Academic literature on the topic 'Circuit breaker controlling'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Circuit breaker controlling.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "Circuit breaker controlling"

1

Shriwastava, Rakesh G., Pawan C. Tapre, Rajendra M. Rewatkar, et al. "Hardware implementation of safety smart password based GSM module controlling circuit breaker." International Journal of Applied Power Engineering (IJAPE) 14, no. 2 (2025): 441. https://doi.org/10.11591/ijape.v14.i2.pp441-448.

Full text
Abstract:
This research work highlights the hardware implementation of safety smart password-based GSM module controlling circuit breaker. Safety is the major concern in daily life for domestic activities. In current scenario, accidental death of a lineman are the major issues and to protect operators for the same. To control circuit breakers, passwords security is essential for lineman. Due to that electrical accident’s ratio is increased day to day life at the time of repairing the lines. It is also done due to lack of communication and coordination between maintenance and substation. For safety of lineman, on and off line turning operation is proposed. Secure password is for breaker operation and maintenance. In the proposed system, password is sent to the line operator's mobile phone and GSM module by automatic voltage regulator (AVR) microcontroller. Entered password and password received by the GSM receiver is match so circuit breaker will be smoothly operated. If password is incorrect, message will appear on the LCD display for security purposed and message sent to control room regarding unauthorized access to the system.
APA, Harvard, Vancouver, ISO, and other styles
2

Shriwastava, Dr Rakesh G. "Smart Safety with Password Based GSM Module Controlling Circuit Breaker." International Journal for Research in Applied Science and Engineering Technology 12, no. 5 (2024): 2148–54. http://dx.doi.org/10.22214/ijraset.2024.62038.

Full text
Abstract:
Abstract: This paper focus on Smart safety with password based GSM module controlling circuit breaker. In our daily life, Safety is the major concern for all activities. Accidental death of a lineman is often read and proven in current scenario. In view, safety measures to protect operators are considered to be very necessary in current working. Using passwords for security, Electrical lineman security systems are used to control circuit breakers. Serious electrical accidents occurs becoming increasingly, when repairing power lines. It is happen due to lack of communication and coordination between maintenance and substation personnel. In the proposed system, the on and off line turning operation with the lineman to ensure the safety of linemen. For that, a secure password is required to operate the breaker operation and maintenance point of view. First request is registered and password is sent to the line operator's mobile phone and GSM module by AVR microcontroller. Entered password and password received by the GSM receiver are compare. If password is match, the operation of circuit breaker will be smoothly operate. The operator gave three chances for incorrect password otherwise message will appear on the LCD display for security purposed. It also sent the message control room regarding unauthorized access to the system.
APA, Harvard, Vancouver, ISO, and other styles
3

Safi, B. F., L. T. Pham, and M. J. Busby. "High voltage circuit breaker supported on a base isolating tripod for earthquake protection." Bulletin of the New Zealand Society for Earthquake Engineering 22, no. 3 (1989): 145–54. http://dx.doi.org/10.5459/bnzsee.22.3.145-154.

Full text
Abstract:
The 1987 Bay of Plenty earthquake caused the total destruction of a 220 kV circuit breaker. Failures occurred in the porcelain columns supporting the Interrupter Heads.
 There are many other circuit breakers of the same type in the national grid. To protect these circuit breakers from earthquake damage, a proposal is made to replace the existing support stand with a base isolating tripod.
 On the tripod, Helical Springs and oil filled dampers are used to control the earthquake induced motion of the circuit breaker. By controlling this motion the forces on the porcelain support column are reduced to a safe level.
 The design is modelled using a multi degree of freedom system subjected to Response Spectrum and Time History analyses. The model produces results which are consistent with tests, and confirms the design parameters selected by a single degree of freedom approximation.
 The result is an economical tripod stand design which is expected to protect the circuit breaker from earthquake ground accelerations up to twice the level of the 1940 El Centro earthquake. This level of earthquake is considerably stronger than the 1987 Bay of Plenty earthquake.
APA, Harvard, Vancouver, ISO, and other styles
4

Xu, Lili, Yuting Yu, and Chunmian Chen. "Design and research of a new type of electromagnetic vacuum circuit breaker." Advances in Engineering Technology Research 10, no. 1 (2024): 263. http://dx.doi.org/10.56028/aetr.10.1.263.2024.

