Academic literature on the topic 'Descarga parcial'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Descarga parcial.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "Descarga parcial"

1

Leite, Reinaldo Corrêa. "Quantificação de descargas parciais em geradores usando modelo matemático baseado na teoria de campo." Revista Principia - Divulgação Científica e Tecnológica do IFPB 1, no. 56 (September 13, 2021): 248. http://dx.doi.org/10.18265/1517-0306a2021id4824.

Full text
Abstract:
<p class="Normal1"><span>Este trabalho desenvolve um modelo para quantificar o nível de descargas parciais (DP) em cavidades ocluídas em sistemas de isolação de geradores. O modelo baseia-se na teoria de campo e usa o Método dos Elementos Finitos (MEF) para resolver as equações de campo. A simulação desenvolve-se em dois passos: no primeiro passo simula-se a situação anterior à descarga parcial, em que não existem cargas espaciais no interior da cavidade, pela resolução das equações de Laplace. Já o segundo passo simula a situação logo após a ocorrência da DP, resolvendo-se as equações de Poisson, simulando a existência das cargas espaciais criadas durante o tempo de descarga. As simulações indicam uma diferença de 2,14% entre os níveis de DP medido e calculado para uma delaminação na isolação de uma barra estatórica. Com base nesse resultado, o modelo é capaz de estimar o nível de DP para defeitos localizados no sistema de isolação de estatores de hidrogeradores.</span></p>
APA, Harvard, Vancouver, ISO, and other styles
2

Andrade, Daniela Oliveira de. "Padrão eletrográfico ictal subclínico em um caso de epilepsia parcial benigna da infância com pontas centro-temporais." Arquivos de Neuro-Psiquiatria 63, no. 2a (June 2005): 360–63. http://dx.doi.org/10.1590/s0004-282x2005000200033.

Full text
Abstract:
Há poucos relatos na literatura do padrão ictal na epilepsia parcial benigna da Infância com pontas Centrotemporais (EPCT). Esse trabalho descreve o caso de um menino, de 7 anos, sem antecedentes de sofrimento neonatal ou distúrbio do desenvolvimento neuropsicomotor, com de história familiar de epilepsia. A ressonância magnética do encéfalo foi normal. O paciente apresentou uma única crise durante sono, seguida de breve déficit motor membro superior esquerdo. O EEG dois dias após a crise evidenciou atividade de base normal com pontas centro-temporais bilaterais, e duas descargas subclínicas de ponta-onda rítmicas, de duração superior a 50 segundos em região centro-temporal direita. Este padrão de descarga rítmica não foi descrito na EPCT anteriormente.
APA, Harvard, Vancouver, ISO, and other styles
3

Urso, Gabriela Oliveira. "Abordagem fisioterapêutica em diferentes tipos de artroplastia de quadril." Fisioterapia Brasil 11, no. 1 (November 14, 2017): 49. http://dx.doi.org/10.33233/fb.v11i1.1332.

Full text
Abstract:
Introdução: Artroplastia de quadril (AQ) é uma técnica que realiza a substituição total ou parcial da articulação do quadril por prótese cimentada e não cimentada. Existem diferentes protocolos de reabilitação no pré e pós-operatório que englobam a marcha, descarga de peso e cinesioterapia. O objetivo deste estudo foi realizar uma revisão da literatura sobre a abordagem fisioterapêutica nos diferentes tipos de AQ. Método: Foi realizada uma revisão bibliográfica compreendida entre o ano de 1993 a 2008, pesquisada no período de agosto de 2008 a abril de 2009, nas bases de dados PubMed, Cochrane, Medline, Lilacs e Scielo. Conclusão: Foi possível observar que a AQ não cimentada apresenta bons resultados e menor incidência de complicações. Os protocolos fisioterapêuticos não entram em um consenso em relação ao tempo exato para a execução dos mesmos, porém podemos afirmar que a fisioterapia é essencial no pré e pós-operatório. É necessário que haja mais estudos relacionados a protocolos específicos que abordem a fisioterapia em diferentes tipos de protetização.Palavras-chave: artroplastia total de quadril, artroplastia parcial de quadril, fisioterapia, reabilitação.
APA, Harvard, Vancouver, ISO, and other styles
4

Muszkat, Mauro, Neyde Santacchi de Vincenzo, Alice Masuko, Denilce O. Reami, and Carlos J. Reis de Campos. "Análise da assimetria funcional hemisférica de crianças com epilepsia parcial e QI normal pelo desempenho nos subtestes do WISC." Arquivos de Neuro-Psiquiatria 49, no. 4 (December 1991): 392–98. http://dx.doi.org/10.1590/s0004-282x1991000400004.

Full text
Abstract:
Foram avaliadas 26 crianças, sem deficiência mental, com média de idade de 9±2 anos, com epilepsia parcial sem lesão cerebral evidenciável à TCC e com atividade paroxistica no EEG intercrítico localizada apenas em um hemisfério cerebral. Essas crianças foram submetidas à Escala de Inteligência Wechsler para Crianças (WISC) e à análise dos vários subtestes verbais e execução em relação à localização hemisférica da descarga no EEG. Os dados foram comparados ao desempenho no WISC de um grupo de 61 crianças sem epilepsia na mesma faixa etária (Grupo Controle). As crianças epilépticas apresentaram desempenho inferior no QI execução, em três subtestes verbais (Informação, Dígitos e Aritmética) e em três subtestes execução (Cubos, Armar Objetos e Código). Os pacientes com foco eletrencefalográfico no hemisfério direito apresentaram desempenho inferior ao Grupo Controle nos subtestes relacionados à habilidade espacial e atenção não-verbal (Cubos, Armar Objetos e Código), enquanto as crianças com foco no hemisfério esquerdo apresentaram desempenho inferior apenas no subteste de Dígitos (relacionado à memória imediata e atenção verbal). Os autores sugerem que a localização hemisférica do foco no EEG intercrítico tem relação com o tipo de déficit cognitivo associado à epilepsia parcial não-lesional, mesmo em crianças com QI normal.
APA, Harvard, Vancouver, ISO, and other styles
5

Sella, Valéria R. G., Paula C. D. Machado, Hélio J. A. Fernandes, William R. Limonge, Fernando B. Reis, and Flávio Faloppa. "A visão do ortopedista brasileiro sobre a descarga parcial de peso em ortostase nas fraturas expostas da diáfise da tíbia após osteossíntese." Revista Brasileira de Fisioterapia 13, no. 6 (December 2009): 514–20. http://dx.doi.org/10.1590/s1413-35552009000600008.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Dutra, Cynthia Maria Rocha, Ericson Pereira, João Egdoberto Siqueira, Marciane Maria Kulczyki, Luis Roberto Aguiar, and Elisangela Ferreti Manffra. "Densidade mineral óssea de pessoas com lesão medular após seis meses de treino locomotor com suporte parcial de peso." Fisioterapia em Movimento 25, no. 3 (September 2012): 489–95. http://dx.doi.org/10.1590/s0103-51502012000300004.

