To see the other types of publications on this topic, follow the link: Dental impression materials.

Dissertations / Theses on the topic 'Dental impression materials'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 36 dissertations / theses for your research on the topic 'Dental impression materials.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.

1

Lawson, Nathaniel C. "Mechanical properties of dental impression materials." Birmingham, Ala. : University of Alabama at Birmingham, 2007. https://www.mhsl.uab.edu/dt/2008r/lawson.pdf.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Shah, Amit. "Surface reproducibility of impression materials." Thesis, Birmingham, Ala. : University of Alabama at Birmingham, 2007. http://www.mhsl.uab.edu/dt/2007m/shah.pdf.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Cid, Galano Marcos. "Linear expansion of dental stone after its final set and beyond two hours." Morgantown, W. Va. : [West Virginia University Libraries], 2003. http://etd.wvu.edu/templates/showETD.cfm?recnum=2935.

Full text
Abstract:
Thesis (M.S.)--West Virginia University, 2003.
Title from document title page. Document formatted into pages; contains viii, 43 p. : ill. Vita. Includes abstract. Includes bibliographical references (p. 41-42).
APA, Harvard, Vancouver, ISO, and other styles
4

Zeiaei-Nafchi, Saeid. "Dimensional changes of poysulfide [sic] impression materials over time." Morgantown, W. Va. : [West Virginia University Libraries], 2000. http://etd.wvu.edu/templates/showETD.cfm?recnum=1300.

Full text
Abstract:
Thesis (M.S.)--West Virginia University, 2000.
Title from document title page. Document formatted into pages; contains vii, 47 p. : ill. (some col.) Vita. Includes abstract. Includes bibliographical references (p. 41-46).
APA, Harvard, Vancouver, ISO, and other styles
5

Walmsley, P. G. S. "Surface characteristics of vinyl polysiloxane impression materials /." Title page, summary and contents only, 1991. http://web4.library.adelaide.edu.au/theses/09DM/09dmw216.pdf.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Damodara, Eswar Keran C. "Clinical trial to determine the accuracy of prefabricated trays for making alginate impressions." Thesis, Birmingham, Ala. : University of Alabama at Birmingham, 2008. https://www.mhsl.uab.edu/dt/2009r/damodara.pdf.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Osio, Mary A. "The effect of storage time on dimensional accuracy of elastomeric impression materials." Thesis, University of the Western Cape, 2008. http://etd.uwc.ac.za/index.php?module=etd&action=viewtitle&id=gen8Srv25Nme4_1324_1259228236.

Full text
Abstract:

"
Several factors play a role in stability of impressions made from elastomeric impression materials. These include
polymerization shrinkage, loss of by-products during condensation, thermal contraction from oral temperature to room temperature, imbibition when exposed to water, disinfectant or high humidity and incomplete recovery from deformation due to viscoelastic behavior. An ideal impression material should be dimensionally stable over time to allow for pour at the convenience of the operator. Several studies evaluated the dimensional accuracy of elastomeric impression materials based on various factors including effects of repeat pour, temperature, humidity, disinfectants, impression techniques, and filler loading amongst others. Most of the previous studies did not use the standardized method described by the ADA specification for elastomeric impression materials..."

APA, Harvard, Vancouver, ISO, and other styles
8

Pamenius, Madeleine Jansson. "Rubber impression materials, a mechanical approach an investigation of material properties and their application in computer simulation of dimensional stability /." Stockholm : Division of Dental Materials and Technology, Dept. of Clinical Oral Sciences, School of Dentistry, Karolinska Institutet, 1994. http://catalog.hathitrust.org/api/volumes/oclc/30989203.html.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Messias, Aion Mangino. "Influência de técnicas e materiais de moldagem, tempos e materiais de vazamento na exatidão tridimensional de modelos /." Araraquara, 2019. http://hdl.handle.net/11449/183323.

Full text
Abstract:
Orientador: José Maurício dos Santos Nunes Reis
Resumo: Este estudo analisou a exatidão de modelos totais de gesso, obtidos a partir de diferentes técnicas e materiais de moldagem, tempos e materiais de vazamento, levando em consideração as mensurações de área, volume e angulação nos eixos X, Y e Z de pontos de referência específicos em modelo mestre (baseline), moldes e, por posteriormente, em modelos de gesso de cada condição experimental. Foi utilizado um modelo mestre com preparos nos dentes 14, 16, 21 e 25, com demarcações pontuais em suas superfícies oclusais, que funcionavam como pontos de referência. Realizaram-se três técnicas de moldagem: (T1) mistura simultânea, (T2) reembasamento - alívio com filme de PVC e (T3) moldagem digital (escâner intra-oral) - Cerec Conect Omnicam (Sirona). Para cada técnica de moldagem/tempo de vazamento foram obtidos 8 moldes totais, por único operador calibrado (ICC=0,99), com moldeira metálica de estoque e silicone de condensação (Speedex; Coltène/Whaledent Inc.) ou adição (Express XT; 3M ESPE). Os vazamentos foram realizados com gessos tipo IV convencional (GC Fuji Rock EP - GC America) e de expansão nula (Zero Stone - Dentona AG). Nos moldes com silicone de condensação o gesso foi vazado após 30 minutos, 3 ou 7 dias. Nos moldes em silicone de adição os modelos foram obtidos após 2 horas, 3, 7 ou 15 dias. Para a análise tridimensional, utilizou-se software para gerenciamento de imagens e análise das malhas tridimensionais (Rhinoceros - versão 5.3.2) obtidas com escâner óptico de bancada (R... (Resumo completo, clicar acesso eletrônico abaixo)
Abstract: This study analyzed the accuracy of total gypsum casts obtained from different casting techniques and materials, casting times and materials, taking into account the measurements of area, volume and angulation in the X, Y and Z axes of reference points specific master model (baseline), in the impression and, later, in the gypsum casts of each experimental condition. A master model was used with teeth 14, 16, 21 and 25, with punctual demarcations on its occlusal surfaces, which functioned as reference points. Three impression techniques were performed: (T1) simultaneous mixing, (T2) relining-relief with PVC film and (T3) chairside digital impression - Cerec Conect Omnicam (Sirona). For each impression technique / casting time, 8 total impression were obtained by single calibrated operator (ICC = 0.99), with metal stock tray and condensation silicone (Speedex; Coltène / Whaledent Inc.) or addition (Express XT 3M ESPE). The gypsum casts pouring process were performed with type IV conventional gypsum (GC Fuji Rock EP - GC America) and zero expansion one (Zero Stone - Dentona AG). For impressions with condensation silicone the cast was poured after 30 minutes, 3 or 7 days. For the addition silicone impressions, the gypsum casts were obtained after 2 hours, 3, 7 or 15 days. For the three-dimensional analysis, a software was used to manage threedimensional images (Rhinoceros - version 5.3.2) allowing the investigation of virtual images (three-dimensional meshes) made with an optical... (Complete abstract click electronic access below)
Doutor
APA, Harvard, Vancouver, ISO, and other styles
10

Al-Mortadi, Noor Abdullah Abdullah. "The need for and effects upon dental impression and laboratory die materials of an alternative prion disinfection regime." Thesis, University of Dundee, 2009. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.505628.

Full text
APA, Harvard, Vancouver, ISO, and other styles
11

Daniela, Đurović Koprivica. "Uticaj metoda otiskivanja i angulacije implanata na tačnost definitivnog radnog modela za izradu implantno nošenih zubnih nadoknada." Phd thesis, Univerzitet u Novom Sadu, Medicinski fakultet u Novom Sadu, 2017. https://www.cris.uns.ac.rs/record.jsf?recordId=104798&source=NDLTD&language=en.

