Academic literature on the topic 'Complete dentures'
Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles
Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Complete dentures.'
Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.
You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.
Journal articles on the topic "Complete dentures"
Faur, Nicolae, Cristina Bortun, Liviu Marsavina, Anghel Cernescu, and Otilia Gombosi. "Durability Studies for Complete Dentures." Key Engineering Materials 417-418 (October 2009): 725–28. http://dx.doi.org/10.4028/www.scientific.net/kem.417-418.725.
Full textEmera, Radwa Mohsen Kamal, Mohamed Shady, and Mahmoud Almabrouk Alnajih. "Comparison of retention and denture base adaptation between conventional and 3D-printed complete dentures." Journal of Dental Research, Dental Clinics, Dental Prospects 16, no. 3 (November 15, 2022): 179–85. http://dx.doi.org/10.34172/joddd.2022.030.
Full textChaulagain, Rajib, Smriti Narayan Thakur, Srijana Mishra Sapkota, Bibek Khanal, and Anisha Pandey. "Assessment of Denture Cleanliness among Complete Denture Wearer in Chitwan." Journal of College of Medical Sciences-Nepal 19, no. 2 (June 30, 2023): 143–49. http://dx.doi.org/10.3126/jcmsn.v19i2.55332.
Full textOweis, Yara, Nadia Ereifej, Ayah Al-Asmar, and Abdaljaber Nedal. "Factors Affecting Patient Satisfaction with Complete Dentures." International Journal of Dentistry 2022 (April 8, 2022): 1–7. http://dx.doi.org/10.1155/2022/9565320.
Full textSoboleva, Una, and Irena Rogovska. "Edentulous Patient Satisfaction with Conventional Complete Dentures." Medicina 58, no. 3 (February 24, 2022): 344. http://dx.doi.org/10.3390/medicina58030344.
Full textPanchevska, Sanja, Sasho Elenchevski, Nadica Janeva, and Aneta Mijoska. "Satisfaction of complete denture wearers." Medical review 71, no. 7-8 (2018): 247–49. http://dx.doi.org/10.2298/mpns1808247p.
Full textShah, Sanket S., Abhishek Apratim, Manish Sinha, Nidhi Chhaparia, and Abu Abubakkar. "Denture Hygiene Habits among Elderly Patients Wearing Complete Dentures." Journal of Contemporary Dental Practice 14, no. 6 (2013): 1161–64. http://dx.doi.org/10.5005/jp-journals-10024-1468.
Full textPostic, Srdjan. "Design of complete denture reinforced with metal base." Serbian Dental Journal 60, no. 1 (2013): 15–23. http://dx.doi.org/10.2298/sgs1301015p.
Full textLeyssen, Wouter, Noha Abdelaziz, and AD Walmsley. "Mouth preparation for complete dentures." Dental Update 48, no. 10 (November 2, 2021): 851–56. http://dx.doi.org/10.12968/denu.2021.48.10.851.
Full textRauf Shah, Syed Abdul, Shabana Tanveer, Bilal Zaman Babar, Malik Arshman Khan, Sikandar J. Bajwa, Salvan G., and Maryam Khurshid. "Denture Hygiene Habits among Elderly Patients Wearing Complete Dentures." Pakistan Journal of Medical and Health Sciences 15, no. 10 (October 30, 2021): 2679–81. http://dx.doi.org/10.53350/pjmhs2115102679.
Full textDissertations / Theses on the topic "Complete dentures"
Al, Quaran Firas A. M. "Factors influencing the acceptance of complete dentures." Thesis, Queen's University Belfast, 1999. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.287228.
Full textSilva, Manoela Capla de Vasconcellos dos Santos da 1983. "Efetividade da desinfecção por energia de microondas de três resinas acrílicas contaminadas por leveduras do gênero Candida." [s.n.], 2010. http://repositorio.unicamp.br/jspui/handle/REPOSIP/288563.
