Academic literature on the topic 'Climatizadores evaporativos'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Climatizadores evaporativos.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "Climatizadores evaporativos"

1

Jordan, Rodrigo Aparecido, Rodrigo Garófallo Garcia, Sarah Sgavioli, Ítalo Sabião Sanches, Édipo Sabião Sanches, Maria Fernanda de Castro Burbarelli, Bruno Machado Antunes, and Elton Aparecido Siqueira Martins. "Resfriamento da água utilizada em sistema de climatização evaporativo e o desempenho de frangos de corte." Research, Society and Development 10, no. 9 (July 29, 2021): e42310918131. http://dx.doi.org/10.33448/rsd-v10i9.18131.

Full text
Abstract:
Dois aviários foram construídos em escala reduzida distorcida e equipados com climatizadores evaporativos. Em um dos aviários foi utilizado um sistema de refrigeração para resfriar a água utilizada no sistema evaporativo, enquanto no outro, foi utilizada água em condição ambiente. Cada aviário recebeu 125 pintainhos da linhagem Cobb com um dia de idade, as quais foram criadas até os 43 dias. Durante o período do experimento foram monitoradas as condições ambientais dos dois aviários: temperatura e umidade relativa do ar e, temperatura da cama. Também foi monitorada a temperatura superficial das aves. Foi avaliado o peso final, o ganho de peso das aves e a viabilidade criatória. Para a temperatura do ar, temperatura da cama, ganho de peso e peso final, não houve diferenças significativas entre os dois aviários. A umidade relativa foi menor para o aviário que operou com água resfriada no climatizador evaporativo, o qual apresentou viabilidade criatória de 90,4%, enquanto que no aviário que operou com água em condição ambiente, a viabilidade criatória foi de 86,4%.
APA, Harvard, Vancouver, ISO, and other styles
2

ARJONA LOPEZ, MARCO ANTONIO, and FERNANDO ARTURO RAMIREZ RAMIREZ. "SISTEMA PARA EL AHORRO DE ENERGÍA EN UN CLIMATIZADOR EVAPORATIVO." DYNA INGENIERIA E INDUSTRIA 91, no. 1 (2016): 257–62. http://dx.doi.org/10.6036/7629.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Gomes, Raphaela Christina Costa, Tadayuki Yanagi Junior, Renato Ribeiro de Lima, Sílvia de Nazaré Monteiro Yanagi, Valcimar Ferreira de Carvalho, and Flávio Alves Damasceno. "Predição do índice de temperatura do globo negro e umidade e do impacto das variações climáticas em galpões avícolas climatizados." Ciência Rural 41, no. 9 (September 16, 2011): 1645–51. http://dx.doi.org/10.1590/s0103-84782011005000120.

Full text
Abstract:
Objetivou-se, com o presente trabalho, adaptar e validar um modelo para predição do índice de temperatura de globo negro e umidade (ITGU) no interior de galpões climatizados e analisar o efeito das variações climáticas sobre o ambiente térmico de produção por meio de cenários futuros. Os dados experimentais utilizados para o ajuste e validação do modelo matemático foram coletados em dois galpões avícolas climatizados, equipados com sistema de ventilação em modo túnel negativo e sistemas de resfriamento evaporativo do tipo material poroso umedecido e nebulização. Predições dos valores de ITGU foram estatisticamente iguais às observadas (teste t, P>0,05), com erro de 1,55±1,08%. Considerando o sistema analisado, observou-se que as mudanças climáticas previstas pelos cenários futuros tornarão os ambientes menos propícios à produção de frangos de corte, especialmente nas estações de primavera e verão, nas quais os valores de ITGU foram acima do limite de conforto.
APA, Harvard, Vancouver, ISO, and other styles
4

Rosa, José Francisco, Ilda De Fátima Tinôco, Carlos Magno Fernandes, and Sergio Zolnier. "DIMENSIONAMENTO DE PAINÉIS POROSOS PARA CONDICIONAMENTO DO AR EM AMBIENTES CLIMATIZADOS." REVISTA ENGENHARIA NA AGRICULTURA - REVENG 20, no. 5 (November 6, 2012): 404–11. http://dx.doi.org/10.13083/reveng.v20i5.108.

