Dissertations / Theses on the topic 'Concrete electrical resistivity'
Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles
Consult the top 28 dissertations / theses for your research on the topic 'Concrete electrical resistivity.'
Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.
You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.
Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.
Malakooti, Amir. "Investigation of Concrete Electrical Resistivity As a Performance Based Test." DigitalCommons@USU, 2017. https://digitalcommons.usu.edu/etd/6858.
Full textXiao, Lianzhen. "Interpretation of hydration process of concrete based on electrical resistivity measurement /." View abstract or full-text, 2007. http://library.ust.hk/cgi/db/thesis.pl?CIVL%202007%20XIAO.
Full textWang, Boyu. "Durability evaluation of cement-based repair materials used for corrosion-damaged steel-reinforced concrete structures." Thesis, 1st International Conference on New Horizons in Green Civil Engineering (NHICE), 2018. https://dspace.library.uvic.ca//handle/1828/9330.
Full textGraduate
2020-04-30
Barrus, Natasha Christine. "Sensitivity of Resistivity Measurements on Concrete Bridge Decks to Operator-Controlled and Concrete Material Variables." BYU ScholarsArchive, 2012. https://scholarsarchive.byu.edu/etd/3203.
Full textBarton, Jeffrey David. "Vertical Electrical Impedance Measurements on Concrete Bridge Decks Using a Large-Area Electrode." BYU ScholarsArchive, 2018. https://scholarsarchive.byu.edu/etd/6981.
Full textDeda, Hugo. "The Influence of the Binder Type & Aggregate Nature on the Electrical Resistivity and Compressive Strength of Conventional Concrete." Thesis, Université d'Ottawa / University of Ottawa, 2020. http://hdl.handle.net/10393/41463.
Full textRosa, Dalton Wegner da. "RESISTIVIDADE ELÉTRICA DE CONCRETOS COM DIFERENTES TEORES DE ESCÓRIA DE ALTO FORNO E ATIVADOR QUIMICO." Universidade Federal de Santa Maria, 2005. http://repositorio.ufsm.br/handle/1/7942.
Full textA manutenção da integridade das armaduras nas estruturas de concreto é uma conseqüência da proteção física e química do concreto sobre o aço. A destruição da camada passivadora antecede o processo corrosivo. Uma vez iniciada a corrosão, a velocidade desta dependerá da resistividade elétrica existente entre o ânodo e o cátodo e também pela quantia de oxigênio presentes junto ao cátodo. A resistividade do concreto caracteriza-se por ser uma propriedade ligada tanto a características físicas como químicas do mesmo. Neste trabalho objetivou-se estudar o comportamento da adição de escória de alto forno na resistividade elétrica aparente dos concretos, assim como correlacionar com a resistência à compressão e as alterações químicas na fase aquosa bem como na estrutura dos poros. Foram realizadas investigações em misturas com relação a/agl 0,35, 0,50 e 0,65 com teores de substituição em massa de 0, 50 e 70% de EAF. Investigou-se também os efeitos produzidos pela incorporação de 4% de sulfato de sódio (Na2SO4) em misturas contendo 50% de EAF. A resistividade elétrica do concreto foi determinada utilizando o método dos quatro eletrodos (método de Wenner adaptado para uso em concreto). Foram também realizados ensaios de resistência à compressão axial, porosimetria, concentração de íons da fase aquosa e determinada a condutividade elétrica específica da solução dos poros. Constatou-se aumento na resistividade elétrica do concreto com o aumento no grau de hidratação e do teor de escória. Este comportamento está relacionado a menor condutividade elétrica específica da solução dos poros e ao refinamento dos poros comprovado pela boa correlação entre esses dois fatores. A mistura binária composta por 50% de escória (50E) apresentou a melhor relação custo/benefício para os níveis de resistência de 30MPa e 50MPa aos 28 dias e também para o nível de resistência de 50MPa aos 91 dias.
Santor, Marcelo Silva. "INFLUÊNCIA DE MATERIAIS DE PROTEÇÃO SUPERCIAL NA RESISTIVIDADE ELÉTRICA E ABSORÇÃO CAPILAR DO CONCRETO." Universidade Federal de Santa Maria, 2011. http://repositorio.ufsm.br/handle/1/7762.
Full textThe durability of concrete structures is the result of protective action of concrete over the rebar. When the passivation of steel ceases to exist the structure becomes vulnerable to the phenomenon of corrosion, which spread after start is largely controlled by the electrical resistivity of concrete. Another important factor in the durability of concrete structures is the absorption, which is one of the properties governing the transport of ions inside the concrete. This study aimed to evaluate the electrical resistivity and capillary absorption of concrete that have undergone surface treatment: a monolithic polymeric mortar applied in a layer of 4mm, and a pore blocker with a single coat and a pore blocker with a double coat. The concrete surface subjected to treatment were made with three types of cement,CP IV-32, CP II-F 32 and CP V and levels of compressive strength of 15MPa, 20MPa and 25MPa. The electrical resistivity was measured by the method of four electrodes and capillary absorption by the method NBR 9779. Treatment with the pore blocker with a double coat was more effective in reducing capillary absorption than a pore blocker with a single coat for the three types of cement, but the best results were obtained using the polymer mortar. In this work the pozzolanic effect present on cement CP IV became more clear in the result of electrical resistivity for all treatment studied. The different behavior of the electrical resistivity of concrete with cement CP IV in relation to others, CPII F and CP V, is justified by changes in the microstructure of the paste, pore refinement and composition of pore solution. In addition to this, when compared to concrete made with CP V, the lower relations/binder of CP IV to obtain the compressive strengh levels investigated, fck = 15 Mpa , 20Mpa and 25Mpa. Even the reference concrete without surface treatment showed values of resistivity well above the actual reference compounds with CP II-F and CP V and also subjected to surface treatment.
