To see the other types of publications on this topic, follow the link: Complexometric Titrations.

Journal articles on the topic 'Complexometric Titrations'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 50 journal articles for your research on the topic 'Complexometric Titrations.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse journal articles on a wide variety of disciplines and organise your bibliography correctly.

1

FERNANDEZ-MAESTRE, Roberto. "THE IMPORTANCE OF TEACHING TITRATION CURVES IN ANALYTICAL CHEMISTRY." Periódico Tchê Química 17, no. 34 (2020): 213–19. http://dx.doi.org/10.52571/ptq.v17.n34.2020.230_p34_pgs_213_219.pdf.

Full text
Abstract:
Titration curves are an essential subject of an Analytical Chemistry course. The main objective of calculating titration curves is the selection of an indicator for such titrations. The calculation of titration errors is imperative because they establish if a given indicator can be used for a given titration. This study reviews the available literature on titration curves and calculating their errors. Its purpose is to draw attention to the importance of undergraduate chemistry students having competencies to determine the titration errors rather than skills to build titration curves as the ul
APA, Harvard, Vancouver, ISO, and other styles
2

Bhavya sri Khagga, Srija Ghanukota, and Sumakanth Mogili. "Novel titrimetric method for the determination of rosuvastatin in pure form." World Journal of Biology Pharmacy and Health Sciences 13, no. 2 (2023): 001–4. http://dx.doi.org/10.30574/wjbphs.2023.13.2.0054.

Full text
Abstract:
In this experiment assay of Rosuvastatin was performed by titrimetric method. The titration performed is a complexometric titration. The complexometric titration used is an easy, inexpensive volumetric titration method. This method is based on rection of calcium with a solution of disodium ethylenediaminotetraacetate (EDTA). Complex of calcium and EDTA is formed. Erichrome black Tis used as an indicator in this complexometric titration. At pH 12-13, Erichrome black T changes the color from pink to blue. The appearance blue color is determined to be the endpoint of this experiment. The titratio
APA, Harvard, Vancouver, ISO, and other styles
3

Bhavya, sri Khagga, Ghanukota Srija, and Mogili Sumakanth. "Novel titrimetric method for the determination of rosuvastatin in pure form." World Journal of Biology Pharmacy and Health Sciences 13, no. 2 (2023): 001–4. https://doi.org/10.5281/zenodo.7948477.

Full text
Abstract:
In this experiment assay of Rosuvastatin was performed by titrimetric method. The titration performed is a complexometric titration. The complexometric titration used is an easy, inexpensive volumetric titration method. This method is based on rection of calcium with a solution of disodium ethylenediaminotetraacetate (EDTA). Complex of calcium and EDTA is formed. Erichrome black Tis used as an indicator in this complexometric titration. At pH 12-13, Erichrome black T changes the color from pink to blue. The appearance blue color is determined to be the endpoint of this experiment. The titratio
APA, Harvard, Vancouver, ISO, and other styles
4

Cassedanne, Jeanníne Odette, and Hamílcar Freire de Carvalho. "Dosagem de chumbo em pequenas quantidades nos minerais." Anuário do Instituto de Geociências 14 (December 1, 1991): 41–43. http://dx.doi.org/10.11137/1991_0_41-43.

Full text
Abstract:
This study describes a lead volumetric titration in minerals. Complexometric accumulation titrations are used and a previous lead separation as chloride is necessary. In the range of 10 to 50 mg of metal, a precision of 0,5 to 0,04% is reached, with a good reproductibility.
APA, Harvard, Vancouver, ISO, and other styles
5

Rajkovic, Milos. "Complexometric determination, Part II: Complexometric determination of Cu2+-ions." Chemical Industry 56, no. 10 (2002): 429–35. http://dx.doi.org/10.2298/hemind0210429r.

