abstract click electronic access below)
APA, Harvard, Vancouver, ISO, and other styles
9

Lobo, Tatiane Martins. "Obtenção do SrSnO3 e do SrSnO3:N para o tratamento fotocatalítico da água de lavagem do biodiesel." reponame:Repositório Institucional da UnB, 2015. http://dx.doi.org/10.26512/2015.12.T.20302.

Full text
Abstract:
Tese (doutorado)—Universidade de Brasília, Instituto de Química, Programa de Pós-Graduação em Química, 2015.
Submitted by Fernanda Percia França (fernandafranca@bce.unb.br) on 2016-04-28T18:03:06Z No. of bitstreams: 1 2015_TatianeMartinsLobo_Parcial.pdf: 1754112 bytes, checksum: 677321c4f2d260010d6c779f92532a30 (MD5)
Approved for entry into archive by Patrícia Nunes da Silva(patricia@bce.unb.br) on 2016-05-18T12:56:26Z (GMT) No. of bitstreams: 1 2015_TatianeMartinsLobo_Parcial.pdf: 1754112 bytes, checksum: 677321c4f2d260010d6c779f92532a30 (MD5)
Made available in DSpace on 2016-05-18T12:56:26Z (GMT). No. of bitstreams: 1 2015_TatianeMartinsLobo_Parcial.pdf: 1754112 bytes, checksum: 677321c4f2d260010d6c779f92532a30 (MD5)
O estanato de estrôncio, SrSnO3, é um material cerâmico que apresenta uma estrutura ortorrômbica, compatível com uma perovsquita distorcida, e tem sido bastante estudado em função de sua variada aplicação, inclusive como fotocatalisador. Neste trabalho, o SrSnO3 foi sintetizado por reação de combustão e estado sólido e, posteriormente, nitretado por reação de amonólise gasosa para promover a atividade fotocatalítica na região do visível. Testes fotocatalíticos, com radiação UV e visível, foram usados para avaliar a atividade fotocatalítica do SrSnO3 e do SrSnO3:N, investigando, primeiramente, a oxidação do corante azul de metileno como reação sonda (probereaction) e, na sequência, a degradação da matéria orgânica residual do processo de lavagem de biodiesel.Observou-se que os métodos de síntese não influenciaram no teor de nitrogênio das amostras nitretadas. No entanto, os resultados sugerem que a incorporação do N acontece na superfície do SrSnO3 e que ocorrem diferentes mecanismos de compensação de cargas. Apesar disso, a nitretação do SrSnO3, conduzida a diferentes condições, aumentou a área superficial, a desordem a curto alcance e a atividade fotocatalítica no visível. Para o corante, o SrSnO3:N apresentou menor atividade fotocatalítica comparado ao TiO2 quando se utiliza luz UV. Contudo, ao usar luz visível, os oxinitretos apresentaram eficiência fotocatalítica aproximadamente 7 vezes maior comparada com o SrSnO3 e 4 vezes maior comparada ao TiO2. No tratamento fotocalítico, observou-se que a água de lavagem é uma matriz muito complexa e com elevada carga orgânica, a qual tem uma fração de difícil degradação. Tanto a fotólise como a fotocatálise degradaram, sob radiação UV em até 4 h de reação, uma fração significativa da matéria orgânica, entretanto, parte do TOG permaneceu no efluente após os tratamentos. Com radiação visível, apenas o SrSnO3:N degradou eficientemente os poluentes presentes na água residual. Além disso, os ensaios de toxicidade indicaram que a fotólise/UV torna a água mais tóxica aos embriões do Danioreriose comparada à fotocatálise. Deste modo, o uso do SrSnO3:N irradiado com luz visível torna-se mais interessante, pois reduziu até 57,4% de COT (contudo, a ecotoxicidade deste sistema não pôde ser avaliada). De forma geral, foi possível observar que a nitretação do SrSnO3 aumentou a absorção de luz visível e que os SrSnO3:N produzidos são promissores fotocatalisadores para a fotodegradação de corantes orgânicos e de água residual de biodiesel, podendo ser usado como fotocatalisador ativo com luz solar.
Strontium stannate, SrSnO3, is a ceramic material which presents an orthorhombic structure, compatible with a distorted perovskite. It has been extensively studied due to its potential to several application, including application as a photocatalyst. In this work, SrSnO3 was synthesized by combustion and solid state reaction. Subsequently, the samples were submitted to a thermal treatment under NH3 in order to obtain the oxynitride and then to promote photocatalytic activity in the visible region. Photocatalytic activity of SrSnO3 and SrSnO3:N were evaluated under UV and visible radiation. First of all, oxidation of the dye methylene blue was investigated as a probe reaction and then SrSnO3 and SrSnO3:N were employed to degrade the residual organic matter from the washing process of biodiesel. The synthesis methods showed to not influence in the N content of nitrided samples. Moreover, the results suggest that the incorporation of N occurs preferencially at the surface of the SrSnO3 and that it occurs by two different mechanism of charge compensation. Nevertheless, the SrSnO3nitridation, performed at different conditions, increases the specific surface area, the short-range order and the photocatalytic activity under visible light. For the methylene blue, using UV light, the SrSnO3:N showed a smaller photocatalytic activity if compared to TiO2.. However, using visible light, the oxinitrides presented the better photocatalytic performance (7 times higher than non-nitred samples and 4 times higher than TiO2. For biodiesel wastewater treatment it was observed that wasterwater is a very complex substrate with a very high organic content. Part of this organic content is quite difficult to be oxidized. Either photolysis andphotocatalysis could reduce significantly the TOC content after 4h of UV irradiation, nevertheless a residual part of organic matter (probably oils and grease) remained after both treatment. Using visible radiation, only the SrSnO3:N, obtained through both methods of synthesis, could degrade pollutants present in the wastewater. Moreover, acute ecotoxicity tests indicated that the direct photolysis/UV makes the wastewater even more toxic to the Danio rerio embryos than photocathalysis. Thus, SrSnO3:N/Vis becomes an even more attractive option, reducing up to 57.4% of TOC (although the ecotoxicity test of this treatment could not be performed). In general, it was possible to observe that the nitridation of SrSnO3 increases the absorption of visible light and the SrSnO3:N produced are promising photocatalysts for the photodegradation of organic dye and the wastewater from biodiesel, being used as an active photocatalyst with sun light.
APA, Harvard, Vancouver, ISO, and other styles
10

Grangeiro, Rosa Virgínia Tavares. "Avaliação dos tratamentos oxidativos avançados em água de lavagem de biodiesel e ensaios de fitoxicidade." Universidade Federal da Paraí­ba, 2014. http://tede.biblioteca.ufpb.br:8080/handle/tede/7144.

Full text
Abstract:
Made available in DSpace on 2015-05-14T13:21:37Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 1224120 bytes, checksum: f64c0391dc1efdba15b19e77bab0b144 (MD5) Previous issue date: 2014-05-09
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES
Given the growing trend to explore biofuels as a renewable energy source with less environmental impact and considering thatthe transesterification by basic catalysis is the most used in the biodiesel purification, it becomes importantperform treatments order to reuse of wash water biodiesel. In this sense, the objective of this study was to apply and compare photolysis (UV) followed by advanced oxidation treatment; UV/H2O2; Fenton (Fe2+/H2O2) and photo-Fenton (Fe2+/UV/H2O2)as well as perform toxicity tests using seeds lettuce (Lactuca sativa) before and after treatment of effluents.washing water was collected in biodiesel industry located in Caetés - PE. Biodiesel obtained from cotton oil was washed sequentially with two portions of one hundred liters of water. It was found pH values of 3.8 and 3.4; The minimum turbidity of 158 NTU and a maximum of 7.369 and EC was 0.25 and 0.86, minimum of 160,000 and maximum of 184.000 mg.L-1 COD, BOD ranging 830 and 2,150 mg.L-1 and the content of oils and greases varied 2,852 and 21,761 mg.L-1, respectively for first and second washing water. After application of photolysis process, reduction occurred (82.6% and 72.5%) for the water turbidity resulting from two washes.For the first rinse water, UV/H2O treatment resulted in a reduction of turbidity (91.4%) and COD (70.4%). For water resulting from second wash, reduced turbidity (84%) and in COD (80%), determined by photo-Fenton process. Through toxicity tests using lettuce seeds, it was proven that the best IG% occurred in treatments photolysis (95.3%) and UV/H2O2 (92.8%)
Diante da crescente tendência de se explorar os biocombustíveis como a fonte de energia renovável e com menor impacto ambiental e considerando que a transesterificação pela catálise básica é a mais utilizada na purificação do biodiesel, torna-se relevante realizar tratamentos visando à reutilização da água de lavagem do biodiesel. Neste sentido, o objetivo deste trabalho foi aplicar e comparar aFotólise (UV)seguidados tratamentos oxidativos avançados; UV/H2O2; Fenton (Fe2+/H2O2) e foto-Fenton (Fe2+/UV/H2O2), bem como realizar ensaios de toxicidade usando sementes de alface (lactuca sativa), antes e após o tratamento dos efluentes. A água de lavagem foi coletada na usina de biodiesel localizada na cidade de Caetés PE. O biodiesel obtido a partir do óleo de algodão foi lavado, sequencialmente, com duas porções de cem litros de água. Foram encontrados valores de pH de 3,8 e 3,4; a turbidez apresentou valor mínimo de 158 e máximo de 7369 UNT; a CE foi de 0,25 e 0,86; o valor mínimo de 160.000 e máximo de 184.000 mg.L-1de DQO; a DBO variou de 830 a 2.150 mg.L-1 e o teor de óleos e graxas oscilaram de 2.852 a 21.761 mg.L-1, respectivamente, para água de primeira e segunda lavagem. Após a aplicação do processo por fotólise, ocorreu redução (82,6% e 72,5%) da turbidez para as águas resultantes das duaslavagens. Para a água da primeira lavagem, o tratamento por UV/H2O2 resultou na melhor redução da turbidez (91,4%) e DQO (70,4%). Para a água resultante da segunda lavagem a turbidez reduziu em (84%) e a DQO em (80%), determinadas pelo processo de foto-Fenton.Através dos testes de toxicidade utilizando sementes de alface, ficou comprovado que o melhor IG% ocorreu nos tratamentos por fotólise (95,3%) e UV/H2O2 (92,8%)
APA, Harvard, Vancouver, ISO, and other styles
11

Etchepare, Ramiro Gonçalves. "Integração de processos no tratamento de efluentes de lavagem de veículos para reciclagem de água." reponame:Biblioteca Digital de Teses e Dissertações da UFRGS, 2012. http://hdl.handle.net/10183/60673.

Full text
Abstract:
Foram estudados processos integrados para o tratamento e reciclagem de água de um lava rápido comercial (LRC) e de efluentes de um posto de manutenção de locomotivas (PML), em nível de bancada e piloto. Os processos envolvidos foram a floculação-flotação em coluna, seguida de filtração em areia (FFC-A) e polimento com hipoclorito de sódio e adsorção em carvão ativado. A caracterização dos efluentes do LRC, com amostras coletadas afluentes de um separador (caixa) água-óleo – SAO, analisou concentrações médias de surfactantes de 20 mg.L-1 (dez vezes superiores ao limite de emissão local – 2 mg.L-1), baixas tensões superficiais (33 mN.m-1), cargas orgânicas moderadas (DQO = 239 mg.L-1 e DBO = 104 mg.L-1) e concentrações de coliformes totais de 2,4E+06 N.M.P.100mL-1 e de E. coli de 5,2E+02 N.M.P.100mL-1. O estudo de reciclagem de água no LRC foi dividido em duas campanhas. Na Campanha 1, com o processo FFC-A, a água de reúso apresentou uma alta clarificação (turbidez = 8 NTU). Entretanto, os resultados mostraram uma tendência de aumento tanto da concentração da DBO como da condutividade do efluente em função dos ciclos de água. Foi verificada ainda, uma alta concentração de coliformes totais e de E. coli no efluente, que foram causadores, entre outros fatores, de maus odores na pista de lavagem. Na Campanha 2, com a inclusão de uma cloração final (hipoclorito de sódio) ao tratamento proposto (FFC-AC), os coliformes totais e E. coli foram reduzidos em 92 e 96%, respectivamente, e além da elevada clarificação na água de reúso (turbidez média de 10 NTU), os odores não foram perceptíveis. Ao longo de todo o estudo no LRC, um percentual de reciclagem de água próximo a 70% foi alcançado, com mais de 2800 carros lavados usando um volume médio de 130 L por veículo. As principais vantagens do sistema incluíram a redução de emissão de efluentes na rede de drenagem pluvial e do consumo de água potável, utilizada apenas no enxágue final dos veículos como água de makeup. O risco microbiológico do efluente e da água de reúso do LRC foi estimado com a utilização de um modelo do tipo beta-Poisson e o micro-organismo E. coli como agente etiológico. Os resultados mostraram que, em um cenário de exposição dos usuários (clientes) do LRC, o risco foi sempre baixo. Entretanto, esse risco foi relativamente alto (1,0E-01, no caso do efluente e 3,7E-03, para a água de reúso) para os operadores. Um limite de 200 N.M.P.100 mL-1 de E. coli na água de reúso foi proposto para que o risco aos operadores seja aceitável (10-3) e uma dosagem de hipoclorito de sódio em concentrações entre 15 e 20 mgCl2.L-1 (obtida em estudos de bancada) foi sugerida para atingir este nível de desinfecção. A partir deste aprimoramento da dosagem de cloro e testes de jarros em laboratório com diferentes reagentes (polímero base tanino – PBT e cloreto de polialuminio – PAC), foi aplicado um balanço de massa para estimar as concentrações de parâmetros de qualidade na água de reúso com o aumento do número de ciclos de água. Os resultados indicaram que, para 70% de reciclagem de água, as concentrações de SDT e de íons cloreto estabilizaram a partir do 40° ciclo para os dois reagentes avaliados e foram menores que os valores limites de referência da literatura (SDT = 1000 mg.L-1 e íons cloreto = 400 mg.L-1), sugerindo um baixo potencial corrosivo desta água tratada. Uma pré-avaliação econômica operacional do sistema de reciclagem de água mostrou que o payback do equipamento FFC-A poderia ocorrer em um tempo próximo de 62 meses. Com relação aos estudos realizados no PML, foram observadas as seguintes características do efluente: pH alcalino, baixa biodegradabilidade, elevada carga orgânica (DQO = 1608 mg.L-1 e DBO = 525 mg.L-1) e de surfactantes (17 mg.L-1) e a presença de micro-organismos fecais (E. coli = 2,4E+05 NMP.100mL-1). O efluente não atendeu aos padrões de emissão local dos parâmetros pH, DBO, DQO, SST, óleos e graxas, surfactantes, sulfetos e fósforo, o que mostra um alto potencial poluidor aos corpos receptores. O tratamento proposto em nível piloto, com etapas de equalização, coagulação e processo FFC-A, foi altamente eficiente na remoção/redução dos parâmetros: turbidez (97%), SST (91%), DQO (76%), DBO (70%), fósforo (80%), nitrogênio (57%), sulfeto (76%) e óleos e graxas (51%). Com exceção a DQO, DBO e surfactantes, os demais parâmetros de qualidade monitorados foram enquadrados nos limites de emissão, sendo que um polimento com carvão ativado (3 kg.m-3, pH 7 e tr = 30 min), em nível de bancada, possibilitaria o enquadramento de todos os parâmetros analisados do efluente final aos limites de emissão locais (Resolução Consema n.° 128/2006). Os estudos de cloração com hipoclorito de sódio em laboratório indicaram uma dosagem de cloro muito elevada (200 mg.L-1) para assegurar uma desinfecção efetiva do efluente tratado no PML. Acredita-se que o presente trabalho contribuiu para o embasamento técnico de processos e para a definição de parâmetros específicos de qualidade de água de reúso na lavagem de veículos, contribuindo para a elaboração de leis com parâmetros de controle de qualidade e propiciando informação técnica aos setores acadêmicos e produtivos.
This work presents studies integrating processes for the wastewater treatment and water reuse in a commercial car wash (CCW) and locomotives maintenance station (LMC), at bench and pilot scales. The processes consisted of a flocculation column-flotation, followed by sand filtration (FCF-S) and polishing with sodium hypochlorite and/or adsorption on activated carbon. The characterization of the wastewater of the CCW, with samples collected after an oil-water separator device (API) showed mean concentrations values of surfactants of about 20 mg.L-1 (ten times higher than the local emission limit – 2 mg.L-1), low surface tension (33 mN.m-1), moderate organic load (DQO = 239 mg.L-1 e DBO = 104 mg.L-1) and high concentrations of total coliforms (2,4E+06 N.M.P.100mL-1) and E. coli (5,2E+02 N.M.P.100mL-1). The application of water recycling at the CCW was divided into two distinct campaigns. Campaign 1, with the FCF-S process, yielded a reclaimed water with high clarification (turbidity = 8 NTU). Yet, results showed a trend of buildup both in the concentration of BOD and conductivity of the feed wastewater as a function of water cycles. It was also observed a high concentration of total coliforms and E. coli in the wastewater, which were the cause, among other factors, of odors at the car wash pit. In Campaign 2, with the inclusion of a final chlorination (FCF-SC), the total coliforms and E. coli were reduced by 92 and 96%, respectively (2 log removal), in addition to the high clarification of the reclaimed water (average turbidity of 10 NTU), the odors were not noticeable. During the whole study at the LRC, a percentage of water recycling close to 70% was reached for more than 2700 cars washed with an average volume of 130 L per vehicle. The main advantages of the system included the reduction of both: wastewater emission in the storm water drainage network (there was no discharge during both campaigns) and consumption of fresh water, used only in the final rinse of the vehicles as makeup water. The microbiological risk of wastewater and reclaimed water of the CCW was estimated using a beta-Poisson model and the microorganism E. coli as the etiological agent. The results showed that in an exposure scenario of users (customers) of the CCW, the risk was always low. However, these risks were relatively high (10-3 in the case of the wastewater and 10-3 for the reclaimed water) for the operators. Thus, a limit of 200 CFU.100mL-1 of E. coli in the reclaimed water has been proposed so that the risk is acceptable to the operators (10-3) and a dose of sodium hypochlorite at concentrations between 15 and 20 mgCl2.L-1 (obtained in bench-studies) was suggested to reach this level of disinfection. After determining chlorine dosage and after jar-tests at laboratory with different reagents (tannin based polymer - TBP and polyaluminium chloride - PAC), it was applied a mass balance to estimate the concentrations of water quality parameters in the reclaimed water with increasing water cycles. The results indicated that, by fixing the percentage of water recycling at 70%, the TDS and chloride concentrations stabilized after 40 water cycles for the two evaluated reagents and these values were lower than literature reference limits (TDS = 1000 mg.L-1 and chloride = 400 mg.L-1), suggesting a low corrosion potential of this treated water. A preliminary economic-operational assessment of the proposed water recycling system showed that the payback of the FCF-S equipment could occur within a period of time close to 62 months. Regarding the studies at the LMS, the following characteristics of the wastewater were observed: alkaline pH, low biodegradability, high organic load (COD = 1608 mg.L-1 and BOD = 525 mg.L-1);17 mg.L- 1 surfactants concentration and the presence of coliform organisms (E. coli = 2,4E+05 NMP.100mL-1). Thus, the wastewater did not meet the local emission limits of the parameters pH, BOD, COD, TSS, oil and grease, surfactants, phosphorus and sulfide, which shows a high pollution potential for the receiving water bodies. The treatment conducted at pilot-scale, with stages of equalization, coagulation and FCF-S process resulted in a high efficiency for the removal/reduction of the parameters: turbidity (97%), TSS (91%), COD (76%), BOD (70 %), phosphorus (80%), nitrogen (57%), sulfide (76%) and oil and grease (51%). With the exception of COD, BOD and surfactants, other monitored parameters were below the standard emission limits, and a polishing stage with activated carbon (3 kg.m-3, pH 7 and 30 min of contact), at bench level, would allow a discharging water having those parameters meeting the local environmental standards. The breakpoint chlorination studies in laboratory indicated a very high dosage of chlorine (200 mg.L-1) to ensure effective disinfection of the treated wastewater in the LMS. This work contributed for technical advances of processes assisting the specification of the quality parameters in reclaimed water for washing vehicles; contribute for the development of legislation on quality control parameters (especially those related to microbiological risks) and provides technical information for the academic and industrial sectors.
APA, Harvard, Vancouver, ISO, and other styles
12

Grandi, Adriana Maria de. "Avaliação de duas centrífugas para remoção da água superficial do café." Universidade Federal de Viçosa, 2003. http://www.locus.ufv.br/handle/123456789/9602.

Full text
Abstract:
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2017-02-21T17:31:04Z No. of bitstreams: 1 texto completo.pdf: 744337 bytes, checksum: 9d778d70a8e7983488cb4c8ff11a55be (MD5)
Made available in DSpace on 2017-02-21T17:31:04Z (GMT). No. of bitstreams: 1 texto completo.pdf: 744337 bytes, checksum: 9d778d70a8e7983488cb4c8ff11a55be (MD5) Previous issue date: 2003-03-24
Conselho Nacional de Desenvolvimento Científico e Tecnológico
Com o objetivo de avaliar o processo de centrifugação na retirada da água superficial do café e estabelecer as melhores rotações para centrifugação foram testadas duas diferentes centrífugas, desenvolvidas no Departamento de Engenharia Agrícola da UFV. Para a avaliação conduziram-se testes de centrifugação com a centrífuga I, utilizando café cereja desmucilado e seis diferentes rotações (300, 400, 500, 600, 700 e 800 rpm). Os parâmetros observados foram teor de umidade, massa específica, porcentagem de grãos danificados (PGD) e capacidade da centrífuga. Para os testes com a centrífuga II, utilizou-se café cereja desmucilado, café bóia e café seco posteriormente molhado durante 1, 2 e 3 horas com rotações de 300, 400 e 500 rpm e tempos de centrifugação de 30, 45 e 60 segundos. Com base nos resultados obtidos nos testes, pode-se concluir que: o processo de centrifugação contribui para a remoção da água superficial do café; as melhores rotações considerando a maior perda de água do produto, a menor PGD e a maior capacidade da centrífuga foram as de 500 e 600 rpm (centrífuga I) e; para a centrífuga II a melhor rotação para remoção da água superficial do café foi a de 500 rpm.
Aiming at the evaluation of the centrifugation process in removing the superficial water from coffee, as well as to establish the best rotation for this process, two different centrifuges, which were developed at the UFV Agricultural Engineering Department, were tested. For this evaluation, some centrifugation tests were conducted with the centrifuge I, using pulped coffee cherries and six different rotations (300, 400, 500, 600, 700 and 800 rpm). The following parameters were observed: moisture content, specific mass, damaged beans percentage (PGD) and the centrifuge capacity. To carry out the tests with centrifuge II, the pulped coffee cherries, “bóia” coffee, and the dry coffee that was latter soaked into water for 1, 2 and 3 hours at the rotations of 300, 400 and 500 rpm and centrifugation times of 30, 45 and 60 seconds were used. According to the results, the following conclusions were drawn: the centrifugation process contributes to the removal of the superficial water in the coffee berries; the best rotations concerning to the highest water loss of the product, the lowest percentage of the damaged coffee beans; and the highest centrifuge capacity were 500 and 600 rpm for centrifuge I, whereas for centrifuge II the best rotation for removal of the superficial water in the coffee beans was 500 rpm.
Tese importada do Alexandria
APA, Harvard, Vancouver, ISO, and other styles
13

Brito, Gabriel Ferreira da Silva. "Avaliação dos processos Fenton e foto-Fenton no tratamento da água de lavagem do biodiesel de soja." reponame:Repositório Institucional da UnB, 2015. http://dx.doi.org/10.26512/2015.12.D.19935.