Full text
Abstract:
INTRODUÇÃO: O treino locomotor com suporte parcial de peso (TLSP) pode ser aplicado na reabilitação de pessoas com lesão medular e proporcionar melhoras funcionais, da função cardiovascular e auxiliar na prevenção e tratamento da osteopenia e osteoporose, que são importantes complicações secundárias à LM. OBJETIVOS: Este estudo teve como objetivo determinar e comparar a densidade mineral óssea (DMO) antes e após seis meses de TLSP em sujeitos com LM incompleta. MÉTODO: A amostra foi composta por oito voluntários, com LM com classificações (ASIA) A, B e D. O grupo foi submetido a sessões de treinos, três vezes por semana, com duração de 15 minutos, a uma velocidade de 1,5 km/h. A descarga de peso sobre membros inferiores era aumentada em 5% do peso corporal a cada duas semanas, passando de 20% até 65% do peso corporal, desde o início até o fim do período. Foram realizados exames de densitometria óssea antes do início e logo após o encerramento do programa de treinamento. RESULTADOS: Houve aumento na DMO média do fêmur total que, apesar de pequeno (0,05 g/cm²), foi significativo (p = 0,034). Nas demais regiões (colo do fêmur e trocânter) não houve alteração significativa. CONCLUSÃO: O TLSP pode ter auxiliado na manutenção da DMO nas regiões do colo do fêmur e trocânter.
APA, Harvard, Vancouver, ISO, and other styles
7

Rodríguez Gutierrez, Washington. "Estudio del eje hipotalamo-hipofisis-ovario, en la hemorragia uterina disfuncional." Revista Peruana de Ginecología y Obstetricia 21, no. 1-2-3 (July 18, 2015): 104–11. http://dx.doi.org/10.31403/rpgo.v21i1448.

Full text
Abstract:
Se ha estudiado la interrelación de hipotálamo-hipófisis y ovario durante tres meses, en tres casos de mujeres jóvenes con hemorragia uterina disfuncional, mediante determinaciones radioinmunológicas seriados en plasma de FSH, LH, estradiol y progesterona. En 2 de las pacientes se observaron ciclos a novulatorios, incluso después de administrar citrato de clomifeno, presentándose falla al menos parcial, en la descarga de LH como respuesta a los marcados incrementos, aunque irregulares, del estradiol, procedente de secreción folicular adicional. En un caso se presentó probable ciclo ovulatorio espontáneo y después inducido por clomifeno. A su vez, las elevaciones plasmáticas de LH y FSH, encontradas durante el tratamiento con el clomifeno y subsiguiente desarrollo folicular, indicarían que se mantuvo indemne el mecanismo del feedback negativo entre el estrógeno y las gonadotrofinas. A juzgar por estos hallazgos, pareciera que hay cambios en la sensibilidad del hipotálamo, de ciclo a ciclo, en la hemorragia uterina disfuncional de la adolescencia.
APA, Harvard, Vancouver, ISO, and other styles
8

Nogueira, Guilherme Emidio Horta, and Chang Hung Kiang. "Simulação numérica de fluxo de águas subterrâneas do aquífero rio claro, porção nordeste do município de Rio Claro, SP." Águas Subterrâneas 29, no. 2 (August 10, 2015): 175. http://dx.doi.org/10.14295/ras.v29i2.28304.

Full text
Abstract:
<p>No campus da UNESP em Rio Claro, SP, o abastecimento hídrico provém unicamente do aquífero local, constituído por sedimentos cenozoicos areno-siltosos da Formação Rio Claro. O principal objetivo deste trabalho foi a ampliação do entendimento do Aquífero Rio Claro, por meio da revisão do modelo conceitual e construção de modelo numérico de fluxo, utilizando o Método de Elementos Finitos como solução. Os resultados obtidos com as simulações em regime permanente e transiente mostram que a heterogeneidade litológica e hídrica da unidade aquífera resulta em baixo armazenamento específico médio; evidenciam também que as drenagens funcionam como zonas de descarga, e o território do câmpus e circunvizinhanças como área de recarga. A condutividade hidráulica varia entre 10<sup>-6</sup> m/s e 10<sup>-4</sup> m/s, e a razão recarga/precipitação foi estimada em 13%. Para uma hipotética duplicação na taxa de explotação dos poços, bem como para a supressão parcial ou total da recarga, notou-se grande alteração na sensibilidade do modelo e grande impacto no aquífero.</p>
APA, Harvard, Vancouver, ISO, and other styles
9

Dombrovski, Liliane, Rosiane Maira Kuester, Priscila Batista da Rosa, Caio Cesar Sestile, Adrielli Tenfen, and Vivian Binder Neis. "Avaliação do perfil de consumo, armazenamento e descarte de medicamentos por indivíduos que frequentam farmácias privadas em Jaraguá do Sul - SC." Research, Society and Development 10, no. 9 (July 22, 2021): e13210917917. http://dx.doi.org/10.33448/rsd-v10i9.17917.

Full text
Abstract:
O avanço da tecnologia farmacêutica proporcionou um aumento na fabricação de medicamentos, o que tem contribuído para o aumento da automedicação e descarte inadequado. Este estudo teve como objetivo avaliar a automedicação, armazenamento e descarte de medicamentos em pacientes de farmácias privadas de Jaraguá do Sul, SC. Para isto, aplicou-se um questionário com clientes que frequentam farmácias privadas do município. O questionário possuía 32 perguntas, divididas em 4 etapas: dados sociodemográficos, prevalência de automedicação e o perfil de consumo de medicamentos, conhecimento sobre armazenamento, validade e integridade dos medicamentos e o conhecimento sobre o descarte correto e o impacto causado ao meio ambiente. Com os resultados obtidos de 120 pacientes, foi possível observar que 91,7% deles se automedicam. Além disso, observou-se que 65% nunca receberam orientações sobre como descartar os medicamentos vencidos ou em desuso. Por isso, 58% dos entrevistados descartam de forma inadequada, e estudos evidenciam que quando em contato com o solo e a água, esses medicamentos podem causar contaminação, que mesmo em uma rede de tratamento de esgoto não é eliminada completamente. É um problema pouco divulgado, porém com consequências catastróficas. Com os resultados do presente estudo, conclui-se que a população tem sua parcela de responsabilidade também devendo estar esclarecida e envolvida no processo de conscientização do uso, armazenamento e da geração de resíduos derivados dos medicamentos, reforçando a necessidade de estratégias de educação sobre o tema.
APA, Harvard, Vancouver, ISO, and other styles
10

Gimenes, Pollyanna Santos, and Eliane Sebeika Rapchan. "DESCARTE DE ÓLEO DE COZINHA NO MUNICIPIO DE FORMOSA DO OESTE: DIAGNÓSTICO E EDUCAÇÃO AMBIENTAL EM ENSINO FUNDAMENTAL." Revista Valore 3, no. 1 (June 14, 2018): 446–53. http://dx.doi.org/10.22408/reva312018106446-453.