Full text
Abstract:
Painéis de resfriamento em celulose são comumente empregados no arrefecimento do ar, porém, alguns problemas estão associados a este material. Muitos estudos já concluíram que é viável o uso de materiais alternativos diversos em substituição a celulose, entre eles, aparece como viável, a argila. Em pesquisas anteriormente realizadas foi demonstrado que essa argila possui características favoráveis, que satisfazem as exigências pertinentes a um bom material poroso, podendo substituir, com vantagem econômica, a celulose. Diante do exposto, este trabalho teve como objetivo obter um dimensionamento de placas porosas em argila expandida, que permita, por meio de determinada granulometria da argila e uma espessura do painel, no qual se obtenha melhor eficiência de resfriamento do ar, o emprego em acondicionamento de ambientes em geral. Pelos resultados obtidos, pôde-se concluir que os painéis de argila expandida com granulometria 1 (referência à brita 1) e espessura de 7,7 cm foram os que possibilitaram melhor eficiência de resfriamento adiabático evaporativo para qualquer velocidade do ar compreendida entre 0,44 e 1,28 m/s.
APA, Harvard, Vancouver, ISO, and other styles
5

Costa, Edílson, and Paulo A. M. Leal. "Produção de alface hidropônica em três ambientes de cultivo." Engenharia Agrícola 29, no. 3 (September 2009): 358–69. http://dx.doi.org/10.1590/s0100-69162009000300003.

Full text
Abstract:
Propôs-se avaliar a produção hidropônica de alface-crespa, variedade "Vera", em bancadas inclinadas com canais de 100 mm, utilizando a técnica de filme de solução nutritiva, em resposta à aplicação de dióxido de carbono e ao resfriamento evaporativo. Realizaram-se cinco ciclos de cultivo nos períodos de 20-3 a 17-4-2000 (C1); 25-5 a 29-6-2000 (C2); 13-7 a 21-8-2000 (C3); 27-8 a 2-10-2000 (C4) e 12-12-2000 a 10-1-2001 (C5). Avaliaram-se três casas de vegetação, sendo casa de vegetação sem sistema de resfriamento evaporativo do ar e sem injeção aérea de CO2 (A1); casa de vegetação com injeção aérea de CO2 e sem sistema de resfriamento evaporativo do ar (A2), e casa de vegetação com injeção aérea de CO2 e com sistema de resfriamento evaporativo do ar do tipo meio poroso-exaustor (A3). Avaliaram-se as massas frescas e secas em gramas, o número de folhas e a área foliar em mm². Utilizou-se do delineamento inteiramente casualizado, em que, no ciclo C1, utilizaram-se 48 repetições por ambiente; para os ciclos C2, C3 e C5, foram 64 repetições, e para o ciclo C4, foram 24 repetições. O ambiente climatizado com incremento de dióxido de carbono promoveu melhor desenvolvimento das plantas, com maior número de folhas comercializáveis. Em ambientes não climatizados, o incremento de CO2 não resultou em aumento de produtividade da alface para a maioria dos ciclos. Em épocas de temperaturas mais elevadas, obtiveram-se plantas maiores, com maior número de folhas.
APA, Harvard, Vancouver, ISO, and other styles

Dissertations / Theses on the topic "Climatizadores evaporativos"

1

Pereira, João Marcello. "Avaliação de desempenho do painel de plástico PET para resfriamento evaporativo." reponame:Repositório Institucional da UnB, 2017. http://repositorio.unb.br/handle/10482/31082.

