To see the other types of publications on this topic, follow the link: Chromatographic detectors.

Dissertations / Theses on the topic 'Chromatographic detectors'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 50 dissertations / theses for your research on the topic 'Chromatographic detectors.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.

1

McBrady, Adam Dewey. "Microfabricated chromatographic instrumentation for micro total analysis systems /." Thesis, Connect to this title online; UW restricted, 2006. http://hdl.handle.net/1773/8570.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Brückner, Carsten Albrecht. "Rapid chromatographic analysis using novel detection systems and chemometric techniques /." Thesis, Connect to this title online; UW restricted, 1998. http://hdl.handle.net/1773/11573.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Foster, Marc Douglas. "Liquid chromatographic separation and sensing principles with a water only mobile phase /." Thesis, Connect to this title online; UW restricted, 1996. http://hdl.handle.net/1773/8503.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Kim, Byungchul. "Analysis of Melamine and Cyanuric Acid by Liquid Chromatography with Diode Array Detection and Tandem Mass Spectrometry." Fogler Library, University of Maine, 2009. http://www.library.umaine.edu/theses/pdf/KimB2009.pdf.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Qian, Zheng Ming. "Analysis of components in water extract of ten valued traditional Chinese medicines using liquid chromatography system with multiple columns and detectors." Thesis, University of Macau, 2012. http://umaclib3.umac.mo/record=b2590375.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Viljoen, Francois Petrus. "Quantification of 3-methoxy-4-hydroxyphenylglycol in human saliva by an optimised HPLC method with electrochemical detection." Thesis, Bloemfontein : Central University of Technology, Free State, 2011. http://hdl.handle.net/11462/17.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Motley, Curtis Bobby. "The evaluation of an argon and helium highly efficient microwave induced plasma as an element selective detector for packed column super critical fluid chromatography." Diss., Virginia Tech, 1990. http://hdl.handle.net/10919/37740.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Sreedharan, Nair Shree Narayanan. "MicroGC: Of Detectors and their Integration." Diss., Virginia Tech, 2014. http://hdl.handle.net/10919/47785.

Full text
Abstract:
Gaseous phase is a critical state of matter around us. It mediates between the solid crust on earth and inter-stellar vacuum. Apart from the atmosphere surrounding us where compounds are present, natively, in a gaseous phase, they are also trapped within soil and dissolved in oceanic water. Further, those that are less volatile do enter the gaseous phase at high temperatures. It is this gaseous phase that we inhale every second. It is thus critical that we possess the tools to analyze a mixture of gaseous compounds. One such method is to separate the components in time and then identify, prima
APA, Harvard, Vancouver, ISO, and other styles
9

Akbar, Muhammad. "Chip-Scale Gas Chromatography." Diss., Virginia Tech, 2015. http://hdl.handle.net/10919/56566.

Full text
Abstract:
Instrument miniaturization is led by the desire to perform rapid diagnosis in remote areas with high throughput and low cost. In addition, miniaturized instruments hold the promise of consuming small sample volumes and are thus less prone to cross-contamination. Gas chromatography (GC) is the leading analytical instrument for the analysis of volatile organic compounds (VOCs). Due to its wide-ranging applications, it has received great attention both from industrial sectors and scientific communities. Recently, numerous research efforts have benefited from the advancements in micro-electromecha
APA, Harvard, Vancouver, ISO, and other styles
10

Huang, Degui. "Development of a capacitively coupled plasma as a gas chromatographic detector." Thesis, University of British Columbia, 1991. http://hdl.handle.net/2429/29879.

Full text
Abstract:
This work has two objectives: first, to develop an atmospheric pressure radio frequency capacitively coupled plasma (CCP) as a detector for gas chromatography (GC) and, secondly, to understand the excitation process in the CCP from a fundamental point of view. In the process of developing the CCP as a gas chromatographic detector, the design of a CCP torch useful as an atomic emission detector for GC has involved several stages of evolution. Initially, two plasma torches, a cylindrical one with concentric electrodes and a rectangular one with two parallel electrodes, were designed and their p
APA, Harvard, Vancouver, ISO, and other styles
11

Mew, Christopher Derwent. "A prototype multiplexed UV absorbance detector for high performance liquid chromatography." Thesis, King's College London (University of London), 1999. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.324979.