Full text
Abstract:
Dissertação (mestrado)—Universidade de Brasília, Instituto de Química, Programa de Pós-Graduação em Química, 2015.
Submitted by Fernanda Percia França (fernandafranca@bce.unb.br) on 2016-04-08T19:23:26Z No. of bitstreams: 1 2015_GabrielFerreiradaSilvaBrito.pdf: 1570431 bytes, checksum: 3c70ee2798874853f1aa56156eb0b454 (MD5)
Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2016-04-12T20:12:37Z (GMT) No. of bitstreams: 1 2015_GabrielFerreiradaSilvaBrito.pdf: 1570431 bytes, checksum: 3c70ee2798874853f1aa56156eb0b454 (MD5)
Made available in DSpace on 2016-04-12T20:12:37Z (GMT). No. of bitstreams: 1 2015_GabrielFerreiradaSilvaBrito.pdf: 1570431 bytes, checksum: 3c70ee2798874853f1aa56156eb0b454 (MD5)
O processo de produção do biodiesel merece atenção quanto à geração de resíduos. A etapa de purificação do biodiesel é geradora de grandes volumes de água de lavagem, numa proporção de até 1:3 biodiesel:água de lavagem. Considerando o crescimento atual na produção de biodiesel e consequentemente o volume gerado da água de lavagem, é de grande importância o eficiente tratamento deste resíduo impedindo que ele chegue aos corpos hídricos na sua forma bruta. Devido ao seu baixo custo e elevada taxa de degradação de compostos orgânicos em soluções aquosas, os processos oxidativos avançados Fenton e foto-Fenton apresentam-se como boas alternativas para o tratamento da água de lavagem do biodiesel e, por este motivo foram avaliados neste trabalho. As amostras de água de lavagem foram obtidas em escala laboratorial e caracterizadas. Apresentaram teor de COT de 40700 ± 570 mg L-1; TOG de 2237 ± 204 mg L-1; DQO de 24210 ± 265 mg L-1 e valor de CL50 para o teste FET de 0,118 % em pH 7. Foram avaliadas as melhores concentrações de Fe(II) e H2O2 pelo processo Fenton, que foi realizado utilizando como fonte de ferro o FeSO4⋅7H2O, para obter uma concentração de Fe2+ de 20 mg L-1 e 250 μL de volume de peróxido de hidrogênio 30 % v/v adicionado a cada 15 min em 100 mL de amostra sob agitação constante, devido ao seu desempenho e menor impacto ambiental. O processo foto-Fenton foi realizado utilizando as mesmas concentrações para o Fenton, porém dentro de um reator caseiro sob irradiação de uma lâmpada de vapor de mercúrio de média pressão de potência de 125 W sem o bulbo. Para avaliar a influência da luz e do peróxido, os processos UV e UV/H2O2 também foram avaliados. Amostras foram coletadas periodicamente para avaliação do COT até 300 min para o Fenton e 480 min para os demais processos. O processo Fenton não reduziu de forma significativa os compostos orgânicos do resíduo e por esta razão foi descontinuado em 300 min. No entanto, no período de 480 min, nenhum processo foi suficiente para remover 100 % dos contaminantes orgânicos da água de lavagem. O foto-Fenton apresentou o melhor desempenho reduzindo 93,8 % do COT. Embora apresente remoção satisfatória do COT, o processo foto-Fenton não é suficiente para enquadrar o efluente, dentro do tempo proposto, na norma para lançamento de efluentes para águas salobras ou águas salinas (CONAMA 430/2011), nem tampouco reduzir a toxicidade do efluente, que aumenta após o tratamento.
Biodiesel production process need some attention of the residue generation. The purification step generate a lot amount of biodiesel wastewater up in a 1:3 biodiesel: wastewater proportion. Considering the current growth in biodiesel production and, consequently, the wastewater volume, the treatment of this residue is important to prevent that it get in a water bodies in raw form. Due his low cost and high organic compounds degradation rates, the advanced oxidation processes Fenton and photo-Fenton are good alternatives for the treatment of biodiesel wastewater and that is the reason why they were used in this work. Biodiesel wastewater samples were obtained in a laboratory scale and characterized by TOC (40700 ± 204 mg L-1), Oil & Grease (2237 ± 204 mg L-1), COD (24210 ± 265 mg L-1) and LC50 (0,118 % in pH 7) for the FET. The best concentration from Fe(II) and H2O2 were evaluated to Fenton process, that used FeSO4⋅7H2O as iron source to obtain a [Fe2+] = 20 mg L-1 and 250 μL of H2O2 30 % v/v add each 15 min in 100 mL of sample under constant stirring, due his performance and low environmental impact. Photo-Fenton process was carried out using same concentrations of Fenton but inside a homemade reactor under irradiation of a 125W mercury mid-pressure lamp without bulb. To evaluate the light and the peroxide influence, the processes UV and UV/H2O2 were carried out too. Samples were collected periodically until 300 min for Fenton and 480 min for the other processes for TOC measures. Fenton did not reduce significantly the organic compounds and for that reason was stopped in 300 min. However, no one reduce 100 % of organic contaminants of the biodiesel wastewater. The photo-Fenton showed the best performance and reduced approximately 93.2 % of COT, but was not enough to put the residue accord legislation (CONAMA 430/2011) and nor reduced the toxicity of effluent.
APA, Harvard, Vancouver, ISO, and other styles
14

Silva, Janaina Andréa. "Análise da viabilidade de implantação de um sistema de captação de água de chuva para lavagem de aeronaves e reuso de efluentes." Universidade Estadual Paulista (UNESP), 2018. http://hdl.handle.net/11449/152917.

Full text
Abstract:
Submitted by JANAINA ANDRÉA DA SILVA null (janaina.silva@embraer.com.br) on 2018-03-07T17:10:23Z No. of bitstreams: 1 Microsoft Word Viewer - DISSERTAÇÃO VERSÃO FINAL 06 MARÇO 2018.pdf: 1343678 bytes, checksum: 41cf1e1bcf5b5b653a5b3ea1b1a8e9fd (MD5)
Approved for entry into archive by Pamella Benevides Gonçalves null (pamella@feg.unesp.br) on 2018-03-07T17:46:16Z (GMT) No. of bitstreams: 1 silva_ja_me_guara.pdf: 1343678 bytes, checksum: 41cf1e1bcf5b5b653a5b3ea1b1a8e9fd (MD5)
Made available in DSpace on 2018-03-07T17:46:16Z (GMT). No. of bitstreams: 1 silva_ja_me_guara.pdf: 1343678 bytes, checksum: 41cf1e1bcf5b5b653a5b3ea1b1a8e9fd (MD5) Previous issue date: 2018-01-29
O objetivo deste trabalho foi analisar a viabilidade de implantação de um sistema de captação de água de chuva para abastecer o processo de lavagem de aeronaves na EMBRAER, e este estudo pode ser estendido para aplicação aos centros de manutenção de companhias aéreas nacionais e aeroportos. O trabalho consiste em um estudo de caso. Em sua realização foram analisadas as condições locais para implantar o sistema de coleta de água de chuva, a quantidade de recurso pluvial disponível na região de São José dos Campos, a necessidade de armazenagem de água para suprir períodos de estiagem, a qualidade necessária da água para atender a esta finalidade, e as aplicações para o reuso do efluente da lavagem de aeronaves. Os resultados mostraram que o volume de água de chuva disponível na região é suficiente para abastecer o processo de lavagem das aeronaves e que a água tem qualidade suficiente para esta aplicação. O trabalho mostra ainda que com a reutilização do efluente gerado na lavagem de aeronaves torna a implantação do projeto viável e que além do retorno financeiro, a proposta traz benefício ambiental, preservando o recurso hídrico de boa qualidade.
The aim of this work was to verify the feasibility of introduce a rainwater harvesting system to supply the aircraft washing process at EMBRAER and this study may be extended to the airlines maintenance centers and airports. This work consists in a case study. To perform this work were studied the local conditions to introduce the rainwater harvesting system, the amount of rainfall available in São José dos Campos, the need to storage water to supply drought periods, the quality of the water to supply the process with security and the applications for reuse the effluent from aircraft washing process. The results showed that the amount of rainwater avaiable in the region is enough to supply the aircrafts washing process and the water is sufficient in quality for this application. The work also showed that the reuse of the effluent generated by the aircraft washing process makes feasible the project implementation. In addition to the financial return, the purpose brings environmental benefits preserving the good quality water resources.
APA, Harvard, Vancouver, ISO, and other styles
15

Zimmermann, Valmir Elemar. "Desenvolvimento de tecnologia alternativa para tratamento de efluentes visando a reutilização da água de postos de lavagem de veículos." Universidade Estadual do Oeste do Parana, 2008. http://tede.unioeste.br:8080/tede/handle/tede/1872.

Full text
Abstract:
Made available in DSpace on 2017-07-10T18:08:09Z (GMT). No. of bitstreams: 1 Arquivo de texto 1.pdf: 2186590 bytes, checksum: 8cfe993c740c2908a563e68a70f3ec3d (MD5) Previous issue date: 2008-02-15
The increasing concern with the environment and specially with the use of the water resources resulted in the increasing valorization of the drinking water as well of consumption. Innumerable are the activities that use this resource, one of them, the Car Wash Station (CWS), object of this research. In Brazil, about 32,700 CWS approximately consume 3.7 millions of cubical meters of water per month that transform it in wastewater. In this context, this work had, as general objective, the development of alternative technology for wastewater treatment aiming the recovery of the water from car wash station. For so much, the methodology had as base seven main aspects: 1) diagnosis of the current situation around the activity of CWS; 2) characterization of the crude wastewater generated by CWS; 3) mathematical modeling to identify the critical factors of project; 4) development of the prototype; 5) researches of patents to verify the innovation; 6) elaboration of the process for patent request and 7) specifications of the criteria for development of installation and operation manuals of the wastewater treatment system. In the case of Toledo/PR city, from the 47,155 registered self-driven vehicles (of the whichonly 27% pass for CWS), with a medium consumption of 2682,5 m3 water per month, it was verified a generation of 2.921,14 m3 wastewater per month with highly variable characteristic, having only 97% of the CWS some treatment system. The inefficiency of the conventional systems was verified and the analysis resulted in the proposition/development of two technologies (patent request number MU8701195-6 23/07/2007 and number MU8701196-4 23/07/2007) having, among their characteristics, the low cost,installation/operation/maintenance easiness, need of little space, efficiency and versatile in application form. In this way, this work should intended to contribute with the minimization of the environmental problem around the activity of CWS
A crescente preocupação com o meio ambiente e, em especial com o uso dos recursos hídricos resultou na valorização crescente da água potável como bem de consumo. Inúmeras são as atividades que utilizam este recurso, uma delas, os Postos de Lavagem de Veículos (PLV s), objeto da pesquisa. No Brasil, cerca de 32.700 postos de lavagem transformam aproximadamente 3,7 milhões de metros cúbicos de água/mês em efluente. Neste contexto, este trabalho teve como objetivo geral o desenvolvimento de tecnologia alternativa para tratamento de efluentes visando a reutilização da água de postos de lavagem de veículos. Para tanto, a metodologia teve como base sete aspectos principais: 1) Diagnóstico da situação atual em torno da atividade dos PLV s; 2) Caracterização do efluente bruto gerado pelos PLV s; 3) Modelagem matemática para identificar os fatores críticos de projeto; 4) Desenvolvimento do protótipo; 5) Pesquisa em banco de patentes para verificar a inovação; 6) Elaboração do processo para pedido de patente e 7) Especificações dos critérios para desenvolvimento de manuais de instalação e operação do sistema de tratamento de efluentes de PLV s. Para o caso da cidade de Toledo-PR constatou-se a existência de 47.155 veículos automotores cadastrados (dos quais apenas 27% passam pelos PLVs), com um consumo médio de 2682,5 m3 de água/mês, geração de 2.921,14 m3 de efluente/mês com característica altamente variável, tendo apenas 97% dos postos algum sistema de tratamento. Constatou-se a ineficiência dos sistemas convencionais cuja análise resultou na proposição/desenvolvimento de duas tecnologias (pedido de patente N° MU8701195-6 de 23.07.2007 e Nº MU8701196-4 de 23.07.2007) tendo entre suas características o baixo custo, facilidade de instalação/operação/manutenção, necessidade de pouco espaço físico, eficiente e versátil na sua forma de aplicação. Desta forma, este trabalho deve contribuir com a minimização da problemática ambiental em torno da atividade dos PLV s.
APA, Harvard, Vancouver, ISO, and other styles
16

Reis, Jose Roberto Bezerra dos. "Estudo de reuso e reciclagem de agua de lavagem de filtro rapido de estação de tratamento de agua, em sistema de ciclo fechado, independente." [s.n.], 2009. http://repositorio.unicamp.br/jspui/handle/REPOSIP/258655.

Full text
Abstract:
Orientador: Ruben Bresaola Junior
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo
Made available in DSpace on 2018-08-14T17:21:03Z (GMT). No. of bitstreams: 1 Reis_JoseRobertoBezerrados_M.pdf: 4806731 bytes, checksum: f4634921271dbf74dd3233925df387a5 (MD5) Previous issue date: 2009
Resumo: O projeto foi desenvolvido visando estudar o tratamento e o reuso da água de lavagem de filtro para reciclagem nesta função, dentro de um circuito fechado, em sistema independente das atividades de produção de uma estação de tratamento de água de abastecimento. O sistema foi dotado de unidade de mistura de polímero, pré-filtro de pedregulho e filtro de dupla camada (F3), semelhante aos usados na estação de tratamento de água. O pré-filtro foi retirado do sistema porque não forneceu a eficiência esperada. Com esta disposição foi monitorado o número de vezes que a água obtida poderia ser reutilizada sem influir na qualidade da água de início de filtração do filtro piloto F1, o que mostrou ser maior ou igual cinco vezes. A perda da água de lavagem no sistema foi de 0,13%, bastante significativo perante os valores costumeiros de 2 a 5%. O sistema operou sempre com partículas floculentas, nunca com partículas coloidais.
Abstract: The project was developed with the aim of studying the treatment and the reuse of rapid filter backwash water for recycling in this role, within a closed cycle, under system independent of production activities of a water treatment plant. The system was assembled with a polymer blending unit, a gravel preliminary upflow filter and a dual layer filter(F3), similar to those used in the water treatment plant. The pre-filter was withdrawn because it did not provided the expected efficiency. With this provision, it was monitored the number of times that water obtained could be reused without affecting the quality of water filtration top of the filter F1 which proved to be greater or equal to five times. The loss of filter backwash water in the system was 0,13%, quite significant when compared to the usual 2 to 5%. The system always worked with flocculent particles, not with colloidal particles.
Mestrado
Saneamento e Ambiente
Mestre em Engenharia Civil
APA, Harvard, Vancouver, ISO, and other styles
17

Teixeira, Priscila da Cunha. "Emprego da flotação por ar dissolvido no tratamento de efluentes de lavagem de veiculos visando a reciclagem da agua." [s.n.], 2003. http://repositorio.unicamp.br/jspui/handle/REPOSIP/258243.

Full text
Abstract:
Orientador: Carlos Gomes da Nave Mendes
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil
Made available in DSpace on 2018-08-03T21:52:05Z (GMT). No. of bitstreams: 1 Teixeira_PrisciladaCunha_M.pdf: 1387697 bytes, checksum: c784aacc4ff7aa84b5cf9a9541830d57 (MD5) Previous issue date: 2003
Mestrado
APA, Harvard, Vancouver, ISO, and other styles
18

Rocha, Dayane Cristina da. "Pré-tratamento biológico da água residuária de lavagem do biodiesel de óleo de soja por micro-organismos produtores de lipase." Universidade Estadual do Oeste do Parana, 2010. http://tede.unioeste.br:8080/tede/handle/tede/341.

Full text
Abstract:
Made available in DSpace on 2017-05-12T14:48:09Z (GMT). No. of bitstreams: 1 Dayane Cristina da Rocha.pdf: 1452913 bytes, checksum: 15c01c66c71278c9a56f1e0eb396f63c (MD5) Previous issue date: 2010-07-05
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
Biodiesel is a derived fuel from renewable biomass that can substitute partially or totally the fossil fuel. The production process of the biodiesel is composed by the following stages: raw material preparation, transesterification reaction, phases separation, alcohol recovery and dehydration, glycerin destillation and purification of the renewable fuel, resulting in glycerin as a by-product and purification wastewater. The formed wastewater during the stage of purification presents high concentration of oils and greases, presenting potential to contaminate bodies of water. One of the treatment proposals of this residue is the enzymatic hydrolysis use by lipases for removal of oils and greases. Due the specificity of lipases and its large technological application, it appears that it is necessary to search new microorganisms producers of this enzyme, with specific characteristics to the residue in study. Therefore, its objective was to evaluate the biodegradation of the biodiesel washing(purification) water, gotten trough transesterification between soy oil and methanol, by means of production of lipase, using isolated microorganisms from the proper residue. For both, analyses of the initial physicist-chemistries characteristics had been made with the residuary water of the biodiesel washing, then it had been isolated and chosen, by means of determinations of the lipase activity. Following, it was made a test of fat biodegradation, fixing the variables pH (5,95), temperature (35ºC), rotation (180 rpm) and nitrogen concentration (3 g.L-1) and establishing as variable the two microorganism preselected and the time (24, 48, 72, 96 and 120 h). At the time (48 h) and Klebsiella oxytoca microorganism defined, the optimization process of the fat removal in the treatment of the wastewater was initialized. For such, it was used a designed central composite (DCCR), establishing as independent variables pH and nitrogen concentration, the other variable ones had been previously fixed in: temperature 35ºC, rotation 180 rpm and 48 hours. For experimental validation of the model considered for fat removal it was carried through, in triplicate copy, a biodegradation test in the excellent established conditions. These results, on the other hand, had been compared to a kinetics one carried through the same conditions, but using as inoculun the commercial product Hábil FTW SF. The biodiesel purification wastewater had presented high potential of environmental impact, presenting a concentration of O&G of 6,76 g.L-1. From the six isolated microbiological cultures in the decantation tank of this effluent one, two microorganisms (A and B) had been selected presenting one high potential of lipase production, with enzymatic index of 0,56 and 0,57, respectively. Trough DCCR ways it has been concluded that the best point to the maximum efficiency of removal of O&G from the residuary water of biodiesel purification was equivalents to pH 7,5 and 4,00 g.L-1 of nitrogen, resulting in an efficiency of 60% in the removal of fat. The treatment of the wastewater using the proper isolated microorganism from the effluent (Klebsiella oxytoca) was not differentiated from the carried through essays using the commercial product Hábil FTW SF.
O biodiesel é um combustível derivado de biomassa renovável que pode substituir, parcial ou totalmente, o combustível de origem fóssil. O processo de produção de biodiesel é composto das seguintes etapas: preparação da matéria-prima, reação de transesterificação, separação de fases, recuperação e desidratação do álcool, destilação da glicerina e purificação desse combustível renovável, tendo como subproduto a glicerina e como resíduo água de purificação. A água residuária, formada durante a etapa de purificação, apresenta alto teor de óleos e graxas, tendo potencial para contaminar corpos água. Uma das propostas de tratamento deste resíduo é a utilização de hidrólise enzimática por lipases para remoção de óleos e graxas. Devido à especificidade das lipases e sua ampla aplicação tecnológica, verifica-se que é necessário pesquisar novas cepas de micro-organismos produtores desta enzima, com características específicas do resíduo em estudo. Deste modo, teve-se por objetivo neste estudo avaliar a biodegradação da água de lavagem (purificação) do biodiesel, obtido por transesterificação entre óleo de soja e metanol, por meio de produção de lipase, utilizando micro-organismos isolados do próprio resíduo. Para tanto, foram feitas análises das características físico-químicas iniciais da água residuária da lavagem do biodiesel e a partir desse resíduo foram isolados e selecionados micro-organismos com potencial de produção de lipase. Em seguida, foi feito um ensaio de biodegradação de gordura, fixando-se as variáveis: pH (5,95), temperatura (35ºC), rotação (180 rpm) e concentração de nitrogênio (3 g.L-1) e tendo como variáveis os micro-organismos pré-selecionados e o tempo (24, 48, 72, 96 e 120 h). Com o tempo (48h) e o micro-organismo Klebsilla oxytoca, iniciou-se o processo de otimização da remoção de gordura no tratamento da água residuária. Para tal, utilizou-se um Delineamento Composto Central Rotacional (DCCR), tendo como variáveis independentes pH e concentração de nitrogênio; as demais variáveis foram previamente fixadas em: temperatura 35ºC, rotação 180 rpm e tempo 48 h. Para validação experimental do modelo proposto para remoção de gordura foi realizado, em triplicata, um ensaio de biodegradação nas condições ótimas estabelecidas. Estes resultados, por sua vez, foram comparados com uma cinética realizada nas mesmas condições, mas utilizando como inóculo o produto comercial Hábil FTW SF. A água residuária de purificação do biodiesel apresentou alto potencial de impacto ambiental, tendo uma concentração de O&G de 6,76 g.L-1. Das seis culturas microbianas isoladas do tanque decantação deste efluente, dois micro-organismos (A e B) foram selecionados, apresentando um alto potencial de produção de lipase, com índice enzimático de 0,56 e 0,57, respectivamente. Por meio do DCCR, conclui-se que o ponto ótimo para máxima eficiência de remoção de O&G da água residuária de purificação do biodiesel foi equivalente ao pH 7,5 e 4,00 g.L-1 de nitrogênio, obtendo-se uma eficiência de 60% na remoção de gordura. O tratamento da água residuária utilizando o micro-organismo isolado Klebsilla oxytoca, a partir do próprio efluente, não se diferenciou dos ensaios realizados utilizando o produto comercial Hábil FTW SF.
APA, Harvard, Vancouver, ISO, and other styles
19

Chaves, Karina Oliveira. "Desenvolvimento e aplicação de sistema de floco-flotação por ar dissolvido para tratamento da água de lavagem do filtro da ETA Gavião." reponame:Repositório Institucional da UFC, 2012. http://www.repositorio.ufc.br/handle/riufc/3801.

