To see the other types of publications on this topic, follow the link: Climatización.

Dissertations / Theses on the topic 'Climatización'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 46 dissertations / theses for your research on the topic 'Climatización.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.

1

Cuzca, Rondón Jhonn Robert. "Climatización de un bus interprovincial." Bachelor's thesis, Universidad Nacional Mayor de San Marcos, 2016. https://hdl.handle.net/20.500.12672/6320.

Full text
Abstract:
El documento digital no refiere un asesor
Publicación a texto completo no autorizada por el autor
Implementa un equipo de climatización de aire en el interior de un bus tipo turismo. Realiza el cálculo de las cargas de enfriamiento y calentamiento, tomando en cuenta todos los aspectos que intervienen en las ganancias de calor, siguiendo la norma ASHRAE para el tratamiento de aire y sus aplicaciones. También se explica la utilización y aplicación de las cartas psicométricas con el fin de determinar la potencia que los equipos deben tener para que los mismos trabajen en determinada locación. Posteriormente se indican todos los equipos con la capacidad necesaria para obtener un ambiente de comodidad, así como también el diseño de los ductos, la cantidad de material para su fabricación y el número de boquillas de salida totales necesarios para la distribución de aire tratado térmicamente en el interior del bus. Finalmente se da a conocer los costos involucrados para la implementación de los sistemas de climatización en el bus.
Trabajo de suficiencia profesional
APA, Harvard, Vancouver, ISO, and other styles
2

Benavides, Alvarez Carlos Augusto. "Sistema de climatización oficinas de Ingelmec." Bachelor's thesis, Universidad Nacional Mayor de San Marcos, 2016. https://hdl.handle.net/20.500.12672/6230.

Full text
Abstract:
Publicación a texto completo no autorizada por el autor
Realiza el diseño del sistema de aire acondicionado, mediante el sistema de Volumen de Refrigerante Variable llegando a brindar confort térmico a los trabajadores y personas que harán del uso de las instalaciones de las oficinas. Determina la carga térmica de cada ambiente mediante el método de temperatura equivalente. Calcula las dimensiones de los ductos de suministro de aire y las dimensiones de los difusores y rejillas de los equipos. Selecciona los principales equipos a utilizar de acuerdo a la arquitectura de las oficinas. Utiliza un software para la selección de los equipos de aire acondicionado.
Trabajo de suficiencia profesional
APA, Harvard, Vancouver, ISO, and other styles
3

Benavides, Alvarez Carlos Augusto, and Alvarez Carlos Augusto Benavides. "Sistema de climatización oficinas de Ingelmec." Bachelor's thesis, Universidad Nacional Mayor de San Marcos, 2016. http://cybertesis.unmsm.edu.pe/handle/cybertesis/6230.

Full text
Abstract:
Publicación a texto completo no autorizada por el autor
Realiza el diseño del sistema de aire acondicionado, mediante el sistema de Volumen de Refrigerante Variable llegando a brindar confort térmico a los trabajadores y personas que harán del uso de las instalaciones de las oficinas. Determina la carga térmica de cada ambiente mediante el método de temperatura equivalente. Calcula las dimensiones de los ductos de suministro de aire y las dimensiones de los difusores y rejillas de los equipos. Selecciona los principales equipos a utilizar de acuerdo a la arquitectura de las oficinas. Utiliza un software para la selección de los equipos de aire acondicionado.
Trabajo de suficiencia profesional
APA, Harvard, Vancouver, ISO, and other styles
4

Caballero, Zamorano Marlys Elizabeth. "Plan de negocios para empresa de climatización." Tesis, Universidad de Chile, 2019. http://repositorio.uchile.cl/handle/2250/170675.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Kutsuma, Ogata Martín Javier. "Diseño de un sistema de climatización en aula CAD-CAE." Bachelor's thesis, Pontificia Universidad Católica del Perú, 2011. http://tesis.pucp.edu.pe/repositorio/handle/123456789/865.

Full text
Abstract:
El presente trabajo tuvo como finalidad proponer un sistema de climatización de aire, con el fin de mejorar las condiciones de trabajo en el Laboratorio CAD-CAE y los espacios contiguos (INACOM y oficina). Para esto se analizaron las condiciones previas a la instalación del sistema, recopilándose información trascendente, como las condiciones climáticas. Posteriormente, se establecieron las condiciones ideales, para luego especificar las condiciones que deseadas en el lugar. En el segundo capítulo se refiere a la evaluación de cargas térmicas. Se obtuvo que el 42% de la carga térmica se debe a la fenestración, el 36% por cargas internas, el 8% de la carga es transferida del exterior por las superficies, el 9% se debe a la carga de ventilación y por último el 5% es por infiltración de aire al ambiente acondicionado. Luego en la segunda parte del capítulo, se determinó que es necesario un equipo que extraiga 22.37kW de carga de enfriamiento del laboratorio, 5.22kW del INACOM y 6.29kW de la oficina. Además este debe renovar el aire con una frecuencia de 1.34m3/s en el laboratorio, 0.4 m3/s y 0.6 m3/s en el INACOM y la oficina respectivamente. En el tercer capítulo se seleccionaron los equipos de acuerdo a lo establecido en el capítulo anterior, empleándose manuales, así como catálogos e información complementaria que permita la adecuada selección del equipamiento. Finalmente detallo una evaluación económica referente al costo del sistema seleccionado (US$14,296.70 inc. IGV) y se estableció una comparación con el equipo actual que funciona en dicho establecimiento el cual está sobredimensionado según la capacidad de sus equipos.
Tesis
APA, Harvard, Vancouver, ISO, and other styles
6

Trebilcock, Gac Javiera, and Grassi Ximena Fernández. "Desarrollo de línea de climatización segmento doméstico para FT Chile." Tesis, Universidad de Chile, 2016. http://repositorio.uchile.cl/handle/2250/143266.

Full text
Abstract:
TESIS PARA OPTAR AL GRADO DE MAGÍSTER EN ADMINISTRACIÓN Javiera Trebilcock Gac [Parte I], Ximena Fernández Grassi [Parte II]
El uso del aire acondicionado en Chile es una tendencia que va en aumento. En el año 2010 menos del 1% de las viviendas chilenas usaban aire acondicionado. Sin embargo, se estima que en el año 2022 cerca del 3% aproximado del total de hogares del país ocuparán esta opción de climatización, lo que representará un total de cerca de 350.000 equipos instalados. Varios factores explican este crecimiento de la demanda:  El cambio climático que estamos experimentando;  El incremento en los niveles de polución ambiental y la mayor concientización que la población está teniendo respecto al cuidado del medio ambiente y a la seguridad, que nos hace buscar opciones más amigables con el medio ambiente y más seguras con quienes las usan.  Un mayor interés por incrementar el nivel de confort térmico en los hogares y el ahorro energético.  Una “cultura de la climatización” que está acercando cada vez más a las personas, la opción de climatizar los hogares con aire acondicionado. El proyecto se realizará por etapas, iniciando en la zona centro de Chile, que abarca la Región Metropolitana, Valparaíso y O’Higgins, para luego seguir penetrando en las demás regiones de Chile a través de una red de distribuidores exclusivos localizados en cada una de ellas. Su expansión se realizará a través de una red de instaladores y distribuidores fidelizados y formados por la compañía que llegarán en forma directa al usuario final. Este canal instalador, potenciado por la calidad de nuestros productos, el know-how de la compañía y la calidad de nuestro servicio técnico, sumado a la creación de esta cultura de la climatización, serán los pilares de esta propuesta. Este proyecto puro es rentable para la compañía con un Valor Actual Neto de CLP 967.791.815 y un Periodo de Recuperación de tres años. La Tasa Interna de Retorno será de 75%, una vez descontados los flujos. Se espera obtener ingresos por CLP 3.112.223.725 al sexto año, y un EBITDA de CLP 531.244.094
APA, Harvard, Vancouver, ISO, and other styles
7

Abarzúa, Lagos Guillermo Patricio. "Diseño de un Plan de Negocios para Nueva Empresa Importadora de Insumos de Ingeniería en Climatización." Tesis, Universidad de Chile, 2007. http://www.repositorio.uchile.cl/handle/2250/104577.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Rondón, Castillo Roberto. "Desarrollo de un Plan de Negocios: Empresa de Climatización Geotérmica Habitacional." Tesis, Universidad de Chile, 2007. http://www.repositorio.uchile.cl/handle/2250/104819.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Tirado, Cáceda Paul Miguel. "Sistema de climatización para el Hotel Libertador Cusco – Palacio del Inca." Bachelor's thesis, Universidad Nacional Mayor de San Marcos, 2013. https://hdl.handle.net/20.500.12672/14054.

Full text
Abstract:
Publicación a texto completo no autorizada por el autor
El documento digital no refiere asesor
Plantea el diseño de un sistema de climatización para un hotel, categoría cinco estrellas, ubicado en la ciudad del Cusco. Dicho hotel posee cuatro pisos y un sótano, dentro de él se encuentra ciento noventa y seis habitaciones, una sala de espera, una sala de estar, un bar, un salón principal con dos foyers (vestíbulos), seis salas de reuniones y un comedor con dos halls (vestíbulos). Previamente al desarrollo de esta monografía se establecen definiciones relacionadas con los sistemas de aire acondicionado, componentes y accesorios. A su vez se mencionan normas y recomendaciones a seguir para el diseño. El sistema de climatización planteado como solución brindara confort térmico que complementa el sistema de calefacción existente del hotel con un sistema de aire acondicionado de acuerdo a las recomendaciones del manual ASHRAE HVAC APLICATIONS 2007 Capitulo 5. Este proyecto contempla la instalación de dos enfriadores de agua (Chillers) tipo tornillo refrigerado por agua de 112 y 155 Toneladas de refrigeración, cada uno con su respectiva torre de enfriamiento y sistema de bombeo compuesto por dos bombas para cada chiller, que trabajaran alternadamente, ya que una de las bombas trabajara como respaldo de la otra ante alguna posible falla o mantenimiento de estos equipos. La particularidad del sistema propuesto es el uso de dos enfriados por agua (Chillers) tipo tornillo con flujo de refrigerante variable. De tal manera que se pueda cumplir con los requerimientos de confort para los distintos ambientes del hotel y a la vez se comprueba el ahorro energético y económico en comparación con los sistemas convencionales que utilizan chillers tipo scroll refrigerados por aire.
Trabajo de suficiencia profesional
APA, Harvard, Vancouver, ISO, and other styles
10

Mavila, Retamozo Homero. "Análisis energético de recuperación de calor en un sistema de climatización." Bachelor's thesis, Universidad Nacional Mayor de San Marcos, 2016. https://hdl.handle.net/20.500.12672/5512.

Full text
Abstract:
Publicación a texto completo no autorizada por el autor.
Tiene como objetivo evidenciar la necesidad, difundir y proponer mejoras en el ahorro energético para los sistemas de climatización en los edificios de oficinas del Perú mediante uso de recuperación de calor por aire de extracción. Puesto que, actualmente en la mayoría de casos se siguen proyectando sistemas de climatización convencionales en los cuales no se consideran estos sistemas y mecanismos los cuales nos llevarían a obtener menores consumos, a la vez que se contribuye con la reducción del impacto ambiental al reducir la emisiones de CO2. Con el análisis propuesto se obtienen como conclusiones las ventajas y desventajas del uso de estos sistemas y que protección se tienen para sistemas de climatización a futuro.
Trabajo de suficiencia profesional
APA, Harvard, Vancouver, ISO, and other styles
11

Lazarte, Lazarte Carlos Hugo. "Cálculo y selección del sistema de climatización para laboratorio veterinario – Agrofarma Internacional." Bachelor's thesis, Universidad Nacional Mayor de San Marcos, 2018. https://hdl.handle.net/20.500.12672/8465.

