Academic literature on the topic 'Cimento de fosfato de zinco'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Cimento de fosfato de zinco.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "Cimento de fosfato de zinco"

1

CAMPOS, Tomie Nakakuki de, Matsuyoshi MORI, Alberto Tsutomu HENMI, and Tetsuo SAITO. "Infiltração marginal de agentes cimentantes em coroas metálicas fundidas." Revista de Odontologia da Universidade de São Paulo 13, no. 4 (December 1999): 357–62. http://dx.doi.org/10.1590/s0103-06631999000400007.

Full text
Abstract:
Um dos principais objetivos do cimento, que fixa a restauração protética ao dente, é o selamento da fenda existente entre os mesmos. Para avaliar a infiltração marginal, foram feitos preparos cavitários padronizados, em 20 dentes naturais extraídos. As coroas totais foram fundidas em NiCr, sendo 10 cimentadas com cimento de fosfato de zinco e 10 com cimento resinoso Panavia 21. As amostras foram submetidas à ciclagem térmica e em seguida foram colocadas em solução de azul de metileno a 0,5%. Após o seccionamento vestíbulo-lingual, os corpos-de-prova foram examinados com lupa de aumento. Houve diferença significante entre os dois cimentos testados, sendo que 100% das amostras cimentadas com cimento de fosfato de zinco apresentaram infiltração atingindo dentina e polpa e 100% das amostras cimentadas com Panavia 21 não sofreram qualquer tipo de infiltração. Conclui-se que: o cimento resinoso Panavia 21 apresentou melhores resultados, quanto ao grau de infiltração, quando comparado com o cimento de fosfato de zinco, na cimentação de coroas metálicas fundidas em NiCr.
APA, Harvard, Vancouver, ISO, and other styles
2

Alderete Llamosa, Alfredo, André Antônio Pelegrine, Lucas Cesar Calistro, Alysson Henrique Neves Ramos, Éber Coelho Paraguassu, Ronan Vieira, Eric Janses Fernandes Tinoco, and Roberta Basting. "Tração necessária para a remoção de copings de coroa fundida cimentada em pilares de implante dentário." Brazilian Journal of Implantology and Health Sciences 2, no. 3 (March 27, 2020): 26–36. http://dx.doi.org/10.36557/2674-8169.2020v2n3p26-36.

Full text
Abstract:
Introdução: As próteses fixas implanto-suportadas são alternativas de tratamentos cada dia mais frequente nas clinicas odontológicas. Elas podem ser parafusadas ou cimentadas dependendo do planejamento cirúrgico. As próteses parafusadas são reversíveis, tem maior infiltrado bacteriano, estética prejudicada pelo orifício dos parafusos. As próteses cimentadas têm dificuldades de reversão, perda da prótese em caso de afrouxamento de parafuso e uma melhor estética por não ter orifício do parafuso. Objetivos: Nesse contexto, o presente estudo, pretender avaliar os níveis de resistência a tração dos copping´s cimentados por 2 diferentes tipos de cimentos para fixação de coroas implanto-suportadas cimentadas. Metodologia: Foram confeccionados três corpos de prova com implantes e coroas cimentadas com diferentes matérias, onde cada um desses corpos de prova foi submetido a um teste de tracionamento. Resultados: Os copping´s cimentados com cimento fosfato de zinco (CP1 e CP4) exigiram uma força de tração de 118.02 kgf e 213.63 kgf respectivamente, enquanto os copping´s cimentados com cimento resinoso (C2 e C3) exigiram uma força de tração de 258.93 kgf e 228.87 kgf respectivamente. Conclusão: Dentro das limitações das atuais condições in vitro empregadas neste estudo, a retenção de copping’s de coroa cimentada nos pilares de implantes com cimento resinoso e cimento fosfato de zinco foi significativamente afetada pelo tipo de cimento. O cimento resinoso exigiu uma força de tração significativamente maior que o cimento fosfato de zinco para a remoção dos copipng’s.
APA, Harvard, Vancouver, ISO, and other styles
3

Bohn, Priscila Veit, Daniela Guerra Andrioli, Vicente Castelo Branco Leitune, Fabrício Mezzomo Collares, Daniela Maffei Botega, Daniela Meira, Carmen Beatriz Borges Fortes, and Susana Maria Werner Samuel. "Cimentos usados em prótese fixa: uma pesquisa com especialistas em prótese de Porto Alegre." Revista da Faculdade de Odontologia de Porto Alegre 50, no. 3 (May 3, 2009): 5–9. http://dx.doi.org/10.22456/2177-0018.11243.

Full text
Abstract:
Atualmente, diversos cimentos são utilizados para cimentação de próteses fixas na prática clínica odontológica. Com o surgimento de novos materiais o cirurgião dentista assume um papel de fundamental importância na escolha do cimento empregado. O objetivo do presente estudo foi avaliar o uso de cimentos para prótese fixa por especialistas em prótese dentária que atuam no município de Porto Alegre, por meio de um questionário. Para isso, um questionário com 22 perguntas foi elaborado e aplicado a tais profissionais registrados no Conselho Regional de Odontologia. Dentre os 225 indivíduos elegíveis, 39 foram excluídos. Da amostra de 186 especialistas, 72 não foram entrevistados. Os 114 indivíduos entrevistados representaram uma taxa de resposta de 61,29%. O ano de graduação de 52% dos respondentes foi entre 1981 e 2000 e 63% concluíram o curso de pós-graduação após 1991. Para cimentação final de próteses fixas métalo-cerâmicas, 65% dos dentistas usam cimento de fosfato de zinco. Entretanto, para prótese fixas livres de metal, 57% utilizam cimento resinoso. Com o avanço da tecnologia em materiais reabilitadores, novos materiais e técnicas foram criados, no entanto, o cimento de fosfato de zinco segue como primeira escolha entre os especialistas para cimentação final de próteses métalo-cerâmicas.
APA, Harvard, Vancouver, ISO, and other styles
4

Dolfini Alexandrino, Larissa, Edwin Fernando Ruiz Contreras, Avacir Casanova Andrello, and Giovani De Oliveira Corrêa. "Evaluation of Internal Adaptation and Degree of Porosity of Total Crowns After Cementation." Journal of Health Sciences 22, no. 4 (December 21, 2020): 237–41. http://dx.doi.org/10.17921/2447-8938.2020v22n4p237-241.

