Dissertations / Theses on the topic 'Diagnostic parameters'
Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles
Consult the top 50 dissertations / theses for your research on the topic 'Diagnostic parameters.'
Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.
You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.
Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.
Konala, Bhaskar Chandra. "Effect of Arterial Wall-Stenosis Compliance on Coronary Diagnostic Parameters." University of Cincinnati / OhioLINK, 2010. http://rave.ohiolink.edu/etdc/view?acc_num=ucin1291146768.
Full textBencalík, Karol. "Diagnostika hydraulických soustav letadel." Doctoral thesis, Vysoké učení technické v Brně. Fakulta strojního inženýrství, 2014. http://www.nusl.cz/ntk/nusl-234202.
Full textLu, Ying 1968. "Bayesian estimation of diagnostic test parameters in the presence of verification bias." Thesis, McGill University, 2006. http://digitool.Library.McGill.CA:80/R/?func=dbin-jump-full&object_id=98755.
Full textPeelukhana, Srikara Vishwanath. "Effect of coronary collateral flow on diagnostic parameters: An In vitro study." University of Cincinnati / OhioLINK, 2009. http://rave.ohiolink.edu/etdc/view?acc_num=ucin1258473630.
Full textGoswami, Ishan. "Influence of geometric and flow variations on coronary diagnostic parameters: An in-vitro study." University of Cincinnati / OhioLINK, 2013. http://rave.ohiolink.edu/etdc/view?acc_num=ucin1367937429.
Full textNedanovska, E. N. "Thomson scattering from technological plasmas." Thesis, Queen's University Belfast, 2013. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.580125.
Full textZanten, Anton Pieter van. "Central nervous system metastases from extracranial malignancies diagnostic value of clinical chemical parameters /." Amsterdam : Maastricht : Rodopi ; University Library, Maastricht University [Host], 1986. http://arno.unimaas.nl/show.cgi?fid=5309.
Full textSubramony, Anantha Krishna. "Efficacy of New Diagnostic Parameters for Determining Arteriovenous Fistula Functionality: A Numerical Study." University of Cincinnati / OhioLINK, 2016. http://rave.ohiolink.edu/etdc/view?acc_num=ucin1470753788.
Full textGomez, Carrillo Andrea. "Low Frequency Oscillations of Hemodynamic Parameters as a Novel Diagnostic Measure for Traumatic Brain Injury." Wright State University / OhioLINK, 2021. http://rave.ohiolink.edu/etdc/view?acc_num=wright1627226821857103.
Full textLienhardt, Stephanie Barbara. "Diagnostic criteria and follow-up parameters in Complex Regional Pain Syndrome type I : a Delphi survey /." [S.l.] : [s.n.], 2009. http://opac.nebis.ch/cgi-bin/showAbstract.pl?sys=000281140.
Full textLança, Luís Jorge Oliveira Carrasco. "Radiological imaging in digital systems: the effect of exposure parameters in diagnostic quality and patient dose." Doctoral thesis, Universidade de Aveiro, 2011. http://hdl.handle.net/10773/3950.
Full textEsta tese pretende contribuir para o estudo e análise dos factores relacionados com as técnicas de aquisição de imagens radiológicas digitais, a qualidade diagnóstica e a gestão da dose de radiação em sistema de radiologia digital. A metodologia encontra-se organizada em duas componentes. A componente observacional, baseada num desenho do estudo de natureza retrospectiva e transversal. Os dados recolhidos a partir de sistemas CR e DR permitiram a avaliação dos parâmetros técnicos de exposição utilizados em radiologia digital, a avaliação da dose absorvida e o índice de exposição no detector. No contexto desta classificação metodológica (retrospectiva e transversal), também foi possível desenvolver estudos da qualidade diagnóstica em sistemas digitais: estudos de observadores a partir de imagens arquivadas no sistema PACS. A componente experimental da tese baseou-se na realização de experiências em fantomas para avaliar a relação entre dose e qualidade de imagem. As experiências efectuadas permitiram caracterizar as propriedades físicas dos sistemas de radiologia digital, através da manipulação das variáveis relacionadas com os parâmetros de exposição e a avaliação da influência destas na dose e na qualidade da imagem. Utilizando um fantoma contrastedetalhe, fantomas antropomórficos e um fantoma de osso animal, foi possível objectivar medidas de quantificação da qualidade diagnóstica e medidas de detectabilidade de objectos. Da investigação efectuada, foi possível salientar algumas conclusões. As medidas quantitativas referentes à performance dos detectores são a base do processo de optimização, permitindo a medição e a determinação dos parâmetros físicos dos sistemas de radiologia digital. Os parâmetros de exposição utilizados na prática clínica mostram que a prática não está em conformidade com o referencial Europeu. Verifica-se a necessidade de avaliar, melhorar e implementar um padrão de referência para o processo de optimização, através de novos referenciais de boa prática ajustados aos sistemas digitais. Os parâmetros de exposição influenciam a dose no paciente, mas a percepção da qualidade de imagem digital não parece afectada com a variação da exposição. Os estudos que se realizaram envolvendo tanto imagens de fantomas como imagens de pacientes mostram que a sobreexposição é um risco potencial em radiologia digital. A avaliação da qualidade diagnóstica das imagens mostrou que com a variação da exposição não se observou degradação substancial da qualidade das imagens quando a redução de dose é efectuada. Propõe-se o estudo e a implementação de novos níveis de referência de diagnóstico ajustados aos sistemas de radiologia digital. Como contributo da tese, é proposto um modelo (STDI) para a optimização de sistemas de radiologia digital.