Full text
Abstract:
Realiza los cálculos y selección de partes y accesorios de sistema de climatización para controlar la calidad de aire, porque la climatización juega un papel muy importante en el proceso de almacenamiento de materia prima, fabricación, envasado y almacenamiento de producto terminado reduciendo al mínimo los riesgos de contaminación microbiológica por flujo cruzado. El cálculo de sistema de climatización se realiza analizando la lógica de funcionamiento del laboratorio partiendo de la clasificación de cada sala para brindar confort térmico en zonas de actividad estándar y en las zonas de salas limpias control de humedad, 50 +-5%, temperatura 23 +- 2°C, renovación de aire por hora según clasificación, cascada de presiones en todo el área de producción del laboratorio, filtración de alta calidad 99.99%, ruido del sistema en conjunto, control de velocidad de aire en los filtro terminales, rejillas y difusores. Indica las condiciones de diseño, localización, área del proyecto, condiciones interiores y exteriores del ambiente y análisis de los resultados de la carga térmica generada por diversos factores. Determina el costo de los equipos y accesorios.
Trabajo de suficiencia profesional
APA, Harvard, Vancouver, ISO, and other styles
12

Marincic, Irene. "Respuestas térmicas dinámicas en edificios: control térmico a través de la climatización natural." Doctoral thesis, Universitat Politècnica de Catalunya, 1999. http://hdl.handle.net/10803/6118.

Full text
Abstract:
Las estrategias de ahorro de energía en edificios, posibilitan la disminución de los costos de operación y/o mantenimiento de los mismos a lo largo de su vida útil. Sin embargo, el confort térmico de los usuarios se ve en muchos casos comprometido por políticas de ahorro energético, tanto en el diseño como en la operación de los edificios. Este ahorro de energía no deja de ser prioritario, pero no a costa del confort humano, ya que tarde o temprano este falso ahorro se revierte, debido a la falta de productividad en el trabajo o al deterioro de la salud de los ocupantes, además de un acondicionamiento indebido y al empleo de métodos poco eficaces.
Un compromiso entre ambas necesidades se puede alcanzar, o al menos aproximar, a través de pautas de diseño térmico elaboradas con criterios más precisos, a fin de lograr un ambiente confortable, evitando el sobre-dimensionamiento de materiales y energía. Uno de los problemas principales asociado al diseño orientado al ahorro de energía, o sistemas de climatización natural, es el de su control. Son necesarias estrategias de diseño para facilitar el control térmico de un modo más preciso, optimizando las condiciones de confort, los recursos materiales y la energía.
En la investigación se efectúa un análisis desde el punto de vista dinámico del comportamiento térmico de diferentes tipos de edificios, con el objeto de evaluar y comparar sus respuestas térmicas en relación con el clima exterior. Con base en datos experimentales de un cierto número de edificios, obtenidos a través de mediciones de variables ambientales, se pretende hallar una relación entre tipologías edificatorias, y la respuesta que se genera debido a las características de esta tipología. Se propone una metodología de evaluación global de los fenómenos y efectos térmicos que actúan sobre el edificio, utilizando un número reducido de variables y coeficientes, con una precisión razonable respecto a su simplicidad. Se obtiene una serie de parámetros de comportamiento dinámico, que caracterizan al sistema.
De la comparación de los sistemas térmicos, y bajo la hipótesis de que puede efectuarse una asociación inversa, pueden surgir indicaciones tanto de diseño como de control térmico para lograr determinados requisitos de confort térmico interior necesarios para la habitabilidad, aprovechando las propiedades de los materiales intervinientes y la geometría del proyecto arquitectónico.
El objetivo primordial de este trabajo es extraer información de las mediciones de edificios reales, para llegar a una conclusión sobre su comportamiento térmico, que se pueda extrapolar a otros edificios. Esto servirá de guía para una serie de pautas de diseño y control térmico. Esta metodología permitiría interactuar con el diseño arquitectónico, brindando ya sea una orientación en las decisiones de diseño o una verificación numérica que confirme la elección de determinados elementos. Se aspira a optimizar algunas pautas básicas de diseño de ciertos elementos y sistemas arquitectónicos, que puedan regular el clima interior y mantener un adecuado nivel de confort térmico, evitando un costoso sobredimensionamiento de los materiales constructivos y recursos energéticos. Persiguiendo estos objetivos, en el trabajo se logran las siguientes metas:
- Medición de algunas variables meteorológicas exteriores e interior a los edificios, que servirán como datos para el análisis de su comportamiento.
- Desarrollo de un modelo de cálculo que represente al edificio como sistema dinámico, en que intervengan variables fácilmente medibles, pero de efectos relevantes sobre la respuesta térmica.
- Identificación de elementos y sistemas arquitectónicos capaces de modificar (controlar) las condiciones climáticas interiores, en base al análisis efectuado del comportamiento térmico,
- Elaboración de una serie de indicaciones de diseño térmico, que puedan servir de guía para optimizar el control de las condiciones interiores.
Strategies for energy saving in buildings allow substantial decreases in buildings energy costs for operation and maintenance. Nevertheless, because of the application of energy saving criteria in design and building operation, users' thermal comfort goes in many cases to a second term. Energy saving is priority, but it is necessary to take also into account the humans thermal comfort, because of consequences such as low work productivity, detriment of human heath, wrong use of air conditioning systems and low efficiency in the applied methods.
A compromise between energy saving and thermal comfort can be achieved, or at least approached, applying more accurate thermal design criteria, in order to obtain more comfortable environments without over-dimensioning materials and energy in the project.
One of the main problems related to energy efficiency using thermal passive systems is the systems control. Design strategies for a more accurate thermal control are necessary to optimize thermal comfort, materials and energy resources.
In this study, a dynamic analysis of thermal behaviour of different buildings is carried out, in order to evaluate and to compare their thermal responses in relation to the outdoor climate. Using experimental data, obtained from thermal measurements of several buildings, the intention is to find a relation between building typologies and the thermal response due to these properties.
A methodology is proposed for global evaluation of thermal phenomena and effects acting on the building, using a reduced number of variables and coefficients, obtaining an acceptable accuracy in relation to its simplicity. Parameters of dynamic building behaviour are obtained, which characterize the thermal system.
From the comparison of thermal systems, under the hypothesis of an inverse association, design and thermal control strategies can be obtained, for the achievement of better indoor thermal conditions, taking advantage of materials thermal properties and the geometry of the architectural project.
The main purpose of the study is, based on real buildings measurements, to obtain information about their thermal behaviour, able to be extrapolated to other buildings. This is useful to develop design and thermal control guidelines. According to these purposes, the following scopes have been achieved:
- Measurement of meteorological outdoor and indoor building thermal variables,
- Development of a model representing the building as a dynamic system, using easy measurable variables with relevant effects on thermal response,
- Identification of architectural elements and systems able to modify (control) indoor climatic conditions, based on buildings thermal behaviour analysis,
- Development of thermal design guidelines, useful to optimize the control of indoor conditions.
APA, Harvard, Vancouver, ISO, and other styles
13

Gutiérrez, Giraldo Daniel. "Sistema de climatización para hotel cuatro estrellas ubicado en la ciudad de Lima." Bachelor's thesis, Pontificia Universidad Católica del Perú, 2009. http://tesis.pucp.edu.pe/repositorio/handle/123456789/574.

Full text
Abstract:
El presente proyecto plantea el diseño de un sistema de climatización para un hotel, categoría cuatro estrellas, ubicado en la ciudad de Lima. Dicho hotel posee once pisos y un sótano, dentro de él se encuentran sesenta y ocho habitaciones, una sala de espera, una sala de estar, un bar, un salón principal con dos foyers (vestíbulos), seis salas de reuniones y un comedor con dos halls (vestíbulos). Previamente al desarrollo del proyecto se establecen definiciones relacionadas con los sistemas de aire acondicionado, componentes y accesorios. A su vez se mencionan normas y recomendaciones a seguir para el diseño. El sistema de climatización planteado como solución brindará confort térmico a los huéspedes y personas que hagan uso de las áreas comunes y de servicio del hotel de acuerdo a las recomendaciones del manual ASHRAE HVAC APLICATIONS 2007 Capítulo 5. Este proyecto contempla la instalación de un chiller (enfriador de agua) tipo tornillo refrigerado por aire de 882.6 kW (252 Toneladas de refrigeración), el cual posee dos bombas en su circuito de bombeo. Ambas bombas son de la misma capacidad ya que trabajarán alternadamente, una de las bombas servirá como respaldo de la otra ante alguna falla. La particularidad del sistema propuesto es el uso de un chiller (enfriador de agua) tipo tornillo con flujo de refrigerante variable. De tal manera que se llega a cumplir con los requerimientos de confort para los distintos ambientes el hotel y a la vez se comprueba el ahorro que pueda lograrse en el monto de inversión comparado con los sistemas convencionales que utilizan chillers (enfriadores de agua) tipo scroll refrigerados por aire.
Tesis
APA, Harvard, Vancouver, ISO, and other styles
14

Azahuanche, Asmat Manuel Humberto. "Cálculo y diseño del sistema de climatización de áreas de producción en laboratorios farmacéuticos." Universidad Nacional de Ingeniería. Programa Cybertesis PERÚ, 2006. http://cybertesis.uni.edu.pe/uni/2006/azahuanche_am/html/index-frames.html.

Full text
APA, Harvard, Vancouver, ISO, and other styles
15

Romero, Juipa Ruberli. "Estudio técnico para la climatización del quirófano del Hospital César Garayar García de Iquitos." Bachelor's thesis, Universidad Nacional Mayor de San Marcos, 2016. https://hdl.handle.net/20.500.12672/12773.

Full text
Abstract:
El documento digital no refiere asesor
Diseña un sistema de climatización para el área de quirófano del Hospital Cesar Garayar García, localizado en la ciudad de Iquitos, con la finalidad de proporcionar las condiciones necesarias, exigidas por las normativas peruanas. Calcula la carga térmica y caudal de equipo de aire acondicionado y capacidad del extractor de aire para mantener una presión positiva en las áreas a acondicionar y así evitar la infiltración de aire. Selecciona el equipo de aire acondicionado y extractor de aire de acuerdo a las necesidades de la sala de quirófanos. Calcula las pérdidas de presión en el sistema y dimensionamiento de toda la red de ductos.
Trabajo de suficiencia profesional
APA, Harvard, Vancouver, ISO, and other styles
16

Ruiz, Calvo Félix. "Análisis y modelado de una instalación geotérmica para climatización de un conjunto de oficinas." Doctoral thesis, Universitat Politècnica de València, 2015. http://hdl.handle.net/10251/54134.