A durabilidade das estruturas de concreto armado é resultado da ação protetora do concreto sobre a armadura. Quando a passivação do aço deixa de existir a estrutura torna-se vulnerável ao fenômeno da corrosão, cuja propagação, após iniciada é essencialmente controlada pela resistividade elétrica do concreto. Outro fator importante na durabilidade das estruturas do concreto é a absorção capilar, a qual é uma das propriedades que regem o transporte de íons no interior do concreto. O presente estudo teve por objetivo avaliar a resistividade elétrica e a absorção capilar em concretos que foram submetidos a tratamento superficial: uma argamassa polimérica monocomponente aplicada em camada de 4mm, e um produto obturador dos poros aplicado em uma e duas demãos. Os concretos submetidos ao tratamento superficial foram produzidos com três tipos de cimento, CP IV 32, CP II F 32 e CP V, e para os níveis de resistência à compressão de 15MPa, 20MPa e 25MPa. A resistividade elétrica foi medida pelo método dos quatros eletrodos e a absorção capilar segundo o método NBR 9779. O tratamento com o produto obturador dos poros em dupla demão mostrou-se mais efetivo na redução da absorção capilar do que o tratamento com uma demão para os três tipos de cimento, contudo, os melhores resultados foram obtidos com o uso da argamassa polimérica. Neste trabalho o efeito pozolânico presente no cimento CP IV ficou claro nos resultados de resistividade elétrica para todos os tratamentos estudados. Este comportamento diferenciado do CP IV em relação aos demais, CP II F e CP V, se justifica pelas alterações na microestrutura da pasta, refinamento dos poros e composição da solução dos poros. Acresce a isto, quando comparado aos concretos produzidos com CP V, as menores relações a/agl do CP IV para obtenção dos níveis de resistência à compressão investigados. Mesmo o concreto de referência sem tratamento superficial apresentou valores de resistividade elétrica muito superiores aos concretos de referência compostos com CP II F e CP V e também submetidos a tratamento superficial.
Braun, Carlos Eduardo. "Determinação instantânea da relação água-cimento e da resistência à compressão do concreto no estado fresco através do método da resistividade elétrica." Universidade do Vale do Rio dos Sinos, 2015. http://www.repositorio.jesuita.org.br/handle/UNISINOS/5002.
Full textMade available in DSpace on 2016-02-15T14:12:54Z (GMT). No. of bitstreams: 1 Carlos Eduardo Braun_.pdf: 3816402 bytes, checksum: 868ecc968577b70b35d2cfde265248ec (MD5) Previous issue date: 2015-04-07
CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
PROSUP - Programa de Suporte à Pós-Gradução de Instituições de Ensino Particulares
Durante a execução de elementos de concreto no canteiro de obras, procedimentos de controle de qualidade do concreto são adotados com o objetivo de verificar se o material atende às características de projeto. Esta verificação também visa evitar falhas durante as etapas subsequentes da construção, que podem levar até à inviabilização do empreendimento. Estudos sobre métodos que têm como objetivo estimar a relação água/cimento (a/c) do concreto no estado fresco vêm recebendo maior atenção nos últimos tempos, devido à importância deste parâmetro sobre a resistência e durabilidade das estruturas de concreto, e por não existirem métodos práticos e precisos disponíveis até o momento, que permitam a sua determinação após a realização da mistura. Estudos sobre o método da resistividade elétrica apontam para uma forte correlação entre os valores de resistividade e a relação água/cimento do concreto no estado fresco, possibilitando a utilização do método como uma interessante alternativa para determinação da relação a/c. O presente estudo tem como objetivo apresentar uma análise do método da resistividade elétrica, aplicado à estimativa de valores de relação água/cimento de concretos no estado fresco, confeccionados com cimentos nacionais, além da estimativa de valores de resistência à compressão axial do concreto no estado endurecido. Foram realizados ensaios com concretos dosados a partir do método IPT/EPUSP para seis cimentos nacionais (CPV-ARI, CPIV-32, CPIII-40, CPII-Z-32, CPII-F-32 e CPII-E-40), variando-se a relação a/c (0,35, 0,45, 0,55 e 0,65), utilizando uma sonda aprimorada para realização dos testes, a qual foi desenvolvida neste estudo com base num protótipo já desenvolvido anteriormente. Os resultados obtidos apontam para uma forte correlação existente entre a resistividade elétrica do concreto no estado fresco e a relação a/c, com valores médios das estimativas para relação a/c dentro do intervalo de ±0,02, com relação aos valores efetivos das misturas testadas. A margem de erro média para as estimativas de relação a/c, considerando-se todos os cimentos testados, ficou no intervalo entre 2,25% e 9,38%. Foram obtidos coeficientes de determinação na ordem de 85,7% a 95,2% para as estimativas de resistência à compressão, mostrando que é possível determinar tanto a relação a/c quanto a resistência à compressão do concreto através do método da resistividade elétrica, quando o material encontra-se ainda no estado fresco.