In the present study an attempt has been made to contribute for the analysis of the factors related with the technical acquisition, the quality of the diagnostic image and dose management in digital detector systems for projection radiography. The thesis methodology is organized in two components. The observational component is based on a retrospective and transversal design. The data collected from CR and DR systems allowed the evaluation of exposure parameters from digital images, absorbed dose and exposure index to the detector. Under this classification (retrospective and transversal design) it was also possible to develop diagnostic quality evaluations from digital radiographic images: observer performance studies from digital images stored in the PACS. Under the experimental component of this thesis several experiments using phantoms were performed in order to evaluate the relation between dose and image quality. The experiments allowed the characterization of physical properties of digital image systems and manipulation of variables such as those related to exposure parameters and evaluation of its influence in dose and image quality. Using a contrast-detail phantom, anthropomorphic phantoms and an animal bone phantom it was possible to provide objective measures concerning the quantification of diagnostic quality and measures of object detectability. According to the research undertaken several conclusions could be highlighted. Quantitative measures of DR and CR detectors performance provide a basis for optimization, allowing to measure and determinate the physical properties of digital radiology image systems. Exposure parameters being used in digital radiography shows that current routine radiographic practice does not comply with European guidelines concerning exposure techniques. There is a need to evaluate, improve and establish a baseline reference aiming exposure optimization and provide new guidelines for current digital systems. Exposure parameters influence patient dose in digital radiology but image quality perception seems not to be affected with exposure variation. Studies performed both with phantoms and patients showed that overexposure is a potential risk when working with digital systems. Evaluation of diagnostic quality of digital images when a variation of exposure parameters is provided showed no substantial decrease in image quality when dose reduction is achieved. New dose reference levels should be studied and implemented according to the digital system characteristics and performance. A conceptual framework (STDI) is proposed as an attempt to provide a practical method to optimize digital radiology systems.
FCT/PROTEC
Rajabi, Jaghargh Ehsan. "Effects of hemodynamic stresses on the remodeling parameters in arteriovenous fistula." University of Cincinnati / OhioLINK, 2015. http://rave.ohiolink.edu/etdc/view?acc_num=ucin1427962400.
Full textDyachuk, Eduard. "Load diagnostic of power lines to control and optimize the utilization of wind energy." Thesis, Mälardalens högskola, Akademin för hållbar samhälls- och teknikutveckling, 2010. http://urn.kb.se/resolve?urn=urn:nbn:se:mdh:diva-10090.
Full textBai, Xueshi. "Laser-induced plasma as a function of the laser parameters and the ambient gas." Thesis, Lyon 1, 2014. http://www.theses.fr/2014LYO10333/document.
Full textLaser-induced breakdown spectroscopy (LIBS) has been invented for more than 50 years, which analyzes the spectrum of the laser-induced plasma to determine the elemental composition of the ablated sample. Recently, LIBS technique has been well developed and applied in different domains, for example oceanic exploration, pollution monitoring in the environment. LIBS uses the ablation plasma as a light source that contains the elemental composition information of the sample. However, the laser-induced plasma exhibits a transient behavior. Although time-resolved and gated detection can greatly improve the performance of the LIBS technique especially that of calibration-free LIBS (CF-LIBS) with a better determination of plasma temperature, the temporal evolution of the plasma is correlated to its morphology and its spatial inhomogeneity. The determination of the morphology as well as the internal structure of the plasma together with their evolution during plasma expansion into the ambient gas is therefore crucial for the optimization of the use of ablation plasma as a spectroscopic emission source. Evolutions of the morphology and the internal structure of the ablation plasma are considered as the consequence of its hydrodynamic expansion into the ambient gas. Following the thesis of Qianli Ma which has studied the effect of laser wavelength on the behavior of the plasma induced in an ambient gas of argon, the present thesis has used the same diagnostic techniques (time- and space-resolved emission spectroscopy and fast spectroscopic images) together with 1064 nm ns laser pulse ablation of a target of aluminum to investigate the effects of other parameters, such as the fluence and the duration of laser pulse, the effect of different ambient gases (argon and air), on the morphology and internal structure of the plasma. Furthermore, in order to understand the effects of these parameters on the properties of the plasma, the microscopic mechanisms during post ablation and the propagation of the plasma are also studied. While the plasma cools down in air, molecules are formed, AlO for instance. So the thesis also studied the condition for the formation of the molecules in the plasma. Beyond the practical interest of this study for LIBS, it provides also insights to the kinetics of the AlO molecule formation in laserinduced plasma
D, Souza Gavin A. "Influence of Serial Coronary Stenoses on Diagnostic Parameters: An In-vitro Study with Numerical Validation." University of Cincinnati / OhioLINK, 2014. http://rave.ohiolink.edu/etdc/view?acc_num=ucin1397234083.
