To see the other types of publications on this topic, follow the link: Dentaport root ZX.

Journal articles on the topic 'Dentaport root ZX'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 17 journal articles for your research on the topic 'Dentaport root ZX.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse journal articles on a wide variety of disciplines and organise your bibliography correctly.

1

Yadav, Suman, Atul Gupta, Sumeet Sharma, and Sonal Soi. "The Evaluation of Three Electronic Apex Locators in Teeth with Simulated Horizontal Oblique Root Fractures." Journal of Oral Health and Community Dentistry 6, no. 2 (2012): 52–55. http://dx.doi.org/10.5005/johcd-6-2-52.

Full text
Abstract:
ABSTRACT Aim The accuracy of three electronic apex locators (EALs) to locate the apical limit in teeth with simulated horizontal oblique root fractures was investigated. Material and Methods A horizontal oblique incomplete root fracture was simulated on 30 freshly extracted maxillary anterior teeth by means of a notch made on the vestibular root plane 8 mm from the anatomic apex. The EALs investigated were the ProPex II (Dentsply Maillefer, Ballaigues, Switzerland), the Mini Apex Locator (Sybron Endo, Orange CA), and the Dentaport ZX (J. Morita Corp, Kyoto, Japan). The electronic measurements
APA, Harvard, Vancouver, ISO, and other styles
2

Tufenkci, Pelin, and Aylin Kalaycı. "Evaluation of the accuracy of different apex locators in determiningthe working length during root canal retreatment." Journal of Dental Research, Dental Clinics, Dental Prospects 14, no. 2 (2020): 125–29. http://dx.doi.org/10.34172/joddd.2020.026.

Full text
Abstract:
Background. This study aimed to assess the accuracy of three electronic apex locators (EALs) (DentaportZX [J Morita, Tokyo, Japan], Propex Pixi [Dentsply Maillefer, Ballaigues, Switzerland], and iPex II [NSK,Tokyo, Japan]) during root canal retreatment. Methods. The root canal lengths of 90 extracted single-rooted human teeth were determined under adental operating microscope at ×10 magnification. The actual working length (AWL) was 0.5 mm lessthan the root length. Electronic measurements were performed with the three EALs. The root canalswere instrumented and filled to the actual working leng
APA, Harvard, Vancouver, ISO, and other styles
3

Sunil, Tejaswi, Ayyagari Viresh G, Singh Ankita, Shetty Suneeth, K. Ambikathanaya U, and B. Manglekar Sachin. "To Evaluate the Accuracy Between Two Different Electronic Apex Locators to Detect the Root Canal Perforation During Retreatment - An Ex-Vivo Study." Indian Journal of Science and Technology 15, no. 42 (2022): 2259–66. https://doi.org/10.17485/IJST/v15i42.1582.

Full text
Abstract:
Abstract <strong>Objectives:</strong>&nbsp;To evaluate the accuracy between two different electronic apex locators in detecting the root canal perforation in the middle and apical portion during retreatment.&nbsp;<strong>Methods:</strong>&nbsp;Sixty freshly extracted mandibular premolars were taken in to this study, which were divided into three groups of twenty each. Group I: Control Group, Group II: Positive control without perforation, Group III: Negative control with perforation. In all the groups, access cavity preparation was done followed by cleaning and shaping using X smart Endomotor
APA, Harvard, Vancouver, ISO, and other styles
4

Shantanu, Choudhari R., Saxena Sandip, and Vaghela Parikrama Solanki Chirag. "Comparative Evaluation of Root Length Values Determined by Two Different Types Of Electronic Apex Locators And Paralleling Radiographic Method In Primary Mandibular Second Molars Of Children Of 5 To 7 Years Age Group." British Journal of Pharmaceutical and Medical Research 2, no. 5 (2017): 753–58. https://doi.org/10.24942/bjpmr.2017.153.

