To see the other types of publications on this topic, follow the link: Constant current mode control.

Dissertations / Theses on the topic 'Constant current mode control'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 50 dissertations / theses for your research on the topic 'Constant current mode control.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.

1

Huang, Bin. "Modeling and design of digital current-mode constant on-time control." Thesis, Virginia Tech, 2008. http://hdl.handle.net/10919/31487.

Full text
Abstract:
This thesis presents the fundamental issues of the digital controlled DC/DC converter. A lot of challenges exist when you introduce the digital control technique into the control of the DC/DC converter, especially with regards to the voltage regulator module. One issue is the limit cycle oscillation problem caused by the quantization effect from the ADC and DPWM of the digital control chip. Another issue is the delay problem coming from the sample-hold effect. In this thesis, the modeling, analysis and design methodology for the constant frequency voltage-mode control is reviewed. A DPWM (D
APA, Harvard, Vancouver, ISO, and other styles
2

Bari, Syed Mustafa Khelat. "A Novel Inverse Charge Constant On-Time Control for High Performance Voltage Regulators." Diss., Virginia Tech, 2018. http://hdl.handle.net/10919/82510.

Full text
Abstract:
One of the fundamental characteristics of the microprocessor application is its property of dynamic load change. Although idle most of the time, it wakes up in nanoseconds to support sudden workload demands, which are becoming increasingly severe in today's multi-core processors with large core count. From the standpoint of its voltage regulator (VR) design, it must have very good efficiency at light loads, while also supporting a very fast transient response. Thus, the variable-frequency constant on-time current-mode (COTCM) control scheme is widely used in the VRs, as it can automatically re
APA, Harvard, Vancouver, ISO, and other styles
3

Chadha, Ankit. "Average Current-Mode Control." Wright State University / OhioLINK, 2015. http://rave.ohiolink.edu/etdc/view?acc_num=wright1453228923.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Tsai, Fu-Sheng. "Constant-frequency, clamped-mode resonant converters." Diss., Virginia Polytechnic Institute and State University, 1989. http://hdl.handle.net/10919/54800.

Full text
Abstract:
Two novel clamped-mode resonant converters are analyzed. These clamped-mode converters operate at a constant frequency while retaining many desired features of conventional resonant converters such as fast responses, zero-voltage turn-on or zero-current turn-off, and low EMI levels, etc. The converters are able to regulate the output from no load to full load and are particularly suitable for off-line, high-power applications. To provide insights to the operations and derive design guidelines for the clamped-mode resonant converters, a complete dc characterization of both the clamped-mode ser
APA, Harvard, Vancouver, ISO, and other styles
5

Chin, Yuan. "Constant-frequency parallel-resonant converter (clamped-mode)." Thesis, Virginia Polytechnic Institute and State University, 1986. http://hdl.handle.net/10919/104308.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Hallworth, Michael. "Digital peak current mode control of switched-mode power supplies." Thesis, University of Reading, 2013. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.602418.

Full text
Abstract:
Peak current mode control is a popular method of SMPS control due the inherent cycle-by- cycle current limiting, feed-forward control and current sharing ability it provides. However, the subharmonic oscillations which plague peak current mode control must be removed using slope compensation. Until the work presented in this thesis, there have been no true digital implementations of peak current mode control due to the difficulties associated with implementing a digital form of slope compensation. This thesis introduces a complete digital peak current mode converter which uses a novel method o
APA, Harvard, Vancouver, ISO, and other styles
7

Mai, Yuan Yen. "Current-mode DC-DC buck converter with current-voltage feedforward control /." View abstract or full-text, 2006. http://library.ust.hk/cgi/db/thesis.pl?ECED%202006%20MAI.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Tang, Wei. "Average current-mode control and charge control for PWM converters." Diss., This resource online, 1994. http://scholar.lib.vt.edu/theses/available/etd-03042009-041130/.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Peng, Hao. "Digital current mode control of DC-DC converters." Diss., Connect to online resource, 2006. http://gateway.proquest.com/openurl?url_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:dissertation&res_dat=xri:pqdiss&rft_dat=xri:pqdiss:3207767.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

He, Dake. "Microcontroller-based current-mode control for power converters." Auburn, Ala., 2005. http://repo.lib.auburn.edu/2005%20Fall/Dissertation/HE_DAKE_26.pdf.