Full textDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-17T04:26:24Z (GMT). No. of bitstreams: 1 Silva_ManoelaCapladeVasconcellosdosSantosda_M.pdf: 1427757 bytes, checksum: 3e559b527f8ddc7215c4e2a25c440832 (MD5) Previous issue date: 2010
Resumo: Neste estudo o objetivo foi avaliar a efetividade da irradiação por energia de microondas na desinfecção de resinas acrílicas para confecção de próteses totais. Setenta e dois corpos-deprova em resina acrílica de diferentes tipos (Vipi convencional, Vipi Wave e Vipi convencional) foram confeccionados de forma padronizada e submetidos à esterilização com óxido de etileno. Na parte superior dos corpos-de-prova foram inoculados 100 µL do inóculo de uma das três espécies de Candida e posterior colocação em estufa a 37°C por 1 hora e 30 minutos para a realização da primeira aderência. Após este tempo, cada poço foi completado com meio estéril e a placa novamente levada à estufa para incubação a 37°C por 6 horas. Após essa incubação, os 54 corpos-de-prova foram imersos em 10 mL de água estéril e irradiados por energia de microondas a 650 W por 3 minutos. Dezoito corpos-deprova não irradiados foram considerados grupo controle. Após a incubação por 48 horas, tanto as placas das amostras irradiadas quanto as não irradiadas foram submetidas à contagem de colônias em contador de colônias digital. Os números de unidades formadoras de colônias por mililitro foram calculados e comparados estatísticamente para verificação da efetividade do método de desinfecção proposto. As semeaduras das placas de Petri referentes aos corpos-de-prova irradiados (grupo experimental) não apresentaram colônias viáveis para todos os microorganismos avaliados após incubação a 37ºC por 48 horas. Os resultados demonstraram efetiva esterilização após 3 minutos de irradiação a 650 W para todos os corpos-de-prova do grupo experimental. Os corpos-de-prova do grupo controle (não irradiadas) apresentaram crescimento microbiano após 48 horas de incubação. A irradiação por microondas a 650 W por 3 minutos mostrou ser um método efetivo na esterilização dos corpos-de-prova inoculados com C. albicans, C. dubliniensis e C. tropicalis
Abstract: The objective of this study was to evaluate the effectiveness of microwave irradiation in the disinfection of acrylic resins for the fabrication of dentures. Seventy two specimens of acrylic resin of different types were made in a standardized and subjected to sterilization with ethylene oxide. The specimens were individually inoculated with100 µL of inoculums of three species of Candida, and later placed in an incubator at 37°C for 1 hour and 30 minutes to perform the first adhesion. After this time, each well was supplemented with sterile media and the plate once again brought to a stove for incubation at 37°C for 6 hours. After this incubation, the 54 specimens were immersed in 10 mL of sterile water and irradiated by microwave energy at 650 W for 3 minutes. Eighteen specimens were considered non-irradiated control group. After incubation for 48 hours, both plates of the irradiated samples as the non-irradiated were subjected to counting of colonies in colony digital counter. The number of colonies forming units per milliliter were calculated and compared to verify the effectiveness of the proposed method of disinfection. Cultivation of Petri plates relating to specimens irradiated (experimental group) showed no viable colonies for all microorganisms assessed after incubation at 37°C for 48 hours. The results demonstrated effective sterilization after 3 minutes of irradiation at 650W for all specimens the experimental group. Petri plates sown with the bodies corresponding specimens control group (not irradiated) showed microbial growth after 48 hours of incubation. A microwave irradiation at 650 W for three minutes proved to be an effective method of sterilization of the specimens inoculated with C. albicans, C. dubliniensis and C. tropicalis
Mestrado
Protese Dental
Mestre em Clínica Odontológica
Murray, Michael Dominic. "Physical aspects of complete denture retention." Thesis, [Hong Kong] : Faculty of Dentistry, University of Hong Kong, 1989. http://sunzi.lib.hku.hk/hkuto/record.jsp?B12555009.
Full textAhmed, Rukshana. "Do patients' expectations influence their satisfaction with complete dentures?" University of the Western Cape, 2016. http://hdl.handle.net/11394/5601.