Full text
APA, Harvard, Vancouver, ISO, and other styles
12

Narine, Raymond. "A novel microcomputer-controlled transport detector for high-performance liquid chromatography." Thesis, King's College London (University of London), 1995. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.281718.

Full text
APA, Harvard, Vancouver, ISO, and other styles
13

Miller, Keith Edward. "Dynamic surface tension detector in flow injection analysis and liquid chromatography /." Thesis, Connect to this title online; UW restricted, 2000. http://hdl.handle.net/1773/8506.

Full text
APA, Harvard, Vancouver, ISO, and other styles
14

Zheng, Jun. "Supercritical Fluid Chromatography of Ionic Compounds." Diss., Virginia Tech, 2005. http://hdl.handle.net/10919/29519.

Full text
Abstract:
Addition of a small amount of polar solvent (i.e. modifier) which contains an ionic component (i.e. additive) to a CO2 mobile phase has shown major improvement in the elution of ionic analytes via packed column supercritical fluid chromatography (SFC). Firstly, we focused on the elution of sodium arylsulfonate analytes by using various ionic additives, such as lithium acetate, ammonium acetate, tetramethylammonium acetate, tetrabutylammonium acetate, and ammonium chloride. The analytes were successfully eluted with all additives with good peak shape under isocratic/isobaric/isothermal conditi
APA, Harvard, Vancouver, ISO, and other styles
15

Roush, John Albert. "Development and characterization of novel detectors for use in flow injection analysis or liquid chromatography." Diss., This resource online, 1992. http://scholar.lib.vt.edu/theses/available/etd-06062008-170645/.

Full text
APA, Harvard, Vancouver, ISO, and other styles
16

Ogburn, Evan T. "Characterization of a Microfabricated Electrochemical Detector and Coupling with High Performance Liquid Chromatography." University of Cincinnati / OhioLINK, 2009. http://rave.ohiolink.edu/etdc/view?acc_num=ucin1258475031.

Full text
APA, Harvard, Vancouver, ISO, and other styles
17

Cook, Daniel W. "Chemometric Curve Resolution for Quantitative Liquid Chromatographic Analysis." VCU Scholars Compass, 2016. http://scholarscompass.vcu.edu/etd/4362.

Full text
Abstract:
In chemical analyses, it is crucial to distinguish between chemical species. This is often accomplished via chromatographic separations. These separations are often pushed to their limits in terms of the number of analytes that can be sufficiently resolved from one another, particularly when a quantitative analysis of these compounds is needed. Very often, complicated methods or new technology is required to provide adequate separation of samples arising from a variety of fields such as metabolomics, environmental science, food analysis, etc. An often overlooked means for improving analysis is
APA, Harvard, Vancouver, ISO, and other styles
18

Prasad, Aditya Shankar. "Mechanical design of optics bench for UV-LED based liquid chromatography detector." Thesis, Massachusetts Institute of Technology, 2015. http://hdl.handle.net/1721.1/101818.

Full text
Abstract:
Thesis: M. Eng. in Manufacturing, Massachusetts Institute of Technology, Department of Mechanical Engineering, 2015.<br>Cataloged from PDF version of thesis.<br>Includes bibliographical references (pages 102-103).<br>The proposal for a new detector for liquid chromatography instruments that uses Ultraviolet Light Emitting Diodes (UV-LEDs) as the light source as opposed to currently used deuterium lamps required new design of the mechanical and structural components associated with it. The optics bench assembly is the heart of the detector system on which the detector optical components are mou
APA, Harvard, Vancouver, ISO, and other styles
19

Ware, Margaret LaVerne. "The Development and Application of a Helium Discharge Detector for Gas Chromatography." W&M ScholarWorks, 1988. https://scholarworks.wm.edu/etd/1539625431.

Full text
APA, Harvard, Vancouver, ISO, and other styles
20

Forzy, Gérard. "Les detecteurs electrochimiques en chromatographie liquide a haute pression : caracteristique, evaluation, optimisation." Lille 2, 1990. http://www.theses.fr/1990LIL2P262.

Full text
APA, Harvard, Vancouver, ISO, and other styles
21

Pannell, Daniel K. (Daniel Kirk). "Detector Comparison for Simultaneous Determination of Organic Acids and Inorganic Anions." Thesis, University of North Texas, 1988. https://digital.library.unt.edu/ark:/67531/metadc500456/.