Full text
Abstract:
AbstractThe present study evaluated the marginal fit, the internal filling volume and the degree of porosity in cemented metallic total crowns. Then, 12 metal crowns cast in titanium (Ti) were made on bovine teeth with total preparations and 90° shoulder terminal line. The samples were divided into 4 groups according to the type of cement used and the cementation techniques, 2 groups were used Zinc phosphate (SS White) with the partial insertion of the cementing agent filling the inner crown surface (FP) and total filling (FT), and in the other 2 groups, dual resin cement (RelyX ARC 3M) with the partial insertion of cement (RP) and total insertion (RT) were used. The results showed that cervical marginal fit after cementation was clinically adequate in all groups (<100μm), and for the internal filling volume and porosity were: FP - 99.14% / 0.86%; FT = 98.82% / 1.18%; RP - 97.06% / 2.94% and RT - 97.76% / 2.24%. The statistical analysis was performed by Mann-Whitney test. In conclusion, the two types of cements obtained acceptable values of marginal fit, however, the zinc phosphate cement had better internal fill and lower porosity than the resin cement. Regarding the insertion technique, only the FP and FT groups had a statistically significant difference (p < 0.05) compared to the RP group. Keywords: Fixed Partial Denture. X-Ray Microtomography. Dental Cements. ResumoO presente trabalho avaliou o desajuste marginal, o volume de preenchimento interno e o grau de porosidade em cimentações de coroas totais metálicas. A partir de dentes bovinos com preparos periféricos totais e términos cervicais do tipo ombro de 90º, foram confeccionadas 12 coroas metálicas fundidas em titânio (Ti). As amostras foram divididas em 4 grupos de acordo com o tipo de cimento utilizado e as técnicas de cimentação, dentre estes, em 2 grupos foram usados Fosfato de zinco (SS White) com inserção parcial do agente cimentante preenchendo a superfície interna da coroa (FP) e preenchimento total (FT), e nos outros 2 grupos foram usados Cimento resinoso dual (RelyX ARC 3M) com inserção parcial do cimento (RP) e total (RT). As análises foram feitas por microtomografia computadorizada por raios X. Os resultados mostraram que o desajuste marginal cervical após a cimentação estava adequado clinicamente em todos os grupos (<100µm), e para o volume de preenchimento interno e porosidade foram respectivamente: FP – 99,14%/0,86%; FT – 98,82%/1,18%; RP – 97,06%/2,94% e RT – 97,76%/2,24%. Na análise estatística utilizou-se o teste de Mann-Whitney para amostras independentes. Concluiu-se que os dois tipos de cimentos obtiveram valores aceitáveis de desajuste marginal, contudo o cimento de fosfato de zinco apresentou melhor preenchimento interno e menor porosidade que o cimento resinoso. Em relação à técnica de inserção, apenas os grupos FP e FT tiveram diferença estatística significativa (p<0,05) comparado ao grupo RP. Palavras-chave: Prótese Parcial Fixa. Microtomografia por Raio-X. Cimentos Dentários.
APA, Harvard, Vancouver, ISO, and other styles
5

FRANCO, Eduardo Batista, and Adriana Maria BOTELHO. "Resistência à remoção por tração de coroas totais metálicas cimentadas em dentes com e sem reconstrução coronária." Revista de Odontologia da Universidade de São Paulo 13, no. 4 (December 1999): 329–35. http://dx.doi.org/10.1590/s0103-06631999000400003.

Full text
Abstract:
O objetivo deste estudo foi verificar a resistência à remoção por tração de coroas totais metálicas cimentadas com o cimento de ionômero de vidro Ketac-Cem (ESPE) em dentes adequadamente preparados, com e sem o pré-tratamento dentinário com o ácido poliacrílico a 40%, assim como sobre dentes previamente reconstruídos com o cimento ionomérico Vitremer (3M). Para efeito de comparação, empregou-se o cimento de fosfato de zinco (SS White). Foram selecionados 50 dentes humanos (primeiros pré-molares superiores) sendo os mesmos fixados em bases cilíndricas de resina acrílica poliestirênica e divididos em 5 grupos de 10 elementos cada. Após a cimentação, os espécimes foram termociclados nas temperaturas de 5ºC, 37ºC e 55ºC e posteriormente acoplados à máquina de ensaios universal (Kratos), para a realização dos testes de resistência à tração. Os resultados obtidos foram submetidos a ANOVA, observando-se diferença estatística significante ao nível de 5% entre as diferentes condições estudadas. Com relação aos dentes sem reconstrução, verificou-se um resultado superior para o cimento Ketac-Cem quando da utilização do ácido poliacrílico. Para os grupos reconstruídos com o Vitremer, não observou-se diferença estatística significante entre os dois agentes cimentantes. A reconstrução coronária não prejudicou a retentividade das coroas totais metálicas.
APA, Harvard, Vancouver, ISO, and other styles
6

Santos, Carlos Neanes, Melissa Thiemi Kato, and Paulo César Rodrigues Conti. "Avaliação das condutas adotadas por profissionais na utilização de coroas metalo-cerâmicas." Journal of Applied Oral Science 11, no. 4 (December 2003): 290–300. http://dx.doi.org/10.1590/s1678-77572003000400004.

Full text
Abstract:
A fim de avaliar a opinião da classe odontológica sobre a utilização das coroas metalo-cerâmicas na prática odontológica, aplicou-se um questionário de 20 questões a cirurgiões-dentistas da cidade de Aracaju - SE, e a cirurgiões-dentistas e estudantes de pós-graduação em odontologia, na área de prótese dental, da cidade de Bauru-SP. Concluiu-se que: 1. As coroas metalo-cerâmicas são o tipo de restauração protética mais empregado em Odontologia. 2. A maioria dos dentistas refere-se às coroas metalo-cerâmicas como restaurações bem sucedidas, indicando superfícies oclusais metálicas para a maioria dos pacientes. 3. Apesar da maior parte dos profissionais utilizar as ligas de níquel-cromo nas coroas metalo-cerâmicas de seus pacientes, os mesmos prefeririam que ligas nobres ou semi-nobres fossem empregadas em suas próprias restaurações. 4. A maioria dos entrevistados emprega as coroas metalo-cerâmicas na restauração de dentes anteriores (57,23%). Entretanto, esse valor se deve à preferência dos dentistas de Aracaju (78%) por esse tipo de restauração, ao passo que, em Bauru, prevaleceu o número de respostas favoráveis às coroas de porcelana pura. 5. O cimento de fosfato de zinco foi o cimento de escolha da maioria dos profissionais. 6. A preferência da maior parte dos entrevistados, com relação à porcelana utilizada foi pela porcelana Vita (34,34%), em comparação às porcelanas Noritake e Dulceram Plus (13,86%). 6. Ficou evidente o desejo dos entrevistados quanto ao desenvolvimento de mecanismos que facilitem o reparo das coroas metalo-cerâmicas.
APA, Harvard, Vancouver, ISO, and other styles
7

Moraes, Paola Castro, João Guilherme Padilha Filho, Júlio Carlos Canola, Luis Alberto dos Santos, Delphin da Graça Macoris, Antônio Carlos Alessi, Márcio Botelho de Castro, and Francisco de Assis Dória Neto. "Biocompatibilidade do cimento de fosfato de cálcio implantado no rádio de coelhos." Acta Cirurgica Brasileira 19, no. 4 (August 2004): 351–59. http://dx.doi.org/10.1590/s0102-86502004000400006.

Full text
Abstract:
OBJETIVO: Avaliar a biocompatibilidade do cimento de fosfato de cálcio, para verificar sua eficácia como possível substituto ósseo. MÉTODOS: No presente trabalho, foi utilizado cimento de fosfato de cálcio em rádio de 8 coelhos, separados em dois grupos (GI e GII), referentes aos tempos de observação de 12 e 26 semanas pós-operatórias, a fim de se observar as reações entre este biomaterial e o tecido ósseo do animal. Foram feitas análises radiográficas e de densitometria óptica, além de microscopia óptica e eletrônica de varredura. RESULTADOS: Observou-se, ao final do experimento, que o cimento à base de fosfato de cálcio foi parcialmente reabsorvido durante o tempo de observação de 26 semanas, apresentando biocompatibilidade, com ausência de reações indesejáveis que pudessem ser atribuídas aos implantes. CONCLUSÕES: O cimento à base de fosfato de cálcio foi biocompatível e parcialmente reabsorvido no período de 26 semanas de observação. Tempos maiores de observação são necessários para a avaliação da reabsorção.
APA, Harvard, Vancouver, ISO, and other styles
8

Emerenciano BUENO, Carlos Roberto, Diego VALENTIM, Gustavo Sivieri ARAÚJO, Rogerio de Castilho JACINTO, João Eduardo GOMES FILHO, Luciano Tavares Angelo CINTRA, and Eloi DEZAN JUNIOR. "Estudo in vitro da influência de diferentes plugs coronários sobre o remanescente da obturação, após preparo para pino, na retenção de pinos metálicos fundidos." Dental Press Endodontics 10, no. 2 (July 1, 2020): 34–41. http://dx.doi.org/10.14436/2358-2545.10.2.034-041.oar.

