To see the other types of publications on this topic, follow the link: Clamping technique.

Journal articles on the topic 'Clamping technique'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 50 journal articles for your research on the topic 'Clamping technique.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse journal articles on a wide variety of disciplines and organise your bibliography correctly.

1

Chaib, Eleazar, William Abrão Saad, Ikurou Fujimura, Willian Abrão Saad Jr., and Joaquim Gama-Rodrigues. "The main indications and techniques for vascular exclusion of the liver." Arquivos de Gastroenterologia 40, no. 2 (2003): 131–36. http://dx.doi.org/10.1590/s0004-28032003000200013.

Full text
Abstract:
BACKGROUND: The purpose of vascular clamping during the course of liver resection is to reduce bleeding and subsequent complications. AIM: To show both step-by-step surgical techniques for vascular exclusion of the liver and their indications. METHODS: It is described the following techniques: clamping of the hepatic pedicle, ''Pringle'' maneuver; intermittent clamping of the hepatic pedicle; intermittent vascular exclusion of the liver, without vena cava clamping, and hepatic vascular exclusion with vena cava clamping. Also metabolic and homodynamic consequences as well as the technical failu
APA, Harvard, Vancouver, ISO, and other styles
2

Wu, Long, A. M. Wang, P. H. Ren, and D. X. Li. "An improved technique of clamping method for keeping coaxiality precision of rotating frame." MATEC Web of Conferences 189 (2018): 05005. http://dx.doi.org/10.1051/matecconf/201818905005.

Full text
Abstract:
In order to ensure the concentricity accuracy of frame-like thinwalled parts, this paper takes the rotating frame as a machining example. And using the method of finite element simulation and calculation, this paper analyzes the main factors that cause the error of coaxiality of the rotating frame. Because the clamping force of the clamping device causes the deformation of the workpiece, this article is based on the finite element simulation to improve the clamping method. By adding a fixing block at the bottom of the frame and clamping with the fixing block to avoid direct pressure on the rot
APA, Harvard, Vancouver, ISO, and other styles
3

Harley, O. J. H., and T. F. Browne. "A Technique for Clamping Calcified Iliac Arteries." EJVES Extra 5, no. 1 (2003): 9–10. http://dx.doi.org/10.1016/s1533-3167(03)00013-x.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Janardanan, S., M. Rifat, and K. Patil. "Current Zero clamping technique during radical cystectomy." Annals of The Royal College of Surgeons of England 102, no. 7 (2020): 545–46. http://dx.doi.org/10.1308/rcsann.2020.0028.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Fernandez-Chiappe, Florencia, and Nara I. Muraro. "Patch-Clamping Fly Brain Neurons." Cold Spring Harbor Protocols 2022, no. 8 (2022): pdb.top107796. http://dx.doi.org/10.1101/pdb.top107796.

Full text
Abstract:
The membrane potential of excitable cells, such as neurons and muscle cells, experiences a rich repertoire of dynamic changes mediated by an array of ligand- and voltage-gated ion channels. Central neurons, in particular, are fantastic computators of information, sensing, and integrating multiple subthreshold currents mediated by synaptic inputs and translating them into action potential patterns. Electrophysiology comprises a group of techniques that allow the direct measurement of electrical signals. There are many different electrophysiological approaches, but, because Drosophila neurons ar
APA, Harvard, Vancouver, ISO, and other styles
6

Bhukya, Ravikumar, and P. Satish Kumar. "Modeling, Analysis and Comparative of Down Sampling based Clamping SV PWM for Cascaded and Diode Clamped Multilevel Inverter fed Induction Motor Drive." Indonesian Journal of Electrical Engineering and Computer Science 7, no. 3 (2017): 698. http://dx.doi.org/10.11591/ijeecs.v7.i3.pp698-707.