Full text
Abstract:
A produção de soja é a principal cultura da agricultura brasileira, é realizada em grande escala, fazendo do Brasil o segundo maior produtor do mundo. O óleo de soja é largamente utilizado pelos brasileiros, entretanto o descarte incorreto pode trazer danos econômicos, além de danos ambientais como a contaminação de solo e água. O objetivo deste artigo é diagnosticar a forma de descarte do óleo de cozinha no município de Formosa do Oeste, Paraná, a fim de fornecer subsídios para a elaboração de um programa municipal de reciclagem de óleo. Para isso, um questionário com sete perguntas objetivas, foi aplicado às famílias de 62 alunos do 4ºano de uma escola de ensino fundamental. Posteriormente, os dados foram colocados em gráficos e analisados. Os resultados mostram que, embora a população pesquisada tenha apresentado índices baixos (35%) de reciclagem do produto e índices moderadamente altos (65%) de descarte incorreto, a maioria tem interesse tanto em reciclar (95%), e doar produto (90%). Embora os estudos precisem abordar uma parcela maior da população para serem mais conclusivos, pode-se inferir que a população descarta o óleo de maneira incorreta, mas possui interesse em realizar a disposição do resíduo no ambiente de forma correta e segura.
APA, Harvard, Vancouver, ISO, and other styles
More sources

Dissertations / Theses on the topic "Descarga parcial"

1

Bacega, Felippe. "Avaliação do estado dos equipamentos do sistema de transporte de energia elétrica através de técnicas de medição de descargas parciais em campo." Universidade de São Paulo, 2014. http://www.teses.usp.br/teses/disponiveis/106/106131/tde-05112014-150019/.

Full text
Abstract:
Neste trabalho é apresentado um novo método de medição de descargas parciais, através de transformadores de corrente de alta frequência, instalados no condutor de aterramento dos equipamentos do sistema elétrico de potência e acoplados a um osciloscópio. Esse novo método de medição tem como grande ganho o fato dos equipamentos não precisarem ser retirados de operação para realização de medição. Pelo fato das transmissoras serem remuneradas pela disponibilidade das funções transmissão, o diagnóstico dos equipamentos em serviço faz com que os custos sejam reduzidos. Foi realizado um levantamento teórico onde foi definida a curva característica esperada como resposta do transformador de corrente a um sinal impulsivo. Foram levantadas curvas características, em laboratório, através de oscilogramas no domínio do tempo, das assinaturas de descargas parciais em equipamentos com isolação a óleo e a gás SF6, de modo a validar o sinal esperado na fundamentação teórica. Essas assinaturas foram utilizadas em medições em campo, que comprovaram a viabilidade da fundamentação teórica e das assinaturas obtidas em laboratório. Adicionalmente foram levantados fatores que podem influenciar nas medições e mostrados sinais que possuam características diferentes daquelas das descargas parciais, de modo a diferencia-los.
This work presents a new method of measuring partial discharges, through high frequency current transformers, installed in the equipment grounding conductor of the electrical power system and coupled to an oscilloscope. This new measurement method has as great gain, the fact that the equipment doesnt need to be removed from service to perform measurement. Because of the transmission being remunerated by the availability of the transmission functions, diagnosis of equipment in service makes the costs been reduced. A theoretical survey where the characteristic curve expected response from the current transformer to an impulsive signal was set has been done. Characteristic curves were raised in the laboratory through oscillograms in the time domain, of signatures of partial discharges in equipment with SF6 gas and oil isolation, in order to validate expected signal discharges in the theoretical foundation. These signatures were used in field measurements, which proved the feasibility of the theoretical foundation and signatures obtained in the laboratory. Further factors were raised that may influence the measurements and shown signs that have different characteristics from those of partial discharges in order to differentiate them.
APA, Harvard, Vancouver, ISO, and other styles
2

Castro, Bruno Albuquerque de [UNESP]. "Localização de descargas parciais em transformadores de potência por meio de sensores piezelétricos de baixo custo e sistemas inteligentes." Universidade Estadual Paulista (UNESP), 2016. http://hdl.handle.net/11449/138944.

Full text
Abstract:
Submitted by Bruno Albuquerque de Castro null (bruno.castro@feb.unesp.br) on 2016-06-01T17:52:34Z No. of bitstreams: 1 Bruno_Albuquerque_de_Castro_MestradoEE.pdf: 3788528 bytes, checksum: 28b69717116921fa999eda08254ac160 (MD5)
Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-06-02T19:10:47Z (GMT) No. of bitstreams: 1 castro_ba_me_bauru.pdf: 3788528 bytes, checksum: 28b69717116921fa999eda08254ac160 (MD5)
Made available in DSpace on 2016-06-02T19:10:47Z (GMT). No. of bitstreams: 1 castro_ba_me_bauru.pdf: 3788528 bytes, checksum: 28b69717116921fa999eda08254ac160 (MD5) Previous issue date: 2016-05-25
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
O monitoramento e a localização precoce de descargas parciais em aparelhos de alta tensão, como nos transformadores de potência, são de fundamental importância para a prevenção de problemas funcionais associados à degradação contínua dos materiais que compõe o isolamento elétrico destes tipos de aparelho. Alguns fatores críticos na operação dos transformadores, como o funcionamento em sobrecarga, superaquecimento, transitórios e sinais elétricos de grande conteúdo harmônico vinculados a sistemas chaveados, em longo prazo, fazem com que o sistema de isolação de um transformador apresente degradação de suas propriedades físicas e químicas intrínsecas aos diversos tipos de materiais utilizados para esta finalidade e, deste modo, surjam descargas parciais. Este trabalho teve como objetivo aplicar sensores piezelétricos de baixo custo para a identificação e localização de descargas parciais em transformadores de potência por meio de sistemas inteligentes do tipo Redes Neurais e sistema de inferência neuro fuzzy adaptativos. Ambos os sistemas foram treinados com algumas métricas de processamento de sinais e os resultados de erro médio de localização chegaram na casa dos milímetros. Variou-se o número de sensores acoplados e foi realizado um estudo sobre os resultados de localização obtidos.
Partial discharge damages in power transformers require high cost monitoring procedures based on corrective maintenance or even interruptions of the power system. The development of online non-invasive monitoring systems to detect partial discharges in power transformers has great relevance since it can reduce significant maintenance costs. Some critical factors in the operation of transformers such as overload, nonlinear loads, transient voltage surges by atmospheric origin and switching, can make the insulation system of transformers to lose their physical and chemical properties. Therefore, these operating conditions can cause early deterioration of the insulation, causing internal partial discharges that may develop into major defects and thus shorten the useful life of electrical equipment. This research aimed to apply a low cost piezoelectric sensors for partial discharge identification and location in power transformers through intelligent systems such as neural networks and adaptive fuzzy inference system. Both systems were trained with some signal processing metrics and the results for location error was in the region of millimeters. It was varied the number of coupled sensors and a study was conducted on the obtained location results.
APA, Harvard, Vancouver, ISO, and other styles
3

Palitó, Thamyres Tâmulla Cavalcante. "Detecção acústica de descargas parciais com transdutor piezoelétrico." Universidade de São Paulo, 2015. http://www.teses.usp.br/teses/disponiveis/18/18154/tde-15042015-105937/.