During construction of concrete elements in the building site, quality control proceedings are adopted in order to verify if the concrete reaches its design specifications, which also avoids failures during the subsequent stages of the construction. Test methods used for the determination of the water-cement (w/c) ratio have received increased attention, due to the importance of this ratio for the concrete resistance and durability, and also because there isn’t any practical and sufficiently precise method available at the moment, which could be used for determining water-cement ration after mixing. Studies about the electrical resistivity method have shown a strong relationship between the measured resistivity values and water-cement ratio, for the fresh concrete, making this method an interesting alternative for determining w/c ratio. This study presents an analysis of the electrical resistivity method, applied to determine the water-cement ratio of several fresh concrete mixtures made with different types of Brazilian cements, in addition to estimates of compressive strength values of the hardened concretes. Concrete mixtures were made out of six cement types (CPV-ARI, CPIV-32, CPIII-40, CPII-Z-32, CPII-F-32 and CPII-E-40), dosed by the IPT/EPUSP method, and four water-cement ratios (0.35, 0.45, 0.55 and 0.65). Tests were performed using an improved probe, developed in this study, based in one prototype developed previously. Results shown a strong relationship between the electrical resistivity of fresh concrete and its water-cement ratio, with average estimated values within ±0,02 of the actual water-cement ratio values for the mixtures tested. The average error for the w/c ratio estimated values, considering all of the cements tested, was between 2,25% and 9,38%. The compressive strength estimates reached coefficients of determination between 85,7% and 95,2%, showing that it is possible to estimate both w/c ratio and compressive strength of concrete while still in the fresh state with the electrical resistivity method presented here.
Chabi, Parham. "Comparative Investigation of Detection Techniques for Chloride-induced Corrosion of Loaded Reinforced Concrete Slabs." Thesis, Université d'Ottawa / University of Ottawa, 2012. http://hdl.handle.net/10393/23170.
Full textHoppe, Tiago Fernandes. "RESISTIVIDADE ELÉTRICA DE CONCRETOS CONTENDO DIFERENTES TEORES DE CINZA DE CASCA DE ARROZ." Universidade Federal de Santa Maria, 2005. http://repositorio.ufsm.br/handle/1/7671.
Full textA durabilidade das estruturas de concreto armado é resultado da ação protetora do concreto sobre o aço. Quando a passivação do aço deixa de existir, a estrutura torna-se vulnerável ao fenômeno da corrosão, cuja propagação, após iniciada, é essencialmente controlada pela resistividade elétrica do concreto entre o ânodo e o cátodo e pela disponibilidade de oxigênio no cátodo. A resistividade elétrica do concreto é uma propriedade extremamente sensível às características físicas e químicas do mesmo. O presente trabalho buscou investigar a influência do teor de cinza de casca de arroz (CCA) na resistividade elétrica do concreto, bem como correlacionar os resultados obtidos com a resistência à compressão axial e alterações na composição da solução aquosa e estrutura dos poros. Foram investigadas misturas com relações água/aglomerante (a/ag) 0,35 , 0,50 e 0,65 com teores de substituição em massa de 10%, 20% e 30% de CCA. Para comparar os resultados, misturas com 50% de escória de alto forno, 35% de cinza volante e uma mistura de referência com 100% de cimento foram simultaneamente investigadas. A resistividade elétrica foi determinada utilizando o método dos quatro eletrodos (método de Wenner, adaptado para uso em concreto). Paralelamente, foram realizados ensaios de resistência à compressão axial, composição, pH e condutividade elétrica específica da solução aquosa dos poros e porosimetria por intrusão de mercúrio. Verificou-se que a idade, a relação a/ag e as adições minerais mostraram uma influência expressiva na resistividade elétrica do concreto, em virtude principalmente das alterações na estrutura dos poros e na quantidade e composição da solução dos mesmos. Os resultados mostraram um crescimento exponencial na resistividade do concreto com o aumento do teor de CCA. Tal fato foi confirmado pelo maior refinamento dos poros e menor condutividade específica da solução dos mesmos, mostrando haver uma ótima correlação entre estes fatores. Assim, os melhores resultados na resistividade elétrica foram obtidos com o teor de 30% de CCA. A melhor relação CUSTO/BENEFÍCIO, para 65MPa de resistência à compressão e 30kΩ.cm de resistividade elétrica, foi obtida com 10% de CCA e, para 65MPa e 60kΩ.cm, os melhores resultados foram atingidos com 20% desta adição.
Lübeck, André. "RESISTIVIDADE ELÉTRICA DE CONCRETOS DE CIMENTO PORTLAND BRANCO E ELEVADOS TEORES DE ESCÓRIA DE ALTO FORNO." Universidade Federal de Santa Maria, 2008. http://repositorio.ufsm.br/handle/1/7691.