Full textBackground: Most edentulous patients have expectations regarding complete dentures that are not only dependant on past experiences but also the information they received from others. These expectations may impact on the level of satisfaction the patient would have when receiving their complete dentures. When determining levels of satisfaction, factors such as comfort, speech, aesthetics, mastication, retention, fit / stability and occurrence of pain should be assessed. The dental student should be able to clinically apply theoretical knowledge to provide the patient with a stable and retentive denture that fulfils their expectations on function and aesthetics. Not much has been written regarding this link between patients' expectations and satisfaction with complete dentures at the University of the Western Cape, thus it warranted further investigation. Aim: The aim of this study was to determine whether patients' expectations influence their satisfaction with new complete dentures constructed by undergraduate dental students. Objectives:- 1. To determine the expectations of the edentulous patients prior to receiving new complete dentures. 2. To determine if patients’ expectations influences satisfaction with new complete dentures. 3. To investigate the influence of socio-demographic factors on patients' satisfaction wearing complete dentures. 4. To determine if the level of experience of the undergraduate student influences patient satisfaction. Methodology: This was an observational study using two questionnaires for data collection namely the Patient Expectation Questionnaire and the Oral Health Impact Profile- 20. Socio-demographic data was collected as part of the first questionnaire. Each participant was given an individual case number that corresponded on both questionnaires. This facilitated correlation between the expectations and satisfaction results of individual patients. Results: The age range for the majority of the patients was between 56-65 years. Females made up 72% of the sample with 85% of the sample of coloured ethnicity. Statistical analysis included reliability testing of the Patient Expectation Questionnaire and the Cronbach's Alpha of .773 was recorded, which indicates good reliability. Results following analysis of the Oral Health Impact Profile-20 showed high levels of satisfaction in most domains. The correlation between patients' expectations and satisfaction with new complete dentures was not proven using Pearson correlation. However, the comparison between the expectations questionnaire and Oral Health Impact Profile-20 frequency distribution showed positive results and most expectations of the patient were met or even exceeded for certain domains. Conclusion: Once analysis of both questionnaires was completed high levels of expectations were recorded and these expectations were met in most domains. Even though the statistical relationship between patient expectations and satisfaction was not proven, analysis of the questionnaires yielded positive results. No association was found between pre-treatment expectation and patient satisfaction with complete dentures. Some socio-demographic factors influenced patient satisfaction with complete dentures. High levels of patient satisfaction were recorded regardless of the clinical experience of the undergraduate dental student.
Geerts, Greta Aimée Virginie Maria. "The neutral zone for mandibular complete dentures : a clinical trial." Thesis, University of the Western Cape, 2016. http://hdl.handle.net/11394/5025.
Full textRehabilitation of edentulous jaws without the option of osseointegrating implants will remain the only treatment option within reach of many older patients for the foreseeable future. Many routine prosthodontic procedures are based on dogmas, because no high-level scientific evidence exists to either accept or reject them, among these is the “neutral zone” (NZ) concept. In spite of paucity of evidence using approved patient-based outcome instruments, it is generally agreed that the NZ should be respected when constructing complete dentures. The purpose of this research project was to determine how shapes of conventional and NZ mandibular dentures differ, and if the two different types of dentures impact differently on oral health–related quality of life by using an accepted oral health-related quality of life instrument as a patient-based outcome. Thirty nine edentulous patients were selected for this prospective, randomised, cross-over, single-blinded clinical trial. Two sets of complete dentures were made for each patient. One denture set was made following conventional biometric guidelines for determining the position of the mandibular posterior denture teeth in relation to the ridge; another set was made following a functional impression of the potential denture space. Each set of dentures was worn for at least two months. A similar number of types of dentures were delivered first. Widths of residual ridges and mandibular denture arches were measured using digital measuring software. Position of denture teeth was related to the ridge. Denture dimensions were compared by means of analysis of variance using the mixed procedure. Using formula of parabola, arch-widths were compared using paired t-tests. Pre- and post-treatment patient feedback was obtained by means of the 20-item Oral Health Impact Profile (OHIP-20) and a preference score. Treatment effect size (ES) was established based on the OHIP-20 scores. Relevant associations among denture dimensions, OHIP-20 scores, preference, age, gender, marital status, education, income, period of edentulousness, and quality of denture-bearing tissue were done using the generalised linear model and correlation analysis. For all statistical analysis, level of significance was determined at p<0.05. The mean age of the sample was 62.3 years. Twenty four patients were female. Mean period of edentulousness was 31 years and mean number of denture sets worn prior to the trial was 2.5. Except for the canine region, NZ dentures were statistically wider than anatomic dentures. The difference in mean widths between the two types of dentures was larger for female patients. Older patients had smaller differences in denture dimensions. More unfavourable denture-bearing tissue was associated with a larger difference in the two types of dentures. Both types of mandibular dentures significantly improved the OHRQoL of patients. Both types of dentures had a high treatment ES. The OHIP-20 instrument could not distinguish a statistical difference in impact on OHRQoL between the two treatment options. There was a minute difference in treatment ES between the two types of treatment. The only domain representing a small clinical benefit between NZ and anatomic dentures was “physical pain”, with the NZ dentures scoring better. There was no correlation between pre- and post-treatment scores for both types of dentures. No significant associations were found between post-treatment OHIP- 20 scores on the one hand and tissue scores, gender, age, education, marital status, period of edentulousness and denture dimension differences on the other hand. Based on OHIP-20 scores, there was a significant association between denture preference and NZ dentures, but not for the other preferences. No significant associations were found between denture preferences on the one hand and tissue scores, gender, age, period of edentulousness and denture dimension differences on the other hand. Even though no significant relationship was found between preference and gender, the majority of female patients preferred the NZ denture and the majority of male patients did not express a preference. Providing new complete dentures improved OHRQoL of edentulous patients. The majority of female patients preferred the NZ compared over the ANA denture. The NZ technique appeared to have a higher positive impact on OHRQoL of female patients compared to male patients.