Full text
APA, Harvard, Vancouver, ISO, and other styles
11

Li, Jian. "Current-Mode Control: Modeling and its Digital Application." Diss., Virginia Tech, 2009. http://hdl.handle.net/10919/27019.

Full text
Abstract:
Due to unique characteristics, current-mode control architectures with different implementation approaches have been widely used in power converter design to achieve current sharing, AVP control, and light-load efficiency improvement. Therefore, an accurate model for current-mode control is indispensable to system design due to the existence of subharmonic oscillations. The fundamental difference between current-mode control and voltage-mode control is the PWM modulation. The inductor current, one of state variables, is used in the modulator in current-mode control while an external ramp i
APA, Harvard, Vancouver, ISO, and other styles
12

Ridley, Raymond Bryan. "A new small-signal model for current-mode control." access full-text online access from Digital dissertation consortium, 1990. http://libweb.cityu.edu.hk/cgi-bin/er/db/ddcdiss.pl?9116643.

Full text
APA, Harvard, Vancouver, ISO, and other styles
13

Ridley, Raymond B. "A new small-signal model for current-mode control." Diss., This resource online, 1990. http://scholar.lib.vt.edu/theses/available/etd-07282008-135124/.

Full text
APA, Harvard, Vancouver, ISO, and other styles
14

Keller, Lisa A. "Current-mode control of a magnetic amplifier post regulator." Thesis, This resource online, 1991. http://scholar.lib.vt.edu/theses/available/etd-02132009-171329/.

Full text
APA, Harvard, Vancouver, ISO, and other styles
15

Yu, Feng. "Modeling of V2 Control with Composite Capacitors and Average Current Mode Control." Thesis, Virginia Tech, 2011. http://hdl.handle.net/10919/33458.

Full text
Abstract:
Various types of current mode control are being used in different applications. Model for current mode control is indispensable for proper system design. Since 1980s, modeling of current mode control has been a hot topic in power electronics field. In current mode control, sub-harmonic oscillation is a common issue, especially for constant frequency current mode control: like peak current mode control, valley current mode control, or average current mode control. Recently V2 control is becoming more and more popular due to its simple implementation ad super fast transient response. V2 control
APA, Harvard, Vancouver, ISO, and other styles
16

Fick, Pieter D. "Evaluation of the constant current angle controlled reluctance synchronous machine drive." Thesis, Stellenbosch : Stellenbosch University, 2002. http://hdl.handle.net/10019.1/52837.

Full text
Abstract:
Thesis (MScEng)--University of Stellenbosch, 2002.<br>ENGLISH ABSTRACT: This thesis describes. the design and evaluation of a constant current angle controller for a variable speed reluctance synchronous machine (RSM) drive, as an energy efficient high performance drive. An accurate model of the RSM, with the use of finite element analysis, is derived and implemented in simulation software. The current- and speed controllers are designed and evaluated using a complete simulation model of the whole drive. The controller is implemented on a TMS320F240 DSPbased digital controller, which wa
APA, Harvard, Vancouver, ISO, and other styles
17

Kotecha, Ramchandra M. "Analysis and Comparison of Popular Models for Current-Mode Control of Switch Mode Power Supplies." Wright State University / OhioLINK, 2011. http://rave.ohiolink.edu/etdc/view?acc_num=wright1300211710.