Full text
Abstract:
Os equipamentos elétricos instalados em linhas de transmissão e distribuição de energia são normalmente submetidos a condições anormais e intensos campos elétricos, que, eventualmente, levam, entre outros fenômenos, as descargas parciais (DPs). Estas descargas têm sido apontadas como uma das principais causas de falhas de equipamentos e envelhecimento precoce. Portanto, detectar DPs se tornou uma questão importante na busca de uma energia elétrica eficiente e confiável. No que se refere a detecção de DPs existem vários sensores que podem ser aplicados, a exemplos: óptico, magnético ou acústico, e cada um deles apresentando vantagens particulares e limitações. Uma das desvantagens de tais sensores é o custo elevado, o que restringe o monitoramento de DPs no âmbito da distribuição de energia mais especificamente em transformadores de potência. Embora, se o foco do monitoramento é apenas detectar a ocorrência de DPs, uma nova classe de sensores acústicos implementados com piezoeletretos pode ser uma alternativa econômica viável. Deste modo, nesta dissertação, foi investigado o comportamento acústico de tais transdutores expostos a diferentes condições de DPs, onde o sensor piezoelétrico foi utilizado na detecção de DPs produzidas por uma configuração de eletrodos ponta - ponta separados por diferentes gaps de ar (único ou múltiplo) e excitado por altas tensões alternadas. As amplitudes dos sinais registrados foram correlacionadas com a distância do gap e com a amplitude da tensão aplicada. A partir dos resultados obtidos foi possível observar que a intensidade do som das DPs, capturado com o transdutor piezoelétrico, está relacionada com o tamanho do gap e da amplitude da tensão, como relatado na literatura.
Electrical equipment installed in power transmission and distribution lines are usually subjected to abnormal conditions and intense electric fields, which eventually lead, among others phenomena, to partial discharges (PDs). These discharges have been pointed as one of the main causes of equipment failures and premature aging. Therefore, detect PDs became an important issue in the prospect of efficient and reliable electric energy. Concerning PD detection there are several sensors that can be employed e.g. optical, magnetic or acoustic, and each of them presenting particular advantages and limitations. One of the drawback of such sensors is their elevated cost, which restricts the PD monitoring within the distribution of energy more specifically in power transformers. Although, if the intention of monitoring is only to detect the PD occurrence a new class of acoustic sensors implemented with piezoelectrets may be a feasible economic alternative. Therefore, in this work was investigated the acoustic behavior of such transducers exposed to different PD conditions, for instance, the piezoelectret sensor was employed on the detection of PD produced by a single or multiple point-to-point electrode setup with different air gaps excited by high AC voltages. The recorded signals amplitudes were correlated with the gap distance and voltage amplitude applied. Based on the results obtained it was observed that the intensity of the DPs sound, captured with the piezoelectric transducer, is related to the size of the gap and voltage amplitude, as reported in the literature.
APA, Harvard, Vancouver, ISO, and other styles
4

Gutnik, Yvan. "Estudo dos piezoeletretos na detecção de descargas parciais em transformadores." Universidade de São Paulo, 2014. http://www.teses.usp.br/teses/disponiveis/18/18154/tde-11062014-162615/.

Full text
Abstract:
A detecção de descargas parciais em transformadores consiste em importante metodologia de manutenção preventiva e preditiva. Neste contexto, a proposta desta pesquisa com o uso de sensores acústicos de piezoeletreto apresenta-se como um tema original e altamente relevante no desenvolvimento da tecnologia brasileira. A multidisciplinaridade do tema exigiu a realização de uma extensa pesquisa bibliográfica envolvendo os temas descargas parciais, métodos de detecção das descargas, piezeletricidade, eletretos, piezoeletretos, técnicas de manufatura do piezoeletreto proposto para a detecção de descargas e ferramentas de processamento de sinais, sendo a principal a deconvolução homomórfica. O Trabalho evoluiu para a elaboração de um primeiro protótipo laboratorial, constituído basicamente de um sensor piezoeletreto e um circuito amplificador, ambos abrigados em um invólucro metálico para assegurar uma blindagem eletromagnética. Os primeiros ensaios, em face da característica \"sui generis\" do protótipo, apontaram para a necessidade de novos circuitos e aprimoramento das metodologias desses ensaios laboratoriais, as quais também fazem parte do escopo deste trabalho. O desenvolvimento de um sistema de alta tensão autônomo, eletromagneticamente blindado e gerador de descargas elétricas impulsivas é um exemplo dos circuitos mencionados. A nova metodologia de testes buscou apresentar a evolução do comportamento acústico de uma descarga em diferentes ambientes, isto é, desde sinais sem ecos até sinais carregados com ecos e distorcidos pelo meio. Finalizando o trabalho, outra contribuição importante foi a decisão de analisar os sinais acústicos das descargas parciais pela deconvolução homomórfica, que mostrou ser essencial na remoção de ecos e na reconstrução do sinal acústico original.
Partial discharges acoustic detection is a very important preventive and predictive maintenance tool for transformers. In this research, a new acoustic piezoelectric sensor, based in Brazilian technology, was presented. However, before the construction of the prototype, an extensive literature was analyzed, including partial discharge, methods of discharges detection, piezoelectricity, electrets, piezoelectrets, manufacturing of the piezoelectret proposed to detection of discharges and signal processing tools, in special the homomorphic deconvolution. Basically, the prototype developed consists of a piezoelectret sensor and an amplifier circuit, assembled in a special metallic box, to shield any electromagnetic interference. During the tests, it was detected the need to create new circuits and to improve laboratory methodologies. A new impulse high-voltage generator electromagnetically shielded can be cited as an example of these circuits here developed. The new testing methodology aimed to present the evolution of the acoustic behavior of a discharge in different environments, in other words, from signals without echoes to signals containing echoes and distorted by the environment. In the processing signals context, another important contribution was the decision to analyze the acoustic signals of partial discharges by homomorphic deconvolution, which has allowed the reconstruction of the original acoustic signal without echo.
APA, Harvard, Vancouver, ISO, and other styles
5

Duarte, Rafael Moura. "Localização de fontes de descargas parciais baseada em técnicas radiométricas." Universidade Federal da Paraíba, 2016. http://tede.biblioteca.ufpb.br:8080/handle/tede/8797.

