To see the other types of publications on this topic, follow the link: Digital protective relays.

Dissertations / Theses on the topic 'Digital protective relays'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 31 dissertations / theses for your research on the topic 'Digital protective relays.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.

1

Liang, Feng. "Performance enhancement of digital relays for transmission line distance protection /." Internet access available to MUN users only, 2003. http://collections.mun.ca/u?/theses,153681.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Gabriel, Janio Denis. "Desenvolvimento do protótipo de um relé digital para geração distribuída com integração para redes inteligentes." Universidade Tecnológica Federal do Paraná, 2013. http://repositorio.utfpr.edu.br/jspui/handle/1/608.

Full text
Abstract:
Com novas normas, incentivos governamentais e preocupação com questões ambientais, é esperado um crescimento no número de unidades de geradoras conectadas a rede a partir dos consumidores. Algumas questões técnicas relacionadas à elevada penetração de geração distribuída nos alimentadores de distribuição preocupam as concessionárias de energia, as quais buscam meios de prevenir possíveis efeitos indesejados no sistema elétrico. Esta pesquisa apresenta o desenvolvimento de um relé digital aplicado à proteção da conexão de geração distribuída na rede elétrica, com foco em microgeração e minigera
APA, Harvard, Vancouver, ISO, and other styles
3

Cho, Sungmin. "Modeling and testing of digital protection relay for an induction motor." Thesis, Cho, Sungmin (2010) Modeling and testing of digital protection relay for an induction motor. Other thesis, Murdoch University, 2010. https://researchrepository.murdoch.edu.au/id/eprint/4117/.

Full text
Abstract:
The project details the modelling of the induction motor SEL701 Relay in PowerFactory. In order to prove operational reliability, both off-line and on-line testing were implemented to verify the characteristic curve of the relay by measuring trip times. Prior to modelling the relay, the thermal limit curves of the motor were studied to scheme the motor protection relay. In addition, the requirement of motor protection is discussed and the elements of a protection relay corresponding to the requirements are presented. The results indicate that the off-line (simulation) and on-line test have con
APA, Harvard, Vancouver, ISO, and other styles
4

Gheralde, André Luiz Junqueira. "Aplicação de relés adaptativos na proteção digital à distância." Universidade de São Paulo, 1996. http://www.teses.usp.br/teses/disponiveis/18/18133/tde-25012018-121313/.

Full text
Abstract:
O objetivo deste trabalho é o desenvolvimento de \"software\" para proteção digital das linhas de transmissão. Com esse propósito são implementados relés de distância com características quadrilaterais e adaptativas. Um \"software\" básico para este fim consiste de várias etapas como: detecção da falta, filtragem digital, classificação da falta, cálculo da impedância aparente e verificação das zonas de proteção. Na etapa de filtragem digital das ondas, é utilizada a Transformada Discreta de Fourier (TDF) para a extração dos componentes fundamentais de tensão e corrente. A característica quadri
APA, Harvard, Vancouver, ISO, and other styles
5

Navarro, Eduardo Coelho. "Proteção diferencial digital de linhas de transmissão com compensação série." Universidade de São Paulo, 2002. http://www.teses.usp.br/teses/disponiveis/18/18133/tde-05062017-091546/.

Full text
Abstract:
A proteção diferencial é o esquema preferido para proteção de equipamentos e linhas de transmissão. A proteção diferencial exige que informações de todos terminais de zona sob proteção sejam usados para calcular a corrente diferencial. Se esta corrente excede um determinado limite significa que uma falta pode existir na zona protegida. Tais cálculos devem ser executados em cada terminal, consequentemente deve existir um rápido canal de comunicação entre todos os terminais de linha. Este trabalho apresenta o desenvolvimento do algoritmo de uma proteção diferencial digital de linhas de transmiss
APA, Harvard, Vancouver, ISO, and other styles
6

Silva, Kathiane Queiroz da. "Sistema de proteÃÃo adaptativa." Universidade Federal do CearÃ, 2014. http://www.teses.ufc.br/tde_busca/arquivo.php?codArquivo=13929.