Full text
Abstract:
The vacuum circuit breaker is the main switch of electric locomotive, controlling the on and off of the main circuit of electric locomotive. Existing vacuum circuit breaker of electric locomotives generally the air-driven, electromagnetic retention, this vacuum circuit breaker structure is simple and stable performance is high, but large mass, high air tightness requirements, the shortcomings of the noise. The design of this design according to the actual situation of electric locomotives, the design of a vacuum circuit breaker does not require compressed air drive, electronic control of mechanical manipulation mode of the circuit breaker, the new vacuum circuit breaker using electromagnet drive device to realize the vacuum circuit breaker opening and closing operation, while increasing the energy storage device for the vacuum circuit breaker closing operation to provide the necessary energy. This new type of electromagnetic vacuum circuit breaker has the characteristics of small size, simple structure, low cost and high reliability performance.
APA, Harvard, Vancouver, ISO, and other styles
5

Mokhberdoran, Ataollah, Oriol Gomis-Bellmunt, Nuno Silva, and Adriano Carvalho. "Current Flow Controlling Hybrid DC Circuit Breaker." IEEE Transactions on Power Electronics 33, no. 2 (2018): 1323–34. http://dx.doi.org/10.1109/tpel.2017.2688412.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Su, Jiawei, Ken Chen, and Qi Wang. "Difference Analysis of Operation Stability of Vacuum Circuit Breaker in 10KV Power Distribution System." Journal of Physics: Conference Series 2202, no. 1 (2022): 012047. http://dx.doi.org/10.1088/1742-6596/2202/1/012047.

Full text
Abstract:
Abstract As an important part of power transmission and transformation equipment, vacuum circuit breakers have become the core device for protecting and controlling electrical lines in high-voltage electrical equipment. This paper expounds the different types of test methods for the preventive test of high and low voltage distribution rooms. Taking the 10kV high and low voltage distribution system in use as the analysis object, 37 units are randomly selected as samples, and statistical principles are used to analyze differences, extract point estimation and interval Estimating eigenvalues, judging the stability and balance of the overall operation of the vacuum circuit breaker in the power distribution system, and providing a basis for the safe use and preventive testing of the power distribution system.
APA, Harvard, Vancouver, ISO, and other styles
7

Radmanesh, Hamid, and Razieh Salimi Atani. "Novel Circuit Breaker Modeling in 275kV Substation." ECTI Transactions on Electrical Engineering, Electronics, and Communications 11, no. 2 (2013): 1–7. http://dx.doi.org/10.37936/ecti-eec.2013112.170623.

Full text
Abstract:
Ferroresonance an electrical phenomenon may cause overvoltages in the electrical power system. In this paper, an overview of available papers is provided, at rst ferroresonance is introduced and then various type of ferroresonance in a voltage transformer (VT) is simulated. Then eect of new model of circuit breaker (CB) on damping ferroresonance oscillation is examined. Finally eect of earth resistance on the stabilizing these oscillations in the case of nonlinear core loss has been studied. Core loss is modelled by third order power series in terms of voltage and includes nonlinearities in core loss. For conrmation, the simulation is done on a one phase voltage transformer rated 100VA, 275kV. The simulation results reveal that novel modeling of circuit breaker exhibits great controlling eect on ferrores- onance overvoltages.
APA, Harvard, Vancouver, ISO, and other styles
8

Liu, Zhiheng, Xiongying Duan, Minfu Liao, Guowei Ge, and Jiyan Zou. "A model-based measurement method for intelligent circuit breaker with data communication." Transactions of the Institute of Measurement and Control 40, no. 6 (2017): 1854–62. http://dx.doi.org/10.1177/0142331217693672.

Full text
Abstract:
In this paper, an object-oriented information model of an intelligent vacuum circuit breaker based on its physical structure and function (service) was established to integrate the measuring information flow of field parameters, the monitoring information flow of status data, and the operating and controlling information flow. The status parameters of the intelligent vacuum breaker were detected by analysing the principles and methods based on IEC61850 and IEC62271 standards. The IEC 61850 standard repository can be extended according to the characteristics of the intelligent vacuum breaker status parameters, and the IED server model was constructed to be suitable for the vacuum breaker. A key feature of the new method is the use of a multimode fibre that is incorporated into the IED server model to transmit the status parameters from the target to the sensor. The main characteristic of the measurement method is that it exhibits real-time transmission of data collection. The model includes temperature testing of the switch contact, vacuum arc testing, detection of vacuum switch motion and primary circuit parameters testing. Furthermore, we show how the IEC61850 standard can be used to give a better insight on data communication of the data collector and intelligent circuit breaker. Experimental results showed that the feasibility of intelligent vacuum breaker status monitoring through the switching-on test. It purposes to achieve information integration and a frame communication platform for the intelligent vacuum breaker.
APA, Harvard, Vancouver, ISO, and other styles
9

Cui, Puyi, Guoli Li, Qian Zhang, Qinglian He, Zhong Chen, and Wei Yang. "Improved assembly DC circuit breaker based on resonant current injection." PLOS ONE 19, no. 7 (2024): e0304979. http://dx.doi.org/10.1371/journal.pone.0304979.

