Contents
Academic literature on the topic 'Cavité optique de haute finesse'
Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles
Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Cavité optique de haute finesse.'
Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.
You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.
Journal articles on the topic "Cavité optique de haute finesse"
Heidmann, A., P. F. Cohadon, and M. Pinard. "Bruit thermique et effets quantiques dans une cavité optique de grande finesse." Le Journal de Physique IV 10, PR8 (May 2000): Pr8–19. http://dx.doi.org/10.1051/jp4:2000803.
Full textCaniard, T., T. Briant, A. Heidmann, and M. Pinard. "Bruit thermique et effets quantiques dans une cavité optique de grande finesse." Journal de Physique IV (Proceedings) 135, no. 1 (October 2006): 111–12. http://dx.doi.org/10.1051/jp4:2006135020.
Full textDissertations / Theses on the topic "Cavité optique de haute finesse"
Triki, Meriam. "Cavités optiques de haute finesse pour la mesure de composés à l'état de trace en phase gazeuse." Phd thesis, Université Joseph Fourier (Grenoble), 2008. http://tel.archives-ouvertes.fr/tel-00331642.
Full textD'abord, les notions nécessaires à la compréhension des techniques considérées sont présentées. Suit la description du développement d'un système IBB-CEAS avec une source LED émettant autour de 643 nm, avec application à la détection des oxydes d'azote à l'état de traces. Les résultats obtenus mettent en avant les avantages de cette technique en termes de simplicité, robustesse et de compacité. La limite de détection obtenue pour le radical NO2 est estimée à 1 ppbv pour deux minutes de temps d'acquisition.
Pour la deuxième étude concernant une source laser de type VECSEL émettant à 2.3 μm et pompé optiquement, le résultat principal a été l'obtention d'un balayage monofréquence sur une grande plage spectrale de l'ordre de 16.5 cm-1. Cela a demandé un balayage simultané de la température et de la longueur de la cavité laser. Ensuite, des essais préliminaires on été effectués pour coupler cette source avec la technique OF-CEAS. Ces essais ont révélé un problème de stabilité du comportement monofréquence de la source VECSEL en présence de rétroaction optique.
Enfin, la faisabilité de la technique OF-CEAS avec une source ECDL émettant dans l'infrarouge proche pour le diagnostic des décharges à basse pression a été démontrée. Le coefficient d'absorption minimale obtenu est de l'ordre de 10-9 cm-1 pour un temps d'acquisition court (0.1 s), valeur typique atteinte auparavant dans divers systèmes OF-CEAS. Des essais ont été réalisés avec une décharge en flux d'argon avec des traces de méthane autour de 1 mbar. Le même niveau de bruit a été observé que sans décharge. Cependant, dans la gamme spectrale accessible avec le ECDL disponible, les radicaux de type CHX produits dans ce type de décharge n'ont pas été détectés.
Cantin, Etienne. "Cavité à haute finesse pour la production et la détection de sources atomiques cohérentes." Thesis, Bordeaux, 2015. http://www.theses.fr/2015BORD0259/document.
Full textThis thesis reports the development of two original tools for atom interferometry.The first is a high finesse optical cavity for the manipulation of 87Rb cold atoms. This cavity isfirstly used to enhance the intensity of an optical dipole trap. Thus, by realizing an evaporativecooling on the atomic sample, we reached Bose-Einstein condensation. Furthermore, the nondegeneratecavity allows the injection of different transverse electromagnetic modes. In thisway, we have demonstrated the generation and the manipulation of arrays of atomic ensemblesusing these modes. Successive measurements of these atomic ensembles in an atominterferometric sequence would increase the interrogation time and thus the sensitivity of thesensor.Secondly, the use of weak nondestructive measurements on the atoms allows to extractinformation from the system with negligible perturbation of the ensemble. Applying feedbackafter the measurement, we were able to control the quantum state of the system. Using amodified Ramsey sequence with weak nondestructive measurements and phase corrections, werealized a phase lock loop between a local oscillator and the atomic state. We have thendemonstrated that this protocol leads to a stability enhancement of an atomic clock byovercoming the limit set by the local oscillator.We also contributed to the development of the commercial laser platform EYLSA fromQuantel, testing its performances on two laser cooling experiments
Favier, Pierre. "Etude et conception d'une cavité Fabry-Perot de haute finesse pour la source compacte de rayons X ThomX." Thesis, Université Paris-Saclay (ComUE), 2017. http://www.theses.fr/2017SACLS412/document.