Full text
Abstract:
U uvodnom delu doktorske disertacije opisane su osnovne konvencionalne metode otiskivanja, kao i modifikovane tehnike koje se koriste u savremenoj implant protetici. Prikazana je specifičnost biomehanike implantno nošenih i poduprtih nadoknada u odnosu na biomehaniku nadoknada retiniranih prirodnim zubima. Akcenat je stavljen na kompleksnost problematike postizanja apsolutno pasivnog naleganja nadoknade na nosač implanta (abatment), sa posebnim osvrtom na uticaj same procedure otiskivanja implanata i angulacije implanata na tačnost naleganja. Detaljno su opisani i svi ostali faktori koji mogu da utiču na tačnost radnih modela pri izradi nadoknada na implantima, pozivajući se na aktuelne podatke iz literature i naučno opravdanje za potrebe istraživanja. Cilj rada je bio ispitati uticaj metode otiskivanja, angulacije implanata i vrste otisnog materijala na tačnost definitivnog radnog modela za izradu implantno nošenih zubnih nadoknada. Eksperiment je obavljen u in vitro uslovima. Istraživanje je bazirano na ispitivanju tačnosti otiskivanja pomoću tri različite metode otiskivanja (direktne, indirektne i modifikovane „splint“ metode), dve vrste elastičnih otisnih materijala (adicionog silikona i polietra) i uticaja dve različite grupe implanata (anguliranih od 20° i paralelnih implanata) na tačnost otiskivanja. Master (referentni) model je isplaniran tako da simulira čest klinički slučaj parcijalne bezubosti gornje vilice (klasa Kenedi I), koji je osim dva ugrađena angulirana implanta sa jedne, i dva paralelna implanta sa druge strane, podrazumevao i prisustvo brušenih zuba, pripremljenih za prihvatanje keramičkog mosta u frontalnoj regiji. Otiskivanje zuba i implanata vršeno je istovremeno i drugi deo istraživanja je obuhvatao ispitivanje uticaja primenjene metode i materijala na tačnost otisnutih površina zuba. Time je prošireno polje istraživanja i omogućeno donošenje zaključka o pravoj indikaciji metode i materijala za otiskivanje konkretnog kliničkog slučaja. Kompletna metodologija izrade master i definitivnih radnih (replika) modela, kao i sama procedura otiskivanja, izvedena je po najsavremenijim principima istraživanja, uz upotrebu instrumenata i materijala vodećih svetskih proizvođača. Za potrebe analize odstupanja implanata i zuba na replica modelima u odnosu na referentni, modeli su podvrgnuti optičkoj 3D (trodimenzionalnoj) digitalizaciji pomoću dva savremena laboratorijska skenera koje karakteriše izuzetna tačnost skeniranih površina. Prvo je digitalizovan master model za potrebe dobijanja nominalne geometrije, a nakon toga 30 replika modela, za potrebe uporedne geometrijske analize. Analiza je vršena pomoću najnovijeg specijalizovanog softverskog programa, primenom metode CAD-inspekcije (eng. Computer-Aided Design). Geometrijska analiza odstupanja brušenih zuba (patrljaka) izvedena je tehnikom preklapanja odnosno superpozicije (eng. bestfit) realne geometrije (na replika modelu) sa nominalnom geometrijom (na master modelu). Za razliku od analize patrljaka, za potrebe geometrijske analize odstupanja implanata kreiran je lokalni koordinatni sistem za svaki analizirani implant, pomoću specijalnih abatmenta upotrebljenih za digitalizaciju i uvozom 3D modela implanata iz CAD biblioteke proizvođača. Odstupanja su analizirana u odnosu na centar baze implanta (odstupanje od centra) i u odnosu na centralnu osu implanta (ugao odstupanja), što je omogućilo tačno prostorno orijentisanje implanata na replika modelima u poređenju sa referentnim. Ova metodologija je originalna, jer je u odnosu na metodologije koje su do sada korišćene u svrhu prostorne orijentacije implanata, uvođenjem novih parametara u analizu, omogućila tačnije defi nisanje prostornog odstupanja analiziranih implanata. Rezultati dobijeni u istraživanju doveli su do zaključka da metoda otiskivanja i vrsta otisnog materijala utiču na tačnost otiskivanja implanata. Takođe, angulacija implanata od 20° ima veći uticaj na tačnost definitivnih radnih modela u poređenju sa paralelnim angulirana implanta sa jedne, i dva paralelna implanta sa druge strane, podrazumevao i prisustvo brušenih zuba, pripremljenih za prihvatanje keramičkog mosta u frontalnoj regiji. Otiskivanje zuba i implanata vršeno je istovremeno i drugi deo istraživanja je obuhvatao ispitivanje uticaja primenjene metode i materijala na tačnost otisnutih površina zuba. Time je prošireno polje istraživanja i omogućeno donošenje zaključka o pravoj indikaciji metode i materijala za otiskivanje konkretnog kliničkog slučaja. Kompletna metodologija izrade master i definitivnih radnih (replika) modela, kao i sama procedura otiskivanja, izvedena je po najsavremenijim principima istraživanja, uz upotrebu instrumenata i materijala vodećih svetskih proizvođača. Za potrebe analize odstupanja implanata i zuba na replika modelima u odnosu na referentni, modeli su podvrgnuti optičkoj 3D (trodimenzionalnoj) digitalizaciji pomoću dva savremena laboratorijska skenera koje karakteriše izuzetna tačnost skeniranih površina. Prvo je digitalizovan master model za potrebe dobijanja nominalne geometrije, a nakon toga 30 replika modela, za potrebe uporedne geometrijske analize. Analiza je vršena pomoću najnovijeg specijalizovanog softverskog programa, primenom metode CAD-inspekcije (eng. Computer-Aided Design). Geometrijska analiza odstupanja brušenih zuba (patrljaka) izvedena je tehnikom preklapanja odnosno superpozicije (eng. bestfit) realne geometrije (na replika modelu) sa nominalnom geometrijom (na master modelu). Za razliku od analize patrljaka, za potrebe geometrijske analize odstupanja implanata kreiran je lokalni koordinatni sistem za svaki analizirani implant, pomoću specijalnih abatmenta upotrebljenih za digitalizaciju i uvozom 3D modela implanata iz CAD biblioteke proizvođača. Odstupanja su analizirana u odnosu na centar baze implanta (odstupanje od centra) i u odnosu na centralnu osu implanta (ugao odstupanja), što je omogućilo tačno prostorno orijentisanje implanata na replika modelima u poređenju sa referentnim. Ova metodologija je originalna, jer je u odnosu na metodologije koje su do sada korišćene u svrhu prostorne orijentacije implanata, uvođenjem novih parametara u analizu, omogućila tačnije definisanje prostornog odstupanja analiziranih implanata. Rezultati dobijeni u istraživanju doveli su do zaključka da metoda otiskivanja i vrsta otisnog materijala utiču na tačnost otiskivanja implanata. Takođe, angulacija implanata od 20° ima veći uticaj na tačnost definitivnih radnih modela u poređenju sa paralelnim implantima. Time su potvrđene radne hipoteze doktorske disertacije. „Splint“ metoda otiskivanja i adicioni silikon izdvojili su se kao najtačniji pri otiskivanju implanata. Kombinacije „splint“ metode sa adicionim silikonom i polietrom i otvorene metode sa adicionim silikonom dale su bolje rezultate pri otiskivanju anguliranih implanta, dok je u grupi paralelnih implanata zaključeno da metoda i materijal ne utiču na tačnost otiskivanja. „Splint“ i otvorena metoda i adicioni silicon pružili su najtačnije otiske brušenih zuba. „Splint“ metoda u kombinaciji sa adicionim silikonom dala je najmanja ukupna odstupanja pri otiskivanju implanata i zuba zajedno. Prezentovana studija je specifi čna, kako po izboru zadatog kliničkog slučaja I uporednoj analizi tačnosti istovremenog otiskivanja implanata i zuba, tako i po samoj metodologiji analiza odstupanja implanata, te predstavlja originalni doprinos naučnoj i stručnoj javnosti.
The introductory part of the PhD-theses describes fundamental conventional impression methods, as well as modified techniques used in modern-day implant prosthetics. The biomechanics specificity of the implant supported prosthesis in relation to the biomechanics of natural-teeth retained prosthetics is showed. The emphasis is on the issue’s complexity at accomplishing the absolute passive fit of the prosthesis onto the abutment, with particular regard to the impact of the implant impression procedure and implant angulation its elf. A detailed description is provided for all other factors which can influence the accuracy of working casts during implant-based dental prosthesis, making reference to the current data in the literature, as well as to the scientific justification for research. The aim of the study was to examine the influence of the impression method, implant angulation and type of the impression material on the accuracy of the definitive working model for production of the implant-supported dental prosthesis. The experiment was conducted in the in vitro conditions. The research is based on examining the impression accuracy by using three different impression methods (direct, indirect, as well as modifi ed “splint” method), by using two types of elastic impression materials (addition silicone and polyether), as well as the impact from two different implant groups (angled at 20°, and parallel ones). Master (referential) model was planned to simulate a common clinical case of the upper jaw partial edentulism (Kennedy 1st class), which apart from the two angulated implants on one side, and two parallel implants on the other, also presupposed presence of milled teeth, prepared to accept ceramic dental bridge in the frontal region. Impression of teeth and implants was conducted simultaneously, and second part of the research encompassed examination of the applied method’s and material’s impact onto accuracy of the impressed teeth surfaces. This expanded the research fi eld and enabled drawing conclusions regarding the appropriate method indication and material for impression of a particular clinical case. Complete production methodology of master and definitive working casts (replicas), as well as the impression procedure itself, were all conducted according to the cutting-edge research principles, as well as with the application of instruments and materials of leading world producers. For the purpose of the analysis of implants and teeth deviation on replica models in relation to the reference model, the models underwent optical 3D (three-dimenzional) digitalization by using two state-of-the-art laboratory scanners characterized by exceptional accuracy of scanned surfaces. First model to be digitalized was the master one, in order to obtain nominal geometry, following which 30 model replicas were scanned, for the purpose of comparative geometrical analysis. The analysis was conducted by using latest specialized software designed for CAD (Computer-Aided Design) inspection method. Geometric analysis of the milled teeth (tooth abutments) deviation was conducted by using the overlapping superposition technique (bestfit) real geometry (on the replica model) with nominal geometry (on the master model). As opposed to the teeth-stump analysis, for the purpose of geometrical analysis of implant deviations, a local coordinate system for each analyzed implant was created, by using special abutments used for digitalization and by importing 3D implant models from the manufacturer’s CAD library. Deviations were analyzed in relation to the implant base center (deviation from the center), and in relation to the implant central axis (deviation angle), which enabled accurate implant spatial orientation on the replica models in comparison the referential ones. This methodology is original, since unlike methodologies used so far for implant spatial orientation, it has enabled, through introducing new parameters into analysis, a more accurate defining of analyzed implants spatial deviation. Results obtained during research have led to the conclusion that that the impression methodology and type of the impression material influence the implant impression accuracy. Also, implant angulation of 20° has a higher impact on accuracy of definitive working models in comparison with parallel implants. This confirms the PhD-thesis working hypotheses. The “splint” impression method and addition silicone have excelled as most accurate at implant impression. Combination of “splint” methods with addition silicone and polyether and opened methods with addition silicone proved to obtain better results when impressing angulated implants, while in the group of parallel implants, it was concluded that the method and material do not infl uence the impression accuracy. The “splint” and the open method and addition silicone provided most accu rate imprints of ground teeth. The “splint” method in com bination with addition silicone provided the least over all deviation at impression of implants and teeth together. The presented study is a specifi c one, both in terms of selection of the given clinical case and comparative analysis of the simultaneous impression of teeth and implants, but also in terms of the methodology itself used to analyze implant deviation, which in its own right represents an original contribution to the scientific and expert public.
APA, Harvard, Vancouver, ISO, and other styles
12

Amaral, Ângela Líbia Chagas [UNESP]. "Análise comparativa de técnicas de moldagem para próteses implantossuportadas." Universidade Estadual Paulista (UNESP), 2009. http://hdl.handle.net/11449/98031.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:29:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-03-20Bitstream added on 2014-06-13T18:58:44Z : No. of bitstreams: 1 amaral_alc_me_arafo.pdf: 1042757 bytes, checksum: 04d3deeb31a2a6595b470bc935ceb48d (MD5)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Proposta: A proposta deste estudo in vitro foi avaliar 3 técnicas de moldagem (Cônico, Hélice e Unido com barra) para próteses implantossuportadas. Materiais e métodos: Um modelo mandibular em latão contendo 4 análogos de implantes e uma estrutura metálica foram confeccionados. Foram utilizados 2 materiais de moldagem: Silicona de polimerização por adição (Express STD, 3M ESPE) e Silicona de polimerização por condensação (Zetaplus/Oranwash, Zermack). Seis grupos foram formados pela combinação entre cada material e técnica de moldagem. Um total de 30 modelos foram fabricados (5 modelos por grupo) e 120 valores de fendas foram analisados (1 valor de fenda para cada análogo de implante). Resultados: Para o material Express, os valores médios de fenda foram: 164,40 μm (Cônico), 97,90 μm (Hélice) e 127,79 μm (Unido). Para o material Zetaplus/Oranwash, os valores médios de fenda foram: 219,37 μm (Cônico), 118,57 μm (Hélice) e 78,50 μm (Unido). Houve uma diferença estatística significante entre o Cônico e a Hélice para o material Express (p<.05). Quando o material avaliado foi o Zetaplus/Oranwash, todos os grupos foram diferentes estatisticamente entre si (p<.05). Conclusões: Os melhores resultados foram alcançados para a Hélice e para Unido quando o material avaliado foi o Express. Para o Zetaplus/Oranwash, a melhor técnica foi o Unido, seguida da Hélice e do Cônico.
Purpose: The purpose of this in vitro study was to evaluate 3 impression techniques (tapered impression copings, squared modified impression copings, and squared impression copings splinted with bur and acrylic resin) for implant-supported prosthesis. Materials and Methods: A mandibular brass cast with 4 stainless steel implant-abutments analogs and a framework were fabricated. Addition silicone – Express – and condensation silicone – Zetaplus/Oranwash - impression materials were tested. Six groups were formed by combining each material and impression technique. Five casts were made per group for a total of 30 casts and 120 gap values (1 gap value for each implant-abutment analog). Results: With the Express impression material, the mean gap values were 164.40 μm for the tapered group, 97.90 μm for squared modified group and 127.79 μm for squared splinted group. With the Zetaplus/Oranwash impression materials, the mean gap values were 219.37 μm for the tapered group, 118.57 μm for squared modified group and 78.50 μm for squared splinted group. There was significantly difference between tapered impression technique and squared modified impression technique (P<.05), when the material was Express. When the material was the condensation silicone, all groups had significantly difference among themselves (P<.05). Conclusions: The best results were achieved for squared modified impression technique and squared splinted impression techniques, when the impression material was Express. For condensation silicone, the best technique was squared splinted group, followed by squared modified group, and tapered group.
APA, Harvard, Vancouver, ISO, and other styles
13

Amaral, Ângela Líbia Chagas. "Análise comparativa de técnicas de moldagem para próteses implantossuportadas /." Araraquara : [s.n.], 2009. http://hdl.handle.net/11449/98031.