Full text
Abstract:
This paper presents investigation and performance analysis of novel down sampling based clamping SV PWM technique for diode and cascaded Multi-level Invereter fed to Induction motor drive. A novel down sampling based clamping SVPWM has developed by adding triangular off set to sinusoidal fundamental waveform is modified by down sampling the reference wave by order of 10 so this technique is called clamping space vector pulse width modulation techniques such as PD, POD and APOD. so as to shift the lower order harmonics to higher order side. This novel carrier is compared with the offset injecte
APA, Harvard, Vancouver, ISO, and other styles
7

Mosoyan, M. S., S. K. Al-Shukri, D. Y. Semenov, A. M. Essaian, and D. M. Ilin. "SELECTIVE PARENCHYMA CLAMPING TECHNIQUE AS AN ALTERNATIVE TO TRADITIONAL VASCULAR CLAMPING DURING PARTIAL NEPHRECTOMY." Herald Urology, no. 3 (September 20, 2014): 3–11. http://dx.doi.org/10.21886/2308-6424-2014-0-3-3-11.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Demuro, Angelo, and Ian Parker. "“Optical Patch-clamping”." Journal of General Physiology 126, no. 3 (2005): 179–92. http://dx.doi.org/10.1085/jgp.200509331.

Full text
Abstract:
We describe an optical technique using total internal reflection fluorescence (TIRF) microscopy to obtain simultaneous and independent recordings from numerous ion channels via imaging of single-channel Ca2+ flux. Muscle nicotinic acetylcholine (ACh) receptors made up of αβγδ subunits were expressed in Xenopus oocytes, and single channel Ca2+ fluorescence transients (SCCaFTs) were imaged using a fast (500 fps) electron-multiplied c.c.d. camera with fluo-4 as the indicator. Consistent with their arising through openings of individual nicotinic channels, SCCaFTs were seen only when a nicotinic a
APA, Harvard, Vancouver, ISO, and other styles
9

Yoh, Tomoaki, François Cauchy, and Olivier Soubrane. "Extracorporeal clamping technique using a dedicated vascular clamp." ASVIDE 6 (December 2019): 333. http://dx.doi.org/10.21037/asvide.2019.333.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Bagul, A., NR Brook, SJF Harper, and ML Nicholson. "Vascular Clamping of Calcified Vessels: The Peanut Technique." Annals of The Royal College of Surgeons of England 88, no. 1 (2006): 77. http://dx.doi.org/10.1308/rcsann.2006.88.1.77a.

Full text
APA, Harvard, Vancouver, ISO, and other styles
11

Lu, Dong, Jian Feng Li, Jie Sun, and Bo Xin. "Optimization of the Clamping Scheme of the Aero Monolithic Component Based on Even-Bedded Residual Stress Distribution." Materials Science Forum 532-533 (December 2006): 757–60. http://dx.doi.org/10.4028/www.scientific.net/msf.532-533.757.

Full text
Abstract:
Uneven distribution of the residual stress is the main factor causing the distortion of a workpiece. Different clamping scheme may cause different clamping stress. Clamping stress coupling with the residual stress inside the part induces different stress distribution, which affects components’ machining distortion and service life. To reflect the relationship between clamps and residual stress , finite element model with different clamping schemes were bulit and the clamping process was simulated. And the chip removal effect was taken into account using a material removal approach based on ele
APA, Harvard, Vancouver, ISO, and other styles
12

Mejean, Arnaud, Benoit Vogt, Sebastien Cazin, Chant Balian, Nicolas Thiounn, and Bertrand Dufour. "Selective Renal Parenchymal Clamping (SRPC) : a technique for nephron sparing surgery without clamping the pedicle." European Urology Supplements 1, no. 1 (2002): 26. http://dx.doi.org/10.1016/s1569-9056(02)80093-8.

Full text
APA, Harvard, Vancouver, ISO, and other styles
13

Unangst, Alicia M., Paul M. Ryan, Mitchell Harris, and Daniel Song. "Efficacy of the Glidepath Technique for Ankle Syndesmosis Reduction." Foot & Ankle Orthopaedics 5, no. 4 (2020): 2473011420S0047. http://dx.doi.org/10.1177/2473011420s00472.

Full text
Abstract:
Category: Ankle; Trauma Introduction/Purpose: Syndesmotic screw fixation is frequently required in rotational ankle injuries. Fibular malreduction after syndesmotic screw fixation occurs in as many as 52% of cases, which has been shown to detrimentally affect subjective outcomes and increase the probability of developing arthritis. The glidepath technique has been proposed as a useful technique to prevent malreduction. We hypothesize that the glidepath technique reduces the occurrence of fibular malreduction and results in improved outcomes compared to clamping. Methods: A retrospective cohort
APA, Harvard, Vancouver, ISO, and other styles
14

Abou-Al-Shaar, Hussam, Khaled J. Zaza, Muhammad Anees Sharif, and Samer Koussayer. "Repair of Thoracoabdominal Aortic Aneurysm with Thrombosed Infrarenal Component: A Modified Hybrid Technique without Aortic Cross Clamping." Case Reports in Medicine 2017 (2017): 1–6. http://dx.doi.org/10.1155/2017/7432032.