Full text
Abstract:
CHAVES, K. O. Desenvolvimento e aplicação de sistema de floco-flotação por ar dissolvido para tratamento da água de lavagem do filtro da ETA Gavião. 2012. 125 f. Dissertação (Mestrado em Engenharia Civil) - Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2012.
Submitted by Marlene Sousa (mmarlene@ufc.br) on 2012-09-13T17:27:18Z No. of bitstreams: 1 2012_dis_kochaves.pdf: 3780564 bytes, checksum: c01f7a9b02759238448368189535643a (MD5)
Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2012-09-25T14:04:58Z (GMT) No. of bitstreams: 1 2012_dis_kochaves.pdf: 3780564 bytes, checksum: c01f7a9b02759238448368189535643a (MD5)
Made available in DSpace on 2012-09-25T14:04:58Z (GMT). No. of bitstreams: 1 2012_dis_kochaves.pdf: 3780564 bytes, checksum: c01f7a9b02759238448368189535643a (MD5) Previous issue date: 2012
In Brazil the filter backwash wastewater is normally released in to the water resources without proper treatment, representing a potential danger to the environment. Thus, it is necessary to treat this wastewater in order to dispose it in accordance to federal and state environmental laws. Studies show that Dissolved Air Flotation (DAF) technology has been feasible for this purpose. It is believed that the incorporation of flocculation in curtains and air dissolved flotation system in the same unit can promote high efficiency and significant size reduction, which translates in a technological innovation: the Floculator - Dissolved Air Flotation (FFAD) unit. A FFAD pilot unit was built to evaluate the treatment of Gavião Water Treatment Plant filter backwash wastewater, owned by the Water and Wastewater Company of Ceará (CAGECE). This research had as main objective to quantify and verify the compliance of the filter backwash wastewater parameters to the Resolution No. 430/11 and 357/05 of CONAMA and Ordinance No. 154/2002 of SEMACE. Treatability studies were performed with filter backwash wastewater using Jartest to evaluate the influence of cationic polymer dosages and the feasibility of decreasing flocculation velocity gradients (35 to 5.6 s-1) in the FFAD. Experimental runs of the flocculation - flotation system were performed to evaluate the best polymer dosage and the process parameters such as recirculation rates (TR) and surface application rates (TAS). These parameters were compared by observing the lower residual turbidity and best removal efficiency in the clarified water (AC). The treated wastewater was again characterized using physicalchemical and bacteriological parameters and compared to the specific legislation. The results showed that the use of 1 mg.L-1 of polymer, recirculation rate of 15% and surface application rate of 57 m3.m-2.d-1, presented the highest turbidity efficiency removal (> 98%) and a very stable performance against sudden changes in the influent quality (94.4 to 410UT). It should be noted that the unity showed also a high average efficiency total coliforms removal (98.5%), apparent color removal (97.6%), DOC removal (92.6%), of aluminum (84.1%) removal and turbidity (99.2 %) removal. Given these results, it was concluded that the AC coming from the treatment of ALF by ETA WTP Gavião FFAD met the discharge parameters listed for water resources.
No cenário brasileiro, os resíduos de Estações de Tratamento de Água (ETAs) são normalmente lançados in natura em corpos hídricos, apresentando-se como potencialmente danosos ao meio ambiente, sendo necessário tratá-los para que sejam descartados conforme os aspectos legais. Estudos demonstram que a tecnologia da Flotação por Ar Dissolvido (FAD) tem sido viável para este fim. Acredita-se que a incorporação da floculação em cortinas numa mesma unidade de flotação possa promover elevada eficácia ao sistema, traduzindo-se como uma inovação tecnológica: o Floco-Flotador por Ar Dissolvido (FFAD). Uma unidade piloto de FFAD foi construída para o tratamento da água de lavagem dos filtros da ETA Gavião, pertencente à Companhia de Água e Esgoto do Ceará (CAGECE). Esta pesquisa teve como objetivo quantificar e verificar o atendimento da água de lavagem dos filtros (ALF) desta ETA e da água clarificada via FFAD aos padrões de lançamento de efluentes conforme as Resoluções nº 430/11 e 357/05 do CONAMA e Portaria nº 154/2002 da SEMACE. Estudos de tratabilidade da ALF em Jartest foram realizados para avaliar a influência da dosagem de polímeros catiônicos e a viabilidade de gradientes de velocidade decrescente (35 a 5,6 s-1) a serem empregados no equipamento de FFAD desenvolvido. Ensaios de flotação foram realizados a fim de avaliar a dosagem do polímero e os parâmetros de processo como taxas de recirculação (TR) e taxas de aplicação superficial (TAS). Após definidos estes parâmetros, ensaios de FFAD foram realizados em triplicata para coleta da AC a fim de compará-la com os principais padrões de lançamento de efluente em corpos hídricos classe II. Somente os parâmetros pH, Fluoreto, Amônia, E. coli e Sólidos dissolvidos da ALF atenderam aos padrões de lançamento. Ao aplicar polímero a 1 mg.L-1, taxa de recirculação de 15%, gradientes de velocidade decrescente (19,3 a 5,6 s-1), taxa de aplicação superficial de 57 m3.m-2.d-1 com tempo de detenção hidráulico de 22 minutos no FFAD, os resultados alcançaram elevada eficiência na remoção de turbidez (superior a 98%) mesmo enfrentando variações bruscas na qualidade da ALF (94,4 a 410 UT). Observou-se também significativa eficiência média na remoção de coliformes totais (98,5%), cor aparente (97,6%), DQO (92,6%) e remoção de alumínio (84,1%). Diante destes resultados, constatou-se que a ALF da ETA Gavião tratada via Floco-flotação por ar dissolvido atendeu aos referidos padrões de lançamento em corpos hídricos.
APA, Harvard, Vancouver, ISO, and other styles
20

Lopes, Luís Filipe Gomes. "Estudos de hidrodinâmica e de qualidade ambiental da água : aplicação na definição do caudal ecológico num segmento do rio Lima." Master's thesis, Departamento de Engenharia Civil, 2001. http://hdl.handle.net/10316/15783.

Full text
APA, Harvard, Vancouver, ISO, and other styles
21

Lage, Epaminondas de Souza. "Aproveitamento de água pluvial em concessionárias de veículos na cidade de Belo Horizonte." reponame:Repositório Institucional da UFSC, 2012. http://repositorio.ufsc.br/xmlui/handle/123456789/94194.

Full text
Abstract:
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Civil, Florianópolis, 2010
Made available in DSpace on 2012-10-25T07:28:49Z (GMT). No. of bitstreams: 1 285079.pdf: 5965589 bytes, checksum: 76c9f10aa5788a1ef639d5402adc6cc5 (MD5)
O uso de águas pluviais é uma importante forma de otimizar os recursos hídricos e promover o desenvolvimento sustentável. O objetivo deste trabalho foi avaliar o potencial de economia de água potável, por meio do uso de água pluvial, para a lavagem de carros em concessionárias de veículos na cidade de Belo Horizonte. Obteve-se dados de precipitação de estações meteorológicas próximas, realizou-se o levantamento de áreas para coleta de águas pluvial, pesquisou-se o histórico do número de veículos lavados, assim como o consumo de água potável. A demanda de água pluvial foi considerada como uma percentagem do consumo de água potável utilizada para essa atividade. O estudo foi realizado utilizando-se o Netuno, um programa computacional para análise de volume de reservatório e percentagem de economia de água potável com uso de água pluvial. Para esse estudo foram realizadas simulações dos volumes dos reservatórios inferiores de cada concessionária em análise em intervalos de 10.000 litros e, em cada caso, obteve-se um volume ideal de reservatório inferior, e o correspondente percentual de economia de água potável. Adicionalmente, foram realizadas novas simulações, com aumentos dos volumes dos reservatórios inferiores de cada concessionária, até atingir o limite máximo do potencial de economia de água potável. A análise de viabilidade econômica foi realizada por meio do cálculo do valor presente líquido, do tempo de retorno dos investimentos e da taxa interna de retorno, tendo em conta o potencial de economia de água potável para um período de 15 anos de vida útil do projeto. Para calcular os índices financeiros utilizou-se a taxa média de atratividade igual à inflação calculada, a partir da média dos últimos quatro anos, fixada no valor de 0,36% ao mês. A principal conclusão obtida com este trabalho foi a de que, usando-se a água pluvial para a lavagem de veículos em concessionárias de veículos em Belo Horizonte, pode-se economizar entre 9,74% e 26,80% de água potável, com investimentos viáveis e atrativos. Para todos os casos analisados, obteve-se valor presente líquido positivo, tempo de retorno de investimento entre 75 e 143 meses, e taxas internas de retorno compreendidas entre 0,63% e 1,52% a.m.
The use of rainwater is an important way to optimize water resources and promote sustainable development. The aim of this study is to assess the potential for potable water savings by using rainwater for washing cars at car dealers in the city of Belo Horizonte. Rainfall data from weather stations nearby, roof areas available for collecting rainwater, average number of vehicles washed as well as the consumption of potable water were obtained. Demand for rainwater was considered a percentage of potable water consumption. The study was conducted using the Netuno, a computer software for analysis of rainwater tank capacity and percentage of potable water savings due to the use of rainwater. Volume simulations of the lower tanks in each studied car dealer have been held, considering 10,000 liters# intervals, and, in each case, were reached an optimum level of the lower tank, and the corresponding savings in the use of potable water. Additionally, further simulations have been undertaken, considering increases in the volume of the lower tanks for each car dealer, in order to reach the maximum potential for potable water savings. The investment feasibility analysis was performed by calculating the net present value, payback period and internal rate of return taking into account the potential for potable water savings for a period of 15 years - the project#s life span. So as to calculate the financial ratios, the average rate of attractiveness has equaled inflation, based on the average value for the past four years of 0.36% per month. The main conclusion of this work is that by using rainwater for car wash at car dealers in Belo Horizonte, one can save between 9.74% and 26.80% of potable water through totally viable and attractive investments. For all examined cases we have obtained positive net present value. The payback period ranged between 75 and 143 months, with internal rates of return varying between 0.63% and 1.52% per month.
APA, Harvard, Vancouver, ISO, and other styles
22

Malaguti, Vilmar dos Santos. "Reuso de água e resíduos gerados pela lavagem de caminhões betoneiras: análise do efeito na resistência à compressão de concreto usinado." Universidade Tecnológica Federal do Paraná, 2016. http://repositorio.utfpr.edu.br/jspui/handle/1/1886.

Full text
Abstract:
O objetivo deste trabalho é analisar a resistência à compressão do concreto e seus possíveis efeitos com o reuso da água e dos resíduos de lavagens dos caminhões betoneiras. A revisão bibliográfica sobre o assunto proposto foi estudado e discutido em países como Grécia, Taiwan, Alemanha, Itália, Cingapura e outros, o que serviu de apoio e reforço para este trabalho. O método para analisar a resistência à compressão foi de comparação entre uma amostra controle (traço padrão de 30 MPa) e amostras com diferentes composições. O resultado de cada amostra foi diferente em função de sua composição, no entanto, pode-se afirmar ganho econômico na ordem de 20,21 R$/m3, além da resistência à compressão ser maior que 90% da amostra controle. As análises realizadas nas amostras através de DRX, MEV e EDS comprovaram que não houve síntese de novos minerais, somente pequenas quantidades (menor do que os limites de detecção do método de DRX) de alumino-silicatos e quartzo dissolvidos que foram sintetizados em novos minerais cristalinos, que podem ser atribuídos como substancias amorfas em estado sol-gel. Com o resultado observa-se que o reuso da água de lavagem dos caminhões betoneiras não interferem na resistência à compressão de novos concretos, assim como o resíduo de lavagem que não apresentou nenhum elemento diferente do composto no cimento, também não interfere na resistência à compressão de novos concretos, desde que haja controle da água presente.
The objective of this study is to analyze the strength of concrete compression and its possible effects on water reuse and waste washes of concrete mixer trucks. The literature review on the proposed subject was studied and discussed in countries like Greece, Taiwan, Germany, Italy, Singapore and others, which served as support and reinforcement for this work. The method for analyzing the compressive strength was compared between the control sample (standard stroke 30 MPa) and samples with different compositions. The result of each sample was different depending on their composition, however, it can be stated economic gain on the order of 20,21 R$/m3, in addition to the compressive strength is greater than 90% of the control sample. The samples were analyzed by DRX, MEV and EDS showed that there was no synthesis of new mineral, only small amounts (lower than the detection limits of the DRX method) dissolved alumino-silicates and quartz which have been synthesized into new mineral crystalline, which can be assigned as amorphous substances in sol-gel state. With this result it was observed that the reuse of the concrete mixer trucks washing water does not interfere with the compressive strength of new concrete, as well as the washing residue which presented no different element of the compound in cement, does not interfere with the compressive strength new concrete, provided that control of the water present.
APA, Harvard, Vancouver, ISO, and other styles
23

Souza, Aline Ferreira de. "Otimização do uso de aditivo estabilizador de hidratação do cimento em água de lavagem dos caminhões-betoneira para produção de concreto." Florianópolis, SC, 2007. http://repositorio.ufsc.br/xmlui/handle/123456789/89612.

Full text
Abstract:
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-graduação em Engenharia Civil
Made available in DSpace on 2012-10-23T00:17:50Z (GMT). No. of bitstreams: 1 243737.pdf: 6797256 bytes, checksum: ee4e5e47f80cf7e4876093dd9c439ce5 (MD5)
APA, Harvard, Vancouver, ISO, and other styles
24

Scarazzato, Tatiana. "Tratamento de efluente contendo HEDP por eletrodiálise." Universidade de São Paulo, 2013. http://www.teses.usp.br/teses/disponiveis/3/3133/tde-11072014-102330/.

Full text
Abstract:
Em processos de eletrodeposição, substâncias à base de cianeto são empregadas como complexantes e portadores do metal a ser depositado. Entretanto, a toxicidade associada ao cianeto e a evolução das legislações ambiental e trabalhista impulsionaram a exploração de matérias-primas alternativas aos sais cianídricos. Um estudo desenvolvido no Instituto de Pesquisas Tecnológicas avaliou a modificação de um banho comercial isento de cianeto para processos de deposição de cobre em substratos de Zamac. Neste estudo, foi utilizado um banho à base do ácido 1,hidroxietano-1,1- difosfônico, ou HEDP, um composto orgânico capaz de formar complexos estáveis com íons metálicos. Para viabilizar a substituição do cianeto pelo HEDP, deve-se consolidar uma metodologia para o tratamento do efluente gerado nas operações que o envolvam. A técnica de eletrodiálise surge como uma alternativa considerada limpa, que dispensa mudanças de fase e adição de produtos químicos ao processo. O método consiste na utilização de membranas íon-seletivas para promover a separação de espécies iônicas entre soluções utilizando a diferença de potencial elétrico entre dois pólos como força motriz. Neste trabalho, avaliou-se a aplicação da eletrodiálise no tratamento de um efluente galvânico à base de HEDP. Foram utilizadas soluções sintéticas simulando as águas de lavagem de um banho toque composto por complexos de cobre e HEDP. A construção das curvas de polarização permitiu a determinação da densidade de corrente limite a ser empregada na eletrodiálise. Nos ensaios de eletrodiálise, foi avaliada a extração percentual dos íons de cobre e de HEDP das soluções sintéticas. As membranas utilizadas também foram analisadas para investigação de possíveis alterações estruturais. Os resultados mostraram extração de até 99,7% de cobre e 94,4% de HEDP, possibilitando o reaproveitamento das soluções tratadas nos tanques de lavagem e, simultaneamente, a reutilização dos íons extraídos, compensando perdas por arraste. As análises químicas comprovaram a presença de complexos aniônicos formados entre o cobre e o HEDP. A alteração na acidez do meio permite a separação deste complexo e a recuperação de cobre e de HEDP em compartimentos separados. As análises realizadas por MEV/EDS mostraram a presença de picos de cobre e fósforo nas superfícies das membranas. A avaliação feita por um processo de lixiviação indicou a ocorrência de depósitos nas superfícies das membranas. Os incrementos na acidez das soluções finais indicam recuperação do HEDP e as análises de foto-oxidação do ácido orgânico apontaram degradação inferior a 7% nos ensaios avaliados.
In electroplating processes, cyanide-based substances are used as complexing agents and as raw materials in form of metal salts. However, the toxicity associated with cyanide and the evolution of environmental and employment laws have been promoting research for the development of new raw materials in electroplating processes. A study conducted at the Institute for Technological Research evaluated the modification of commercial cyanide free bath for processes of copper coating on zinc alloys. In the performed study, a news alkaline copper bath was formulated using 1 hydroxyethane-1, 1 diphosphonic, or HEDP, an organic compound known for forming stable complexes with metal ions. To support the replacement of cyanide, it becomes necessary to consolidate a methodology for treatment of the wastewaters generated by operations involving HEDP. Electrodialysis is considered a clean technology which dispenses phase changes and the addition of chemicals to the treatment process. The method consists in the use of ion-selective membranes to promote the separation of ionic species from solutions, using as driving force the difference of electrical potential between two electrodes. In this study the application of electrodialysis in the treatment of electroplating wastewaters containing HEDP was evaluated. Synthetic solutions were prepared, simulating the rinsing water from a bath composed of copper and HEDP complexes. The construction of the current-voltage-curves allowed the determination of the limiting current density applied in the electrodialysis stack. During electrodialysis, the percentage of extraction of copper and HEDP from synthetic solutions were evaluated. The membranes used were analyzed to investigate possible structural changes. The results showed extracting rates up to 99,7% copper and 94,4% HEDP, allowing the reuse of solutions in rinse steps and simultaneously reuse of copper and HEDP ions to compensate drag-out losses. Chemical analysis confirmed the presence of anionic complexes formed between copper and HEDP. The decrease of pH allows the separation of these complexes and the recovery of copper and HEDP in separate compartments. The results of SEM/EDS analysis of membranes showed the presence of peaks of copper and phosphorus. The analysis made by a leaching process showed the occurrence of deposits on the membranes surface. The increases in acidity of the final solutions indicate recovery of HEDP and the photooxidation analysis indicated degradation of the organic acid under 7% in evaluated samples.
APA, Harvard, Vancouver, ISO, and other styles
25

Cargnin, Miria Trentin. "ANÁLISE DO PROCESSO DE LAVAGEM E DESINFEÇÃO DE ROUPAS HOSPITALARES: O CASO DA LAVANDERIA DO HUSM." Universidade Federal de Santa Maria, 2008. http://repositorio.ufsm.br/handle/1/8056.

Full text
Abstract:
Water is the most important element of the nature, fundamental to all existent life. The possibility of its breakdown has influence upon the urgent necessity of its preservation. Human beings, in their individual existential selfishness, are still indifferent in relation to nature signals of possible damages. It is for sure that socio-economical activities need this resource to develop them, and then they need to know how to use it rationally. In this way, this study aims at studying the washing and disinfection process of hospital clothes in order to minimize water consumption besides proposing improvements at HUSM s laundry, considering the descriptive diagnose carried out in this place from October/2007 to February/ 2008. The methodology used was exploratory descriptive quantitative and qualitative, with a case study technique. The data collection was done through applied questionnaires, forms, inspection log books that were answered by respondents who work in this sector and compose this study sample. Aiming at the validation and confirmation of the provided information, photographic registrations, archives and documents checking, besides observations in the workplace studied were carried out. The collected and analyzed data pointed to improvement possibilities in the washing and disinfection process of hospital clothes and to washing type standardization, resulting in a 21,9% of water volume and products use reduction, increasing the clothes quality. Besides that, this study has contributed to reduce effluent liquids with chemical charges production, pointed out existent deficiencies in the laundry and corrected them and presented the possibility of total types of washing automation, proportioning advantages to internal and external costumers, to the institution and also to the environment.
A água é o elemento mais importante da natureza, fundamental a toda a vida existente. A possibilidade de seu esgotamento repercute na necessidade urgente de sua preservação. O homem em seu egoísmo individual existencial permanece ainda indiferente aos sinais de perigo manifestados pela natureza. É certo que as atividades econômico-sociais necessitam desse recurso para se desenvolverem, por isso precisam saber utilizá-lo racionalmente. Considerando isso este estudo teve como objetivo estudar o processo de lavagem e desinfecção de roupas hospitalares visando à minimização do consumo de água e proposições de melhorias na lavanderia do HUSM, a partir de diagnóstico descritivo realizado na lavanderia nos meses de outubro/2007 a fevereiro/2008. A metodologia utilizada foi do tipo exploratória descritiva quanti-qualitativa, com técnica de estudo de caso. A coleta dos dados se deu mediante aplicação de questionários, formulários, roteiros de inspeção, os quais foram respondidos pelos colaboradores que atuam nesse setor compondo a amostra desse estudo. Visando a confirmação e validação das informações fornecidas, foram realizados registros fotográficos, observações no ambiente estudado, consultas a documentos e arquivos informatizados. Os dados coletados e analisados demonstraram possibilidades de melhorias no processo de lavagem e desinfecção de roupas hospitalares e padronização dos tipos de lavagens, repercutindo em significativa redução do volume de água consumido em 21,9% e de produtos, aumentando a qualidade da roupa. Além disso, esse estudo contribuiu para redução na produção de efluentes líquidos com carga química, apontar deficiências existentes na lavanderia e corrigi-las, apresentar a possibilidade de automação total dos tipos de lavagem; proporcionando vantagens aos clientes externos e internos, à instituição e ao meio ambiente.
APA, Harvard, Vancouver, ISO, and other styles
26

Araujo, Ana Paula Cosso Silva. "Tratamento de efluentes de lavagem de ônibus e de lavanderia por flotação por ar dissolvido e filtração visando o reúso de água." Universidade Tecnológica Federal do Paraná, 2017. http://repositorio.utfpr.edu.br/jspui/handle/1/2258.