Full text
Abstract:
Orientador: Francisco de Assis Mollo Junior
Banca: João Neudenir Arioli Filho
Banca: Mauro Antônio de Arruda Nóbilo
Resumo: Proposta: A proposta deste estudo in vitro foi avaliar 3 técnicas de moldagem (Cônico, Hélice e Unido com barra) para próteses implantossuportadas. Materiais e métodos: Um modelo mandibular em latão contendo 4 análogos de implantes e uma estrutura metálica foram confeccionados. Foram utilizados 2 materiais de moldagem: Silicona de polimerização por adição (Express STD, 3M ESPE) e Silicona de polimerização por condensação (Zetaplus/Oranwash, Zermack). Seis grupos foram formados pela combinação entre cada material e técnica de moldagem. Um total de 30 modelos foram fabricados (5 modelos por grupo) e 120 valores de fendas foram analisados (1 valor de fenda para cada análogo de implante). Resultados: Para o material Express, os valores médios de fenda foram: 164,40 μm (Cônico), 97,90 μm (Hélice) e 127,79 μm (Unido). Para o material Zetaplus/Oranwash, os valores médios de fenda foram: 219,37 μm (Cônico), 118,57 μm (Hélice) e 78,50 μm (Unido). Houve uma diferença estatística significante entre o Cônico e a Hélice para o material Express (p<.05). Quando o material avaliado foi o Zetaplus/Oranwash, todos os grupos foram diferentes estatisticamente entre si (p<.05). Conclusões: Os melhores resultados foram alcançados para a Hélice e para Unido quando o material avaliado foi o Express. Para o Zetaplus/Oranwash, a melhor técnica foi o Unido, seguida da Hélice e do Cônico.
Abstract: Purpose: The purpose of this in vitro study was to evaluate 3 impression techniques (tapered impression copings, squared modified impression copings, and squared impression copings splinted with bur and acrylic resin) for implant-supported prosthesis. Materials and Methods: A mandibular brass cast with 4 stainless steel implant-abutments analogs and a framework were fabricated. Addition silicone - Express - and condensation silicone - Zetaplus/Oranwash - impression materials were tested. Six groups were formed by combining each material and impression technique. Five casts were made per group for a total of 30 casts and 120 gap values (1 gap value for each implant-abutment analog). Results: With the Express impression material, the mean gap values were 164.40 μm for the tapered group, 97.90 μm for squared modified group and 127.79 μm for squared splinted group. With the Zetaplus/Oranwash impression materials, the mean gap values were 219.37 μm for the tapered group, 118.57 μm for squared modified group and 78.50 μm for squared splinted group. There was significantly difference between tapered impression technique and squared modified impression technique (P<.05), when the material was Express. When the material was the condensation silicone, all groups had significantly difference among themselves (P<.05). Conclusions: The best results were achieved for squared modified impression technique and squared splinted impression techniques, when the impression material was Express. For condensation silicone, the best technique was squared splinted group, followed by squared modified group, and tapered group.
Mestre
APA, Harvard, Vancouver, ISO, and other styles
14

Monteiro, Wildes da Costa. "Avaliação das alterações dimensionais em modelos de gesso para protese total por meio de medição tridimensional em função de materiais e tecnicas de moldagem." [s.n.], 2005. http://repositorio.unicamp.br/jspui/handle/REPOSIP/290120.

Full text
Abstract:
Orientador: Simonides Consani
Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-04T11:55:19Z (GMT). No. of bitstreams: 1 Monteiro_WildesdaCosta_D.pdf: 6985087 bytes, checksum: dab5ef3ae95601eac48a0d542f0cf87f (MD5) Previous issue date: 2005
Resumo: O objetivo deste estudo foi analisar por meio de medições tridimensionais, as alterações dimensionais que ocorrem nos modelos de gesso utilizados na confecção de prótese total, em função de diferentes materiais para moldagem: silicone, alginato e godiva equalizada com alginato. Foram confeccionados 45 modelos de gesso tipo IV, (n=15) construídos a partir de moldes obtidos de um modelo padrão metálico de alumínio, onde foram colocados 7 parafusos com 3,5 mm de diâmetro, para estabelecer pontos referenciais das distâncias a serem mensuradas. Esses pontos referenciais permitiram criar segmentos para o cálculo do volume e da área gerados nas figuras representativas dos modelos de gesso, permitindo avaliar a estabilidade dimensional dos modelos em gesso por meio de medições tridimensionais. No CETEF os modelos de gesso foram submetidos às medições tridimensionais no aparelho Mitutoyo, modelo BLN 710, equipado com cabeça de medição Renishaw PH9 e apalpador TP200 com esfera de 1mm de diâmetro, para as seguintes etapas: 1- transferência das coordenadas tridimensionais para o programa Mechanical Desktop; realização dos desenhos bidimensionais; medição dos seguimentos que compõem cada figura desenhada de cada desenho; realização dos desenhos tridimensionais; cálculo do volume e da área projetada utilizando a malha de elementos finitos e confecção de uma planilha de cálculo para cada material de moldagem; tratamento estatístico dos dados e determinação matemática das variações e das coordenadas x, y e z dos comprimentos de cada um dos segmentos, dos perímetros e das áreas de cada figura dos quarenta e cinco modelos. 2- lançamento dos dados nas planilhas de cálculo; tratamento estatístico dos dados e determinação matemática das variações e das coordenadas x, y e z dos comprimentos de cada um dos segmentos, dos perímetros e das áreas de cada figura. 3- apresentação tridimensional das variações dimensionais encontradas nos modelos; transferência das variações das coordenadas do grupo de modelos de cada material, em relação ao modelo padrão, para o software de desenho 3D ¿ Mechanical Desktop; geração das figuras para visualização das variações e elaboração de relatório técnico. Os resultados foram submetidos à média matemática simples da dispersão ou variação dos dados, que é o grau no qual os dados numéricos da amostra tendem a dispersar-se em torno de um valor médio. Foi utilizado neste trabalho o cálculo do desvio padrão simples. Os moldes feitos com silicone por adição produziram modelos com menor variação dimensional (capacidade de repetitibilidade) quando comparados aos modelos obtidos com moldes de alginato e godiva equalizada com alginato. O alginato produziu modelos com grande fidelidade de cópias em função da matriz metálica
Abstract: The purpose of this study was to analyze, through three-dimensional measurements, the dimensional changes in casts of stone used to make complete dentures, in function of different materials for impression: addition reaction silicone, alginate and impression compound reline with alginate. The casts of stone type IV were made from molds obtained from a metallic standard die of aluminum. In this metallic die were put seven screws with 3,5mm diameter, to establish referential points of the measured distances. The referential points allowed creating segments for the calculation of the area and volume in the representative drawings generated for the stone casts. The procedure allows evaluating the dimensional stability through three-dimensional measurements. In CETEF the stone die were measured with three-dimensional equipment Mitutoyo, model BLN 710, equipped with measurement head Renishaw PH9 and feeler TP200 with sphere of 1mm of diameter, for the stages: 1- Transfer of the three-dimensional coordinates for the program Mechanical Desktop; generation of the two-dimensional drawings; measurement of the segments that compose each drawing; generation of the three-dimensional drawings; projected area determination and volume calculation using the finite elements net; making of a calculation spread sheet for each impression material; statistical treatment of the data and mathematical determination of the variations in the x, y and z coordinates in the lengths of each segments, in the perimeters and in the areas of each drawing of the forty five casts. 2 - Insertion of the data in the calculation spread sheets; statistical treatment of the data and mathematical determination of the variations and in the x, y and z coordinates in the lengths of each one of the segments, in the perimeters and of the areas of each drawing. 3 - Three-dimensional presentation of the dimensional variations found in the models; transfer of the variations of the coordinates of the group of models of each material, for the software of 3D drawing ¿ Mechanical Desktop; generation of the drawings for visualization of the variations and elaboration of technical report. The results were submitted to the simple mathematics medium of the dispersion or variation of the data, that it is the degree, in which the numeric data of the sample tend to disperse around a medium value. It was used in this work the calculation of the simple standard deviation. The molds made with addition reaction silicone produced casts with smaller dimensional variation, when compared to the casts obtained with alginate or impression compound reline with alginate. The silicone presented larger capacity to repeat generated copies of the molds, from the standard die. The cast made with addition reaction silicone presented small variation among themselves when compared to the standard metallic die
Doutorado
Protese Dental
Doutor em Clínica Odontológica
APA, Harvard, Vancouver, ISO, and other styles
15

Monteiro, Jaiane Bandoli. "Avaliação da alteração dimensional de quatro siliconas por condensação através da medição tridimensional por coordenadas." Universidade Federal de Juiz de Fora, 2015. https://repositorio.ufjf.br/jspui/handle/ufjf/87.