Full text
Abstract:
The authors report the successful repair of a Crawford type III thoracoabdominal aortic aneurysm (TAAA) with a thrombosed infrarenal component using a modified hybrid technique without aortic clamping in a high-risk patient. A 64-year-old male with a history of hypertension, diabetes, and severe chronic obstructive pulmonary disease presented with acute on chronic backache and bilateral short distance claudication. A computerized tomography scan demonstrated a large, nonleaking Crawford type III TAAA with thrombosed infrarenal component of the aneurysm. In addition, both common iliac arteries
APA, Harvard, Vancouver, ISO, and other styles
15

Yalavarthi, Amarnath, and Akbar Ahmad. "Analytical Modelling and Verification of Bus-Clamping Modulation Technique for Switched-Capacitor Converter." Modelling and Simulation in Engineering 2017 (2017): 1–10. http://dx.doi.org/10.1155/2017/6261404.

Full text
Abstract:
Space vector modulation techniques have advantages of high output voltages and reduced harmonic content as they utilize the dc bus effectively. Bus-clamped pulse width modulation classified in space vector techniques has the ability to reduce the switching losses of the converter and has reduced harmonic distortion. This paper provides mathematical analysis for 60-degree bus-clamping strategy to obtain the complete closed-form solution for finding the harmonic coefficients using double Fourier integral expression. The effectiveness of the bus-clamped approach on switched capacitor based multil
APA, Harvard, Vancouver, ISO, and other styles
16

Pasternak, S., T. Stehle, and U. Heisel. "Flexibilität in der Mikrospanntechnik*/Flexibility in the micro clamp technique – Study of the flexibility of micro clamping technologies with regard to various workpiece and manufacturing process parameters." wt Werkstattstechnik online 105, no. 09 (2015): 640–46. http://dx.doi.org/10.37544/1436-4980-2015-09-82.

Full text
Abstract:
In den vorherigen Fachartikeln zum Thema Mikrospannsysteme wurden experimentelle Untersuchungen an fünf Mikrospannverfahren – darunter das Spannen mit Eis, Wachs, Klebstoff, Vakuum und Spannbacken – hinsichtlich der mit ihnen erreichbaren Haltekräfte, Spannzeiten und Spannsteifigkeiten beschrieben. Der vorliegende 4. Fachbeitrag bezieht sich auf die Analyse der Flexibilität der erwähnten Spannverfahren hinsichtlich verschiedener Mikro- und Makrogeometrien sowie Werkstückwerkstoffe, eingesetzter Fertigungs-, Kühlschmierungs- und Positionierungsverfahren sowie der Bearbeitungsfreiheit und Automa
APA, Harvard, Vancouver, ISO, and other styles
17

Elmahdy, Ahmed, and Patricia Verleysen. "Challenges related to testing of composite materials at high strain rates using the split Hopkinson bar technique." EPJ Web of Conferences 183 (2018): 02021. http://dx.doi.org/10.1051/epjconf/201818302021.

Full text
Abstract:
The design of sample geometries and the measurement of small strains are considered the main challenges when testing composite materials at high strain rates using the split Hopkinson bar technique. The aim of this paper is to assess two types of tensile sample geometries, namely dog-bone and straight strip, in order to study the tensile behaviour of basalt fibre reinforced composites at high strain rates using the split Hopkinson bar technique. 2D Digital image correlation technique was used to study the distribution of the strain fields within the gauge section at quasi-static and dynamic st
APA, Harvard, Vancouver, ISO, and other styles
18

Yu, Hong Xia, and Chuang Li. "Bus-Clamping Based Improved Discrete Duty Ratio Control Technology of Direct Torque Control for Induction Motors." Applied Mechanics and Materials 541-542 (March 2014): 1177–84. http://dx.doi.org/10.4028/www.scientific.net/amm.541-542.1177.