Full text
APA, Harvard, Vancouver, ISO, and other styles
18

Pal, Subarna. "Simulation of current mode control schemes for power factor correction circuits." Thesis, National Library of Canada = Bibliothèque nationale du Canada, 1998. http://www.collectionscanada.ca/obj/s4/f2/dsk2/tape17/PQDD_0008/MQ36162.pdf.

Full text
APA, Harvard, Vancouver, ISO, and other styles
19

Wan, Kai. "Advanced current-mode control techniques for DC-DC power electronic converters." Diss., Rolla, Mo. : Missouri University of Science and Technology, 2009. http://scholarsmine.mst.edu/thesis/pdf/Wan_09007dcc80642d38.pdf.

Full text
Abstract:
Thesis (Ph. D.)--Missouri University of Science and Technology, 2009.<br>Vita. The entire thesis text is included in file. Title from title screen of thesis/dissertation PDF file (viewed May 4, 2009) Includes bibliographical references.
APA, Harvard, Vancouver, ISO, and other styles
20

De, Kock Hugo Werner. "Dynamic control of the permanent magnet assisted reluctance synchronous machine with constant current angle." Thesis, Stellenbosch : University of Stellenbosch, 2006. http://hdl.handle.net/10019.1/2062.

Full text
Abstract:
Thesis (MScEng (Electrical and Electronic Engineering))--University of Stellenbosch, 2006.<br>This thesis is about the dynamic control of a permanent magnet assisted reluctance synchronous machine (PMA RSM). The PMA RSM in this thesis is a 110 kW traction machine and is ideal for the use in electrical rail vehicles. An application of the dynamic control of the PMA RSM in electrical rail vehicles is to reduce wheel slip. The mathematical model of the PMA RSM is derived and explained in physical terms. Two methods of current control for the PMA RSM are investigated, namely constant field cu
APA, Harvard, Vancouver, ISO, and other styles
21

Yan, Yingyi. "Unified Three-terminal Switch Model for Current Mode Controls." Thesis, Virginia Tech, 2010. http://hdl.handle.net/10919/35647.

Full text
Abstract:
Current-mode control architectures with different implementation approaches have been an indispensable technique in many applications, such as voltage regulator, power factor correction, battery charger and LED driver. Since the inductor current ramp, one of state variables influenced by the input voltage and the output voltage, is used in the modulator in current-mode control without any low pass filter, high order harmonics play important role in the feedback control. This is the reason for the difficulty in obtaining the small-signal model for current-mode control in the frequency domain. A
APA, Harvard, Vancouver, ISO, and other styles
22

Nicolae, DV, PJ Ehlers, and CG Richards. "An investigation on optimal current mode control for boost-type PWM rectifiers." Tshwane University of Technology, 2008. http://encore.tut.ac.za/iii/cpro/DigitalItemViewPage.external?sp=1001163.

Full text
Abstract:
Abstract-- Static power converters produce harmonics due to the nature of the conversion process. This paper will investigate the effect on the power factor of a sinusoidal and Fryze current reference on a PWM boost type rectifier. It has been shown in previous papers that a Fryze current ref is best. This paper will develop a mathematical model, based on the single sided Fourier expansion. Using this mathematical model it will be shown that even though a high harmonic content could be present in a Fryze controlled PWM boost type rectifier, the power factor has been optimally improved.
APA, Harvard, Vancouver, ISO, and other styles
23

Yan, Yingyi. "Equivalent Circuit Model for Current Mode Controls and Its Extensions." Diss., Virginia Tech, 2013. http://hdl.handle.net/10919/50485.

Full text
Abstract:
Current-mode control architectures have been an indispensable technique in many applications, such as Voltage Regulator, Point-of-load converters, power factor correction, battery charger and LED driver. Since the inductor current ramp is used in the modulator in current-mode control without any low pass filter, high order harmonics play important role in the feedback control. This is the reason for the difficulty in obtaining the small-signal model for current-mode control in the frequency domain. A continuous time domain model was recently proposed as a successful model for current-mode cont
APA, Harvard, Vancouver, ISO, and other styles
24

Saini, Dalvir K. "True-Average Current-Mode Control of DC-DC Power Converters: Analysis, Design, andCharacterization." Wright State University / OhioLINK, 2018. http://rave.ohiolink.edu/etdc/view?acc_num=wright1531776568809249.