Full text
Abstract:
Submitted by Renata Lopes (renatasil82@gmail.com) on 2015-12-03T16:47:38Z No. of bitstreams: 1 jaianebandolimonteiro.pdf: 2039791 bytes, checksum: c3f28c1a95fdef73d0cc0190a9dfa169 (MD5)
Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2015-12-03T21:29:38Z (GMT) No. of bitstreams: 1 jaianebandolimonteiro.pdf: 2039791 bytes, checksum: c3f28c1a95fdef73d0cc0190a9dfa169 (MD5)
Made available in DSpace on 2015-12-03T21:29:38Z (GMT). No. of bitstreams: 1 jaianebandolimonteiro.pdf: 2039791 bytes, checksum: c3f28c1a95fdef73d0cc0190a9dfa169 (MD5) Previous issue date: 2015-04-30
CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
O objetivo foi avaliar a alteração dimensional dos moldes de silicona por condensação imediatamente, 30min, 1h e 7 dias após a moldagem, com o auxílio da máquina de medição tridimensional por coordenadas. Os grupos foram divididos em: G1: Speedex Putty/Speedex Light Body (Coltene/Vigodent AS Indústria e Comércio), G2: Optosil P Plus/Xantopren L Blue (Heraeus Kulzer GmbH), G3: Zetaplus Putty/Oranwash L (Zhermack SpA) e G4: Precise SX (Dentsply Indústria e Comércio Ltda). Para a obtenção das 80 medições dos 4 materiais (n=20), foi usado um dispositivo composto por uma moldeira perfurada e uma outra parte com 3 edentações pré-estabelecidas. Para a avaliação dimensional, a máquina Crysta-Plus M 574 (Mitutoyo) realizou cada medida 3 vezes nos tempos estabelecidos e obteve-se a média aritmética. A média final das 4 distâncias I, II, III e IV do dispositivo edentado foi novamente aplicada. A análise estatística foi realizada com o teste de Kolmogorov-Smirnov que rejeitou a hipótese nula de distribuição assimétrica. Posteriormente, foi feita a ANOVA para comparar os 4 materiais simultaneamente e o teste paramétrico t de Student para comparar os materiais 2 a 2. O nível de significância global foi de p≤0,05. A maior contração linear foi observada na Speedex, mas não foi significante (p=0,08). A Zetaplus Putty/Oranwash L parece ser a mais estável (p=0,99), mas não foi significante. Não houve diferença estatisticamente significante entre nenhuma silicona por condensação quando comparadas simultaneamente nos 4 tempos ou quando comparadas 2 a 2, à exceção, Precise SX e a Speedex (p=0,05) no tempo T3. Todas as siliconas por condensação testadas apresentam alteração dimensional clinicamente aceitável e podem ser vazadas imediatamente, 30min, 1h e 7 dias após a moldagem.
The purpose was to evaluate the dimensional changes of condensation silicone impressions by immediately, 30min, 1h and 7 days after impression, with the help of threedimensional measuring coordinate machine. The groups were divided in: G1: Speedex Putty/Speedex Light Body (Coltène/Vigodent S/A Ind and Com), G2: Optosil P Plus/Xantopren L Blue (Heraeus Kulzer GmbH), G3: Zetaplus Putty/Oranwash L (Zhermack SpA) and G4: Precise SX (Dentsply Ind and Com Ltda). To obtain 80 measurements of 4 material (n=20) was used a device consisting of a perforated tray and one another part with 3 pre-established indentations. For dimensional evaluation, the Crysta-Plus M574 machine (Mitutoyo) held each measurement 3 times at the established times and obtained the arithmetic mean. The final average of the 4 distances of I, II, III and IV the edentulous device was again applied. Statistical analysis was performed using the Kolmogorov-Smirnov test to reject the null hypothesis of asymmetric distribution. Subsequently, ANOVA was performed to compare the four materials simultaneously and Student's t parametric test to compare the 2 by 2 materials. The overall significance level of p≤0,05. The higher linear contraction was observed in Speedex, but was not significant (p=0,08). The Zetaplus Putty/Oranwash L seems to be more stable (p=0,99) but was not significant. There was no significant difference between any silicone condensation compared simultaneously in 4 times or compared 2 by 2, except, Precise SX and Speedex (p=0,05) in T3 time. All tested condensation silicones exhibit clinically acceptable dimensional change and can be leaked immediately, 30min, 1h and 7 days after impression.
APA, Harvard, Vancouver, ISO, and other styles
16

Carvalhal, Cintia Iara Oda 1977. "Efeito do tempo de imersão em soluções desinfetantes na precisão dimensional de moldes confeccionados com materiais elastoméricos." [s.n.], 2011. http://repositorio.unicamp.br/jspui/handle/REPOSIP/288136.

Full text
Abstract:
Orientador: Mário Alexandre Coelho Sinhoreti
Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-18T14:32:23Z (GMT). No. of bitstreams: 1 Carvalhal_CintiaIaraOda_D.pdf: 811504 bytes, checksum: 34b37d5a40e1f8f8c251a1d3d49fb2aa (MD5) Previous issue date: 2011
Resumo: O objetivo neste estudo foi avaliar o efeito das soluções desinfetantes na precisão e estabilidade dimensional de materiais de moldagem elastoméricos. No primeiro capitulo foram utilizados nove elastômeros, sendo três a base de polidimetil siloxano (silicona por condensação) - PDS (Xantopren, Lastic e Clonage), um polissulfeto - PS (Permlastic), um poliéter - PE (Impregum) e quatro polivinil siloxano (silicona por adição) - PVS (Panasil, Express, Futura AD e Adsil). No segundo capitulo, quatro materiais representativos de cada classe de elastômero Xantopren (polidimetil siloxano - PDS); Express (polivinil siloxano - PVS); Permlastic (polissulfeto - PS) e Impregum Soft (poliéter - PE). Todos os materiais foram manipulados de acordo com as instruções dos fabricantes e, em seguida, inseridos em matriz metálica confeccionada de acordo com a especificação da ISO 4823. No primeiro capitulo, as amostras foram distribuídas em três grupos (n=7): sem imersão (controle); imersão em solução de hipoclorito de sódio (NaOCl) a 0,5%, por 10 minutos; imersão em solução de glutaraldeído a 2%, por 10 minutos. Os resultados mostraram que somente os PDS foram influenciados significativamente pela solução desinfetante, apresentando maior contração quando imersos em NaOCl (p<0,05). Para os outros elastômeros, a solução desinfetante não influenciou a alteração dimensional. Os moldes de PDS apresentaram maio contração que aos demais elastômeros, que não diferiram entre si. No segundo capitulo, as amostras foram submetidas à imersão nas soluções desinfetantes (hipoclorito de sódio a 0,5% e glutaraldeído a 2%) por 5, 10, 20, 30 e 60 minutos (n=7), exceto o grupo controle. A análise de variância a três critérios e o teste de Tukey, com nível de significância de 5%, mostraram que as diferenças nas dimensões lineares dos materiais analisados não foram estatisticamente significantes (p>0,05) após sua imersão em solução de hipoclorito de sódio a 0,5% e glutaraldeído a 2%, nos períodos de tempo avaliados. De modo geral, pôde-se concluir que as combinações dos material de moldagem e solução desinfetante podem ser empregadas na clínica odontológica para desinfecção, sem alterar dimensionalmente os moldes nos períodos de imersão não maiores que 20 minutos
Abstract: The aim of this study was to evaluate the effects of disinfectant solutions on the dimensional stability of elastomeric impression materials. At the first chapter, three polydimethyl siloxane - PDS (Xantopren, Lastic and Clonage), one polysulphide - PS (Permlastic), one polyether - PE (Impregum) and four polyvinyl siloxane - PVS (Panasil, Express, Futura AD and Adsil) were used and at the second chapter just one product of each material were used: Xantopren (polydimethyl siloxane - PDS); Express (polyvinyl siloxane - PVS); Permlastic (polysulphide - PS) e Impregum Soft (polyether - PE). The samples were mixed according to the manufacturer. The dimensional stability was evaluated according to ISO 4823. At the first chapter, the samples were distributed in three groups (n=7): no immersion in solutions (control); immersion in Sodium Hypochlorite solution (NaOCl) 0,5%, for 10 minutes; immersion in Glutaraldehyde solution 2%, for 10 minutes. The results showed that disinfectant solutions altered significantly the dimensional stability only for PDS which presented higher shrinkage when immersed in (p<0.05). For other elastomeric materials, the disinfectant solution did not influence the dimensional stability, which did not differ to each other. The samples of PDS showed higher contraction than the others, which did not differ to each other. At the second chapter, the samples were removed from the pattern after 7 minutes and subjected to immersion in the disinfected solutions (Sodium Hypochlorite solution 0,5% and Glutaraldehyde 2%) for 5, 10, 20, 30 e 60 minutes (n=7), except the control group. The analysis of variance and Tukey's test (p>0.05), showed the difference in linear dimensions of the materials analyzed were not statistically significant (p>0.05) after immersion in Sodium Hypochlorite solution 0,5% and Glutaraldehyde 2%, in those periods of time. In general, it was concluded that the tested combinations of impression material and disinfecting solution can be employed for infection control in clinical use, without changing the dimensional stability in immersion periods not longer than 20 minutes
Doutorado
Materiais Dentarios
Doutor em Materiais Dentários
APA, Harvard, Vancouver, ISO, and other styles
17

Silva, Stephania Caroline Rodolfo [UNESP]. "Influência de técnicas de moldagem com e sem casquetes na exatidão dimensional de modelos de gesso e adaptação marginal de infraestruturas em zircônia." Universidade Estadual Paulista (UNESP), 2016. http://hdl.handle.net/11449/143095.

Full text
Abstract:
Submitted by Stephania Caroline Rodolfo Silva null (stephaniacrsilva@foar.unesp.br) on 2016-08-18T20:52:01Z No. of bitstreams: 1 Dissertação Defesa Stephania C. R. Silva 18.08.pdf: 885533 bytes, checksum: cf1bd5bf272a148a2e397dbde32c3029 (MD5)
Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-08-19T20:19:26Z (GMT) No. of bitstreams: 1 silva_scr_me_arafo.pdf: 885533 bytes, checksum: cf1bd5bf272a148a2e397dbde32c3029 (MD5)
Made available in DSpace on 2016-08-19T20:19:26Z (GMT). No. of bitstreams: 1 silva_scr_me_arafo.pdf: 885533 bytes, checksum: cf1bd5bf272a148a2e397dbde32c3029 (MD5) Previous issue date: 2016-06-20
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
O presente estudo analisou a exatidão de modelos de gesso, obtidos a partir de diferentes técnicas de moldagem, incluindo casquetes individuais, isolados ou unidos, bem como mensurou o desajuste marginal cervical de infraestruturas de zircônia sobre preparos dentais para coroa total. Foi utilizado um modelo mestre (controle), com preparos nos dentes 14, 16, 21 e 25, sobre o qual infraestruturas de zircônia foram confeccionadas por tecnologia CAD/CAM. Para cada técnica de moldagem: simultânea com silicone de condensação (T1a), ou adição (T1b); casquetes individuais isolados (T2); unidos com cilindros de resina acrílica (T3); unidos com cilindros metálicos (T4); foram obtidos 8 moldes totais, por único operador calibrado, com moldeira de estoque. As moldagens com casquetes foram realizadas com poliéter e as transferências com silicone de condensação. Para a análise da adaptação marginal cervical das infraestruturas de zircônia, as mesmas foram passivamente adaptadas sobre os preparos nos modelos de gesso, sendo as mensurações do desajuste marginal cervical realizadas em estereomicroscópio (50x). Para a análise de exatidão dimensional linear oclusal global, os modelos foram escaneados e, a partir de três pontos pré-definidos, realizadas mensurações látero-laterais (LL) e anteroposteriores (AP) bilaterais do arco dental no programa ImageJ. Além disso, mensurações das dimensões áxio-cervicais de cada preparo e da distância entre os preparos do segmento 14-16 foram realizadas com paquímetro digital. Métodos estatísticos (α=0,05) foram empregados para avaliar a influência das técnicas de moldagem. Para o desajuste cervical, não houve diferença (p>0,05) para o dente 21. Para os dentes 14 e 16, apenas a técnica com casquetes individuais isolados apresentou diferença (p<0,05) em relação ao controle; enquanto para o dente 25 todas as técnicas com casquetes diferiram (p<0,05) do controle. Na mensuração da exatidão dimensional global, nenhuma técnica apresentou diferença (p>0,05) em relação ao controle. Para as mensurações áxio-cervicais do dente 25, todas as técnicas com casquete foram diferentes (p<0,05) do controle. Não houve diferença (p>0,05) nas dimensões do dente 21 e da distância interpreparos do segmento 14-16. De maneira geral, a técnica com casquetes isolados produziu modelos com maior desajuste marginal cervical. A forma de união dos casquetes, não apresentou influência sobre a exatidão dos modelos.
This study examined the accuracy of gypsum casts obtained from different impression techniques, including individual acrylic copings, and measured the cervical misfit of zirconia frameworks on dental preparations for fixed prosthodontics. A master cast with preparations in the teeth #14, 16, 21 and 25, on which zirconia frameworks were made by CAD/CAM technology, was used as control (baseline measurements). For each impression technique: single-step with condensation silicone (T1a), or vinyl polysiloxane (T1b); individual acrylic copings (T2); acrylic copings bonded with acrylic resin cylinders (T3) or metal cylinders (T4), 8 impressions were obtained by a single calibrated operator using stock trays. For the techniques T2, T3 and T4, polyether was used into the acrylic copings and condensation silicone was used for their pick-up. For the analysis of cervical marginal fit, zirconia frameworks were passively seated on the dental preparations of the gypsum casts, and measurements of cervical misfit calculated in stereo (50x). For the analysis of occlusal linear dimensional accuracy, the casts were scanned and, from three pre-defined points, side-to-side (LL) and bilateral anteroposterior (AP) measurements were performed by means of digitized images in the ImageJ software. Additionally, measurements of axio-cervical dimensions of each dental preparation and the distance between the preparations of the #14-16 fixed prosthodontics’ segment were taken with a digital caliper. Statistical analyzes (α=.05) were used to evaluate the influence of impression techniques. For cervical misfit, there was no difference (p>.05) for the tooth #21. For the teeth #14 and 16, only the technique T2 showed significant difference (p<.05) comparing to control; while for the tooth #25 all techniques with acrylic copings (T2, T3 and T4) differ (p<.05) from control. No significant differences were found among the techniques and the control (master cast) for the occlusal linear dimensions (p>.05). For axio-cervical measurements of tooth #25, all techniques using acrylic copings differ (p<.05) from control. There was no difference (p>.05) in the axio-cervical dimensions of tooth #21 and interpreparation distance of the #14-16 segment. In general, the technique with isolated acrylic copings (T2) produced casts with larger cervical misfit. The method for bonding the acrylic copings, by acrylic or metal cylinders, had no effect on the accuracy of the casts.
APA, Harvard, Vancouver, ISO, and other styles
18