Full text
Abstract:
One of the disadvantages of traditional direct torque control is high torque ripple, A method of reduce torque ripple was proposed basing bus-clamping and duty ratio control technique in this paper. Firstly, the switch vector table with bus-clamping technology was improved by analyzing the role of zero voltage vector to reduce torque ripple in different sector of voltage. Secondly, on the base of combing the improved bus-clamping direct torque control (BCDTC) and discrete duty ratio control (DDRC), a new switch vector table with discrete duty ratio and bus clamping was designed by analyzing th
APA, Harvard, Vancouver, ISO, and other styles
19

Krivoshchekov, Ye V., A. Yu Podoksenov, A. A. Lezhnev, et al. "Interventions on atrial septum under cardiopulmonary bypass and without aortic crossclamping." Patologiya krovoobrashcheniya i kardiokhirurgiya 16, no. 1 (2018): 71. http://dx.doi.org/10.21688/1681-3472-2012-1-71-74.

Full text
Abstract:
The study centered on the possibility of surgery on the atrial septum (AS) without aortic clamping and cardiac arrest. We compared two groups of patients who underwent intervention on AS as the major or concomitant stage of surgical treatment. Nineteen patients were assigned to the main group; they were operated under CPB without aortic clamping and cardioplegia. The control group consisted of 20 patients, whose AS was surgically treated by using a standard technique with aortic occlusion. The groups were comparable by age and disease. The patients of both groups withstood the surgical interve
APA, Harvard, Vancouver, ISO, and other styles
20

Marin, Rodrigo A., and Placid M. Ferreira. "Optimal Placement of Fixture Clamps: Minimizing the Maximum Clamping Forces." Journal of Manufacturing Science and Engineering 124, no. 3 (2002): 686–94. http://dx.doi.org/10.1115/1.1469520.

Full text
Abstract:
This paper addresses the problem of synthesizing robust optimal clamping schemes on three-dimensional parts with planar faces, with and without friction. Given a work part with a pre-defined deterministic 3-2-1 location scheme, a set of polygonal convex regions on its faces are defined as areas of admissible clamp positions. A known set of external disturbing wrenches is also given. The frictionless case is considered first, and a new linear program is formulated to provide clamp locations that minimize the maximum clamping force. A transformation of the solution is presented that permits the
APA, Harvard, Vancouver, ISO, and other styles
21

Chen, Xue, Ming Zhe Li, Zhong Yi Cai, and Wen Zhi Fu. "Effect of Different Clamping Modes on Dimples of Sheet Metal Parts in Multi-Point Stretch Forming." Applied Mechanics and Materials 44-47 (December 2010): 2326–30. http://dx.doi.org/10.4028/www.scientific.net/amm.44-47.2326.

Full text
Abstract:
Dimples are a typical defect in multi-point stretch forming (MPSF) of sheet metal. Comparison on the numerical simulation of the spherical parts in MPSF with traditional and flexible clamping modes were done, the effects of transition zone length and elastic cushion on the dimples of the spherical parts were studied. The results show that thickness strain of the forming parts using traditional clamping mode is greater than that using flexible clamping mode under the same forming conditions, so the dimpling depth of the former is relatively deeper than that of the latter. With the increasing tr
APA, Harvard, Vancouver, ISO, and other styles
22

Fernandez-Chiappe, Florencia, and Nara I. Muraro. "Patch-Clamping Drosophila Brain Neurons." Cold Spring Harbor Protocols 2022, no. 8 (2022): pdb.prot107936. http://dx.doi.org/10.1101/pdb.prot107936.

Full text
Abstract:
Drosophila melanogaster is widely used as a model organism in all fields of biomedical research. In neuroscience, vast amounts of information have been gained using this little fly including the identification of neuronal circuits that regulate behaviors, the unraveling of their genetic underpinnings, and the molecular mechanisms involved. With plenty of genetic tools available to manipulate and infer neuronal activity, the direct measurement of electrical properties of fly neurons has lagged behind. This is due to the intricacies of performing electrical recordings in small cells such as fly
APA, Harvard, Vancouver, ISO, and other styles
23

KHIR, Ashraf W., Michael Y. HENEIN, Tat KOH, Saroj K. DAS, Kim H. PARKER, and Derek G. GIBSON. "Arterial waves in humans during peripheral vascular surgery." Clinical Science 101, no. 6 (2001): 749–57. http://dx.doi.org/10.1042/cs1010749.