Full text
Abstract:
Objetivo: Avaliar a influência de diferentes plugs de proteção, acomodados sobre o remanescente da obturação após preparo para pino, na retenção de pinos metálicos fundidos. Métodos: Cinquenta dentes bovinos foram decoronados, manualmente instrumentados até a lima manual Kerr #80 e obturados. A desobturação parcial de 10mm do conduto foi realizada com uma broca Largo e os grupos foram divididos de acordo com os diferentes materiais utilizados como plugs (n=10): Grupo I (Controle, sem plug); Grupo II (plug de Coltosol®); Grupo III (plug, em consistência de massa, de Sealapex® + óxido de zinco); Grupo IV (plug de etil-cianoacrilato); e Grupo V (plug de fosfato de zinco). Uma camada de 1mm de espessura dos diferentes plugs (Grupos II, III, IV ou V) foi acomodada sobre a obturação remanescente. Os espécimes foram selados e armazenados em 100% de umidade, por 7 dias. Após moldagem do conduto, foram confeccionados pinos metálicos fundidos e cimentados com fosfato de zinco. Os espécimes permaneceram em câmara úmida por 45 dias antes do teste de tração, realizado em uma máquina universal de ensaios. Os valores foram expressos em Mega pascal (MPa) e submetidos aos testes ANOVA e Tukey (p<0,05). Resultados: O etilcianoacrilato diminuiu a retenção dos pinos metálicos fundidos (p<0,01). Não houve diferença entre os outros grupos (p>0,05), semelhante- mente ao controle. Conclusão: A proteção da obturação com plugs confeccionados com etil-cianoacrilato prejudica a retenção de pinos metálicos fundidos cimentados com fosfato de zinco, enquanto Sealapex® acrescido de óxido de zinco, fosfato de zinco endurecido ou Coltosol® não interferem na adesividade
APA, Harvard, Vancouver, ISO, and other styles
9

Oliveira, Marilei Fátima, Henrique de Santana, Marcelo Grassi, Paulo Rogério Pinto Rodrigues, and André Lanzarin Gallina. "Estudo comparativo da fosfatização inorgânica e orgânica do aço carbono 1008 quanto à resistência a corrosão." Matéria (Rio de Janeiro) 18, no. 3 (September 2013): 1395–409. http://dx.doi.org/10.1590/s1517-70762013000300007.

Full text
Abstract:
Devido às inúmeras aplicações do aço carbono na indústria, torna-se necessária a utilização de tratamento de superfície para controle e prevenção da corrosão deste metal. Um dos sistemas utilizados como pré-tratamento do aço carbono para posterior pintura é a fosfatização à base de zinco, a qual permite melhorar a ancoragem da tinta sobre o substrato metálico. No entanto, este tratamento gera para a indústria um passivo ambiental relacionado ao lodo e ao íon metálico alergênico e poluente utilizado no processo, neste caso o Ni2+. O objetivo deste trabalho é desenvolver e caracterizar um tratamento alternativo ao fosfato de zinco para o aço carbono 1008, utilizando-se um fosfato orgânico. O método utilizado foi o de imersão do substrato metálico em uma solução aquosa de uma molécula orgânica à temperatura ambiente. Os corpos de prova do aço carbono foram avaliados utilizando-se microscopia óptica e eletrônica de varredura, espectroscopia Raman, ensaios eletroquímicos de polarização potenciodinâmica anódica e espectroscopia de impedância eletroquímica em meios ácido e neutro, além dos ensaios em Salt Spray. Os resultados eletroquímicos e de corrosão acelerada mostraram que o filme de fosfato orgânico minimiza a corrosão no aço carbono, podendo ser utilizado em substituição ao tradicional fosfato de zinco.
APA, Harvard, Vancouver, ISO, and other styles
10

Alves, Hugo Leonardo Rocha, Luis Alberto dos Santos, and Carlos Pérez Bergmann. "Influência de aditivos na injetabilidade de cimento ósseo de fosfato tricálcico." Matéria (Rio de Janeiro) 11, no. 3 (September 2006): 324–31. http://dx.doi.org/10.1590/s1517-70762006000300022.

Full text
Abstract:
Os cimentos de fosfatos de cálcio são biomateriais formados pela mistura de um pó de fosfato de cálcio com água ou com solução aquosa de sais orgânicos ou inorgânicos formando uma pasta que reage à temperatura ambiente ou corpórea, endurecendo como resultado da reação de precipitação. Cimentos de fosfato de cálcio são usados comumente em cirurgias de preenchimento ósseo na odontologia e ortopedia, que requerem procedimentos extremamente invasivos. A inovação consiste em formular uma pasta injetável pela incorporação de aditivos. Neste estudo, três aditivos (carboxi-metil-celulose, polímero de agar e alginato de sódio) foram incorporados a fosfato tricálcico-alfa, nas concentrações de 0,4%; 0,8%; 1,6%; 3,2%; 6,4% em massa. Os resultados demonstraram que foi possível obter composições de cimento de fosfato tricálcico injetáveis. Verificou-se que a injetabilidade, medida por um método inédito proposto, depende do comportamento reológico das pastas. Neste estudo, as formulações com 1,6% de carboxi-metil-celulose, 1,6% de agar e 0,8% de alginato de sódio, permitiram a obtenção de uma viscosidade suficiente para uma boa homogeneização e injeção do cimento.
APA, Harvard, Vancouver, ISO, and other styles
More sources

Dissertations / Theses on the topic "Cimento de fosfato de zinco"

1

Kon, Dino Jeiset. "\"Estudo da evolução da reação de presa do cimento de fosfato de zinco através de luz laser, aplicando a técnica óptica de speckle dinâmico\"." Universidade de São Paulo, 2006. http://www.teses.usp.br/teses/disponiveis/23/23137/tde-19032007-173211/.

Full text
Abstract:
A cimentação de próteses e/ou de outros elementos protéticos constituem-se em uma preocupação permanente, já que uma das grandes aplicações do cimento de fosfato de zinco é como agente cimentante. No entanto, a reação de presa do cimento de fosfato de zinco, assim como o tempo de sua presa final, não estão ainda completamente esclarecidos. O presente estudo visa analisar, microestruturalmente, a evolução da reação de presa do cimento de fosfato de zinco. Mais especificamente, buscou-se mensurar, baseado no fenômeno conhecido como speckle dinâmico, o tempo de duração da reação de presa do cimento de fosfato de zinco, desde o momento do término da espatulação até a sua presa completa, em ambiente com temperatura e umidade relativa do ar controlada. A metodologia utilizada consiste na análise do speckle dinâmico obtido através da luz laser, em um ensaio não-destrutivo. A partir dos dados coletados pela técnica óptica de speckle, usando algoritmos computacionais, foi possível estabelecer os coeficientes de correlação temporal e momentos de intensidade. O tratamento estatístico permitiu relacionar e comparar com outros parâmetros tradicionais, químicos e mecânicos macroestruturais já existentes e estudados por outros autores. Pode-se concluir que os resultados alcançados pela nova técnica e pelos métodos convencionais são convergentes.
The prosthesis cementation and/or other prosthetic elements, consists in permanent concern, since one of the major applications of zinc phosphate cement is as lutting agent. This study aims at the microstructural analyze to the evolution of the zinc phosphate cement´s setting reaction. More specifically, searched to verify, based on the known phenomenon as dynamic speckle, how long takes the setting reaction of zinc phosphate cement, since the moment of the ending of the mix until your complete setting, in environment with air relative humidity and temperature controlled. The used methodology consist in the analysis of dynamic speckle gotten through the laser, in a non-destructive assay. From the data supplied by the laser speckle, it was possible to establish the temporal correlation coefficients and intensity moments. The statistical treatment, allowed to compare and relate with other traditional, chemical and mechanical macrostructural parameters, already existing and studied by other authors. It can be conclude that outcomes achieved by the new technique and with the conventional methods are convergent.
APA, Harvard, Vancouver, ISO, and other styles
2

Iglésias, Michele Andréa Lopes. "Resistência à tração de retentores intra-radiculares fundidos sumetidos ao acabamento após cimentação com fosfato de zinco." Universidade Federal de Uberlândia, 2007. https://repositorio.ufu.br/handle/123456789/16856.