Full textKumar, Hemant. "Software analytical tool for assessing cardiac blood flow parameters /." View thesis, 2001. http://library.uws.edu.au/adt-NUWS/public/adt-NUWS20030724.122149/index.html.
Full text胡夕春 and Xichun Hu. "Study on the use of potential prognostic parameters in breast cancer patients." Thesis, The University of Hong Kong (Pokfulam, Hong Kong), 2001. http://hub.hku.hk/bib/B30158138.
Full textD, Souza Gavin A. "Evaluation of Pulmonary Artery Dysfunction in Congenital Heart Disease Patients using Functional-Anatomical Diagnostic Parameters and 4D MRI." University of Cincinnati / OhioLINK, 2018. http://rave.ohiolink.edu/etdc/view?acc_num=ucin1544692345671142.
Full textPham, Dinh Anh Khoi [Verfasser]. "A new method in determination of electrical parameters for failure diagnostic applicable to power transformers / Dinh Anh Khoi Pham." Hannover : Technische Informationsbibliothek und Universitätsbibliothek Hannover (TIB), 2013. http://d-nb.info/1047413752/34.
Full textOumri, Mohamed. "Diagnostic des défauts de réseaux électriques filaires par la réflectométrie." Thesis, Paris 11, 2014. http://www.theses.fr/2014PA112090/document.
Full textThis thesis focuses on fault diagnosis of wired electric networks using reflectometry. To develop diagnostic algorithms, we studied the direct problem (numerical simulations of electrical networks) and the inverse problem (determination of certain properties of a network from reflectometry measurements). For the direct problem, we developed a method for the computation of reflection coefficients. This method is based on the successive solving for a Riccati differential equation. We also generalized the BLT equation for the nonuniform electric networks and automated the resolution of this method. The thesis has made two new results concerning the inverse problem. The first result concerns the estimation of lengths and loss coefficients of the branches of a star network via an iterative method. The second focuses on the identification, at least partially, of the branches admittance matrices of a electric network modeled by the equation of BLT. The methodologies and formalisms proposed in this thesis are validated either by numerical simulations or by real measurements
KrishnankuttyRema, Resmi. "Quantification and Analysis of the Geometric Parameters of the Total Cavo Pulmonary Connection Using a Skeletonization Approach." Thesis, Georgia Institute of Technology, 2007. http://hdl.handle.net/1853/19742.
Full textHarasim, Tomáš. "Návrh diagnostické soustavy pro malý dopravní letoun." Master's thesis, Vysoké učení technické v Brně. Fakulta strojního inženýrství, 2015. http://www.nusl.cz/ntk/nusl-231664.
Full textPedrosa, Ana Rita Ponce Álvares de Águeda. "Cólicas em equinos: tratamento médico vs cirúrgico - critérios de decisão." Bachelor's thesis, Universidade Técnica de Lisboa. Faculdade de Medicina Veterinária, 2008. http://hdl.handle.net/10400.5/939.
Full textA cólica, ou dor abdominal aguda, é um sinal inespecífico que pode ter origem em disfunções do tracto gastrointestinal ou outras que não envolvam o mesmo, sendo neste caso denominada “falsa cólica”. A cólica é responsável pelo maior número de mortes em equinos, à excepção de morte por idade avançada. A etiologia das doenças do tracto gastrointestinal dos equinos que levam à cólica é complexa e diversa. Ainda por explicar permanecem alguns deslocamentos intestinais ou torções e impactações. Na prática clínica diária a maioria dos casos de cólica tem causa desconhecida, mas em geral, resultam da distensão do intestino por ingesta, gás, fluidos ou devido a uma interrupção da motilidade normal do intestino (Íleo). Os casos mais severos podem também resultar de danos da parede intestinal por processos de isquémia, inflamação, edema ou enfarte. No diagnóstico desta afecção existem vários parâmetros que devem ser avaliados, tais como: grau de dor; distensão abdominal; frequência cardíaca, respiratória e características do pulso; coloração das membranas mucosas; tempo de repleção capilar; temperatura rectal; motilidade gastrointestinal; refluxo gástrico; achados à palpação rectal; hematócrito; concentração plasmática de proteínas totais; concentração plasmática de fibrinogénio; contagem de leucócitos; quantificação electrolítica; análise de gases sanguíneos; quantificação das enzimas séricas; concentração de lactato plasmático; características do fluido peritoneal recolhido por abdominocentése; achados ecográficos; achados radiográficos; achados à endoscopia; achados à laparoscopia; e análise fecal. O objectivo deste trabalho consistiu no estabelecimento de pontos orientadores na difícil decisão da terapêutica a adoptar na cólica equina, analisando os vários parâmetros de diagnóstico que, conjuntamente, permitem alcançar um diagnóstico mais preciso da afecção em causa e como tal, poder tomar-se uma decisão mais acertada quanto ao tratamento a seguir, seja ele médico ou cirúrgico. No estudo efectuado sobre 13 casos de cólica abdominal, verificou-se que os casos cirúrgicos foram acompanhados de uma dor mais violenta, e apresentaram frequências cardíacas e tempos de repleção capilar superiores aos dos pacientes que necessitaram apenas de tratamento médico, enquanto que a concentração plasmática de proteínas totais foi superior nos casos médicos. Dos resultados do estudo efectuado e de outros estudos já previamente existentes concluiu-se que quando existe um grau de dor severa, achados anormais à palpação rectal e ausência de resposta à terapêutica analgésica, deve-se referenciar o paciente para cirurgia, mesmo que a frequência cardíaca, coloração das membranas mucosas, tempo de repleção capilar, e análise do fluido peritoneal estejam dentro dos valores normais.