Full text
Abstract:
The purpose of this study was to investigate the effect of aortic clamping on arterial waves during peripheral vascular surgery. We measured pressure and velocity simultaneously in the ascending aorta, in ten patients (70±5 years) with aortic-iliac disease intra-operatively. Pressure was measured using a catheter tip manometer, and velocity was measured using Doppler ultrasound. Data were collected before aortic clamping, during aortic clamping and after unclamping. Hydraulic work in the aortic root was calculated from the measured data, the reflected waves were determined by wave-intensity an
APA, Harvard, Vancouver, ISO, and other styles
24

Belanger, Michael P., Nesime Askin, and Carin Wittnich. "Multiple In Vivo Liver Biopsies Using a Freeze-Clamping Technique." Journal of Investigative Surgery 15, no. 2 (2002): 109–12. http://dx.doi.org/10.1080/08941930290085859.

Full text
APA, Harvard, Vancouver, ISO, and other styles
25

Biglioli, Paolo, Rita Spirito, Massimo Porqueddu, et al. "Quick, simple clamping technique in descending thoracic aortic aneurysm repair." Annals of Thoracic Surgery 67, no. 4 (1999): 1038–43. http://dx.doi.org/10.1016/s0003-4975(99)00146-0.

Full text
APA, Harvard, Vancouver, ISO, and other styles
26

Desai, Chirag S., Raffaele Girlanda, Jason Hawksworth, and Thomas M. Fishbein. "Modified technique for aortic cross-clamping during liver donor procurement." Clinical Transplantation 28, no. 5 (2014): 611–15. http://dx.doi.org/10.1111/ctr.12360.

Full text
APA, Harvard, Vancouver, ISO, and other styles
27

Ito, Hideki, Shunei Saito, Ken Miyahara, et al. "Retrograde Cardioplegia Revisited: Open Technique for Long Aortic Cross Clamping." Heart, Lung and Circulation 22, no. 9 (2013): 742–45. http://dx.doi.org/10.1016/j.hlc.2013.03.002.

Full text
APA, Harvard, Vancouver, ISO, and other styles
28

Banu, Sufia, and Shweta Gupta. "Design and Leakage Power Optimization of 6T Static Random Access Memory Cell Using Cadence Virtuoso." International Journal of Electrical and Electronics Research 10, no. 2 (2022): 341–46. http://dx.doi.org/10.37391/ijeer.100246.

Full text
Abstract:
Reduction of Leakage power at nano meter regime has become a challenging factor for VLSI designers. This is owing to the need for low-power, battery-powered portable pads, high-end gadgets and various communication devices. Memories are made up of Static RAM and Dynamic RAM. SRAM has had a tremendous impact on the global VLSI industry and is preferred over DRAM because of its low read and write access time. This research study proposes a new method has been proposed of 6T Static Random Access Memory cell to decrease the leakage current at various technologies. Three source biasing methods are
APA, Harvard, Vancouver, ISO, and other styles
29

Chaari, Riadh, Moez Abennadher, Jamel Louati, and Mohamed Haddar. "Mathematical methodology for optimization of the clamping forces accounting for workpiece vibratory behaviour." International Journal for Simulation and Multidisciplinary Design Optimization 5 (2014): A13. http://dx.doi.org/10.1051/smdo/2013005.

Full text
Abstract:
This paper addresses the problem of determining the minimum clamping forces that ensure the dynamic fixturing stability. The clamping force optimization problem is formulated as a bi-level nonlinear programming problem and solved using a computational intelligence technique called particle swarm optimization (PSO). Indeed, we present an innovative simulation methodology that is able to study the effects of fixture-workpiece system dynamics and the continuously change due to material removal on fixturing stability and the minimum required clamping forces during machining. The dynamic behaviour
APA, Harvard, Vancouver, ISO, and other styles
30

Shlomin, V. V., M. L. Gordeev, P. B. Bondarenko, et al. "Use of the temporal bypass technique in the treatment of thoracic and thoracoabdominal aortic aneurysms." Grekov's Bulletin of Surgery 178, no. 3 (2019): 21–27. http://dx.doi.org/10.24884/0042-4625-2019-178-3-21-27.