Full text
Abstract:
DC circuit breakers (DCCBs) with high breaking capacity and low cost are necessary for quick fault clearance in DC networks. The assembly DC circuit breakers (ADCCBs) have a main breaking section (MBS) and a sub-breaking sections (SBS) for each line, which greatly reduce the cost. But in conventional operation, it bears high voltage for a long time when there is a main switch grounding process in any line fault action. To address this problem, a multiport assembly circuit breaker based on current injection (CI-MPACB) is proposed, which is able to generate a resonant current with increasing amplitude by controlling the duty cycle of Integrated Gate-Commutated Thyristors (IGCTs). Then the resonant current is injected into the SBS to generate current zero crossing and arc extinction. A complex frequency domain circuit analysis is performed on the MBS to describe the action logic as well as the commutation characteristics. In addition, the parameters of each component of the MBS are subject to multiple constraints and reasonable design to ensure the fault current could be cut off quickly and reliably. The cost of existing design is greatly reduced due to the design idea of resonant current injection device parameter selection. Finally, a PSCAD/EMTDC simulation confirms the opening viability of CI-MPACB and the accuracy of the parameter design. The test results show that the designed CI-MPACB can cut off DC fault lines.
APA, Harvard, Vancouver, ISO, and other styles
10

Patil, Nitin S., Tejas D. Patil, Prashwa S. Patil, Onkar A. Salokhe, and Arihant V. Patil. "Electric Line Man Safety with Password Based Circuit Breaker." Journal of Advances in Electrical Devices 7, no. 2 (2022): 1–4. http://dx.doi.org/10.46610/jaed.2022.v07i02.001.

Full text
Abstract:
The endeavor is deliberate to control an electrical transfer by using inclusive of a thriller word for the flourishing of electric person.Fundamental electrical disappointments to linemen are moving during electrically energized line fix because of nonappearance of correspondence and co-relationship among the safeguarding group of laborers and electric controlled substation gathering of specialists. This proposed shape gives a reaction that guarantees the security of care staff that is line person. The control to turn ON/OFF the line might be remained mindful of with the guide of the street fellow essentially in gentle of reality that this machine has a course of action such a lot of that a spine chiller key should canvas the electrical switch (On/Off). This machine is completely constrained using a microcontroller from the 8051 own loved ones. A Bluetooth contraption is a chiller key. The entered secret articulation is separated and the thrill ride key is put aside inside the (ROM) of the microcontroller. Expecting the spine chiller word inserted is definite, handiest the road conceivably created to become On/Off. The graduation/deactivation of the electrical switch is shown via a gentle that turns ON or OFF. Additionally, this endeavor in fate might be advanced via the utilization of EEPROM, for the client to trade the secret articulation for extra was given shape connection. It can moreover be connected with a GSM modem for genuinely controlling the electrical switch through SMS.
APA, Harvard, Vancouver, ISO, and other styles
More sources

Book chapters on the topic "Circuit breaker controlling"

1

Narita, Masao, Naoki Yaegashi, Minoru Kobayashi, and Shigeru Inaba. "Controlling Bounce of Vacuum Circuit Breakers’ Contacts." In Emerging Challenges for Experimental Mechanics in Energy and Environmental Applications, Proceedings of the 5th International Symposium on Experimental Mechanics and 9th Symposium on Optics in Industry (ISEM-SOI), 2015. Springer International Publishing, 2016. http://dx.doi.org/10.1007/978-3-319-28513-9_34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Shijing Wu, Haibo Zhang, Zenglei Zhang, and Wenqiang Zhao. "The Analysis of Axial Slippage of the Sleeve in Circuit Breaker Operating Mechanism." In Advances in Transdisciplinary Engineering. IOS Press, 2014. https://doi.org/10.3233/978-1-61499-440-4-389.