Full text
Abstract:
The research reported here is a study of detector systems to determine those most suited for simultaneous organic acid, inorganic anion determination. Comparisons are made on the basis of detection limits and sensitivities for conductivity, UV/Vis, photoconductivity, and derivative conductivity detection systems. The investigation was made using a constant chromatographic system with the only variable component being the detector system. Eluant optimization conditions for each detector are reported along with tables reporting detection limits and sensitivities for each detector system. Various
APA, Harvard, Vancouver, ISO, and other styles
22

Schofield, Paul Anthony. "An investigation of the response mechanism of the nitrogen phosphorus detector." Thesis, Manchester Metropolitan University, 1999. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.300730.

Full text
Abstract:
The Nitrogen Phosphorus Detector is a sensitive, selective device used in gas chromatography. It responds selectively towards nitrogen and phosphorus containing organic compounds with detection limits in the picogram range. The detector is of great importance for the measurement of trace levels of drugs, pesticides and herbicides in biological matrices and the environment. There is, however, some dispute in the literature regarding the detector's response mechanism. The detector is based on a hydrogen-air diffusion flame. Two electrodes polarise the flame with a potential difference of about 2
APA, Harvard, Vancouver, ISO, and other styles
23

Saxena, Saksham. "Development of a product architecture for a LED based detector for liquid chromatography." Thesis, Massachusetts Institute of Technology, 2015. http://hdl.handle.net/1721.1/101817.

Full text
Abstract:
Thesis: M. Eng. in Manufacturing, Massachusetts Institute of Technology, Department of Mechanical Engineering, 2015.<br>Cataloged from PDF version of thesis.<br>Includes bibliographical references (pages 68-69).<br>This thesis develops and describes the product architecture for a LED based detector for liquid chromatography systems. The product architecture development is discussed using a customized methodology, incorporating elements from different views on product architecture development. The market scope and segmentation for such a device was studied and the effect of technologies for suc
APA, Harvard, Vancouver, ISO, and other styles
24

COSTA, JUNIOR NELSON V. da. "Caracterizacao e otimizacao analitica na determinacao de trialometanos em aguas potaveis por purga e armadilha acoplada a cromatografia a gas." reponame:Repositório Institucional do IPEN, 2010. http://repositorio.ipen.br:8080/xmlui/handle/123456789/9521.

Full text
Abstract:
Made available in DSpace on 2014-10-09T12:27:35Z (GMT). No. of bitstreams: 0<br>Made available in DSpace on 2014-10-09T14:07:31Z (GMT). No. of bitstreams: 0<br>Dissertacao (Mestrado)<br>IPEN/D<br>Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
APA, Harvard, Vancouver, ISO, and other styles
25

Liang, Yuanling. "Utilization of a scientifically operated charge-coupled device detector for high-performance thin-layer chromatographic analysis." Diss., The University of Arizona, 1998. http://hdl.handle.net/10150/282688.

Full text
Abstract:
A high-performance thin-layer chromatographic (HPTLC) separation system coupled with a scientifically operated charge-couple device detector (CCD) has been developed to improve the identification and quantitative analysis of pharmaceutical products and natural toxins. The combination of the fast, easy and high throughput properties of TLC, high speed, sensitivity, wide dynamic range of the CCD detector, and the high reproducibility and accuracy of the micro-nebulization sampler can be used to facilitate pharmaceutical industrial quality control and food industrial safety control. The applicati
APA, Harvard, Vancouver, ISO, and other styles
26

Egan, Martin Joseph. "Analysis of polyhydroxyalkaloids in plant extracts by chromatography and mass spectrometry : including sequential tandem MS." Thesis, University of Greenwich, 2000. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.324932.

Full text
APA, Harvard, Vancouver, ISO, and other styles
27

Ruellan, Jérémie. "Conception, fabrication et caractérisation d'un capteur de conductivité thermique à base de nanofils de silicium." Thesis, Université Grenoble Alpes (ComUE), 2015. http://www.theses.fr/2015GREAY025/document.