Full textA resistividade elétrica é uma importante propriedade do concreto por permitir avaliar a facilidade de acesso de agentes agressivos antes de instalado o processo corrosivo e estimar a velocidade do mesmo depois de instalado, sendo conjuntamente com a disponibilidade de oxigênio um dos parâmetros determinantes para a velocidade da corrosão. Este trabalho teve como objetivo avaliar o desempenho de concretos de cimento Portland branco com elevados teores de escória de alto forno e ativação química quanto à resistividade elétrica aparente. Foram avaliadas além da resistividade outras grandezas como resistência à compressão, porosidade e condutividade específica da solução dos poros. Foram investigadas quatro misturas, uma de referência contendo apenas cimento, uma segunda com teor de substituição de cimento por escória de 50%, outra com teor de substituição de 70% e uma última contendo 50% de escória e ativador alcalino, Na2SO4, em um teor de 4%. As relações água/aglomerante foram fixadas em 0,30, 0,42 e 0,55 para todas as misturas. A medida da resistividade elétrica foi realizada através do método dos quatro eletrodos (Wenner). A resistividade elétrica se mostrou dependente da idade, relação a/ag e teor de escória, principalmente, em função das alterações que estas proporcionam na estrutura de poros da pasta. A resistividade cresceu proporcionalmente ao aumento do teor de escória. O aumento do teor de escória resultou também em menor condutividade da solução aquosa e refinamento da estrutura de poros da pasta. Por outro lado, a resistência à compressão diminuiu com o crescimento do teor de escória. Os maiores valores de resistividade elétrica foram apresentados pela mistura contendo 70% de escória. Esta mistura se mostrou a de melhor relação custo/benefício quando se fixaram valores de resistência à compressão de 35 e 55 MPa, aos 28 dias, e 60 MPa, aos 91 dias.
Taillet, Elodie. "Caractérisation des discontinuités dans des ouvrages massifs en béton par la diagraphie électrique de résistivité." Thèse, Université de Sherbrooke, 2014. http://savoirs.usherbrooke.ca/handle/11143/128.
Full textMello, Anna Beatriz Alves de [UNESP]. "Argamassas autoadensáveis utilizando cinzas de casca de arroz como finos: comparação com o caso de argamassas vibradas." Universidade Estadual Paulista (UNESP), 2016. http://hdl.handle.net/11449/144199.
Full textApproved for entry into archive by Felipe Augusto Arakaki (arakaki@reitoria.unesp.br) on 2016-09-27T17:47:58Z (GMT) No. of bitstreams: 1 mello_aba_me_ilha.pdf: 4452313 bytes, checksum: 5912cb6b4a6d246206f745348ff2b0e1 (MD5)
Made available in DSpace on 2016-09-27T17:47:58Z (GMT). No. of bitstreams: 1 mello_aba_me_ilha.pdf: 4452313 bytes, checksum: 5912cb6b4a6d246206f745348ff2b0e1 (MD5) Previous issue date: 2016-08-01
O trabalho apresenta um estudo exploratório sobre o uso de cinzas de casca de arroz como finos em argamassas autoadensáveis. Para tanto foram realizadas composições de argamassas vibradas e autoadensáveis variando-se os parâmetros tais como a relação água/cimento, superplastificante/cimento, e volume de agregado miúdo/volume de argamassa, mantendo-se constante a relação finos/cimento, e as relações água/materiais secos, bastante próximas. Foram realizados ensaios no estado fresco e no estado endurecido. Para o estado fresco foram realizados de modo a poder nortear as composições, a saber: ensaio Flow- table para os casos de argamassas vibradas e de espalhamento Slump-flow para os casos de argamassas autoadensáveis, ensaio Slump-test para os casos de argamassas vibradas e de escoamento confinado V-funnel para os casos de argamassas autoadensáveis, e avaliação da massa específica aparente. No estado endurecido foram realizados os ensaios de resistência à compressão simples e diametral, e os de absorção d’água. Os resultados foram então comparados uns com os outros ou analisados dentro do seu contexto. Encontraram-se valores que puderam corroborar para as vantagens do uso das cinzas de casca de arroz nas argamassas autoadensáveis, sobretudo nos resultados relativos aos valores das resistências mecânicas alcançadas e dos níveis de absorção d’água. Observou-se também aparente rigidez para os casos das argamassas autoadensáveis. Observou-se que as argamassas autoadensáveis podem alcançar um comportamento diferenciado na diminuição dos valores de absorção d’água com o tempo, de modo a se antecipar estas reduções dentro de seus níveis máximos permitidos.
The paper presents an exploratory study on the use of rice husk ash as fine in self-compacting mortars. Therefore, we conducted compositions vibrated and self-compacting mortars varying parameters such as the water/cement superplasticizer/cement ratio and the volume of fine aggregate/volume of mortar, keeping constant the fines/cement ratio, and the relationship water/dry materials very close. Assays were performed in fresh and hardened state. For fresh state were conducted in order to guide the compositions as follows: Flow-test table for cases of vibrated mortar Slump-flow and spread in cases of self-compacting mortar, Slump-test assay for the cases of mortars vibrated and V-funnel flow confined to cases self-compacting mortars, and evaluation of the bulk density. In the hardened state were performed strength tests to simple and diametrical compression, and the water absorption. The results were then compared with each other or analyzed in context. They met values that might corroborate the advantages of the use of rice husk ash in self-compacting mortars, particularly in the results for the values of mechanical strength and achieved the levels of water absorption. There was also apparent rigidity for cases of self-compacting mortars. It was observed that the mortar self-compacting can achieve a differentiated behavior in decreasing the water absorption values over time in order to anticipate these reductions within their maximum permitted levels.
Mello, Anna Beatriz Alves de. "Argamassas autoadensáveis utilizando cinzas de casca de arroz como finos : comparação com o caso de argamassas vibradas /." Ilha Solteira, 2016. http://hdl.handle.net/11449/144199.