Full text
Abstract:
The circuit breaker plays a key role in the protection and controlling of high voltage transmission and distribution network. The operating mechanism is one of the most important execution units and its reliability level directly relates to the security of grid. As a result of repeating operation in practice, plastic deformation occurs in the sleeve of circuit breaker operating mechanism, and even the sleeve slips axially and falls from institutions, which seriously reduces the reliability of the circuit breaker operating mechanism. In view of the lack of current research on the phenomenon of sliping of the sleeve in circuit breaker operating mechanism, the problem of axial slip of the sleeve has been studied and the kinematic model of circuit breaker operating mechanism has been established in this paper. The cause of axial slippage of the sleeve has been analyzed through ABAQUS finite element simulation platform. Finally, part of parameters at the hinge are optimized using Taguchi method to achieve the goal of reducing axial slippage of the sleeve.
APA, Harvard, Vancouver, ISO, and other styles

Conference papers on the topic "Circuit breaker controlling"

1

Kumar, Pankaj, and Rajashree Bhokare. "IOT based Monitoring and Rapid Controlling Circuit Breaker." In 2024 International Conference on Intelligent Systems and Advanced Applications (ICISAA). IEEE, 2024. https://doi.org/10.1109/icisaa62385.2024.10828907.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Ciulica, Dumitru, Manuela Panoiu, Caius Panoiu, and Sergiu Mezinescu. "Researches about Controlling Switching SF6 Circuit Breaker Transition Regime." In 2020 8th International Conference on Control, Mechatronics and Automation (ICCMA). IEEE, 2020. http://dx.doi.org/10.1109/iccma51325.2020.9301534.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Kwak, Boseung, Juwon Kim, Sunghyeon Park, and In-Dong Kim. "Design of Wireless IoT System for Monitoring and Controlling DC Circuit Breaker." In 2023 26th International Conference on Electrical Machines and Systems (ICEMS). IEEE, 2023. http://dx.doi.org/10.1109/icems59686.2023.10345097.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Li, Tian-Hui, Chun-en Fang, Wei Li, and Li-li Zhou. "Investigation on Controlling Techniques of Moving Contact Behaviors for Vacuum Circuit Breaker Based on Fuzzy Control." In 2010 Asia-Pacific Power and Energy Engineering Conference. IEEE, 2010. http://dx.doi.org/10.1109/appeec.2010.5448251.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Fu-cheng, Lang, and Zhang Hong-kui. "Design for measuring and controlling system of synthetic test for high voltage circuit breaker based on DSP." In 2016 Chinese Control and Decision Conference (CCDC). IEEE, 2016. http://dx.doi.org/10.1109/ccdc.2016.7531830.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Moradi, Mojtaba, and Michael R Konopczynski. "The New Flow Control Devices Autonomously Controlling the Performance of Matrix Acid Stimulation Operations in Carbonate Reservoirs." In SPE Annual Technical Conference and Exhibition. SPE, 2021. http://dx.doi.org/10.2118/205975-ms.

Full text
Abstract:
Abstract Matrix acidizing is a common but complex stimulation treatment that could significantly improve production/injection rate, particularly in carbonate reservoirs. However, the desired improvement in all zones of the well by such operation may not be achieved due to existing and/or developing reservoir heterogeneity. This paper describes how a new flow control device (FCD) previously used to control water injection in long horizontal wells can also be used to improve the conformance of acid stimulation in carbonate reservoirs. Acid stimulation of a carbonate reservoir is a positive feedback process. Acid preferentially takes the least resistant path, an area with higher permeability or low skin. Once acid reacts with the formation, the injectivity in that zone increases, resulting in further preferential injection in the stimulated zone. Over-treating a high permeability zone results in poor distribution of acid to low permeability zones. Mechanical, chemical or foam diversions have been used to improve stimulation conformance along the wellbore, however, they may fail in carbonate reservoirs with natural fractures where fracture injectivity dominates the stimulation process. A new FCD has been developed to autonomously control flow and provide mechanical diversion during matrix stimulation. Once a predefined upper limit flowrate is reached at a zone, the valve autonomously closes. This eliminates the impact of thief zone on acid injection conformance and maintains a prescribed acid distribution. Like other FCDs, this device is installed in several compartments in the wells. The device has two operating conditions, one, as a passive outflow control valve, and two, as a barrier when the flow rate through the valve exceeds a designed limit, analogous to an electrical circuit breaker. Once a zone has been sufficiently stimulated by the acid and the injection rate in that zone exceeds the device trip point, the device in that zone closes and restricts further stimulation. Acid can then flow to and stimulate other zones This process can be repeated later in well life to re-stimulate zones. This performance enables the operators to minimise the impacts of high permeability zones on the acid conformance and to autonomously react to a dynamic change in reservoirs properties, specifically the growth of wormholes. The device can be installed as part of lower completions in both injection and production wells. It can be retrofitted in existing completions or be used in a retrievable completion. This technology allows repeat stimulation of carbonate reservoirs, providing mechanical diversion without the need for coiled tubing or other complex intervention. This paper will briefly present an overview of the device performance, flow loop testing and some results from numerical modelling. The paper also discusses the completion design workflow in carbonates reservoirs.
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!

To the bibliography