Saponaro, Paola Cristina. "Clinical performance of CAD/CAM fabricated complete dentures; A retrospective study and assessment of patient satisfaction." The Ohio State University, 2015. http://rave.ohiolink.edu/etdc/view?acc_num=osu1438885753.
Full textMcNaugher, Gillian A. "Developing a community index of complete denture treatment need." Thesis, Queen's University Belfast, 1999. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.300775.
Full textFerreira, Daniel Filgueiras. "Avaliação eletromiografica da eficiencia de duas tecnicas de montagem de dentes artificiais em protese total dupla." [s.n.], 2005. http://repositorio.unicamp.br/jspui/handle/REPOSIP/289924.
Full textDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-04T05:56:39Z (GMT). No. of bitstreams: 1 Ferreira_DanielFilgueiras_M.pdf: 1227737 bytes, checksum: 8574e46d80b04a8d94d10a74cac5fef3 (MD5) Previous issue date: 2005
Resumo: O objetivo desta pesquisa foi avaliar eletromiograficamente o padrão de atividade muscular resultante da utilização de duas técnicas de montagem de dentes artificiais para obtenção de equilíbrio em prótese total dupla. Vinte e quatro pacientes totalmente edêntulos, livres de sinais e sintomas de Desordem Temporomandibular (DTM) com no mínimo cinco anos de uso de próteses totais, foram separados em dois grupos de 12 pacientes: (G1 e G2). Para o G1, utilizou-se a técnica Convencional, onde o equilíbrio foi obtido através de contatos interferentes entre dentes artificiais. Para o G2, utilizou-se a técnica das Rampas Posteriores de Nóbilo, que proporciona equilíbrio através de contatos deslizantes entre a superfície das rampas. O padrão de atividade muscular foi mensurado através da atividade eletromiográfica (EMG) dos músculos temporais porção anterior e masseteres nas posições de repouso (R) e na contração isométrica em máxima intercuspidação (CIMI), avaliado em quatro tempos: T0 - instalação; T1 - 1o mês; T2 - 2o meses; T3 - 3o meses de uso das próteses. Foi utilizado o eletromiógrafo Myosystem I® (Prosecon Ltda, Uberlândia, MG, Brasil) e o sinal eletromiográfico condicionado através de filtro digital passa faixa e analisado em relação RMS (Root Mean Square). Em ambos os grupos, observou-se pequenas alterações nos valores da atividade EMG para os músculos temporais anteriores e masseteres na posição de R. Na posição de CIMI, no G1 os músculos temporais anteriores apresentaram valores finais menores que os iniciais, e situação inversa foi observada para os masseteres, com valores finais maiores que os iniciais; no G2 observou-se inversão dos valores para os músculos temporais anteriores e aumento para os masseteres com ligeiro equilíbrio no terceiro mês de avaliação. O teste Wilcoxon-Mann-Whitney entre as técnicas e o de Friedman nos tempos avaliados não mostraram diferenças estatísticas significativas (p<0.05). Conclui-se que as técnicas estudadas clinicamente não apresentaram diferença entre si, e que as avaliações nos tempos não proporcionaram o equilíbrio dos músculos mastigatórios estudados. Dessa forma, ambas técnicas podem ser utilizadas com performances clínicas semelhantes
Abstract: The aim of this study was to evaluate by the electromyography muscular activity pattern resulting of two prosthetic teeth arrangement techniques that promote balance in double complete dentures. Twenty-four subjects totally edentulous, free from signs and symptoms of TMJ disorders and with at least five years complete dentures use were divided in two groups of 12 subjects: G1 and G2. In the Group 1, the Conventional technique was used and the interference contacts between artificial teeth were responsible for the balance. In the Group 2, the Nóbilo's Balancing Ramps technique, slippery contacts between ramps surfaces provided balance. The muscular activity pattern was measured by electromyographic (EMG) activity of anterior temporal and masseter muscles in the mandibular rest (R) and maximal biting in the intercuspal position (CIMI) at four times: T0 - installation; T1 - 1st month; T2 - 2nd month; T3 - 3rd month of prostheses use. The electromyographic sign was collected with Myosystem I® conditioned through of digital filter pass band and analyzed in relation to RMS (Root Mean Square). In both groups, in the mandibular rest of the anterior temporal and masseter muscles was observed small alterations in the EMG activity values. In CIMI position, in the Group 1, anterior temporal muscles showed final values smaller than the initial, differently of masseter muscles that showed final values greater than the initial; in the Group 2 inversion values were observed in the temporal muscles and increase in the masseter with light balance in the third month evaluation. Wilcoxon-Mann-Whitney test between the techniques and the Friedman test in the evaluated times did not show significant statistical differences (p<0.05). The techniques clinically studied did not show differences between themselves and the times evaluation did not provide balance in the masticatory muscles studied. In this way, both techniques can be used with similar clinic performance
Mestrado
Protese Dental
Mestre em Clínica Odontológica
Adam, Razia Zulfikar. "Do complete dentures improve the quality of life of patients?" Thesis, University of the Western Cape, 2006. http://etd.uwc.ac.za/index.php?module=etd&.
Full textoral health-related quality of life. Objectives: The purpose of this study was to investigate the relationship between gender, age, socioeconomic status and denture satisfaction
Ricci, Weber Adad [UNESP]. "Disfunção craniomandibular em pacientes desdentados totais com alteração da dimensão vertical. -." Universidade Estadual Paulista (UNESP), 2002. http://hdl.handle.net/11449/97328.
Full textO presente estudo procurou avaliar a prevalência de sinais e sintomas de disfunção craniomandibular (D.C.M.) em 100 pacientes desdentados totais, portadores de próteses totais duplas, dos quais 58 apresentavam dimensão vertical normal (Grupo 1) e 42 dimensão vertical com alteração (Grupo 2). Os dados foram obtidos a partir de um índice anamnésico simplificado e de exame físico. Após a análise estatística, foi possível observar que: 1. em relação ao índice anamnésico utilizado, a análise estatística mostrou haver associação entre a dimensão vertical e os sintomas de D.C.M. (p=0,016); 2. quanto ao número de regiões sensíveis à palpação muscular, foi constatada uma associação estatisticamente significante com a dimensão vertical (p=0,014); 3. quando avaliados os grupos musculares isoladamente, apenas a palpação intraoral do músculo pterigóideo lateral apresentou associação estatisticamente significante com a dimensão vertical (p=0,05). Conclui-se, por meio deste estudo, que existe uma evidência de associação entre a dimensão vertical e os sinais e sintomas de D.C.M. considerando-se a metodologia empregada e a população estudada.
The present study evaluated the prevalence of signs and symptoms of temporomandibular disorders in 100 patients wearing complete upper and lower dentures, 58 with normal vertical dimension (Group 1) and 42 with altered vertical dimension (Group 2). The data were obtained utilizing a simplified anamnestic index and of physical exam. After the statistical analysis, it was possible to conclude that: 1. there was a significant correlation between the vertical dimension and the symptoms of temporomandibular disorders, when utilizing the anamnestic index (p=0,016); 2. there was a significant correlation between the vertical dimension and the number of tenderness sites during muscle palpation (p=0,014); 3. when appraised the muscular groups separately, just the tenderness to the intra-oral palpation of the lateral pterygoid muscle showed a statistically significant correlation with the vertical dimension (p=0,05). It could be concluded that there was an association between the vertical dimension and the signs and symptoms of temporomandibular disorders, for this sub population that has been analysed.