Full text
Abstract:
Material &amp; Methods: A study was carried out on 150 root canals from 50 children in primary second molars indicated for pulpectomy in children of age 5-7 years attending Department of Pedodontics, Government Dental College &amp; Hospital, Ahmedabad. The standard procedure for pulpectomy was carried out and the root canal length was clinically measured with the help of electronic apex locator&nbsp; (Propex II &amp; DentaPort ZX ) and paralleling radiographic method. The values were subjected to one-way ANOVA test. Results: In the current study, mean canal length by Propex II apex locator was
APA, Harvard, Vancouver, ISO, and other styles
5

Tracchegiani, Leonardo, Stefan Manea, Claudia Valentina Lungu, Sinziana Adina Scarlatescu, Paula Perlea, and Anna Maria Pangica. "Comparative ”ex vivo” study on working length determination using six apex locators." Romanian Journal of Stomatology 69, no. 1 (2023): 5–7. http://dx.doi.org/10.37897/rjs.2023.1.1.

Full text
Abstract:
The aim of this study was to analyze the accuracy, precision, and consequently the reliability of five traditional apex locators (AL) and one integrated AL in determining working length (WL). Materials and Methods: The lengths of 15 extracted human teeth were measured with six ALs (Dentaport Root ZX, Dual Pex Micro Mega, Root ZX mini, Elements Diagnostic, Woodpex III, and E-connect S) and with digital radiographs (RVG). Electronic measurements were compared with each other and with radiographic measurements under the same experimental conditions. Results: Repeated measures ANOVA showed a signi
APA, Harvard, Vancouver, ISO, and other styles
6

Puri, Nikhil, Rupali Chadha, Pragya Kumar, and Komal Puri. "An in vitro comparison of root canal length determination by DentaPort ZX and iPex apex locators." Journal of Conservative Dentistry 16, no. 6 (2013): 555. http://dx.doi.org/10.4103/0972-0707.120953.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Ebrahim, AK, R. Wadachi, and H. Suda. "An in vitro evaluation of the accuracy of Dentaport ZX apex locator in enlarged root canals." Australian Dental Journal 52, no. 3 (2007): 193–97. http://dx.doi.org/10.1111/j.1834-7819.2007.tb00488.x.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Cimilli, Hale, Seda Aydemir, Burcin Arıcan, Gonca Mumcu, Nicholas Chandler, and Nevin Kartal. "Accuracy of the Dentaport ZX apex locator for working length determination when retreating molar root canals." Australian Endodontic Journal 40, no. 1 (2012): 2–5. http://dx.doi.org/10.1111/aej.12010.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Altenburger, M. J., J. P. Tchorz, and Francesco Somma. "In Vivoaccuracy of three electronic root canal length measurement devices: Dentaport ZX, Raypex 5 and ProPex II." International Endodontic Journal 45, no. 11 (2012): 1053–54. http://dx.doi.org/10.1111/j.1365-2591.2012.02060.x.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Somma, F., R. Castagnola, C. Lajolo, L. Paternò Holtzman, and L. Marigo. "In vivo accuracy of three electronic root canal length measurement devices: Dentaport ZX, Raypex 5 and ProPex II." International Endodontic Journal 45, no. 6 (2012): 552–56. http://dx.doi.org/10.1111/j.1365-2591.2011.02010.x.

Full text
APA, Harvard, Vancouver, ISO, and other styles
11

LNU, Alexander, Musab Hamed Saeed, Nazil A. Abtahl, and A. Praveen Pradeep. "An in vitro Comparison of Root Canal Measurement in Permanent Teeth by Electronic Apex Locator, Conventional and Digital Radiography." World Journal of Dentistry 2, no. 4 (2011): 312–15. http://dx.doi.org/10.5005/jp-journals-10015-1104.

Full text
Abstract:
ABSTRACT Introduction In endodontic treatment for permanent teeth, it is important to estimate the working length precisely. Currently, various methods are used in clinical practice for working length estimation. The objective of this study is to compare the accuracy of root canal length in permanent teeth determined by electronic apex locators, conventional and digital radiography. Materials and methods A total of 50 single rooted permanent teeth with mature apices were extracted for periodontal reasons and obtained from different sources without caries were studied. The radiographic measurem
APA, Harvard, Vancouver, ISO, and other styles
12

Koç, Simay, Hatice Harorlı, and Alper Kuştarcı. "In-vitro Evaluation of the Accuracy of Electronic Apex Locators and Cone Beam Computed Tomography in the Detection of Oblique Root Fractures." Dentomaxillofacial Radiology, July 22, 2024. http://dx.doi.org/10.1093/dmfr/twae037.