Messias, Aion Mangino [UNESP]. "Influência de técnicas de moldagem e de dois vazamentos na precisão dimensional de modelos de gesso e adaptação marginal de infraestruturas CAD/CAM em Y-TZP." Universidade Estadual Paulista (UNESP), 2015. http://hdl.handle.net/11449/127807.

Full text
Abstract:
Made available in DSpace on 2015-09-17T15:25:44Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-03-18. Added 1 bitstream(s) on 2015-09-17T15:46:37Z : No. of bitstreams: 1 000846449.pdf: 793248 bytes, checksum: 4df424de74419794e88cc7fbcda6e98b (MD5)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Este estudo objetivou analisar a exatidão de modelos de gesso, a partir de diferentes técnicas de moldagem e segundos vazamentos de gesso, bem como mensurar o desajuste marginal de infraestruturas de zircônia sobre preparos dentais reproduzidos nesses modelos. Um modelo mestre, com preparos para coroa total nos dentes 14, 16, 21 e 25, foi obtido e infraestruturas em zircônia CAD/CAM foram confeccionadas. Moldes totais com moldeira de estoque e silicone de adição foram obtidos a partir de três técnicas de moldagem (n=15): T1) mistura simultânea; T2) reembasamento - alívio com filme de PVC e T3) reembasamento - alívio com movimentação da moldeira. Foram aguardados 120 min para o 1º. vazamento de gesso (Tipo IV). O 2º. vazamento foi realizado 120 min após a remoção dos primeiros modelos. Para a mensuração da adaptação marginal das infraestruturas utilizou-se estereomicroscópio LEICA (50x). Para a análise da precisão dimensional linear, os modelos foram fotografados e, a partir de pontos pré-definidos, mensurações oclusais lineares latero-laterais (LL) e anteroposteriores, direita (APD) e esquerda (APE), foram realizadas (ImageJ). Mensurações das dimensões mésio-distais (MD) e vestíbulo-linguais (VL) dos preparos e da distância interpreparos do segmento 14-16 foram realizadas. Após verificação da distribuição e da homocedasticidade dos dados, métodos estatísticos (α=0,05) foram empregados para avaliar a influência das variáveis independentes. De maneira geral, os modelos geraram maiores desajustes marginais em relação ao modelo mestre, independente do vazamento (1º ou 2º). Após 1º. vazamento, a técnica simultânea apresentou tendência a apresentar valores de desajuste menores do que as demais técnicas. Com exceção da dimensão MD do dente 21, a técnica simultânea produziu dimensões MD e VL similares ao modelo mestre. Não houve...(Resumo completo clicar acesso eletrônico abaixo)
This study conducted laboratory analysis of dental casts' accuracy obtained from different impression techniques and two castings, as well as measure the cervical marginal fit of zirconia infrastructures on dental preparations played in these models. Master model was used, with crown preparations in the teeth 14, 16, 21 and 25, on which zirconia infrastructures were made by CAD/CAM technology. For each impression technique full molds (n=15) were obtained by a single calibration operator with stock tray and polyvinylsiloxane: (T1) simultaneous mixture; (T2) reline - relief with PVC film and (T3) reline - relief with small movement of the tray. After mold removal, it was expected 120 min to realize the first pouring (type IV gypsum). The second pouring was made after 120 min from the removal of the first cast. To measure the marginal adaptation of infrastructure was used stereomicroscope LEICA (50x). For the analysis of linear dimensional accuracy, the models were photographed and, from pre-defined points, linear lateral-side occlusal measurements (LL) and anteroposterior, right (RPA) and left (EPA), were performed (ImageJ). Measurements of mesiodistal dimensions (MD) and bucco-lingual (VL) of the preparations and interpreparos distance segment 14-16 were performed. After verification of distribution and homocedasticity data, statistical methods (α = 0.05) were used to assess the influence of the independent variables. In general, larger models generated fringe displacement in relation to the master model, irrespective of the time of pouring (1º ou 2º). After 1st. pouring, the simultaneous technique tended to have lower misfit values than other techniques. Aside from tooth MD dimension 21 simultaneous technique produced dimensions MD and BL similar to the master model. No differences in inter-preparation linear dimensions and the occlusal line...(Complete abstract electronic access below)
APA, Harvard, Vancouver, ISO, and other styles
19

Messias, Aion Mangino. "Influência de técnicas de moldagem e de dois vazamentos na precisão dimensional de modelos de gesso e adaptação marginal de infraestruturas CAD/CAM em Y-TZP /." Araraquara, 2015. http://hdl.handle.net/11449/127807.

Full text
Abstract:
Orientador: José Maurício dos Santos Nunes
Banca: Francisco de Assis Mollo Júnior
Banca: Mauro Antonio de Arruda Nóbilo
Resumo: Este estudo objetivou analisar a exatidão de modelos de gesso, a partir de diferentes técnicas de moldagem e segundos vazamentos de gesso, bem como mensurar o desajuste marginal de infraestruturas de zircônia sobre preparos dentais reproduzidos nesses modelos. Um modelo mestre, com preparos para coroa total nos dentes 14, 16, 21 e 25, foi obtido e infraestruturas em zircônia CAD/CAM foram confeccionadas. Moldes totais com moldeira de estoque e silicone de adição foram obtidos a partir de três técnicas de moldagem (n=15): T1) mistura simultânea; T2) reembasamento - alívio com filme de PVC e T3) reembasamento - alívio com movimentação da moldeira. Foram aguardados 120 min para o 1º. vazamento de gesso (Tipo IV). O 2º. vazamento foi realizado 120 min após a remoção dos primeiros modelos. Para a mensuração da adaptação marginal das infraestruturas utilizou-se estereomicroscópio LEICA (50x). Para a análise da precisão dimensional linear, os modelos foram fotografados e, a partir de pontos pré-definidos, mensurações oclusais lineares latero-laterais (LL) e anteroposteriores, direita (APD) e esquerda (APE), foram realizadas (ImageJ). Mensurações das dimensões mésio-distais (MD) e vestíbulo-linguais (VL) dos preparos e da distância interpreparos do segmento 14-16 foram realizadas. Após verificação da distribuição e da homocedasticidade dos dados, métodos estatísticos (α=0,05) foram empregados para avaliar a influência das variáveis independentes. De maneira geral, os modelos geraram maiores desajustes marginais em relação ao modelo mestre, independente do vazamento (1º ou 2º). Após 1º. vazamento, a técnica simultânea apresentou tendência a apresentar valores de desajuste menores do que as demais técnicas. Com exceção da dimensão MD do dente 21, a técnica simultânea produziu dimensões MD e VL similares ao modelo mestre. Não houve...(Resumo completo clicar acesso eletrônico abaixo)
Abstract: This study conducted laboratory analysis of dental casts' accuracy obtained from different impression techniques and two castings, as well as measure the cervical marginal fit of zirconia infrastructures on dental preparations played in these models. Master model was used, with crown preparations in the teeth 14, 16, 21 and 25, on which zirconia infrastructures were made by CAD/CAM technology. For each impression technique full molds (n=15) were obtained by a single calibration operator with stock tray and polyvinylsiloxane: (T1) simultaneous mixture; (T2) reline - relief with PVC film and (T3) reline - relief with small movement of the tray. After mold removal, it was expected 120 min to realize the first pouring (type IV gypsum). The second pouring was made after 120 min from the removal of the first cast. To measure the marginal adaptation of infrastructure was used stereomicroscope LEICA (50x). For the analysis of linear dimensional accuracy, the models were photographed and, from pre-defined points, linear lateral-side occlusal measurements (LL) and anteroposterior, right (RPA) and left (EPA), were performed (ImageJ). Measurements of mesiodistal dimensions (MD) and bucco-lingual (VL) of the preparations and interpreparos distance segment 14-16 were performed. After verification of distribution and homocedasticity data, statistical methods (α = 0.05) were used to assess the influence of the independent variables. In general, larger models generated fringe displacement in relation to the master model, irrespective of the time of pouring (1º ou 2º). After 1st. pouring, the simultaneous technique tended to have lower misfit values than other techniques. Aside from tooth MD dimension 21 simultaneous technique produced dimensions MD and BL similar to the master model. No differences in inter-preparation linear dimensions and the occlusal line...(Complete abstract electronic access below)
Mestre
APA, Harvard, Vancouver, ISO, and other styles
20

Reis, José Ricardo Gonçalves. "Avaliação da eficácia do bochecho com solução de digluconato de clorexidina a 0,12% no controle dos microrganismos no processo de moldagem com hidrocoloide irreversível." Universidade Federal de Juiz de Fora (UFJF), 2011. https://repositorio.ufjf.br/jspui/handle/ufjf/3538.