Full text
Abstract:
[EN] The use of ground source heat pump systems has spread during the last years. When designing, studying and optimizing this kind of systems, models are used, more or less detailed, which allow predicting the behavior of the system within the application minimum requirements. The installation studied in this thesis is located at Universitat Politècnica de València. In this report, the development of a global detailed model of this installation is presented, along with its validation using experimental data. The main objective is to obtain a model able to correctly predict the dynamic and static behavior of the system, both on a short- and a long-term basis. Prior to the model development, it is necessary to study the performance of the experimental system. Besides the system description, also an analysis of the performance of the installation during five years (from 2008 to 2012) is carried out. For this analysis, some characteristic parameters of the system behavior have been taken into account which are obtained from the experimental measurements corresponding to the typical operation of the installation, such as the average water temperatures, the building's thermal load, the partial load ratio, or the daily and seasonal performance factors. Since the study and analysis of these parameters is one of the aims of the present work, the calculation procedure and the formulas used for their determination are detailed, in some cases involving a highly complex raw data processing. From the short-term evolution study of the variables that represent the performance of the installation, the main characteristics of the system dynamic behavior are identified. The model will intend to reproduce these characteristics. On the other hand, the long-term performance parameters are studied as monthly averages. In this analysis, the characteristic trends of the system long-term performance are identified. The model should be able to also reproduce these trends. The global model has been developed using the TRNSYS software. A progressive incorporation strategy has been followed. At each step, the correct adjustment of the model is ensured by validating it with experimental data, allowing the identification of the influence that each component has on the final results. When including the ground source heat exchanger to the global model, it is evident the need for a new model for this component that can correctly reproduce both the dynamic and static response of the water temperature at the end of the pipes of the heat exchanger. Therefore, as a final step, a new ground source heat exchanger model has been developed, based on combining two different models: the g-function model in order to account for the long-term behavior of the ground temperature, and the B2G model, specifically developed for this application. The ground source heat exchanger model has been validated against experimental data from two different installations and, finally, it has been included into the global model of the system. The system global model developed has proved to be able to precisely reproduce the experimental results for the system performance, both on a short- and long-term basis, even after including the modifications that have occurred on the experimental installation along the years. Therefore, the model will be a useful tool for the development of future optimization strategies, together with the corresponding control algorithms.
[ES] En los últimos años se han extendido las instalaciones de climatización con bomba de calor acoplada al terreno. En el diseño, el estudio y la optimización de este tipo de instalaciones se utilizan modelos con mayor o menor nivel de detalle que permiten predecir el comportamiento del sistema dentro de unos requerimientos mínimos específicos de la aplicación en concreto. La instalación objeto de estudio de la presente tesis se encuentra situada en la Universitat Politècnica de València. A lo largo de esta memoria se presenta el trabajo de desarrollo de un modelo global detallado de esta instalación, así como su validación con datos experimentales. El objetivo perseguido es el de obtener un modelo capaz de predecir correctamente el comportamiento dinámico y estático de la instalación, tanto a corto como a largo plazo. Previo al desarrollo del modelo en sí, es necesario estudiar el comportamiento de la instalación experimental. Además de una descripción detallada del sistema, se realiza un análisis de su funcionamiento a lo largo de varios años (del año 2008 al 2012). Para este análisis se han tenido en cuenta diversos parámetros característicos del comportamiento energético del sistema, obtenidos a partir de las medidas experimentales registradas en el funcionamiento habitual de la instalación. Uno de los objetivos de esta tesis es precisamente el estudio y análisis de estos parámetros, por lo que se han detallado las fórmulas y el procedimiento de cálculo utilizado para su obtención, que en algunos casos puede presentar una gran complejidad en el manejo y tratamiento de los datos experimentales. A partir del estudio de la evolución a corto plazo de las variables representativas del funcionamiento de la instalación, se identifican las principales características del comportamiento dinámico del sistema, que se intentarán reproducir con el modelo desarrollado. Por su parte, el estudio de los parámetros característicos del funcionamiento a lo largo de varios años se realiza teniendo en cuenta los valores correspondientes a promedios mensuales. En este análisis se identifican también las tendencias características del comportamiento del sistema a largo plazo, que posteriormente el modelo global de la instalación deberá ser capaz de reproducir. El modelo global se ha desarrollado utilizando la herramienta TRNSYS. Para ello se ha seguido una estrategia de incorporación progresiva de componentes. En cada paso se asegura un correcto ajuste del modelo mediante su validación con datos experimentales, lo cual permite identificar y aislar los efectos de cada componente sobre los resultados finales. Al incluir el intercambiador enterrado en el modelo global, queda patente la necesidad de un nuevo modelo de intercambiador enterrado capaz de reproducir el comportamiento tanto dinámico como estático de la temperatura del agua a la salida del mismo. Así pues, como último punto de la tesis, se ha desarrollado un modelo de intercambiador enterrado, basado en la combinación de dos modelos distintos: el modelo \emph{g-function} para tener en cuenta el comportamiento a largo plazo de la temperatura del terreno y el modelo B2G, desarrollado específicamente para esta aplicación. Este modelo de intercambiador enterrado ha sido debidamente validado con datos experimentales pertenecientes a dos intercambiadores distintos y, posteriormente, se ha incluido en el modelo global de la instalación. El modelo global de la instalación desarrollado de esta forma consigue reproducir con precisión los resultados experimentales del funcionamiento del sistema tanto a corto como a largo plazo, incluso después de aplicar las mismas modificaciones que se han ido aplicando a la instalación experimental a lo largo de los años, y resulta ser, por tanto, una herramienta útil para el desarrollo de futuras estrategias de optimización energética, junto con los algoritmos de control correspondientes.
[CAT] Als últims anys s'han estès les instal·lacions de climatització amb bomba de calor acoplada al terreny. En el disseny, l'estudi i la optimització d'aquest tipus d'instal·lacions s'utilitzen models amb major o menor nivell de detall que permeten predir el comportament del sistema dins uns requeriments mínims específics de l'aplicació en concret. La instal·lació objecte d'estudi de la present tesi es troba a la Universitat Politècnica de València. Al llarg d'aquesta memòria es presenta el treball de desenvolupament d'un model global detallat d'aquesta instal·lació, així com la seua validació amb dades experimentals. L'objectiu perseguit es el d'obtindre un model capaç de predir correctament el comportament dinàmic i estàtic de la instal·lació, tant a curt com a llarg termini. Prèviament al desenvolupament del model en sí, es necessari estudiar el comportament de la instal·lació experimental. A més de una descripció detallada del sistema, es realitza un anàlisi del seu funcionament al llarg de diversos anys (de l'any 2008 al 2012). Per a aquest anàlisi s'han considerat diversos paràmetres característics del comportament energètic del sistema, obtinguts a partir de les mesures experimentals registrades en el funcionament habitual de la instal·lació, com per exemple les temperatures mitjanes de l'aigua en diversos punts del sistema, la demanda tèrmica de l'edifici, el factor de càrrega parcial o els factors de rendiment diari i estacional. Un dels objectius d'aquesta tesi és precisament l'estudi i anàlisi d'aquestos paràmetres, pel que s'han detallat les fórmules i el procediment de càlcul emprat per a la seua obtenció, que en alguns casos pot presentar una gran complexitat en el tractament de les dades experimentals. A partir de l'estudi de la evolució a curt termini de les variables representatives del funcionament de la instal·lació, s'identifiquen les principals característiques del comportament dinàmic del sistema, que s'intentaran reproduir amb el model desenvolupat. Per altra banda, l'estudi dels paràmetres característics del funcionament al llarg de diversos anys es realitza tenint en compte els valors corresponents a promitjos mensuals. En aquest anàlisi s'identifiquen també les tendències característiques del comportament del sistema a llarg termini, que posteriorment el model global de la instal·lació deurà ser capaç de reproduir. El model global s'ha desenvolupat utilitzant la ferramenta TRNSYS. Amb aquest fi s'ha seguit una estratègia d'incorporació progressiva de components. A cada pas s'assegura un correcte ajust del model mitjançant la validació amb dades experimentals, la qual cosa permet identificar i aïllar els efectes de cada component sobre els resultats finals. Al incloure l'intercanviador soterrat en el model global, queda de manifest la necessitat d'un nou model d'intercanviador soterrat capaç de reproduir el comportament tant dinàmic com estàtic de la temperatura de l'aigua a la eixida del tub. Així, com últim punt de la tesi, s'ha desenvolupat un model d'intercanviador soterrat, basat en la combinació de dos models distints: el model \emph{g-function} per a tindre en comte el comportament a llarg termini de la temperatura del terreny i el model B2G, desenvolupat específicament per a aquesta aplicació. Aquest model d'intercanviador soterrat ha sigut degudament validat amb dades experimental de dos intercanviadors distints i, posteriorment, s'ha inclòs en el model global de la instal·lació. El model global de la instal·lació desenvolupat d'aquesta manera aconsegueix reproduir amb precisió els resultats experimentals del funcionament del sistema tant a curt com a llarg termini, inclús després d'aplicar-hi les mateixes modificacions que s'han anat aplicant a la instal·lació experimental al llarg dels anys, y resulta ser, per tant, una ferramenta útil per al desenvolupament de futures estratègies d'optimització energèti
Ruiz Calvo, F. (2015). Análisis y modelado de una instalación geotérmica para climatización de un conjunto de oficinas [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/54134
TESIS
APA, Harvard, Vancouver, ISO, and other styles
17

Cabrera, Pasache Klisman César. "Comparación de tipos de enfriamiento evaporativo mediante modelos analíticos y experimentales." Bachelor's thesis, Pontificia Universidad Católica del Perú, 2020. http://hdl.handle.net/20.500.12404/17552.

Full text
Abstract:
El presente trabajo de investigación presenta un análisis del enfriamiento evaporativo, ya que se buscan alternativas distintas al sistema convencional por compresión de vapor por su alto consumo de energía y uso de refrigerantes de clorofluorocarbono, que afectan negativamente al medio ambiente; de manera contraria, el enfriamiento evaporativo usa el agua como refrigerante, además de poseer un menor consumo de energía, ya que usa normalmente una bomba centrífuga en vez de un compresor. El objetivo principal del documento es comparar los diferentes tipos de enfriamiento evaporativo para establecer el más apropiado para una aplicación de climatización. En primer lugar, se presentará una descripción de los conceptos y características de los tipos de enfriamiento, así como sus desventajas y desventajas, luego se realizará un análisis de transferencia de calor y masa para los tipos de enfriamiento evaporativo planteados y se plantearán modelos tanto analíticos como experimentales que permiten predecir características importantes como la temperatura y humedad que resultan del proceso. Finalmente, se evaluarán todos los modelos planteados para evaluar su comportamiento y luego se realizará una comparación en base a los resultados obtenidos. Se concluyó que el mejor tipo de enfriamiento evaporativo para una aplicación de climatización es el Dew Point Evaporative Cooling por su mayor capacidad para obtener una temperatura menor a su salida, a pesar de su mayor complejidad para su fabricación.
Trabajo de investigación
APA, Harvard, Vancouver, ISO, and other styles
18

Riquelme, Herrera María Francisca. "Conjunto Parque Pedro de Valdivia : conjunto habitacional integrado con sistema de climatización geotérmica en Temuco." Tesis, Universidad de Chile, 2017. http://repositorio.uchile.cl/handle/2250/168289.

Full text
APA, Harvard, Vancouver, ISO, and other styles
19

Meneses, Pérez Orlando Andrés. "Diseño de un intercambiador de calor aire-tierra para generar calefacción y climatización de edificios en Santiago." Tesis, Universidad de Chile, 2007. http://www.repositorio.uchile.cl/handle/2250/104758.

Full text
APA, Harvard, Vancouver, ISO, and other styles
20

Marianacci, Guillermo Arturo. "Diseño de un edificio educativo bajo el concepto de envolvente térmica eficiente." Bachelor's thesis, Facultad de Ciencias Exactas, Físicas y Naturales Universidad Nacional de Córdoba, 2017. http://hdl.handle.net/11086/6253.

Full text
Abstract:
Práctica Supervisada (IC)--FCEFN-UNC, 2018
Propone refuncionalizar una estructura de hormigón armado preexistente en el predio de la facultad para que la misma puede alojar nuevas aulas y laboratorios. La propuesta desarrollada y elegida consta de 3 laboratorios en planta baja, 5 aulas en el primer piso y 4 aulas en el segundo piso. El edificio contará con baños en cada nivel equipados para personas con movilidad reducida y se instalarán escaleras de emergencias en el lado exterior Este, del edificio
APA, Harvard, Vancouver, ISO, and other styles
21

Clemente, Jerez Ana María Paulina, and Quezada Alexis Osvaldo Arellano. "Clean Air Systems." Tesis, Universidad de Chile, 2018. http://repositorio.uchile.cl/handle/2250/164093.