Full text
Abstract:
The refinement of the coronary portion of the intraradicular post cemented constitutes in routine in the clinic. However, the effects of the action of the diamond burn in high rotation on the cement agent are little argued. This study is tested the hypothesis of that the refinement with high rotation an the passed time between the cementation and the accomplishment of the refinement have negative effect in the tensile strength of the intraradicular post cemented in bovine roots. Forty eight bovine roots have been parted with 15mm of length, endodontically treated, confectioned in Cu-Al league, cemented with cement zinc phosphate and divided in 4 experimental groups (n=12). Group A: Without refinement; Group B, C e D submitted the refinement 15, 60 minutes and 24 hours respectively, after the cementation. The assay was carried through in universal machine (EMIC) with speed of 0,5mm/min for all the groups 24 hours after the cementation. The data of tensile strength had been analyzed by the analysis of the variance and test of Bartlet (α=1%). Verified that it did not have significant difference between the groups. Inside of the limitation of this study it can be concluded that the refinement with high rotation and the factor passed time between the cementation and assay did not produce effect of the resistance of the intraradicular posts.
O acabamento da porção coronária do retentor intra-radicular fundido após cimentação constitui-se rotina na clínica odontológica. Entretanto, os efeitos da ação da ponta diamantada em alta rotação sobre o agente cimentante são pouco avaliados. Este estudo testou a hipótese de que o tempo decorrido entre a cimentação e a realização do acabamento com alta rotação tenha efeito negativo na resistência à tração dos retentores intra-radiculares fundidos. Quarenta e oito raízes bovinas foram seccionadas com 15 mm de comprimento, tratadas endodonticamente e divididas aleatoriamente em quatro grupos (n=12): n=A: não submetidos ao acabamento; n=B, C e D submetidos ao acabamento com os tempos de 15, 60 minutos e 24 horas respectivamente, após a cimentação. Os condutos foram moldados pela técnica direta para a obtenção de retentores com 11 mm de comprimento intra-radicular, fundidos em cobre-alumínio, jateados com óxido de alumínio e cimentados com fosfato de zinco. O ensaio de tração foi realizado em máquina universal (EMIC) com velocidade de 0,5mm/min para todos os grupos 24 horas após a cimentação. Os resultados foram submetidos à análise de variância e teste de Bartlet (α=1%). Não houve diferenças estatisticamente significantes na resistência à tração nos grupos controle e os grupos com acabamento após a cimentação, independente do período de espera. Dentro das limitações deste estudo concluiu-se que o acabamento com alta rotação e o tempo decorrido entre a cimentação e o ensaio não produziu efeito sobre a resistência dos retentores intra-radiculares fundidos em cobre-alumínio.
Mestre em Odontologia
APA, Harvard, Vancouver, ISO, and other styles
3

Bechtold, Paola. "Avaliação in vitro da microdureza dentinária radícular em dentes bovinos após aplicação de diferentes tratamentos com hipoclorito de sódio associado ou não ao cimento de fosfato de zinco." Universidade de São Paulo, 2006. http://www.teses.usp.br/teses/disponiveis/23/23137/tde-30102006-162503/.

Full text
Abstract:
O objetivo deste estudo foi avaliar o comportamento da dentina radicular bovina frente a duas condições experimentais: a aplicação de soluções de hipoclorito de sódio nas concentrações de 0,5% e 2,5% sobre a superfície da luz radicular e a aplicação das mesmas substâncias seguida do cimento de fosfato de zinco, comparando a microdureza dentinária em duas distâncias em relação à luz do canal, nos terços radiculares. Foram utilizadas 30 raízes de incisivos superiores bovinos. Cada raiz foi seccionada em três posições: terço cervical (C), médio (M) e apical (A). Estas foram submetidas ao teste de microdureza Knoop ( KHN a 100g/15 seg) em duas distâncias, 100 ?m e 300 ?m em relação à luz radicular (momento I). Em seguida receberam um tipo de tratamento formando seis Grupos experimentais: 1A - hipoclorito de sódio a 0,5% , 1B – hipoclorito de sódio a 2,5%,1C – solução fisiológico, 2A – hipoclorito de sódio a 0,5% + fosfato de zinco, 2B – hipoclorito de sódio a 2,5% + fosfato de zinco e 2C – solução fisiológico + fosfato de zinco. Nos Grupos 1A, 1B e 1C após a aplicação das substâncias, as superfícies foram vedadas e decorrida uma semana um novo teste de microdureza Knoop (momento II) foi realizado. Os corpos-de-prova dos Grupos 2A, 2B e 2C receberam as soluções testadas por 60 segundos e em seguida a aplicação do cimento de fosfato de zinco, quando foram vedadas e após uma semana foram submetidos a novo teste de microdureza (momento II). Os corpos-de-prova do Grupo 2A, 2B e 2C foram observados ao MEV na região da interface cimento/dentina. Os resultados foram submetidos à análise de variância com medidas repetidas, pois cada dente foi avaliado em seis combinações entre posição (C, M e A) e distância (100 ?m e 300 ?m) e não apresentaram diferença estatisticamente significante (?=0,05) entre as combinações de posição, distância. Somente houve diferença significante (p=0,0000) quando os valores de KHN foram comparados em relação às distâncias 100 ?m e 300 ?m, sendo que a 300 ?m os valores foram maiores. Assim, os valores referentes aos 3 terços foram agrupados formando uma única média para cada distância. Pelo Teste-t pareado, as médias foram comparadas nos momentos I e II em cada distância e observou-se diferença estatisticamente significante (?=0,05) entre os grupos 1C e 2A (p=0,012 à 100 ?m, p=0,006 à 300 ?m; p=0,024 à 100 ?m e p=0,047 à 300 ?m, respectivamente). Para comparação do comportamento da dentina antes e depois dos tratamentos após uma semana, todas as médias do momento I foram juntadas num único grupo (grupo momento I). A análise de variância o grupo 1C apresentou diferença estatisticamente significante em relação ao grupo formado pelas médias de microdureza no momento I a 100 ?m e 300 ?m; 1B e 2B a 100 ?m e 1B, 2B e 2C a 300 ?m. Com isso, podemos concluir que a dentina radicular sem qualquer tratamento anti-séptico após uma semana apresenta seus valores de microdureza diminuídos de maneira significante em relação às medidas iniciais (I) e aos demais grupos experimentais.
The aim of this study was to evaluate the behavior of the bovine root-dentin under two experimental conditions: the application over the lumen surface with sodium hypochlorite solutions in concentrations of 0,5% and 2,5%, and the application of the same solutions after zinc phosphate cement was applied. The dentin microhardness was compared at two distances from the lumen, in the radicular thirds. In this study, 30 roots of bovine upper incisor were used. Each root was sectioned in the thirds: cervical (C), medium (M) and apical (A), and submitted to the Knoop microhardness test (KHN at 100g/15s) at two distances: 100 ?m and 300 ?m from lumen (I). After that, the species received one type of treatment determining six experimental groups: 1A – sodium hypochlorite 0,5%, 1B - sodium hypochlorite 2,5%, 2C – physiologic solution, 2A - sodium hypochlorite 0,5% + zinc phosphate, 2B - sodium hypochlorite 2,5% + zinc phosphate e 2C - physiologic solution+ zinc phosphate. In the Groups 1A, 1B and 1C after these solutions were applied, surfaces were sealed and one week later a new measure of microhardness (KHN) was taken (II). The Groups 2A, 2B and 2C received the tested solutions for 60 seconds following application of zinc phosphate cement, them they were sealed and after seven days a new measure was taken (II). The samples of Group 2A, 2B and 2C were observed on MEV micrographs in the cement/dentin interface. Analysis of variance with repeated measures, as each tooth was evaluated in six combinations of positions (C, M, A) and distances (100 ?m and 300 ?m), showed that there were no statistical (?=0,05) differences between combinations of position and distance. There was only significant difference (P=0,000) when KHN values were compared in relation to distances (100 and 300?m), and at 300 ?m higher values was found. The values from the thirds were grouped resulting in sole mean for each distance. Pared test-t was run to compare values I and II, in each distance significant difference was found in Group 1C and 2A (P=0,012 at 100, P=0,006 at 300; P=0,024 at 100 e P=0,047 at 300, respectively). To compare dentin behavior pre and post treatments after a week, all averages of values I were joined in a single group (group moment I). Under the Analysis of variance group 1C showed a significant difference in relation to the group formed by averages of microhardness in value I at 100 ?m and 300 ?m; 1B and 2B at 100 ?m and 1B, 2B and 2C at 300 ?m. Therefore, it can be concluded that root dentin with no anti-septic treatment after one week significantly shows decreased values of microhardness in relation to the initial measures (I) and to the others experimental groups.
APA, Harvard, Vancouver, ISO, and other styles
4