Full text
APA, Harvard, Vancouver, ISO, and other styles
25

Holme, Peter R. "Digital control of high frequency PWM convertors." Thesis, Loughborough University, 1994. https://dspace.lboro.ac.uk/2134/7160.

Full text
Abstract:
The thesis begins with a review of presently available analogue and digital control schemes for high frequency PWM converters. Advantages and disadvantages of each scheme are identified, to determine which features would be desirable in a new digital control scheme. An extensive examination of peak and average current mode control is undertaken, using state-space/sampled data modelling, to gain more detailed information on the properties of current mode control. On the basis of this information, a new digital current mode control scheme is put forward. This uses samples of the inductor current
APA, Harvard, Vancouver, ISO, and other styles
26

Sen, Gokhan. "Voltage and Current Programmed Modes in Control of the Z-Source Converter." University of Akron / OhioLINK, 2008. http://rave.ohiolink.edu/etdc/view?acc_num=akron1226508637.

Full text
APA, Harvard, Vancouver, ISO, and other styles
27

Arbetter, Barry Steven. "DC-DC converter utilizing hysteretic current-mode control for low-voltage microprocessor systems with power management." Diss., Connect to online resource, 2006. http://gateway.proquest.com/openurl?url_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:dissertation&res_dat=xri:pqdiss&rft_dat=xri:pqdiss:3219222.

Full text
APA, Harvard, Vancouver, ISO, and other styles
28

Louganski, Konstantin. "Generalized Average-Current-Mode Control of Single-Phase AC-DC Boost Converters with Power Factor Correction." Diss., Virginia Tech, 2007. http://hdl.handle.net/10919/27331.

Full text
Abstract:
The dissertation presents a generalized average-current-mode control technique (GACMC), which is an extension of the average-current-mode control (ACMC) for single-phase ac-dc boost converters with power factor correction (PFC). Traditional ACMC is generalized in a sense that it offers improved performance in the form of significant reduction of the current control loop bandwidth requirement for a given line frequency in unidirectional and bidirectional boost PFC converters, and additional functionality in the form of reactive power control capability in bidirectional converters. These feature
APA, Harvard, Vancouver, ISO, and other styles
29

Deng, Songquan. "CONTROL AND TOPOLOGY IMPROVEMENTS IN HALF-BRIDGE DC-DC CONVERTERS." Doctoral diss., University of Central Florida, 2005. http://digital.library.ucf.edu/cdm/ref/collection/ETD/id/2749.

Full text
Abstract:
Efficiency and transient response are two key requirements for DC-DC converters. Topology and control are two key topics in this dissertation. A variety of techniques for DC-DC converter performance improvement are presented in this work. Focusing on the efficiency issue, a variety of clamping techniques including both active and passive methods are presented after the ringing issues in DC-DC converters are investigated. By presenting the clamping techniques, a big variety of energy management concepts are introduced. The active bridge-capacitor tank clamping and FET-diode-capacitor tank clamp
APA, Harvard, Vancouver, ISO, and other styles
30

Haryani, Nidhi. "Zero Voltage Switching (ZVS) Turn-on Triangular Current Mode (TCM) Control for AC/DC and DC/AC Converters." Diss., Virginia Tech, 2020. http://hdl.handle.net/10919/96397.