Full text
Abstract:
Capes
A cadeia de transporte de ônibus intermunicipal e interestadual necessita de serviços associados à lavagem veicular e a lavanderia, para a lavagem de capas de poltronas e cobertores. Desta forma, este segmento demanda um elevado consumo de água, aliado a utilização de produtos químicos que podem comprometer a qualidade dos recursos hídricos. O reúso de água é uma técnica que visa reduzir o consumo de água potável para fins que não necessitem de tal qualidade. As empresas de transporte de ônibus podem implantar o sistema de reúso nas unidades de lavagem de ônibus. Entretanto, deve-se realizar um tratamento adequado do efluente para que a qualidade de água produzida não cause impacto negativo nas atividades da unidade onde está sendo reutilizada, bem como à saúde dos operadores. Assim, este trabalho teve como objetivo promover o tratamento de efluentes provenientes de uma empresa de transporte de ônibus rodoviário localizado na cidade de Londrina, Paraná. Os efluentes empregados neste trabalho são gerados nos setores de lavagem de ônibus e lavanderia, ambas atividades realizadas na empresa. Os sistemas de tratabilidade foram avaliados em escala de bancada, sendo estes: A) sistema de coagulação/floculação/FAD; B) coagulação/floculação/FAD seguido de pós-tratamento por filtração em meio granular sob pressão; C) coagulação/floculação/filtração em meio granular sob pressão e D) filtração direta em meio granular sob pressão, utilizando os coagulantes AQUAFLOC/LS e AQUA-PAC, visando o reúso do efluente tratado na lavagem dos ônibus. O delineamento estatístico aplicado aos ensaios de coagulação/floculação/FAD foi o Delineamento Composto Central Rotacional (DCCR). As variáveis independentes aplicadas foram: concentração do coagulante AQUAFLOC/LS, concentração do coagulante AQUA-PAC, concentração do polímero e pH de coagulação. As condições de coagulação/floculação aplicadas para os ensaios de FAD foram: Gmr 800 s-1, G1ml 90 s-1, G2ml 50 s-1 e G3ml 30 s-1, correspondendo aos tempos de rotação de 1; 10; 5 e 5 minutos, respectivamente. A Pressão na câmara de saturação foi de 6 bar, A Taxa de recirculação utilizada de 20% e as taxas de aplicação superficial foram 35, 70, 120 e 150 m3 m-2 dia-1. Para os ensaios de coagulação/floculação/filtração as condições de coagulação/floculação foram: Gmr 800 s-1 e G1ml 50 s-1. Para os ensaios de filtração, foi confeccionado um filtro de meio granular sob pressão em escala de bancada contendo como material filtrante areia e cascalho. Os sistemas de tratabilidade foram avaliados com relação à remoção de matéria orgânica, sólidos, nitrogênio, fósforo e surfactantes. Por meio da aplicação do método do DCCR determinou-se uma faixa ótima de atuação dos coagulantes no tratamento dos efluentes. Ao se promover a mistura dos efluentes de ambos os setores para posterior tratamento, a faixa ótima de concentração do coagulante AQUAFLOC/LS foi de 220 a 260 mg L-1 com pH de coagulação natural, enquanto que as faixas consideradas ótimas de concentração do AQUA-PAC estão entre 50 a 200 mg Al2O3 L-1 com pH de coagulação de 6,00 a 7,50 e entre 200 a 320 mg Al2O3 L-1 com pH de coagulação de 8,30 a 9,00. Para o tratamento do efluente da lavagem dos ônibus, a concentração ótima de AQUAFLOC/LS está entre 55 e 110 mg L-1 com pH de coagulação de 6,00 a 7,20, a concentração do AQUA-PAC variou entre 65 a 85 mg Al2O3 L-1 com pH de coagulação natural. Por fim, para o tratamento do efluente da lavanderia a faixa ótima de concentração do AQUAFLOC/LS variou entre 200 e 400 mg L-1 com pH de coagulação de 8,90 a 9,00, e para o AQUA-PAC a faixa ótima de concentração variou de 600 a 700 mg Al2O3 L-1 com pH de coagulação de 7,20 a 7,60. Ao se avaliar os diferentes sistemas de tratabilidade, verificou-se que os sistemas de coagulação/floculação/FAD seguido de filtração e coagulação/floculação/filtração empregando o coagulante AQUAFLOC/LS apresentaram os maiores índices de redução dos parâmetros analisados com eficiências de redução de DQO variando entre 73% a 81%, de turbidez entre 93% a 94%, de sólidos suspensos de 16% a 100% e de surfactante de 90% a 98%. O sistema de filtração em meio granular sob pressão possibilitou a obtenção de efluentes tratados passíveis de serem reutilizados em serviços de lavagem de ônibus.
The intercity and interstate bus transportation chain requires services associated with car wash and laundry, for the washing of armchairs covers and blankets. Thus, this segment demands high consumption of water, combined to the use of chemicals that can compromise the quality of water resources. Water reuse is a technique that aims to reduce the consumption of drinking water for purposes that do not require such quality. Bus companies can deploy a reuse system in their bus wash units. However, adequate effluent treatment must be carried out so that the quality of the water produced does not negatively impact the activities of the unit where it is being reused, as well as the operators’ health. Therefore, this work aimed to promote the effluents treatment from a bus transportation company located in the city of Londrina, Paraná. The effluents used in this work are generated in the bus washing and laundry sectors, both activities carried out in the company. The treatability systems were evaluated on bench scale, being these: A) coagulation/flocculation/DAF system; B) coagulation/flocculation/DAF followed by post-treatment by granular filter media filtration under pressure; C) coagulation/flocculation/granular filter media filtration under pressure and D) granular filter media direct filtration under pressure, using the AQUAFLOC / LS and AQUA-PAC coagulants, aiming at the reuse of the treated effluent on the buses wash. The statistical design applied to the coagulation/flocculation/DAF assays was the Central Rotational Composite Design (CRCD). The independent variables applied were: AQUAFLOC/LS coagulant concentration, AQUA-PAC coagulant concentration, polymer concentration and pH coagulation. The coagulation/flocculation conditions applied for the DAF assays were: Gmr 800 s-1, G1ml 90 s-1, G2ml 50 s-1 and G3ml 30 s-1, corresponding to the rotation times of 1; 10; 5 and 5 minutes, respectively. The pressure in the saturation chamber was 6 bar, the recirculation rate used was 20% and the rates of surface application were 35, 70, 120 and 150 m3 m-2 day-1. For the coagulation/flocculation/filtration tests, the coagulation/flocculation conditions were: Gmr 800 s-1 and G1ml 50 s-1. For the filtration tests, a bench scale granular filter under pressure was prepared containing sand and gravel filter material. The treatability systems were evaluated in relation to the organic matter removal, solids, nitrogen, phosphorus and surfactants. Through the application of the CCDR method, an optimum range of coagulant action in the effluent treatment was determined. By promoting the mixing of the effluents from both sectors for subsequent treatment, the optimum concentration range of the AQUAFLOC/LS coagulant varied from 220 to 260 mg L-1 with a natural coagulation pH, while the optimum concentration range of AQUA- PAC are between 50 and 200 mg Al2O3 L-1 with coagulation pH from 6.00 to 7.50 and between 200 and 320 mg Al2O L-1 with coagulation pH from 8.30 to 9.00. For the treatment of bus washing effluent, the optimum AQUAFLOC/LS concentration varied between 55 and 110 mg L-1 with coagulation pH from 6.00 to 7.20, the AQUA-PAC concentration ranged from 65 to 85 mg Al2O3 L-1 with natural coagulation pH. Finally, for the laundry effluent treatment, the optimum AQUAFLOC/LS concentration range varied from 200 to 400 mg L-1 with a coagulation pH from 8.90 to 9.00, and for AQUA-PAC, the optimum range concentration varied from 600 to 700 mg Al2O3 L-1 with 11 coagulation pH from 7.2 to 7.6.When evaluating the different treatability systems, it was verified that the coagulation/flocculation/DAF systems followed by filtration and coagulation/flocculation/filtration using the AQUAFLOC/LS coagulant presented the highest reduction indices of the analyzed parameters with reduction efficiencies of COD ranging from 73% to 81%, turbidity between 93% and 94%, suspended solids from 16% to 100% and surfactant from 90% to 98%.The granular filter media filtration system under pressure made it possible to obtain treated effluents that could be reused in bus washing services.
APA, Harvard, Vancouver, ISO, and other styles
27

Faria, Priscila Andrade Silva. "Efeitos no solo e nas plantas de cafeeiro conilon decorrentes da fertirrigação com água residuária da lavagem e despolpa de seus frutos." Universidade Federal do Espírito Santo, 2008. http://repositorio.ufes.br/handle/10/6608.

Full text
Abstract:
Made available in DSpace on 2016-12-23T14:37:38Z (GMT). No. of bitstreams: 1 Priscila Andrade Silva Faria.pdf: 1130176 bytes, checksum: 52e846b30ca2fe276ef258f90d0265bc (MD5) Previous issue date: 2008-05-21
This work was developed in the experimental area of the Núcleo de Estudos de Difusão de Tecnologia em Floresta, Recursos Hídricos e Agricultura Sustentável (NEDTEC), located in the municipal district of Jerônimo Monteiro, ES, with plants in the phase of initial development, and in the Escola Agrotécnica Federal de Alegre (EAFA), located in the district of Rive, in the municipal district of Alegre, ES, with plants in production phase. The objective of this work was to evaluate the effects current of the fertigation with wastewater from washing and pulping of the conilon coffee cherries on the chemical attributes of the soil, development and mineral nutrition of the coffee plant conilon. The wastewater from washing and pulping of the conilon coffee cherries (ARC) were obtained in the Fazenda Experimental de Marilândia of property of the Instituto Capixaba de Pesquisa, Assistência Técnica e Extensão Rural (INCAPER), characterized in the Laboratório de Análise de Fertilizantes, Águas, Minérios, Resíduos Sólidos e Plantas (LAFARSOL) and applied in doses estimated in function of the storage capacity of water in the soil. In NEDTEC, the experiment was developed in split-plots arrangement (7 x 5), having in the plots seven doses of ARC (0, 19, 38, 57 and 76 mm, applied in a single time, represented by witness, D11, D21, D31 and D41, respectively; 38 mm, parceled in two applications, represented by D22; and 57 mm, parceled in three applications, represented by D33) and the subplots constituted by the five evaluation epoch (30, 60, 90, 120 and 150 days after application of the wastewater), mounted in a completely randomized design, with three repetitions. In EAFA, the experiment was developed in split-plots arrangement (6 x 2 x 5), having in the plots a factorial scheme (6 x 2) with six doses of ARC (0, 62 and 93 mm applied in a single time, represented by witness (T), D11 and D21, respectively; 62 mm, parceled in two applications, represented by D22; and 93 mm, parceled in three applications, represented by D33) and two depths (0 - 0,20 and 0,20 - 0,40 m) and the subplots constituted by the five evaluation epoch (30, 60, 90, 120 and 150 days after application of the wastewater), mounted in randomized blocks design, with three repetitions. The data obtained in both experiments were submitted to the variance analysis in level of 5% by test F. When significant for the qualitative factor, they were compared by the test of Tukey to 5% and, for the qualitative factor, it was maderegression and the models were chosen with base in the significance of the coefficients regression, using the test t of Student, being adopted the level of 5% of probability and also by the largest determination coefficient (r2). The analyses were accomplished using the software SAEG 8.0 and the graphs made in Excel. Analyzing the results, concluded that the wastewater of the coffee can be used in the fertigation, as final destiny, since that applied in doses according with the water stock capacity in the soil, as proposed in this work
Este trabalho foi desenvolvido na área experimental do Núcleo de Estudos de Difusão de Tecnologia em Floresta, Recursos Hídricos e Agricultura Sustentável (NEDTEC), localizado no município de Jerônimo Monteiro, ES, com plantas na fase de desenvolvimento inicial, e na Escola Agrotécnica Federal de Alegre (EAFA), localizada no distrito de Rive, no município de Alegre, ES, com plantas em fase de produção. O objetivo deste trabalho foi avaliar os efeitos decorrentes da fertirrigação com água residuária da lavagem e despolpa dos frutos de cafeeiro sobre os atributos químicos do solo, desenvolvimento e nutrição mineral do cafeeiro conilon. A água residuária proveniente da lavagem e despolpa do cafeeiro conilon (ARC) foi obtida na Fazenda Experimental de Marilândia de propriedade do Instituto Capixaba de Pesquisa, Assistência Técnica e Extensão Rural (INCAPER), caracterizada no Laboratório de Análise de Fertilizantes, Águas, Minérios, Resíduos Sólidos e Plantas (LAFARSOL) e aplicadas em doses estimadas em função da capacidade de armazenamento de água no solo. No NEDTEC, o experimento foi desenvolvido em esquema de parcelas subdivididas (7 x 5), tendo nas parcelas sete doses de ARC (0, 19, 38, 57 e 76 mm, aplicadas em uma única vez, representadas por testemunha (T), D11, D21, D31 e D41, respectivamente; 38 mm, parcelada em duas aplicações, representadas por D22; e 57 mm, parcelada em três aplicações, representadas por D33) e as subparcelas constituídas pelas cinco épocas de avaliação (30, 60, 90, 120 e 150 dias após aplicação da água residuária), montado em delineamento inteiramente casualizado, com três repetições. Na EAFA, o experimento foi desenvolvido em esquema de parcelas subdivididas (6 x 2 x 5), tendo nas parcelas um esquema fatorial (6 x 2) com seis doses de ARC (0, 62 e 93 mm, aplicadas em uma única vez, representadas por Testemunha, D11 e D21, respectivamente; 62 mm, parcelada em duas aplicações, representadas por D22; e 93 mm, parcelada em três aplicações, representadas por D33) e duas profundidades (0 0,20 e 0,20 0,40 m) e as subparcelas constituídas pelas cinco épocas de avaliação (30, 60, 90, 120 e 150 dias após aplicação da água residuária), montado em delineamento em blocos casualizado, com três repetições. Os dados obtidos em ambos os experimentos foram submetidos à análise de variância em nível de 5% pelo teste F.Quando significativo para o fator qualitativo, foram comparados pelo teste de Tukeya 5% e, para o fator qualitativo, foi feito regressão e os modelos foram escolhidos com base na significância dos coeficientes de regressão, utilizando o teste t de Student, adotando-se o nível de 5% de probabilidade e também pelo maior coeficiente de determinação (R2). As análises foram realizadas utilizando-se o software SAEG 8.0 e os gráficos confeccionados no Excel. Analisando os resultados obtidos, conclui-se que a água residuária do café pode ser utilizada na fertirrigação, como destino final, desde que seja aplicada em doses segundo a capacidade de armazenamento de água no solo, como proposto neste trabalho
APA, Harvard, Vancouver, ISO, and other styles
28

Machado, Bianca Coelho. "Potabilização de água com elevada densidade de cianobactérias e microalgas através de sistema de dupla filtração em meio granular utilizando filtro de lavagem contínua." Florianópolis, SC, 2011. http://repositorio.ufsc.br/xmlui/handle/123456789/94712.

Full text
Abstract:
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Ambiental
Made available in DSpace on 2012-10-25T14:53:10Z (GMT). No. of bitstreams: 1 300032.pdf: 7255310 bytes, checksum: 3fdb72df5b4d497ac024915b78316edb (MD5)
No mundo, muitos mananciais de abastecimento apresentam água com qualidade inferior ao padrão estabelecido para consumo humano; situação preocupante, visto que muitas doenças podem ser transmitidas tanto pelo consumo quanto pelo contato com água contaminada. Dentre as enfermidades, pode-se citar a intoxicação da população pelo consumo de água contaminada por cianotoxinas, o que, em alguns casos, pode ser fatal. Várias são as técnicas para potabilização de água com elevada densidade de cianobactérias e microalgas; porém a filtração direta não pode ser citada como exemplo. O motivo dessa não utilização se dá pelo fato de, para esse tipo de água, haver uma rápida colmatação do filtro, além da possibilidade de transpasse de células e toxinas. Entretanto, fazendo-se uso de um processo de lavagem contínua, tal tecnologia apresenta-se como promissora. Na filtração direta, destaca-se a filtração ascendente, na qual a água escoa no sentido dos grãos mais grossos para os mais finos e emprega-se um único material filtrante (areia). A pesquisa em questão utilizou a dupla filtração: filtro de lavagem contínua e filtro ascendente para potabilização de água, objetivando, principalmente, a remoção de cianobactérias e microalgas. Três tipos de tratamento foram testados: Tratamento 1 # adição de coagulante na entrada do filtro de lavagem contínua; Tratamento 2 # adição de coagulante na entrada de ambos os filtros; e Tratamento 3 # adição de coagulante apenas na entrada do filtro ascendente; além disso, comparam-se, três taxas de filtração, 150, 200 e 250 m³.(m².d)-1, para o filtro ascendente. Os parâmetros avaliados foram: turbidez, cor aparente, cor verdadeira, carbono orgânico dissolvido (COD), absorbância 254 nm, pH, condutividade, sólidos dissolvidos totais (SDT), clorofila a, densidade de cianobactérias, concentração de saxitoxina, perda de carga e tempo de filtração. O sistema de dupla filtração estudado se mostrou eficiente para a remoção de cianobactérias e microalgas, em alguns casos a remoção foi de cerca de 96%, e vantajoso quanto aos serviços operacionais, tendo em vista que diminui as lavagens do segundo filtro, permitindo obter carreira de filtração de até 338 h e um grande aumento na produção efetiva de água. O emprego desse sistema de tratamento não provocou a lise celular e observou-se redução na concentração de cianotoxinas, tendo em vista que houve remoção de células de cianobactérias.
Worldwide, there is a significant amount of water source with quality below the standard for human use. Clearly, it is a worrying situation because too many diseases can be transmitted by contaminated water. Among the diseases, we ought to cite the intoxication of the population by consumption of water contaminated with cyanotoxins, which in some cases might be fatal. There are diversified techniques for treatment of water with high density of cyanbacteria and microalgae. However, direct filtration can not be considered one example. The reason is that, under such conditions, occurs a quick blinding of the filter. Furthermore, cells and toxins might run through. Surprisingly enough, using the continuous backwashing process, a promising technology reveals itself.The direct filtration, which is based on rising filtration, demands only one filtering material (sand) that flows water from coarse grains to the finest.Double filtering system was used: continuous backwashing filter and rising filter for water treatment. The main purpose was the removal of cyanobacteria and microalgae. Three different types of water treatment were tested: Treatment 1 # Coagulant addition at the intake of the continuous backwashing filter; Treatment 2 # Coagulant addition in both filters inlet; Treatment 3 # Coagulant addition at the intake of the upflow filter. Furthermore, a comparision of three filtration rates was made: 150; 200; 250 m³.(m².d)-1 for the upflow filter.The parameters evaluated were: turbidity, apparent color, true color, dissolved organic carbon (DOC), absorbance at 254nm, pH, conductivity, total dissolved solids (TDS), chlorophyll a, density of cyanobacteria, the concentration of saxitoxin, loss of load and filtering duration.In terms of operational services, the system has shown some advantages. For example, reducing the washes of the second filter, which permit a filtration run up to 338 hours. Consequently, the double filtering system achieves a large increment in effective water production. Moreover, this system did not cause cell lysis and we observed a reduction in concentration of cyanotoxins; facts that foster relevance, considering that there was cyanobacteria removal.
APA, Harvard, Vancouver, ISO, and other styles
29

Canale, Ivan 1977. "Caracterização microbiológica, parasitológica e físico-química da água de lavagem de filtros recirculada em ETA de ciclo completo = Microbiological, parasitological and physico-chemical characterization of filter backwash water recirculated in full cycle WTP." [s.n.], 2014. http://repositorio.unicamp.br/jspui/handle/REPOSIP/267710.