Full text
Abstract:
Submitted by Cristhiane Guerra (cristhiane.guerra@gmail.com) on 2017-01-26T15:29:49Z No. of bitstreams: 1 arquivototal.pdf: 2174658 bytes, checksum: 32615157c634ff96ea0d5edeb9dc6b9b (MD5)
Made available in DSpace on 2017-01-26T15:29:49Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 2174658 bytes, checksum: 32615157c634ff96ea0d5edeb9dc6b9b (MD5) Previous issue date: 2016-07-25
Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq
One way to diagnose the level of electrical insulation degradation is to identify the occurrence of partial discharges (PD). Early detection of defects in insulation enables the programming of electric power equipment maintenance activities. Thus, the electrical system can operate more reliably and with fewer interruptions. In addition to detection, the information provided by pulses of partial discharges allow the location of its source. In this work, the main objective is to develop a hybrid technique of location, based on the time-of-arrival and the energies of PD signals. The performance of the hybrid technique was compared with three other location radiometric techniques. For this purpose, the methods used to estimate time-of-arrival of PD pulses and localization techniques are explained in details. In order to make simulations of this work was to develop a model of ray tracing, which is able to simulate the propagation of the pulse wave environments defined by maps. These results were obtained from four simulation scenarios: free space with noise, room with obstacles and without noise, high-voltage substation without noise and high-voltage substation with noise. The performance of the hybrid technique was inferior to that of the location techniques that depend only on the time-of-arrival, the accuracy is not as affected by multipath. However, the estimate provided by the hybrid technique proves useful as an initial condition for non linear time-of-arrival non linear technique.
Uma forma de diagnosticar o nível de degradação de isolamentos elétricos consiste em identificar a ocorrência de descargas parciais (DP). A detecção precoce de defeitos em isolamentos viabiliza a programação de atividades de manutenção de equipamentos elétricos de potência. Dessa forma, o sistema elétrico pode operar de forma mais confiável e com um número menor de interrupções. Além da detecção, as informações fornecidas pelos pulsos de descargas parciais permitem a localização da sua fonte. Neste trabalho, o principal objetivo é desenvolver uma técnica híbrida de localização, baseada nos instantes de chegada e nas energias dos sinais de DP. O desempenho da técnica híbrida foi comparado com o de outras três técnicas radiométricas de localização. Para este propósito, os métodos usados para estimar os instantes de chegada dos pulsos de DP e as técnicas de localização estão explicados em detalhes. A fim de realizar as simulações deste trabalho, foi desenvolvido um modelo de traçado de raios, que é capaz de simular a propagação dos pulsos de ondas em ambientes definidos por mapas. Os resultados deste trabalho foram obtidos a partir de quatro cenários de simulação: espaço livre com ruído, sala com obstáculos e sem ruído, subestação de alta tensão sem ruído e subestação de alta tensão com ruído. O desempenho da técnica híbrida foi inferior ao desempenho das técnicas de localização que dependem apenas dos instantes de chegada, cuja precisão não é tão afetada pelo multipercurso. No entanto, a estimativa fornecida pela técnica híbrida se mostrou útil como condição inicial para o sistema linear de uma das técnicas e localização pelos instantes de chegada.
APA, Harvard, Vancouver, ISO, and other styles
6

Rodrigo, Mor Armando. "Nueva metodología de la medida de descargas parciales en cables de alta tensión. Desarrollo de un sensor capacitivo de gran ancho de banda." Doctoral thesis, Universitat Politècnica de València, 2012. http://hdl.handle.net/10251/16271.

Full text
Abstract:
En la actualidad la medida de descargas parciales constituye una herramiento eficaz para el diagnóstico de fallos de aislamiento. La presente tesis está centrada en los diferentes métodos de ensayo de descargas parciales en cables de media y alta tensión. Principalmente se ha estudiado la influencia de los diferentes métodos de ensayo en la evaluación de la carga de los pulsos de descargas parciales en ensayos off-line (ensayos en lso que se saca el cable fuera de servicio). La tesis analiza las particularidades de los métodos convencionales, y de los nuevos métodos o métodos no convencionales. Los métodos convencionales, empleados desde los años 60 en laboratorios de alta tensión, emplean filtros paso-banda como herramienta para la evaluación de los pulsos de descargas parciales. Los métodos no convencionales emplean sensores con anchos de banda muy superiores a los métodos convencionales pues esto permite la localización de los pulsos por técnicas de reflectometría y el uso de herramientas matemáticas que ayudan a la identificación de los pulsos de descargas parciales. En esta tesis se proponen y comparan diferentes métodos de evaluación de carga para los métodos no convencionales, y se establecen los límites de la incertidumbre en dichas medidas en función del ancho de banda de los sensores y de la longitud de los pulsos de descargas parciales. La tesis aborda el análisis de los transformadores de corriente de alta frecuencia que comúnmente se emplean como sensores de descargas parciales para medidas acopladas por campo magnético, y el estudio de los sensores acoplados por campo eléctrico. La comparativa de ambos sensores permite extraer conclusiones acerca de los anchos de banda obtenidos, de la incertidumbre alcanzada para diferentes longitudes de pulso y métodos de evaluación de carga, y de la sensibilidad de los sistemas de medida que emplean estos sensores. Las medidas experimentales se han realizado empleando diferentes prototipos de sensores acoplados por
Rodrigo Mor, A. (2012). Nueva metodología de la medida de descargas parciales en cables de alta tensión. Desarrollo de un sensor capacitivo de gran ancho de banda [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/16271
Palancia
APA, Harvard, Vancouver, ISO, and other styles
7

Gomes, Ferraz Adelson. "Modelagem endoscópica virtual do monitoramento de equipamentos elétricos de alta tensão." Universidade Federal de Pernambuco, 2007. https://repositorio.ufpe.br/handle/123456789/2688.