Full text
Abstract:
One of the greatest technological challenges of the world today is reducing the size and weight of the existing products to make them portable. Specifically, in electric vehicles such as electric cars, UAVs and aero planes, the size of battery chargers and inverters needs to be reduced so as to make space for more parts in these vehicles. Electromagnetic Interference (EMI) filters take up a more than 80 % of these power converters, the size of these filters can be reduced by pushing the switching frequency higher. High frequency operation (> 300 kHz) leads to a size in reduction of EMI filters
APA, Harvard, Vancouver, ISO, and other styles
31

Rahim, Nasrudin Abd. "Closed-loop control of a current-mode AC/DC buck converter in 4 quadrant P-Q operation." Thesis, Heriot-Watt University, 1995. http://hdl.handle.net/10399/1342.

Full text
APA, Harvard, Vancouver, ISO, and other styles
32

Ding, Guanyu 1987. "Digital current mode control for multiple input converters." Thesis, 2012. http://hdl.handle.net/2152/ETD-UT-2012-08-6274.

Full text
Abstract:
In this thesis, the possibility of applying digital current mode control on multiple-input (MI) converters is studied. As for MI topologies having a central energy transfer inductor, the predictive constant on-time current-mode control can greatly reduce both the design and digital realization efforts needed. By doing digital constant on-time current-mode control, the control of MI buck and MI buck-boost converters can be simplified into an equivalent-single-input converter control problem. The small signal models of digital constant on-time controlled single-input (SI), MI buck and SI, MI buc
APA, Harvard, Vancouver, ISO, and other styles
33

Hsu, Yu-Chien, and 徐郁茜. "Modeling of the Control Behavior of Current-Mode Constant On-Time Boost Converters." Thesis, 2015. http://ndltd.ncl.edu.tw/handle/66457742386029772719.

Full text
Abstract:
碩士<br>國立臺灣大學<br>電機工程學研究所<br>103<br>The constant on-time (COT) controller for DC converters has received much attention recently for the reason of its unique feature of high conversion efficiency under both the heavy-load and light-load conditions. However, most of the published papers on this subject have been focused on the buck converters. In this thesis, a boost converter using the current-mode COT controller is considered. It finds applications in hand-held mobile devices. The focus of the efforts is to establish a small-signal control model for the current-mode constant on-time (CMC
APA, Harvard, Vancouver, ISO, and other styles
34

Chen, Yung-Jen, and 陳永任. "Modeling of a Constant On-Time Current-Mode Control Scheme with Offset-Correction and Adaptive Voltage Positioning Functions for Voltage Regulators." Thesis, 2012. http://ndltd.ncl.edu.tw/handle/68013320994299716908.

Full text
Abstract:
碩士<br>國立臺灣大學<br>電機工程學研究所<br>100<br>Voltage regulators have been widely used in many computer applications for powering the central processing units (CPU). Converter efficiency has always been a design priority but most emphasis had been placed on the efficiency under the heavy-load conditions until recent years. Considering the fact that most of the DC converters are operating under light-load or standby conditions most of the time, the total energy loss is significant especially considering the number of computers used today. To meet the challenges described above, constant on-time (COT) cont
APA, Harvard, Vancouver, ISO, and other styles
35

陳文資. "Study of Constant Current Control for Resistance Spot Welding." Thesis, 2005. http://ndltd.ncl.edu.tw/handle/34841815662875086947.

Full text
Abstract:
碩士<br>國立彰化師範大學<br>電機工程學系<br>93<br>ABSTRACT The goal of this thesis is to investigate the power control technology of resistance spot welding machine. Currently, there are four kinds of power control method in the industrial spot welding, which are AC-type power control, DC-type power control, condenser-type power control and inverter-type power control. After comparing and analyzing the properties of the various resistance spot welding machines, the inverter-type resistance spot welding machine has steady output current, high dynamic performance and excellent welding quality. Therefore, its
APA, Harvard, Vancouver, ISO, and other styles
36

Chen, Yan-Mou, and 陳彥謀. "Stability Investigations of a Current-mode Constant Off-time LED Driver Circuit." Thesis, 2013. http://ndltd.ncl.edu.tw/handle/97468368393444741144.