Full text
Abstract:
TESIS PARA OPTAR AL GRADO DE MAGÍSTER EN ADMINISTRACIÓN
Clemente Jerez, Ana María Paulina, [Parte I], Arellano Quezada, Alexis Osvaldo, [Parte II]
El gasto energético de un Edificio en Chile fluctúa entre el 40% y el 65% del gasto total. “Clean Air Systems”, gracias a su producto Steril-aire permite reducir costos energéticos entre un 10% a 30% del consumo de climatización; además de la reducción en consumo de agua, costos de mantenimiento, mejoras de eficiencia operativa, y otros beneficios a través de eficiencias complementarias. El servicio está dirigido a distintos equipos de distintos clientes, determinado por los requerimientos específicos de cada uno de ellos. El mercado lo constituyen las edificaciones con equipamiento de climatización. El Mercado Actual de Oficinas en el año 2017 posee un tamaño de 3.898.865 metros cuadrados, con un crecimiento promedio para edificaciones de tipo sustentable y no sustentable del 7% anual (mercado potencial). El Mercado Potencial se estima en el 69% compuesto por Edificios clase A, B y C. El EBITDA varía entre el 13,63% y el 23,95% al año 5. Las Utilidades siempre positivas se mantiene relativamente constantes, fluctuando entre los $53.538.397, y $140.624.457 en el quinto año. El Flujo de Caja nos indica que el monto de la inversión inicial es de $150.000.000; y los flujos de $91.215.208 año 1, $117.043.243 año 2, $123.374.736 año 3, $152.867.622 año 4, y de $196.938.154 año 5. Obteniendo un VAN (25%) de $150.555.983.-; y una TIR de 70,70%. El plan de negocios en la comercialización del servicio para el cliente trae muchos beneficios, Steril-Aire es una tecnología limpia, libre de químicos, sustentable, y que sólo utiliza el oxígeno; abarcando problemas como la calidad del aire, costos energéticos, y sanitarios. Las Estrategias a utilizar son básicamente dos: Estrategia para Proyectos No Sustentables y para Proyectos Sustentables. En la última diferenciamos Estrategia de Eficiencia Energética. Estas estrategias no son excluyentes, sino que tienen un énfasis distinto en cada segmento. El Green Marketing se utilizará agregando valor de la mano de la conciencia empresarial. La publicidad dirigida a empresas que busquen transformarse en empresas verdes o acercarse a una mayor sustentabilidad, serán actividades a implementar aprovechando este segmento de clientes preocupados del medio ambiente. Finalmente se muestra una planificación de crecimiento estimada para los próximos 5 años y la propuesta para futuros inversionistas.
APA, Harvard, Vancouver, ISO, and other styles
22

Medina, Medina Julio Santiago. "Diseño de un sistema de climatización para una piscina temperada ubicada en la ciudad de Lima." Bachelor's thesis, Universidad Nacional Mayor de San Marcos, 2014. https://hdl.handle.net/20.500.12672/9267.

Full text
Abstract:
Publicación a texto completo no autorizada por el autor
Plantea el diseño de un sistema de climatización para una piscina temperada, ubicada en la ciudad de Lima, debido a que actualmente los diferentes centros recreacionales, clubes, hoteles, spas y otros centros cuentan con piscinas climatizadas en sus ambientes se ha visto la necesidad de establecer las condiciones mínimas de calidad, dimensionamientos, capacidades y criterios básicos para las instalaciones de dichos ambientes. Previamente al desarrollo del proyecto se establecen definiciones relacionadas con los sistemas de aire acondicionado, componentes y accesorios. A su vez se mencionan normas y recomendaciones importantes a seguir para el diseño. Se han realizado los cálculos de tasa de evaporación y se ha seleccionado un equipo especial tipo split y así como el diseño de la red de ductos de distribución del aire acondicionado de este proyecto.
Trabajo de suficiencia profesional
APA, Harvard, Vancouver, ISO, and other styles
23

Martínez, Ayala René Alejandro. "Evaluación técnica del sistema de climatización para las oficinas de la tribuna sur del estadio nacional." Bachelor's thesis, Universidad Nacional Mayor de San Marcos, 2016. https://hdl.handle.net/20.500.12672/5773.

Full text
Abstract:
Publicación a texto completo no autorizada por el autor
El documento digital no refiere asesor
Desarrolla paso a paso los cálculos, el diseño y la elaboración del presupuesto del sistema más apropiado que permita satisfacer los requerimientos de confort planteados para cada ambiente de las oficinas de la tribuna sur del estadio nacional.
Trabajo de suficiencia profesional
APA, Harvard, Vancouver, ISO, and other styles
24

Vásconez, Núñez Daniela Carina. "Desarrollo de un modelo para el cálculo del consumo de climatización en vehículos de pasajeros urbanos." Doctoral thesis, Universitat Politècnica de València, 2019. http://hdl.handle.net/10251/121133.

Full text
Abstract:
[ES] El sistema de climatización es uno de los equipos auxiliares más importantes de un vehículo, el cual mantiene un ambiente térmicamente confortable al controlar la temperatura y la humedad relativa del aire interior, sin embargo, su utilización incrementa el consumo energético global del vehículo. En la presente tesis doctoral, se desarrolla un modelo global para calcular el consumo energético y las emisiones de CO2 del sistema de climatización de vehículos cuando estos recorren un trayecto determinado. El modelo global está comprendido de tres submodelos. El primer submodelo es un modelo térmico dinámico de la cabina de un vehículo que estima la variación de la temperatura y humedad del aire interior en función de las diferentes cargas térmicas y de las condiciones exteriores (temperatura ambiente y radiación solar). El modelo fue validado de acuerdo con dos ensayos experimentales, con y sin radiación solar. Además, el modelo calcula la demanda térmica que necesita satisfacer el sistema de climatización para mantener el interior del vehículo a una temperatura predefinida. El segundo submodelo consiste en un modelo del equipo de aire acondicionado, que contiene modelos detallados de los diferentes componentes del ciclo de compresión de vapor (compresor, evaporador, condensador, dispositivo de expansión, etc.). Este modelo genera mapas de prestaciones del equipo de aire acondicionado para diferentes condiciones de trabajo (temperaturas de entrada al evaporador y condensador, velocidad del compresor, humedad relativa, etc.). El tercer submodelo integra el modelo térmico dinámico del vehículo con el modelo del equipo de aire acondicionado. Este modelo determina las prestaciones del equipo de aire acondicionado en cada paso de tiempo, en función de la demanda de refrigeración instantánea; además, calcula el consumo y las emisiones de CO2 producidas por el sistema de climatización cuando el vehículo realiza una trayectoria definida, tomando en cuenta el tipo de accionamiento del compresor (mecánico o eléctrico) y sus respectivas eficiencias de la cadena de transformación de energía. El modelo desarrollado considera la variación de las condiciones climatológicas y los cambios de dirección que el vehículo realiza a lo largo del trayecto. Finalmente, se presenta un caso de estudio en donde se estima el consumo energético y las emisiones de CO2 del sistema de climatización de un autobús con accionamiento mecánico y eléctrico. Se consideró un autobús de 50 pasajeros que realiza un trayecto extraurbano (ida y vuelta) entre las ciudades de Valencia y Madrid en un día típico de verano. Los resultados muestran que el sistema de climatización con accionamiento mecánico consume 10.2 litros de combustible (gasoil) y emite 27.3 kg de CO2 durante el viaje de ida, asumiendo que el equipo funciona a una velocidad constante del compresor de 2000 rpm. Por otro lado, el sistema de climatización en el autobús impulsado eléctricamente consume 18.1 kWh durante el viaje de ida y genera 8,2 kg de emisiones indirectas de CO2
[CAT] El sistema de climatització és un dels equips auxiliars més importants d'un vehicle, el qual manté un ambient tèrmicament confortable al controlar la temperatura i la humitat de l'aire interior, no obstant això, la seua utilització incrementa el consum energètic global del vehicle. En la present tesi doctoral, es desenvolupa un model global per a calcular el consum energètic i les emissions de CO2 del sistema de climatització de vehicles quan aquests recorren un trajecte determinat. El model global està comprés de tres submodels. El primer submodel és un model tèrmic dinàmic de la cabina d'un vehicle que estima la variació de la temperatura i humitat de l'aire interior en funció de les diferents càrregues tèrmiques i de les condicions exteriors (temperatura ambient i radiació solar). El model va ser validat d'acord amb dos assajos experimentals, amb i sense radiació solar. A més, el model calcula la demanda tèrmica que necessita satisfer el sistema de climatització per a mantenir l'interior del vehicle a una temperatura predefinida. El segon submodel consisteix en un model de l'equip d'aire condicionat, que conté models detallats dels diferents components del cicle de compressió de vapor (compressor, evaporador, condensador, dispositiu d'expansió, etc.). Aquest model genera mapes de prestacions de l'equip d'aire condicionat per a diferents condicions de treball (temperatures d'entrada a l'evaporador i condensador, velocitat del compressor, humitat relativa, etc.). El tercer submodel integra el model tèrmic dinàmic del vehicle amb el model de l'equip d'aire condicionat. Aquest model determina les prestacions de l'equip d'aire condicionat en cada pas de temps, en funció de la demanda de refrigeració instantània; a més, calcula el consum i les emissions de CO2 produïdes pel sistema de climatització quan el vehicle realitza una trajectòria definida, tenint en compte el tipus d'accionament del compressor (mecànic o elèctric) i les seues respectives eficiències de la cadena de transformació d'energia. El model desenvolupat considera la variació de les condicions climatològiques i els canvis de direcció que el vehicle realitza al llarg del trajecte. Finalment, es presenta un cas d'estudi on s'estima el consum energètic i les emissions de CO2 del sistema de climatització d'un autobús amb accionament mecànic o elèctric. Es va considerar un autobús de 50 passatgers que realitza un trajecte extraurbà (anada i tornada) entre les ciutats de València i Madrid en un dia típic d'estiu. Els resultats mostren que el sistema de climatització amb accionament mecànic consumeix 10.2 litres de combustible (gasoil) i emet 27.3 kg de CO2 durant el viatge d'anada, assumint que l'equip funciona a una velocitat constant del compressor de 2000 rpm. D'altra banda, el sistema d'aire condicionat en l'autobús impulsat elèctricament consumeix 18.1 kWh durant el viatge d'anada i genera 8,2 kg d'emissions indirectes de CO2.
[EN] The air conditioning system is one of the most important auxiliary systems in a vehicle. It provides a thermally comfortable environment by controlling the temperature and relative humidity of the indoor air; however, its excessive use increases the overall energy consumption of the vehicle. In the present Ph.D. thesis, a global model is developed to calculate the energy consumption and CO2 emissions of the automotive air conditioning system, when the vehicle travels in a determined path. The main model comprises three sub-models. The first sub-model corresponds to a dynamic thermal model of the vehicle's cabin that estimates the temperature and humidity variation of the vehicle's interior air according to the different thermal loads and the external conditions (temperature and solar radiation). It was validated according to two experimental tests, with and without solar radiation. In addition, the model calculates the thermal demand that the air conditioning system needs to maintain the interior of the vehicle at a predefined temperature. The second submodel consists in a model of air conditioning equipment, which contains detailed models of the different components of the steam compression cycle (compressor, evaporator, condenser, expansion device, etc.).This model generates performance maps for different working conditions (evaporator and condenser inlet temperatures, compressor speed, etc.). The third submodel integrates the dynamic thermal model of the vehicle with the model of the air conditioning equipment. It determines the performance of the air conditioning system for each time step based on the cooling load. Furthermore, it calculates the consumption and emissions produced by the air conditioning system when the vehicle performs a defined path. In this study, mechanically or electrically driven compressors with their respective efficiencies of the energy transformation chain were considered. The developed model takes into account the weather conditions and changes of direction that the vehicle takes along the journey Finally, a case study is presented to analyze the energy consumption and CO2 emissions of air conditioning system for a bus driven by a mechanical or an electrical motor. A 50-passenger bus was considered in the analysis. The bus makes a round trip from Valencia to Madrid on a typical summer day. Results show that the mechanically driven bus consumes 10.2 liters of fuel (diesel) and exhausts 27.3 kg of CO2 during the outward journey. The air conditioning system, in this case, is assumed to be operating at a constant compressor speed of 2000 rpm. On the other hand, the air conditioning system in electrically driven bus consumes 18.1 kWh during the outward trip and produces 8.2 kg of indirect CO2 emissions.
Además, quiero reconocer el soporte financiero brindado por el programa de becas para estudios de posgrado “CONVOCATORIA ABIERTA 2013-SEGUNDA FASE”, que fue financiado por la SENESCYT (Secretaría de Educación Superior, Ciencia, Tecnología e Innovación) (Adjudicación No 2014-AR3R7463) de Ecuador.
Vásconez Núñez, DC. (2019). Desarrollo de un modelo para el cálculo del consumo de climatización en vehículos de pasajeros urbanos [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/121133
TESIS
APA, Harvard, Vancouver, ISO, and other styles
25

Martínez, Ayala René Alejandro, and Ayala René Alejandro Martínez. "Evaluación técnica del sistema de climatización para las oficinas de la tribuna sur del estadio nacional." Bachelor's thesis, Universidad Nacional Mayor de San Marcos, 2016. http://cybertesis.unmsm.edu.pe/handle/cybertesis/5773.