Full textResumo: O trabalho apresenta um estudo exploratório sobre o uso de cinzas de casca de arroz como finos em argamassas autoadensáveis. Para tanto foram realizadas composições de argamassas vibradas e autoadensáveis variando-se os parâmetros tais como a relação água/cimento, superplastificante/cimento, e volume de agregado miúdo/volume de argamassa, mantendo-se constante a relação finos/cimento, e as relações água/materiais secos, bastante próximas. Foram realizados ensaios no estado fresco e no estado endurecido. Para o estado fresco foram realizados de modo a poder nortear as composições, a saber: ensaio Flow- table para os casos de argamassas vibradas e de espalhamento Slump-flow para os casos de argamassas autoadensáveis, ensaio Slump-test para os casos de argamassas vibradas e de escoamento confinado V-funnel para os casos de argamassas autoadensáveis, e avaliação da massa específica aparente. No estado endurecido foram realizados os ensaios de resistência à compressão simples e diametral, e os de absorção d’água. Os resultados foram então comparados uns com os outros ou analisados dentro do seu contexto. Encontraram-se valores que puderam corroborar para as vantagens do uso das cinzas de casca de arroz nas argamassas autoadensáveis, sobretudo nos resultados relativos aos valores das resistências mecânicas alcançadas e dos níveis de absorção d’água. Observou-se também aparente rigidez para os casos das argamassas autoadensáveis. Observou-se que as argamassas autoadensáveis podem al... (Resumo completo, clicar acesso eletrônico abaixo)
Abstract: The paper presents an exploratory study on the use of rice husk ash as fine in self-compacting mortars. Therefore, we conducted compositions vibrated and self-compacting mortars varying parameters such as the water/cement superplasticizer/cement ratio and the volume of fine aggregate/volume of mortar, keeping constant the fines/cement ratio, and the relationship water/dry materials very close. Assays were performed in fresh and hardened state. For fresh state were conducted in order to guide the compositions as follows: Flow-test table for cases of vibrated mortar Slump-flow and spread in cases of self-compacting mortar, Slump-test assay for the cases of mortars vibrated and V-funnel flow confined to cases self-compacting mortars, and evaluation of the bulk density. In the hardened state were performed strength tests to simple and diametrical compression, and the water absorption. The results were then compared with each other or analyzed in context. They met values that might corroborate the advantages of the use of rice husk ash in self-compacting mortars, particularly in the results for the values of mechanical strength and achieved the levels of water absorption. There was also apparent rigidity for cases of self-compacting mortars. It was observed that the mortar self-compacting can achieve a differentiated behavior in decreasing the water absorption values over time in order to anticipate these reductions within their maximum permitted levels.
Mestre
Mostardeiro, Neto Carlos Zinn. "ABSORÇÃO CAPILAR E RESISTIVIDADE ELÉTRICA DE CONCRETOS COMPOSTOS COM CINZA DE CASCA DE ARROZ DE DIFERENTES TEORES DE CARBONO GRAFÍTICO." Universidade Federal de Santa Maria, 2011. http://repositorio.ufsm.br/handle/1/7779.
Full textHá, cada vez mais, uma busca de alternativas para reduzir o impacto ambiental na produção de insumos, como o cimento, que é altamente poluente. Adições minerais têm sido investigadas como substituições parciais ao cimento no concreto, pois, além de propiciar o aproveitamento de resíduos industriais, os quais muitas vezes não possuem destinação específica e são degradantes do ponto de vista ambiental, podem oferecer melhora nas características de durabilidade do material, conforme verificado em estudos anteriores. No Brasil, que é um grande produtor de arroz, são geradas anualmente milhões de toneladas da casca deste cereal, sendo parte dessa utilizada para produção de energia, em usinas termoelétricas. A cinza da casca de arroz, resultante da queima da casca, tem sido fonte de pesquisas visando a sua utilização como substituição parcial ao cimento do concreto. Ainda são poucos os estudos que fazem um comparativo da influência da viabilidade da utilização da cinza de casca de arroz com diferentes teores de carbono grafítico (cinza clara e escura), obtidas por queima controlada, frente a características de durabilidade em concretos. Neste trabalho, misturas contendo diferentes teores de CCA clara e escura foram investigadas quanto ao desempenho em concreto estrutural, através dos ensaios de absorção de água por capilaridade, segundo a NBR 9779:1995 e resistividade elétrica aparente, conforme o método dos quatro eletrodos (Wenner). Adicionalmente, realizou-se o ensaio de resistência à compressão axial, de acordo com a NBR 5739:2007. Para isso, foram testadas oito misturas aglomerantes, investigadas nas relações a/ag 0,35, 0,50 e 0,65: uma composta por 100% de cimento Portland, REF, três com substituição de cimento por CCA clara, em teores de 10%, 20% e 30%, denominadas 10 CCAC, 20 CCAC e 30 CCAC, respectivamente, outras três com os mesmos teores de troca de cimento por CCA escura, identificadas por 10 CCAE, 20 CCAE e 30 CCAE, respectivamente, e uma mistura com 10% de sílica ativa, 10 SA, para comparação de resultados. O aumento no prazo de cura e no teor de substituição de cimento por CCA resultou em melhor desempenho para as propriedades investigadas. Em igualdade de relação a/ag, no geral, os valores de resistência à compressão foram semelhantes, indiferentemente do teor de carbono grafítico da CCA. As misturas compostas com CCAE apresentaram melhor desempenho quanto à absorção capilar, embora superadas pela mistura com SA. Com relação à resistividade elétrica, a mistura composta com 30% de CCAC apresentou melhor desempenho em todas as idades de ensaio.