Full text
Abstract:
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-03-03T14:35:40Z No. of bitstreams: 1 josericardogoncalvesreis.pdf: 2554419 bytes, checksum: 915d459831af949ef4a3cd5e0f9ab753 (MD5)
Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-03-06T20:16:12Z (GMT) No. of bitstreams: 1 josericardogoncalvesreis.pdf: 2554419 bytes, checksum: 915d459831af949ef4a3cd5e0f9ab753 (MD5)
Made available in DSpace on 2017-03-06T20:16:12Z (GMT). No. of bitstreams: 1 josericardogoncalvesreis.pdf: 2554419 bytes, checksum: 915d459831af949ef4a3cd5e0f9ab753 (MD5) Previous issue date: 2011-02-07
Avaliou-se a eficácia do bochecho com solução de digluconato de clorexidina a 0,12% no controle dos microrganismos no processo de moldagem com hidrocoloide irreversível. Foram selecionados 21 pacientes divididos em dois grupos: no G1 controle – realizou-se bochecho por 1min. com soro fisiológico e no G2 experimental – o bochecho por 1min. foi feito com solução de clorexidina a 0,12%, sendo colhidas salivas em três momentos experimentais: antes do bochecho, após o bochecho com as respectivas soluções e após a moldagem com hidrocoloide irreversível. As salivas coletadas foram semeadas pela técnica de esgotamento com alças calibradas estéreis de 1µL no meio de cultura CHROMagar Orientation® e deixadas em estufa com temperatura controlada em 37ºC por 24h. Os resultados foram avaliados pelo teste da Dupla Análise de Variância com nível de significância de 5% mostraram uma redução na contagem microbiana ao longo dos diferentes momentos experimentais nos dois grupos avaliados apresentando diferença estatisticamente significante (p < 0,001), sendo que no grupo experimental a redução de Streptococcus sp. e Staphylococcus sp. ou Neisseria sp. foi de 94% enquanto que no grupo controle foi de 25% para Staphylococcus sp. ou Neisseria sp. e 28% para Streptococcus sp. A antissepsia com a solução de clorexidina a 0,12% foi, comprovadamente, eficaz no controle da população microbiana da cavidade bucal, prevenindo a contaminação com altos níveis populacionais de cocos Gram-positivos e bastonetes Gram-negativos tanto na boca quanto nos moldes de hidrocoloide irreversível. Apesar dos resultados favoráveis encontrados, a indicação deste procedimento como protocolo clínico requer mais estudos sobre o uso em grupos de riscos, para investigação dos possíveis efeitos carcinogênicos da clorexidina, da formação de cepas resistentes, bem como no impacto ambiental causado pelo descarte deste material.
The effectiveness of rinsing with chlorhexidine gluconate solution at 0.12% was evaluated for the control of microorganisms in the molding process with irreversible hydrocolloid. There were twenty-one patients selected and divided into two groups: G1 control – rinsing was held for 1 minute with saline solution; and experimental G2 – rinsing was done for 1 minute with chlorhexidine at 0.12%, and saliva was sampled at three experimental moments: before the rinsing, after the rinsing with the respective solutions, and after molding with irreversible hydrocolloid. The saliva collected was seeded through the technique of exhaustion with sterile handles calibrated 1uL into the culture medium CHROMagar Orientation® and left in a greenhouse with controlled temperature at 37ºC for 24 hours. The results assessed by the Dual Analysis of Variance with a significance level of 5% showed a reduction in microbial counts throughout the different experimental moments in the two groups selected, presenting statistically significant difference (p < 0.001), and for the experimental group the reduction of Streptococcus sp. and Staphylococcus sp. or Neisseria sp. was 94% while for the control group was 25% for Staphylococcus sp. or Neisseria sp. and 28% for Streptococcus sp. The antisepsis with chlorhexidine at 0.12% was proven to be effective in controlling microbial population of the oral cavity, preventing contamination with high population levels of Gram-positive and Gram-negative as well as in the mouth along the lines of irreversible hydrocolloid. Despite the favorable results found, the indication of surgery and clinical protocol requires more studies on the use by risk groups for investigation of possible carcinogenic effects of chlorhexidine, the formation of resistant strains as well as the environmental impact caused by disposal of this material.
APA, Harvard, Vancouver, ISO, and other styles
21

Carlo, Hugo Lemes. "Influencia do conteudo volumetrico das particulas de cargas nas propriedades mecanicas de diferentes materiais de moldagem." [s.n.], 2008. http://repositorio.unicamp.br/jspui/handle/REPOSIP/288141.

Full text
Abstract:
Orientadores: Mario Alexandre Coelho Sinhoreti, Carlos Jose Soares
Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-11T16:18:48Z (GMT). No. of bitstreams: 1 Carlo_HugoLemes_D.pdf: 4484901 bytes, checksum: b6c246e6e05cdf7633210adfa7b73c84 (MD5) Previous issue date: 2008
Resumo: Baseado no entendimento incompleto de como o conteúdo de partículas de carga influencia nas propriedades mecânicas dos materiais de moldagem este estudo avaliou quantitativa e qualitativamente o conteúdo de partículas de carga inorgânicas presente em cinco marcas comerciais de alginatos (Jeltrate; Jeltrate Plus, Jeltrate Chromatic Ortho, Hydrogum e Ezact Krom) e nove marcas comerciais de siliconas de adição e/ou condensação nas consistências massa e/ou fluida (Clonage, Elite HD+ Light Body, Express Light Body, Flexitime, Optosil P Confort/Xantopren VL Plus, Oranwash L, Reprosil A+, Silon 2 APS e Virtual Extra Light Body). Foram realizados testes para determinar recuperação elástica e deformação sob compressão dos alginatos e dos elastômeros e estabelecer, dessa forma, uma correlação entre os resultados para partículas de carga e os testes mecânicos. O conteúdo volumétrico das partículas de carga foi determinado pesando-se as amostras submersas em água antes e após a queima das mesmas durante 3h a 450°C (alginatos) e a 600°C (siliconas). Quantidades determinadas de materiais não polimerizados foram lavadas em acetona e clorofórmio e recobertas com ouro para avaliação da morfologia e tamanho das partículas em M.E.V. A composição foi determinada por EDX. A recuperação elástica e a deformação sob compressão foram determinadas de acordo as especificações ? 1563 (alginatos) e 4823 (elastômeros) da ISO. O alginatos Jeltrate e Jeltrate Plus apresentaram os maiores valores médios para quantidade volumétrica de partículas de carga (%) enquanto o material Hydrogum apresentou os menores valores. A silicone de adição Flexitime Easy Putty apresentou os maiores valores de quantidade volumétrica de partículas, enquanto que a silicone de condensação Xantopren VL Plus apresentou os menores. As partículas de carga dos alginatos apresentaram-se, de forma geral, como objetos esféricos e com perfurações. O material Hydrogum apresentou forma de bastões cilíndricos e perfurados. As siliconas apresentaram morfologias variadas ¿ partículas trituradas, esféricas, esferóides, bastões cilíndricos perfurados e bastões misturados a partículas usinadas. O alginato Ezact Krom apresentou os maiores valores médios de tamanho de partícula, enquanto que o alginato Hydrogum as menores. A silicone de condensação Clonage massa apresentou os maiores valores médios de tamanho de partícula, enquanto a silicone de adição Elite HD os menores. A análise da composição das partículas apresentou o silício como o elemento em maior quantidade. Com relação aos resultados de recuperação elástica, o alginato Ezact Krom e as siliconas Reprosil A+ massa e Flexitime fluida apresentaram os maiores valores de recuperação elástica, enquanto o alginato Jeltrate Plus e as siliconas Optosil P Confort e Clonage fluida apresentaram os menores. Os resultados de deformação sob compressão foram maiores para o alginato Jeltrate Plus e para as siliconas Silon 2 APS massa e fluida. Os menores resultados foram apresentados pelo alginato Ezact Krom e as siliconas Reprosil A+ massa e Xantopren VL Plus. Todos os materiais estão em conformidade com a norma ISO ?1563, mas nem todos estão em relação à norma ?4823
Abstract: Based on the incomplete understanding on how filler features influence the properties of elastomeric impression materials, the purpose of this study was to determine the inorganic filler fraction and size of five commercially available alginates (Jeltrate; Jeltrate Plus, Jeltrate Chromatic Ortho, Hydrogum e Ezact Krom) and nine addition/condensation silicones using the putty/light consistence (Clonage, Elite HD+ Light Body, Express Light Body, Flexitime, Optosil P Confort/Xantopren VL Plus, Oranwash L, Reprosil A+, Silon 2 APS e Virtual Extra Light Body). A SEM/EDX analysis was done to qualitatively characterize the materials. Soon afterwards elastic recovery and strain in compression of the alginates and some the silicones was carried. The inorganic particles volumetric fractions were accessed by weighing a previously determined mass of each material in water before and after burning samples for 3 hours at 450ºC (alginates) and 600ºC (silicones). Unsettled materials were soaked in acetone and chloroform and sputter-coated with gold for SEM evaluation of fillers¿ morphology and size. The filler composition was determined by EDX. Elastic recovery and strain in compression tests were conducted according to ISO specification number 1563 and 4823. Jeltrate and Jeltrate Plus presented the highest mean values of percentage content of inorganic particles in volume, while Jeltrate Chromatic Ortho presented the lowest values. Flexitime Easy Putty was the silicone with the highest mean value, while Xantopren VL Plus had the lowest value. The alginate fillers presented a circular appearance with helical form and various perforations. Hydrogum fillers looked like cylindrical, perforated sticks. SEM pictures of the silicone inorganic particles showed numerous morphologies ¿ lathe-cut, spherical, spherical-like, sticks, and sticks mixed to lathe-cut powder. Ezact Krom was the alginate with the highest values for diameter size, while Hydrogum had the lowest. Clonage Putty showed the highest values, while Elite HD+ Light Body presented the lowest values. The component in higher concentration in the materials is silicon. The alginate Ezact Krom, and the addition cure silicones Reprosil A+ putty and Flexitime Correct Flow had the highest mean values of elastic recovery, while the alginate Jeltrate Plus and the condensation cured silicones Optosil P Confort and Clonage Putty presented the lowest values. Strain in compression test showed the alginate Jeltrate Plus and the condensation cured silicones Silon 2APS Putty and Fluid as the materials with the highest values. The alginate Ezact Krom and the silicones Reprosil A+ Putty and Xantopren VL Plus had lowest values. All materials are in conformity with the requirements of ISO specification number 1563, but not all materials are in conformity with the requirements of ISO specification number 4823
Doutorado
Materiais Dentarios
Doutor em Materiais Dentários
APA, Harvard, Vancouver, ISO, and other styles
22

Vega, Ruiz Malú Ingrid. "Comparación in vitro de los cambios dimensionales de modelos con yeso tipo IV en relación a la proporción polvo-líquido para la preparación del alginato." Bachelor's thesis, Universidad Peruana de Ciencias Aplicadas (UPC), 2014. http://hdl.handle.net/10757/325981.

Full text
Abstract:
La impresión dental es el procedimiento que más se realiza en la práctica clínica odontológica por lo que es indispensable realizarla de manera correcta para obtener un modelo definitivo óptimo. El propósito del presente estudio fue evaluar la alteración dimensional en modelos de yeso tipo IV obtenidos de impresiones con alginato, en las cuales la preparación empleó mayor o menor proporción de agua de lo que el fabricante refiere para la mezcla. El material utilizado fue alginato Tropicalgin de Zhermack®. Se realizó un modelo maestro de acero inoxidable, el cual simulaba una hemi-arcada con dos pilares. Se establecieron 3 grupos (Grupo1, Grupo control: 18 ml de agua y 9gr de polvo que corresponden a las proporciones indicadas por el fabricante, grupo 2: 13.5 ml de agua y 9 gr de polvo y grupo 3: 24 ml de agua y 9 gr de polvo). Se realizaron 15 impresiones por cada grupo que fueron vaciadas en yeso tipo IV Elite Rock de Zhermack®. Se realizaron 8 medidas a los modelos de yeso obtenidos de éstas impresiones mediante una máquina de medición por coordenadas con tecnología de Scanning por contacto modelo Contura G2 ZEISS para ser comparadas con las medidas del modelo maestro. Se hallaron diferencias estadísticamente significativas para las localizaciones E, F, G y H que corresponden a las medidas de las cimas y bases de los pilares.
Tesis
APA, Harvard, Vancouver, ISO, and other styles
23

Mariotto, Guilherme de Aguiar. "Pode a seleção da técnica ser superior ao material escolhido para a união de transferentes?" Universidade Estadual do Oeste do Paraná, 2018. http://tede.unioeste.br/handle/tede/4144.