Full text
Abstract:
Publicación a texto completo no autorizada por el autor
El documento digital no refiere asesor
Desarrolla paso a paso los cálculos, el diseño y la elaboración del presupuesto del sistema más apropiado que permita satisfacer los requerimientos de confort planteados para cada ambiente de las oficinas de la tribuna sur del estadio nacional.
Trabajo de suficiencia profesional
APA, Harvard, Vancouver, ISO, and other styles
26

Jara, Jopia Camilo Sebastián. "Factibilidad técnico-económica de climatización en el Norte Grande mediante ciclo de absorción y energía solar térmica." Tesis, Universidad de Chile, 2015. http://repositorio.uchile.cl/handle/2250/137570.

Full text
Abstract:
Ingeniero Civil Mecánico
Un ciclo de refrigeración por absorción aprovecha la capacidad que presentan ciertas sustancias, de absorber a otra en fase de vapor, así el refrigerante evaporado es absorbido por otra sustancia que permanece en estado líquido, con lo cual para pasar a la etapa de alta presión se requiere bombear la mezcla y no comprimir el refrigerante en forma de vapor, lo cual conlleva un considerable ahorro de energía. Para desabsorber el refrigerante se requiere de un flujo de calor, el cual en este caso está dado por energía solar térmica. Para determinar la factibilidad técnica y económica, se considera un caso de estudio, el cual consiste en un galpón ubicado en la comuna de Antofagasta. A dicha construcción se le determina la carga de enfriamiento, sujeta a diferentes condiciones de uso, además de estudiar cómo influye la geometría y la orientación espacial del galpón en su carga de enfriamiento. El caso de estudio presenta una carga de enfriamiento de diseño de 25,6 [KW]. En cuanto a los ciclos termodinámicos por absorción, se estudian las parejas de fluido de agua-bromuro de litio y amoniaco-agua, en ciclos termodinámicos por absorción que satisfacen los requerimientos de la carga de enfriamiento del galpón. Se determina cómo influyen las diferentes combinaciones de fracciones másicas en ambas parejas de fluidos. Una vez determinados los ciclos termodinámicos, se tiene que para las temperaturas y cargas de enfriamientos del galpón, la pareja de fluidos que mejor se adapta a la situación corresponde a bromuro de litio-agua. De esta manera, se busca un chiller que sirve para dichas pareja de sustancia, encontrándose en el mercado dicho equipo. Los demás equipos requeridos para el sistema de climatización del caso de estudio, se encuentran en el mercado, con lo cual el proyecto es factible desde el punto de vista técnico. En cuanto a la evaluación económica, se determina que el ahorro de energía eléctrica que trae como beneficio la implementación de un sistema basado en absorción, no compensa la inversión inicial de los equipos adicionales que se requieren, así tampoco compensan los gastos asociados a la mantención y operación del sistema que provee energía solar térmica. Así, el caso de estudio no es factible desde el punto de visto económico, puesto que se obtiene un VPN de -$ 55.522.718.
APA, Harvard, Vancouver, ISO, and other styles
27

Lamas, Sivila Edwin Víctor. "ANÁLISIS Y PROPUESTA DE UN NUEVO MÉTODO DE SIMULACIÓN ABREVIADO PARA LA CERTIFICACIÓN ENERGÉTICA EN EDIFICIOS RESIDENCIALES." Doctoral thesis, Universitat Politècnica de València, 2011. http://hdl.handle.net/10251/10986.

Full text
Abstract:
Los compromisos asumidos por España, junto con la Unión Europea, con la entrada en vigor del protocolo de Kioto y el compromiso de Montreal son la reducción de las emisiones de CO2 fósil emitidas al ambiente. Una de las principales fuentes de emisión de CO2 tiene su origen en la necesidad de climatizar los edificios (calefacción, refrigeración y ACS). Con esta finalidad España establece el Real Decreto RD 47/ 2007 de certificación energética en edificios de nueva construcción, cuya finalidad es informar sobre las emisiones de CO2 fósil emitidos por los edificios. Para determinar la etiqueta energética, se ponen a disposición de los técnicos, métodos generales de certificación, implementados en los programas CALENER VYP y CALENER GT. Estos programas realizan una simulación del edificio, determinando las demandas y consumos de energía de los mismos. A partir de coeficientes de paso (conversión de energía a emisiones de CO2) se calcula la calificación energética del edificio. En este trabajo se propone un método alternativo al programa oficial (CALENER VYP) de certificación energética dirigida a edificios del tipo residencial. Este método es abreviado, pero realiza una simulación del edificio similar a los métodos generales. Como ventajas presenta un cálculo rápido, la fácil entrada de datos y los resultados permiten evaluar el impacto de distintas alternativas en las características del edificio, ayudando a profesionales a mejorar el diseño de los mismos. El método propuesto en la simulación utiliza factores de respuesta para determinar los fenómenos de transferencia por conducción. Para contabilizar el intercambio energético entre los cerramientos interiores de la zona, el método aplica como una aproximación el método de las series temporales radiantes "Radiant Time Series". La validez de la aproximación ha sido evaluada comparando con el programa EnergyPlus. Programa que utiliza para el cálculo el método del balance.
Lamas Sivila, EV. (2011). ANÁLISIS Y PROPUESTA DE UN NUEVO MÉTODO DE SIMULACIÓN ABREVIADO PARA LA CERTIFICACIÓN ENERGÉTICA EN EDIFICIOS RESIDENCIALES [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/10986
Palancia
APA, Harvard, Vancouver, ISO, and other styles
28

González, Espín José Luis. "Caracterización térmica y optimización de las estrategias de operación de vigas frías activas en sistemas de climatización de edificios." Doctoral thesis, Universitat Rovira i Virgili, 2019. http://hdl.handle.net/10803/668968.

Full text
Abstract:
L'aparició de condensació en la bateria d’intercanvi de calor és un dels principals problemes a evitar en una biga freda activa. En climes humits, per les infiltracions d'aire exterior, i en espais d'elevat guany latent, la càrrega latent d’un local pot ser elevada, i les bigues fredes actives poden presentar problemes de condensació. La present tesi doctoral conté totes les fases necessàries per al desenvolupament i validació d'un nou model numèric de biga freda activa, i la seva posterior adaptació com a nou component d'una eina de càlcul per a la simulació tèrmica de la biga freda activa acoblada al sistema de climatització de l'edifici. Mitjançant simulacions tèrmiques dinàmiques anuals, la present tesis doctoral mostra que el sistema de prevenció de condensació normalment utilitzat pot ser motiu d’un elevat número d’hores de desconfort tèrmic. Per a això, s’implementen models matemàtics pseudo-estacionaris del sistema complet (biga freda activa, climatitzadora i producció tèrmica), adequades per estimar el consum horari per un any tipus complert. Amb aquests models es comparen dissenys alternatius del sistema de control de condensació. Finalment, es compara el consum elèctric de les instal·lacions de bigues fredes actives dins del mercat dels sistemes aire-aigua, i en particular en relació amb els ventiloconvectors. Existeixen alguns estudis al respecte realitzats per fabricants de cadascun dels sistemes, però no tenen objectivitat. En la present tesi doctoral es comparen aquets dos sistemes en diferents aplicacions i climes d'Espanya, a fi de determinar les prestacions de cada tecnologia i identificar nínxols de mercat en què el sistema de biga freda activa pot seguir expandint-se.
La aparición de condensación en la batería de intercambio de calor es uno de los principales problemas a evitar en una viga fría activa. En climas húmedos, por las infiltraciones de aire exterior, y en espacios de elevada ganancia latente, la carga latente del local es elevada, y las vigas frías activas pueden presentar el problema de la condensación. La presente tesis doctoral contiene todas las fases necesarias para el desarrollo y validación de un nuevo modelo numérico de viga fría activa, y su posterior adaptación como nuevo componente de un motor de cálculo para la simulación térmica de la viga fría activa acoplada al edificio, y al resto de componentes del sistema. Mediante simulaciones térmicas anuales, la presente tesis doctoral demuestra que el sistema de prevención de condensación comúnmente utilizado, puede dar lugar a un elevado número de horas de disconfort térmico. Para ello, se implementan modelos matemáticos pseudo-estacionarios del sistema completo (viga fría activa, climatizadora y producción térmica), adecuados para estimar el consumo horario para un año tipo completo. Con estos modelos se comparan diseños alternativos del sistema de control de condensación. Finalmente, se compara el consumo eléctrico de las instalaciones de vigas frías activas dentro del mercado de los sistemas aire-agua, y en particular en relación con los ventiloconvectores. Existen algunos estudios al respecto realizados por fabricantes de cada uno de los sistemas, pero carecen de objetividad. En la presente tesis doctoral se comparan ambos sistemas en diferentes aplicaciones y climas de España, a fin de determinar las prestaciones de cada tecnología e identificar nichos de mercado en los que el sistema de viga fría activa puede seguir expandiéndose.
The appearance of condensation in the coil is one of the main problems to avoid in an active chilled beam of building air-conditioning systems. In humid climates, by infiltrations of outside air, and in spaces with high latent load, the latent load of the stay is high, and active chilled beams can present the problem of condensation. This doctoral thesis contains all the necessary stages for the development and validation of a new numerical model of active chilled beams, and its adaptation as a new component of a calculation tool for the thermal simulation of the active chilled beam coupled to the building, and the rest of the system components. Through annual dynamic thermal simulations, this doctoral thesis shows that the commonly used condensation prevention system, can lead to a high number of hours of thermal discomfort. For this, pseudo-stationary mathematical models of the complete system (active chilled beam, air conditioners and thermal production units), which are suitable for estimating the hourly consumption for a complete type year, are implemented. In addition, these models are used in order to compare alternative designs of the condensation control system. Finally, the electrical consumption of active chilled beams installations in the air-water systems market is compared, and in particular in relation to fan-coils. There are some studies in this regard by manufacturers of each of the systems, but they lack objectivity. In this doctoral thesis both systems are compared in different applications and climates in Spain, in order to determine the performance of each technology and identify market niches in which the active chilled beam system can continue to expand.
APA, Harvard, Vancouver, ISO, and other styles
29

Sánchez, Muggi Ronald, and Cornejo Luis Alberto Pelaez. "Red de Control y Monitoreo Remoto de Iluminación, Climatización, Transferencia automática y Energía en Agencias Bancarias del Banco Continental." Bachelor's thesis, Universidad Ricardo Palma. Programa Cybertesis PERÚ, 2007. http://cybertesis.urp.edu.pe/urp/2007/sanchez_lr/html/index-frames.html.

Full text
APA, Harvard, Vancouver, ISO, and other styles
30

Auris, Casma Omar Tadeo. "Diseño de un sistema de climatización para un domo de 50m2 de uso familiar en la ciudad de Pisco." Bachelor's thesis, Pontificia Universidad Católica del Perú, 2017. http://tesis.pucp.edu.pe/repositorio/handle/123456789/9560.