Full text
Abstract:
Abstract Objectives This study aimed to compare the accuracy of cone-beam computed tomography (CBCT) scanning and three different electronic apex locators (EALs) in the detection of simulated oblique root fractures (ORF) in different localizations. Methods The study utilized a total of eighty human maxillary incisors, which were categorized into two groups based on the location of the ORF (apical and middle third of the root) formed on the buccal side of the root surface. The measurement of the distance between the incisal edge and the intersection of the ORF with the root canal was conducted
APA, Harvard, Vancouver, ISO, and other styles
13

"Noch komfortabler - Das optimierte DentaPort Root ZX-Modul." ZWR - Das Deutsche Zahnärzteblatt 114, no. 07/08 (2005): 360. http://dx.doi.org/10.1055/s-2005-872389.

Full text
APA, Harvard, Vancouver, ISO, and other styles
14

Çakmak, Yunus Emre, Damla Erkal, Hatice Harorlı, and Simay Koç. "Evaluation of the Accuracy of an Endomotor-Integrated Apex Locator Versus a Standalone Electronic Apex Locator in Teeth with Simulated Apical Root Resorption: An In Vitro Study." European Journal of Therapeutics, June 20, 2025. https://doi.org/10.58600/eurjther2693.

Full text
Abstract:
Objective: This in vitro study aimed to evaluate and compare the accuracy of an endomotor-integrated apex locator system and a conventional electronic apex locator in determining the working length (WL) of root canals with simulated apical root resorption, in both straight and curved canal anatomies. Methods: Sixty-seven extracted mandibular molars with either straight distal canals or curved mesiobuccal canals were included. Simulated external apical resorption was created using a standardized protocol. Actual working length was determined under a stereomicroscope. WL was then measured using
APA, Harvard, Vancouver, ISO, and other styles
15

"J. Morita - Fünf Sterne für das DentaPort Root ZX." ZWR - Das Deutsche Zahnärzteblatt 115, no. 12 (2006): 584. http://dx.doi.org/10.1055/s-2006-957015.

Full text
APA, Harvard, Vancouver, ISO, and other styles
16

ALTUNBAŞ, Demet, Kerem Engin AKPINAR, and Fatma KAYA. "Kök Uçları Farklı Açılarda Rezeke Edilmiş Dişlerin Cerrahi Olmayan Yeniden Tedavilerinde 3 Elektronik Apeks Bulucunun Doğruluğu: In-Vitro Çalışma." Cumhuriyet Dental Journal, June 7, 2022. http://dx.doi.org/10.7126/cumudj.1103606.

Full text
Abstract:
Aim: The accuracy of three electronic apex locators (EALs) during retreatment of root-end resected teeth with different resection bevel angles were evaluated in the present study. &#x0D; Materials and Methods: Forty mandibular premolar teeth were divided into two groups regarding resection bevel angle after root canal filling. In the first group, the apical 3 mm of each specimen was resected at a 0-degree bevel angle using a diamond bur. The resection bevel angle was approximately 45-degree in the second group. Electronic length measurements were obtained with a size 15 K-file advanced apicall
APA, Harvard, Vancouver, ISO, and other styles
17

MATTIGATTI, SUDHA B., VAISHALI MASHALKAR, and HARSH RAMESH PATWARDHAN. "AN In-vitro EVALUATION OF ACCURACY OF THREE ELECTRONIC APEX LOCATORS IN THE PRESENCE OF 3% SODIUM HYPOCHLORITE." UTTAR PRADESH JOURNAL OF ZOOLOGY, December 30, 2021, 1299–304. http://dx.doi.org/10.56557/upjoz/2021/v42i243251.

Full text
Abstract:
The condition known as the variation of the apical foramen and asymmetrical root canal opening is identified when the main foramen of the root canal is not situated at the anatomical apex. Under these conditions, it is possible to determine the working length incorrectly, which might result in many issues that could compromise the effectiveness of the endodontic procedure. In this work, we examined the apical foramen detection accuracies of these three EALs in 3% sodium hypochlorite (NaClO).&#x0D; Materials and Procedures: To clean the teeth and remove organic material stuck to the exterior ro
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!