Full text
Abstract:
The OBJECTIVE was to analyze the experience of using a vascular prosthesis as a temporary bypass for spinal cord and visceral organs ischemia prevention during the clamping time in surgical reconstruction of thoracic and thoracoabdominal aortic aneurysm.MATERIAL AND METHODS. The study included 60 patients with the pathology of aortic arch, descending and thoracoabdominal aorta (TAAA) from 1997 to 2018. Among them, 42 (11 %) patients were diagnosed with TAAA I–IV types according to E. S. Crawford classification, 18 (32 %) – with the aortic arch aneurysm and the descending thoracic aorta. Planne
APA, Harvard, Vancouver, ISO, and other styles
31

Wang, Zhengyu, Daoming Wang, Bing Chen, Lingtao Yu, Jun Qian, and Bin Zi. "A Clamping Force Estimation Method Based on a Joint Torque Disturbance Observer Using PSO-BPNN for Cable-Driven Surgical Robot End-Effectors." Sensors 19, no. 23 (2019): 5291. http://dx.doi.org/10.3390/s19235291.

Full text
Abstract:
The ability to sense external force is an important technique for force feedback, haptics and safe interaction control in minimally-invasive surgical robots (MISRs). Moreover, this ability plays a significant role in the restricting refined surgical operations. The wrist joints of surgical robot end-effectors are usually actuated by several long-distance wire cables. Its two forceps are each actuated by two cables. The scope of force sensing includes multidimensional external force and one-dimensional clamping force. This paper focuses on one-dimensional clamping force sensing method that do n
APA, Harvard, Vancouver, ISO, and other styles
32

Irsara, Sandro, Francesco Russo, and Luca Ferretto. "In Situ Treatment of Branch Renal Artery Aneurysms With Pantaloon Vein Graft." Vascular and Endovascular Surgery 54, no. 3 (2019): 272–77. http://dx.doi.org/10.1177/1538574419895372.

Full text
Abstract:
Introduction: The optimal method of operative management of complex renal artery aneurysms (RAAs) involving distal branches (BRAAs) remains unclear. When more than 1 artery is involved within the BRAA, endovascular techniques are not advisable and an ex vivo approach is often preferred. In this study, we introduce an alternative surgical in situ technique to treat BRAAs. Methods and Surgical Technique: Five aneurysms involving the main or second-order bifurcation of the renal artery (RA) were treated in 4 patients at our institute between November 2012 and January 2017. The treatment of the BR
APA, Harvard, Vancouver, ISO, and other styles
33

Joo, Geun Su, Min Kuk Choi, and Hoon Huh. "A Newly Developed Clamping Device for the Tension/Compression Test at Various Strain Rates." Key Engineering Materials 626 (August 2014): 353–58. http://dx.doi.org/10.4028/www.scientific.net/kem.626.353.

Full text
Abstract:
The tension/compression hardening behavior is important in sheet metal forming processes because of complicated loading paths. Experimental methods to measure the tension/ compression behavior have not considered the effect of the strain rate although the strain rate is related to the hardening behavior of sheet metal. The tension/compression tests need to be conducted considering the strain rate to acquire accurate hardening behavior.This paper deals with an experimental technique to measure the tension/compression behavior of sheet metal at various strain rates. A new clamping device was dev
APA, Harvard, Vancouver, ISO, and other styles
34

Shamanin, V. A., I. V. Karpov, E. E. Pisareva, N. I. Gutkina, and S. P. Kovalenko. "REQUIREMENTS FOR EFFICIENT PCR CLAMPING BY LOCKED NUCLEIC ACID OLIGONUCLEOTIES FOR SIMPLE AND SENSITIVE DETECTION OF SOMATIC MUTATIONS." Siberian journal of oncology 17, no. 4 (2018): 30–35. http://dx.doi.org/10.21294/1814-4861-2018-17-4-30-35.

Full text
Abstract:
PCR clamping/wild-type blocking PCR with non-extendable locked nucleic acid (LNA) oligonucleotides is used for sensitive detection of somatic mutations in tumors. Various versions of the technique use different DNA polymerases and LNA oligonucleotides with and without additional phosphorothioate modifications. Here we studied requirements for successful PCR clamping with LNA oligonucleotides and Taq DNA polymerase for analysis of mutations in KRAS and BRAF genes by means of real-time PCR and Sanger sequencing. We found that addition of phosphorothioate linkages at the 5’-end of LNA oligonucleo
APA, Harvard, Vancouver, ISO, and other styles
35

Redza, Mohd Ridhwan Mohammed, Yupiter H. P. Manurung, Robert Ngendang Ak. Lidam, et al. "Distortion Analysis on Multipassed Butt Weld Using FEM and Experimental Study." Advanced Materials Research 311-313 (August 2011): 811–14. http://dx.doi.org/10.4028/www.scientific.net/amr.311-313.811.