ABSTRACT The colic, or acute abdominal pain, is a non specific sign which can be originated by several disorders of the gastrointestinal tract or others that do not regard this last one, in which case the colic is named “false colic”. The true colic is responsible for the majority of deaths in horses, except those cases in which horses die due to advanced aging. The aetiology of the disorders of the gastrointestinal tract that lead to equine colic is complex and diverse. Still, with no explanation remain some gut displacements or twists and impactions. In the practical daily clinic the majority of colic cases have an unknown cause, but in general, they are a result of gut distention by ingesta, gas, fluids or due to an interruption of the normal motility (Íleus). The most severe cases can also result from damages of the intestinal wall by processes of isquemia, inflammation, edema or infarction. In the diagnosis of this pathology there are several parameters that must be evaluated, such as: pain degree; abdominal distention; the respiratory, heart and pulse rate; mucous membranes; membrane refill time; rectal temperature; gastrointestinal motility; gastric reflux; findings in rectal examination; packed cell volume; total plasma protein value; plasma fibrinogen value; white blood cell count; electrolytic quantification; analysis of blood gases; quantification of serum enzymes; plasma lactate value; characteristics of the peritoneal fluid collected by abdominal paracentesis; ultrasonographic findings; radiographic findings; endoscopic findings; laparoscopic findings; and fecal analysis. The goal of this work consisted on the establishment of guiding points in the difficult decision of the appropriate treatment, analyzing some parameters of diagnosis that, jointly, supply tracks to reach a more specific diagnosis of the disorder which is causing the abdominal pain, and as such to be able to make the right decision regarding the necessary treatment, being either surgical or medical. The study, which was carried on 13 cases of abdominal colic, has shown that surgical cases had a more violent pain, and had presented a higher heart rate and membrane refill time than the patients who only needed medical treatment, whereas the total plasma protein value was higher in medical cases. From these results and other previously existing studies, one can conclude that when exists a severe degree of pain, abnormal findings in the rectal examination and absence of response to the analgesic therapy, the colic case must be referred for surgery, even thought there are no significant changes in the heart rate, mucous membrane, membrane refill time and in the analysis of the peritoneal fluid.
Alexander, George W. A. "Determination of parameters related to the output of diagnostic X-ray sets by calculations based on the results of direct measurement of the spectral output." Thesis, University of Ulster, 1993. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.357790.
Full textPinto, Ferreira Philippe Daniel [Verfasser], and Andrés [Akademischer Betreuer] Kecskeméthy. "Development of Functional Numerical Scores for Improving the Diagnostic of Motion Impairment of Stroke Patients using Non-Traditional Gait Parameters / Philippe Daniel Pinto Ferreira ; Betreuer: Andrés Kecskeméthy." Duisburg, 2017. http://d-nb.info/1132510627/34.
Full textHolušová, Kateřina. "Standardizace a harmonizace znalecké metodiky pro potřeby Forenzní ekotechniky: les a dřeviny." Doctoral thesis, Vysoké učení technické v Brně. Ústav soudního inženýrství, 2012. http://www.nusl.cz/ntk/nusl-234301.
Full textŠpatenka, Jan. "Palubní počítač s testovací jednotkou pro osobní automobily." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2012. http://www.nusl.cz/ntk/nusl-219838.
Full textЦыплакова, Е. С., and E. S. Tsyplakova. "Исследование профессионального мышления студентов-психологов : магистерская диссертация." Master's thesis, б. и, 2021. http://hdl.handle.net/10995/100001.