Full text
Abstract:
Les nanofils semiconducteurs sont aujourd’hui le sujet de nombreuses recherches pour leurs propriétés physiques intéressantes. S’appuyant plus spécifiquement sur les propriétés thermiques des nanostructures, l’objectif de cette thèse est de démontrer la faisabilité d’un capteur de conductivité thermique conçu à partir de nanofils de silicium pour des applications en tant que jauge Pirani ou détecteur de gaz. Le travail réalisé aborde les questions posées par la réduction de taille des objets telles que l’augmentation du bruit ou la conduction thermique en régime de raréfaction et élabore des s
APA, Harvard, Vancouver, ISO, and other styles
28

Lin, Zhong-Ping. "Gas-phase luminescence of aromatic carbonyl compounds and the design and use of a gas chromatographic detector." Thesis, National Library of Canada = Bibliothèque nationale du Canada, 1998. http://www.collectionscanada.ca/obj/s4/f2/dsk2/ftp03/NQ36559.pdf.

Full text
APA, Harvard, Vancouver, ISO, and other styles
29

Botha, Carlo Bennet [Verfasser], and M. [Akademischer Betreuer] Wilhelm. "Method Development of New Chemically Sensitive Detectors for Size Exclusion Chromatography / Carlo Bennet Botha ; Betreuer: M. Wilhelm." Karlsruhe : KIT-Bibliothek, 2021. http://d-nb.info/1230475826/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
30

Ndube, Ncediwe. "Determination of fumonisins in maize by High Performance Liquid Chromatography with fluorescence and ultraviolet detection of o-phthaldialdehyde, naphthalene-2,3-dicarboxaldehyde and dansyl chloride derivatives." Thesis, University of the Western Cape, 2011. http://etd.uwc.ac.za/index.php?module=etd&action=viewtitle&id=gen8Srv25Nme4_2588_1320667169.

Full text
Abstract:
Fumonisins, carcinogenic mycotoxins produced by various Fusarium species, occur naturally in maize and maize-based food products. They are hazards for animal and human health as they cause cancer in rodents and have been associated with oesophageal cancer and neural tube defects in humans. The most abundant naturally occurring fumonisins analogues in maize are fumonisin B1, B2 and B3 (FB1, FB2 and FB3). For analytical determination, they mostly require suitable extraction, clean-up and pre or post-column derivatization together with reversed-phase HPLC separation. o- Phthaldialdehyde (OPA) had
APA, Harvard, Vancouver, ISO, and other styles
31

Gillund, Daniel P. "Light source selection and optical design of a UV absorption based detector for liquid chromatography." Thesis, Massachusetts Institute of Technology, 2015. http://hdl.handle.net/1721.1/101819.

Full text
Abstract:
Thesis: M. Eng. in Manufacturing, Massachusetts Institute of Technology, Department of Mechanical Engineering, 2015.<br>Cataloged from PDF version of thesis.<br>Includes bibliographical references (pages 48-49).<br>Traditional sources of UVC light for absorption spectroscopy are bulky, inefficient, and output tens to hundreds of watts of heat. In this paper we present the relative merits and disadvantages of using AIN based UVC emitting LEDs for absorption detection in liquid chromatography systems compared to traditional sources. We present the optical design for a detector based on a modular
APA, Harvard, Vancouver, ISO, and other styles
32

Barnes, Suzanne R. "Size Exclusion Chromatography of Poly(2-ethyl-2-oxazoline) Homopolymers and Poly(ethylene oxide)-b-Poly(2-ethyl-2-oxazoline) Copolymers." Thesis, Virginia Tech, 2014. http://hdl.handle.net/10919/24907.

Full text
Abstract:
Size exclusion chromatography is the method of choice for characterizing molecular weights and molecular weight distributions of polymers. An important advancement in SEC is multidetection SEC which includes multi-angle laser light scattering, viscometry, refractive index and UV spectroscopy to analyze block and graft copolymers as well as polymers with oligomeric molecular weights. Oligomeric molecular weights present special challenges since the light scattering and viscosity detectors are more sensitive to higher molecular weights and both detectors have low molecular weight threshold valu
APA, Harvard, Vancouver, ISO, and other styles
33

Msimanga, Huggins Zephaniah. "Data reduction of matrices from the high-performance liquid chromatography / swept-potential electrochemical detector system and their examination by the factor analysis approach." Diss., Georgia Institute of Technology, 1988. http://hdl.handle.net/1853/30256.