Full text
Abstract:
A copper-selective electrode of the coated wire type based on sulphidized copper wire was applied successfully for determining Cu(II) ions by complexometric titration with the disodium salt of EDTA (complexon III). By the formation of internal complex compounds with the Cu(II) ion, the copper concentration in the solution decreases, and all this is followed by a change of potential of the indicator system Cu-DWISE (or Cu-EDWISE)/SCE. At the terminal point of titration, when all the Cu(II) ions are already utilized for the formation of the complex with EDTA, there occurs a steep rise of potenti
APA, Harvard, Vancouver, ISO, and other styles
6

Macca, Carlo, and Mario Fiorani. "Feasibility of complexometric back-titrations." Journal of Chemical Education 63, no. 2 (1986): 121. http://dx.doi.org/10.1021/ed063p121.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Zhai, Jingying, and Eric Bakker. "Complexometric titrations: new reagents and concepts to overcome old limitations." Analyst 141, no. 14 (2016): 4252–61. http://dx.doi.org/10.1039/c6an00538a.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Shyichuk, Alexander, Dorota Ziółkowska, Jan Lamkiewicz, and Maria Kowalska. "Calcium Determination by Complexometric Titration with Calcein Indicator Using Webcam for Endpoint Detection." Water 17, no. 12 (2025): 1757. https://doi.org/10.3390/w17121757.

Full text
Abstract:
Precise and convenient analytical methods are needed for the quantitative determination of calcium in water and food. Complexometric titration remains a reliable technique to determine calcium in milligram amounts. The titrations have been performed automatically by detecting color transitions with a webcam. Classical complexometric indicator calcein provided a sharp color transition. In diffuse reflection mode, the color appearance parameter (Hue) provides better precision and is more resistant to ambient light fluctuations compared to RGB primaries. In fluorescence mode with LED illumination
APA, Harvard, Vancouver, ISO, and other styles
9

Vasilyeva, Marina S., Vladimir S. Rudnev, E. S. Zykova, et al. "Ti/TiO2, Au Electrodes Prepared by Plasma Electrolytic Oxidation and Electron Beam Evaporation." Defect and Diffusion Forum 386 (September 2018): 326–31. http://dx.doi.org/10.4028/www.scientific.net/ddf.386.326.

Full text
Abstract:
Ti/TiO2,Au electrodes were prepared via plasma electrolytic oxidation (PEO) of Ti plate, followed by deposition of a thin (10 nm) Au layer by electron beam evaporation (EBE). The electrodes obtained were used for potentiometric indication of different types of chemical reactions. Ti/TiO2,Au electrodes showed an excellent performance for end point indication in the oxidation-reduction and complexometric titrations similar to the traditional Pt and in the acid-base titration similar to glass electrode.
APA, Harvard, Vancouver, ISO, and other styles
10

Zhai, Jingying, Xiaojiang Xie, and Eric Bakker. "Ionophore-based ion-exchange emulsions as novel class of complexometric titration reagents." Chem. Commun. 50, no. 84 (2014): 12659–61. http://dx.doi.org/10.1039/c4cc05754f.

Full text
APA, Harvard, Vancouver, ISO, and other styles
11

Hudson, Robert J. M., Eden L. Rue, and Kenneth W. Bruland. "Modeling Complexometric Titrations of Natural Water Samples." Environmental Science & Technology 37, no. 8 (2003): 1553–62. http://dx.doi.org/10.1021/es025751a.

Full text
APA, Harvard, Vancouver, ISO, and other styles
12

FERNANDEZ-MAESTRE, Roberto, and Alonso J. MARRUGO-GONZÁLEZ. "5-ACETYL-8-HYDROXYQUINOLINE AND 5-FORMYL-8- HYDROXYQUINOLINE: CHELATING AGENTS FOR COMPLEXOMETRIC TITRATIONS." Periódico Tchê Química 16, no. 31 (2019): 765–77. http://dx.doi.org/10.52571/ptq.v16.n31.2019.776_periodico31_pgs_765_777.pdf.