Full textThe object of the study is the professional thinking of psychology students. The subject of the study was predictors of the development of diagnostic thinking. The master's thesis consists of an introduction, three chapters, a conclusion, a list of references (61 sources) and an appendix that includes the results of the methods (in points) and the content of the test. The volume of the master's thesis is 94 pages, which contain 1 figure and 5 tables. The introduction reveals the relevance of the research problem, the development of the problem, sets the goal and objectives of the research, defines the object and subject of the research, formulates hypotheses, specifies methods and empirical base, as well as the stages of the research, the theoretical and practical significance of the work. The first chapter includes a review of foreign and domestic literature on the topic of research of professional thinking of psychologists and psychology students. The sections that reveal the structure of the phenomenon, its parameters and mechanisms are presented. The conclusions of the first chapter are the results of the study of the theoretical material. The second chapter is devoted to the practical work of a psychologist. It highlights psychodiagnostics as the main practical activity of a psychologist. The structure, mechanisms and features of writing a diagnostic conclusion by a psychologist are considered. Psycholinguistic parameters are determined for evaluating the final conclusions of students. To reveal the features of the intellectual and personal characteristics of the written speech of the psychologist. The conclusions of chapter 2 include the main results. The third chapter is devoted to the empirical part of the study and includes: a description of the organization and methods of the study and the results obtained by all the methods used (the 16-factor personal questionnaire of R. B. Kettel, the questionnaire "The level of subjective control" and the career guidance test to determine the propensity and interest in the profession of psychologist). A correlation and comparative analysis of the results of the study is also presented. In conclusion, the results of the theoretical and empirical parts of the work, as well as conclusions on the hypotheses put forward, are summarized, the practical significance of the study is justified and possible prospects for further development of this problem are described.
Alamedine, Dima. "Selection of EHG parameter characteristics for the classification of uterine contractions." Thesis, Compiègne, 2015. http://www.theses.fr/2015COMP2201/document.
Full textOne of the most promising biophysical markers of preterm labor is the electrical activity of the uterus, picked up on woman’s abdomen, the electrohysterogram (EHG). Several processing tools of the EHG signal (linear, nonlinear), allow the analysis of both excitability and propagation of the uterine electrical activity in order to differentiate between pregnancy contractions, which are ineffective, from labor effective contractions that might cause preterm birth. Therefore, on these multiple studies, the parameters being computed from different signal databases, obtained with different recording protocols, it is sometimes difficult to compare their results in order to choose the “best” parameter for preterm labor detection. Additionally, this large number of parameters increases the computational complexity for diagnostic purpose. Therefore, the main objective of this thesis is to select, among all the features of interest extracted from multiple studies, the most pertinent feature subsets in order to discriminate, on a given population, pregnancy and labor contractions. For this purpose, several methods for feature selection are tested. The first one, developed in this work, is based on the measurement of the Jeffrey divergence (JD) distance between the histograms of the parameters of the 2 classes, pregnancy and labor. The other are “Filter” and “Wrapper” Data Mining methods, extracted from the literature. In our work monovariate (in one given EHG channel) and bivariate analysis (propagation of EHG by measuring the coupling between channels) are used. The EHG signals are recorded using a multichannel system positioned on the woman’s abdomen for the simultaneous recording of 16 channels of EHG. Using all channels, for the monovariate, or all combinations of channels for the bivariate analysis, leads to a large dimension of parameters for each contraction. Therefore, another objective of our thesis is the selection of the best channels, for the monovariate, or best channel combinations, for the bivariate analysis, that provide the most useful information to discriminate between pregnancy and labor classes. This channel selection step is then followed by the feature selection for the channels or channel combinations selected. Additionally, we tested all our work using monopolar and bipolar signals.The results of this thesis permits us to evidence, when processing the EHG, which channels and features can be used with the best chance of success as inputs of a diagnosis system for discrimination between pregnancy and labor contractions. This could be further used for preterm labor diagnosis
Al-Roubaie, Zahra. "Human breast images : segmentation, analysis and conversion to electrical parameter profiles for Semcad-X electromagnetic simulator." Thesis, McGill University, 2008. http://digitool.Library.McGill.CA:80/R/?func=dbin-jump-full&object_id=116044.
Full textAl-Ballaa, Hind Rasheed. "Diagnosis via Qualitative parameter estimation." Thesis, University of Aberdeen, 2008. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.493495.
Full textBenešl, Lukáš. "Vliv fyzických parametrů a stáří silnoproudého vedení na výkonnost a spolehlivost PLC/BPL." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2020. http://www.nusl.cz/ntk/nusl-413002.
Full textGoitom, Asfaha Daniel. "Fundamental Studies on Direct Injection Nebulisers for Sample Introduction in ICP Spectrometry : Aerosol Properties, ICP Characteristics and Analytical Performance." Doctoral thesis, Umeå University, Chemistry, 2006. http://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-671.