Full textInverse Compton Scattering provides a unique way to produce quasi-monochromatic X-rays via the interaction of relativistic electrons with a laser pulse. This process has the advantage of producing very high fluxes of X-rays with energies above a few tens of keV. In addition the output beam divergence is much larger than in classical synchrotron light sources and the X-ray beam is thus easier to manipulate. We present an X-ray source under construction at Paris-Sud University, ThomX. This source uses a 50 MeV electron beam that collides at 16.7 MHz with a few picoseconds pulsed laser beam whose power is enhanced at the state of the art 600 kW average power to produce X-rays between 30 and 50 keV with a flux of 10^{13} ph/s. This energy range as well as the energy-angular dependence coming from the physical process are suitable for societal applications like radiotherapy or art history.A very high finesse optical cavity (> 24000) is used as a prototype to perform R&D for the ThomX source. 400 kW of average laser power have been successfully stored in this cavity, using an input laser beam of only 40 W. This result, unique in the world, is a pathway towards the completion of the low-cost, compact, high flux X-ray source ThomX. This thesis explains the experimental and analytical studies that have been performed to reach this performance, including a generalization of the process of laser pulse stacking to frequency-detuned laser beams, and the methods developped for experimental spatial coupling enhancement
Vanderbruggen, Thomas. "Détection non-destructive pour l'interférométrie atomique et Condensation de Bose-Einstein dans une cavité optique de haute finesse." Phd thesis, Université Paris Sud - Paris XI, 2012. http://tel.archives-ouvertes.fr/tel-00702905.
Full textVanderbruggen, Thomas. "Détection non-destructive pour l’interférométrie atomique et Condensation de Bose-Einstein dans une cavité optique de haute finesse." Thesis, Paris 11, 2012. http://www.theses.fr/2012PA112067/document.
Full textIn this thesis, we study several methods to improve atom interferometers. In the first part of the manuscript, we analyze how a nondestructive detection, that preserves the coherence between the internal degrees of freedom in an atomic ensemble, can be used to increase the sensitivity of interferometers. We first theoretically show how the projection of the wave-function induced by the measurement prepares spin-squeezed states. We then present the implementation of this method with a detection based on the frequency modulation spectroscopy. Finally, some first applications are described, more explicitly we show how to implement a quantum feedback that preserve the atomic state against the decoherence induced by a random collective flip, we also introduce a phase-locked loop where the atomic sample is used as the phase reference. In the second part of the manuscript, we present the all-optical realization of a Bose-Einstein condensate in a high-finesse cavity using a laser system based on standard telecoms technologies. We first describe the resonator and the frequency lock of the laser on the resonance, in particular, we introduce a new stabilization method based of the serrodyne modulation. Finally, we show how the condensate is obtained from the evaporation in the cavity mode
Bernon, Simon. "Piégeage et mesure non-destructive d'atomes froids dans une cavité en anneau de haute finesse." Palaiseau, Ecole polytechnique, 2011. https://theses.hal.science/docs/00/62/46/68/PDF/Manuscript_totalV2.pdf.