Full text
Abstract:
Made available in DSpace on 2014-06-12T16:00:17Z (GMT). No. of bitstreams: 2 arquivo6352_1.pdf: 3506508 bytes, checksum: d2730a2c9628d30e079fa0dcef4aa7df (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2007
Com o advento da promulgação das Leis 10.847/2004 e 10.848/2004, o Setor Elétrico Brasileiro passou a adotar a competitividade como elemento balizador para obtenção das concessões, seja na transmissão, seja na geração de energia elétrica. Nesse sentido, as empresas do setor terão que intensificar, significativamente, os processos de monitoramento dos equipamentos que constituem o sistema elétrico, de forma a otimizar suas utilizações, repercutindo, em conseqüência, nas decisivas questões de vida útil dos mesmos e, portanto, na confiabilidade, continuidade e qualidade do fornecimento de energia elétrica para a sociedade. O avanço tecnológico ocorrido nas duas últimas décadas, particularmente nos sistemas micro-processados, vem repercutindo em melhorias das ferramentas disponibilizadas para a operação do Sistema Nacional Interligado SIN. Os sistemas de proteção e controle das instalações migraram, nesse período, da tecnologia eletromecânica para a eletrônica analógica e desta para a digital, tornando-se subsistemas bastante eficientes. Com os equipamentos de grande porte, como os geradores, turbinas, transformadores, reatores, dentre outros, não se constatou um avanço de igual intensidade na técnica do monitoramento. Muitas são as situações em que os equipamentos aparentam estar funcionando em condições plenamente satisfatórias quando, na realidade, eles estão submetidos a condições críticas. É como um indivíduo que sofre um ataque cardíaco fulminante, um incremento infinitesimal de estresse no equipamento tornao indisponível e quase sempre o danifica. Dentro deste contexto, essa dissertação de mestrado focaliza as possibilidades de melhor aproveitamento da tecnologia disponível de sensores, particularmente, ópticos, acústicos e micro-processados para otimizar o processo de supervisão e monitoramento de equipamentos, bem como para melhor condicionar a aprendizagem dos fenômenos que, internamente, neles ocorrem. Neste caso o da aprendizagem explorase a técnica de realidade virtual numa visão imediatista para, nos médio e longo prazos, prospectar a possibilidade de investimento em sistemas virtuais on line , aqui entendido como a perspectiva de monitoramento do funcionamento interno do equipamento visualizado em tempo real e em espaço tridimensional. Para atingir os objetivos visualizados, a presente dissertação faz abordagem em três grandes aspectos, adotando uma dinâmica top down , do geral para o particular. O primeiro aspecto aborda o estado atual da arte de monitoramento de equipamentos, de um modo geral, de forma a contextualizar onde estamos . O segundo, apresenta as perspectivas de avanços esperados na aplicação da tecnologia disponível. Neste caso, considerando o grande espectro de equipamentos e possibilidades, bem como para dotar o trabalho de pragmatismo, apresenta-se uma proposta de modelo, cunhado de endoscópico , para um equipamento específico o transformador de potência. Sua escolha deveu-se ao fato de ele se constituir num dos mais caros e importantes equipamentos de um sistema elétrico. Finalmente, o terceiro aspecto enfoca um estudo de caso que permite validar o conceito proposto. Para tanto, foram feitas simulações de descargas parciais no Centro de Pesquisa de Energia Elétrica CEPEL, entidade de renome nacional e que atende, precipuamente, às empresas do Grupo Eletrobrás. Nas simulações, em apreço, enfocando, desta feita, um subconjunto dos problemas de um transformador de potência, foram geradas situações de falhas internas e a partir do uso de fibra óptica e sensores acústicos foi possível mapear a provável localização do defeito, locando-o no espaço tridimensional. Pôde-se concluir, portanto, que pequenas descargas internas que, em números repetidos, resultam na gradativa deteriorização das partes isolantes, podem, a partir do uso adequado de sensores, ser detectadas a tempo hábil, evitando-se uma perda do equipamento, que via de regra repercute em profundo prejuízo para as empresas e para a operação do sistema elétrico. Em síntese, a dissertação apresenta o status atual geral do monitoramento de equipamentos (ou seja, onde estamos), para onde, entendemos que devamos caminhar, inclusive contemplando a técnica de Realidade Virtual e, de forma prática, a partir de um estudo de caso, demonstra não se tratar apenas de uma idéia teórica ou de um desejo sem suporte técnico, mas sim de um objetivo plenamente alcançável
APA, Harvard, Vancouver, ISO, and other styles
8

Costa, Paulo Izidio da. "Sistema inteligente para localização de descargas parciais em transformadores de potência." Universidade de São Paulo, 2015. http://www.teses.usp.br/teses/disponiveis/18/18153/tde-22122015-075739/.

Full text
Abstract:
O crescente aumento na demanda de energia elétrica nacional, associada às alterações regulamentares do setor, em que o tempo que um equipamento permanece indisponível para o sistema, aguardando manutenção significa perda de receita para as companhias de energia, motivou a busca por diagnósticos precisos e utilização de técnicas não invasivas que possam ser aplicadas em transformadores em serviço. Assim, o foco desta pesquisa foi o desenvolvimento de uma arquitetura de sistema inteligente baseado em Redes Neurais Artificiais, que a partir de características extraídas de sinais de emissão acústicas provenientes de sensores distribuídos espacialmente no tanque de transformadores de potência, possa identificar internamente o local de ocorrência das descargas parciais e fornecer as distâncias estimadas entre os sensores e o ponto dessa descarga, e com essas distâncias, utilizando técnicas numéricas de triangulação, o sistema fornece também a coordenada espacial da falha auxiliando no diagnostico de defeito do transformador e no processo de tomada de decisões.
The increasing in the demand for national electrical energy coupled with alterations in the regulation of the sector, where the time which a piece of the electrical system equipment stays out of service means loss of income for the electrical companies, has motivated the search for correct diagnostics and usage of non-invasive technics that can be used in tranformers which are in operation. Therefore, the aim of this research was to develop the design of an intelligent system based on Artificial Neural Nets, which through the characteristics extracted from the acoustic emission signals coming from the sensors spatially distributed in the power transformer tank can identify internally the place of the occourrence of the partial discharges and provide the estimate distances between the sensors and the discharges point, so with these distances using triangle technical analysis the system will also provide the spatial coordinate of the flaw for diagnosing the problem with the transformer and help the process of decision making.
APA, Harvard, Vancouver, ISO, and other styles
9

VILHENA, Paulo Roberto Moutinho de. "Sistema para detecção, localização e monitoramento de descargas parciais em estatores de hidrogeradores." Universidade Federal do Pará, 2015. http://repositorio.ufpa.br/jspui/handle/2011/7745.