Full text
Abstract:
Orientador: Cassiana Maria Reganhan-Coneglian
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Tecnologia
Made available in DSpace on 2018-08-26T04:53:56Z (GMT). No. of bitstreams: 1 Canale_Ivan_M.pdf: 7288933 bytes, checksum: 93678fbce9055e79b05000fd1cab8c23 (MD5) Previous issue date: 2014
Resumo: Estações de Tratamento de Água (ETA) de ciclo completo. Como o volume de ALF pode representar de 3 a 6% do volume de água tratada produzido na ETA, existe interesse cada vez maior no tratamento desse efluente para fins de recirculação junto com a água bruta aduzida à ETA. Entretanto, existe uma preocupação de que essa água residuária possa conter matéria orgânica, sólidos totais, metais, carbono orgânico, precursores de trihalometanos, cistos/oocistos de protozoários ou outras impurezas concentradas durante o processo de filtração. Este trabalho de pesquisa tem como objetivo caracterizar com base em parâmetros físico-químicos, microbiológicos e parasitológicos a água de lavagem de filtros gerada e recirculada na ETA Capim Fino, em Piracicaba / SP - Brasil. Foram avaliadas 12 amostras da água bruta do manancial que abastece a ETA (rio Corumbataí), ALF bruta, ALF clarificada (com o uso de polímeros auxiliares ou por simples sedimentação) e água filtrada da ETA. Para caracterização da ALF foram analisados os parâmetros físico-químicos: cloro residual, cor, turbidez, pH, alumínio solúvel, sólidos totais fixos, sólidos totais voláteis, sólidos sedimentáveis, carbono orgânico total e o potencial de formação de trihalometanos; os parâmetros microbiológicos: coliformes totais, Escherichia coli; e os protozoários patogênicos: Giardia spp. e Cryptosporidium spp. O monitoramento da ALF bruta apontou como principais características físico-químicas deste efluente elevados teores de turbidez, alumínio, carbono orgânico total, sólidos totais (fixos e voláteis), sólidos sedimentáveis e potencial de formação de THM. A clarificação da ALF com polímero aniônico possibilitou a redução na concentração dos diversos constituintes analisados. Giardia spp. foi detectada na água bruta (cinco resultados positivos e concentração de cistos variando de Abstract: Filter backwash water (FBWW) is the largest liquid waste generated in a conventional water treatment plant (WTP). As the volume of FBWW can represent from 3 to 6% of the volume of treated water produced in the WTP, there is an increasing interest in treatment and recycling of this effluent with raw water adducted to WTP. But FBWW would contain concentrated organic matter, total solids, metals, organic carbon, trihalomethanes (THM) precursors, cysts/oocysts of protozoa and other impurities which could be a concern. This research aims to characterize FBWW generated and recirculated in Capim Fino WTP in Piracicaba / SP - Brazil by physico-chemical, microbiological and parasitological analyses. Twelve samples of raw water from the river that supplies the WTP (Corumbataí river), raw FBWW, clarified FBWW (using auxiliary polymers or simple sedimentation) and filtered water were collected and evaluated. The physico-chemical parameters were: residual chlorine, color, turbidity, pH, soluble aluminum, total fixed and volatile solids, settleable solids, total organic carbon and THM potential formation; microbiological parameters: total coliforms and Escherichia coli; and pathogenic protozoa Giardia spp. and Cryptosporidium spp. Monitoring the raw FBWW pointed as the main physicochemical characteristics high levels of turbidity, aluminum, total organic carbon, total solids (fixed and volatile), sedimentary solids and THM potential formation. Clarification of FBWW with anionic polymer resulted in a reduction in the concentration of the various parameters. Giardia spp. was found in raw water (five positive results and cyst concentration ranging from Mestrado
Tecnologia e Inovação
Mestre em Tecnologia
APA, Harvard, Vancouver, ISO, and other styles
30

Wiebeck, Hélio. "Obtenção e caracterização, em laboratório, do carvão ativo de bagaço de cana, visando sua utilização no tratamento de água de lavagem de cana-de-açúcar." Universidade de São Paulo, 1987. http://www.teses.usp.br/teses/disponiveis/3/3137/tde-25072017-082448/.

Full text
Abstract:
As amostras de carvão ativo de bagaço de cana-de-açúcar foram preparadas em temperaturas de carbonização de 500, 600 e 700 ºC, com tempos de ativação de 60 e 120 minutos e concentração de agente ativante (ZnC12) 30 e 60% em relação ao bagaço seco original. Foi utilizado como padrão, para verificação de eficiência, um carvão ativo alemão (Riedel). Estas amostras foram caracterizadas pelas seguintes análises: rendimento; teor e umidade; teor de cinzas; pH; teor de substâncias solúveis em água. Foi também estudado o desempenho destas amostras no descoramento de água de lavagem de cana-de-açúcar, utilizando 1% e 1,5% em peso de carvão ativo. Amostras preparadas a 500 ºC, 60 minutos e concentração de agente ativamente 0%, 30% e 60% em relação ao peso de bagaço seco original foram utilizadas no tratamento de água de lavagem de cana-de açúcar visando a diminuição do potencial poluidor, essas mesmas amostras foram utilizadas para determinação de poder de adsorção, equação e isoterma de Freundlich. Os resultados mostraram ser viável, em escala de laboratório a obtenção de carvão ativo de bagaço de cana-de-açúcar, para utilização no tratamento de água de lavagem de cana-de-açúcar visando diminuir o seu potencial poluidor.
Samples of activated carbon from cane-thrash were prepared in carbonization temperatures of 500, 600 and 700 ºC; activation times of 60 and 120 minutes, and concentrations of activating agent (ZnC12) 30 and 60% in relation to the original dry bagasse. A German activated carbon, was used a standard (Riedel). The samples were characterized by the following analysis: yield, proportion (5) of humidity, proportion of ashes; pH; proportion of solubles in water substances. It was also studied the performance in discolouring sugar-cane washing water using 1% and 1,5% in weight of activated carbon. Samples prepared in 500 ºC, 60 minutes and activating agent concentration of 0%, 30% and 60% in relation to the weight of the original dry bagasse were used in the treatment of sugar-cane washing water the purpose of reducing the polluter potential. They were used to determine the adsorption power, equation and Freundlish isotherm. The results showed it is possible to obtain active carbon from cane-thrash in laboratory scale, to be used in the treatment of sugar-cane washing water with the purpose of reducing its polluter potential.
APA, Harvard, Vancouver, ISO, and other styles
31

Fontana, Antonio Osmar. "Sistema de leito de drenagem e sedimentador como solução para redução de volume de lodo de decantadores e reuso de água de lavagem de filtros." Universidade Federal de São Carlos, 2004. https://repositorio.ufscar.br/handle/ufscar/4357.

Full text
Abstract:
Made available in DSpace on 2016-06-02T20:00:51Z (GMT). No. of bitstreams: 1 DissAOF.pdf: 6243442 bytes, checksum: ee1b36639019670cbb0ec3ede6df6bcd (MD5) Previous issue date: 2004-02-27
Water supply systems utilize, in most cases, conventional Water Treatment Plants (WTPs). These plants use alum and ferric salts in their coagulation process, and produce residues (sludge) mainly in filter systems and decanter tanks. The produced residues may be toxic to man and are usually disposed of on environment without any kind of treatment, therefore causing pollution. They present fluid characteristic with low solid content and great amount of water. Such characteristic hampers its transportation and proper disposal. The Cardoso plant used to fit the profile of pollutant, dumping its untreated sludge directly into a nearby stream. As a solution to this problem a system with a drainage bed for the sludge from decanter tank and a sedimentation tank for the backwash water from filters have been built. The system was built within the plant area itself. The drainage bed consists of a brick tank with a gravel layer support coated with a geotextile. The solid mass from the dewatered sludge showed adequate conditions as far as characteristics necessary for its final transportation and proper disposal. The water drained from sludge (effluent) is sent to the sedimentation tank. The turbidity, solids and COD were greatly reduced. The system was designed for a less than 30 days utilization period. The sedimentation tank consists of a fiberglass vase installed in a position that allows it to also receive the effluent from the drainage bed. The clarified water is recirculated to the influent of the water treatment plant and the solids are pumped to the drainage bed together the sludge from decanter tank. The system s operation does not require much labor and equipment. The aim of the research carried out was to design and analyze the drainage bed behavior according to prototype developed in the PROSAB 2 research Tema IV, integrated with Sedimentation Tank. Such integrated technology is an effective solution for the great majority of Water Treatment Plants with available areas. It is recommended that such system (Drainage bed and Sedimentation Tank) to be implemented should be always arranged to properly each individual Water Treatment Plant. Further studies should be also made on alternative of throwing clarified water straight from decanter tank to filters before dumping the sludge into drainage bed.
Os sistemas de abastecimento utilizam, na maioria, as Estações de Tratamento de Água (ETAs) convencionais. Essas estações utilizam em seu processo de coagulação sais de ferro ou de alumínio e produzem resíduos (lodos), principalmente, nos decantadores e filtros. Os resíduos produzidos podem ser tóxicos ao homem e normalmente são dispostos sem nenhum tipo de tratamento no meio ambiente causando poluição. Apresentam característica fluida com baixos teores de sólidos e grande quantidade de água. Essa característica dificulta seu manejo para transporte e disposição adequada. A ETA Cardoso, se enquadrava no perfil de poluidora lançando seus resíduos sem tratamento diretamente no corpo d água existente nas proximidades. Como solução para este problema foi implantado um sistema constituído de Leito de Drenagem para os lodos de decantadores e Sedimentador para as águas de lavagem de filtros. O sistema foi construído na própria área da ETA. O Leito de drenagem é constituído de um tanque em alvenaria e meio drenante com camada suporte de brita recoberto com manta geotextil. A massa final de sólido do lodo desaguado apresentou condição suficiente para manejo de retirada, transporte e disposição. O drenado foi encaminhado ao Sedimentador para reuso. Apresentou grande redução de turbidez, sólidos e DQO. O sistema foi projetado para um período de utilização inferior a 30 dias. O Sedimentador é constituído de um tanque em fibra de vidro instalado em posição que possa receber também o drenado do leito de drenagem. A água clarificada do Sedimentador e o drenado do Leito de Drenagem são recirculadas para o início da ETA. Os sólidos sedimentados no Sedimentador são bombeados para o Leito de Drenagem juntamente com o lodo de decantador. A operação do sistema demanda pouca mão de obra e equipamentos. A pesquisa realizada teve como objetivo projetar e analisar o comportamento do Leito de Drenagem, de acordo com o protótipo desenvolvido na pesquisa do PROSAB 2 Tema IV, integrado com o Sedimentador. Essa tecnologia integrada se apresenta como solução efetiva para a grande maioria de ETAs com disponibilidade de área. É recomendado que sempre seja implantado o sistema (Leito de Drenagem e Sedimentador) em arranjos convenientes para cada ETA. A redução da área do Leito de Drenagem é função de estudos para lançamento da água clarificada dos decantadores diretamente para os filtros.
APA, Harvard, Vancouver, ISO, and other styles
32

Zaneti, Rafael Newton. "Desenvolvimento e validação da técnica integrada de Floculação-Flotação em Coluna (FFC), filtração em areia e cloração na reciclagem de água na lavagem de veículos." reponame:Biblioteca Digital de Teses e Dissertações da UFRGS, 2012. http://hdl.handle.net/10183/147616.

Full text
Abstract:
Técnicas e tecnologias poupadoras de água tem sido objeto de pesquisa no mundo inteiro, principalmente em modalidades urbanas. A presente tese de doutorado contribuiu para o desenvolvimento de um processo inovador descentralizado de reúso de água em ambientes comerciais, tomando como modelo a lavagem de veículos. A reciclagem de água na lavagem de veículos é uma prática que começa a ser intensamente empregada em países do primeiro mundo motivada por exigências legais. No Brasil, somente nas principais cidades, estima-se em 7 milhões de m³ o consumo mensal de água nesta atividade, aproximadamente 0,5% da demanda urbana por água. Mais, o efluente da atividade lavagem de veículos é ainda altamente poluído com surfactantes, nanopartículas e microorganismos, entre outros poluentes. Estes dados justificam o desenvolvimento de uma tecnologia que possibilite a reciclagem adequada de água nesta atividade, com viabilidade técnica e econômica. O presente trabalho desenvolveu, avaliou, validou e transferiu ao setor produtivo um processo baseado na aplicação integrada das técnicas de Floculação-Flotação em Coluna – FFC, filtração em areia e cloração para tratamento e reciclo destes efluentes. As unidades de floculação (floculador hidráulico em linha – tr = 10s, G > 1000s-1; Tanfloc SL - 200-700 mg.L-1) e geração de microbolhas (bombas centrifugas multifásicas – microbolhas com D32 = 75μm) possibilitaram a formação de flocos aerados (0,8–1,6 mm de diâmetro e velocidade de ascensão de 45-150m.h-1) e consequente alta taxa de separação sólido-líquido na coluna de flotação (>18m.h-1). A partir destes dados de caracterização da técnica, um sistema de reciclagem de água na lavagem de veículos de passeio foi instalado e monitorado ao longo de seis meses. Ainda, a técnica FFC foi empregada de forma integrada com a filtração em areia e a cloração (0,5 mgCl2.L-1). A água residuária e a água tratada via FFC+filtro de areia+cloração foram caracterizadas e a eficiência de remoção de sólidos suspensos (>85%), turbidez (>90%), surfactantes MBAS (>40%), DBO5 (>60%), DQO (>60%) coliformes totais (95%) e E.coli (99% - 2 log) determinada. Este estudo longo foi realizado em um lava-rápido comercial em Porto Alegre-RS e uma economia de 70% de água no processo de lavagem foi atingida. Entretanto, embora mais de 2000 carros tenham sido eficientemente lavados com a água tratada, foi observada uma tendência de aumento de sais dissolvidos, além de uma alta concentração de coliformes, mesma na água tratada. Assim, a quantificação de risco microbiológico (à saúde humana) e de risco químico (agressividade aos veículos e equipamentos – incrustações, manchas e corrosão) fez-se necessária. As metodologias aplicadas foram: o quantitative microbial risk assessment – QMRA e o balanço de massas de parâmetros de interesse. O QMRA mostrou ser necessário se limitar a concentração de E.coli a 200 NMP.100mL-1. Esta contagem de microrganismos foi atingida com dosagem mínima de 15 mgCl2.L-1. O balanço de massa proposto mostrou que a água de reúso, após cloração para efetivo controle microbiológico, apresenta concentração de sais e, especificamente, cloretos, em níveis aceitáveis. Quanto à viabilidade econômica, esta ficou confirmada por uma avaliação econômica simplificada que confrontou economia na despesa com água, versus custos de investimento e operação da tecnologia – a depender da demanda por água, o payback pode ser inferior a 6 meses. O pedido de patente da técnica foi depositado em 2008 e publicado na revista do INPI em 03/2010, sob o número PI 0802871-0, sendo a UFRGS a proprietária da técnica. A transferência da técnica à sociedade, por sua vez, foi realizada por diversas publicações em revistas e congressos nacionais e internacionais, bem como pela comercialização da tecnologia, revertendo benefícios à universidade e ao meio ambiente. A efetiva transformação da técnica em tecnologia, na nossa sociedade, somente irá ocorrer caso seja gerado um nicho inicial de mercado que sustente a continua aplicação e desenvolvimento da prática de reciclagem de água na lavagem de veículos. Para tanto, uma moderna legislação especifica deve ser criada e fiscalizada, bem como incentivos financeiros deverão ser estabelecidos. Espera-se que os resultados aqui apresentados sejam um indutor de ambos os processos.
Water savings technologies have been a research object around the world, mainly in urban modalities. The present PhD thesis contributes to this theme developing and validating an innovative decentralized water reuse technique in vehicles wash activity. The practice of water recycling/reuse in vehicles wash begins to be intensively employed in developing countries, where laws impose it. In Brazil, this practice is not imposed, but a monthly consumption of 7 millions of m³ (0.5 % of the total urban water demand) and a great pollution load justified such a practice, moreover when new technical and economically feasible techniques are domestically available. Herein, the developed, evaluated, and validated technique is based on the integration of flocculation-column flotation (FCF), followed by sand filtration and chlorination. The claimed advances of the proposed process are: in-line fast and turbulent flocculation/mixing – 10 s and 1,000 s-1, using a tannin based coagulant/flocculant; multiphase centrifugal pump microbubbles generation – generating bubbles with Sauter mean diameter (D32) around 75 μm; appearance of aerated flocs - 0,8 – 1,6 mm equivalent diameter with a rising rate in between 45 – 150 m.h-1; and fast solidliquid column flotation (high hydraulic-load – around 18 m.h-1). Following the successful development of the technique, a full scale water recycling system was installed and monitored in a commercial car wash per six month. The car wash wastewater and the treated water (FCF plus sand filtration and chlorination – 0,5 mgCl2.L-1) where characterized and the efficiency in removing suspended solids (> 85%), turbidity (> 90%), surfactant MBAS (> 40%), DBO5 (> 60%), total coliformes (95%) and E.coli (99%) determined. Regarding water consumption, a water audit showed 70% water save – average for 2,000 car washes. Observed drawbacks where the tendency for rising dissolved solids concentration and a still high concentration of E.coli in treated water. To better understand and control this drawbacks a mass balance and a quantitative microbiological risk assessment (QMRA) where employed. The answers where: i. Although there is a dissolved solid increment, the risk of vehicles and wash equipment corrosion and scaling are low, or controlled; ii. The microbiological risk of the water reclamation system can be controlled by limiting the E.coli counting in 200 CFU.100mL-1. Once the technical issue is solved, it works to walk trough economics. A simple economic evaluation was performed for different Brazilian state capitals and showed financial viability – depending on water demand and price the payback period can be as low as 6 months. Considering the potential for innovation, the process had it intellectual property (patent) required, being the University - UFRGS the proponent. By now, the technique is being transferred to the market by a great number of national and international publications. Moreover, a small company (an university spin-off) is commercializing the technique. Nevertheless, it seems that an early market must be constructed from public policies, supporting the commercialization and demonstration of the technique. It is well known that public policies, including at least financial incentives and technical regulation, are imperative to turn a technique in a technology (innovation chain). The authors believe that the present work will help in this evolution.
APA, Harvard, Vancouver, ISO, and other styles
33

Silva, Erton Gomes da. "Efeito da redução da vazão de água no chuveiro de lavagem final sobre a contaminação superficial de carcaças de frango após o pré-resfriamento em chiller." reponame:Repositório Institucional da UFPR, 2017. http://hdl.handle.net/1884/49579.

Full text
Abstract:
Orientador : Prof. Dr. Luciano dos Santos Bersot
Dissertação (mestrado) - Universidade Federal do Paraná, Setor de Palotina, Programa de Pós-Graduação em Ciência Animal. Defesa: Palotina, 30/05/2017
Inclui referências : f. 56-61
Resumo: Estabelecimentos de abate de aves utilizam grandes volumes de água para o abate e processamento de carcaças de frangos. Uma dessas etapas é a lavagem final das carcaças com água pressurizada. Etapa que ocorre após a evisceração. Para atender a legislação vigente são usados no mínimo 1,5 litros de água por carcaça abatida diariamente, a fim de remover a contaminação superficial. Essa lavagem demanda volume significativo de água ao se considerar o consumo total de um abatedouro em um dia de trabalho. A partir destas constatações, o objetivo deste estudo foi avaliar a possível redução do volume de água a ser utilizado neste ponto da linha de abate, bem como comparar a contaminação microbiana das carcaças antes e após a lavagem e também após o pré-resfriamento das carcaças por imersão em chillers. As coletas de amostras foram realizadas em um abatedouro de aves de grande porte, em três pontos diferentes da linha de abate, antes e após a lavagem das carcaças e após o chiller. Foram realizadas analises de contagens para os grupos de micro-organismos indicadores de higiene mais comumente utilizados: aeróbios mesófilos, enterobactérias, coliformes cotais e Escherichia coli. Neste estudo, a influência do estágio de lavagem sobre a contaminação superficial das carcaças de frango é mostrada em relação a quantidade de água utilizada. Nos resultados obtidos pode-se observar que a redução da contagem Log UFC/cm2 não foi significativamente diferente entre volume preconizado pela legislação (1,5 L) em relação a redução do volume para 1/3 (1L). Bem como as contagens realizadas após o chiller, para os três tratamentos avaliados (0L, 1L, 1,5L) também não demostraram diferença significativa das contagens realizadas antes da lavagem. A quantidade de água usada para lavagem influenciou coliformes totais e Escherichia coli. Não afetou aeróbios mesófilos e enterobactérias, nas contagens antes e após a lavagem. Assim, é possível rever o volume de água preconizado atualmente, reduzindo a captação de água, formação de efluentes e despejo em rios e, consequentemente custos, fazendo melhor uso da água e mantendo a qualidade microbiológica das carcaças. Palavras-chave: Consumo de água. Lavagem de carcaças de frango. Micro-organismos indicadores. Qualidade microbiológica.
Abstract: In poultry slaughterhouse establishments use large volumes of water to the slaughter and processing of chicken carcasses. One of those stages is the final washing of carcasses with pressurized water. Stage the is after the gutting. To comply current legislation are used at least 1.5 litres of water per carcass slaughtered daily, in order to remove the surface contamination. The washing stage demand a significant amount of water when considering the total consumption of a slaughterhouse in a day's work. From these observation, the aim of this study was to evaluate the possible reduction of the amount of water to be used at this in the slaughter line, as well as compare the microbial contamination of carcasses before and after washing and also after pre-cooling of the carcasses by immersion in chiller. The samples were collected at a large poultry slaughterhouse in three different points of the slaughter line, before and after the washing of carcasses and after the chiller. Analyses were undertaken of counts for the groups of microorganisms most commonly used hygiene indicators: mesophilic aerobic, Enterobacteriaceae, total coliform and Escherichia coli. In this study, the influence of the wash stage on the surface contamination of carcasses of chicken is shown in relation to the amount of water used. The results obtained can be noted that reducing the count Log CFU/cm2 was not significantly different between volume recommended by legislation (1.5 L) regarding the reduction of the volume to 1/3 (1L). As well as the counts carried out after the chiller for the three evaluated treatments (0 L, 1 L, 1.5L) is also not demonstrated significant difference of the counts carried out before washing. The amount of water used for washing influenced total coliforms and E. coli. Aerobic mesophilic and Enterobacteriaceae did not affect, in the counts before and after washing. Thus, it is possible to review the currently recommended water flow, reducing the water capture, training and dumping effluents into rivers and consequently costs, making better use of water and maintaining the microbiological quality of the carcasses. Key-words: Water consumption. Washing of chicken broilers. Indicators Microorganisms. Microbiological quality.
APA, Harvard, Vancouver, ISO, and other styles
34

Fialho, Ricardina Guerreiro. "Análise de rebaixamentos associados a pólos de captação de águas subterrâneas para abastecimento público - Pólo de captação de água da Apostiça." Master's thesis, Universidade de Évora, 2010. http://hdl.handle.net/10174/14669.