Full text
Abstract:
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Mecânica, 2017.
Submitted by Gabriela Lima (gabrieladaduch@gmail.com) on 2017-11-29T16:02:05Z No. of bitstreams: 1 2017_JoãoMarcelloPereira.pdf: 23374789 bytes, checksum: 8aeed650e1a699e9627b14409669f073 (MD5)
Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2018-01-24T15:43:19Z (GMT) No. of bitstreams: 1 2017_JoãoMarcelloPereira.pdf: 23374789 bytes, checksum: 8aeed650e1a699e9627b14409669f073 (MD5)
Made available in DSpace on 2018-01-24T15:43:19Z (GMT). No. of bitstreams: 1 2017_JoãoMarcelloPereira.pdf: 23374789 bytes, checksum: 8aeed650e1a699e9627b14409669f073 (MD5) Previous issue date: 2018-01-24
O conforto térmico é um aspecto importante na vida das pessoas, pois influencia não só o sentimento de conforto, mas também o desempenho no trabalho, a saúde e a qualidade de vida. Uma alternativa ao condicionamento de ar convencional por compressão de gás é o resfriamento evaporativo direto. O resfriamento evaporativo direto consiste na utilização da evaporação de água na presença de uma corrente de ar, com consequente redução da temperatura do ar sem redução da entalpia. Tem como atrativos o baixo consumo de energia e facilidades de manutenção e não utiliza gases HCFC. Este processo possui como principal característica o fato promover maior conforto térmico em climas quentes e secos. Isto significa que no Brasil, de acordo com o mapa de condição climática formatado pelo IBGE, apresenta potencial favorável ao resfriamento evaporativo em grande parte de nosso território, principalmente nas regiões centro-oeste e nordeste em função das altas temperaturas e baixa umidade maior parte do ano. Além disto, nestas regiões é maior a concentração de pessoas de baixa renda que necessitam de climatização ambiente de baixo custo. Apesar de eficiente, os climatizadores evaporativos diretos comerciais apresentam alto custo de aquisição devido, em grande parte, ao custo de fabricação do painel evaporativo de celulose resinada corrugada. Outros materiais, como a serragem de madeira, a argila expandida e as fibras naturais, apresentam rendimento inferior painel comercial, difícil modelagem e portabilidade, e baixa durabilidade. Dessa forma, uma alternativa sustentável e viável é a utilização do plástico PET (Polietileno tereftalato) como painel evaporativo. O PET é usado principalmente em embalagens de alimentos e, apesar de sua versatilidade, sua disposição é um problema ecológico significativo. O plástico PET na forma original é muito hidrófobo, ou seja, apresenta baixíssima absorção e retenção de água. No entanto, quando sua superfície é tratada mecanicamente (lixamento), há a formação de sulcos e escamas que permite ao material reter uma fina camada (filme) de água na superfície. Esta camada de água troca calor e massa em contato com a corrente de ar evaporando-se, de tal forma que ar após o painel apresenta temperatura de bulbo seco inferior ao ar de entrada. Neste trabalho, amostras de PET foram lixadas utilizando quatro tipos de lixas com três granulações diferentes a fim de determinar qual tipo de lixa e granulação provoca na superfície do PET a maior quantidade de água retida. Em seguida, foram construídos e avaliados painéis evaporativos de filetes de garrafas PET e celulose em bancada condicionadora de ar quanto à eficiência de resfriamento, redução de temperatura de bulbo seco e perda de carga, em diferentes pontos de temperatura e umidade relativa do ar.
Thermal comfort is an important aspect of people's lives, as it influences not only the feeling of comfort, but also the performance at work, health and quality of life. An alternative to conventional gas compression air conditioning is direct evaporative cooling. The direct evaporative cooling consists in the use of water evaporation in the presence of a stream of air, with consequent reduction of the temperature of the air without reduction of the enthalpy. It has attractive low energy consumption and maintenance facilities and does not use HCFC gases. This process has as main characteristic the fact to promote greater thermal comfort in hot and dry climates. This means that in Brazil, according to the climate condition map formatted by IBGE, it has favorable potential for evaporative cooling in most of our territory, mainly in the central-west and northeast regions due to high temperatures and low humidity most of the year. In addition, in these regions, there is a greater concentration of low-income people who need low-cost air conditioning. Although efficient, direct commercial evaporative