Full text
Abstract:
Conselho Nacional de Desenvolvimento CientÃfico e TecnolÃgico<br>This paper proposes an adaptive protection system (SPA) developed in Matlab, in order to make the smart grid for greater flexibility reliability and security of the electric power system the protection system proposed is able to assist in the study of protection by the choice of settings to be entered in the relay once the mains relays are parameterized adaptive protection is responsible for discerning between a change of setting group or send new settings this decision is taken by the SPA in the control center and sent to the gr
APA, Harvard, Vancouver, ISO, and other styles
7

Velásquez, Omar Chayña Chayña. "Ajuste e ensaio de sistemas de proteção de geradores síncronos." Universidade de São Paulo, 2015. http://www.teses.usp.br/teses/disponiveis/3/3143/tde-13062016-090911/.

Full text
Abstract:
Os sistemas de proteção dos elementos da rede elétrica desempenham um papel de fundamental importância na segurança e confiabilidade dos sistemas de potência. A não atuação ou a atuação incorreta dos relés de proteção durante uma falta localizada em um componente da rede pode transformar-se em um evento sistêmico de grandes proporções (blecaute). Esses eventos trazem riscos e elevados prejuízos econômicos à sociedade. A proteção dos geradores síncronos, apesar do alto custo e complexidade deste tipo de equipamento, não recebe a mesma atenção na literatura que a dedicada à proteção de outros el
APA, Harvard, Vancouver, ISO, and other styles
8

Queiroz, Alan Rômulo Silva. "Utilização de relés digitais para mitigação dos riscos envolvendo arco elétrico." Universidade de São Paulo, 2011. http://www.teses.usp.br/teses/disponiveis/3/3143/tde-30052012-124531/.

Full text
Abstract:
O trabalho tem como objetivo avaliar e propor a utilização de soluções tecnológicas que permitam a redução dos riscos causados por arcos elétricos nas instalações de uma unidade industrial com sistema isolado de geração elétrica. Por ser extremamente danosa à segurança das pessoas que interagem com uma instalação elétrica e por causar danos significativos aos equipamentos e instalações, a energia incidente, proveniente de um arco elétrico, deve ser mensurada em conformidade com as normas existentes e os riscos devem ser controlados e mitiga
APA, Harvard, Vancouver, ISO, and other styles
9

Dias, Ozenir Farah da Rocha 1988. "Implementação do religamento monopolar adaptativo rápido baseado na assinatura harmônica de tensão no simulador digital em tempo real (RTDS)." [s.n.], 2015. http://repositorio.unicamp.br/jspui/handle/REPOSIP/259596.

Full text
Abstract:
Orientador: Maria Cristina Dias Tavares<br>Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação<br>Made available in DSpace on 2018-08-27T00:34:34Z (GMT). No. of bitstreams: 1 Dias_OzenirFarahdaRocha_M.pdf: 5023742 bytes, checksum: b0fe9b9418551d927583a884fbec6e92 (MD5) Previous issue date: 2015<br>Resumo: Este trabalho apresenta a implementação de um esquema de religamento monopolar adaptativo rápido baseado na medição do conteúdo harmônico da tensão da fase aberta nas extremidades da linha de transmissão. O objetivo principal deste es
APA, Harvard, Vancouver, ISO, and other styles
10

Bulgarelli, Roberval. "Proteção térmica de motores de indução trifásicos industriais." Universidade de São Paulo, 2006. http://www.teses.usp.br/teses/disponiveis/3/3143/tde-01122006-134918/.

Full text
Abstract:
Em função das limitações apresentadas pelos relés eletromecânicos, a proteção térmica de motores foi historicamente tratada como um problema de coordenação de sobrecorrente, sem levar em consideração a dinâmica e o histórico térmico envolvido na operação contínua do motor. Os atuais relés microprocessados para proteção de motores implementam equações diferenciais de primeira ordem, cujos algoritmos, processados em tempo real, possibilitam uma nova abordagem para uma adequada proteção térmica, utilizando modelos matemáticos. Especialmente para os motores industriais de grande porte e de maior i
APA, Harvard, Vancouver, ISO, and other styles
11

Vargas, Elis Tápia. "Uma proposta de relé digital de freqüência baseado em algoritmos genéticos." Universidade de São Paulo, 2005. http://www.teses.usp.br/teses/disponiveis/18/18133/tde-17112006-112206/.