Full text
Abstract:
O Sistema Aquífero da Bacia do Tejo Sado/Margem Esquerda (T3) é uma das massas de água subterrânea mais importantes de Portugal Continental. Deste Sistema Aquífero depende o abastecimento público de cerca de 1.100.000 habitantes. Com base nos relatórios de captação de água dos treze furos verticais do pólo de captação da Apostiça, que constitui origem de água de um dos sistema de abastecimento da Câmara Municipal de Sesimbra, efectuou-se a caracterização hidrogeológica da massa de água, na zona em estudo, bem como das estruturas de captação. Utilizando os logs das captações efectuou-se um corte hidrogeológico na zona do pólo de captação, contribuindo para a definição do modelo conceptual do sistema aquífero naquela zona. Assim, as formações com interesse hidrogeológico são a alternância de areias e argilas, com espessuras entre 50 e 99 m e a alternância de grés, grés calcário e grés margoso, com 291 m de espessura máxima. Considera-se que as areias atingem maiores espessuras à medida que se caminha para Este, com um máximo na captação Ses10, sendo a passagem das formações arenosas para as calcárias directa ou mediante aquitardo de pequena espessura, com o máximo de 14 m. Adicionalmente foi aplicado o modelo de Theis aos rebaixamentos observados durante os ensaios de caudal, à data de construção, tendo-se obtido valores de transmissividade que variam entre 45 e 208 m2/dia. A partir das medições do nível da água efectuadas nas captações, sem extracção de água, procedeu-se a uma análise espacial da piezometria, para identificação do sentido de fluxo e do gradiente hidráulico. O sentido de fluxo é Este-Oeste e é coincidente com os referidos na bibliografia, ou seja em direcção ao rio Tejo e ao Oceano Atlântico. O gradiente é de um modo geral inferior a 1%, estando os maiores valores, tal como esperado, associados aos cones de rebaixamento das captações em que não foi possível recuperar os níveis. Com base na caracterização hidrogeológica anteriormente referida estudaram-se dois cenários de exploração para o pólo de captação de água da Apostiça: exploração actual e redimensionamento do pólo de captação (acréscimo de caudal por implantação de novas captações). Dos dois cenários de exploração constata-se que os rebaixamentos produzidos pelo caudal de exploração actual na generalidade são inferiores a 35,6 m. Os maiores rebaixamentos, tal como esperado, registam-se na zona próxima da captação a uma distância de cerca de 50 m, na direcção Este. Os rebaixamentos adicionais provocados pela expansão do pólo de captação, são da ordem dos 10 m nas captações Ses 13 e 12, de cerca de 5 m na captação Ses 11, de 3 m na captação Ses 10, de 2 m na captação Ses 8 e 9 e inferior a 1 m nas restantes captações. Verificou-se que o redimensionamento do pólo de captação não impede que sejam alcançados os objectivos ambientais especificados nos termos dos artigos 44º e 46º da Lei nº 58/2005, de 29 de Dezembro, dado que não são provocadas alterações na direcção do escoamento subterrâneo em consequência da variação de nível, nem intrusões de água salgada dada a proximidade do pólo de captação com a linha de Costa; ABSTRACT: The Tejo-Sado Aquifer System – left margin (T3) is one of the most important groundwater sources in Portugal. This Aquifer System is the main source of water supply to 1,100,000 people. The Sesimbra Municipality is one of the public supply managers whose water sources are located in this groundwater system. Based on the logs of thirteen wells of the Apostiça water supply system, a highly relevant system to the Sesimbra Municipality,a hydrogeological characterization was made of the aquifer in this area, including the hydraulic conditions in each of the wells. The lithological well logs were used to define the a hydrogeological cross-section of the site, contributing to the definition of the conceptual model of the aquifer system in the study area. The formations with hydrogeological interest are composed of alternating sands and clays, with thicknesses between 50 and 99 m and the intercalated layers of sandstone, calcareous sandstone, and thin sandstones, with 291 m of maximum thickness. The thicknesses of sands increase eastwards, with a maximum thickness in the well Ses10, being overlain by sands and limestones or by a thin aquitard layer with a maximum thickness of 14 m. The application of Theis model to piezometric levels measured during pumping tests, led to transmissivity values ranging between 45 and 208 m2/day. From water level measurements, made without water abstraction, it was possible to identify the direction of flow and its gradient. The main flow direction is East-West, i.e. towards the Tagus River and the Atlantic Ocean, and confirms published references,. The gradient is generally less than 1%, with and the highest values, as expected, being associated with drawdown cones in area where recovery was not complete. Based on the hydrogeological characterization mentioned above two scenarios of exploitation for the Apostiça area were studied: current exploitation and resizing of the well field (new wells). Of the two exploitation scenarios, was noted that the drawdown produced by current exploitation rates, generally are less than 35.6 m. The highest drawdowns are located near the wells in east direction. The expansion of the abstraction area cause na additional drawdown in the order of 10 m in Ses 13 and 12, about 5 m in Ses 11, 3 m in Ses 10, 2 m in Ses 8 and 9 and less than 1 m on the other wells. In was concluded the resizing of the exploited well field and abstracted volume does not prevent the environmental objectives specified under articles 44 and 46 of law 58/2005 of 29 December.
APA, Harvard, Vancouver, ISO, and other styles
35

Nunes, Francine Machado. "Produção e caracterização da cerâmica vermelha com a adição de resíduos oriundos da lavagem da lã de ovinos." Universidade Federal do Pampa, 2016. http://dspace.unipampa.edu.br:8080/xmlui/handle/riu/1262.

Full text
Abstract:
Submitted by Andrea Pereira (andrea.pereira@unipampa.edu.br) on 2017-03-13T18:17:27Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Dissertação de Mestrado_Francine Nunes_2016.pdf: 2824304 bytes, checksum: aa5a2fd56f57a8f91e1f2bcc17666fd3 (MD5)
Approved for entry into archive by Andrea Pereira (andrea.pereira@unipampa.edu.br) on 2017-03-13T18:18:32Z (GMT) No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Dissertação de Mestrado_Francine Nunes_2016.pdf: 2824304 bytes, checksum: aa5a2fd56f57a8f91e1f2bcc17666fd3 (MD5)
Made available in DSpace on 2017-03-13T18:18:32Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Dissertação de Mestrado_Francine Nunes_2016.pdf: 2824304 bytes, checksum: aa5a2fd56f57a8f91e1f2bcc17666fd3 (MD5) Previous issue date: 2016-06-01
A utilização de cinzas de resíduos sólidos para a fabricação de produtos cerâmicos tem apresentado evidências a fim de melhorar as propriedades químicas, físicas e mecânicas, minimizar os problemas ambientais e reduzir o volume de extração de matéria-prima argilosa. Em vista disso, o presente trabalho tem como objetivo avaliar a possibilidade de fabricar produtos cerâmicos a base de argila mais a adição de cinza de resíduo de lã de ovinos em diferentes percentuais, tendo por finalidade a aplicação na construção civil. O resíduo é proveniente do processo de beneficiamento da lã de ovinos em uma indústria têxtil, sendo que este foi queimado ao ar livre e peneirado em um conjunto de peneiras 20, 30, 40, 60 e 80 mesh. Foram realizadas formulações contendo apenas argila in natura e com adições de cinza de lã (CL) em percentagens de 5, 10, 20 e 30 % na massa de cerâmica vermelha, sendo submetidas à caracterização química pela Fluorescência de Raios-X (FRX) e Espectroscopia de Absorção na Região do Infravermelho com Transformada de Fourier (FT-IR); mineralógica com Difração de Raios-X (DRX); térmica pela Análise Termogravimétrica (TG) e Calorimetria Exploratória Diferencial (DSC); e física por meio da distribuição granulométrica e índices físicos. A conformação das amostras foi realizada por prensagem e extrusão à vácuo. E as contrações lineares de secagem e de sinterização, também foram avaliadas. A sinterização dos produtos cerâmicos foi realizada em temperaturas de 600, 700 e 800 °C, com taxa de aquecimento de 100 °Cmin-1 e patamar de sinterização de três horas. As propriedades estruturais dos produtos foram realizadas por meio de FT-IR e DRX, e a resistência mecânica pela tensão de ruptura à flexão. Outras análises físicas como contrações lineares de secagem, porosidade aparente, massa específica aparente e absorção de água, também foram avaliadas. Para a resistência mecânica a média dos valores obtidos variou de 0,38 ± 0,15 MPa a 6,70 ± 0,76 MPa, e para absorção de água, a média dos valores foi de 14,72 ± 0,39 % a 27,60 ± 1,05 %, para os produtos cerâmicos prensados. A avaliação destes mesmos parâmetros para os produtos cerâmicos extrudados, apresentou variação de 2,38 ± 1,47 MPa a 7,38 ± 3,00 MPa e de 8,57 ± 0,68 % a 24,80 ± 1,08 %. A resistência mecânica e absorção de água obtiveram melhores valores na temperatura de queima a 800 °C. No entanto, os valores encontrados foram abaixo do esperado devido aos produtos cerâmicos extrudados apresentar patologias como o “coração negro”.
The use of solid ash residue for the manufacture of ceramic products has been evidence to improve the chemical, physical and mechanical properties, minimizing environmental problems and reduce the volume of extraction clayey raw materials. In view of this, the present study aims to evaluate the possibility to make ceramics by the clay added by sheep wool waste ash, in different percentages. The purpose of this application is the construction bricks. The residue is derived from the beneficiation process of the sheep wool into a textile, and this was burnt at the air and sieved in a set of sieves 20, 30, 40, 60 and 80 mesh, only formulations were made containing clay and wool gray additions (CL) in percentages of 5, 10, 20 and 30 % in a red ceramic, being subjected to chemical characterization by X-Ray Fluorescence (XRF) and Fourier Transform in the Infrared Spectroscopy (FT-IR); Mineralogical with X-Ray Diffraction (XRD); Thermal by Thermogravimetric Analysis (TG) and Differential Scanning Calorimetry (DSC); through of physical and particle size distribution and physical indexes. The conformation of the samples was accomplished by pressing and vacuum extrusion. And the linear shrinkage by drying and heating, were also evaluated. The sintering of the ceramic products is performed at temperatures of 600, 700 and 800 °C with a the rate of 100 °Cmin -1 and three hours burning level. The structural properties of the products were performed by FT-IR and XRD, and the mechanical strength of the flexural breaking strain. Other physical analysis such as linear shrinkage drying, porosity, bulk density and water absorption were also evaluated. For mechanical strength average values obtained ranged from 0.38 ± 0.15 MPa to 6.70 ± 0.76 MPa and water absorption, the average value was 14.72 ± 0.39 % and 27.60 ± 1.05 % for the ceramics pressed. The evaluation of these same parameters for extruded ceramics, changed from 2.38 ± 1.47 MPa to 7.38 ± 3.00 MPa and 8.57 ± 0.68 % to 24.80 ± 1.08 %. The mechanical strength and water absorption values obtained in the best heating temperature to 800 °C. However, the values were lower than expected due to the extruded ceramic products present conditions as the “black core”.
APA, Harvard, Vancouver, ISO, and other styles
36

Oliveira, Nilton Fernandes de. "Avaliação da qualidade da água de lavagem de filtros e de lodo de decantador após tratamento sequencial por leito de drenagem, flotação por ar dissolvido e filtração." Universidade Federal de Uberlândia, 2015. https://repositorio.ufu.br/handle/123456789/14212.

Full text
Abstract:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
In this study, we evaluated the quality of filter backwash water and sludge decanter Water Bom Jardim Treatment Plant, located in Uberlandia, Minas Gerais, after sequential treatment with drainage bed, flotation and filtration dissolved air, all bench scale. Compounds were evaluated drainage bed effluent three different types of geotextile webs: RT-21, RT-26 and RT-31, and tested three kinds of constituents of the sand grain size filters. The effluent drained, after passage through the drainage bed, passed through the flotation unit dissolved air and then by filtration units. Preliminary tests with crude sample of filter backwash water and sludge decanter, in order to characterize it and evaluate it as its physical, chemical and biological were performed. The geotextile webs used were chosen from results of previous studies, performed with the same type of system. The experiments were divided into stages I and II. In step I were conducted without addition of coagulant or auxiliary experiments on coagulation / flocculation flotation. The samples, after passage through the system, evaluating physical parameters pH, turbidity, true color and apparent color and about the chemical parameters, remaining concentrations of aluminum and iron. Step II The same tests were carried out in the same step I and determination of quality parameters, however, with aluminum sulphate dose of 5, 10 and 15 mg / L in the coagulation / flocculation flotation. Tests conducted in step I showed better performance were performed with the RT-26 blanket in the output of filter 01 with a reduction of 91.8% of the apparent color, 41.4% of true color and 97.6% turbidity. In phase II trials conducted in the best performance was drained with the RT-mat 26 the output of the filter 02 when subjected to a dosage of 15 mg / L aluminum sulfate as a coagulant agent. There was a reduction of 96.4% of the apparent color, 86.2% of true color and 99.6% turbidity. The presented results confirm the efficiency of the system in removing solids present in the water washing of filters and ETA decanter sludge studied and confirmed the capability of using this system as an alternative to disposal or optionally for a new water supply line treated.
Neste trabalho foi avaliada a qualidade da água de lavagem de filtros e de lodo de decantador da Estação de Tratamento de Água Bom Jardim, localizada na cidade de Uberlândia-MG, após tratamento sequencial por leito de drenagem, flotação por ar dissolvido e filtração, todos em escala de bancada. Foram avaliados efluentes de leitos de drenagem compostos de três tipos de mantas geotêxteis distintas: RT-21, RT-26 e RT-31, e testados três tipos de granulometria de areia constituintes dos filtros. O efluente drenado, após passagem pelo leito de drenagem, passava pela unidade de flotação por ar dissolvido e em seguida pelas unidades de filtração. Foram realizados testes preliminares com amostra bruta da água de lavagem de filtros e de lodo de decantador, com o objetivo de caracterizá-la e avaliá-la quanto as suas características físicas, químicas e biológicas. As mantas geotêxteis utilizadas foram escolhidas a partir de resultados de trabalhos anteriores, realizados com o mesmo tipo de sistema. Os experimentos foram divididos nas etapas, I e II. Na etapa I foram conduzidos experimentos sem adição de agente coagulante ou auxiliares na coagulação/floculação da flotação. As amostras, após passagem pelo sistema, foram avaliadas quanto aos parâmetros físicos pH, turbidez, cor verdadeira e cor aparente e quanto aos parâmetros químicos, concentrações remanescentes de Alumínio e Ferro. Na etapa II foram realizados os mesmos ensaios da etapa I e mesmas determinações dos parâmetros de qualidade, entretanto, com dosagem de sulfato de alumínio de 5, 10 e 15 mg/L na coagulação/floculação da flotação. Os ensaios conduzidos na etapa I que mostraram melhor desempenho foram os realizados com a manta RT-26 na saída do Filtro 01 com redução de 91,8% da cor aparente, 41,4% da cor verdadeira e 97,6% da turbidez. Nos ensaios conduzidos na etapa II o melhor desempenho foi com o drenado da manta RT-26 na saída do Filtro 02 quando submetido a uma dosagem de 15 mg/L de sulfato de alumínio, como agente coagulante. Houve redução de 96,4% da cor aparente, 86,2% da cor verdadeira e 99,6% da turbidez. Os resultados apresentados confirmam a eficiência do sistema na remoção de sólidos presentes na água de lavagem de filtros e de lodo de decantador da ETA estudada, e confirmam a potencialidade de utilização deste sistema como alternativa ao descarte e como opção de nova linha de fornecimento de água tratada.
Mestre em Engenharia Civil
APA, Harvard, Vancouver, ISO, and other styles
37

Rivera, Juan Carlos Escobar. "Tratamento e recuperação da água de lavagem dos filtros de uma estação de filtração direta e simulação da disposição dos lodos em estações de tratamento de esgoto." Universidade de São Paulo, 2001. http://www.teses.usp.br/teses/disponiveis/18/18138/tde-24012017-145426/.

Full text
Abstract:
Foi pesquisada a aplicação de métodos, em nível de laboratório, através dos quais é possível otimizar, tratar e dispor resíduos de lavagem de filtros de estações de tratamento de água (Caso ETA do rio Descoberto - ETA-RD Brasília). Na clarificação da água de lavagem dos filtros, observou-se o efeito favorável da adição de polímero para melhorar a separação líquido-sólido é, portanto, as eficiências de remoção de turbidez, cor aparente, sólidos suspensos e coliformes totais. Observou-se melhor sedimentabilidade do lodo a ser desaguado. Os ensaios de centrifugação, em escala de bancada, mostraram que o método aplicado auxilia na determinação da dosagem a ser usada numa centrífuga em escala real. Foram avaliados três métodos de disposição do lodo adensado da ETA-RD em ETE: 1) sedimentação com esgoto sanitário e posterior digestão anaeróbia do lodo; 2) Digestão anaeróbia e 3) digestão aeróbia. Os melhores resultados foram obtidos com a digestão anaeróbia. Os estudos realizados mostraram que há diversas alternativas de tratamento e disposição desses resíduos, mas é necessário, sempre que possível, a avaliação das diferentes alternativas para selecionar a(s) mais apropriada(s) a cada caso em particular, pois fatores como custos e disponibilidade de de sistemas ou equipamentos, definirão a aplicabilidade ou não de determinado método.
It was researched the application of methods on laboratory bench scale to optimize the reuse, treatment and disposal of wastes from filter backwash of Water Treatment Plant - WTP (WTP-RD Descoberto River, Brasília case). In the clarification process of this waste, favorable effect of addition of polymer for best liquid-solid separation and, thus, better removal efficiencies of turbidity, apparent color, suspended solids and total coliforms was observed. Better sedimentability of the sludge occurred. The centrifugation tests showed that the applied method help on determination of dosagem to be used in full scale. Three methods to dispose thickened sludge of WTP-RD on wastewater treatment Plants - WWTP were evaluated: 1) Sedimentation with domestic sewage and anaerobic digestion of sludge; 2) Anaerobic digestion and 3) Aerobic digestion. Best results were obtained with anaerobic digestion. The results showed that there are alternatives of treatment and disposal of wastes of WTP, but is necessary, if possible, to make the evaluation of this alternatives to select the most appropriate(s) in each case because factors as costs, systems or equipments availability, will define the applicability or not of a particular method.
APA, Harvard, Vancouver, ISO, and other styles
38

Ogura, Allan Pretti. "Avaliação e tratamento da água de lavagem dos filtros e dos resíduos sedimentados gerados pela tecnologia de ciclo completo contendo oocistos de Cryptosporidium spp. e cistos de Giardia spp." Universidade de São Paulo, 2018. http://www.teses.usp.br/teses/disponiveis/18/18138/tde-22062018-160943/.

Full text
Abstract:
Os oocistos de Cryptosporidium spp. e os cistos de Giardia spp. podem gerar doenças de veiculação hídrica associadas a problemas de saúde pública. Os (oo)cistos são de difícil remoção e inativação durante o tratamento de água, principalmente devido ao tamanho reduzido e à resistência ao processo de cloração. Além disso, os métodos de detecção de protozoários na água apresentam elevado custo e estão sujeitos à grande variabilidade e à baixa reprodutibilidade, especialmente em águas de elevada turbidez. Com água de estudo com turbidez de aproximadamente 110 uT, ensaios de tratabilidade com cloreto de polialumínio foram feitos em jarteste para a obtenção da água de lavagem dos filtros (ALF) e do resíduo sedimentado. O método escolhido para detecção de (oo)cistos foi a centrifugação direta com adição de solução de dispersão ICN 7X seguido de IMS com duas dissociações ácidas (CD + ICN 7X). O tratamento dos resíduos objetivou a inativação dos (oo)cistos, por meio de danos à estrutura celular dos parasitos, identificada pela incorporação do corante iodeto de propídio no microrganismo. Para o método CD + ICN 7X, menor interferência na viabilidade dos (oo)cistos foi observada em relação à floculação em carbonato de cálcio e melhor recuperação do que a centrifugação direta. O controle de qualidade analítica desse método, feito com suspensão do kit EasySeed®, apresentou recuperação de 2,8±0,8% de oocistos e 7,8±2,9% de cistos para a ALF e de 3,3±2,0% e 24,8±8,0%, para oocistos e cistos no resíduo sedimentado. Apenas a recuperação de cistos de Giardia spp. no resíduo sedimentado atendeu aos padrões recomendados pelo Método 1623.1 da USEPA. A presença de microesferas magnéticas aderidas aos (oo)cistos foi observada nos poços de leitura após a IMS, indicando limitações desse método de purificação. Para o tratamento alcalino do resíduo sedimentado, a dosagem de 27mg/100mL foi testada para os tempos de 3 e 5 dias e, respectivamente, foram obtidos 1,85 e 3,0 log de inativação de oocistos e 2,05 e 2,14 log de inativação para cistos. Para o processo de ozonização da ALF, avaliado apenas para oocistos, as inativações de 2,83 log e 3,44 log foram obtidas para as dosagens de 7,5 mg O3 L-1 por 10 min e 10 mg O3 L-1 por 5 min, respectivamente.
Cryptosporidium spp. oocysts and Giardia spp. cysts are infectious forms and can cause public health problems due to associated waterborne diseases. (Oo)cysts are difficult to remove and inactivate during water treatment, mainly because of reduced size and resistance to chlorination. In addition, protozoan detection methods in water are expensive and subject to high variability and low reproducibility, especially in high turbidity water. In jartest treatability tests, 110 uT study water was treated with polyaluminium chloride to obtain backwashing water (BW) and sedimented residue. The method chosen for detection of (oo)cysts was direct centrifugation with addition of 7X ICN dispersion solution followed by IMS with two acid dissociations. Treatment of residuals objectified inactivation of (oo)cysts by damages on parasites cellular structure, identified by inclusion of propidium iodide as an indicator. The method of detection chosen showed less interference in the viability of (oo)cysts in comparison to flocculation in calcium carbonate and better recovery than direct centrifugation. The analytical quality control of this method, performed with EasySeed® suspension, obtained recovery of 2.8±0.8% oocysts and 7.8±2.9% cysts for BW and of 3.3±2.0% and 24.8±8.0%, for oocysts and cysts in sedimented residue. Only Giardia spp. recovery in sedimented residue complied with the standards recommended by USEPA Method 1623.1. Magnetic microspheres were found attached to (oo)cysts in microscope slides after IMS, indicating limitations of this purification method. For the alkaline treatment of sedimented residue, dosage of 27mg / 100mL was tested for 3 and 5 days and respectively 1.85 and 3.0 log inactivation were obtained for oocysts while 2.05 and 2.14 log of. For ozonation of BW, evaluated only for oocysts, 2.83 log and 3.44 log inactivation were obtained for dosages of 7.5 mg O3 L-1 for 10 min and 10 mg O3 L-1 for 5 min, respectively.
APA, Harvard, Vancouver, ISO, and other styles
39

Costa, Filho Batuira Martins da. "Aplicação do processo de floculação combinado ao processo foto-fenton para o tratamento do efluente proveniente da lavagem de um reator utilizado na produção do inseticida Fipronil." Universidade Federal de Uberlândia, 2014. https://repositorio.ufu.br/handle/123456789/17419.