Full text
Abstract:
Metal–organic ligand complexes are essential to many technological developments from protein supramolecular assemblies to solvent extraction, complexometric titrations, and environmental remediation. We studied the chelating and acid-base properties in ethanol of two derivatives of 8-hydroxyquinoline (Q), 5-acetyl-8-hydroxyquinoline (A) and 5-formyl-8-hydroxyquinoline (F), of which applications as chelators are unknown. The ligands acidity followed the order F (pKa1 2.9; pKa2 9.5)> A (pKa1 4.8; pKa2 9.6)> Q (pKa1 5.3; pKa2 10.0) due to inductive effects of electronegative groups, formyl
APA, Harvard, Vancouver, ISO, and other styles
13

Wolfbeis, O. "Fibre-optic titrations-IV Direct complexometric titration of aluminium(III) with DCTA." Talanta 33, no. 11 (1986): 867–70. http://dx.doi.org/10.1016/0039-9140(86)80214-4.

Full text
APA, Harvard, Vancouver, ISO, and other styles
14

Jo, K. "Continuous on-line feedback based flow titrations. Complexometric titrations of calcium and magnesium." Talanta 60, no. 1 (2003): 131–37. http://dx.doi.org/10.1016/s0039-9140(03)00114-0.

Full text
APA, Harvard, Vancouver, ISO, and other styles
15

Mallick, Abhijit. "Study of Estimation of Hardness of Water Using pH-Meter." International Research Journal of Pure and Applied Chemistry 25, no. 6 (2024): 78–86. https://doi.org/10.9734/irjpac/2024/v25i6886.

Full text
Abstract:
The hardness of water is one of the important parameters of water quality. The complexometric titration method is a prevalent technique to estimate concentrations of and ions individually, which are primarily responsible for the hardness of water. However, the method needs two external indicators to mark the end points of titrations. Furthermore, accuracy of the method is sacrificed due to inevitable parallax errors during marking of the endpoint of titration. This present work reports that during titration of a hard water sample with a complexing agent (here, solution), changes continuously.
APA, Harvard, Vancouver, ISO, and other styles
16

Jarujamrus, Purim, Nutthaporn Malahom, Sodsai Puchum, et al. "Complexometric and argentometric titrations using thread-based analytical devices." Talanta 183 (June 2018): 228–36. http://dx.doi.org/10.1016/j.talanta.2018.02.058.

Full text
APA, Harvard, Vancouver, ISO, and other styles
17

Abramović, B. F., and F. F. Gaál. "Complexometric catalytic titrations using the indicator reaction periodate-triethanolamine." Microchemical Journal 32, no. 2 (1985): 226–36. http://dx.doi.org/10.1016/0026-265x(85)90082-7.

Full text
APA, Harvard, Vancouver, ISO, and other styles
18

COSTA, Luiz Henrique Medeiros da, Francisco José Santos LIMA, and Ademir Oliveira da SILVA. "SYNTHESIS, COMPLEXOMETRY, THERMAL ANALYSIS AND MOLAR CONDUCTANCE OF LANTHANUM CHLORIDE, NEODYMIUM AND ERBIUM HYDRATED." Periódico Tchê Química 10, no. 19 (2013): 38–45. http://dx.doi.org/10.52571/ptq.v10.n19.2013.38_periodico19_pgs_38_45.pdf.

Full text
Abstract:
The lanthanum, neodymium and erbium chlorides were prepared from your respective starting oxides in aqueous suspension with slow addition of hydrochloric acid and later placed in desiccator. The compositions were characterized through of the complexometric titrations with EDTA, thermogravimetry (TG) and molar conductance. The TG curves were accomplished in synthetic air and we verified your thermal stabilities, and the process of thermal decomposition. The results obtained by the titration and for TG they made possible to establish the stoichiometry of the compounds that came as: LaCl3.7H2O, N
APA, Harvard, Vancouver, ISO, and other styles
19

Antonietta Baldo, M., Salvatore Daniele, Carlo Bragato, and Gian A. Mazzocchin. "Amperometric end-point detection of complexometric titrations with platinum microelectrodes." Analyst 124, no. 7 (1999): 1059–63. http://dx.doi.org/10.1039/a903144h.