air conditioners have a high cost of acquisition due, in large part, to the manufacturing cost of the evaporative corrugated cellulose Panel. Other materials, such as wood sawdust, expanded clay and natural fibers, feature lower yield commercial panel, difficult modeling and portability, and low durability. Thus, a sustainable and viable alternative is the use of PET plastic (polyethylene terephthalate) as an evaporative panel. PET is mainly used in food packaging and, despite its versatility, its disposition is a significant ecological problem. The PET plastic in the original form is very hydrophobic, that is, it presents very low absorption and retention of water. However, when its surface is mechanically treated (sanding), there is the formation of grooves and scales which allows the material to retain a thin layer (film) of water on the surface. This layer of water exchanges heat and mass in contact with the stream of air evaporating in such a way that air after the panel presents dry bulb temperature lower than the incoming air. In this work, PET samples were sanded using four types of sandpaper with three different granulations in order to determine which type of sandpaper and granulation causes the largest amount of water retained on the PET surface. Then, evaporative panels of PET bottles and cellulose pulps were constructed and evaluated in air conditioners for cooling efficiency, dry bulb temperature reduction and pressure drop at different temperature and relative humidity points.
Le confort thermique est un aspect important dans notre vie, car il influence non seulement le sentiment de confort, mais aussi la performance du travaille, la santé et la qualité de vie. Une alternative au conditionnement d‘air classique par compression du gaz est le refroidissement par évaporation directe. Le refroidissement évaporatif consiste à l’utilisation d’évaporation de l’eau en présence d‘un courant d’air, avec conséquente réduction de la température de l‘air sans diminution de l’enthalpie. Attrayant pour sa faible consommation d‘énergie, l’entretien des installations et surtout n’utilize pas les gaz de HCFC. La principale caractéristique de ce processus c’est de promouvoir un plus grand confort thermique dans les climats chauds et secs. Au Brésil, la carte des conditions climatiques formatées par l‘IBGE, montre le potentiel en faveur du refroidissement évaporatif en grande partie de notre territoire, en particulier dans les régions du midwest et du nord-est en raison des températures élevées et faible humidité la plupart de l’année. En outre, ces régions concentrent la plus grande partie de personnes à faible revenu qui ont besoin d’air conditionné à faible coût. Bien qu‘éfficace, les climatiseurs commerciaux ont un coût élevé d’acquisition due en grande partie au coût de fabrication du panneau de cellulose ondulé par évaporation enduite de résine. D‘autres matériaux tels que la sciure de bois, l’argile expansée et de fibres naturelles présentent um rendement inférieur au panneau commercial, difficile modélisation et portabilité, et une faible durabilité. Ainsi, une alternative viable et durable consiste à utiliser le plastique PET (polyéthylène téréphtalate) en tant que panneau d’évaporation. Le PET est principalement utilisé dans les emballages alimentaires et, en dépit de leur polyvalence, leur élimination est un problème écologique important. Le PET dans sa forme originale est hydrophobe (faible rétention d‘eau). Le plastique PET dans sa forme originale est très hydrophobe, à savoir, il a une très faible absorption et rétention d’eau. Cependant, lorsque sa superficie est traitée mécaniquement (sablage), on observe la formation d‘arêtes et des écailles du matériau à retenir une couche mince (film) de l’eau sur la superficie. Cette couche d‘eau en échange de chaleur en contact avec l’air, évapore, de sorte que le panneau est équipée de la température de bulbe sec inférieure à l‘air d’entrée. Dans cet travail, des échantillons de PET ont été poncés à l‘aide de quatre types de papier de verre avec trois granulations différentes pour déterminer quel type de papier de verre et granulation provoque sur la superfície du PET la plus grande quantité d’eau retenue. Ensuite, les panneaux évaporatifs de filets de bouteilles en PET et cellulose ont été construits et évalués avec l’objectif de connaître l‘efficacité de refroidissement, la réduction de température de bulbe sec, la perte de charge em diférrents points de la température et l’humidité relative de l’air.
APA, Harvard, Vancouver, ISO, and other styles
2