Full text
Abstract:
Submitted by Edineia Teixeira (edineia.teixeira@unioeste.br) on 2019-03-12T21:59:27Z No. of bitstreams: 2 Guilherme_Mariotto_2018.pdf: 1557188 bytes, checksum: a9d67c335a6fbbe03d061239156c3baf (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Made available in DSpace on 2019-03-12T21:59:27Z (GMT). No. of bitstreams: 2 Guilherme_Mariotto_2018.pdf: 1557188 bytes, checksum: a9d67c335a6fbbe03d061239156c3baf (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2018-03-27
STATEMANT OF PROBLEM: The splint transfer technique in implant impression can result in misfit on prosthetic structures. PURPOSE: To evaluate the linear dimensional change of polymerization from 3 materials and 2 techniques of splint transfer technique for implant prostheses used in the open tray technique. MATERIAL AND METHODS: Two implants were installed in a nylon mastermodel whith the shape of a upperjaw, over this two implants, miruscone were tapered. Open tray transfer impression coppings were coupled in to the miruscone, and a silicone guide was made standardizing the unions between the transfers. The samples were divided in six groups (n=20): autopolymerizing acrylic resin Pattern Resin (PA) and Durallay (DU), and bis-acrylic resin Protemp4 (BI), with single step and sectioning and bonding segments techniques (PAC, DUC, BIC). The values of linear dimensional change between these transfers were measured in a profile projector (VB300; Starret) coupled to the Quadra Check apparatus, with a measurement capacity of 0.001 mm, performed by a calibrated single operator. Data were submitted to factorial ANOVA, two-way: Materials and technique (p <0.01) RESULTS: Statistically significant results were found in all comparisons. The PA resin presented the smallest values (μm) of linear dimensional change, both in the single-step technique and in the section and conding, in the following order: BI 255.73(+3.81), DU 173.75(+2.30), PA 95.97(+3.20), BIC 23.82(+1.71), DUC 20.85(+2.53), PAC 13.27(+2.09). The single-step technique obtained worse results regardless of the material. CONCLUSIONS: The sectioning and bonding technique reduced the dimensional change of the samples in all materials, and the Pattern Resin LS presented the lowest contraction, followed by Durallay and Protemp4. CLINICAL IMPLICATIONS: For the transfer splintage in implant prothesis the choice of technique seems to be more importante than the selection of the material to get fidelity of the models
DECLARAÇÃO DO PROBLEMA: A técnica de união entre os transferentes de moldagem para próteses sobre implantes pode resultar em desadaptações nas infraestruturas protéticas. OBJETIVOS: Avaliar a alteração dimensional linear de polimerização de 3 materiais e 2 técnicas de união de transferentes de moldagem para próteses sobre implantes utilizados na técnica da moldeira aberta. MATERIAL E MÉTODOS: Foi confeccionada uma matriz em forma de maxila em nylon, instalados dois implantes osseointegráveis e, sobre esses dois, minipilares cônicos retos. Transferentes de moldagem de moldeira aberta foram acoplados aos minipilares, e uma guia de silicone foi confeccionada padronizando as uniões entre transferentes. As amostras foram divididas em seis grupos (n=20): resinas acrílicas quimicoativadas Pattern Resin (PA) e Durallay (DU), e resina bisacrílica Protemp4 (BI), com as técnicas passo único e secção e união dos segmentos (PAC, DUC, BIC). Os valores de alteração dimensional linear ocorridos entre esses transferentes foram mensurados em projetor de perfil (VB300; Starret) acoplado ao aparelho Quadra Check, com capacidade de mensuração de 0.001 mm, realizado por único operador calibrado. Os dados foram submetidos ao teste de ANOVA fatorial, two-way: Materiais e técnica (p<0,01). RESULTADOS: Foram encontrados resultados estatisticamente significantes em todas as comparações. A resina PA apresentou os menores valores (μm) de alteração dimensional linear, tanto na técnica de passo único, quanto na técnica de secção e união, na seguinte ordem: BI 255.73(+3.81), DU 173.75(+2.30), PA 95.97(+3.20), BIC 23.82(+1.71), DUC 20.85(+2.53), PAC 13.27(+2.09). A técnica de passo único obteve piores resultados independente do material. CONCLUSÕES: A técnica de secção e união reduziu a alteração dimensional das amostras em todos os materiais, e a resina Pattern Resin LS apresentou a menor contração, seguida pela Durallay e Protemp4. IMPLICAÇÕES CLÍNICAS: Para a união de transferentes em próteses sobre implantes a escolha da técnica de união parece ser mais importante do que a seleção do material para a obtenção de maior fidelidade dos modelos.
APA, Harvard, Vancouver, ISO, and other styles
24

Silva, Stephania Caroline Rodolfo. "Influência de técnicas de moldagem com e sem casquetes na exatidão dimensional de modelos de gesso e adaptação marginal de infraestruturas em zircônia /." Araraquara, 2016. http://hdl.handle.net/11449/143095.

Full text
Abstract:
Orientador: José Maurício dos Santos Nunes Reis
Resumo: O presente estudo analisou a exatidão de modelos de gesso, obtidos a partir de diferentes técnicas de moldagem, incluindo casquetes individuais, isolados ou unidos, bem como mensurou o desajuste marginal cervical de infraestruturas de zircônia sobre preparos dentais para coroa total. Foi utilizado um modelo mestre (controle), com preparos nos dentes 14, 16, 21 e 25, sobre o qual infraestruturas de zircônia foram confeccionadas por tecnologia CAD/CAM. Para cada técnica de moldagem: simultânea com silicone de condensação (T1a), ou adição (T1b); casquetes individuais isolados (T2); unidos com cilindros de resina acrílica (T3); unidos com cilindros metálicos (T4); foram obtidos 8 moldes totais, por único operador calibrado, com moldeira de estoque. As moldagens com casquetes foram realizadas com poliéter e as transferências com silicone de condensação. Para a análise da adaptação marginal cervical das infraestruturas de zircônia, as mesmas foram passivamente adaptadas sobre os preparos nos modelos de gesso, sendo as mensurações do desajuste marginal cervical realizadas em estereomicroscópio (50x). Para a análise de exatidão dimensional linear oclusal global, os modelos foram escaneados e, a partir de três pontos pré-definidos, realizadas mensurações látero-laterais (LL) e anteroposteriores (AP) bilaterais do arco dental no programa ImageJ. Além disso, mensurações das dimensões áxio-cervicais de cada preparo e da distância entre os preparos do segmento 14-16 foram realizadas com p... (Resumo completo, clicar acesso eletrônico abaixo)
Abstract: This study examined the accuracy of gypsum casts obtained from different impression techniques, including individual acrylic copings, and measured the cervical misfit of zirconia frameworks on dental preparations for fixed prosthodontics. A master cast with preparations in the teeth #14, 16, 21 and 25, on which zirconia frameworks were made by CAD/CAM technology, was used as control (baseline measurements). For each impression technique: single-step with condensation silicone (T1a), or vinyl polysiloxane (T1b); individual acrylic copings (T2); acrylic copings bonded with acrylic resin cylinders (T3) or metal cylinders (T4), 8 impressions were obtained by a single calibrated operator using stock trays. For the techniques T2, T3 and T4, polyether was used into the acrylic copings and condensation silicone was used for their pick-up. For the analysis of cervical marginal fit, zirconia frameworks were passively seated on the dental preparations of the gypsum casts, and measurements of cervical misfit calculated in stereo (50x). For the analysis of occlusal linear dimensional accuracy, the casts were scanned and, from three pre-defined points, side-to-side (LL) and bilateral anteroposterior (AP) measurements were performed by means of digitized images in the ImageJ software. Additionally, measurements of axio-cervical dimensions of each dental preparation and the distance between the preparations of the #14-16 fixed prosthodontics' segment were taken with a digital caliper. Statis... (Complete abstract click electronic access below)
Mestre
APA, Harvard, Vancouver, ISO, and other styles
25

Lin, Maw-Shyong. "The viscometry of single-mix impression materials." 1986. http://books.google.com/books?id=KaE9AAAAMAAJ.

Full text
APA, Harvard, Vancouver, ISO, and other styles
26

SHIOU, CHING CHANG, and 張琇晴. "The comparision of the accuracy of dental impression materials." Thesis, 2002. http://ndltd.ncl.edu.tw/handle/30651078886002650751.

Full text
Abstract:
碩士
中山醫學大學
牙科材料研究所
90
The impressions for removable partial dentures should carry the ability to record the accuracy and detail of both the teeth and soft tissues. And the casts poured from the impressions should be the exact replicas of the oral structures to ensure the fit of RPD framework. The aim of this study is to analyze the accuracy and surface roughness of various impression materials and methods. The model is a full arch stainless steel master model with five cones represents the prepared abutments of the right first molar, right canine, right central incisor, left first premolar, and the left first molar on the maxillary. The materials used are additional silicone (Imprint II), irreversible hydrocolloids (AccuDent, Hydrogum, CA38 and Jeltrate), and reversible hydrocolloid Cohere 608). Stock (COE) or special ( Accu tray) is used and compared in certain circumstances. With or without adhesive for impressions are also examined and discussed. The distances between abutments of master model and poured casts are recorded and analyzed. The surface roughness of the poured casts for various impression materials is also registered in this study. The results show that there are statistically significant in dimensional change between master cast and any other poured casts from impression materials. Of those poured casts, the ones with additional silicone impression material show the highest accuracy, and the alginate impressions without adhesive on the trays show the poorest result. The poured casts from alginate impressions (either traditional alginates, eq. Hygrogum, CA38, and Jeltrate, or special formula alginate, eq. AccuDent) with adhesive on tray (either stock tray or special tray) end up with acceptable results. In surface quality results, the casts from additional silicone show the best result, followed by agar impression materials and alginate impression shows the worst result.
APA, Harvard, Vancouver, ISO, and other styles
27

Pratten, Don H. "Wettability and wetting behavior of elastomeric impression materials." 1987. http://books.google.com/books?id=S6w9AAAAMAAJ.

Full text
APA, Harvard, Vancouver, ISO, and other styles
28

Humphries, Robert M. "The accuracy of master casts fabricated from transfer impressions using the Branemark Osseointegrated Implant System a thesis submitted in partial fulfillment ... prosthodontics ... /." 1988. http://catalog.hathitrust.org/api/volumes/oclc/68788768.html.

Full text
APA, Harvard, Vancouver, ISO, and other styles
29

Taruvingira, A. K. "The compatibility of locally available alginate materials with gypsum materials." Thesis, 2014.