Full text
APA, Harvard, Vancouver, ISO, and other styles
34

LOIOLA, ELAINE C. D. "Determinacao de residuos de hexaclorociclohexano 'HCH' no soro sanguineo de trabalhadores expostos no arquivo historico de Joinville na decada de 80." reponame:Repositório Institucional do IPEN, 2007. http://repositorio.ipen.br:8080/xmlui/handle/123456789/11756.

Full text
Abstract:
Made available in DSpace on 2014-10-09T12:55:29Z (GMT). No. of bitstreams: 0<br>Made available in DSpace on 2014-10-09T14:05:58Z (GMT). No. of bitstreams: 0<br>Dissertação (Mestrado)<br>IPEN/D<br>Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
APA, Harvard, Vancouver, ISO, and other styles
35

Kang, Lee. "The application of thin film planar waveguides as a refractive index detector for microscale high performance liquid chromatography." Diss., Virginia Tech, 1991. http://hdl.handle.net/10919/39813.

Full text
Abstract:
Thin film planar waveguides were originally introduced in microwave engineering. The spectroscopist began to use such waveguides as tools to solve chemical characterization problems since Harrick and Fahrenfort introduced the Attenuated Total'Reflection (ATR) in the early 1960's. Today, planar waveguides are playing an important and ever-increasing role in modem chemistry. In this thesis, a novel design for a refractometer involving the application of a thin film planar waveguide and coupling prism was demonstrated. This device shows the feasibility of refractive index measurements in a flowin
APA, Harvard, Vancouver, ISO, and other styles
36

Janzen, Rasmus [Verfasser], and Uwe [Akademischer Betreuer] Karst. "Development of a new small-sized plasma optical emission detector for gas chromatography / Rasmus Janzen ; Betreuer: Uwe Karst." Münster : Universitäts- und Landesbibliothek Münster, 2013. http://d-nb.info/1141383055/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
37

Jadaud, Philippe. "Separation d'hydrocarbures polynucleaires aromatiques par chromatographie en phase liquide." Paris 6, 1987. http://www.theses.fr/1987PA066442.

Full text
Abstract:
Preconcentration par chromatographie par transfert de charges sur silice greffee tetrachlorophtalimidopropyle. La retention varie de 80 (fluoranthene) a 2600 (benzo(ghi)perylene). Detection spectrofluorometrique
APA, Harvard, Vancouver, ISO, and other styles
38

Ghodsian, Bahram. "Development of micromachined field ionization tips for use as an integrated gas detector in a micromachined gas chromatography system." Thesis, National Library of Canada = Bibliothèque nationale du Canada, 1998. http://www.collectionscanada.ca/obj/s4/f2/dsk2/ftp03/NQ37704.pdf.

Full text
APA, Harvard, Vancouver, ISO, and other styles
39

Ducatte, Gerald Roger. "Aspects of the microwave induced plasma as an element selective detector for supercritical fluid chromatography and supercritical fluid extraction." Diss., Virginia Tech, 1993. http://hdl.handle.net/10919/39732.

Full text
APA, Harvard, Vancouver, ISO, and other styles
40

Comiran, Eloisa. "Lisdexanfetamina : desenvolvimento e validação de métodos bioanalíticos por cromatografia líquida acoplada a detector de massas e avaliação famacocinética preliminar." reponame:Biblioteca Digital de Teses e Dissertações da UFRGS, 2015. http://hdl.handle.net/10183/148120.

Full text
Abstract:
Lisdexanfetamina (LDX) é um pró-fármaco estimulante de longa duração indicado para o tratamento dos sintomas do transtorno do déficit de atenção e hiperatividade e do transtorno da compulsão alimentar periódica. A hidrólise da ligação amida da LDX ocorre in vivo liberando a molécula terapeuticamente ativa d-anfetamina (d-ANF) e o aminoácido l-lisina. Visto que a LDX se biotransforma à d-ANF – um potente estimulante do sistema nervoso central com destaque tanto na clínica quanto na toxicologia – existe potencial para uso inadequado, abuso e desvio para fins não terapêuticos. Nos laboratórios de
APA, Harvard, Vancouver, ISO, and other styles
41

Njie, Njaw. "Use Of Multi-walled Carbon Nanotubes In Matrix Solid Phase Dispersion Extraction Combined With Gas Chromatography." Master's thesis, METU, 2008. http://etd.lib.metu.edu.tr/upload/2/12609590/index.pdf.