Full text
Abstract:
碩士<br>國立臺灣大學<br>電機工程學研究所<br>101<br>Light-emitting-diode (LED) applications for illumination have enjoyed a tremendous growth in the last five years. There are a variety of LED driver circuits reported in recent years. Depending upon the application requirements, the driver circuit scheme may vary, but the general feature of a driver circuits is to control the LED current level for light level or dimming control. In this thesis, the focus is on the LED backlight applications for display units in which an accurate light-level control is important. This is a control scheme first reported in a com
APA, Harvard, Vancouver, ISO, and other styles
37

Nien, Chin-Fu, and 粘儆夫. "A Novel Adaptive Quasi-Constant On-Time Current-Mode Controlled Buck Converter." Thesis, 2017. http://ndltd.ncl.edu.tw/handle/vdwkwg.

Full text
Abstract:
博士<br>國立臺灣大學<br>電機工程學研究所<br>105<br>In recent years, there have been a variety of constant on-time control (COT) schemes for DC power converter applications. This class of converters features high efficiency for both the heavy load and the light load conditions. However, its step-load transient response is, by-and-large, poor unless special circuitry is used to speed up the response. In this dissertation, an adaptive quasi-constant on time current mode (AQCOTCM) control scheme is described. Using this control scheme, a converter can achieve faster step-load response and operating frequency ind
APA, Harvard, Vancouver, ISO, and other styles
38

Hsiang-YiChu and 朱湘儀. "Dual Buck Inverter with Constant Frequency Variable Hysteresis Current Control." Thesis, 2014. http://ndltd.ncl.edu.tw/handle/90045155481958795728.

Full text
Abstract:
碩士<br>國立成功大學<br>電機工程學系<br>102<br>The purpose of this thesis is to implement a dual buck inverter for tide power transfer system. Because the change of front-end tide power transfer system output AC voltage could be varying and low. By realized the first stage of boost converter to rectify and boost the voltage, then convert power to the second stage of dual buck inverter. The thesis presents a new control strategy of constant frequency with variable hysteresis width. It can design the filter and choose power components easily when using the new type control. Compare to conventional hysteresis
APA, Harvard, Vancouver, ISO, and other styles
39

Su, Chien-Chung, and 蘇建中. "Constant Stator Current Control for Three-Phase Induction Motor Drive with Fixed Exciting Current." Thesis, 2013. http://ndltd.ncl.edu.tw/handle/jn6z6s.

Full text
Abstract:
碩士<br>國立虎尾科技大學<br>電機工程研究所<br>101<br>In this thesis, a constant stator current control for three-phase induction motor drive with fixed exciting current is proposed. The motor drive consists of three power switches, three power diodes and two dc power sources. Due to three-switch inverter and the special three-phase current waveforms, three windings of induction motor open alternately in the operation. Therefore, one of winding of induction motor is used to detect air gap flux that it corrects stator current to achieve fixed exciting current. Then performance of the proposed drive can not be af
APA, Harvard, Vancouver, ISO, and other styles
40

Zhang, Li-sheng, and 張力升. "A Digital Peak Current-Mode Control PFC with Bifurcation Control." Thesis, 2013. http://ndltd.ncl.edu.tw/handle/04289676033925567696.

Full text
Abstract:
碩士<br>國立雲林科技大學<br>電機工程系碩士班<br>101<br>When a boost converter operates under top current control in current-continuous mode with duty cycle greater than 0.5, current experiences perturbation and results in oscillations, also known as sub-harmonic oscillation, quasi-periodic oscillation, and period-doubling oscillation. These undesired oscillations which cause noise, disturb the switch frequency stability and generate higher peak current that significantly decrease the system power. The purpose of this project is to design a 500 W boost power factor corrector that clears the bifurcation current,
APA, Harvard, Vancouver, ISO, and other styles
41

Cai, Kai-cyuan, and 蔡凱全. "Clamp Current Mode Control 'CUK Power Factor Corrector." Thesis, 2013. http://ndltd.ncl.edu.tw/handle/38534468880916958154.