Full textThe performance of different types of nebulisers: Vulkan direct injection nebuliser (Vulkan DIN), direct injection high efficiency nebuliser (DIHEN), microconcentric nebuliser coupled to cyclonic or double pass spray chamber (MCN-C or MCN-DP, respectively) was investigated and compared when used for sample introduction to ICP-MS or ICP-OES. With ICP-OES, in axial viewing mode, intensity distributions across the radius of the plasma (radial intensity profiles) were determined for different spectral lines with Esum 1.85-15.41 eV to determine fundamental plasma properties for various matrices using Vulkan DIN and MCN-C. The results showed that with the MCN-C the ionisation temperature (Tion) was about the same across the measured region of the plasma (±3.0 mm) whereas with the Vulkan DIN the Tion was significantly lower in the centre of the plasma. A large deviation from local thermodynamic equilibrium, as well as deteriorated stability, was observed for the plasma when using the Vulkan DIN.
With ICP-MS noise power spectra (NPS) were generated to identify sources of noise. NPS showed that the magnitude of white noise for the tested sample introduction systems decreased in the following order: Vulkan DIN > DIHEN > MCN-C > MCN-DP. This order follows the decrease of mean droplet size and span of the size distribution, indicating that the white noise is caused by spatial and temporal non-uniform desolvation and ionisation. Another source of noise arose from the peristaltic pump and the magnitude of pump interference noise decreased in the following order: DIHEN > MCN-C/DP > Vulkan DIN. Mains power interference noise and 1/f noise were lower for the direct injection nebulisers compared to the spray chamber systems. The contribution or effects of these noise components on relative standard deviations of steady-state ion-count rate and isotope ratio measurements is discussed in this thesis.
Aerosols generated by the Vulkan DIN and the DIHEN were also directly characterised using Particle Dynamic Analysis. The Vulkan DIN produced particles with a mean diameter of ~30 µm and a size distribution between 2-80 µm. With the DIHEN the corresponding values were ~11 µm and 1-40 µm, respectively, with a few particles at 55-78 µm. The mean velocity of particles from the Vulkan DIN was ~10 m s-1 and from the DIHEN ~18 m s-1. The lower velocity allows longer residence time counteracting the effects of the larger droplet size.
Lange, Yvonne. "Serologische Parameter in der Diagnostik der Post-ERCP-Pankreatitis." Doctoral thesis, Universitätsbibliothek Leipzig, 2011. http://nbn-resolving.de/urn:nbn:de:bsz:15-qucosa-64686.
Full textSilva, Leopoldo Magacho dos Santos. "Avaliação de parametros estruturais no diagnostico do glaucoma." [s.n.], 2004. http://repositorio.unicamp.br/jspui/handle/REPOSIP/310035.
Full textTese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas
Made available in DSpace on 2018-08-04T01:23:28Z (GMT). No. of bitstreams: 1 Silva_LeopoldoMagachodosSantos_D.pdf: 1066525 bytes, checksum: d1d302bd6421f23d5f4e474e23049056 (MD5) Previous issue date: 2004
Resumo: Objetivo: Avaliar a Sensibilidade e Especificidade de parâmetros estruturais (topografia de disco óptico e análise da camada de fibras nervosas da retina) no diagnóstico do glaucoma. Métodos: Pacientes com glaucoma primário de ângulo aberto foram selecionados do ambulatório de glaucoma da Unicamp. Indivíduos normais foram recrutados junto a voluntários dentro da equipe médica, amigos e parentes dos pacientes. Os participantes, após aprovação do Comitê de Ética da instituição, foram submetidos a exame oftalmológico completo, campimetria computadorizada (Humphrey Full Threshold, programa 24-2), topografia de disco óptico com o TOPSS e análise da camada de fibras nervosas da retina por meio da polarimetria de varredura a laser (GDx, versão 1.0.12). Curvas ROC foram criadas para se estabelecer novos pontos de corte para cada parâmetro individual de ambos os instrumentos. Em seguida, a análise de regressão multivariada foi empregada com parâmetros da topografia de disco óptico e polarimetria de varredura a laser separados e em conjunto para obter uma melhor relação sensibilidade/especificidade (Se/Es) no diagnóstico do glaucoma. Resultados: Cento e doze indivíduos com glaucoma e 88 normais foram incluídos. Os parâmetros individuais da polarimetria de varredura a laser com melhor capacidade em diferenciar olhos normais de glaucomatosos foram: The Number (Se: 79,5%, Es: 81,8%, área abaixo da curva ROC - aROC: 0,870), Maximum Modulation (Se: 83,0%, Es: 76,1%, aROC: 0,842) e Ellipse Modulation (Se: 65,2%, Es: 88,6%, aROC: 0,831), enquanto Average Disc Diameter (Se: 64%, Sp: 89%, aROC: 0.824), Total Disc Area (Se: 85%, Sp: 66%, aROC: 0.802) e Cup Area (Se: 69%, Sp: 85%, aROC: 0.797) foram os melhores parâmetros individuais da topografia de disco óptico. Entretanto, a análise discriminante apresentou melhores resultados que os parâmetros individuais, tanto para a polarimetria de varredura a laser (Se: 87,5%, Es: 86,4%, aROC: 0,900), topografia de disco óptico (Se: 90%, Sp: 81%, aROC: 0,910), quanto para a combinação de parâmetros derivados de ambos os instrumentos (Se: 93%, Es: 91%, aROC: 0,970). Conclusão: Parâmetros estruturais, avaliados pela topografia de disco óptico e pela polarimetria de varredura a laser apresentam boa capacidade na diferenciação entre olhos normais e glaucomatosos. Entretanto, os melhores resultados são obtidos ao combiná-los em uma função linear discriminante com parâmetros derivados de ambos os instrumentos