Books on the topic "Complete dentures"
1934-, Rahn Arthur O., ed. Syllabus of complete dentures. 4th ed. Philadelphia: Lea & Febiger, 1986.
Find full textGeering, Alfred H. Complete denture and overdenture prosthetics. Stuttgart: G. Thieme Verlag, 1993.
Find full textDevlin, Hugh. Complete Dentures. Berlin, Heidelberg: Springer Berlin Heidelberg, 2002. http://dx.doi.org/10.1007/978-3-642-56109-2.
Full textSheldon, Winkler, ed. Essentials of complete denture prosthodontics. 2nd ed. Littleton, Mass: PSG Pub. Co., 1988.
Find full textMacEntee, Michael I. The complete denture: A clinical pathway. Chicago: Quintessence Pub. Co., 1999.
Find full textGrant, Alan A. Complete prosthodontics: Problems, diagnosis and management. London: Wolfe, 1994.
Find full textGrant, Alan A. Complete prosthodontics: Problems, diagnosis and management. London: Wolfe, 1994.
Find full textM, Heartwell Charles, and Heartwell Charles M, eds. Textbook of complete dentures. 5th ed. Philadelphia: Lea & Febiger, 1993.
Find full textBook chapters on the topic "Complete dentures"
Devlin, Hugh. "Treatment Planning: Assessing the Task Ahead." In Complete Dentures, 1–15. Berlin, Heidelberg: Springer Berlin Heidelberg, 2002. http://dx.doi.org/10.1007/978-3-642-56109-2_1.
Full textDevlin, Hugh. "Impression Taking and Mucosal Loading." In Complete Dentures, 17–32. Berlin, Heidelberg: Springer Berlin Heidelberg, 2002. http://dx.doi.org/10.1007/978-3-642-56109-2_2.
Full textDevlin, Hugh. "Determining the Jaw Relationship." In Complete Dentures, 33–61. Berlin, Heidelberg: Springer Berlin Heidelberg, 2002. http://dx.doi.org/10.1007/978-3-642-56109-2_3.
Full textDevlin, Hugh. "The Trial Denture." In Complete Dentures, 63–77. Berlin, Heidelberg: Springer Berlin Heidelberg, 2002. http://dx.doi.org/10.1007/978-3-642-56109-2_4.
Full textDevlin, Hugh. "Fitting the Processed Denture." In Complete Dentures, 79–84. Berlin, Heidelberg: Springer Berlin Heidelberg, 2002. http://dx.doi.org/10.1007/978-3-642-56109-2_5.
Full textDevlin, Hugh. "The Review Appointment." In Complete Dentures, 85–94. Berlin, Heidelberg: Springer Berlin Heidelberg, 2002. http://dx.doi.org/10.1007/978-3-642-56109-2_6.
Full textDevlin, Hugh. "Domiciliary Treatment." In Complete Dentures, 95–105. Berlin, Heidelberg: Springer Berlin Heidelberg, 2002. http://dx.doi.org/10.1007/978-3-642-56109-2_7.
Full textBasker, R. M., J. C. Davenport, and H. R. Tomlin. "Fitting Complete Dentures." In Prosthetic Treatment of the Edentulous Patient, 232–48. London: Palgrave Macmillan UK, 1992. http://dx.doi.org/10.1007/978-1-349-21869-1_13.
Full textYıldız, Coşkun, and Yasemin K. Özkan. "Single Complete Dentures." In Complete Denture Prosthodontics, 243–70. Cham: Springer International Publishing, 2018. http://dx.doi.org/10.1007/978-3-319-69017-9_9.
Full textÖzkan, Yasemin K., Yılmaz Umut Aslan, and Ender Kazazoğlu. "Duplicate (Copy) Dentures." In Complete Denture Prosthodontics, 271–79. Cham: Springer International Publishing, 2018. http://dx.doi.org/10.1007/978-3-319-69017-9_10.
Full textConference papers on the topic "Complete dentures"
SEVBITOV, Andrey, Aleksey DOROFEEV, Sergey MIRONOV, Samer AL-KHOURY, and Anton TIMOSHIN. "PREVENTION OF CANDIDIASIS IN PATIENTS USING REMOVABLE DENTURES." In SOUTHERN BRAZILIAN JOURNAL OF CHEMISTRY 2021 INTERNATIONAL VIRTUAL CONFERENCE. DR. D. SCIENTIFIC CONSULTING, 2022. http://dx.doi.org/10.48141/sbjchem.21scon.04_abstract_sevbitov.pdf.