Find full text
Abstract:
Purpose: To assess and measure the compatibility of irreversible hydrocolloids (alginates) readily available in South Africa with available gypsum products by testing the quality reproducibility of lines on a standard die. Method: Under controlled laboratory conditions six brands of alginate impression material were tested against six types of gypsum products using the EN 21563:1991 (ISO 1563:1990) recommended protocol. Photomicrographs of the resultant gypsum surfaces were taken and a scoring method similar to that described by Owen (1986b) was used by previously calibrated independent examiners in order to evaluate the acceptable alginate/gypsum combinations. Results: There was an unexpected variability in the rater scores, and considerable variability in the quality of the casts from the various possible alginate/gypsum combinations. Statistical analysis allowed for the use of combination mean scores taking into account all the scores of all the raters, but discrimination was limited to those combinations with the best scores. The best possible score was 3 and the worst 12. In light of the inter-rater variability the combinations with scores of 4 or less were considered to be the recommended combination for clinical application. No alginate proved to be universally compatible with all the gypsum products tested and no gypsum product was universally compatible with all alginates. Conclusion: This study has highlighted the fact that not all alginates are compatible with all gypsum products, and that it is possible to find appropriate combinations for the clinical requirements of a dental cast. However, the fact that there were nine combinations which scored in the very worst category means that manufacturers of alginates should recommend specific gypsum products with which they are compatible and which were used to obtain their ISO rating, and clinicians should be more aware of the need for compatibility.
APA, Harvard, Vancouver, ISO, and other styles
30

Amorim, Ana Margarida da Costa. "Análise das técnicas e materiais de impressão em prótese total lecionados em programas de pós-graduação em protodontia." Master's thesis, 2016. http://hdl.handle.net/10400.14/22226.

Full text
Abstract:
Uma prótese dentária total removível é um dispositivo protético artificial que substitui toda a dentição e estruturas anexas da maxila ou da mandíbula. É consensual que para se obter uma prótese total removível bem-sucedida, é necessário ter-se suporte, estabilidade e retenção. Para isso, são vários os passos importantes na elaboração das próteses, desde uma impressão preliminar adequada que permita construir as moldeiras individuais, a realização de selamento periférico da moldeira individual e impressões definitivas com detalhe e precisão ótimos. Um selamento periférico e uma extensão da prótese total removível adequados ajudam a conseguir uma “tríade de equilíbrio”, caracterizada por boa retenção, suporte e estabilidade. O objetivo deste estudo foi identificar quais as tendências atuais nas impressões em prótese total realizadas nas pós-graduações em Prostodontia na Península Ibérica; determinar quais as técnicas de impressão mais utilizadas e determinar quais os biomateriais mais frequentemente usados, através de um questionário enviado por correio eletrónico aos responsáveis de pós-graduações no âmbito da Prostodontia na Península Ibérica. O questionário consistiu em 24 perguntas, divididas em duas partes. Apesar de ter havido limitações decorrentes da falta de algumas respostas a certas perguntas, que podem ter tido influência na possível inferência estatística dos resultados deste inquérito, foi possível verificar que: em grande parte, as técnicas e materiais utilizados são semelhantes entre Portugal e Espanha. No entanto, verificou-se que existem algumas diferenças, como por exemplo o tipo de moldeira utilizada nas impressões preliminares e o material utilizado para a realização da impressão definitiva. Não sendo conhecidos estudos deste tipo na Península Ibérica, verificou-se que a grande maioria das técnicas e materiais utilizados na Península Ibérica são semelhantes aos encontrados em pós-graduações na área de Prostodontia nos EUA.
A complete denture is an artificial prosthetic device that replaces the entire dentition and associated structures of the maxilla or the mandible. There exists consensus that to obtain a successful complete denture it is necessary to have support, stability and retention. It starts from an adequate preliminary impression, that allows building the individual trays, performing peripheral sealing of the individual tray to final impressions with great detail and accuracy. A peripheral sealing and an adequate extension of removable prostheses helps to acomplish a “triad of equilibrium” characterised by good retention, support and stability. The aim of this study was to identify the current trends in impressions for complete dentures made in post-graduate programs in Prosthodontics in the Iberian Peninsula; establishing the most used impression techniques as well as establishing which biomaterials are the most frequently used, through a survey sent by e-mail to postgraduate directors in Prosthodontics in Iberian Peninsula. This survey comprised 24 questions, divided into two parts. Although there have been limitations due to the lack of some answers to certain questions, which may have had an influence on the possible statistical inference of the results of this survey, it was found that: largely, the techniques and materials used were similar both in Portugal and Spain. Nevertheless, it was found that there are some differences, such as the type of tray used in the preliminary impression and the material used for final impressions. There aren’t any studies of this kind in the Iberian Peninsula and from the academic point of view it was found that most of the techniques and materials used in the Iberian Peninsula are similar to those found in the postgraduate prosthodontic programs in the United States of America.
APA, Harvard, Vancouver, ISO, and other styles
31

Sun, Ming. "A laboratory evaluation of detail reproduction, contact angle, and tear strength of three elastomeric impression materials." Thesis, 2011. http://hdl.handle.net/1805/2802.

Full text
Abstract:
Indiana University-Purdue University Indianapolis (IUPUI)
Fabrications of desirable fixed or removable dental prostheses depend upon accurate casts or dies. Recently, the most frequently used impression materials have been polyether (PE) and polyvinyl siloxane (PVS). However, both have their limitations: PVS is inherently hydrophobic, and PE is rigid. In order to take advantage of the desirable qualities of both PVS and PE impression materials, a new generation of impression material is being developed called vinyl polyether silicone (VPES, GC). The purpose of the present study was to compare the properties of hydrophilic PVS, PE, and VPES in regard to surface detail reproduction, contact angle, and tear strength. The hypotheses to be tested were: 1) VPES will show a significant superiority insurface detail reproduction compared with PVS and PE impression materials; 2) VPES will show a significant superiority in wettability compared with PVS and PE impression materials; 3) VPES will show a significant superiority in tear strength compared with PVS and PE impression materials. In order to test the surface detail reproduction, impressions were made of stainless steel dies with a parallel series of 15 different width lines on the surface and tested under dry and moist conditions. The wettability was assessed by contact angles of saturated CaSO4 aqueous solution drops on flat impression surfaces. A trouser tear test was employed to test the tear strength. The trouser-shaped specimens were prepared and tested in the Instron Universal Testing Machine. The data were analyzed by one-way ANOVA and Pearson‘s Chi square, (p < 0.05). All the materials showed better detail reproduction under the dry conditions than the moist conditions. There were no differences between the three materials in detail reproduction when impressing under either moist conditions or dry conditions. All the materials showed good wettability in the contact angle test. PVS rendered a contact angle as low as 34.19º. The contact angle of VPES was 44.84º, which was lower than 54.76º for PE. In the tear strength test, PE showed nearly two time higher tear strength than the other two impression materials. VPES showed slightly lower tear strength than PVS. The tear strength of the three materials tested in increasing order was VPES, PVS, PE. VPES showed comparable detail reproduction to PVS and PE and better wettability than PE, but showed the lowest tear strength compared with PE and PVS.
APA, Harvard, Vancouver, ISO, and other styles
32

Saker, Odie [Verfasser]. "Flow properties of dental impression materials by means of a modified sharkfin test at clinically relevant times after mixing / vorgelegt von Odie Saker." 2008. http://d-nb.info/988796333/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
33

Dhaliwal, Harpreet S. "Comparison of linear and injected impression material techniques to determine furcation volume of maxillary molars." 1997. http://catalog.hathitrust.org/api/volumes/oclc/48225663.html.

Full text
APA, Harvard, Vancouver, ISO, and other styles
34

Keesee, Patrick. "Comparison of linear and injected impression material techniques to determine furcation volume of mandibular molars." 1997. http://catalog.hathitrust.org/api/volumes/oclc/48225723.html.

Full text
APA, Harvard, Vancouver, ISO, and other styles
35

Marques, Marta Cristina Marinheiro. "Avaliar o comportamento e atitudes na desinfeção das impressões por parte de médicos dentistas e técnicos de laboratório de prótese : estudo piloto." Master's thesis, 2013. http://hdl.handle.net/10400.14/13780.

Full text
Abstract:
Objetivos: Verificar qual o nível de educação, conhecimento e importância que Médicos e Técnicos de Prótese têm sobre a temática da desinfeção de materiais de impressão e ainda avaliar se a comunicação entre estes inclui este assunto Materiais e Métodos: Efetuou-se um estudo observacional transversal segundo a técnica estratificada. A pesquisa abrangiu Médicos Dentistas (n=64) e Técnicos de Prótese Dentária (n=11) da região de Viseu, aos quais foi distribuído um questionário para a avaliação do comportamento e atitudes na desinfeção das impressões dentárias. Os resultados obtidos foram processados e analisados por métodos estatísticos descritivos. Resultados: O alginato é o material de impressão usado pela totalidade (100%) dos inquiridos e a Prostodontia é a área da Medicina Dentária que mais recorre aos materiais de impressão. 60,3% dos Médicos Dentistas afirma efetuar sempre a desinfeção dos materiais de impressão enviados para o Laboratório, no entanto 90,9% dos Técnicos não recebe qualquer notificação neste âmbito. A desinfeção química é feita maioritariamente com álcoois sob a forma de spray, sendo a eficácia o fator que mais influencia na escolha de um desinfetante. A maioria dos Médicos Dentistas questionados (65,6%) afirma não informar o Laboratório sobre o estado de desinfeção do biomaterial. 90,9% dos Técnicos de Prótese Dentária admita não confiar na desinfeção efetuada pelo Médicos Dentistas. Conclusões: As respostas obtidas indicam a necessidade de medidas educacionais adicionais no que concerne às práticas de controlo de infeção específica, bem como uma maior comunicação entre as clínicas e os laboratórios. No âmbito da comunicação e da confiança entre os Técnicos de Prótese Dentária e os Médicos Dentista, os resultados obtidos são abaixo do esperado e chegam mesmo a ser contraditórios com a literatura internacional.
Aims: To check the level of education, knowledge and significance that Dentists and Dental Technicians have on the subject of disinfection of impression materials, evaluating if communication between them covers this issue. Materials and Methods: A cross-sectional study using the stratified technique was performed. The research covered Dentists (n=64) and Dental Technicians (n=11) practicing in the Viseu region, to whom it was distributed a questionnaire to evaluate the behaviour and attitudes on dental impression disinfection. The results have been processed and analysed by descriptive statistical methods. Results: Alginate is the material used by all (100%) of the respondents and Prosthodontics is the Dentistry area that most uses this impression materials. 60.3% Dentists states always make disinfection of impressions materials that are sent to the Laboratory. However 90.9% of the Dental Technicians do not receive any notification about it. Chemical disinfection is performed with alcohols, mainly in the form of spray; effectiveness is the most determining factor when selecting the disinfection material. Most Dentists questioned (65.6%) declare not inform the Laboratory about the state of disinfection of the biomaterial. 90.9% of Dental Technicians admit not rely on disinfection performed by dentists. Conclusions: The responses indicate the need for additional educational measures regarding infection control practices and to improve communication between Dentists and Dental Technicians. Regarding communication and confidence, the results are lower than expected and even contradictory to the international literature.
APA, Harvard, Vancouver, ISO, and other styles
36

Alsayed, Hussain D. "Effect of interim fixed prosthodontics materials and flowable composite resins on polymerization of polyvinyl siloxane impressions." Thesis, 2017. https://doi.org/10.7912/C2QH2W.

Full text
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!

To the bibliography