Silva, Cláudio Elias da. "Comparação de painéis evaporativos de argila expandida e celulose para sistema de resfriamento adiabático do ar em galpões avícolas com pressão negativa em modo túnel." Universidade Federal de Viçosa, 2002. http://www.locus.ufv.br/handle/123456789/9443.

Full text
Abstract:
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2017-02-08T10:41:27Z No. of bitstreams: 1 texto completo.pdf: 1864007 bytes, checksum: 435b6c6b53ff6070167a006ea43267c6 (MD5)
Made available in DSpace on 2017-02-08T10:41:27Z (GMT). No. of bitstreams: 1 texto completo.pdf: 1864007 bytes, checksum: 435b6c6b53ff6070167a006ea43267c6 (MD5) Previous issue date: 2002-11-25
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
Em regiões de climas tropicais e subtropicais, a exemplo do Brasil, os altos valores de temperatura e umidade relativa do ar, sobretudo no verão, têm se mostrado como fatores que mais afetam a produção de frango de corte. Visando promover o arrefecimento térmico e melhorar o ambiente interno das instalações, a avicultura industrial brasileira vem adotando sistemas climatizados com ventilação em modo túnel associados a sistema de resfriamento evaporativo composto de placas de material poroso umedecido por gotejamento ou aspersor. Usualmente são empregados neste sistema placas de celulose as quais, embora tenham mostrado satisfatório desempenho no arrefecimento do ar, apresentam diversos problemas, tais como: custo elevado (cerca de 11% do total do investimento), baixa durabilidade e dificuldade de aquisição, pois se trata de material importado. Assim, esta pesquisa teve como objetivo estudar a possibilidade de substituição da celulose por argila expandida (comercialmente denominada cinasita) a qual é produto alternativo e de custo reduzido e facilmente obtido no Brasil. O experimento se deu em condições de verão, durante os meses de fevereiro e março de 2001, em instalações avícolas da COOPERVALE Ltda, situada na cidade de Palotina, Paraná. Esta pesquisa foi desenvolvida visando a comparação do efeito dos painéis de celulose e de argila expandida (confeccionada conforme recomendação prática) no conforto térmico ambiente e no desempenho produtivo de frangos de corte criados em alta densidade de alojamento em galpões avícolas comerciais equipados com sistema de ventilação negativa em modo túnel, associado a resfriamento evaporativo. O conforto térmico ambiente foi avaliado por meio do Índice de Temperatura do Globo Negro e Umidade (ITGU), Carga Térmica Radiante (CTR) e Umidade Relativa do ar (UR), obtido a cada duas horas no intervalo de 8 às 18 horas. O desempenho produtivo de frangos de corte, com idade de 21 a 42 dias de idade, foi obtido semanalmente, tendo sido avaliado; ganho de peso, consumo de ração, peso vivo, conversão alimentar e mortalidade. Avaliou-se também a eficiência dos distintos painéis evaporativos no arrefecimento térmico do ar no interior do galpão (EF). Os resultados foram interpretados estatisticamente por meio de análise de variância e regressão, sendo que as médias dos fatores qualitativos foram comparadas pelos testes F e/ou Tukey, adotando-se níveis de 5% de probabilidade. Com base neste trabalho, conclui-se que os painéis de celulose proporcionaram melhores índices de conforto térmico (ITGU, CTR, UR) e eficiência evaporativa no arrefecimento térmico (EF) do que os de material alternativo, cinasita. A cinasita demostrou bom potencial para utilização como painel evaporativo, entretanto há necessidade de posteriores investigações visando melhor dimensionamento.
In regions with tropical and subtropical climates, such as Brazil, the high values of temperature and air relative humidity (specially during summer) have shown to be the main factors affecting the production of broiler chickens. In order to promote the thermal cooling and improve the internal environment in the facilities, the Brazilian industrial poultry raising has adopted the acclimatized systems provided with tunnel-type ventilation associated to the evaporative cooling system, which consists of porous material plates moistened by either dripping or sprinklers. The cellulose plates have been usually used in this system. Although these plates have shown a satisfactory performance when cooling the air, they present several problems, such a the high cost (about 11% of the total investment) and the low durability and acquisition difficulty, since they are an imported material. So, this research was carried out to study the possibility to replace the cellulose by swollen clay (commercially called “cinasita”), which is an alternative and low-cost product easily obtained in Brazil. The experiment was carried out from February to March 2001, under summer conditions, in the poultry facilities of COOPERVALE Ltda, Palotina, Paraná State. A comparison was performed for the effects of both the cellulose and the swollen clay panels (made according to practical recommendation) upon the thermal environmental comfort and the productive performance of broiler chickens raised at high-density lodging, in poultry commercial hangars provided with negative tunnel-type ventilation system associated to evaporative cooling. The thermal environmental comfort was evaluated by the Black Globe Temperature and Humidity Index (ITGU), Radiant Thermal Charge (CTR) and the Air Relative Humidity (UR), obtained each two hours from 8 to 18 hours. The productive performance of the broiler chickens aged 21 to 42 days was weekly obtained. Evaluation was performed for: weight gain, ration consumption, alive weight, food conversion, and mortality. The efficiency of the different evaporative panels in thermally cooling the air within the hangar (EF) was also evaluated. The results were statistically interpreted by both variance and regression analyses, whereas the averages of the qualitative factors were compared by the tests F and/or Tukey, by adopting the probability levels of 5%. According to the results, the following conclusions were drawn: the cellulose panels provided the best indexes for thermal comfort (ITGU, CTR, UR) and for the evaporative efficiency over thermal cooling (EF) than those of the alternative material (“cinasita”). “Cinasita” showed a good potential to be used as evaporative panel. However, further investigations into a better dimensioning should be made.
Dissertação importada do Alexandria
APA, Harvard, Vancouver, ISO, and other styles

Book chapters on the topic "Climatizadores evaporativos"

1

Santos, Alexandre Fernandes, Marcelo Luiz Hoffmann, Heraldo José Lopes de Souza, and Pedro Dinis Gaspar. "CLIMATIZADORES EVAPORATIVOS INDIRETOS ECOLÓGICOS E POPULARES PARA REDUÇÃO DO ESTRESSE TÉRMICO EM ORDENHADEIRAS PARA HUMANOS E ANIMAIS." In Ampliação e Aprofundamento de Conhecimentos nas Áreas das Engenharias 2, 105–17. Atena Editora, 2020. http://dx.doi.org/10.22533/at.ed.88020220911.

Full text
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!

To the bibliography