Abstract: Purpose: To test the ability of structural parameters (as measured by the Scanning Laser Polarimetry and Confocal Scanning Laser Ophthalmoscopy) to discriminate between normal and glaucomatous eyes. Methods: After approval of the Ethics Committee of the University of Campinas, primary open-angle glaucoma patients were selected from the glaucoma service. Normal individuals were recruited from volunteers among the medical staff, university members, family and friends of patients. All individuals underwent a thorough ophthalmic evaluation, a 24-2 full threshold Humphrey visual field, Scanning Laser Polarimetry with the GDx and Confocal Scanning Laser Ophthalmoscopy with the TOPSS. Cut-off points were selected and ROC curves were created for each individual Confocal Scanning Laser Ophthalmoscopy and Scanning Laser Polarimetry parameters. Finally, multivariate discriminant formulas were developed in order to achieve a better sensitivity (Se)/specificity (Sp) ratio for the diagnosis of glaucoma, initially separately for each device, and then combining parameters from Confocal Scanning Laser Ophthalmoscopy and Scanning Laser Polarimetry. Results: One-hundred and twelve patients with primary open-angle glaucoma and 88 normal individuals were enrolled in the study. The best Scanning Laser Polarimetry parameters in differentiating normal individuals from glaucoma patients were: The Number (Se: 79,5%, Es: 81,8%, area under the ROC curve- aROC: 0,870), Maximum Modulation (Se: 83,0%, Es: 76,1%, aROC: 0,842) and Ellipse Modulation (Se: 65,2%, Es: 88,6%, aROC: 0,831), while the best Confocal Scanning Laser Ophthalmoscopy individual parameters were: Average Disc Diameter (Se: 64%, Sp: 89%, aROC: 0,824), Total Disc Area (Se: 85%, Sp: 66%, aROC: 0,802) and Cup Area (Se: 69%, Sp: 85%, aROC: 0,797). However, the multivariate analysis resulted in better results for the Scanning Laser Polarimetry (Se: 87,5%, Es: 86,4%, aROC: 0,900), Confocal Scanning Laser Ophthalmoscopy (Se: 90%, Sp: 81%, aROC: 0,910), and for the combination of parameters from both devices (Se: 93%, Es: 91%, aROC: 0,970). Conclusion: Structural parameters, as measured by the Confocal Scanning Laser Ophthalmoscopy and Scanning Laser Polarimetry have good ability to differentiate normal individuals from glaucoma patients. However, better results are obtained combining parameters from both devices in a multivariate discriminant formula
Doutorado
Oftalmologia
Doutor em Ciências Médicas
Thuillier, Philippe. "Optimisation des paramètres de quantification en imagerie TEP pour le diagnostic, l'évaluation thérapeuthique et le pronostic des cancers endocriniens Malignancy rate of focal thyroid incidentaloma detected by FDG PET–CT: results of a prospective cohort study, in Endocrine Connections 6(6), 2017 Diagnostic Value of FDG PET-CT Quantitative Parameters and Deauville-Like 5 Point-Scale in Predicting Malignancy of Focal Thyroid Incidentaloma, in Frontiers in Medicine 6(24), February 2019." Thesis, Brest, 2019. http://www.theses.fr/2019BRES0088.
Full textThe objective of this work was to propose a systematic and reasoned approach of the quantification tools available in clinical routine and in research in the management of patients with endocrine tumors. Our results report the limitations of semi-quantitative parameters to assess the malignancy of fTI detected by 18FDG-PET / CT. Our data on the interest of textural parameters in the diagnosis of malignancy of adrenal tumors show excellent performances of these indices. However these indices do not appear superior in comparison with conventional semi-quantitative parameters.Our approach raises new hypotheses regarding the interest of texture analysis in the characterization of some rare adrenal tumors (pheochromocytomas and adrenocortical carcinoma) that will be the subject of future work. Finally, our work on the multi-parametric 68Ga-DOTATOC-PET / CT imaging highlights the feasibility of a whole-body dynamic 68Ga-DOTATOC-PET / CT acquisition and the possibilities to perform quantification of NETs uptake treated with PRRT on post-therapeutic SPECT / CT acquisitions. Our results open up multiple perspectives for the management of NETs at different stages of the disease (diagnosis, prognosis and therapeutic evaluation)
Sandink, Christopher Albert. "Screening diagnostics for parameter selection in extended Kalman filter implementations." Thesis, National Library of Canada = Bibliothèque nationale du Canada, 2000. http://www.collectionscanada.ca/obj/s4/f2/dsk1/tape3/PQDD_0006/MQ45297.pdf.