Full text
Abstract:
This paper investigates the simulation technique for analyzing the distortion behavior induced by welding process on welded plate which was clamped on one side. This clamping method is intended to enable the investigation of the maximum distortion on the other side. FEA software SYSWELD was employed to predict multipassed butt weld distortion of low carbon steel with thicknesses of 6 mm and 9 mm. The simulation begins with the development of model geometry and meshing type followed by suitable selection of heat source model represented by the Goldak’s double ellipsoid model. Other parameters s
APA, Harvard, Vancouver, ISO, and other styles
36

Ahmaniyah, Ahmaniyah, Kamilah Hidajati, and Ari Suwondo. "Pemerahan dan penundaan penjepitan tali pusat terhadap kadar hemoglobin bayi baru lahir." Jurnal Ners dan Kebidanan (Journal of Ners and Midwifery) 5, no. 3 (2018): 195–200. http://dx.doi.org/10.26699/jnk.v5i3.art.p195-200.

Full text
Abstract:
The incidence of iron deficiency anemia in term infants from 0-6 months is 40.8%. Efforts to reduce anemia in infants and toddlers is by ensuring the baby gets blood from the placenta through the umbilical cord. Labor occurs when oxygen shifts from the heart to the lungs 8-10% of the fetal period to 50% in neonates. Immediate cord clamping vascular resistance from the disconnected placenta which results in the increased of resistance of the baby's vascular system and eliminates about 1/4 of the volume of blood and iron in the neonate. The time of cutting the umbilical cord is a determining fac
APA, Harvard, Vancouver, ISO, and other styles
37

Kobayashi, Kimihiro, Tetsuro Uchida, Jun Hayashi, et al. "Simple Retrieval Technique of the Elephant Trunk by Partial Aortic Clamping." Heart, Lung and Circulation 30, no. 9 (2021): e95-e97. http://dx.doi.org/10.1016/j.hlc.2021.02.012.

Full text
APA, Harvard, Vancouver, ISO, and other styles
38

Noori, IbrahimFalih, and MansourAmin Mohammad. "Sutureless focus harmonic thyroidectomy versus conventional clamping and knot-tying technique." Medical Journal of Babylon 15, no. 4 (2018): 300. http://dx.doi.org/10.4103/mjbl.mjbl_45_18.

Full text
APA, Harvard, Vancouver, ISO, and other styles
39

Yeh, Chien-Hung, Hung-Chang Chien, Chien-Chung Lee, and Sien Chi. "Gain-clamping erbium-doped waveguide amplifier module using optical feedback technique." Optics Communications 246, no. 1-3 (2005): 73–77. http://dx.doi.org/10.1016/j.optcom.2004.10.053.

Full text
APA, Harvard, Vancouver, ISO, and other styles
40

Sell, P. J. "Direct pneumatic pressure in a clamping technique during strain gauge bonding." Strain 25, no. 1 (1989): 21–23. http://dx.doi.org/10.1111/j.1475-1305.1989.tb00682.x.

Full text
APA, Harvard, Vancouver, ISO, and other styles
41

Cagli, Kerim, Gokhan Lafci, and Omer Cicek. "An Alternative “No Resection” Technique for Posterior Mitral Leaflet Prolapse Repair: Reverse T-Plasty." Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery 9, no. 4 (2014): 334–36. http://dx.doi.org/10.1097/imi.0000000000000076.

Full text
Abstract:
Reverse T-plasty is an alternative “no resection” technique for posterior mitral leaflet prolapse repair that is inspired by butterfly resection. It combines mediolateral and anteroposterior plane foldings of the posterior leaflet without any resection and shortens cardiopulmonary bypass and cross-clamping time.
APA, Harvard, Vancouver, ISO, and other styles
42

Kwong, A. H. M., and K. A. Edge. "A method to reduce noise in hydraulic systems by optimizing pipe clamp locations." Proceedings of the Institution of Mechanical Engineers, Part I: Journal of Systems and Control Engineering 212, no. 4 (1998): 267–80. http://dx.doi.org/10.1243/0959651981539451.