Full text
Abstract:
Submitted by camilla martins (camillasmmartins@gmail.com) on 2017-02-21T16:55:41Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_SistemaDeteccaoLocalizacao.pdf: 3882901 bytes, checksum: 704c5396d2a1a1048e29301da59eb483 (MD5)
Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-02-22T15:53:25Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_SistemaDeteccaoLocalizacao.pdf: 3882901 bytes, checksum: 704c5396d2a1a1048e29301da59eb483 (MD5)
Made available in DSpace on 2017-02-22T15:53:25Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_SistemaDeteccaoLocalizacao.pdf: 3882901 bytes, checksum: 704c5396d2a1a1048e29301da59eb483 (MD5) Previous issue date: 2015-11-30
Paradas de máquinas não planejadas causadas por falhas na isolação elétrica de equipamentos do sistema elétrico de potência são um grande problema, pois contabilizam elevadas perdas para planta e comprometem os indicadores de desempenho devido extenso período de parada da unidade geradora necessário para restauração da função geração. A fim de solucionar esse problema, vários pesquisadores e estudiosos da área de grandes máquinas rotativas descobriram que estas falhas estavam frequentemente relacionadas com o aumento do nível de descargas parciais da isolação elétrica da máquina. As ocorrências das DP nos sistemas isolantes dos equipamentos de alta tensão são sintomas de fragilidade na sua suportabilidade dielétrica, cuja evolução pode ocasionar graves consequências para o equipamento. Em virtude dessas consequências, a avaliação do estado operativo do enrolamento estatórico, por meio do sistema de medição de DP on line proposto nesta tese apresenta estratégias para aumentar a confiabilidade das medições. Como sensor de DP, foi sugerido usar acoplador direcional eletromagnético de microfita capaz de detectar o sinal com maior largura de banda na faixa UHF, comparado com os sensores tradicionais existentes. O desenvolvimento e a implementação do simulador virtual de DP decorreu da necessidade de se ter exemplos de sinais que permitissem testar algumas técnicas de processamento de sinais DP. O principal resultado da tese é o sistema de medição de DP (denominado SIM_DP) que inclui sensor, sistema de aquisição de dados, software de processamento de sinais de DP e de análise dos resultados. Ao estudar a propagação do sinal em uma barra estatórica foi possível desenvolver uma nova metodologia baseada em análise espectral para localização de DP. Por meio da estrutura montada em laboratório, foi possível validar o sistema SIM_DP o que favoreceu a análise crítica do fenômeno DP. Por fim foram analisados dados reais de medições de DP em campo e correlação das DP com vibrações mecânicas. Os resultados do trabalho contribuíram para um diagnóstico mais preciso do fenômeno. Os resultados da tese têm sido aprimorados em laboratório e em campo produzindo novos: implementação de novos ensaios em laboratório como envelhecimento acelerado de barras, novos sensores não invasivos como antenas capazes de medir descargas parciais e novas técnicas empregadas na análise e diagnóstico dos fenômenos relacionados com DP que serão apresentadas em trabalhos futuros.
Stops machines unplanned caused by faults in the electrical insulation of the power electric system equipment is a big problem, because account for high losses to plan and undertake performance indicators due long stop period generating unit necessary for the generation function restoration. In order to solve this problem, many researchers and scholars in the field of large rotating machines found that these failures were often related to the increased level of partial discharges (PDs) of electrical insulation of the machine. Occurrences of PDs in insulating systems of high voltage equipment are symptoms of weakness in their dielectric withstand, whose evolution can cause serious consequences for the equipment. Because of these consequences, the evaluation of the operating status of the stator winding through the on line PDs measurement system proposed in this thesis presents strategies to increase the reliability of the measurements. As PDs sensor, it has been suggested to use electromagnetic microstrip directional coupler can detect the signal with the highest bandwidth in the UHF band, compared to existing traditional sensors. The development and implementation of virtual simulator PDs caused by the need of having Examples of signals that allow testing some PDs signal processing techniques. The main result of this thesis is the DP measurement system (called SIM_DP) including sensor, data acquisition system, PDs signal processing software and analysis of results. By studying the propagation of the signal in a stator bar was possible to develop a new methodology based on spectral analysis for PDs location. Through the structure created in the laboratory, it was possible to validate the SIM_DP system which favored the review of the PDs phenomenon. Finally actual data were analyzed for DP measurements in the field and correlation of PDs with mechanical vibration. The results of the work contributed to a more accurate diagnosis of the phenomenon. The results of the thesis have been improved in laboratory and field producing new: implementation of new laboratory tests as Voltage Endurance Test (VET), new non-invasive sensors such as antennas capable of measuring partial discharges and new techniques used in the analysis and diagnosis of related DP phenomena which will be presented in future work.
APA, Harvard, Vancouver, ISO, and other styles
10

Américo, Jônatas Policarpo 1987, Sérgio Henrique Lopes 1965 Cabral, and Universidade Regional de Blumenau Programa de Pós-Graduação em Engenharia Elétrica. "Estudo de técnicas de medição de descargas parciais em transformadores de potência." reponame:Biblioteca Digital de Teses e Dissertações FURB, 2013. http://www.bc.furb.br/docs/DS/2013/359271_1_1.pdf.

Full text
Abstract:
Orientador: Sérgio Henrique Lopes Cabral.
Dissertação (Mestrado em Engenharia Elétrica) - Programa de Pós-Graduação em Engenharia Elétrica, Centro de Ciências Tecnológicas, Universidade Regional de Blumenau, Blumenau.
APA, Harvard, Vancouver, ISO, and other styles
More sources

Book chapters on the topic "Descarga parcial"

1

Barbosa, Brendo Silva, Pyramo Pires da Costa Júnior, Rose Mary de Souza Batalha, and Daniel Furtado Leite. "Sensores virtuais para detecção de descargas parciais em transformadores de potência." In Engenharia no Século XXI – Volume 22. Editora Poisson, 2021. http://dx.doi.org/10.36229/978-65-5866-112-2.cap.11.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Batista, Paulo Vitor do Carmo, and Hilton de Oliveira Mota. "REPRESENTAÇÃO ESPARSA UTILIZANDO WAVELETS E VARIAÇÃO TOTAL APLICADOS AO PROCESSAMENTO DE SINAIS DE DESCARGAS PARCIAIS." In Técnicas de Processamento de Sinais e Telecomunicações, 135–51. Atena Editora, 2019. http://dx.doi.org/10.22533/at.ed.49819080713.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Narimatsu, Renata Tiemi, and Patricia Almeida Sacramento. "DIAGNÓSTICO DOS RESÍDUOS SÓLIDOS GERADOS EM RESTAURANTES NO MUNICÍPIO DE UMUARAMA – PARANÁ." In AVALIAÇÃO PRELIMINAR DA QUALIDADE DA ÁGUA SUBTERRÂNEA DA REGIÃO DE FEIRA DE SANTANA E MUNICÍPIOS LIMÍTROFES, 120–34. Bookerfield Editora, 2021. http://dx.doi.org/10.53268/bkf21060709.

Full text
Abstract:
O Plano de Gerenciamento de Resíduos Sólidos (PGRS) inserido na Política Nacional de Resíduos Sólidos tem como intuito manejar os resíduos de forma correta e destiná-los a um ambiente adequado. Dada à importância de gerenciar os resíduos sólidos, este trabalho objetivou realizar um diagnóstico dos resíduos sólidos para quatro restaurantes com intuito de auxiliar na redução destes resíduos e dessa forma destiná-los corretamente. A metodologia utilizada neste estudo consiste em duas etapas, sendo a primeira a definição da área de estudo e segunda a amostragem, que consistiu na segregação dos resíduos, pesagem dos resíduos, e o panorama geral, com propostas de melhorias. Percebeu-se que todos os restaurantes destinam parte dos resíduos orgânicos para propriedades rurais, a fim de reaproveitá-los, utilizando-os para a alimentação de animais. No entanto, constatou-se que ainda existe uma parcela de alimento sendo desperdiçada devido à falta de segregação dos resíduos logo no início do descarte. O diagnóstico elaborado prevê a adição de mais coletores para segregação adequada dos resíduos orgânicos e recicláveis desperdiçados, para que estes possam ser destinados a compostagem e a cooperativa de reciclagem do município. O estudo prevê ainda a substituição de utensílios utilizados em três restaurantes para que possam, a longo prazo, diminuir o consumo de recicláveis e como consequência reduzir os custos financeiros dos estabelecimentos.
APA, Harvard, Vancouver, ISO, and other styles

Conference papers on the topic "Descarga parcial"

1

Maurício R. de Souza Neto, José, and Helon David de Macêdo Braz. "Otimização Matemática para o Método Radiométrico de Estimação da Localização de Descargas Parciais Baseado em Razão das Potências." In Simpósio Brasileiro de Sistemas Elétricos - SBSE2020. sbabra, 2020. http://dx.doi.org/10.48011/sbse.v1i1.2396.