Full text
Abstract:
En la presente tesis se diseña un sistema de climatización que proporcione condiciones de confort en época de verano e invierno para un domo geodésico de uso familiar. Este domo será diseñado solo para ser instalado en la ciudad de Pisco, ya que para la determinación de la radiación incidente se consideró la latitud y longitud del lugar mencionado. Por un lado, para la carga térmica de refrigeración, se considera al domo como un conjunto de placas de 1 m x 0.85 m dispuestas en 8 niveles para así estimar la irradiación total incidente sobre cada placa y consecuentemente sobre el domo. Además, teniendo en cuenta la misma suposición, se calcula los coeficientes globales de transferencia de calor para cada nivel ya que este es un factor importante en el cálculo de la carga térmica por transmisión de calor. Por otro lado, para la carga térmica de calefacción, el domo fue considerado como una esfera completa para la simplificación de los cálculos; sin embargo, se utilizaron factores de corrección debido a que el domo es semiesférico. A continuación, se procede a determinar la carga térmica de refrigeración y calefacción las cuales son 4370 W (14902 BTU/h) y 1011 W (3450 BTU/h) respectivamente. Asimismo, se estima un mínimo de 140 m³/h (81 CFM) de aire exterior para cumplir con los requerimientos de ventilación. Se utiliza la metodología propuesta por el Handbook Fundamentals de ASHRAE. De acuerdo a los valores obtenidos, se selecciona un extractor de pared para la renovación de aire y un conjunto de equipos de climatización compuesto por un split ducto y un calentador eléctrico para proporcionar confort térmico al ambiente. Finalmente, se realiza una evaluación económica referente al costo del sistema seleccionado, donde se incluyen diversos costos tales como: costo inicial, costo de instalación, costo de operación y costos de mantenimiento.
Tesis
APA, Harvard, Vancouver, ISO, and other styles
31

Paniagua, José Roberto Zúñiga. "Práctica profesional y su proyección a la aplicación eficiente de sistemas solar térmicos y de climatización en Costa Rica." Master's thesis, Instituto Politécnico de Bragança, Escola Superior de Tecnologia e Gestão, 2012. http://hdl.handle.net/10198/8237.

Full text
Abstract:
En este proyecto se presenta una recopilación de lo aprendido durante la práctica profesional en la empresa Mecatérmica, Sociedade Mecânica Térmica, Lda, ubicada en Bragança, Portugal, durante el período del 24 de enero al 31 de mayo del año 2012. Se presenta inicialmente una breve descripción de cada uno de los proyectos en los que se participó, considerando la localización, las condiciones climáticas del entorno y las medidas que fueron presentadas para presentar una solución. Posteriormente se hace una mayor profundización en cada uno de los sistemas y las diferentes técnicas y dimensionamientos que fueron realizados, esto mediante un proyecto tipo de climatización y calentamiento de agua. Para poder explicar detalladamente, se utilizaron ejemplos tomados de los proyectos en los cuales se trabajó durante la práctica profesional. Además contiene una breve descripción de las labores realizadas en las obras como complemento de lo realizado en diseño de o cina. Finalmente se realiza un análisis de la aplicación e ciente de sistemas de climatización y aprovechamiento solar en Costa Rica. Mediante un análisis de las técnicas más adecuadas para climatización por medio del estudio de la carta de Givoni y otras medidas presentes en la arquitectura bioclimática. Para el caso del aprovechamiento solar, se realizó una comparación entre un sistema ubicado en Bragança, Portugal y otro en San José, Costa Rica. Utilizando como parámetro una núcleo familiar de 5 miembros. Mediante esta comparación se logró observar la e ciencia de este tipo de sistemas para la zona de San José y las diferencias que se presentan entre ambos sistemas debido a la localización. This project is a compilation of what was learned during the professional practice at Mecatérmica, Sociedade Mecânica Thermal, Lda, located in Bragança, Portugal, during January 24th to May 31st of 2012. It initially presents a brief description of each of the projects involved, considering the location, climatic conditions of the environment and the measures that were introduced to present a solution. Later it becomes more insight into each of the systems and techniques and design that were made, through a model project of air conditioning and water heating. To explain in detail, were used examples from projects in the professional practice. It also contains a brief description of the work done in site to complement the design that was done in o ce. Finally, an analysis of the e cient application of air conditioning and solar systems in Costa Rica. By analyzing the most appropriate techniques for achieving thermal confort through studying the letter of Givoni and other measures present in environmental design. In the case of solar energy, it was made a comparison between a system located in Bragan ça, Portugal and one in San Jose, Costa Rica. Using as a parameter a family of 5 members. Through this comparison it was possible to observe the e ciency of such systems for San Jose and the di erences between both systems due to the location.
APA, Harvard, Vancouver, ISO, and other styles
32

Ortega, Leiva Bruno Adrián. "Evaluación de un sistema de climatización con bomba de calor geotérmica para una casa representativa en diferentes climas de Chile." Tesis, Universidad de Chile, 2017. http://repositorio.uchile.cl/handle/2250/147047.

Full text
Abstract:
Ingeniero Civil Mecánico
La energía geotérmica, ya sea de alta, mediana o baja entalpía, tiene un desarrollo insuficiente en Chile, debido en parte al alto costo de implementación, en conjunto de escasos estudios locales y específicos para el desarrollo de esta. Es por esto que se hace necesario aportar con estudios técnicos y económicos para distintos casos en Chile. El estudio se centra en realizar un análisis técnico-económico para el uso de energía geotérmica de baja entalpía, mediante la utilización de un sistema de climatización residencial evaluando 9 diferentes regiones del país en una vivienda de 77 [m2]. El sistema de climatización se basa en bomba de calor geotérmica (BCG), utilizando intercambiadores de calor geotérmicos (ICG) de tubos enterrados horizontalmente a 1,5 [m] de profundidad en ciclo cerrado y ventiloconvector (fancoil) como sistema de distribución. La metodología que se aborda en este trabajo comprende una primera parte de recolección de antecedentes para la cuantificación de cargas térmicas de la vivienda, para posteriormente dimensionar la bomba de calor geotérmica. Los antecedentes recolectados se integran a un modelo computacional (de MatLab) para la rápida adquisición de resultados por ciudad evaluada, las cuales corresponden a Arica, Calama, Vallenar, Coquimbo, Santiago, Temuco, Valdivia, Coyhaique y Punta Arenas. Con la evaluación técnica definida, se realiza una evaluación económica mediante el costo nivelado de energía (CNdE), para luego desarrollar una comparación entre las distintas ciudades haciendo una valoración de distintas variables como la capacidad térmica de la BCG, la demanda energética de la vivienda, el coeficiente de operatividad (COP), un indicador de transferencia de calor por metro lineal de tubería (que indica la calidad del recurso geotermal de baja entalpía) y el CNdE. El modelo computacional se valida comparando resultados como la carga térmica del hogar, el ciclo termodinámico resultante, el COP y su eficiencia respecto al COP máximo teórico y el indicador de transferencia de calor por metro lineal de tubería, todo respecto a la bibliografía utilizada. La ciudad con menor y mayor potencia térmica de BCG corresponde a Coquimbo y Santiago con 3,11 y 5,31 [kW] respectivamente. Así mismo, la localidad con menor y mayor demanda energética concierne a Coquimbo y Punta Arenas con 7.641 y 19.824 [kWht/año] respectivamente. Por otra parte, la ubicación con mayor y menor COP pertenece a Arica y Coyhaique, con 4,53 y 3,33 (donde el COP mínimo factible para la implementación de BCG es de 2,97). Luego, la zona con mayor índice de transferencia de calor por metro lineal compete a Punta Arenas y Coyhaique con 13,96 [W/m] y Valdivia con el menor índice, de 10,34 [W/m]. Por último, el menor y mayor CNdE corresponde a Punta Arenas y Arica con 54 y 77 [$/kWht] respectivamente. La ciudad recomendada para la implementación de BCG, respecto a la valoración de variables realizada corresponde a Punta Arenas, seguido por Coyhaique y Vallenar.
APA, Harvard, Vancouver, ISO, and other styles
33

Galindo, Mauricio Fernando Alberto. "Diseño de un sistema de mantenimiento a una planta enfriadora (Chiller) refrigerada por aire, aplicada en la industria de la climatización." Bachelor's thesis, Universidad Nacional Mayor de San Marcos, 2018. https://hdl.handle.net/20.500.12672/9666.

Full text
Abstract:
Muestra el diseño de un sistema de mantenimiento a una planta enfriadora de agua helada (CHILLER) aplicada en la industria de la climatización; ya que se carecía de una correcta literatura así como una aplicación adecuada de este proceso de mantenimiento en el sector HVAC para este tipo de equipos. Para dar solución a este inconveniente, se diseñó una estrategia que sea capaz de que se aplique el proceso de mantenimiento en todas sus etapas de manera correcta y eficientemente por lo cual se lograra que el CHILLER funcione en su estado más óptimo. Se puede encontrar un análisis de los componentes existentes en el Chiller, además de los conceptos fundamentales; las cuales aportaron conocimientos a la consecución de este trabajo como opción de grado; se presenta además un estudio de mantenimiento actual y se propone el nuevo diseño de mantenimiento con el fin de reducir paros por fallas y lograr también reducir el impacto ambiental producidos por estos tipos de equipos y que como ya es sabido en estos últimos años los CFC han sido los causantes del daño a la capa de ozono, así como partes de piezas mecánicas que se hacen mucho más difíciles de reciclar. Este documento permite particularizar las mejoras que se pueden llegar a concebir con una combinación entre ingeniería y rediseño, permitiendo encontrar eficiencia en procesos; que para este caso el acondicionamiento de aire, presenta falencias; ya que son difíciles de controlar.
Tesis
APA, Harvard, Vancouver, ISO, and other styles
34

Sedano, Tapia Luis Gilbert. "Construcción de dos centros de reuniones. Pilotes, impermeabilización, climatización, arcos duplos de concreto y manual de términos técnicos en portugués. Brasil." Bachelor's thesis, Universidad Ricardo Palma, 2016. http://cybertesis.urp.edu.pe/handle/urp/1391.

Full text
Abstract:
Para el informe técnico por experiencia profesional calificado he escogido dos proyectos ejecutados en el Brasil, de esta forma presento una detallada descripción para la obtención de mejores costos en una licitación con la finalidad de disminuir el precio final de la construcción. Para los procesos constructivos expongo los casos de cimentaciones profunda con pilotes con su tipo de ensayo adecuado, la importancia de impermeabilizar elementos estructurales en contacto o enterrados en el suelo, la construcción de un duplo arco por túneles de concreto.
APA, Harvard, Vancouver, ISO, and other styles
35

Ribé, Óscar. "Estudio de la mejora de la eficiencia energética de la ventilación en sistemas de climatización con el uso de recuperadores de calor." Doctoral thesis, Universitat Politècnica de Catalunya, 2018. http://hdl.handle.net/10803/663906.

Full text
Abstract:
Energy recovery elements play a major role in the efficiency and sustainability of building ventilation systems. The use of a sensible or total energy recovery ventilator is a key decision for ventilation systems designers. However, there is a lack of technical tools and developments to support this decision. This study develop a simple decision tool for designers based on hourly values of the outdoor weather conditions and that can be applied to any kind of building. The main outcome of the study is a simple-to-use isoline maps and tables. In order to assess credibility of the model used in the procedure, results published in the literature have been used as a reference showing good accordance. As an example, the procedure has been applied to the Spanish area considering 48 different locations. Results have been presented and discussed. The analysis of the results conclude that the market-accepted recommendation of using energy recovery ventilators in locations with high relative humidity during the summer should be reconsidered.
Los recuperadores de calor juegan un papel importante en la eficiencia y la sostenibilidad en el diseño de los sistemas de ventilación. El uso de un recuperador de calor sensible o entálpico es una decisión clave para los diseñadores de sistemas de ventilación. Sin embargo, hay una falta de herramientas, de fácil uso e interpretación, que sirvan para poder tomar esta decisión. Este estudio desarrolla una herramienta de decisión simple para los ingenieros basada en los valores hora a hora de las condiciones climáticas exteriores y que se puede aplicar a cualquier tipo de edificio. El resultado principal del estudio son una serie de mapas y tablas simples de interpretar. Con el fin de evaluar la credibilidad del modelo utilizado en el procedimiento, se han comparado los resultados obtenidos con otros resultados publicados. El estudio se centra en 48 localidades de ámbito español. El análisis de los resultados concluye que la recomendación aceptada en el mercado de usar recuperadores de calor de tipo entálpico en lugares con alta humedad relativa durante el verano debe ser reconsiderada.
APA, Harvard, Vancouver, ISO, and other styles
36

Seisdedos, Saez Marco Antonio. "Climatización de edificios por medio del intercambio de calor con el subsuelo y agua subterránea, aspectos a considerar en el contexto local." Tesis, Universidad de Chile, 2012. http://www.repositorio.uchile.cl/handle/2250/111538.