Full text
APA, Harvard, Vancouver, ISO, and other styles
20

Bult, A., H. A. Dingjan, S. M. Dreijer-van der Glas, and W. P. Van Bennekom. "Generalized theory for two- phase ion- pair and complexometric titrations." Pharmaceutisch Weekblad 7, no. 6 (1985): 260–66. http://dx.doi.org/10.1007/bf01959199.

Full text
APA, Harvard, Vancouver, ISO, and other styles
21

Bult, A., H. A. Dingjan, S. M. Dreijer-van der Glas, and W. P. Van Bennekom. "Generalized theory for two-phase ion-pair and complexometric titrations." Pharmaceutisch Weekblad 7, no. 6 (1985): 267–72. http://dx.doi.org/10.1007/bf01959200.

Full text
APA, Harvard, Vancouver, ISO, and other styles
22

Benjamin Uchenna Modozie, Nkechi Helen Okoye, Innocent Oghale Ajawobu, et al. "Use of Ipomoea involucrata B. flower as metallochromic indicator for complexometric titrations." GSC Biological and Pharmaceutical Sciences 25, no. 1 (2023): 095–100. http://dx.doi.org/10.30574/gscbps.2023.25.1.0408.

Full text
Abstract:
The present work highlights the use of Ipomoea involucrate B. flower extract as a complexometric indicator in complex formation between the EDTA and the following metal solutions (Cu2,+ Ba2,+ Hg2+, Fe3+, and Bi3+). Ipomoea involucrate is a species of the Ipomoea genus, belonging to the family Convolvulaceae. This natural indicator was extracted in 2M HCl at 100 0C for 30-40 minutes, cooled and the extract filtered and extracted with ethyl acetate and the pigment extracted with amyl alcohol which was separated and concentrated over a water bath. The flower extract was screened for its use as an
APA, Harvard, Vancouver, ISO, and other styles
23

Ceretti, Helena, Enrique A. Hughes, and Anita Zalts. "The Softening of Hard Water and Complexometric Titrations. An Undergraduate Experiment." Journal of Chemical Education 76, no. 10 (1999): 1420. http://dx.doi.org/10.1021/ed076p1420.

Full text
APA, Harvard, Vancouver, ISO, and other styles
24

Zhai, Jingying, Xiaojiang Xie, and Eric Bakker. "Ion-Selective Optode Nanospheres as Heterogeneous Indicator Reagents in Complexometric Titrations." Analytical Chemistry 87, no. 5 (2015): 2827–31. http://dx.doi.org/10.1021/ac504213q.

Full text
APA, Harvard, Vancouver, ISO, and other styles
25

Benjamin, Uchenna Modozie, Helen Okoye Nkechi, Oghale Ajawobu Innocent, et al. "Use of Ipomoea involucrata B. flower as metallochromic indicator for complexometric titrations." GSC Biological and Pharmaceutical Sciences 25, no. 1 (2023): 095–100. https://doi.org/10.5281/zenodo.10575014.

Full text
Abstract:
The present work highlights the use of&nbsp;<em>Ipomoea involucrate B.&nbsp;</em>flower extract as a complexometric indicator in complex formation between the EDTA and the following metal solutions (Cu<sup>2</sup>,<sup>+</sup>&nbsp;Ba<sup>2</sup>,<sup>+&nbsp;</sup>Hg<sup>2+</sup>, Fe<sup>3+</sup>, and Bi<sup>3+</sup>).&nbsp;<em>Ipomoea involucrate&nbsp;</em>is a species of the&nbsp;<em>Ipomoea</em>&nbsp;genus, belonging to the family Convolvulaceae. This natural indicator was extracted in 2M HCl at 100&nbsp;<sup>0</sup>C for 30-40 minutes, cooled and the extract filtered and extracted with eth
APA, Harvard, Vancouver, ISO, and other styles
26

Maccà, Carlo. "Linear plots for complexometric potentiometric titrations of mixtures of two metal ions." Analyst 115, no. 5 (1990): 631–36. http://dx.doi.org/10.1039/an9901500631.