Shinkai, Rosemary Sadami Arai. "Avaliação do desenvolvimento in vitro de carie secundaria em esmalte e dentina radicular adjacentes a restauração metalica cimentada : comparação entre cimento de ionometro de vidro modificado por resina e cimento de fosfato de zinco." [s.n.], 1999. http://repositorio.unicamp.br/jspui/handle/REPOSIP/287912.

Full text
Abstract:
Orientador: Altair A. Del Bel Cury, Jaime Aparecido Cury
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-07-24T21:19:40Z (GMT). No. of bitstreams: 1 Shinkai_RosemarySadamiArai_M.pdf: 6726763 bytes, checksum: 19275c6cb737cce98018509219c5ffe2 (MD5) Previous issue date: 1999
Resumo: A cárie secundária é apontada como a principal causa de fracasso de restaurações fixas indiretas. Materiais que liberam flúor têm sido recomendados para pacientes com alto risco à cárie, mas não há evidências conclusivas sobre seu efeito em próteses fixas. Este trabalho avaliou a influência do cimento de ionômero de vidro modificado por resina no desenvolvimento in vitro de cárie em esmalte e dentina radicular adjacentes a restauração metálica cimentada, em comparação com o cimento de fosfato de zinco. A parte cervical (coroa-raiz) de 12 terceiros molares humanos foi seccionada em 4 blocos, que foram aleatoriamente divididos em 4 Grupos (n=12; 1 bloco de cada dente/grupo): FZ (restauração cimentada com cimento de fosfato de zinco), IV (restauração cimentada com ionômero de vidro modificado por resina), C 1 (controle negativo - sem restauração e sem ciclagem de pH) e C2 (controle positivo - sem restauração e com ciclagem de pH). Em FZ e IV, restaurações metálicas foram cimentadas em preparos cavitários feitos no limite coroa-raiz. Os grupos FZ, IV e C2 foram submetidos à ciclagem de pH (7 h em solução desmineralizante e 17 h em solução remineralizante), a 37°C, durante 8 ciclos. Todos os blocos foram seccionados, embutidos em resina acrílica e polidos. A leitura da microdureza Knoop do esmalte e da dentina radicular foi realizada em profundidade (em relação à superficie dental) de 20, 40, 60 e 80 'mu 'm e em distância (a partir do preparo cavitário) de 20, 120 e 220 'mu 'm. A partir dos valores de dureza, foram obtidos os valores de perda mineral. A análise estatística foi realizada por ANOVA, teste de Tukey (nível de significância de 5%) e análise de regressão. Os Grupos FZ, IV e C2 apresentaram desmineralização em relação a Cl, sendo mais superficial em esmalte que em dentina radicular. Em dentina radicular, a perda mineral de FZ e IV foi menor que a de C2. Em relação à distância da restauração, não se verificou influência da interface denterestauração. Não houve diferença significativa entre os dois tipos de cimento quanto àdureza e perda mineral em ambos os substratos dentais
Abstract: Secondary caries is reported as the main cause of failure of indirect restorations. MateriaIs with fluoride release have been recommended for patients with high risk of caries but there are no conclusive evidences of their effect on fixed prostheses. This study evaluated the influence of a resin-moditied glass ionomer cement on in vitro caries development in enamel and root dentin around metallic restoration. The cervical portion (crown-root) of twelve third molars were sectioned in four blocks, which were randomly divided into four Groups (n=12; 1 block from each tooth/group): FZ (restoration luted with zinc phosphate cement), IV (restoration luted with resin-modified glass ionomer cement), Cl (negative control - no restoration and no cycling), and C2 (positive control - no restoration and cycling). In FZ and IV, metallic restorations were luted at crown-root junction. FZ, IV and C2 were submitted to a pH-cycling model (7 h in a demineralizing solution and 17 h in a remineralizing one for 8 cycles) at 37°C. All blocks were sectioned, embedded in acrylic resin and polished. Enamel and root dentin demineralization were evaluated through cross-sectional microhardness Knoop measures taken at 20, 40, 60, and 80 'mu 'm of depth (from the outer surface), and at 20, 120, and 220 'mu'm of distance from the cavity margins. Mineral loss values were calculated from Knoop hardness numbers. Data were analysed by means of ANOVA Tukey's test (at 5% level of significance) and regression analysis. Groups FZ, IV and C2 showed demineralization in relation to Cl, which was more superficial in enamel than in root dentin. In root dentin, mineralloss in EZ and IV waS smaller than in C2. Distance from the cavity margins was not significant. There was no difference between resin-modified glass-ionomer cement and zinc phosphate cement concerning artificial secondary caries development in both dental substrates
Mestrado
Protese Dental
Mestre em Clínica Odontológica
APA, Harvard, Vancouver, ISO, and other styles
5

Tubelo, Rodrigo Alves. "Desenvolvimento, aplicação e avaliação de um objeto virtual de aprendizagem no conhecimento teórico e desempenho prático de alunos de Odontologia sobre o cimento de fosfato de zinco." reponame:Biblioteca Digital de Teses e Dissertações da UFRGS, 2015. http://hdl.handle.net/10183/125815.