Bezerra, Sergio Ricardo Campos. "Avaliação de sistemas de aterramento considerando a utilização de condutores e hastes envolvidos em concreto." Universidade de São Paulo, 2011. http://www.teses.usp.br/teses/disponiveis/86/86131/tde-16082011-163415/.
Full textThe electrical grounding plays an essential role in a system of electric power distribution, and must follow, among many requirements, those ones established as step voltage values and touch voltage values. However, in those places where the soil has high resistivity values, some difficulties arise and may not always be overcomed in order to follow the requirements set forth in technical standards and specifications. In this context, the aim of this study is to evaluate the use of electrical conductors and rods encased in concrete inside grounding systems, in order to reduce the ground resistance values. Initially it was observed a conventional configuration of grounding grid that is used by an electric utility, and studies were made in order to verify the influence of the number of rods and the distance between them in the values of grounding resistance. There are also been taken into consideration the changes in the grounding grid dimensions and the use of deep rods and, right after, the results of other configurations are analyzed. In order to verify the effectiveness of the use of concrete, several computer simulations were performed considering the grounding system that used conductors and rods encased in concrete. Several situations were investigated, and it was possible to conclude that the use of concrete results in lower values of ground resistance compared to conventional grounding grid. This result, in a certain way, matches with the expectations, but it should be emphasized the contribution of the study which enables, through theoretical calculations, the analysis of the grounding grid behavior with the use of concrete. The literature shows few theoretical results and presents only some researches on this issue in which ones only measurements made in the field are considered.
David, Marie. "Optimisation de la dispersion des fibres pendant le cycle de malaxage des bétons industriels." Thesis, Paris Est, 2014. http://www.theses.fr/2014PEST1157/document.
Full textFibers are added to the concrete to give it news properties. The homogeneity of these characteristics is assured by a constant presence of fiber as the whole material. The dispersion of one species within another is governed by convection and/or diffusion mechanisms. Concerning objects having the size of steel fiber, these two phenomena are caused by the shearing applied to the material, an unknown and difficult to measure datum in the case of concrete mixer. To begin, a method allowing to estimate the mixer's shearing is suggested. This method is based on the measurement of the medium diameter of cement aggregates produced in the mixer. The link between the medium diameter and the mean shearing is established. In a second time, a mean to measure fiber dispersion from electrical resistivity measurements during the concrete mixing is presented. Then, in a third time, fiber dispersion are measured during mixing. The link between necessary time to obtain an homogeneous distribution and the mixer's shearing ability is established
Alhajj, Marie Antoinette. "Inversion conjointe de mesures non destructives pour l'évaluation des gradients de degré de saturation dans le béton d'enrobage des structures." Thesis, Ecole centrale de Nantes, 2020. http://www.theses.fr/2020ECDN0017.
Full textNon-destructive assessment methods providing access to the measurement of electrical resistivity and dielectric permittivity are very sensitive to the degree of saturation of concrete. When inverted and calibrated independently, these measurements provide profiles of saturation degree gradients as a function of depth. In this thesis, we develop a joint inversion approach for resistivity and permittivity measurements to improve the reliability and accuracy of the estimated saturation degree profiles. We model the measurements on a concrete slab in 3D by the finite element method, the concrete being considered as a homogeneous medium with respect to aggregates but having a saturation profile with depth, represented by a continuous model taking the form of a Weibull distribution with four parameters. For the inversion of measurements to estimate the profile of S, we have developed a non-linear least-squares algorithm of the Levenberg-Marquardt type. Taking into account the uncertainties associated with each set of measurements is an integral part of the method developed in order to refine its reliability, which also makes it possible to propagate these uncertainties over the estimated parameters. Two experimental campaigns, one of drying, the other of imbibition, on concrete slabs, are organized to test the algorithm of joint inversion. Significant progress has been made with the estimation of profiles by the new joint inversion approach. These profiles, also compared to other independent methods, appear to be more stable and more consistent with the evolution due to the drying and the imbibition of concrete than those estimated by separate inversion of the observables
Pimenta, Camila Madeiros Alcantara. "Avalia??o da influ?ncia da resistividade el?trica do solo e de tipos de envelopamento no sistema de aterramento el?trico de subesta??es." Pontif?cia Universidade Cat?lica de Campinas, 2017. http://tede.bibliotecadigital.puc-campinas.edu.br:8080/jspui/handle/tede/1011.