Full text
Abstract:
Este trabalho apresenta um método baseado em algoritmos genéticos – AGs, o qual consiste na estimação dos parâmetros associados as formas de ondas, tais como amplitude, freqüência e ângulo de fase das mesmas, referentes a uma proposição de relé de freqüência. O método proposto é baseado em algoritmos genéticos com representação real, tendo em vista a não necessidade de codificação dos valores logo na entrada do processo. O objetivo do trabalho é apresentar um estudo de uma das várias técnicas da computação evolutiva, conhecida como AG, cuja aplicação é inspirada nos mecanismos da evolução natu
APA, Harvard, Vancouver, ISO, and other styles
12

Soares, Antonio Helson Mineiro. "Metodologia computacional para coordenação automática de dispositivos de proteção contra sobrecorrente em sistemas elétricos industriais." Universidade de São Paulo, 2009. http://www.teses.usp.br/teses/disponiveis/18/18154/tde-17112009-090033/.

Full text
Abstract:
Este trabalho apresenta uma metodologia computacional para coordenação automática de dispositivos de proteção contra sobrecorrente em sistemas elétricos industriais radiais, tendo como principais vantagens a exatidão nos cálculos dos ajustes e a proposição automática de soluções para eventuais problemas de coordenação, sempre que possível. A metodologia é utilizada tanto para proteção individual contra sobrecorrente dos equipamentos quanto para coordenação dos dispositivos de proteção do sistema. É feito um estudo detalhado dos requisitos de proteção de sobrecorrente dos equipamentos empregado
APA, Harvard, Vancouver, ISO, and other styles
13

Bernardes, Alexandre Paciencia. "Um esquema completo de proteção diferencial de transformadores para testes em um relé digital." Universidade de São Paulo, 2006. http://www.teses.usp.br/teses/disponiveis/18/18154/tde-16072006-122259/.

Full text
Abstract:
Este trabalho apresenta um procedimento completo de simulação da proteção digital diferencial aplicada a transformadores de potência, visando o emprego deste à avaliação do comportamento de relés comercialmente disponíveis. Foi escolhido o software ATP (Alternative Transients Program) como ferramenta para a simulação de distintas situações sobre um sistema diferencial de proteção aplicado a um transformador de 25 MVA. Dentre as ocorrências evidenciadas, destacam-se: situações de faltas internas, faltas externas, situações de energização e energização com falta interna do transformador, condiçã
APA, Harvard, Vancouver, ISO, and other styles
14

Shah, Syed Arif Ullah. "The impacts of series compensated EHV lines on distance protection, and a proposed new mitigation solution." Thesis, KTH, Elektroteknisk teori och konstruktion, 2017. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-209916.

Full text
Abstract:
Series compensation is extensively applied to the transmission lines to increase the power transfer capability of transmission lines, reduce transmission losses, improve voltage profiles, and improve power oscillation damping and transient stability of power systems. But it modifies the apparent impedance of the transmission lines during fault conditions and might cause the distance protection of transmission lines to encounter directional discrimination issues and reach problems. The non-linear characteristic of metal oxide varistor in series compensation model creates further complexity to t
APA, Harvard, Vancouver, ISO, and other styles
15

Netto, Ulisses Chemin. "Aplicações de controle e supervisão distribuídas em subestações de energia elétrica através do uso de relés digitais de proteção." Universidade de São Paulo, 2008. http://www.teses.usp.br/teses/disponiveis/18/18154/tde-16042008-144037/.

Full text
Abstract:
Na primeira década deste século os equipamentos de proteção com tecnologia digital sinalizaram um novo paradigma para a composição dos sistemas de proteção. É fato também que essa tecnologia convive com suas antecessoras, que por força de sua longa predominância ainda exercem alguma influência sobre o pensamento, concepção e operação dos sistemas de proteção. Esses novos equipamentos multifunções, em geral, estão subutilizados, sendo o seu potencial ainda não empregado ou explorado em profundidade. Os relés digitais possuem grande capacidade para resolver alguns dos problemas intrínsecos aos s
APA, Harvard, Vancouver, ISO, and other styles
16

Magrin, Fabiano Gustavo Silveira 1978. "Modelagem de um relé de proteção diferencial de transformador no RTDS." [s.n.], 2014. http://repositorio.unicamp.br/jspui/handle/REPOSIP/259599.