Full text
APA, Harvard, Vancouver, ISO, and other styles
27

Zhai, Jingying, Xiaojiang Xie, and Eric Bakker. "Solvatochromic Dyes as pH-Independent Indicators for Ionophore Nanosphere-Based Complexometric Titrations." Analytical Chemistry 87, no. 24 (2015): 12318–23. http://dx.doi.org/10.1021/acs.analchem.5b03663.

Full text
APA, Harvard, Vancouver, ISO, and other styles
28

Roe, James A., and Joan Selverstone Valentine. "Complexometric titrations of protein-bound metal ions: A method for determining binding constants." Analytical Biochemistry 186, no. 1 (1990): 31–40. http://dx.doi.org/10.1016/0003-2697(90)90568-t.

Full text
APA, Harvard, Vancouver, ISO, and other styles
29

Yappert, M. Cecilia, and Donald B. DuPre. "Complexometric Titrations: Competition of Complexing Agents in the Determination of Water Hardness with EDTA." Journal of Chemical Education 74, no. 12 (1997): 1422. http://dx.doi.org/10.1021/ed074p1422.

Full text
APA, Harvard, Vancouver, ISO, and other styles
30

Smith, Garon C., and Md Mainul Hossain. "Visualization of Metal Ion Buffering via Three-Dimensional Topographic Surfaces (Topos) of Complexometric Titrations." Journal of Chemical Education 94, no. 12 (2017): 1911–17. http://dx.doi.org/10.1021/acs.jchemed.7b00411.

Full text
APA, Harvard, Vancouver, ISO, and other styles
31

Bhardwaj, Nikita, Harshi Jaiswal, and Jaya Maitra. "Exploring Gelatin Films for Environmental Applications: Challenges and Opportunities." Asian Journal of Applied Science and Technology 08, no. 04 (2024): 166–82. https://doi.org/10.38177/ajast.2024.8415.

Full text
Abstract:
In this study, gelatin films were prepared by dissolving gelatin in distilled water with mechanical stirring, followed by casting the solution into films. The biodegradability of these films was confirmed through soil burial tests, and their rapid dissolution in water was evident, with a measured water solubility of 29±1.6%. The structural integrity and thermal stability of the films were characterized using UV and FTIR. The films exhibited significant UV-visible light absorbance, with a peak at 300 nm within the 280 to 480 nm range. FTIR spectra revealed the characteristic amide peaks of gela
APA, Harvard, Vancouver, ISO, and other styles
32

Almeida Amancio, Nathan, Poliana Coste E Colpa, Cíntia Moda Salatino Guardabaxo, Carla Beatriz Silva, and Leandro Gustavo Da Silva. "Removal of eriochrome black T from aqueous solution using coffee husk as bioadsorbent." Revista Agrogeoambiental 16, unico (2024): e20241892. http://dx.doi.org/10.18406/2316-1817v16nunico20241892.

Full text
Abstract:
The eriochrome black T dye belongs to the azo dye class and is often used as an indicator in complexometric titrations and as a fiber dye in industrial processes. It constitutes a direct threat to human health and the environment due to its toxic and carcinogenic nature. Separating this dye from wastewater is essential before its release into water bodies. In this work, the adsorption capacity of eriochrome black T in aqueous solution conferred on the chemically modified or unmodified coffee husk fibers was evaluated. Adsorption experiments were performed in triplicate and batch. The results o
APA, Harvard, Vancouver, ISO, and other styles
33

Risani Rusnel, Azizah, Dinda Putri Karim, Rahmida Marlini, and Siska Maharani. "Determination of CaCO3 Content in Egg Shell." Journal of Global Research Education 2, no. 2 (2025): 63–69. https://doi.org/10.62194/4y5hr711.