Full textMade available in DSpace on 2018-02-19T16:48:56Z (GMT). No. of bitstreams: 1 CAMILA MADEIROS ALCANTARA PIMENTA.pdf: 4765494 bytes, checksum: dac59f354329911b1dfcb8422a61af1b (MD5) Previous issue date: 2017-12-15
Electrical grounding is part of the Atmospheric Discharge Protection System (ADPS), whose functions are to provide a path for the circulation of electric current in the ground and to enable the detection of a possible fault between the energized conductors and the earth. For grounding to be efficient, some characteristics must be taken into account, such as soil type and resistivity. In this sense, measurements of resistivity and soil stratification are important for a correct sizing of the grounding system. Soils with high water concentration (low resistivity) are better current conductors than dry soils, for example. Soils with high resistivity can cause a return current. Thus, some decisions aimed at strengthening the grounding system should be taken when there are soils with inadequate grounding characteristics. Therefore, this work aims to evaluate the influence of soil electrical resistivity and enveloping types using concrete types in the substation electrical grounding system through software simulations, taking into account soil resistivity characteristics. In the analysis of types of envelopment, it was possible to observe that the concretes with greater amount of water in their composition have a lower electrical resistivity. The use of concrete enveloping is feasible for soils with high resistivity, as in the case of the land located in the city of Campinas, and it was possible to verify that for soils with low resistivity its use may be impractical since other options such as inclusion of more cables and installation of the rods in the layers with less resistivity are sufficient and more economical.
O aterramento el?trico faz parte do Sistema de Prote??o Contra Descargas Atmosf?ricas (SPDA), cujas fun??es s?o fornecer um caminho para a circula??o de corrente el?trica na terra, escoamento para a terra de cargas induzidas nas carca?as dos equipamentos el?tricos e, em conjunto com os dispositivos diferenciais-residuais, possibilitar a detec??o de uma poss?vel falha entre os condutores energizados e a terra. Para que o aterramento seja eficiente, algumas caracter?sticas devem ser levadas em considera??o, tais como o tipo e a resistividade do solo. Neste sentido, medi??es da resistividade e a estratifica??o do solo s?o importantes para um dimensionamento correto do sistema de aterramento. Solos com alta concentra??o de ?gua (baixa resistividade) s?o melhores condutores de corrente do que um solo seco, por exemplo. Solos com alta resistividade podem ocasionar uma corrente de retorno. Assim, algumas decis?es visando o refor?o do sistema de aterramento devem ser tomadas quando se tem solos com caracter?sticas inadequadas ao aterramento. Portanto, esse trabalho teve como objetivo avaliar a influ?ncia da resistividade el?trica do solo e de tipos de envelopamento utilizando tipos de concreto no sistema de aterramento el?trico de subesta??es atrav?s de simula??es em software, levando em conta as caracter?sticas de resistividade do solo. Nas an?lises de tipos de envelopamento, foi poss?vel observar que os concretos com maior quantidade de ?gua em sua composi??o possuem uma resistividade el?trica mais baixa. A utiliza??o do envelopamento de concreto ? vi?vel para solos com alta resistividade, como ? o caso do terreno localizado na cidade de Campinas, e foi poss?vel verificar que para solos com resistividade baixa sua utiliza??o pode ser invi?vel j? que outras op??es como inclus?o de mais cabos e instala??o das hastes nas camadas com menor resistividade s?o suficientes e mais econ?micas.
Dia, Abdou. "Monitoring des câbles de structures du génie civil par combinaison de techniques vibratoires et émission acoustique." Thesis, Ecole centrale de Nantes, 2020. http://www.theses.fr/2020ECDN0046.
Full textNon-destructive assessment methods providing access to the measurement of electrical resistivity and dielectric permittivity are very sensitive to the degree of saturation of concrete. When inverted and calibrated independently, these measurements provide profiles of saturation degree gradients as a function of depth. In this thesis, we develop a joint inversion approach for resistivity and permittivity measurements to improve the reliability and accuracy of the estimated saturation degree profiles. We model the measurements on a concrete slab in 3D by the finite element method, the concrete being considered as a homogeneous medium with respect to aggregates but having a saturation profile with depth, represented by a continuous model taking the form of a Weibull distribution with four parameters. For the inversion of measurements to estimate the profile of S, we have developed a non-linear least-squares algorithm of the Levenberg-Marquardt type. Taking into account the uncertainties associated with each set of measurements is an integral part of the method developed in order to refine its reliability, which also makes it possible to propagate these uncertainties over the estimated parameters. Two experimental campaigns, one of drying, the other of imbibition, on concrete slabs, are organized to test the algorithm of joint inversion. Significant progress has been made with the estimation of profiles by the new joint inversion approach. These profiles, also compared to other independent methods, appear to be more stable and more consistent with the evolution due to the drying and the imbibition of concrete than those estimated by separate inversion of the observables
Badr, Joanna. "Conception et validation d'un capteur noyé de résistivité électrique en vue du suivi des profils de teneur en eau dans les bétons." Thesis, Toulouse 3, 2019. http://www.theses.fr/2019TOU30153.