Full text
Abstract:
Orientador: Maria Cristina Dias Tavares<br>Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação<br>Made available in DSpace on 2018-08-25T04:21:56Z (GMT). No. of bitstreams: 1 Magrin_FabianoGustavoSilveira_M.pdf: 5471875 bytes, checksum: 204630879d78c9f5167f324d6d0f5fe9 (MD5) Previous issue date: 2014<br>Resumo: Devido à dificuldade de execução de testes em sistemas reais os engenheiros procuram ferramentas e modelos para simular ou emular os sistemas reais em laboratório. Nesse sentido, o objetivo deste projeto de pesquisa foi desenvol
APA, Harvard, Vancouver, ISO, and other styles
17

Miranda, Juliano Coêlho. "IEC-61850: interoperabilidade e intercambialidade entre equipamentos de supervisão, controle e proteção através das redes de comunicação de dados." Universidade de São Paulo, 2009. http://www.teses.usp.br/teses/disponiveis/18/18154/tde-16062009-102211/.

Full text
Abstract:
Os sistemas de comunicação de dados sempre foram considerados um fator crítico na operação em tempo real do sistema elétrico de potência, devido a necessidade de decisões rápidas e precisas em pontos geograficamente distribuídos, desde usinas geradoras de energia até interfaces de usuários. Com a tecnologia digital, as medições, sinalizações e comandos são encapsulados em pacotes de dados que trafegam na rede da subestação, utilizando protocolos que estabelecem os formatos, as regras, os métodos, negociando e concordando no uso de parâmetros, que assegurem o transporte de informações entre doi
APA, Harvard, Vancouver, ISO, and other styles
18

NASCIMENTO, Jamile Pinheiro. "Um algoritmo de proteção adaptativa para sistemas de distribuição com inserção de geração distribuída." Universidade Federal de Campina Grande, 2014. http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/444.

Full text
Abstract:
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-04-20T22:58:46Z No. of bitstreams: 1 JAMILE PINHEIRO NASCIMENTO - DISSERTAÇÃO PPGEE 2014..pdf: 2146495 bytes, checksum: e397e112357d55c0badad1a62f5324cf (MD5)<br>Made available in DSpace on 2018-04-20T22:58:46Z (GMT). No. of bitstreams: 1 JAMILE PINHEIRO NASCIMENTO - DISSERTAÇÃO PPGEE 2014..pdf: 2146495 bytes, checksum: e397e112357d55c0badad1a62f5324cf (MD5) Previous issue date: 2014-08<br>Um algoritmo de proteção adaptativa para solucionar o problema da proteção de sistemas com geração distribuída é proposto. O algoritmo mo
APA, Harvard, Vancouver, ISO, and other styles
19

CAMPOS, Alana Kelly Xavier Santos. "Um novo método de estimação fasorial para uso em relés digitais de proteção." Universidade Federal de Campina Grande, 2016. http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/582.

Full text
Abstract:
Submitted by Emanuel Varela Cardoso (emanuel.varela@ufcg.edu.br) on 2018-05-04T19:00:50Z No. of bitstreams: 1 ALANA KELLY XAVIER SANTOS CAMPOS – TESE (PPGEE) 2016.pdf: 5517354 bytes, checksum: 24306600f8b9a28a2d230c48b0811a3a (MD5)<br>Made available in DSpace on 2018-05-04T19:00:50Z (GMT). No. of bitstreams: 1 ALANA KELLY XAVIER SANTOS CAMPOS – TESE (PPGEE) 2016.pdf: 5517354 bytes, checksum: 24306600f8b9a28a2d230c48b0811a3a (MD5) Previous issue date: 2016-10-21<br>Capes<br>Um método de estimação fasorial é proposto para ser utilizado em relés digitais de proteção. Este método tem o
APA, Harvard, Vancouver, ISO, and other styles
20

Cesar, Eduardo Lenz. "Sistemas inteligentes aplicados à coordenação da proteção de sistemas elétricos industriais com relés digitais." Universidade do Estado do Rio de Janeiro, 2013. http://www.bdtd.uerj.br/tde_busca/arquivo.php?codArquivo=8023.