Full text
Abstract:
Geólogo
En este trabajo se desarrollan los fundamentos de la geotermia de muy baja entalpía y su uso en la climatización de edificios, se revisan los aspectos conceptuales que motivan el desarrollo de esta tecnología, se explica el funcionamiento de la bomba de calor, se analizan los factores que determinan la demanda de una edificación, y se entregan herramientas para la cuantificación de la misma, explicando los tipos de diseño posibles en sistemas abiertos y cerrados y los equipos que es necesario utilizar. Se analiza en profundidad la teoría y equipamiento asociado al intercambio de calor con acuíferos, esto por la disponibilidad de este recurso en la ciudad de Santiago, la escalabilidad de los proyectos, la mayor dependencia de las variables geológicas y la rentabilidad asociada. Se analiza la importancia de las variables hidrogeológicas, los métodos por medio de los cuales se pueden cuantificar, la probabilidad de generar quiebres hidráulicos y térmicos durante la operación del sistema y las precauciones que se debe tener en consideración para una implementación exitosa. Por ultimo se analizan los aspectos regulatorios en Chile, y se ofrece un ejemplo teórico para implementar esta tecnología en un condominio ubicado en Las Condes, se analizan aspectos técnicos y económicos que conciernen al proyecto. La evaluación de este tipo de sistemas requiere una perspectiva multidisciplinaria, conociendo e interpretando adecuadamente los datos hidrogeológicos, estimando adecuadamente los patrones de consumo y la magnitud y ocurrencia de las máximas demandas. Desde el punto de vista técnico y económico esta tecnología muestra un gran potencial de desarrollo a nivel nacional, no obstante esto se requiere un involucramiento más activo de la autoridad en las políticas públicas, simplificando la regulación y estableciendo incentivos de apoyo concretos.
APA, Harvard, Vancouver, ISO, and other styles
37

Luna, Anyosa Luz Mariana. "Estudio de eficiencia energética de la envolvente de un edificio no residencial en un clima tropical." Bachelor's thesis, Pontificia Universidad Católica del Perú, 2019. http://hdl.handle.net/20.500.12404/17687.

Full text
Abstract:
La influencia humana en el sistema climático es evidente: las emisiones que hemos emitido no tienen precedentes en la historia. Es la primera vez desde 1850, que cada año -de los últimos 30- ha sido más caliente que el anterior. Los edificios consumen el 40% de la energía mundial. Según USGBC [1], en Estados Unidos de América, los edificios residenciales y comerciales consumen el 70% de la electricidad del país; por ello, son los segundos responsables de la mayor parte de las emisiones anuales de dióxido de carbono, después de China. La mayoría de esta energía proviene de la combustión de combustibles fósiles para la climatización de los ambientes del edificio y, se calcula que, en los próximos 25 años, las emisiones provenientes de los edificios -y en especial de los comerciales- crecerían a una tasa mayor que en los otros sectores. Este trabajo de fin de máster ha sido realizado en el departamento de arquitectura de la empresa española IDOM Consulting, Engineering and Architecture, con la intención de mostrar la importancia de edificios eficientes energéticamente. Este proyecto se basa en el análisis energético de la envolvente térmica de acuerdo a la normativa de ASHRAE 90.1 2010 de un edificio no residencial de 15 plantas acondicionadas ubicado en Bangkok, por lo que el sistema de climatización se centrará en el sistema de refrigeración. Se empleará el software DesignBuilder v5.3.0.014 –que cuenta con EnergyPlus para predicciones fiables- tanto para el modelo del edificio y el análisis.
APA, Harvard, Vancouver, ISO, and other styles
38

Salas, Vela Sandro. "Cálculo y selección del sistema de abastecimiento de gas natural para climatización en hoteles - aplicación al Hotel Próceres, distrito de San Juan de Lurigancho." Bachelor's thesis, Universidad Nacional Mayor de San Marcos, 2016. https://hdl.handle.net/20.500.12672/6946.

Full text
Abstract:
El documento digital no refiere un asesor
Publicación a texto completo no autorizada por el autor
Calcula la red interna de abastecimiento de gas natural y selección del equipo, para que puedan ser utilizados en termas, cocinas y calentador de piscina en hoteles. Para ello elabora el esquema de distribución interna de GN, calcula la red interna de distribución de gas, selecciona de termas y calentador de agua para la piscina del hotel y calcula las caídas de presiones en la red interna de gas natural.
Trabajo de suficiencia profesional
APA, Harvard, Vancouver, ISO, and other styles
39

Corbacho, Morales Jose Antonio. "Diseño y climatización de un casa residencial mediante una bomba de calor geotérmica de muy baja temperatura en la ciudad de Lima-La Molina." Bachelor's thesis, Universidad Nacional Mayor de San Marcos, 2018. https://hdl.handle.net/20.500.12672/8712.

Full text
Abstract:
Publicación a texto completo no autorizada por el autor
El documento digital no refiere asesor
El continuo aumento de demanda energética que se viene desarrollando año tras año en Perú, lleva a implementar nuevos sistemas de energía renovable para poder satisfacer las necesidades de confort climático. Para este caso se utiliza una energía renovable que se encuentra en la corteza terrestre y que a una cierta profundidad la temperatura es constante, un sistema basado en energía geotérmica, utilizando esta energía como una fuente inagotable que puede ser extraída de la tierra por medio del bombeo de fluidos calentados en su interior, aprovechando su gran inercia térmica. Es por ella que el objetivo de la investigación es el diseño de una vivienda familiar con las condiciones de confort óptimas para los residentes durante todo el año. Para esto se diseñara y dimensionara una instalación geotérmica para suministro de calefacción, refrigeración y agua caliente sanitaria (ACS) mediante una bomba de calor geotérmica. Este dimensionamiento se incluye los sondeos geotérmicos y la selección de la bomba de calor. Cumpliendo con las condiciones básicas del CTE y del RITE durante todo el proceso.
Trabajo de suficiencia profesional
APA, Harvard, Vancouver, ISO, and other styles
40

Salas, Vela Sandro, and Vela Sandro Salas. "Cálculo y selección del sistema de abastecimiento de gas natural para climatización en hoteles - aplicación al Hotel Próceres, distrito de San Juan de Lurigancho." Bachelor's thesis, Universidad Nacional Mayor de San Marcos, 2016. http://cybertesis.unmsm.edu.pe/handle/cybertesis/6946.

Full text
Abstract:
El documento digital no refiere un asesor
Publicación a texto completo no autorizada por el autor
Calcula la red interna de abastecimiento de gas natural y selección del equipo, para que puedan ser utilizados en termas, cocinas y calentador de piscina en hoteles. Para ello elabora el esquema de distribución interna de GN, calcula la red interna de distribución de gas, selecciona de termas y calentador de agua para la piscina del hotel y calcula las caídas de presiones en la red interna de gas natural.
Trabajo de suficiencia profesional
APA, Harvard, Vancouver, ISO, and other styles
41

Figueredo, Gustavo Raúl. "Caracterización experimental y modelización de una enfriadora de absorción de simple/doble efecto de h2o-libr con accionamiento a dos temperaturas para climatización de edificios." Doctoral thesis, Universitat Rovira i Virgili, 2012. http://hdl.handle.net/10803/119330.

Full text
Abstract:
Durante la última década se produjo un enorme crecimiento de la implantación de la climatización de edificios, motivada por el aumento de los requerimientos de confort y de productividad de la población, entre otras causas. Los equipos de climatización más difundidos se accionan mediante energía eléctrica, lo que combinado con la gran simultaneidad de la demanda de climatización y su elevado consumo, provocan puntas de demanda de electricidad que sobrecargan las redes y frecuentemente ocasionan cortes de suministro eléctrico. Los sistemas de climatización basados en máquinas de absorción son una alternativa para disminuir la demanda de electricidad para climatización durante el verano y utilizar las redes de distribución de gas natural que en dicha temporada se encuentran generalmente ociosas. Además las máquinas de absorción, al ser activadas térmicamente, pueden utilizar calor proveniente de plantas solares o calor residual de procesos. Lo que puede llevar a una reducción del consumo de energía primaria y a una disminución de la emisión de gases de efecto invernadero asociados a la climatización. No obstante, para llegar a concretar esta posibilidad, se debe efectuar una selección cuidadosa de la tecnología a utilizar y un diseño muy delicado; dado que se observó que algunas plantas de climatización solar consumen, a lo largo del año, más energía primaria como respaldo que una planta de climatización accionada mediante energía eléctrica. Los sistemas de climatización solar actuales basados en equipos de simple efecto difícilmente pueden llegar a competir con los sistemas de refrigeración por compresión más eficientes, no solo en coste económico sino incluso en reducción del consumo de energía primaria. Es por ello que sería conveniente desarrollar sistemas de doble efecto o combinados de simple/doble efecto que permitan incrementar el aprovechamiento de la energía solar térmica disponible. El objetivo principal de esta tesis es el modelado y el ensayo de una enfriadora de agua por absorción de simple/doble efecto, de agua/LiBr que puede activarse a dos niveles de temperatura. En esta tesis se investigan las características de los ciclos de refrigeración con activación térmica a dos temperaturas en general y, en particular, un prototipo de máquina de refrigeración por absorción de doble etapa basado en el par H2O-LiBr con accionamiento mediante agua caliente a 165ºC como doble efecto y simultáneamente a 165ºC y 90ºC, en modo combinado de simple/doble efecto. En todos los casos con disipación mediante torre de enfriamiento y producción de agua fría a aproximadamente 6ºC. Este equipo permite emplear energía solar térmica para aportar calor al generador de baja temperatura y presión, y cuando este calor no está disponible, el calor auxiliar necesario para suplirlo se puede suministrar a más alta temperatura con lo que el equipo puede operar a un COP más elevado. Se desarrollaron cuatro modelos que enumerados en orden de complejidad creciente son el modelo reversible, endorreversible, termodinámico y térmico detallado. El modelo reversible es un modelo muy simple, totalmente ideal y solo acota las eficiencias a un máximo ideal en función de las temperaturas. El modelo endorreversible considera las irreversibilidades producidas en los intercambios de calor entre el exterior y el interior del ciclo, permitiendo evaluar someramente la distribución del área total de intercambio de calor entre los componentes principales de una máquina; acotando además la potencia máxima de refrigeración. En el modelo termodinámico se consideran, además de las irreversibilidades externas, las principales irreversibilidades internas, asociadas a flujos de calor y flujos de materia, permitiendo estudiar la distribución de áreas y reproduciendo fielmente la variación de la eficiencia con la potencia de refrigeración. En el último modelo, el denominado térmico detallado, se introducen las propiedades de la mezcla H2O-LiBr, las ecuaciones de transmisión de calor y los balances de materia y energía; lográndose predecir el comportamiento de la máquina, los diferentes estados por los que evoluciona la mezcla, y los flujos de materia y energía. Al comparar la distribución de superficies de intercambio de calor obtenida mediante los modelos, con la distribución real del prototipo, se observa que en general los modelos asignan mayor superficie al evaporador y menores superficies a los generadores, absorbedor y condensadores. Respecto al COP se obtienen valores de 1.18 para operación solo con accionamiento a alta temperatura y 0.73 con accionamiento solo a baja temperatura con una variación lineal entre ambos casos. Se examinó y reacondicionó integralmente un prototipo de enfriadora de agua por absorción de H2OLiBr, de simple/doble efecto, de 200 kW de potencia de refrigeración. Se diseñó y construyó una instalación experimental para ensayar el prototipo, compuesta principalmente de dos calderas, torre de enfriamiento y servicios de aire comprimido, entre otros. Se ensayó el prototipo con accionamiento a dos temperaturas y se analizó la influencia de las temperaturas de accionamiento, la temperatura del agua fría y de disipación de calor al ambiente sobre el COP y su variación con la carga de refrigeración. Para procesar la gran cantidad de datos experimentales obtenidos, se utilizó una metodología que combina la reconciliación de datos, con la detección de errores sistemáticos y que permite además la determinación de los errores en los datos reconciliados y su propagación a las variables calculadas. Con accionamiento únicamente a alta temperatura se logró un COP de 1.14 y una potencia de enfriamiento de hasta 160 kW. Para una combinación de potencias de accionamiento de 72 kW a una temperatura de 91ºC, complementada con 80 kW a 157ºC se logró una potencia de enfriamiento de 134 kW exhibiendo un COP de 0.87. Los resultados obtenidos permiten demostrar de forma teórica y experimental la factibilidad técnica y los beneficios del accionamiento de una enfriadora a dos temperaturas.
APA, Harvard, Vancouver, ISO, and other styles
42

Mardones, Barrientos Carlos César. "Comparación entre los ciclos de refrigeración por compresión de vapor y absorción mediante la primera y segunda ley de la termodinámica en aplicaciones de climatización y refrigeración." Tesis, Universidad de Chile, 2016. http://repositorio.uchile.cl/handle/2250/142073.