Full text
Abstract:
The use of Multi-Walled Carbon Nanotubes (MWCNT) as solid sorbent in Matrix Solid-Phase Dispersion (MSPD) extraction and preconcentration method was presented to determine some commonly used organophosphorus insecticides/OPIs in honey samples using a Gas Chromatography Flame Ionization Detector (GC-FID). OPIs are poisonous compounds used to kill insects and rodents by affecting their nervous system. The limit of detections obtained after MSPD extraction were 7.0 ng/g for Malathion, Malaoxon and Fenitrothion and 33.3 ng/g for Isomalathion. The recovery of the insecticides from spiked honey, ran
APA, Harvard, Vancouver, ISO, and other styles
42

Al-Harbi, Nasser Munawir D. "Characterisation of complex polymer mixtures." Thesis, University of Manchester, 2011. https://www.research.manchester.ac.uk/portal/en/theses/characterisation-of-complex-polymer-mixtures(be0269fe-2ac3-4128-ba57-4a03dbf46a7e).html.

Full text
Abstract:
The polymer of intrinsic microporosity PIM-1 was synthesized following various procedures: (i) from fluoro-monomer by the conventional method, (ii) from fluoro-monomer by a high temperature, high shear mixing method and (iii) from chloro-monomer. For a more complete understanding of the structure of the resultant products of a series of polymerizations under different reaction conditions, a multi-detector gel permeation chromatography (GPC) method was established and validated. A procedure for fractionating PIM-1 using chloroform methanol solvent mixtures was established and validated. A combi
APA, Harvard, Vancouver, ISO, and other styles
43

Bernard, Joël. "Design and characterization of a thermochemical high performance liquid chromatography flame photometric detector for the detection of non-volatile andor thermolabile sulfur compounds." Thesis, McGill University, 1999. http://digitool.Library.McGill.CA:80/R/?func=dbin-jump-full&object_id=35982.

Full text
Abstract:
The need for selective and inexpensive detectors in liquid chromatography is of considerable interest in the determination of sulfur compounds. Of the available-selective sulfur methodologies, flame photometric detector coupled to gas chromatography is the most widely used. It has proven to be a sensitive and selective method for detection of heat stable and volatile sulfur compounds. Fundamentally, this technique is not applicable to high boiling and/or thermolabile sulfur compounds. More recently, hyphenated flame photometric detector has been utilized, with limited success, to monitor sulfu
APA, Harvard, Vancouver, ISO, and other styles
44

Rivera, Vélez Sol Maiam. "Targeted carotenoid metabolite profiling in transgenic cereals and correlations with carotenoid gene expression." Doctoral thesis, Universitat de Lleida, 2012. http://hdl.handle.net/10803/96940.

Full text
Abstract:
El meu treball de recerca va consistir en la millora, desenvolupament i aplicació de tècniques analítiques per a l'anàlisi qualitatiu i quantitatiu de carotenoides en cereals, principalment en blat de moro i arròs. Inicialment vaig treballar en l'optimització del mètode d'extracció d'aquests pigments. Es compararen diferents combinacions de solvents per determinar el millor solvent extractant que permetés alliberar tots els carotenoides de la llavor de blat de moro, malgrat les seves diferents polaritats. Addicionalment, vaig millorar i desenvolupar dos mètodes cromatogràfics per HPLC i UHPLC
APA, Harvard, Vancouver, ISO, and other styles
45

OLIVEIRA, JUSTINE P. R. de. "Estudo dos poluentes orgânicos persistentes (POPS) em regiões industriais da Grande São Paulo - via cromatografia a gás acoplada a espectrometria de massas (GC-MS) e captura de elétrons (GC-ECD)." reponame:Repositório Institucional do IPEN, 2011. http://repositorio.ipen.br:8080/xmlui/handle/123456789/10186.