Full text
Abstract:
Atualmente existem diferentes ferramentas computacionais para auxílio nos estudos de coordenação da proteção, que permitem traçar as curvas dos relés, de acordo com os parâmetros escolhidos pelos projetistas. Entretanto, o processo de escolha das curvas consideradas aceitáveis, com um elevado número de possibilidades e variáveis envolvidas, além de complexo, requer simplificações e iterações do tipo tentativa e erro. Neste processo, são fatores fundamentais tanto a experiência e o conhecimento do especialista, quanto um árduo trabalho, sendo que a coordenação da proteção é qualificada pela IEE
APA, Harvard, Vancouver, ISO, and other styles
21

Váhala, Václav. "Nastavení ochranných funkcí pro zadanou rozvodnu VN." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2017. http://www.nusl.cz/ntk/nusl-316922.

Full text
Abstract:
The thesis is focused on the protection concept for medium voltage substation. The first theoretical part of thesis describes given medium voltage substation. Substation consists of two incoming feeders and six outgoing feeders. Due to the size of the substation was selected one outgoing feeder which is the subject of description and protection concept. Next part of the thesis is a description of the protective functions used to protect the elements in the selected feeder. This part contains a detailed description of the function and setting options for protection. The main part of the thesis
APA, Harvard, Vancouver, ISO, and other styles
22

Silva, Lazaro Eduardo da. "Tecnologias WEB aplicadas aos sistemas elétricos de potência." Universidade de São Paulo, 2010. http://www.teses.usp.br/teses/disponiveis/18/18154/tde-04102010-153801/.

Full text
Abstract:
A utilização de equipamentos digitais e de meios de comunicação de dados, na conexão entre os dispositivos de uma subestação de energia elétrica oportunizam o uso de tecnologias para aprimorar e elevar as potencialidades de controle e supervisão do sistema elétrico de potência. As concessionárias de energia elétrica demandam altos investimentos na construção e implantação de sistemas de supervisão, controle e aquisição de dados. A partir destes sistemas é possível visualizar em um mapa da rede elétrica, os pontos de instalação dos relés e os status do seu funcionamento, possibilitando a concre
APA, Harvard, Vancouver, ISO, and other styles
23

Liao, Wen-Bin, and 廖文彬. "A digital multifunction protective relay." Thesis, 1993. http://ndltd.ncl.edu.tw/handle/87035311644414203530.

Full text
APA, Harvard, Vancouver, ISO, and other styles
24

Nayak, Stutee, and Manisha Swain. "Design of CORDIC-based Digital Protective Relay." Thesis, 2013. http://ethesis.nitrkl.ac.in/4816/1/109EC0246.pdf.

Full text
Abstract:
Protective relays are used to show the current status of a given power system. It is used to determine whether parameters like voltage or current violate any trip or reset specification or condition. In this project, overcurrent time invariant model of protective relay is implemented using CORDIC algorithm. Here we use CORDIC algorithm to implement the relay flowchart. All of the arithmetic calculations and relaying algorithms can be managed by a CORDIC processor. As CORDIC algorithm is simple to implement, it has a very low FPGA footprint and it negates any need of multipliers as well. In thi
APA, Harvard, Vancouver, ISO, and other styles
25

Hong, Pei-Lun, and 洪培倫. "Digital Integrated Circuit Design of DC-offset Removal Scheme for Protective Relay." Thesis, 2004. http://ndltd.ncl.edu.tw/handle/68441448603617264927.

Full text
Abstract:
碩士<br>國立臺灣大學<br>電機工程學研究所<br>92<br>In this thesis, we design a chip to implement DC-offset removal scheme, and then we use FPGA to verify the function of our circuit for proving its availability. By Bottom-Up design style, we divide this system to three parts. First part is FCDFT module, and we adopt Pipeline concept to accomplish it. Second part is complex number computing module, and we develop a “re-normalization” scheme to improve precision. Last part is CORDIC module, and we use it for transferring rectangular coordinate to polar coordinate. About its result, the error rate of baseband amp
APA, Harvard, Vancouver, ISO, and other styles
26

Lu, Ying-Chen, and 陸映辰. "Research and Development on Low Voltage Microgrid Digital Protection Relay." Thesis, 2014. http://ndltd.ncl.edu.tw/handle/16533277264340327821.