Full textElectrical resistivity is a parameter sensitive to various properties of concrete, including water content, which is one of the key parameters governing concrete long-term durability. In this study, the problem of monitoring the concrete water content profile throughout the concrete structure thickness is addressed using a method based on DC- electrical resistivity measurements. This is of great importance for concrete repository structures used for radioactive waste and for applications requiring centimetric resolution of the water content profile over a thick structure. The aim of this thesis is to design and produce a novel multi-electrode embedded sensor for monitoring the resistivity profile over depth in order to estimate the water content profile. The study focuses on the design of two sensors based on printed circuit board (PCB), which brings several advantages, including geometric accuracy and mitigation of wiring issues, in order to increase the durability of the sensors and to reduce invasiveness. Different measurement configurations are analyzed and compared. In addition, numerical modeling of the sensor response and its ability to assess an imposed resistivity profile is carried out, as well as the influence of the steel reinforcement on the response of the sensors placed in the center of the reinforcement mesh. Experimental validations using saline solutions of known conductivity and concrete specimens subjected to drying are studied. The results demonstrate the capability of the sensor to evaluate resistivity profiles in concrete with centimetric resolution. To enlarge our scale and approach real structures, the sensors are embedded in two 30 cm thick concrete slabs instrumented by other sensors to compare the results. Calibration of the measurements is carried out to determine the water content profile taking the temperature into account. The saturation degree profiles obtained with the innovative sensors developed in this thesis are compared to the profiles obtained from reference measurements (thermohygrometric sensors and gammadensimetry) and give consistent results with the evolution of the concrete due to drying
Taillet, Elodie. "Caractérisation des discontinuités dans des ouvrages massifs en béton par la diagraphie électrique de résistivité." Phd thesis, Université Sciences et Technologies - Bordeaux I, 2013. http://tel.archives-ouvertes.fr/tel-00982066.
Full textKienNguyen, Van, and 阮凡欽. "Effects of Coarse Aggregates to the Electrical Resistivity of Concrete." Thesis, 2012. http://ndltd.ncl.edu.tw/handle/15021887552931993176.
Full text國立成功大學
土木工程學系碩博士班
100
In this study, the influences of coarse aggregate to the electrical resistivities of concrete were investigated. Specifically, types and sizes of the aggregates were targeted as the studied parameters. Commercially available granites and marbles with various sizes of 4.75, 9.5, 12.5, and 19mm were used in the concrete mixtures, and the resistivities at the age of 28 days were investigated. Polarization induced resistivity growth during the electrical measurement were considered and experimentally nullified, such that the real bulk resistivities of concrete specimens can be obtained for comparison. Concrete specimens were made by cement mortars and several degrees (amounts) of coarse aggregates; with a fixed size of coarse aggregates used in a single specimen. Cement mortars were mixed with the water/cement ratio of 0.4, and the cement/sand ratio was held constantly at 1:1. The microstructures of certain specimen samples were obtained by Scanning Electron Microscopy so as to estimate the porosity of cement pastes, which is the primary conductive portion of cementitious materials. This was done to validate the resistivity observation. The results show that the electrical resistivities of concrete made with crushed granites were quite close to those that made with crushed marbles. Moreover, the particle size of aggregates seems to have no significant influences to concrete resistivities while it is to concrete strengths. As a partial study of nondestructive testing technologies to the performance estimations of concrete, further studies were required and we have drew a few comments.
Yan, Chui Quing, and 顏垂慶. "Effect of Pozzolans on the Chloride Diffusion Cofficients and Electrical Resistivity of Concrete." Thesis, 1998. http://ndltd.ncl.edu.tw/handle/08738193162577247410.
Full text國立海洋大學
河海工程學系
86
In this thesis,the effect of fly ash on the chloride diffusion coefficient and electrical resistivity of concrete is studied. The two-cell accelerated ion migration test has been adopted for measuring the chloride diffusion coefficient of concrete,and the four-eletrode resistivity measurement is used for evlaluating the surface and cross-sectional resistance of concrete. Test variables include various water/binder rations and various cement weight replacement percentanges by fly ash.It is found that the chloride diffusion coefficient apparantly increase as the water/binder ratio increase,and under the same water/binder ratio condition it decrease as the cement replacement by fly ash increase. Also the resistivity decreases as the water/binder ratio increase,and under the same water/ binder ratio condition it increase as the cement replacement by fly ash increase. There exists a unifield relation between the chloride diffusion coefficient and resistivity. Due to the lack of aggregate effect,the surface resistance is not appropriate to be an index of the compacthess of concrete.
Lin, Cing-Jung, and 林慶鐘. "The study on the electrical resistivity of carbon fiber concrete under different loading conditions." Thesis, 2015. http://ndltd.ncl.edu.tw/handle/jv8nbt.
Full text國立臺北科技大學
土木工程系土木與防災碩士班
104
Concrete has been widely used in various fields of civil engineering in many decades, and the health monitoring of the concrete structures has become more important in recent years. The high-performance sensing materials continue to be adopted in the monitoring and sensing of civil engineering structures, such as the piezoelectric material and carbon fiber material, etc., the suitable materials for applying to the civil engineering should have the features of low cost, well durability and stability, and high sensitivity. Carbon fiber material is one of the sensing materials that can be applied to the monitoring and sensing of civil engineering structures. When the carbon fiber concrete specimen subjected to the applied loads, the stretch or squeeze of the carbon fiber itself will cause the change of resistivity of the specimen, therefore, this properties can be applied to measure the deformation of the concrete specimen by measuring the change of the resistivity. In this research, the main purpose is to discuss the influence of the loading rate and cycles of loading to the fractional change of resistivity of the carbon fiber concrete. The test results show that the change of resistivity decreased as the loading rate increased under the same loading, and the influence from the cycles of loading is not very obviously.
Shahroodi, Ahmad. "Development of Test Methods for Assessment of Concrete Durability for Use in Performance-based Specifications." Thesis, 2010. http://hdl.handle.net/1807/25796.
Full textAzarsa, Pejman. "Multi-scale investigation and resistivity-based durability modeling of EShC containing crystalline admixtures." Thesis, 2018. https://dspace.library.uvic.ca//handle/1828/10127.
Full textGraduate
2019-09-11