Full text
Abstract:
Made available in DSpace on 2014-10-09T12:35:45Z (GMT). No. of bitstreams: 0<br>Made available in DSpace on 2014-10-09T14:03:50Z (GMT). No. of bitstreams: 0<br>Dissertação (Mestrado)<br>IPEN/D<br>Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
APA, Harvard, Vancouver, ISO, and other styles
46

Dufour, Alizée. "Caractérisation des tensioactifs polydisperses industriels par spectrométrie de masse et chromatographie en phase liquide." Thesis, Université Paris sciences et lettres, 2020. http://www.theses.fr/2020UPSLS019.

Full text
Abstract:
Dans le cadre de la production pétrolière, la formulation de tensioactifs employés devient de plus en pluscomplexe, notamment pour la récupération assistée du pétrole. De ce fait des enjeux analytiquesapparaissent lors du suivi de ces tensioactifs. Suite à une caractérisation fine réalisée à l’aide de laspectrométrie de masse haute résolution (HRMS), une étude préliminaire a permis d’étudier lescomportements chromatographiques des tensioactifs sur différentes phases stationnaires. Un criblage deneuf colonnes a démontré que la séparation monodimensionnelle ne permettait pas d’obtenir uneséparat
APA, Harvard, Vancouver, ISO, and other styles
47

Stokl, Caroline. "Development of a laser-based infrared detector for high pressure liquid chromatography. The analysis of cholesterol, cholestryl esters and triglycerides in serum." Thesis, McGill University, 1987. http://digitool.Library.McGill.CA:80/R/?func=dbin-jump-full&object_id=75894.

Full text
Abstract:
An infrared detector is constructed for use in High Pressure Liquid Chromatography. The detector uses a helium-neon laser which emits at 3.39 microns in the infrared as the source and a commercial lead selenide semiconductor as the detector. The detector when used in the flow-injection analysis mode can detect all classes of lipid: fatty acids, triglycerides, phospholipids, cholesterols and cholestryl esters. Chromatography using a normal phase column with separation into the lipid classes of cholesterol, cholestryl esters and triglycerides is performed. A purchased serum sample has been prepa
APA, Harvard, Vancouver, ISO, and other styles
48

Shinde, Suhas, Shivakumar Devaiah, and Aruna Kilaru. "Profiling Abscisic Acid-Induced Changes in Fatty Acid Composition in Mosses." Digital Commons @ East Tennessee State University, 2017. https://dc.etsu.edu/etsu-works/4745.

Full text
Abstract:
In plants, change in lipid composition is a common response to various abiotic stresses. Lipid constituents of bryophytes are of particular interest as they differ from that of flowering plants. Unlike higher plants, mosses have high content of very long-chain polyunsaturated fatty acids. Such lipids are considered to be important for survival of nonvascular plants. Here, using abscisic acid (ABA )-induced changes in lipid composition in Physcomitrella patens as an example, a protocol for total lipid extraction and quantification by gas chromatography (GC) coupled with flame ionization detecto
APA, Harvard, Vancouver, ISO, and other styles
49

Macias, Michael S. "The Development of an Optimized System of Narcotic and Explosive Contraband Mimics for Calibration and Training of Biological Detectors." FIU Digital Commons, 2009. http://digitalcommons.fiu.edu/etd/123.

Full text
Abstract:
Current commercially available mimics contain varying amounts of either the actual explosive/drug or the chemical compound of suspected interest by biological detectors. As a result, there is significant interest in determining the dominant chemical odor signatures of the mimics, often referred to as pseudos, particularly when compared to the genuine contraband material. This dissertation discusses results obtained from the analysis of drug and explosive headspace related to the odor profiles as recognized by trained detection canines. Analysis was performed through the use of headspace solid
APA, Harvard, Vancouver, ISO, and other styles
50

Horáková, Hana. "Analýza hlavních sacharidů vína." Master's thesis, Vysoké učení technické v Brně. Fakulta chemická, 2009. http://www.nusl.cz/ntk/nusl-216520.

Full text
Abstract:
This diploma thesis deals with determination of carbohydrates in wine. Theoretical part attends to production of wine from grape to treatment and training of wine. It refers saccharides in wine, especially glucose and fructose. The study provides an overview of the available sources concerning the possibilities of determination of carbohydrates in wine by chromatographic methods and Skalar automated chemistry analyser. The study shortly refers simple analytical methods for determination of wine saccharides. The experimental part based on this search deals with analysis of saccharides by high p
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!