Full text
Abstract:
This paper describes a novel technique to reduce noise and vibration in hydraulic systems. The approach involves finding the best hydraulic circuit mounting locations to avoid excessive coupling between the hydraulic pipes and the supporting structures. Using a well-developed transfer matrix method, the dynamic response to disturbance by fluid flow ripples can be predicted at all pipe locations. By making appropriate assumptions concerning the mounting impedance, the force and displacement parameters involved in clamping the pipes can be estimated. These results can be used to quantify the fit
APA, Harvard, Vancouver, ISO, and other styles
43

Hicks, R. G., D. R. Kerr, and D. A. Horton. "Thiopentone Cerebral Protection under EEG Control during Carotid Endarterectomy." Anaesthesia and Intensive Care 14, no. 1 (1986): 22–28. http://dx.doi.org/10.1177/0310057x8601400106.

Full text
Abstract:
Seventy patients who underwent a total of 77 consecutive carotid endarterectomies were given thiopentone (mean dose 19 mg/kg) under EEG control for cerebral protection during the period of carotid clamping. This technique was used instead of elective insertion of a temporary bypass shunt in response to adverse EEG changes occurring after clamping. The EEG was monitored continuously throughout operation. The EEG burst-suppression pattern with electrically inactive periods of 30-60 seconds was taken as indicating a depth of barbiturate anaesthesia adequate to provide brain protection. Patients e
APA, Harvard, Vancouver, ISO, and other styles
44

Jamali, Zara, Mahwish Fatima, Shagufta Yaqoob, et al. "Neonatal Outcomes in Cord Clamping; An Observational Study Highlighting the Correlation of Cord Clamping Time with Haematological Parameters." SOJ Gynecology , Obstetrics & Women's Health 4, no. 1 (2018): 1–5. http://dx.doi.org/10.15226/2381-2915/4/1/00134.

Full text
Abstract:
Objectives: The purpose of this study was to evaluate the neonatal outcomes in cord clamping and to find their correlation with different haematological parameters in neonates of Jinnah Postgraduate Medical Centre, Karachi Methodology: This was an observational study in which non-probability convenient sampling technique was used after taking ethical approval. The study was conducted on 342 pregnant women in the Obstetrics & Gynaecology ward of Jinnah Postgraduate Medical Centre, Karachi, from 1st July 2016 to 31st December 2016.All the pregnant women from age of 25 to 45 years and without
APA, Harvard, Vancouver, ISO, and other styles
45

Alhan, Cem, Şahin Şenay, Muharrem Koçyiğit, et al. "Robot-assisted mitral valve surgery without aortic cross-clamping: An alternative technique." Turkish Journal of Thoracic and Cardiovascular Surgery 29, no. 3 (2021): 415–16. http://dx.doi.org/10.5606/tgkdc.dergisi.2021.21497.

Full text
APA, Harvard, Vancouver, ISO, and other styles
46

Lin, B. R., and J. J. Chen. "Analysis of an integrated flyback and zeta converter with active clamping technique." IET Power Electronics 2, no. 4 (2009): 355–63. http://dx.doi.org/10.1049/iet-pel.2008.0038.

Full text
APA, Harvard, Vancouver, ISO, and other styles
47

A. Probst, D. Palmes, H. Freise, M. "A New Clamping Technique for Biomechanical Testing of Tendons in Small Animals." Journal of Investigative Surgery 13, no. 6 (2000): 313–18. http://dx.doi.org/10.1080/089419300750059352.

Full text
APA, Harvard, Vancouver, ISO, and other styles
48

Vuong, N.-S., C. Michiels, Y. Grassano, et al. "V45 Benefit of the superselective clamping technique for multiple robot assisted tumorectomies." European Urology Supplements 15, no. 3 (2016): eV45. http://dx.doi.org/10.1016/s1569-9056(16)61213-7.

Full text
APA, Harvard, Vancouver, ISO, and other styles
49

Liu, Zhen-Sheng, Long-Jiang Zhou, Yong Sun, Xiong-Wei Kuang, Jia-Xiang Wang, and Xin-Jiang Zhang. "Thrombectomy Using “Clamping Embolus with Semi-Retrieval” Technique in Acute Ischemic Stroke." Journal of Stroke and Cerebrovascular Diseases 27, no. 3 (2018): 733–39. http://dx.doi.org/10.1016/j.jstrokecerebrovasdis.2017.10.013.

Full text
APA, Harvard, Vancouver, ISO, and other styles
50

BIGLIOLI, P. "Descending thoracic aorta aneurysmectomy: left-left centrifugal pump versus simple clamping technique." Cardiovascular Surgery 3, no. 5 (1995): 511–18. http://dx.doi.org/10.1016/0967-2109(09)67210-c.

Full text
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!