Full text
Abstract:
O objetivo do presente estudo foi desenvolver e avaliar um Objeto Virtual de Aprendizagem (OVA) sobre agentes de cimentação com ênfase no Cimento de Fosfato de Zinco (CFZ) e verificar a sua influência no conhecimento teórico e habilidade prática em estudantes de graduação em Odontologia. Foram descritas a metodologia e as ferramentas necessárias para o desenvolvimento do OVA. Foi criado um questionário de avaliação pedagógica e técnica do OVA utilizando a escala Likert (0 nunca e 4 sempre). O OVA foi aplicado em 46 estudantes de graduação em odontologia que foram randomizada em 4 grupos: OVA Imediato (GIOVA n=9), OVA longitudinal (GLOVA n=15) e dois grupos controles sem OVA (GIC n=9 and GLC n=13). Os grupos imediatos tiveram acesso ao OVA ou livro por 20 minutos antes do teste de habilidade, enquanto os grupos longitudinais tiveram acesso por 15 dias. O desenvolvimento do objeto permitiu a criação de uma simulação virtual da manipulação do CFZ. O questionário de avaliação mostrou que aproximadamente 65% dos alunos deram 4 pontos e 14,85% deram 3 pontos. O software utilizado foi capaz de reunir as mídias em um OVA, sendo que esse objeto com simulação virtual sobre o CFZ possui alta taxa de aprovação entre os alunos de odontologia. Um pré e pós-teste de conhecimento teórico e dois testes laboratoriais foram realizados por todos os grupos e avaliados por examinadores cegos. Os estudantes que utilizaram o OVA obtiveram melhores resultados nos testes de habilidade do que seus controles. O pós-teste de conhecimento mostrou diferença estatística nos grupos longitudinais GLC (6.0±1.15) e GLOVA (7.33±1.43). Menor espessura de película foi encontrada com diferença estatística nos grupos que utilizaram o OVA: (GIC 25±9,3) e GIOVA (16,24±5,17); GLC (50±27,08) e GLOVA (22,5±9,65). Os grupos que utilizaram o OVA obtiveram maior tempo de presa do que seus controles, e o grupo imediato mostrou diferença estatística GIC (896±218,90) e GIOVA (1138,5±177,95). O OVA com simulação virtual sobre o CFZ possui alta taxa de aprovação entre os alunos de odontologia. O CFZ manipulado por estudantes que utilizaram o OVA tiveram melhores propriedades mecânicas nos testes laboratoriais. Portanto, os grupos que utilizaram o OVA obtiveram melhor habilidade clínica que seus controles e maior retenção de conhecimento após 15 dias.
The aim of this study was to develop and evaluate a Virtual Learning Object (VLO) on cementing agents with emphasis on Zinc Phosphate Cement (ZPC), verifying its influence in theoretical knowledge and practical ability of dentistry undergraduates. The methodology and tools needed to develop the VLO were described and a pedagogical and technique assessment using the Likert Scale (0 never and 4 always) about the object was created. The VLO was applied to 46 dentistry undergraduates randomized into 4 groups: immediate VLO (GIOVA n=9), longitudinal VLO (GLOVA n=15) and two control groups without VLO (GIC n=9 and GLC n=13). Immediate groups had access to VLO or book for 20 minutes before the skill test, while the longitudinal groups had access to VLO or book for 15 days. The development of the object allowed the creation of a virtual simulation of ZPC manipulation. The questionnaire indicates that, approximately, 65% of students gave 4 points to VLO and 14.85% gave 3 points to it. The software used to construct the VLO enables to gather all media in one object, including the virtual simulation on the ZPC, that has a high approval rating among dentistry undergraduates. Pre and post test theoretical knowledge and two laboratory skill tests were performed by all groups and evaluated by blinded examiners. Students who used the VLO obtained better results in skill tests than their controls. Theoretical knowledge showed statistically significant differences in post-test of longitudinal groups: GLC (6.0 ± 1.15) and GLOVA(7:33 ± 1.43). VLO groups achieved a smaller film thickness in the skill test with statistical difference: (GIC 25 ± 9.3) and GIOVA (16.24 ± 5.17); GLC (50 ± 27.08) and GLOVA (22.5 ± 9.65). The higher setting time occurred in the VLO groups, and the immediate group showed a significant difference: GIC (896 ± 218.90) and GIOVA (1138.5 ± 177.95). The VLO with virtual simulation on ZPC has high approval rating among dentistry undergraduates. The ZPC manipulated by students who used the VLO had better mechanical properties in laboratory tests. Therefore, the groups that used the VLO had better clinical skills than their controls and greater retention of knowledge after 15 days.
APA, Harvard, Vancouver, ISO, and other styles
6

Nogueira, Junior Lafayette [UNESP]. "Análise histopatológica do comportamento pulpar, pós cimentação de coroas totais metálicas com cimentos de ionômero vítreo e fosfato de zinco." Universidade Estadual Paulista (UNESP), 1997. http://hdl.handle.net/11449/113964.

Full text
Abstract:
Made available in DSpace on 2015-01-26T13:21:25Z (GMT). No. of bitstreams: 0 Previous issue date: 1997-06-18Bitstream added on 2015-01-26T13:30:30Z : No. of bitstreams: 1 000124730.pdf: 2908665 bytes, checksum: f09acac36958ca4d39a995e20861f7e9 (MD5)
Com o objetivo de avaliar histopatologicamente o comportamento pulpar pós-cimentação de coroas totais metálicas (CTM) com um cimento de fosfato de zinco (Lee Smith, Vigodent) e dois cimentos de ionômero vítreo (Ketac-Cem, ESPE; Vidrion C, SSWhite), foram realizados 27 preparos coronários em pré-molares íntegros indicados para exodontia com a finalidade de tratamento ortodôntico. As exodontias foram realizadas após três, dez e trinta dias da cimentação. Para o exame histopatólogico a polpa foi removida do dente e corada pelo hematoxilina e eosina. Os resultados mostraram que aos três dias, que seis das nove polpas apresentavam alguma reação inflamatória, o comportamento entre os cimentos foi diferente quanto ao grau de resposta inflamatória, a reação inflamatória persistiu após trinta dias com o Lee Smith (CFZ) e Ketac-Cem (CIV), o grupo do Vidrion C (CIV) foi o qual apresentou melhor biocompatibilidade. A metodologia usada permitiu uma avaliação das condições pulpares em um período mais curto que o processo convencional de descalcificação, entretanto não possibilitou a observação da interação polpa/dentina
The purpose of this study was to conduct an histological evaluation of pulp rections of teeth after cementation of complete metal crowns with one of the following luting agents: zinc phosphate cement (ZPC) (Lee Smith, Vigodent) and two glass ionomer cements (Ketac Cem, ESPE, Vidrion C, SSWhite). Twenty seven sound bicuspids scheduled for extraction by orthodontic treatment were prepared for complete crowns, casts were made and luted with one of the above cements. Three, ten and thirty days after cementation the teeth were removed, split in two halves and the pulps detached from one of the halves, stained with H.E. and pulpal reactions assessed by optical microscopy. Results showed dissimilar inflammatory responses that were associated to the different cementing agents. For specimens of the ZPC and Ketac-Cem groups the inflammatory reaction subsided for 30 days. For the Vidrion C group only 2 out of 9 specimens showed pulpal inflammatory reactions. Therefore, regarding biocompatibility, best results were seen with the specimens ofthe Vidríon C group. The method allowed a quick assessment of pulp conditions when compared to the traditional decalcifiyng process. However, observations of dentin-pulp relationships could not be noticed
APA, Harvard, Vancouver, ISO, and other styles
7

Nogueira, Junior Lafayette. "Análise histopatológica do comportamento pulpar, pós cimentação de coroas totais metálicas com cimentos de ionômero vítreo e fosfato de zinco /." São José dos Campos, 1997. http://hdl.handle.net/11449/113964.