Full text
Abstract:
The complexometry titration investigation has been conducting to ascertain the CaCO3 concentration of Egg. The complex substance EDTA will hold the calcium, and the point will be signaled by a change in the metallochromic indicator's color. Standardization EDTA : Pipette 25 mL of MgSO4.7H2O solution, 10 mL of buffer solution pH 10, a little amount of EBT indicator, and aqua DM into the titration flask. When you titrate with EDTA solution, the solution turns blue. Data processing has revealed that eggshell contains 0,025 grams of calcium and that the calcium content is 14,1%. Theoretically, egg
APA, Harvard, Vancouver, ISO, and other styles
34

Michela SALVATORE, Maria, and Francesco SALVATORE. "Understanding Complexometric Titrations of Metal Cations with Aminopolycarboxylic Acids (EDTA and Analogs) within the frame of the Notion of Reactions between Groups of Chemical Species." World Journal of Chemical Education 3, no. 1 (2015): 5–21. http://dx.doi.org/10.12691/wjce-3-1-2.

Full text
APA, Harvard, Vancouver, ISO, and other styles
35

Schnitzler, Egon, Márcio Lazzarotto, Marco Aurelio da Silva Carvalho-Filho, and Massao Ionashiro. "Thermoanalytical study of the complexes of 4-dimethylaminocynnamylidenepyruvate with manganese (II), cobalt (II), nickel (II), copper (II), zinc (II) and lead (II), in the solid state." Ecletica Quimica 27, no. 1 (2002): 41–50. http://dx.doi.org/10.26850/1678-4618eqj.v27.1.2002.p41-50.

Full text
Abstract:
Solid state compounds M-4-DMCP, where 4-DMCP is 4-dimethylaminocinnamylidenepyruvate and M represents Mn (II), Co (II), Ni (II), Cu (II), Zn (II) and Pb (II) were prepared. These compounds were studied by thermoanalitycal techniques: thermogravimetry (TG), derivative thermogravimetry (DTG), differential scanning calorimetry (DSC), X-ray diffraction powder patterns and complexometric titration with EDTA. From the results obtained by the complexometric titration with EDTA, TG, DTG and DSC curves, was possible to establish the hydration degree, stoichiometry and thermal stability of the prepared
APA, Harvard, Vancouver, ISO, and other styles
36

Pereira, Claudia Mara, Cristhiane Anete Neiverth, Shizuo Maeda, Marcela Guiotoku, and Luziane Franciscon. "Complexometric titration with potenciometric indicator to determination of calcium and magnesium in soil extracts¹." Revista Brasileira de Ciência do Solo 35, no. 4 (2011): 1331–36. http://dx.doi.org/10.1590/s0100-06832011000400027.

Full text
Abstract:
This study proposes a method of direct and simultaneous determination of the amount of Ca2+ and Mg2+ present in soil extracts using a Calcium Ion-Selective Electrode and by Complexometric Titration (ISE-CT). The results were compared to those obtained by conventional analytical techniques of Complexometric Titration (CT) and Flame Atomic Absorption Spectrometry (FAAS). There were no significant differences in the determination of Ca2+ and Mg2+ in comparison with CT and FAAS, at a 95 % confidence level. Additionally, results of this method were more precise and accurate than of the Interlaborat
APA, Harvard, Vancouver, ISO, and other styles
37

Simiyon, G. Gnanamani, and Ansha Elizabeth Mammen. "A Green Approach for Complexometric Titration*." Resonance 27, no. 4 (2022): 681–86. http://dx.doi.org/10.1007/s12045-022-1358-6.

Full text
APA, Harvard, Vancouver, ISO, and other styles
38

Guinon, Jose L. "Graphical evaluation of complexometric titration curves." Talanta 32, no. 4 (1985): 265–72. http://dx.doi.org/10.1016/0039-9140(85)80078-3.