Full text
Abstract:
碩士<br>中原大學<br>電機工程研究所<br>102<br>Abstract This study intends to develop a digital relay suitable for low voltage microgrid, and conducting tests for protect method and building relay prototype on Institute of Nuclear Energy Research (INER ) Microgrid which serves as a test platform . When microgrid have fault occurs,the digital relay developed in this research can continue to operate without interruption at non-fault zones and must adapt to the unstable output of renewable resource.The digital relay cotain two characteristics(1)when fault occurs this relay must detect the fault and isolate the
APA, Harvard, Vancouver, ISO, and other styles
27

Chen, Chien-Yu, and 陳建宇. "Design of a FPGA-based Digital Relay for Anti-islanding Protection." Thesis, 2007. http://ndltd.ncl.edu.tw/handle/27bvau.

Full text
Abstract:
碩士<br>國立臺灣科技大學<br>電機工程系<br>95<br>This thesis presents the development of a FPGA-based SOC islanding relay for wind power generation system with islanding detection functions. In software, we use the latest detection algorithms to design IP of islanding relay, such as over/under voltage, over current, over/under frequency, rate of change of frequency and vector jump. Also using ModelSim to simulate the action of the relay IP that ensure the accuracy of the timing and function. In hardware, the major tasks are develop an A/D converter and peripheral controller IP. Finally, To setup a prototype F
APA, Harvard, Vancouver, ISO, and other styles
28

Lin, Feng-Li, and 林峰立. "SIP Developments and SOC Implementations for Multi-Functional Digital Protection Relays in Power Systems." Thesis, 2004. http://ndltd.ncl.edu.tw/handle/59827655341204645461.

Full text
Abstract:
碩士<br>長庚大學<br>電機工程研究所<br>92<br>A method of designing a multi-functional digital protective relay chip with the concepts of using SIP cores is proposed. The protective relay includes functions of over-current/under-current relays,over-voltage /under-voltage relays, frequency detection, and an RS232 interface.Comparing with existing microprocessor designs, in general,SoC designs have the following well-known advantages, such as lower cost;lower design complexity; higher reliability, higher operating speed,and better integration. The aim of our work is to define and implement each req
APA, Harvard, Vancouver, ISO, and other styles
29

KAI, SHYU SHIEN, and 徐鉉凱. "Digital Directional Overcurrent Relays Applied in the Optimal Protection of Transmission Lines of Coordination Strategy." Thesis, 2012. http://ndltd.ncl.edu.tw/handle/38795957617947751199.

Full text
Abstract:
碩士<br>國立臺灣科技大學<br>電機工程系<br>100<br>Directional overcurrent relays are widely used in power complex loop network. Coordination process, consider the network system change and to meet the variety of coordination norms and restrictions, the relay engineers often spend a lot of time to calculate the power relay standard configuration settings. This thesis focuses on the directional over current relay to the optimal settings a comprehensive set of methods to solve the optimal settings in different networks. The graph theory algorithms based on the high-capacity power supply are proposed, to decided
APA, Harvard, Vancouver, ISO, and other styles
30

Lin, Shih-Che, and 林士哲. "Fundamental System Frequency Detection and Flicker Analysis Mechanism for Intelligent Electronic Devices and Digital Protection Relays." Thesis, 2013. http://ndltd.ncl.edu.tw/handle/14445518048256812265.

Full text
Abstract:
碩士<br>國立中正大學<br>電機工程研究所<br>101<br>With the widespread use of nonlinear loads in the power system, pollutions of power quality have become serious. Besides, the power unbalance between the generation and the load demand would make the fundamental frequency varying with time. These disturbances may introduce operational problems of power system equipment. When a fault occurs, the protection relay will be fast operated. Then, the protection relays will isolate the faulted zone to reduce the extent of damage to the equipment so that the power system remains stable and protects the safety of the sy
APA, Harvard, Vancouver, ISO, and other styles
31

Banitalebi, Dehkordi Ali. "Improved models of electric machines for real-time digital simulation." 2010. http://hdl.handle.net/1993/3935.

Full text
Abstract:
This thesis advances the state of the art in modeling electric machines in electro-magnetic transient simulation programs, particularly in real-time digital simulators. A new tool, developed in this thesis, expands the application of real-time digital simulators to closed-loop testing of protection relays designed to protect synchronous machines during internal faults. To evaluate the inductances of synchronous machines, a winding function approach was developed in this thesis which is capable of taking into account both the actual distribution of windings and the shape of the pole-arc. Fact
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!