Full text
Abstract:
Orientador: José Eduardo Junho de Araújo
Banca: Cícero Eleutério da Silva Filho
Banca: Yasmin Rodarte Carvalho
Resumo: Com o objetivo de avaliar histopatologicamente o comportamento pulpar pós-cimentação de coroas totais metálicas (CTM) com um cimento de fosfato de zinco (Lee Smith, Vigodent) e dois cimentos de ionômero vítreo (Ketac-Cem, ESPE; Vidrion C, SSWhite), foram realizados 27 preparos coronários em pré-molares íntegros indicados para exodontia com a finalidade de tratamento ortodôntico. As exodontias foram realizadas após três, dez e trinta dias da cimentação. Para o exame histopatólogico a polpa foi removida do dente e corada pelo hematoxilina e eosina. Os resultados mostraram que aos três dias, que seis das nove polpas apresentavam alguma reação inflamatória, o comportamento entre os cimentos foi diferente quanto ao grau de resposta inflamatória, a reação inflamatória persistiu após trinta dias com o Lee Smith (CFZ) e Ketac-Cem (CIV), o grupo do Vidrion C (CIV) foi o qual apresentou melhor biocompatibilidade. A metodologia usada permitiu uma avaliação das condições pulpares em um período mais curto que o processo convencional de descalcificação, entretanto não possibilitou a observação da interação polpa/dentina
Abstract: The purpose of this study was to conduct an histological evaluation of pulp rections of teeth after cementation of complete metal crowns with one of the following luting agents: zinc phosphate cement (ZPC) (Lee Smith, Vigodent) and two glass ionomer cements (Ketac Cem, ESPE, Vidrion C, SSWhite). Twenty seven sound bicuspids scheduled for extraction by orthodontic treatment were prepared for complete crowns, casts were made and luted with one of the above cements. Three, ten and thirty days after cementation the teeth were removed, split in two halves and the pulps detached from one of the halves, stained with H.E. and pulpal reactions assessed by optical microscopy. Results showed dissimilar inflammatory responses that were associated to the different cementing agents. For specimens of the ZPC and Ketac-Cem groups the inflammatory reaction subsided for 30 days. For the Vidrion C group only 2 out of 9 specimens showed pulpal inflammatory reactions. Therefore, regarding biocompatibility, best results were seen with the specimens ofthe Vidríon C group. The method allowed a quick assessment of pulp conditions when compared to the traditional decalcifiyng process. However, observations of dentin-pulp relationships could not be noticed
Mestre
APA, Harvard, Vancouver, ISO, and other styles
8

Figueiro, Claudio. "Influencia da convergencia axial na adaptação e infiltração marginal de coroas totais fixadas com cimentos de fosfato de zinco, ionomero de vidro e resinoso." [s.n.], 1997. http://repositorio.unicamp.br/jspui/handle/REPOSIP/289082.

Full text
Abstract:
Orientador: Frederico Andrade e Silva
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-07-23T01:30:39Z (GMT). No. of bitstreams: 1 Figueiro_Claudio_M.pdf: 4596354 bytes, checksum: 8f47d3233a23e932d54fe693033e5c6f (MD5) Previous issue date: 1997
Resumo: Este estudo avaliou a influência da convergência axial na adaptação e infiltração marginal de coroas totais fixadas com cimentos de fosfato de zinco (S.S. White), ionômero de vidro (Vitremer) e resinoso (Panavia 2 hx). Foram realizados preparos padronizados do tipo coroa total em 60 dentes molares recém extraídos, nos quais foram confeccionadas coroas metálicas em NiCr. Foram formados 12 grupos de acordo com: o agente cimentante utilizado, a convergência axial de 12° e de 16°, e a utilização ou não de ciclagem térmica. As coroas foram cimentadas seguindo as orientações dos fabricantes, utilizando uma carga estática de 9 Kg durante 7 minutos. Os grupos que sofreram ciclagem térmica foram submetidos a um regime de 1500 ciclos nas temperaturas de 10°C e de 50°C. Todos os grupos foram imersos em corante azul de metileno a 1 %, permanecendo em temperatura de 37°C durante 24 h. As coroas foram seccionadas longitudinalmente utilizando um disco de aço diamantado. Foi efetuado polimento de todas as secções obtidas em uma politriz manual: A adaptação e a infiltração foram medidas utilizando um microscópio comparador (LEITZ), com um aumento de 40x. Os resultados foram agrupados, e suas médias submetidas a uma análise de variância (com um critério de classificação). O resultado da análise de variância mostrou-se significante ao nível de 5%, sendo realizado o teste de Tukey ao nível de 5% de significância. Concluiu-se que: I)A Adaptação das coroas foi melhorada com o aumento da convergência, para os cimentos de ionômero de vidro e resinoso. 2) A ordem de classificação dos agentes cimentantes avaliados quanto à adaptação foi: fosfato de zinco, ionômero de vidro, resinoso, da maior para a menor discrepância. 3) A infiltração não sofreu alteração em relação ao grau de convergência das paredes axiais. 4) O cimento resinoso apresentou a menor infiltração entre os agentes cimentantes avaliados, sendo que os cimentos de fosfato de zinco e ionômero de vidro não apresentaram diferença em relação à infiltração. 5) A utilização da ciclagem térmica aumentou a infiltração, contudo não alterou a classificação dos agentes cimentantes
Abstract: The objective of this study was to evaluate the influence ofaxial convergence on the marginal adaptation and microleakage of cemented complete crowns with Zinc Phosphate (S. S. WHITE), composite resinglass ionomer hybrid Vitremer Luting (3M) and resin cement Panavia 21 EX (KURARA Y). Sixty recently extracted molars were prepared to receive full cast crowns, standardized preparations were made and the crowns were made in a Ni-Cr alloy. Twelve groups were formed according to: luting agents, axial convergence (12° and 16°) and the utilization or not utilization of thermocycling. The crowns were cemented according to the manufacturer' s instructions, utilizing a 9 Kg static load for seven minutes. The specimens were thermocycled for 1500 cycles (1050°C). All groups were immersed in 1 % Methylen Blue solution at 37°C :f: 2°C for 24 hours. The crowns were sectioned with a diamond disk and polished. The marginal adaptation and microleakage were measured using a microscope with 40X of magnification (LEITZ). The results were submitted to the Analysis of variance (ANOV A). The results of Analysis was significant at the 5% leveI, and the Tukey multiple comparisons test . was applied at the 5% leveI of significance. We concluded: 1) The crown adaptation was improved with the increase of the convergence to the glass ionomer and resin cement. 2) The classification order of the lutings cements evaluated according to adaptation was: zinc phosphate, glass ionomer, and resin cement, from the highest to the lowest discrepancy. 3) The convergence angle didn't change the microleakage. 4) The resin cement showed less microleakage than the other luting agent groups. The microleakage was comparable to zinc phosphate and glass ionomet<. 5) The termocycling increased the microleakage but It didn't change the rank of the luting cements to the microleakage
Mestrado
Protese
Mestre em Clínica Odontológica
APA, Harvard, Vancouver, ISO, and other styles
9

Pavanelli, Carlos Augusto [UNESP]. "Análise da espessura da película de cimentos de ionômero vítreo e fosfato de zinco, empregados na cimentação de coroas totais metálicas, preparadas in vivo." Universidade Estadual Paulista (UNESP), 1997. http://hdl.handle.net/11449/131864.