Full text
Abstract:
碩士<br>國立臺灣科技大學<br>電子工程系<br>101<br>This thesis presents an AC-DC converter with negative voltage output. The circuit topology is based on the &apos;CUK power factor correction converter with inherent voltage step-up/down features. The input and output currents are continuous, low ripple currnet can be achieved. Using UC3842 control IC and the clamp current mode control and voltage-follower control, the studied AC-DC converter has high input power factor. The operating principles for the &apos;CUK power factor correction converter, clamp current mode control, voltage-follower control, and slope
APA, Harvard, Vancouver, ISO, and other styles
42

Guo, Zhe-Ming, and 郭哲銘. "A Current-Mode Control Switching-Based Li-Ion Battery Charger with Battery Aged Detection and Trickle Current Mode." Thesis, 2018. http://ndltd.ncl.edu.tw/handle/2544p9.

Full text
Abstract:
碩士<br>國立中正大學<br>電機工程研究所<br>106<br>This thesis presents a current-mode control switching-based charger with detection of battery aging and trickle current mode. The proposed charger uses the current-mode control converter as the basic architecture and adopts constant current and constant voltage (CC-CV) dual modes to achieve battery charging process. A complete Li-ion battery charging process also includes trickle current (TC) charging stage. However, the converter has to operate in DCM in TC stage and results in lower average charging current. In this thesis, linear regulator is used in trickl
APA, Harvard, Vancouver, ISO, and other styles
43

YANG, YUNG-JAN, and 楊詠然. "Implementation of the Non-isolated LED Lighting Source with Constant Current Control." Thesis, 2016. http://ndltd.ncl.edu.tw/handle/01529852507316039068.

Full text
Abstract:
碩士<br>明志科技大學<br>機械工程系機械與機電工程碩士班<br>104<br>The finite nature of fossil-fuel resources and the increasing emphasis on reducing “greenhouse gases” inexorably leads to seeking energy-saving electrical products. Light Emitting Devices [LEDs] are a major saviour in this field due to the significant savings in consumption which can be achieved.The rapid development of LEDs --- initially from the low light indicator to the high brightness light source, has substantially resulted in not only increasing the quantity of lumens but also their luminous efficiency. This brings LEDs to the trend of general
APA, Harvard, Vancouver, ISO, and other styles
44

Lin, Guan-Yu, and 林冠宇. "The DCM Stability Issue of Voltage Regulators Using a Current-Mode Constant On-Time Controller." Thesis, 2013. http://ndltd.ncl.edu.tw/handle/69815715937133697001.

Full text
Abstract:
碩士<br>國立臺灣大學<br>電機工程學研究所<br>101<br>In recent years, constant on-time (COT) controllers for voltage regulators (VR) have received much attention because of their characteristics of high conversion efficiency under light-load conditions. Among the varieties of COT controllers, the current-mode version in combination with a DC output voltage offset correction (OC) circuit is considered in this thesis. In the past, discontinuous-conduction mode (DCM) operation has been considered trivial and there was no stability problem under such a condition. However, it was observed, in practice, instability c
APA, Harvard, Vancouver, ISO, and other styles
45

Hsu, Chih-Jen, and 許智禎. "Current Mode Control Integrated Circuit with High Accuracy Current Sensing Circuit for Buck Converters." Thesis, 2008. http://ndltd.ncl.edu.tw/handle/41597128590597467822.