Full textThis thesis investigates the generation of atomic spin-squeezed states by quantum non-demolition (QND) measurements in a high-finesse optical cavity. Cold atom interferometry has demonstrated state of the art performance for the measurement of tiny rotations, accelerations and time. The sensitivity of atom interferometers has already reached the atomic shot noise level, a limit that could be overcome by the use of non-classical atomic states. In this context, we developed a crossed high-finesse cavity resonating both at 1560 nm and 780 nm. Laser light at 1560 nm injected in the cavity generates a far off resonance optical dipole trap where Rb 87 cold atoms are loaded from a magneto-optical trap. The lifetime of the atoms in this dipole trap is limited by the residual background collisions, indicating that further evaporation process should be effective. The concepts of QND measurement are introduced and a wavefunction formalism that describes the spin-squeezing dynamics of the atomic state is discussed. This formalism is applied to practical measurement apparatus that are the Mach-Zehnder interferometer and the heterodyne detection. Experimentally, this non-destructive measurement was implemented at 780 nm in a frequency modulation scheme strongly immune to noise. The influence of this non-demolition probe on the atomic sample has been characterized in single pass and this tool has been applied to follow in real time the state of atomic interferometers. In addition to this work, a narrow linewidth Raman laser suitable for high precision spectroscopy was implemented with cold atoms as the gain medium
Morville, Jérôme. "Injection des cavités optiques de haute finesse par laser à diode : application à la CW-CRDS et à la détection de traces atmosphériques." Université Joseph Fourier (Grenoble), 2001. http://www.theses.fr/2001GRE10092.
Full textThiébaud, Jérôme. "Développement d'un spectromètre à cavité optique de haute finesse couplé à la photolyse laser : mesures spectroscopiques et cinétiques du radical HO2." Lille 1, 2007. https://pepite-depot.univ-lille.fr/LIBRE/Th_Num/2007/50376-2007-Thiebaud.pdf.
Full textMotto-Ros, Vincent. "Cavités de haute finesse pour la spectroscopie d'absorption haute sensibilité et haute précision : Application à l'étude de molécules d'intérêt atmosphérique." Phd thesis, Université Claude Bernard - Lyon I, 2005. http://tel.archives-ouvertes.fr/tel-00011763.
Full textTout d'abord, la technique CW-CRDS (Continuous Wave – Cavity Ring Down Spectroscopie) est utilisée pour étudier l'évolution avec la pression et la température des spectres atmosphériques de la vapeur d'eau dans le proche infrarouge. Cette étude, destinée à calibrer des mesures d'absorption différentielle par Lidar, entre dans le cadre de la mission WALES (Water Vapour Lidar Experiment in Space) proposée par l'Agence Spatiale Européenne. Une attention particulière est portée pour décrire et caractériser le système expérimental.
Ensuite, la technique OF-CEAS (Optical Feedback Cavity Enhanced Absorption Spectroscopy) et ses performances pour la spectroscopie sont mises en évidence avec l'étude de la bande B de l'oxygène dans le rouge. Cette technique repose sur un schéma d'injection avec rétroaction optique (de la cavité vers le laser) qui permet d'augmenter la cohérence de son émission pour mesurer les maxima de transmission des modes même avec des cavités de haute finesse. Une configuration nouvelle permettant ces effets est proposée (la cavité Brewster). Une gamme dynamique sur la mesure d'absorption d'environ cinq ordres de grandeurs est démontrée (1e-5 à 1e-10 /cm) ainsi qu'une sensibilité < 1e-10 /cm/Hz^(1/2). Un schéma d'acquisition mode par mode est employé et permet d'exploiter la linéarité du peigne de mode pour atteindre des hautes précisions sur la fréquence. La pertinence de cette approche est mise en évidence par la mesure de « pressure shifts » de l'oxygène obtenus avec une précision absolue record inférieure à 5*1e-5 cm^(-1)/atm.
Cermak, Peter. "Spectroscopie optique de haute sensibilité dans les plasmas et les gazes." Phd thesis, Université de Grenoble, 2010. http://tel.archives-ouvertes.fr/tel-00564511.
Full text