Full text
Abstract:
Made available in DSpace on 2015-12-10T14:22:18Z (GMT). No. of bitstreams: 0 Previous issue date: 1997-06-18. Added 1 bitstream(s) on 2015-12-10T14:28:21Z : No. of bitstreams: 1 000125620.pdf: 2996163 bytes, checksum: f515bf3dab8364f60e260ee782ec47e0 (MD5)
A presente pesquisa consistiu em analisar a espessura da película de cimentos de ionômero vítreo (Vidrion C, SS WHITE, Brasil; Ketac Cem, ESPE, Alemanha) in vivo, comparando os resultados com um cimento de fosfato de zinco (Lee Smith, TELEDYNE WATER PIK, USA), na cimentação de coroas totais metálicas. Foram utilizados 21 dentes íntegros, com exodontia indicada para fins ortodônticos, que foram preparados para receber coroa total metálica. O processamento laboratorial das fundições, foi feito em laboratório comercial, de forma padronizada. Todas as coroas foram aliviadas internamente, através da prévia aplicação de cinco camadas de verniz espaçador sobre os troquéis. As cimentações, foram feitas, inicialmente sob pressão digital, seguida por pressão de assentamento pela oclusão, com um mordente de madeira de laranjeira, interposto entre a coroa e a arcada antagonista. Os resultados mostraram, pelo teste estatístico ANOVA, valores semelhantes para os três cimentos, ao nível de 1%. Entretanto, quando a espessura da película do cimento foi analisada sob as variáveis cimento e posição de mensuração na superfície do dente preparado, encontrou-se que nas paredes axiais, havia diferença entre o cimento Lee Smith e o Vidrion C, onde os valores para o Vidrion foram significativamente menores. Nas demais posições analisadas, não houve diferença significante ao nível de 5%. Quando esses mesmos valores foram apreciados através de representação gráfica (diagrama, do tipo BOX-PLOT), do cimento em função da posição de mensuração, observou-se, no caso do cimento de fosfato de zinco, uma tendência de distribuição dos valores, por toda a faixa compreendida entre o valor máximo e o valor mínimo da película. Os cimentos de ionômero vítreo, tenderam a concentrar seus valores, em relação à faixa de distribuição, a níveis mais baixos que o cimento de fosfato de zinco. O Vidrion C, em particular, foi o que...
This study evaluated the film thicknesses of two GIC cements (Vidrion C, SS WHITE, Brazil; Ketac Cem, ESPE, Germany) and one zinc phosphate cement (Lee Smith, TELEDYNE, USA), used for final cementation of complete metal crowns. Twenty-one teeth scheduled for extraction due to orthodontic treatment were prepared for complete metal crowns. Dies were relieved with 5 layers of die varnish spacer. The crowns were manufactured by a commercial laboratory (with standardized procedures as much as possible) and cemented first with finger pressure and later by occlusion pressure using orange wood sticks. Results submitted to an ANOVA test showed that all cements had a similar behavior showing no significant statistical differences (p<0.01). A film thickness analysis of 7 selected preparations sites, showed that only axial positions, presented differences between Lee Smith and Vidrion C cements, the latter presenting lower significant values. For other positions studied, the three cements showed no significant statistical differences (p<0.05). Technical exploratory analysis of data by a BOX PLOT graphic showed for the ZPC a broad film thickness value distributions (from the highest to the lowest values) related to type of cement and measurement values. For glass ionomer cement the graphic presented values concentrating at lower levels than zinc phosphate cement. This was still more evident for the Vidrion C cement
APA, Harvard, Vancouver, ISO, and other styles
10

Pavanelli, Carlos Augusto. "Análise da espessura da película de cimentos de ionômero vítreo e fosfato de zinco, empregados na cimentação de coroas totais metálicas, preparadas "in vivo" /." São José dos Campos, 1997. http://hdl.handle.net/11449/131864.

Full text
Abstract:
Orientador: José Eduardo Junho de Araújo
Banca: Eulália Maria Martins Silva
Banca: Marcos Yasunóri Maekawa
Resumo: A presente pesquisa consistiu em analisar a espessura da película de cimentos de ionômero vítreo (Vidrion C, SS WHITE, Brasil; Ketac Cem, ESPE, Alemanha) in vivo, comparando os resultados com um cimento de fosfato de zinco (Lee Smith, TELEDYNE WATER PIK, USA), na cimentação de coroas totais metálicas. Foram utilizados 21 dentes íntegros, com exodontia indicada para fins ortodônticos, que foram preparados para receber coroa total metálica. O processamento laboratorial das fundições, foi feito em laboratório comercial, de forma padronizada. Todas as coroas foram aliviadas internamente, através da prévia aplicação de cinco camadas de verniz espaçador sobre os troquéis. As cimentações, foram feitas, inicialmente sob pressão digital, seguida por pressão de assentamento pela oclusão, com um mordente de madeira de laranjeira, interposto entre a coroa e a arcada antagonista. Os resultados mostraram, pelo teste estatístico ANOVA, valores semelhantes para os três cimentos, ao nível de 1%. Entretanto, quando a espessura da película do cimento foi analisada sob as variáveis cimento e posição de mensuração na superfície do dente preparado, encontrou-se que nas paredes axiais, havia diferença entre o cimento Lee Smith e o Vidrion C, onde os valores para o Vidrion foram significativamente menores. Nas demais posições analisadas, não houve diferença significante ao nível de 5%. Quando esses mesmos valores foram apreciados através de representação gráfica (diagrama, do tipo BOX-PLOT), do cimento em função da posição de mensuração, observou-se, no caso do cimento de fosfato de zinco, uma tendência de distribuição dos valores, por toda a faixa compreendida entre o valor máximo e o valor mínimo da película. Os cimentos de ionômero vítreo, tenderam a concentrar seus valores, em relação à faixa de distribuição, a níveis mais baixos que o cimento de fosfato de zinco. O Vidrion C, em particular, foi o que...
Abstract: This study evaluated the film thicknesses of two GIC cements (Vidrion C, SS WHITE, Brazil; Ketac Cem, ESPE, Germany) and one zinc phosphate cement (Lee Smith, TELEDYNE, USA), used for final cementation of complete metal crowns. Twenty-one teeth scheduled for extraction due to orthodontic treatment were prepared for complete metal crowns. Dies were relieved with 5 layers of die varnish spacer. The crowns were manufactured by a commercial laboratory (with standardized procedures as much as possible) and cemented first with finger pressure and later by occlusion pressure using orange wood sticks. Results submitted to an ANOVA test showed that all cements had a similar behavior showing no significant statistical differences (p<0.01). A film thickness analysis of 7 selected preparations sites, showed that only axial positions, presented differences between Lee Smith and Vidrion C cements, the latter presenting lower significant values. For other positions studied, the three cements showed no significant statistical differences (p<0.05). Technical exploratory analysis of data by a BOX PLOT graphic showed for the ZPC a broad film thickness value distributions (from the highest to the lowest values) related to type of cement and measurement values. For glass ionomer cement the graphic presented values concentrating at lower levels than zinc phosphate cement. This was still more evident for the Vidrion C cement
Mestre
APA, Harvard, Vancouver, ISO, and other styles
More sources

Conference papers on the topic "Cimento de fosfato de zinco"

1

Brito, Tiago Rafael Ferreira de, and Célia Aparecida Lino dos Santos. "DESEMPENHO DE PRÉ-TRATAMENTOS DE FOSFATO DE ZINCO DRY-IN-PLACE FRENTE À CONFORMAÇÃO MECÂNICA DE CHAPAS DE AÇOS BAIXO CARBONO." In 52º Seminário de Laminação. São Paulo: Editora Blucher, 2017. http://dx.doi.org/10.5151/1983-4764-27113.

Full text
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!

To the bibliography