Full text
Abstract:
碩士<br>輔仁大學<br>電子工程學系<br>96<br>The current-mode controlled DC-DC converters provide a more accurate output voltage for a wide loading range because of the easy compensation. Besides, both the line regulation and load regulation of the current-mode controlled DC-DC converters are better than those of the voltage-mode controlled DC-DC converters because of dual loops. However, the complexity of the current-mode controlled DC-DC converter is higher than of the voltage-mode controlled DC-DC converter. In addition to an output voltage feedback loop, there exists an inner current feedback loop to con
APA, Harvard, Vancouver, ISO, and other styles
46

Chen, Chien-cheng, and 陳建成. "A High Efficiency Current Mode Control DC-DC Buck Converter." Thesis, 2010. http://ndltd.ncl.edu.tw/handle/07494232505610402844.

Full text
Abstract:
碩士<br>國立中央大學<br>電機工程研究所<br>99<br>In this changing rapidly era of electronic technology, the major demands of portable electronics are short, thin, and full functionalities. These sub-circuits of the portable electronics, which use batteries for power sources, need a stable supply voltage generating by power converters. These power converters must have low power consumption and high efficiency to extend the service time of portable electronics. Thus, a high efficiency current mode buck converter is presented in this thesis. The proposed buck converter uses current-mode controlling mechanism to
APA, Harvard, Vancouver, ISO, and other styles
47

Chang, Wei-Hsun, and 張偉勛. "An Integrated DCM Buck Converter with Peak-current mode Control." Thesis, 2009. http://ndltd.ncl.edu.tw/handle/77187575206338634170.

Full text
Abstract:
碩士<br>國立成功大學<br>電機工程學系碩博士班<br>97<br>An integrated DCM buck converter with peak-current mode control is presented in this thesis, and a systematic procedure including system level, circuit level and transistor level is introduced. Mathcad, SIMPLIS and HSPICE are used to simulated, respectively. The DC–DC converter is fabricated with a TSMC 0.35um CMOS technology and the chip area is 1.423 x 0.812 mm2. Experimental results show that this converter can operate 500kHz with supply voltage from 2.7 to 4.2 V, which is suitable for single-cell lithium-ion battery supply applications. The output voltag
APA, Harvard, Vancouver, ISO, and other styles
48

Hu, Chin-Chun, and 胡志俊. "Implementation of PWM Current-Mode Control CMOS Buck Power Converter." Thesis, 2015. http://ndltd.ncl.edu.tw/handle/09191458267284545439.

Full text
Abstract:
碩士<br>亞東技術學院<br>資訊與通訊工程研究所<br>103<br>In recent years, the portable electronic products, such as smart phones, wearable device, and even SOC embedded system, etc. grow fast. To meet the needs of today market which is toward compact size and wireless transmission, it is anticipated to have a long working hours and standby time. Therefore requiring higher power conversion efficiency, fast transient response and stability of the power supply of the power converter is design issues. In this Thesis, a current-mode CMOS PWM control buck converter is implemented for above applications. The circuit str
APA, Harvard, Vancouver, ISO, and other styles
49

Chen, Chih-Wei, and 陳治瑋. "Tolerance Analysis of a Constant On-Time Current-Mode Voltage Regulator with Adaptive Voltage Position Feature." Thesis, 2013. http://ndltd.ncl.edu.tw/handle/74643432336932285001.

Full text
Abstract:
碩士<br>國立臺灣大學<br>電機工程學研究所<br>101<br>In the past, the DC-DC converters used for computer power applications usually employ a constant-frequency variable-duty-cycle controller. This type of control, however, often causes low conversion efficiency under light-load conditions. In recent years, light-load efficiency has become a major design consideration for the reason that most of the electronic devices, whether for desk-top or hand-held applications, are most of the time operated under light-load conditions. Therefore, a new controller type, the constant-on-time controller, has been proposed and
APA, Harvard, Vancouver, ISO, and other styles
50

Yang, Yu-Chun, and 楊毓群. "Charge Pump with Zero Reverse Current , Constant Switch On-Resistance and Frequency Control." Thesis, 2014. http://ndltd.ncl.edu.tw/handle/70827749537230448442.

Full text
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!