Full text
Abstract:
O processo de medição de descargas parciais tem uma longa história como ferramenta de avaliação de envelhecimento de equipamentos de alta tensão. A localização, porém, ainda é um problema a ser superado. Identificar um equipamento com falhas de isolamento dentro de uma subestação é realizado por meio de campanhas de medição através de toda a subestação, ou no caso de um equipamento cujo nível de descarga parcial já esteja alto o suficiente para despertar desconfiança dos operadores. Desse modo, ter uma ferramenta de localização de descargas parciais é uma necessidade para o processo de gestão de equipamentos e recursos. No presente trabalho é descrito o processo de otimização matemática aplicado na solução de algoritmos de localização para métodos radiométricos de detecção de descargas parciais. São considerados modelos de propagação do sinal, bem como estratégias de minimização de erro para otimização da solução.
APA, Harvard, Vancouver, ISO, and other styles
2

Cuenca, Walter M. H., Alain F. S. Levy, Sandoval C. Junior, and José M. Seixas. "REMOÇÃO DO RUÍDO GAUSSIANO E OUTLIERS PARA MEDIÇÃO DE DESCARGA PARCIAL EM EQUIPAMENTOS DE ALTA TENSÃO UTILIZANDO A ANÁLISE DE COMPONENTES INDEPENDENTES." In 9. Congresso Brasileiro de Redes Neurais. SBRN, 2016. http://dx.doi.org/10.21528/cbrn2009-169.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Fernandes Ribeiro, Guilherme, and Hélder De Paula. "Diagnóstico e Monitoramento de Cabos Isolados através da Análise de Descargas Parciais: O Estado da Arte." In Congresso Brasileiro de Automática - 2020. sbabra, 2020. http://dx.doi.org/10.48011/asba.v2i1.1534.

Full text
Abstract:
Este trabalho apresenta uma ampla e minuciosa revisão bibliográfica sobre a avaliação de descargas parciais para o diagnóstico e monitoramento do estado da isolação de cabos de média e alta tensão. Todos os possíveis métodos de detecção da atividade de descargas parciais, com os respectivos sensores adequados para cada situação, são discutidos de forma a explicitar suas vantagens, limitações e aplicações. É apresentada também uma avaliação dos métodos e parâmetros utilizados no tratamento dos dados de medição e discutido como os mesmos influenciam na distinção entre os sinais associados a descargas parciais e ruídos externos do sistema. Por fim, de forma ilustrar a aplicação das técnicas discutidas, são apresentados relatos de casos encontrados na literatura nos quais foram empregadas metodologias de monitoramento baseadas no controle dos níveis de descargas parciais em cabos isolados e adotadas estratégias de manutenção baseadas nesse princípio.
APA, Harvard, Vancouver, ISO, and other styles
4

De S. M. Torres, Igor, Fernando A. Moreira, and Edson G. Costa. "Avaliação de diagnósticos por descargas parciais para máquinas elétricas." In Simpósio Brasileiro de Sistemas Elétricos - SBSE2020. sbabra, 2020. http://dx.doi.org/10.48011/sbse.v1i1.2493.

Full text
Abstract:
O diagnóstico do isolamento de máquinas elétricas de grande porte por meio de sua atividade de descargas parciais vem se provando como uma importante ferramenta de manutenção preditiva, garantindo maior previsibilidade operacional dos ativos das empresas. Para conseguir extrair todo o potencial da ferramenta, o processo de aquisição e filtragem dos sinais de descargas parciais é uma etapa fundamental. O objetivo desse artigo é apresentar três modalidades de tratamento desses dados e comparando com um diagnóstico real de um turbogerador em uma usina termelétrica.
APA, Harvard, Vancouver, ISO, and other styles
5

Morais Gon¸calves J´unior, Arismar, Rog´erio Andrade Flauzino, H´elder De Paula, and Sofia Moreira de Andrade Lopes. "Eliminação Recursiva de Características (SVM-RFE) para a Localização de Descargas Parciais em Transformadores." In Congresso Brasileiro de Automática - 2020. sbabra, 2020. http://dx.doi.org/10.48011/asba.v2i1.1438.

Full text
Abstract:
A investigação de descargas parciais (PDs) em transformadores possibilita a identificação antecipada e localização de falhas incipientes nestes equipamentos, o que pode evitar consideráveis perdas financeiras. Para o desenvolvimento de tais técnicas de localização, no entanto, uma etapa fundamental se refere à extração e seleção de atributos dos sinais das PDs, parâmetros que podem influenciar diretamente no desempenho do método utilizado. Visando a determinação de um melhor conjunto de características para a localização das descargas parciais, o método de seleção SVM-RFE é investigado neste trabalho, com base em parâmetros extraídos de sinais de emissão acústica das PDs. Os resultados mostram que o método SVM-RFE é capaz de selecionar as características mais adequadas para a localização das PDs, reduzindo o espaço de características inicial, além de indicar que um menor número de sensores pode ser empregado nas medições das descargas.
APA, Harvard, Vancouver, ISO, and other styles
6

Gonçalves Júnior, Arismar Morais, Hélder de Paula, and Wallace do Couto Boaventura. "Extração de Características na Localização de Descargas Parciais em Transformadores." In ANAIS DO 14º SIMPóSIO BRASILEIRO DE AUTOMAçãO INTELIGENTE. Galoa, 2019. http://dx.doi.org/10.17648/sbai-2019-111269.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Lucena, Oeslle, Euler Macêdo, Waslon Lopes, and Edson Costa. "Transformada Wavelet Aplicada ao Tratamento de Sinais de Descargas Parciais." In XXX Simpósio Brasileiro de Telecomunicações. Sociedade Brasileira de Telecomunicações, 2012. http://dx.doi.org/10.14209/sbrt.2012.95.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Silva Barbosa, Brendo, Daniel Leite, Pyramo Pires da Costa Jr., and Rose Mary de Souza Batalha. "Sensores Virtuais para Detecção de Descargas Parciais em Transformadores de Potência." In ANAIS DO 14º SIMPóSIO BRASILEIRO DE AUTOMAçãO INTELIGENTE. Galoa, 2019. http://dx.doi.org/10.17648/sbai-2019-111186.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Neto, J., and Fabricio Carvalho. "Simulação de Pulsos de Descargas Parciais para Sistemas de Detecção Radiométricos." In XXXVI Simpósio Brasileiro de Telecomunicações e Processamento de Sinais. Sociedade Brasileira de Telecomunicações, 2018. http://dx.doi.org/10.14209/sbrt.2018.17.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Batista, Paulo, Hilton Mota, and Flávio Vasconcelos. "Processamento de Sinais de Descargas Parciais utilizando Wavelets e Variação Total." In XXXVI Simpósio Brasileiro de Telecomunicações e Processamento de Sinais. Sociedade Brasileira de Telecomunicações, 2018. http://dx.doi.org/10.14209/sbrt.2018.272.

Full text
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!

To the bibliography