Full text許自豪 and Chi-ho Geo Hui. "New laboratory parameters in the diagnosis of iron-restricted erythropoiesis." Thesis, The University of Hong Kong (Pokfulam, Hong Kong), 2008. http://hub.hku.hk/bib/B40722089.
Full textHui, Chi-ho Geo. "New laboratory parameters in the diagnosis of iron-restricted erythropoiesis." Click to view the E-thesis via HKUTO, 2008. http://sunzi.lib.hku.hk/hkuto/record/B40722089.
Full textRatushna, Vladyslava G. "Incorporation of Physico-Chemical Parameters Into Design of Microarray Experiments." Thesis, Virginia Tech, 2005. http://hdl.handle.net/10919/32989.
Full textMaster of Science
Guo, Fei. "MULTI-PARAMETER PHYSIOLOGICAL TRACKING SYSTEM FOR DIAGNOSIS OF SEPSIS." Case Western Reserve University School of Graduate Studies / OhioLINK, 2021. http://rave.ohiolink.edu/etdc/view?acc_num=case1613129350013438.
Full textSchreier, Jan. "Vliv parametrů vazebného média a struktury povrchu na kvalitu snímaného signálu akustické emise." Master's thesis, Vysoké učení technické v Brně. Fakulta strojního inženýrství, 2012. http://www.nusl.cz/ntk/nusl-230124.
Full textBrowne, R. Edwin. "An evaluation of 'Coast Down Time' as a diagnostic parameter for condition monitoring." Thesis, Glasgow Caledonian University, 2008. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.486489.
Full textLemaréchal, Jean-Didier. "Estimation des propriétés dynamiques des réseaux cérébraux à large échelle par modèles de masse neurale de potentiels évoqués cortico-corticaux Comparison of two integration methods for dynamic causal modeling of electrophysiological data. NeuroImage An atlas of neural parameters based on dynamic causal modeling of cortico-cortical evoked potentials." Thesis, Université Grenoble Alpes, 2020. http://www.theses.fr/2020GRALS007.
Full textThis thesis work aims at modeling cortico-cortical evoked potentials (CCEPs) induced by intracortical direct electrical stimulation in epileptic patients being recorded with stereo-electroencephalography during epilepsy surgery. Neural mass models implemented within the dynamic causal modeling (DCM) framework are used for this purpose.We first demonstrate the importance of using an accurate integration scheme to solve the system of differential equations governing the global dynamics of the model, in particular to obtain precise estimates of the neuronal parameters of the model (Lemaréchal et al., 2018).In a second study, this methodology is applied to a large dataset from the F-TRACT project. The axonal conduction delays and speeds between brain regions, as well as the local synaptic time constants are estimated and their spatial mapping is obtained based on validated cortical parcellation schemes. Interestingly, the large amount of data included in this study allow to highlight brain dynamics differences between the young and the older populations (Lemaréchal et al., submitted).Finally, in the Bayesian context of DCM, we show that an atlas of connectivity can improve the specification and the estimation of a neural mass model, for electroencephalographic and magnetoencephalographic studies, by providing a priori distributions on the connectivity parameters of the model.To sum up, this work provides novel insights on dynamical properties of cortico-cortical interactions. The publication of our results in the form of an atlas of neuronal properties already provides an effective tool for a better specification of whole brain neuronal models
Schostak, Martin Jürgen Wolfgang [Verfasser]. "Neue Parameter in der molekularen Diagnostik des Prostatakarzinoms / Martin Jürgen Wolfgang Schostak." Berlin : Medizinische Fakultät Charité - Universitätsmedizin Berlin, 2007. http://d-nb.info/1022577883/34.
Full textChamuleau, Steven Anton Jozef. "Intracoronary derived physiological parameters for clinical decision-making in patients with multi-vessel coronary artery disease." [S.l. : Amsterdam : s.n.] ; Universiteit van Amsterdam [Host], 2001. http://dare.uva.nl/document/85068.
Full textAli, Ali Alawi. "Real time fault diagnosis using observer and physical parameter estimation." Thesis, National Library of Canada = Bibliothèque nationale du Canada, 1997. http://www.collectionscanada.ca/obj/s4/f2/dsk2/ftp01/MQ29966.pdf.
Full textPoshtan, Javad. "A geometric alignment approach to parameter-estimation-based fault diagnosis." Thesis, National Library of Canada = Bibliothèque nationale du Canada, 1997. http://www.collectionscanada.ca/obj/s4/f2/dsk2/ftp02/NQ29470.pdf.
Full textChen, Xiaoming. "The development of a parameter estimation tool towards fault diagnosis." The Ohio State University, 1997. http://rave.ohiolink.edu/etdc/view?acc_num=osu1399563299.
Full textFeng, Ming-Fa. "Fault diagnosis and prediction in reciprocating air compressors by quantifying operating parameters." Diss., Virginia Tech, 1992. http://hdl.handle.net/10919/39786.
Full textPh. D.