Full text
Abstract:
Fundação de Amparo a Pesquisa do Estado de Minas Gerais
In this work, was evaluated the treatment of the effluent from a fipronil insecticide production plant by a process that consists of two parts: initially a conventional treatment step, by flocculation, was carried out in order to remove suspended solids. For that, were tested the concentrations of 40, 80, 160, 240 e 320 mg L-1, of the flocculant (FeCl3), obtaining the highest solid and fipronil removal efficiency when the 160 mg L-1 concentration was used. Once this first treatment step was done, was evaluated the photodegradation by photo-Fenton process, using artificial UV irradiation. The process efficiency was monitored by fipronil concentration decay, determined by high performance liquid chromatography (HPLC), removal of organic load given by dissolved organic carbon (DOC), chemical oxygen demand (COD) decay and H2O2 consumption. In addition, acute toxicity tests were performed, using the microcrustacean Artemia salina. The H2O2 concentrations of 2241, 2689, 3362, 4482 e 6723 mg L-1 were evaluated, according to the efficiency and kinetic of organic matter decay. With the increasing of H2O2 concentration, was observed an enhancement on degradation efficiency, therefore, the highest degradation efficiency was achieved when the highest H2O2 concentration was used. In a second moment was tested, the amount of Fe2+, among concentrations of 15, 45 e 60 mg L-1, the concentration of 60 mg L-1 presented the best DOC and COD removal results. The organic load effect on the degradation process was also evaluated, the effluent was diluted to 20, 15 and 5% in total volume, then experiments under the previously determined conditions, [Fe2+] = 60 mg L-1 and [H2O2] = 6732 mg L-1, was carried out. The best removal efficiency and kinetic results was obtained by the highest organic load tested. With the parameters optimized, the evolution of acute toxicity to Artemia salina was monitored during the photo-Fenton degradation. A decrease of toxicity from 100 to 13% at the first hour of reaction was observed. Based on these results, it can be stated that the coupling between the flocculation and photo-Fenton processes, can be considered as a good alternative for the treatment of this kind of effluent, once it gives high efficiency on suspended solid, fipronil, organic matter and toxicity removal.
Neste trabalho foi avaliado o tratamento do efluente da produção do inseticida fipronil por um processo composto por duas etapas: inicialmente uma etapa convencional, a qual é constituída por tratamento de floculação, para remoção dos sólidos em suspensão. Para tanto foram avaliadas as concentrações de 40, 80, 160, 240 e 320 mg L-1 do agente floculante (FeCl3) obtendo-se maior eficiência de remoção de sólidos suspensos e fipronil, quando a concentração de 160 mg L-1 de FeCl3 foi utilizada. Em um segundo momento, foi avaliada a fotodegradação da matéria orgânica remanescente pelo processo foto-Fenton, utilizando irradiação UV artificial. A eficiência do processo de fotodegradação foi monitorada pelo decaimento da concentração de fipronil, determinada por cromatografia líquida de alta eficiência, remoção da carga orgânica dada pelo decaimento da concentração de carbono orgânico dissolvido (COD), demanda química de oxigênio (DQO), e, consumo de H2O2. Além disso, foram feitos testes de toxicidade aguda utilizando microcrustáceos de Artemia salina. Foram avaliadas as concentrações de H2O2 (2241, 2689, 3362, 4482 e 6723 mg L-1), em função da velocidade e eficiência da remoção da carga orgânica. A eficiência da remoção da carga orgânica aumentou seguindo o aumento da concentração de H2O2, sendo que a melhor eficiência foi alcançada com a concentração de 6723 mg L-1. Além disso, também foi avaliada a concentração de Fe2+ (15, 45 e 60 mg L-1). Dentre as concentrações testadas, a concentração de 60 mg L-1 foi a que promoveu melhores resultados de remoção de DQO e COD. A influência da carga orgânica no processo de degradação foi avaliada com o efluente diluído em 20, 15 e 5% em volume, sob as melhores concentrações determinadas previamente, [Fe2+] = 60 mg L-1 e [H2O2] = 6732 mg L-1, obtendo-se melhor eficiência de degradação para o efluente com a maior carga orgânica. Sob condições otimizadas, também foi avaliada a evolução da toxicidade aguda para A. salina, durante a aplicação do processo foto- Fenton. Foi observado que a toxicidade aguda diminuiu de 100 para 13% após 60 min de reação. Com base nos resultados obtidos, pode ser observado que o acoplamento entre os processos de floculação e foto-Fenton pode ser uma boa alternativa para o tratamento deste tipo de efluente, uma vez que houve alta eficiência na remoção de sólidos suspensos, fipronil, matéria orgânica e toxicidade.
Mestre em Química
APA, Harvard, Vancouver, ISO, and other styles
40

Silva, Hugo Guilherme. "Avaliação e tratamento de oocistos de Cryptosporidium spp. e cistos de Giardia spp. presentes na água de lavagem dos filtros e no resíduo flotado gerados pela tecnologia de ciclo completo com flotação por ar dissolvido." Universidade de São Paulo, 2018. http://www.teses.usp.br/teses/disponiveis/18/18138/tde-18062018-105134/.

Full text
Abstract:
O presente trabalho avaliou o uso e a detecção de óxido de cálcio e ozônio para a inativação de cistos de Giardia spp. e oocistos de Cryptosporidium parvum presentes nos resíduos e na água de lavagem dos filtros gerados após a utilização da tecnologia de ciclo completo com flotação por ar dissolvido (coagulação, floculação, flotação e filtração) em escala de bancada, usando o cloreto de polialumínio PAC como coagulante. Para os ensaios analíticos de recuperação dos protozoários e validação do método foram utilizados as suspensões e o Easyseed® nas matrizes ALF e resíduos. A quantificação dos protozoários foi realizada pelo método de centrifugação direta com a adição de solução de dispersão detergente ICN 7X (MP BIO®) a 1,0% na amostra com a etapa de separação imunomagnética – IMS. As recuperações nos ensaios de qualidade utilizando as suspensões de protozoários foram de 19,86% ± 16,29 e 43,95% ± 11,21, para oocistos de Cryptosporidium e cistos de Giardia respectivamente na matriz ALF, enquanto que para a matriz resíduo foram de 8,16% ± 30,24 para Cryptosporidium e 32,54% ± 46,48 para Giardia. Para os ensaios de recuperação empregando o Easyseed® os valores da matriz ALF foram 2,25% ± 1,37 para Cryptosporidium e 3,75% ± 2,25 para Giardia. No resíduo, a recuperação foi de 4,5% ± 1,50 para Cryptosporidium e 49% ± 1 para Giardia. Para os ensaios com óxido de cálcio na matriz resíduo, a primeira condição com dosagem de 23 mg cal/100mL no tempo de contato de 3 dias a 25° C, não foram encontrados protozoário positivo para o teste IP (iodeto de propídeo), o que deixa esta condição satisfatória. Na segunda condição, com dosagem de 16 mg cal/100mL e tempo de contato de 3 dias a 25°C, foram encontrados protozoários negativos para IP. Para as condições de desinfecção, utilizando ozônio, com tempos de contato 5 min e 10 min e dosagens de 10 mg O3.L-1 e 7,5 mg O3.L-1, respectivamente, poucos organismos foram detectados. Portanto, destaca-se a dificuldade em avaliar a permeabilidade dos protozoários após os ensaios de desinfecção realizados. Faz-se necessário realizar novos ensaios com outras dosagens e tempos de contato.
The present work evaluated the use of calcium oxide and ozone for the inactivation of Giardia spp. and Cryptosporidium parvum oocysts present in the wastes and in the wash water of the filters obtained after the use of the complete cycle technology with dissolved air flotation (coagulation, flocculation, flotation and filtration) on a bench scale using polyaluminium chloride - PAC as a coagulant. For the analytical tests of protozoan recovery and validation of the method, suspensions and Easyseed ® were used in the ALF and residues matrices. Protozoan quantification was performed by the direct centrifugation method with the addition of detergent dispersion solution ICN 7X (MP BIO ®) at 1.0% in the sample with the immunomagnetic separation step - IMS. The recoveries in the quality assays using the protozoal suspensions were 19.86% ± 16.29 and 43.95% ± 11.21 for Cryptosporidium oocysts and Giardia cysts respectively in the ALF matrix, whereas for the residue matrix were 8.16% ± 30.24 for Cryptosporidium and 32.54 ± 46.48 for Giardia. For the recovery assays using Easyseed ® the ALF matrix values were 2.25% ± 1.37 for Cryptosporidium and 3.75% ± 2.25 for Giardia. In the residue, recovery was 4.5% ± 1.50 for Cryptosporidium and 49% ± 1 for Giardia. For the calcium oxide assays in the residue matrix, the first condition with a dosage of 23 mg cal/100mL at the contact time of 3 days at 25°C, no positive protozoan was found for the IP (propidium iodide) test, which leaves is a satisfactory condition. In the second condition with a dosage of 16 mg cal/100mL and contact time of 3 days at 25°C, negative protozoa were found for IP. For the disinfection conditions using ozone with contact times 5 min and 10 min and dosages of 10 mg O3.L-1 and 7.5 mg O3.L-1, respectively, few organisms were detected. Therefore, the difficulty in evaluating the permeability of protozoa after the disinfection tests carried out. Realization of new tests with other dosages and contact times.
APA, Harvard, Vancouver, ISO, and other styles
41

Gonçalves, João David Moreira da Cunha. "Estudo dos efeitos da colmatação parcial do ralo de sistemas sifónicos de drenagem de coberturas." Master's thesis, Universidade de Aveiro, 2016. http://hdl.handle.net/10773/17856.

Full text
Abstract:
Mestrado em Engenharia Civil
Os sistemas sifónicos de drenagem de coberturas permitem, através de ralos de depressão, o escoamento de quantidades de água significativamente superiores às drenadas por sistemas convencionais de iguais dimensões. No entanto, se colmatados, os ralos perdem grande parte da sua eficiência. Este trabalho pretende avaliar a eficiência de escoamento de um sistema de drenagem sifónica de águas pluviais em coberturas com colmatação parcial. Os ensaios foram realizados recorrendo a uma torre hidráulica com um sistema de drenagem sifónica de águas pluviais em coberturas. Foram realizados ensaios com 80%, 100%, 120% e 140% do caudal de dimensionamento, com colmatação apenas lateral, com colmatação lateral e no topo e por último com colmatação apenas no topo. Os resultados obtidos evidenciam que todos os caudais ensaiados seguem uma tendência de crescimento até uma percentagem de colmatação de 85% após a qual o comportamento se altera. Verificou-se como indiferente, por si só, a colmatação apenas no topo do ralo sifónico. A colmatação no topo quando associada com a colmatação lateral, mostrou diferenças notórias no desempenho do escoamento face à colmatação apenas lateral. Por fim, comprova-se que a elevada percentagem de colmatação tem influência no regime de escoamento, chegando mesmo a anular o efeito sifónico.
Through specially engineered roof drain baffles, siphonic roof drainage systems allow a greater water drainage compared to conventional systems of equal dimensions. However, if blocked, the drains lose much of their efficiency. This work intends to evaluate the drainage efficiency of a siphonic roof drainage system partial blockage. The experience was carried out in a test facility with an incorporated siphonic drain baffle. Tests were made with design flow rates of 80%, 100%, 120% and 140%, with lateral, lateral and top and top blockages. The results show that all the flow rates tested follow a growth trend up to an 85% blockage, after which the behavior changes. The tests with the blockage only at the top of the siphonic drain baffle showed no differences on its own. Blockage at the top, when associated with lateral blockage, showed strong differences in flow performance when compared with lateral only blockage. In conclusion, the greater the blockage, the lower the efficiency of the drainage system; the blockage percentage influences the flow and can even annul the fullbore flow and siphonic action.
APA, Harvard, Vancouver, ISO, and other styles
42

Lotto, Mariana de Castro. "Avaliação da contaminação de alface (Lactuca sativa) por coliformes termotolerantes e Escherichia coli em sistemas de cultivo orgânico e convencional." Universidade Federal de São Carlos, 2008. https://repositorio.ufscar.br/handle/ufscar/47.

Full text
Abstract:
Made available in DSpace on 2016-06-02T18:57:20Z (GMT). No. of bitstreams: 1 2330.pdf: 2747102 bytes, checksum: 42b3374c620038a839a3f3c1d80f9df0 (MD5) Previous issue date: 2008-12-15
Financiadora de Estudos e Projetos
Lettuce (Lactuca sativa) is the most consumed vegetable in Brazil, being classified as an important food, to be a rich source of vitamins. According to the practices adopted, its cultivation can be organic or conventional. However, lettuce can be a transmitter of pathogenic microorganisms to humans, as thermotolerant coliforms and Escherichia coli, since it is in contact with these contaminants often present in soil, water, in natural inputs (poultry litter) providing their development and survival. This research aimed to assess quantitatively the presence of thermotolerant coliforms and E. coli in water for irrigation and washing water, and the not washed and washed lettuce, grown under organic and conventional systems. The samples were collected in ten farms, five under organic and five under conventional systems, located at the cities of Ibiúna, Jaguariúna, Campinas e Morungaba - SP. In the laboratory, the samples were submitted to the analysis by the technique of counting the Most Probable Number. The results show that water for irrigation was considered one of the main factors responsible for contamination of lettuce, as showed by the presence ofhigh rate of thermotolerant coliforms and E. coli, independent of the cultivation system. However, the conventional system had been showing levels of contamination by thermotolerant coliforms and E. coli in water higher thanin organic system. In lettuce, pre washing contributed to the reduction of contamination by thermotolerant coliforms and E. coli in the product; however contamination by thermotolerant coliforms was considered high in the both cultivation systems. Moreover, others practices used in the farm such as personal hygiene, the inappropriate use of compost and the presence of animals in the areas of crops are source of contamination.
A alface (Lactuca sativa) é a hortaliça folhosa mais consumida no Brasil, sendo classificada como um importante alimento para a população por ser uma rica fonte de vitaminas. Em função das práticas adotadas, o seu cultivo pode ser orgânico ou convencional. No entanto, alface pode ser um veículo transmissor de microrganismos patogênicos ao homem, como coliformes termotolerantes e Escherichia coli, uma vez que se encontra em contato com esses contaminantes presentes freqüentemente no solo, na água, nos insumos naturais (cama de frango) propiciando o desenvolvimento e a sobrevivência dos mesmos. O objetivo deste trabalho foi avaliar, quantitativamente, a presença de coliformes termotolerantes e de E.coli em água de irrigação e de pré-lavagem, assim como, o produto alface não lavada e pré-lavada, cultivada sob cultivo orgânico e convencional, em relação à recomendação da ANVISA. As coletas foram realizadas em dez propriedades, cinco de cultivo orgânico e cinco de cultivo convencional, localizadas nas cidades de Ibiúna, Jaguariúna, Campinas e Morungaba - SP. Em laboratório, as amostras foram submetidas à análise de tubos múltiplos e série bioquímica e procedeu-se a avaliação pela técnica de contagem do Número Mais Provável. Os resultados mostraram um alto índice de coliformes termotolerantes e E. coli na água de irrigação, sendo um fator importante pela contaminação da alface, independente do sistema de cultivo. Todavia, o cultivo convencional apresentou índices de contaminação por esses microrganismos na água superiores ao do cultivo orgânico. No produto alface, a pré-lavagem contribuiu para a redução da contaminação por coliformes termotolerantes e E. coli, entretanto a contaminação pelo primeiro foi mais alta em ambos os sistemas de cultivos. Além disso, outras práticas utilizadas nas propriedades como a higiene pessoal, o uso de adubos compostados inadequados e a presença de animais nas áreas de cultivo são fontes de contaminação.
APA, Harvard, Vancouver, ISO, and other styles
43

Bexiga, Anabela da Coceição Rosado. "Qualification of affluent loads to Alqueva-Pedrogão system." Master's thesis, Universidade de Évora, 2008. http://hdl.handle.net/10174/18349.

Full text
Abstract:
Este estudo permitiu identificar que em Portugal e Espanha existem inúmeras fontes de poluição urbanas e agrícolas, que contribuíram para a degradação da água do Sistema Alqueva-Pedrógão. As cargas poluentes armazenadas no solo, durante o período seco, foram arrastadas para as linhas de água no período chuvoso. A primeira enxurrada originou o arrastamento de partículas sólidas, do meio terrestre para o meio aquático, provocando um aumento significativo de SST e MO. As cargas de N, P, CB05 e CQO surgiram em maiores quantidades em situações de caudal-base originadas pelas descargas de águas residuais das povoações próximas. A Albufeira de Alqueva alcançou maiores taxas de retenção do que a Albufeira de Pedrógão, no global, o sistema conseguiu retenções consideráveis. Este estudo reforçou a ideia que é necessário, aplicar planos de monitorização sustentáveis nas sub-bacias para minimizar os impactos nas linhas de água e nos reservatórios armazenadores, para conseguir os objectivos da Directiva Quadro da Agua. ABSTRACT; This study allowed the identification of countless punctual urban and agricultural pollution sources that contribute for the water degradation in Alqueva-Pedrógão System both in Portugal and Spain. The flood situation, originated the dragging of solid particles of the terrestrial environment into the aquatic, originating a significant increase of TSS and OM. The loads of N, P, BOD and COO are present ln larger amounts in base-flow situations originated from wastewaters discharges from nearby villages. The Alqueva Reservoir had larger retention rates than Pedrogão Reservoir but, in total, the system presented considerable retention. This study emphasized the idea that there is an urgent need to apply sustainable monitoring plans in the sub-basins, in order to minimize the impacts in the streams and the reservoirs, to achieve the gold's of the Water Framework Directiva.
APA, Harvard, Vancouver, ISO, and other styles
44

Fernandes, Cássia Carolina Ricardo. "Contribuição para a otimização da operação de lavagem em biofiltros: Tecnologia BIOSTYR®." Master's thesis, 2016. http://hdl.handle.net/10362/23046.

Full text
Abstract:
A biofiltração é uma tecnologia que combina o processo físico de filtração com a remoção biológica de matéria orgânica dissolvida. Apesar de já ser uma tecnologia com inúmeras referências no tratamento de águas residuais, os processos biológicos que ocorrem no interior de um biofiltro continuam a ser objeto de investigação. Com o objetivo de contribuir para o aprofundamento do conhecimento das condições ótimas de processo, foram realizadas várias campanhas na tentativa de otimizar o tratamento biológico utilizado na ETAR de Alcântara: Tecnologia BIOSTYR® da Veolia Water Solutions. Foram analisados os vários parâmetros operacionais: tempos de lavagem, cargas hidráulicas, número de ciclos de lavagem, bem como a repercussão da operação de lavagem na eficácia do tratamento. Foram considerados os seguintes cenários para alterações processuais: (i) alteração da velocidade de lavagem de 60 m/h para 50 m/h; (ii) alteração do tempo de lavagem apenas com água de 150 para 130 segundos; (iii) alteração do tempo de lavagem apenas com água de 130 para 140 segundos; (vi) alteração do tempo de lavagem apenas com água de 140 para 135 segundos; (v) alteração do tempo da fase de enxaguamento de 300 para 270 segundos. Foram avaliados os efeitos das alterações processuais ao longo do tempo e o seu impacto na qualidade do efluente final. Os resultados obtidos permitiram concluir que a ETAR de Alcântara apresenta uma capacidade de remoção orgânica para o CBO5, CQO, e SST, superior aos valores teóricos definidos em projeto, tanto em tempo seco como em tempo húmido. Foram identificados os biofiltros que aparentam ter um desempenho inferior comparativamente com os restantes bem como quais os cenários que apresentam uma maior margem para otimização.
APA, Harvard, Vancouver, ISO, and other styles
45

Ferreira, Jessica Alexandra dos Anjos. "Otimização da lavagem ácida do mononitrobenzeno." Master's thesis, 2018. http://hdl.handle.net/10316/86404.