Full text
APA, Harvard, Vancouver, ISO, and other styles
39

Nur Khadijah Anasyah, Nurfadillah Nurfadillah, Dian Fadillah, et al. "Penetapan Kadar Kalsium Laktat dengan Menggunakan Metode Titrasi Kompleksometri." OBAT: Jurnal Riset Ilmu Farmasi dan Kesehatan 3, no. 1 (2025): 269–75. https://doi.org/10.61132/obat.v3i1.1033.

Full text
Abstract:
This research aims to determine calcium lactate levels using the complexometric titration method, which involves the formation of a complex between metal ions and ligands, specifically using EDTA (Ethylenediaminetetraacetate) as a titrant. The sample was dissolved in distilled water, the murexide indicator was added, and titrated with complexon III solution until the color changed from orange to violet as a marker for the end point of the titration. Data analysis shows that the percentage of calcium lactate levels in replication (1) is 93.32%, replication (2) 101.60%, replication (3) 95.93%, r
APA, Harvard, Vancouver, ISO, and other styles
40

J, K. Mondal, Basak S., S. Mukherjee S., and Kundu Dipali. "Chelatometric titration of iron, zinc and aluminium involving masking and demasking with acetylacetone." Journal of Indian Chemical Society Vol. 79, Jan 2002 (2002): 92–94. https://doi.org/10.5281/zenodo.5843026.

Full text
Abstract:
Analytical Chemistry Division, Central Glass &amp; Ceramic Research Institute, Kolkata-700 032, India <em>E-mail : </em>dipali_kundu@hotmail.com <em>Manuscript received 31 May 2000, revised 16 March 2001, accepted 12 May 2001</em> A stepwise complexometric method with EDTA has been developed for the determination of iron, zinc and aluminium in a single aliquot solution involving direct titration of iron(m)-acetylacetonate at pH 3.0 using acetylacetone as an auto-indicator. Zinc is deter&shy;mined in the same solution by direct titration with EDTA raising pH to 5.3 using xylenol orange as indic
APA, Harvard, Vancouver, ISO, and other styles
41

Li, Shixian, Kunpeng Zhou, Xinyin Xu, Yangyang Zhao, and Jing Li. "Application of Herbal Medicine in Cu2+ Removal from Water and Comparison of its Detection Methods." Scholars Journal of Agriculture and Veterinary Sciences 10, no. 05 (2023): 37–42. http://dx.doi.org/10.36347/sjavs.2023.v10i05.002.

Full text
Abstract:
In order to utilize discarded herbal medicine to treat heavy metal pollution in water, various herbal medicines were selected to explore their abilities of metal ions removal. In this experiment, copper ion was used as targeted heavy metal ion and two different treatments of several herbal medicines were compared on the effect of the copper ion removal ability. At the evaluating stage, four metal ion detection methods were employed and analyzed in this herbal medicine Cu2+ removal application. The results showed that directly soaking herbal medicine in the copper aqueous solution was more effe
APA, Harvard, Vancouver, ISO, and other styles
42

Tianlin, Wang, Liu Fengling, and Feng Liming. "Theoretical analysis of one-one complexometric titration curves." Journal of Chemical Education 70, no. 10 (1993): 796. http://dx.doi.org/10.1021/ed070p796.

Full text
APA, Harvard, Vancouver, ISO, and other styles
43

Cassedanne, Jeannine Odette, and Hamílcar Freire de Carvalho. "Dosagem de silício em silico-fosfatos naturais." Anuário do Instituto de Geociências 13 (December 1, 1990): 39–42. http://dx.doi.org/10.11137/1990_0_39-42.

Full text
Abstract:
This study describes a silicon volumetric titration in minerals silico-phosphates. Silicon is precipited as quinolin silico-molibdate and molybdenum is titsted by complexometric-accumulation method. In the range of 0,5 to 2,5 mg of silicon, a precision of about 0,5% is reached with a good reproducibility. A previous elimination of phosphates ions is necessary.
APA, Harvard, Vancouver, ISO, and other styles
44

Taufik, Moh, Seveline Seveline, and Emilia Ratih Saputri. "Validasi Metode Analisis Kadar Kalsium pada Susu Segar secara Titrasi Kompleksometri." Agritech 38, no. 2 (2018): 187. http://dx.doi.org/10.22146/agritech.25459.