Full text
Abstract:
Ingeniero Civil Mecánico
El uso de energía es vital para cualquier proceso industrial. Hoy en día se hace necesario utilizar la energía eficientemente. Para esto se requiere optimizar los recursos utilizados en su producción, como disminuir pérdidas e incluso mejorar los procesos que se usan para aquello. En este trabajo se comparan los ciclos de refrigeración por compresión de vapor y de absorción, mediante un análisis energético y exergético para obtener los puntos de mejor desempeño y de menores irreversibilidades en aplicaciones de climatización y refrigeración. Luego de realizar los balances de masa, energía y exergía y seleccionar los fluidos de trabajo, siendo amoniaco para el ciclo por compresión de vapor y una mezcla de amoniaco-agua para el ciclo de absorción, se desarrollan los modelos para los ciclos. Los modelos se necesitan validar reproduciendo los resultados de la literatura. Se encuentra una buena concordancia entre ellos, con errores no mayores al 3%. Para encontrar los parámetros de mejores desempeños de ambos ciclos, se realiza un análisis de sensibilidad del COP y del rendimiento exergético, además de las irreversibilidades que se generan en ambos ciclos. Se encuentra que para el ciclo de refrigeración por compresión de vapor, el aumento de la temperatura del evaporador implica un aumento en el COP del ciclo, una disminución en el rendimiento exergético al igual que en las irreversibilidades del ciclo. Cuando se tiene una menor temperatura del condensador, mejores serán el COP y el rendimiento exergético, mientras que la irreversibilidad será menor. Ahora bien, para el ciclo de refrigeración por absorción, al variar la temperatura del evaporador se encuentra que para aplicaciones de refrigeración (T_e<-10°C), se necesitan temperaturas del generador altas (T_g~140°C), mientras que para aplicaciones de climatización temperaturas bajas del generador (T_g~80°C). Variando la temperatura del condensador, es necesario tener bajas temperaturas para obtener mejores desempeños. De manera similar a la del condensador, la temperatura del absorbedor debe ser baja para que los desempeños del ciclo sean los mejores. Luego de encontrar los parámetros adecuados para obtener los mejores desempeños de los ciclos de refrigeración, la comparación entre ellos, permite inferir tanto para aplicaciones de refrigeración como de climatización, que el ciclo por compresión de vapor tiene mejores resultados para el COP. En cuanto al rendimiento exergético, sólo para temperaturas bajas del generador (T_g<60°C) se obtiene un mejor desempeño sólo en aplicaciones de climatización. De igual forma a lo anterior ocurre con las irreversibilidades.
APA, Harvard, Vancouver, ISO, and other styles
43

Rodríguez, Núñez Víctor Manuel. "Diseño y análisis técnico-económico de un sistema de climatización urbana con aprovechamiento de geotermia de baja entalpía en un proyecto de viviendas de integración social en Chile." Tesis, Universidad de Chile, 2015. http://repositorio.uchile.cl/handle/2250/137569.

Full text
Abstract:
Ingeniero Civil Mecánico
Esta memoria surgió como un trabajo anexo a la investigación de la profesora Dra. Beatriz Maturana Cossio del Instituto de la Vivienda de la Facultad de Arquitectura de la Universidad de Chile, a través del proyecto Fondecyt Nº11130636: "Viviendas de Integración Social y la Sustentabilidad Medio Ambiental: una Investigación de Proyectos Claves en Chile". Esta investigación le permitió al estudiante ubicarse en un contexto real para aplicar una solución de ingeniería y eficiencia energética, la cual consiste en el diseño y estudio de pre-factibilidad de un sistema de bombas de calor geotérmicas para ser utilizado en la climatización de 2.088 viviendas de integración social que componen el proyecto San Alberto de Casas Viejas en Puente Alto, Santiago. El informe aborda los antecedentes necesarios para identificar la tecnología de interés. Se describe qué se entiende por geotermia de baja entalpía y su aprovechamiento por medio de bombas de calor. Con respecto a la metodología, se calcula la demanda energética para la climatización de las viviendas, y se determina el caudal de agua necesario que se debe bombear desde la fuente geotermal para suministrar de energía los sistemas de bombas calor. Luego, se modela el efecto que tiene en el acuífero la reinyección de agua más fría en invierno y más caliente en verano, y finalmente se dimensionan y caracterizan los principales componentes del sistema para estimar el costo de inversión, costo de operación y ahorro que determinarán la factibilidad económica de la propuesta. Se obtiene que el costo de inversión para el sistema de calefacción es en promedio de 15 millones de dólares y que el ahorro en el gasto de operación anual es de al menos 58% con respecto al gasto anual en climatización por medios convencionales alternativos. Se concluye que, tanto en un escenario favorable como uno promedio, la inversión se paga en un horizonte de entre 4 y 20 años. Además, es necesario considerar los beneficios sociales en medioambiente, salud y equidad social para justificar la inversión del proyecto, si se quiere, por parte del Estado. Finalmente, se discuten y proponen tres alternativas que lograrían reducir considerablemente el costo de inversión y los gastos de operación.
APA, Harvard, Vancouver, ISO, and other styles
44

Tello, Suárez Ernesto Hernán. "Propuesta para optimizar la productividad del proceso de producción de hilados en una nueva planta textil mediante la implementación de la gestión de mantenimiento del sistema de climatización." Thesis, Universidad Peruana de Ciencias Aplicadas - UPC, 2013. http://hdl.handle.net/10757/315142.

Full text
Abstract:
En la tesis se planteó una propuesta que permitirá optimizar la productividad del proceso de producción de hilados en una nueva planta textil mediante la implementación de la gestión de mantenimiento de su sistema de climatización. En el primer capítulo, se resumió el marco teórico con la exposición general de diversas perspectivas para optimizar el proceso de producción de hilados en la nueva planta textil. En el segundo capítulo, se realizó un diagnóstico del actual proceso de producción de hilados, explicando que no se dispone de un ambiente controlado de temperatura y humedad del aire, todo lo cual afecta a los mayores ingresos que podría tener la empresa, al no poder producir ellos mismos otros tipos de hilados de mayor calidad y valor, como son los hilados finos. Se explicó que el sistema de climatización es crítico en el nuevo proceso de producción de hilados, una parada del sistema de climatización ocasionaría una disminución en la calidad y producción de hilados finos, afectando los ingresos, costos y productividad de la empresa. En el tercer capítulo, se describió el proceso de producción de hilados finos con el sistema de climatización y extracción que tendrá la nueva planta textil; y, se explicó y evaluó la propuesta optimizada de implementar una adecuada y eficiente gestión de mantenimiento del sistema de climatización y extracción. Por último, en el cuarto capítulo, se detallaron las conclusiones y recomendaciones de la propuesta optimizada y se concluye que la gestión de mantenimiento del sistema de climatización y extracción garantizará su óptimo y continuo funcionamiento en el nuevo proceso de producción de hilados y permitirá generar ahorros de costos anuales de US $ 2,063,400, producir 5,500 Kg/día de hilados de título fino del Ne 40 al Ne 80 con mayor valor económico a los productos que exporta la empresa e incrementar su productividad.
APA, Harvard, Vancouver, ISO, and other styles
45

Moreno, Argilés Pere. "Latent heat thermal energy storage units in HVAC systems for energy management." Doctoral thesis, Universitat de Lleida, 2014. http://hdl.handle.net/10803/288212.

Full text
Abstract:
L'objectiu d'aquesta tesi és estudiar l'aplicació de tancs d'emmagatzematge d'energia tèrmica en una bomba de calor convencional. En aquesta tesi s'inclou un estudi experimental on dos tancs d'emmagatzematge d'energia són acoblats a una bomba de calor aigua-aigua amb l'objectiu d'emmagatzemar energia tèrmica per després utilitzar-la per cobrir la demanda de refrigeració d'un cubicle, produint un desplaçament de la corba de la demanda d'hores puntes a hores valls. En aquest estudi s'analitza el comportament tèrmic del tanc i es realitza una comparativa entre la utilització de PCM i aigua com a medis d'emmagatzematge d'energia tèrmica. En aquesta tesi també s'inclou una descripció de sistemes similar publicats a la literatura, un estudi teòric on es descriu un model matemàtic per simular la descàrrega del tanc i un anàlisi d'incerteses dels paràmetres d'entrada, i finalment, un estudi de corrosió de diferents metalls quan treballen en contacte amb PCM aptes per ser utilitzats en sistemes actius de climatització.
El objetivo de esta tesis es estudiar la aplicación de tanques de almacenamiento de energía térmica en una bomba de calor convencional. En esta tesis se incluye un estudio experimental en donde dos tanques de almacenamiento de energía son acoplados a una bomba de calor agua-agua con el objetivo de almacenar energía térmica para posteriormente utilizarla para cubrir la demanda de refrigeración de un cubículo, produciendo un desplazamiento de la curva de la demanda desde las horas punta a las horas valle. En este estudio se analiza el comportamiento térmico del tanque i se realiza una comparativa entre la utilización de PCM i agua como medios de almacenamiento térmico. En esta tesis también se incluye una descripción de sistemas similares publicados en la literatura, un estudio teórico en donde se describe un modelo matemático para simular la descarga del tanque y un análisis de incertidumbres de los parámetros de entrada, y finalmente, un estudio de corrosión de diferentes metales cuando éstos trabajan en contacto con PCM aptos para ser utilizados en sistemas activos de climatización.
The objective of this thesis is to study the application of thermal energy storage tanks (TES) in a standard heat pump. This thesis includes an experimental study where two TES tanks are coupled to a water-to-water heat pump in order to accumulate thermal energy for later use. The system is used for shifting the cooling load of a small house-like cubicle, shifting the load from on-peak to off-peak periods. The thermal behaviour of the TES tank and a comparison between PCM and water as energy storage medium are evaluated in this study. Moreover, this thesis also includes a state-of-the-art review of similar studies found in the literature, a theoretical study where a mathematical model is developed to predict the thermal behaviour of the TES tank during discharging process, an uncertainties analysis of the input parameters, and finally, a corrosion study of different metals when work in contact with potential PCM to be used in HVAC systems.
APA, Harvard, Vancouver, ISO, and other styles
46

"Respuestas térmicas dinámicas en edificios: control térmico a través de la climatización natural." Universitat Politècnica de Catalunya, 1999. http://www.tesisenxarxa.net/TDX-1009106-114411/.

Full text
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!

To the bibliography