Full text
Abstract:
Dissertação de Mestrado Integrado em Engenharia Química apresentada à Faculdade de Ciências e Tecnologia
O mononitrobenzeno (MNB) é um produto químico resultante da reação de nitração de benzeno com ácido nítrico na presença de ácido sulfúrico, o catalisador. Numa etapa posterior à reação de nitração, o MNB bruto é separado da fase aquosa, constituída principalmente por água e ácido sulfúrico. Entre outras impurezas do processo, nomeadamente nitrofenóis (NFs), o MNB bruto arrasta consigo vestígios de ácido sulfúrico. Este ácido mineral tem de ser removido para evitar emissões gasosas de dióxido de enxofre na etapa de tratamento de efluentes por incineração.A separação do ácido sulfúrico é efetuada num processo de lavagem que consiste numa extração líquido/líquido recorrendo a água com pH ácido. Desta lavagem ácida resulta um caudal de efluente a ser tratado, sendo de todo o interesse otimizar a quantidade de solvente utilizado. Para tal, na unidade de lavagem do MNB, a água deve ser reciclada, o que aumenta continuamente a sua concentração no ácido sulfúrico extraído até ser atingido o estado estacionário. Para além da evidente vantagem de redução de caudal de efluente e, por consequência, redução do caudal de água de make-up, no lavador a funcionar em contra-corrente, a concentração de ácido sulfúrico no efluente aquoso aumenta. Uma vez que o processo reutiliza o ácido sulfúrico nos reatores, a água a remover na reconcentração diminui. Por outro lado, na eventualidade de parte desta água de lavagem ser purgada, a concentração em NFs nesta corrente será inferior devido à menor solubilidade destes compostos em água com maior concentração de ácido sulfúrico. Este último parâmetro é muito importante para manter as obrigações ambientais. Este trabalho, desenvolvido na empresa Bondalti, centrou-se no estudo das condições operatórias para melhorar a qualidade do MNB à saída da lavagem ácida no teor de ácido sulfúrico e NFs.No processo industrial em funcionamento, o MNB à saída da unidade de lavagem ácida é designado por MNB ácido. A extração de ácido sulfúrico ainda presente neste MNB foi avaliada num estudo à escala laboratorial tendo em consideração as variáveis do processo de extração. A concentração de ácido sulfúrico na água de lavagem é um dos parâmetros e concluiu-se que a eficiência da extração não é afetada quando a água de lavagem utilizada tem níveis de ácido sulfúrico inferiores a 0,32%. Por outro lado, para águas de lavagem com concentrações em ácido sulfúrico que variaram entre 0,32 e 1,1%, a concentração de ácido sulfúrico no MNB resultante da unidade de lavagem ácida em estudo aumenta pouco significativamente com a acidez da água de lavagem. Para concentrações de ácido sulfúrico na água de lavagem acima deste valor, é visível um maior impacto na eficiência de extração deste composto. A possibilidade de alterar a razão volumétrica entre as fases orgânica (MNB ácido) e aquosa (água de lavagem) foi também averiguada. Para este teste utilizou-se a mesma quantidade de água para lavar diferentes volumes de MNB ácido. A razão de fases revelou ter pouco impacto numa gama muito alargada. Para uma razão de fases elevada, de 2,2, verificou-se uma drástica diminuição da eficiência de extração.A solubilidade do ácido sulfúrico nas fases orgânica e aquosa em análise depende da temperatura. Todavia, o impacto desta condição operatória sobre o sistema de lavagem líquido/ líquido não teve um efeito significativo no estudo que decorreu na gama de temperatura de 8 a 36.Estudou-se também a influência do tempo de decantação na eficiência de lavagem observando-se que, na gama avaliada, este parâmetro não produz um efeito notório na extração de ácido sulfúrico do MNB ácido.A influência destas variáveis operatórias sobre o teor de NFs na água de lavagem foi também analisada tendo-se concluído não ser relevante. Esta conclusão está de acordo com a reduzida solubilidade dos NFs em meios ácidos.A informação recolhida sobre as melhores condições operatórias permitiu ter dados para uma análise global do processo de lavagem ácida em estudo. Esta avaliação baseou-se em balanços mássicos ao sistema e na determinação das relações entre os caudais das principais correntes. Concluiu-se que, implementando na fábrica o sistema de lavagem ácida do MNB que foi estudado, a utilização de uma água de lavagem com até 1,1% de ácido sulfúrico permite minimizar o caudal de efluente aquoso bem como o caudal de água de make-up a alimentar à unidade de lavagem.
Mononitrobenzene (MNB) is a chemical product resulting from the nitration reaction of benzene with nitric acid in the presence of sulfuric acid, the catalyst. After the nitration reaction, the crude MNB is separated from the aqueous phase, consisting mainly of water and sulfuric acid. Among other process impurities, namely nitrophenols (NPs), the crude MNB carries with it traces of sulfuric acid. This mineral acid needs to be removed to avoid gaseous emissions of sulfur dioxide during effluent treatment by incineration.The withdrawal of this compound occurs in a washing process based on liquid/ liquid extraction using water with acidic pH. From this acidic washing results an effluent, which has to be disposed, and it is important to optimize the amount of solvent used. In order to do this, in the MNB washing unit, the water must be recicled, and this continuously increases its concentration in the extracted sulfuric acid until steady state is reached. In addition to the obvious advantage of reducing effluent volume and consequently reducing the make-up water flow rate, when the washer operates countercurrently, the concentration of sulfuric acid in the aqueous effluent builds up. Thus, the requirements to increase concentration of sulfuric acid prior to reuse in the reactors are minimal. On the other hand, in case this washing water is purged, the concentration of NPs in this stream will be lower due to the reduced solubility of these NPs in water with higher concentration of sulfuric acid. This last parameter is very important due to environmental footprint. This work, developed at Bondalti, focused on the study of the operating conditions to improve the quality of MNB leaving the acidic washing by reducing sulfuric acid and NPs contents.In the existing industrial process, the MNB leaving the acidic washing unit is named as acidic MNB. The extraction of sulfuric acid still present in this MNB was evaluated in a laboratory scale study considering the variables of the extraction process. The concentration of sulfuric acid in the washing water is one of the parameters and it has been confirmed that the extraction efficiency is not compromised when the washing water has levels of sulfuric acid below 0,32%. On the other hand, for washing waters with concentrations of sulfuric acid ranging from 0,32 to 1,1%, the concentration of sulfuric acid in the resulting MNB increases slightly with the acidity of the washing water. For sulfuric acid concentrations in the washing water above this value, a greater impact on the extraction efficiency of this compound is undeniable.The possibility of changing the volumetric ratio between the organic (acidic MNB) and aqueous (washing water) phases was also investigated. In these tests, the same amount of water was used to wash different volumes of acidic MNB. The phase ratio was found to have a little impact over a very wide range. For a high phase ratio of 2,2, there was a noticeable decrease in the extraction efficiency.The solubility of the sulfuric acid in the organic and aqueous phases under analysis depends on the temperature. However, the impact of this operating condition on the liquid/ liquid washing system did not have a significant effect in the study that was conducted in the temperature range of 8 to 36.The influence of the decantation time on washing efficiency was also studied. In the range considered, this parameter did not produce a noticeable effect on the extraction of sulfuric acid from the acidic MNB.The influence of these operating variables on the NPs content in the washing water was also analyzed and it was concluded that it was not relevant. This conclusion is in agreement with the reduced solubility of NPs in acidic mediums.The information collected about the best operating conditions allowed to get data for an overall analysis of the acidic washing process under study. This assessment was based on mass balances and the determination of the relationships between the flows of the main streams. It was concluded that by implementing at the plant the studied MNB acidic washing system, the use of washing water with up to 1,1% sulfuric acid allows to minimize the aqueous effluent flow rate as well as the make-up water flow rate to be fed to the washing unit.
APA, Harvard, Vancouver, ISO, and other styles
46

Gomes, Cátia Sofia Vieira. "Monitorização e impactes antropogénicos sobre a qualidade da água em ribeiras de caudal permanente na ilha de São Miguel (Açores)." Master's thesis, 2013. http://hdl.handle.net/10400.3/2044.

Full text
Abstract:
Dissertação de Mestrado em Ambiente, Saúde e Segurança.
A água constitui um recurso natural essencial à vida e apesar de esta ocupar, aproximadamente, 70% da superfície terrestre, a percentagem de água utilizável pelo Homem é muito reduzida. Para além do consumo doméstico, a água é, ainda, utilizada em todas as atividades económicas, como por exemplo a agricultura e a indústria, o que gera pressões quantitativas e qualitativas, essencialmente associadas no primeiro caso à captação e no segundo caso à emissão de águas residuais. Estas situações acarretam impactes a vários níveis, desde alterações de caudais, modificações hidromorfológicas, poluição química e biológica e alteração das condições ecológicas pritinas. Em resposta a uma crescente consciencialização relativamente às questões supramencionadas foram elaborados documentos normativos e legislativos, a nível europeu, nacional e regional, com o intuito de despoletarem programas com a finalidade de avaliar e proteger os recursos hídricos. Após esta avaliação pretende-se estabelecer medidas preventivas e corretivas e garantir que exista um efetivo desenvolvimento sustentável. O presente trabalho aborda a temática da qualidade das águas das ribeiras de caudal permanente da ilha de São Miguel, e pretende caracterizar o estado químico da água e avaliar os impactos antropogénicos sobre a qualidade da mesma. Esta dissertação envolveu um total de seis ribeiras, que correspondem a nove massas de água. Para a caracterização procedeu-se à análise e tratamento de dados cedidos pela Administração Hidrográfica dos Açores, que abrangem o período entre 2003 e 2011. Do tratamento dos dados da monitorização conclui-se que a atividade agropecuária e a drenagem de águas residuais são as principais fontes poluidoras antropogénicas das águas superficiais, uma vez que se verificam concentrações elevadas de fósforo total, nitratos, nitritos e do parâmetro CBO5. Os metais e os hidrocarbonetos apresentam valores inferiores ao limite de quantificação, o que permite inferir que o seu impacte é pouco significativo. Os resultados também permitem verificar que existe uma relação entre a qualidade da água e a ocupação do solo, constatando-se que os locais mais interiores são os que apresentam menor poluição, visto que correspondem a áreas em que predomina vegetação natural e floresta. No entanto, as áreas mais planas e próximas do litoral apresentam maior poluição devido às pastagens e aos aglomerados populacionais.
ABSTRACT: Water is a natural resource essential to life, and despite 70% of the Earth surface been occupied by water the proportion able to support human activities is much lower. Besides domestic use, water is also needed to economic activities, like industry and agriculture, which causes quantitative and qualitative pressures, as abstraction or waste water uncontrolled discharge, causing diverse types of impacts, from discharge variation, hydromorphological modifications, chemical and biological pollution and deterioration of the ecologic pristine conditions. Due to the increasing awareness in what concerns the questions addressed above, several regulation and legislation documents were published at regional, national and international levels, in order to develop programmes of evaluation and protection of water resources. After this evaluation, the overall objective is to establish preventive and corrective measures, in order to attain an effective sustainable development. The present thesis addresses water quality in river water bodies in São Miguel Island, namely characterizing water bodies status and evaluate anthropogenic impacts over water quality. A total of six rivers were studied, corresponding to nine water bodies, and data provided by the Hydrographic Administration of the Azores, corresponding to a time interval between 2003 and 2001, was analyzed. From the analysis made it was possible to conclude that livestock activity and waste water discharge are the main pollution sources that impact river water quality, depicted by high phosphorous, nitrate, nitrite content as well as by high values of BOD5. Heavy metals and hydrocarbons are usually under detection limit, showing that are negligible to water quality. Results also show a close relationship between water quality and land use, with inland areas, dominated by pristine forests and natural vegetation, where rivers have non-polluted waters. In opposition, in the lowland areas, pollution levels are higher due to pasture land dominance and to urban development.
APA, Harvard, Vancouver, ISO, and other styles
47

Marques, Raquel Alexandra Pinto. "Análise e otimização do processo de lavagem de uma central de engarrafamento de bebidas." Master's thesis, 2016. http://hdl.handle.net/10316/40263.

Full text
Abstract:
Dissertação de Mestrado Integrado em Engenharia Química apresentada à Faculdade de Ciências e Tecnologia da Universidade de Coimbra.
No âmbito da unidade curricular Dissertação do Mestrado Integrado em Engenharia Química da Universidade de Coimbra surgiu a possibilidade de realizar esta tese na empresa Goanvi - Central de Engarrafamento de Bebidas, tendo sido adotado o tema: “Análise e Otimização do Processo de Lavagem de uma Central de Engarrafamento de Bebidas”. Mais concretamente, o trabalho envolveu o estudo da remoção da dureza da água através de processos de precipitação química e permuta iónica, bem como a análise económica referente ao consumo de produtos de higienização nesta empresa. O estudo do processo de precipitação química envolveu a análise do efeito da quantidade de Ca(OH)2 adicionado às amostras de água assim como o efeito da adição de coagulante. No processo de permuta iónica realizou-se um estudo de equilíbrio e da cinética do processo em batch, utilizando a resina catiónica Amberlite IR-120 Na+. A operação em leito fixo e a etapa de regeneração em batch foram também estudadas. Os resultados experimentais indicaram que o método de precipitação química permite obter água com dureza de 100 mg L-1 de CaCO3 e que a adição de coagulante não tem influência significativa neste processo na quantidade testada (1% mol da quantidade de Ca(HCO3)2). Quanto ao processo de permuta iónica, os resultados obtidos permitiram concluir que a razão líquido-sólido (v/m) ótima foi de 200. Os modelos de equilíbrio que representaram melhor o processo de permuta iónica foram o modelo de Langmuir para T=20ºC, obtendo-se uma capacidade total de permuta iónica de 416,67 mg g-1 de resina seca, e o modelo de Temkin para T=30ºC. Relativamente aos modelos cinéticos, o que apresentou melhor ajuste aos dados experimentais foi o modelo de pseudo-primeira ordem. Assim, concluiu-se que a superfície da resina é homogénea e que o processo de permuta iónica é reversível, sendo a sua cinética diretamente proporcional à capacidade do sólido. O estudo da etapa de regeneração permitiu verificar que é possível reutilizar a resina estudada. No que diz respeito à operação em leito fixo, os resultados experimentais indicaram que o tempo estequiométrico foi atingido aos 153 minutos e que a resina ficou saturada aos 259 minutos, devendo o processo ser interrompido aos 65 minutos. O amaciamento da água permitirá uma redução de custos em relação ao plano de higienização da Goanvi que é atualmente praticado. O reaproveitamento das águas de enxaguamento bem como do Nifos 10 (descalcificante) presente nestas é uma mais-valia quer ao nível da redução de custos quer ao nível ambiental. Face aos resultados alcançados, pode-se concluir que o processo de permuta iónica é o mais promissor ao nível de redução da dureza da água uma vez que dos processos estudados é o mais eficiente.
In the scope of the course Dissertation of the Master in Chemical Engineering of University of Coimbra, it become possible to accomplish this work in the Goanvi – Central de Engarrafamento de Bebidas, adopting the theme "Analysis and Optimization of the Washing Process of a Beverage Bottling Plant”. More specifically, this work involved the study of water softening by chemical precipitation and ion exchange as well as the economic analysis regarding the consumption of cleaning products. In the study of the chemical precipitation process, the analysis of the effect of the amount of Ca(OH)2 added to the water sample and the effect of the addition of coagulant were studied. In the ion exchange process, the equilibrium and batch kinetics were also accessed using the cationic resin Amberlite IR-120 Na+. Fixed bed operation and batch regeneration process were also evaluated. The experimental results indicated that it is possible to reduce the water hardness to a value of 100 mg L-1 CaCO3 by chemical precipitation and the addition of 1% mol (relatively to the amount of Ca(HCO3)2) coagulant has no significant influence in this process. Regarding the ion exchange process, the results allowed to obtain as optimum liquid-solid ratio (v/wt) of 200. The equilibrium models that best represent the ion exchange process were the Langmuir model, for T = 20°C, where the total ion exchange capacity was 416.67 mg g-1 of dry resin, and the Temkin model for T = 30°C. In the kinetic models, the best fit to the experimental data was the pseudo-first order model. Thus, it is concluded that the resin surface is homogeneous and the ion exchange process is reversible. Also, the kinetic is directly proportional to the solid capacity. The study of the regeneration step showed that it is possible to reuse the resin studied in this work. Considering the fixed bed operation, the experimental results herein obtained indicate that the stoichiometric time and the resin saturation are reached at 153 minutes and 259 minutes, respectively. Consequently, the process must be stopped at 65 minutes. The water softening allows a cost reduction in the hygienization plan already used in Goanvi. The reuse of rinse water and Nifos 10 therein present can be an important value in the terms of cost reduction and also at an environmental level. Concerning all results obtained, it is possible to conclude that the ion exchange process is the most promising in terms of water hardness reduction, since it is the most efficient compared to the all studied processes.
APA, Harvard, Vancouver, ISO, and other styles
48

Campos, Bruno Filipe de Castro. "Estágio na empresa Captágua: dimensionamento e execução de captações de águas subterrâneas." Master's thesis, 2019. http://hdl.handle.net/10773/29512.

Full text
Abstract:
Com o aumento das necessidades hídricas da população é de grande importância recorrer a alternativas de captação de água. A água subterrânea, para além de apresentar uma menor suscetibilidade à poluição, também apresenta variações de nível mínimas, comparativamente à água superficial, sendo por isso uma boa alternativa. O presente trabalho, que visa descrever o trabalho realizado, durante um semestre de estágio na empresa Captágua – Captações de água, Lda., pretende apresentar os processos associados à construção de uma captação de água subterrânea. É de igual importância as fases preparatórias de um furo, bem com a manutenção do mesmo. Com base no acompanhamento de obras, proporcionado pela empresa, foi possível adquirir conhecimentos relevantes relativamente aos métodos de perfuração e ferramentas a utilizar, assim como na colocação da coluna de revestimento e do material de preenchimento do espaço anelar. O conhecimento dos procedimentos associados à limpeza da captação assim como os associados aos ensaios de caudal é também essencial para uma exploração sustentável de uma captação. Nesse sentido a empresa proporcionou também o acompanhamento da realização desses ensaios, quer após a conclusão da construção do furo, quer em situações anómalas. Como complemento é apresentado neste trabalho um caso de estudo referente a uma perfuração e também um ensaio de caudal realizado noutra captação, antes da colocação definitiva do equipamento de bombagem.
With the increasing water need of the population, it is very important to use water abstraction alternatives. Groundwater compared to surface water, is less susceptible to pollution and it presents annual minimal water level variation, being considered as a good alternative. This work, which describes the work performed during 6 month in Captágua – Captações de Água, Lda., and aims to present the processes involving the construction of groundwater boreholes. Equally, importance is given to the preparatory phases of a borehole as well as it maintenance. Based on the fieldwork monitoring, provided by the company, it was possible to acquire relevant knowledge about the drilling methods and tools used, as well as the placement of casing, gravel and sealing application. Development and pump testing are essential for a sustainable exploitation of a borehole, and therefore implemented, either after the construction of the borehole or in anomalous situations. In addition, in this work, the author presents a case study regarding a drilling of a borehole for groundwater supply and another case study showing a flow test performed in other borehole before the design and installation of the pumping equipment.
Mestrado em Geomateriais e Recursos Geológicos
APA, Harvard, Vancouver, ISO, and other styles
49

Muller, Leandro. "Uso eficiente da água em zonas urbanas: otimização da pegada hídrica." Master's thesis, 2019. http://hdl.handle.net/10400.1/13665.

Full text
Abstract:
O crescimento demográfico das últimas décadas, principalmente nas áreas urbanas, e os atuais estilos de vida, têm levado a consumos de água cada vez maiores e com usos mais diversos. Os recursos hídricos nunca sofreram tanta pressão antrópica. A procura de novas origens de água e o seu uso eficiente são imperativos, e o cidadão comum deve ser consciencializado da importância das suas ações diárias. O conceito da Pegada Hídrica pode servir de instrumento para mostrar à população a quantidade de água que utiliza no seu dia a dia, de forma pouco eficiente. Os mais jovens, atraídos pelas novas tecnologias de comunicação, estarão fortemente recetivos à utilização de novas tecnologias de informação e comunicação, neste caso, para o cálculo da sua Pegada Hídrica. O Projeto ECH2O - ÁGUA procura contribuir para o uso eficiente da água, utilizando uma Comunidade Experimental, envolvendo atores de várias faixas etárias e profissões, em escolas, lares de idosos e residências habitacionais. Foi feito um reconhecimento de cada Comunidade Experimental e instalados dispositivos de redução de caudal em autoclismos, chuveiros e torneiras. Verificou-se que considerando o valor aferido para a Pegada Hídrica – Consumo Direto é 216 ±92 L, cerca de dez vezes menor do que o Consumo Indireto. A quantidade de água poupada com a instalação dos redutores de caudal, pode corresponder a um volume muito significativo, sobretudo em cenários de escassez. Conseguiram-se reduções médias de caudal de 29 % nos autoclismos, 44 % nos chuveiros e 45 % nas torneiras. Disponibilizou-se online um formulário para o cálculo da Pegada Hídrica, para funcionar como ferramenta de alerta para os desperdícios de água e para a necessidade da sua poupança. A Pegada Hídrica calculada com base nos 193 inquéritos preenchidos e validados foi similar a outras obtidas anteriormente em Portugal e noutros países. Fizeram-se várias sessões públicas de divulgação do ECH2O – ÁGUA durante o período da sua execução. Na fase final implementou-se um website responsivo, que passou a permitir o cálculo imediato da Pegada Hídrica, para divulgação de ideias chave sobre o uso eficiente da água
During the last decades the demographic growth, especially in urban areas, and the lifestyle, increased the water consumption and diversified the uses. Water resources have never been so pressed by anthropogenic activities. The search for new water sources and the practices of efficient use are imperative. The common people should believe in the importance of their daily actions. The concept of Water Footprint can be used as a tool to show how we can save water in our daily actions. Young people, attracted by new communication technologies, will be strongly receptive to the use of new electronic tools, in this case to calculate the Water Footprint. The ECH2O - ÁGUA Project seeks to contribute to the efficient use of water, using an Experimental Community, involving of various age groups of persons with different professions, in schools, nursing homes and residences. It was characterized each Experimental Community and installed flow reduction devices in flush toilets, showers and taps. According the results of this study the Water Footprint - Direct Consumption is about 216 ± 92 L, ten times lower than Indirect Consumption. After the installation of the flow reduction devices, the amount of water saved can correspond to a very significant volume, especially in scarcity scenarios. Average flow reductions of 29 % were achieved in flush toilets, 44 % in showers and 45 % in taps. A Water Footprint calculation form is available online to act as a warning tool for water waste and to the need for water savings. The Water Footprint calculated based on the 193 completed and validated surveys was, similar to others previously obtained in Portugal and in other countries. Several ECH2O - ÁGUA public dissemination sessions were held during the Project period. To disseminate key ideas on the water efficient use, in the last phase of the ECH2O - ÁGUA, was implemented a responsive website, allowing the immediate calculation of the Water Footprint.
APA, Harvard, Vancouver, ISO, and other styles
50

Santos, Samuel Franco Rodrigues. "Contribuição para o estudo da otimização da operação de lavagem dos filtros da ETA de Monte Novo." Master's thesis, 2017. http://hdl.handle.net/10362/23044.

Full text
Abstract:
A presente dissertação centrou-se no estudo da otimização da lavagem dos filtros da estação de tratamento de água de Monte Novo, com o objetivo de contribuir para a redução dos consumos energéticos e do volume de água necessário nesta operação. Estudou-se em detalhe as caraterísticas da água ao longo da linha tratamento, principalmente a montante e jusante do sistema de filtração instalado, tendo-se avaliado a possibilidades de alteração do método de lavagem em vigor, garantindo sempre os parâmetros de qualidade legislados. Do estudo realizado conclui-se que um dos métodos de lavagem avaliados, que inclui um total de três etapas, de 3 minutos cada, sendo a primeira efetuada exclusivamente com ar, a segunda com ar e água e a terceira apenas com água, poderá ser uma alternativa ao método atualmente utilizado. Este método não compromete a qualidade da água filtrada e permite reduzir o volume de água utilizado nesta operação, em cerca de 22,6%, reduzindo igualmente os consumos energéticos na ordem dos 20%.
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!

To the bibliography