Full textNegrutiu, Meda L., Cosmin Sinescu, Carmen Todea, and Adrian G. Podoleanu. "Complete denture analyzed by optical coherence tomography." In Biomedical Optics (BiOS) 2008, edited by Peter Rechmann and Daniel Fried. SPIE, 2008. http://dx.doi.org/10.1117/12.767106.
Full textWang, Shujie, Jiwei Zhang, and Wenxia Liu. "A Novel Flexible System for Denture Design and Manufacture." In 2007 IEEE/ICME International Conference on Complex Medical Engineering. IEEE, 2007. http://dx.doi.org/10.1109/iccme.2007.4382091.
Full textFan, Qi-Lei, Xiao-Sheng Cheng, Ning Dai, Cheng Cheng, Ren-kai Huang, and Yu-Chun Sun. "Virtual adjustment of the occlusal surface for complete denture tooth arrangement." In 2015 International Symposium on Bioelectronics and Bioinformatics (ISBB). IEEE, 2015. http://dx.doi.org/10.1109/isbb.2015.7344947.
Full textDughir, Ciprian, Ana Maria Popovschi, Andreea Codruta Cojocariu, Florin Ionel Topala, Meda Lavinia Negrutiu, Cosmin Sinescu, Aldo de Sabata, and Virgil-Florin Duma. "Complete denture base assessments using holograms: dimensional alterations after different activation methods." In Sixth International Conference on Lasers in Medicine, edited by Darinca Carmen Todea, Adrian G. Podoleanu, and Virgil-Florin Duma. SPIE, 2016. http://dx.doi.org/10.1117/12.2191886.
Full textUtami Ritonga, Putri Welda, and Luveena Loshini Prabakaran. "Association of Clinical Evaluation and Patient's Level of Satisfaction among Complete Denture Wearer." In International Dental Conference of Sumatera Utara 2017 (IDCSU 2017). Paris, France: Atlantis Press, 2018. http://dx.doi.org/10.2991/idcsu-17.2018.61.
Full textChen, Xiaojun, Chengtao Wang, and Eryi Lu. "Application and Analysis of Computerized Simulation System of Dynamic Occlusion for Complete Denture." In 2008 2nd International Conference on Bioinformatics and Biomedical Engineering (ICBBE '08). IEEE, 2008. http://dx.doi.org/10.1109/icbbe.2008.725.
Full textChen, Wei-can. "Research on Computerized Simulation of Occlusal Contacts for Complete Denture Based on 3D Digitized Modeling." In 2016 4th International Conference on Machinery, Materials and Computing Technology. Paris, France: Atlantis Press, 2016. http://dx.doi.org/10.2991/icmmct-16.2016.25.
Full textChizhmakov, E. A., S. V. Panin, S. D. Arutyunov, and S. A. Muslov. "PHYSICAL AND MECHANICAL PROPERTIES OF NOLATEK POLYMER AND POLYETHYLENE TEREPHTHALATE USED FOR COMPLETE REMOVABLE DENTURE BASES." In Physical Mesomechanics of Materials. Physical Principles of Multi-Layer Structure Forming and Mechanisms of Non-Linear Behavior. Novosibirsk State University, 2022. http://dx.doi.org/10.25205/978-5-4437-1353-3-306.
Full textConstantiniuc, Mariana, Horatiu Colosi, and Liana Lascu. "Necessary Preliminaries for the Modeling and Numerical Simulation of the Effects of Anterior Teeth Implantation on Complete Denture Stability." In 2006 IEEE International Conference on Automation, Quality and Testing, Robotics. IEEE, 2006. http://dx.doi.org/10.1109/aqtr.2006.254680.
Full textReports on the topic "Complete dentures"
Prajapati, Jinal, Rubina Tabassum, and Gaurang Mistry. Comparison of shear bond strength of artificial teeth used with CAD/CAM PMMA versus heat cure acrylic resins for complete denture manufacturing- a systematic review. INPLASY - International Platform of Registered Systematic Review and Meta-analysis Protocols, November 2023. http://dx.doi.org/10.37766/inplasy2023.11.0065.
Full text