Full text
Abstract:
Analysis of calcium content in fresh milk generally uses Atomic Absorption Spectroscopy (AAS). Alternatively, it could be analyzed using complexometric titration. The study aimed to validate the method of calcium content analysis in fresh milk by complexometric titration. The results showed that the linearity test using calcium standard solution at a working range of 4-24 mg/100 mL had R2 of 0.9983, while the limit of detection and limit of quantification were 0.47 mg/100 mL and 1.57 mg/100 mL, respectively. The accuracy by spiking method at the spiking concentration of 60 mg/100 mL sample was
APA, Harvard, Vancouver, ISO, and other styles
45

Suarez, Maria L., Alfredo Calvo, and Luis E. Leon. "Complexometric Titration of Metals Using a Lead Selective Electrode." Analytical Letters 19, no. 11-12 (1986): 1219–28. http://dx.doi.org/10.1080/00032718608066296.

Full text
APA, Harvard, Vancouver, ISO, and other styles
46

Yi, Chen, Dongjie Huang, and Miklós Gratzl. "Complexometric Determination of Metal Ions by Microscopic Diffusional Titration." Analytical Chemistry 68, no. 9 (1996): 1580–84. http://dx.doi.org/10.1021/ac950636m.

Full text
APA, Harvard, Vancouver, ISO, and other styles
47

Novick, S. G. "Complexometric Titration of Zinc: An Analytical Chemistry Laboratory Experiment." Journal of Chemical Education 74, no. 12 (1997): 1463. http://dx.doi.org/10.1021/ed074p1463.

Full text
APA, Harvard, Vancouver, ISO, and other styles
48

Evstratova, K. I., T. Yu Ivanovskaya, and I. V. Kucheryavaya. "Complexometric-conductometric titration analysis of drugs and food additives." Pharmaceutical Chemistry Journal 33, no. 12 (1999): 675–79. http://dx.doi.org/10.1007/bf02974947.

Full text
APA, Harvard, Vancouver, ISO, and other styles
49

Herlina, Herlina, and Muhammad Razali. "The redox titration of Fe (II) ions with K2Cr2O7 using a potentiometry method the effect of EDTA and SCN- ligands." Pharmaciana 14, no. 3 (2024): 276–88. https://doi.org/10.12928/pharmaciana.v14i3.28638.

Full text
Abstract:
Complexometric titration is often used for determining the metal content, either through direct titration or back titration. This study aimed to investigate redox titration between Mohr salt solutions and potassium dichromate in an acidic atmosphere in the pH range 2. The results showed that the reaction proceeded effectively at pH 2, with Mohr's salt solution acting as titrant. Furthermore, experiments were conducted to compare the effectiveness of EDTA ligands and SCN- ligands in improving the sharpness of the Fe2+/ Cr2O72- redox titration curve at pH 2. Results show that EDTA ligands are mo
APA, Harvard, Vancouver, ISO, and other styles
50

Zulfisa Zulfisa and Rini Lestari. "Penetapan Kadar Kalsium Pada Daun Krokot (Portulaca Oleracea L.) Secara Kompleksometri." Journal Pharma Saintika 6, no. 1 (2022): 01–07. http://dx.doi.org/10.51225/jps.v6i1.15.

Full text
Abstract:
Research on the determination of calcium levels in purslane (Portulaca oleracea L.) leaves has been carried out using the indirect complexometric titration method. Fresh purslane leaves were extracted using 3N HC1, dissolved calcium was added to an excess of 0.05 M NazEDTA solution and the excess Na EDTA was titrated with 0.05 M MgSO4 solution using an EBT indicator. Obtained calcium levels in fresh purslane leaves of 0.1503% w/w.
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!