To see the other types of publications on this topic, follow the link: Dosimetric gel.

Dissertations / Theses on the topic 'Dosimetric gel'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 50 dissertations / theses for your research on the topic 'Dosimetric gel.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.

1

Pavoni, Juliana Fernandes. "Dosimetria tridimensional por imagens de ressonância magnética com gel MAGIC modificado." Universidade de São Paulo, 2009. http://www.teses.usp.br/teses/disponiveis/59/59135/tde-27042010-171038/.

Full text
Abstract:
Os avanços nas técnicas de tratamento com radiação ionizante estão gerando distribuições de dose muito complexas que precisam ser verificadas antes da aplicação do tratamento no paciente. Diversos dosímetros já foram propostos para esta verificação, mas o que vem apresentando os melhores resultados são os géis poliméricos que permitem a visualização tridimensional da dose. Neste trabalho desenvolvemos um gel dosimétrico do tipo MAGIC com componentes nacionais, para baratear o custo e assim, facilitar a sua aplicação na rotina clínica. Nós adicionamos formaldeído ao gel para aumentar seu ponto
APA, Harvard, Vancouver, ISO, and other styles
2

Petchevist, Paulo Cesar Dias. "Comissionamento dos parâmetros físicos dosimétricos em aceleradores lineares clínicos usando o dosímetro FXG." Universidade de São Paulo, 2015. http://www.teses.usp.br/teses/disponiveis/59/59135/tde-21072015-101409/.

Full text
Abstract:
A International Comission on Radiation Units and Measurements (ICRU) recomenda que a incerteza total de um tratamento radioterápico não deva ultrapassar de 5%, ou seja, cada etapa do processo de entrega da dose absorvida ao volume alvo do paciente tenha incerteza menor que esse valor (ICRU 50, 1993; ICRU 62, 1999). O cuidado com essas incertezas inicia-se na instalação da máquina (neste caso, de um Acelerador Linear Clínico), passando pela sua aceitação, pelo comissionamento, perdurando nos controles de qualidade posteriores e até em novos comissionamentos, se necessários. Os parâmetros físic
APA, Harvard, Vancouver, ISO, and other styles
3

Sakuraba, Roberto Kenji. "Desenvolvimento de um sistema de verificação dosimétrica tridimensional utilizando Solução Fricke gel na aplicação para a verificação da Radioterapia em Arco Modulado Volumétrico (VMAT) nos tratamentos com movimentação do alvo pela respiração." Universidade de São Paulo, 2015. http://www.teses.usp.br/teses/disponiveis/85/85131/tde-03032016-091027/.

Full text
Abstract:
A Radioterapia em arco modulado volumétrico (VMAT) é uma das modalidades mais avançadas em teleterapia para o tratamento de câncer. Os diversos avanços tecnológicos, bem como a evolução das técnicas de tratamento tornaram o VMAT como uma das modalidades de estado da arte para o tratamento de alguns cânceres. Parte deste avanço é creditada à melhoria na acurácia e na prescrição de dose absorvida recomendada ao paciente ao longo dos anos. Este avanço permite que atualmente seja possível realizar os cálculos dosimétricos, por meio de sistemas de planejamento computadorizado, considerando as heter
APA, Harvard, Vancouver, ISO, and other styles
4

MANGUEIRA, THYAGO F. "Avaliacao dosimetrica da solucao fricke gel usando a tecnica de espectrofotometria para aplicacao na dosimetria de eletrons e neutrons." reponame:Repositório Institucional do IPEN, 2009. http://repositorio.ipen.br:8080/xmlui/handle/123456789/9447.

Full text
Abstract:
Made available in DSpace on 2014-10-09T12:26:53Z (GMT). No. of bitstreams: 0<br>Made available in DSpace on 2014-10-09T14:00:05Z (GMT). No. of bitstreams: 0<br>Dissertacao (Mestrado)<br>IPEN/D<br>Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
APA, Harvard, Vancouver, ISO, and other styles
5

Atkins, Timothy John. "Investigation of ultrasonic properties of MAGIC gels for pulse-echo gel dosimetry." Thesis, University of Southampton, 2014. https://eprints.soton.ac.uk/371793/.

Full text
Abstract:
This thesis describes investigations into the design and evaluation of novel ultrasonic methods for 3-dimensional ionising radiation dose verification. Pulse-echo ultrasound methods were investigated for the measurement and analysis of complex radiation therapy dose delivery. The physical properties of MAGIC (Methacrylic and Ascorbic acid in Gelatin Initiated by Copper) polymer gel dosimeters have been characterized. The variations of speed of sound, ultrasonic attenuation coefficient and density of MAGIC gel with radiation dose and temperature have been quantified. This extends work that has
APA, Harvard, Vancouver, ISO, and other styles
6

Resende, Thiago Dias. "Um estudo para otimização da formulação do dosímetro gel MAGIC-f e avaliação da sua reutilização." Universidade de São Paulo, 2017. http://www.teses.usp.br/teses/disponiveis/59/59135/tde-07072017-123749/.

Full text
Abstract:
A radioterapia é um procedimento que utiliza radiação ionizante de alta energia direcionado ao tumor, para destruir suas células. O objetivo é provocar o maior dano nas células tumorais enquanto se poupa o tecido sadio ao redor, para maximizar este resultado. Devido a alta complexidade dos feixes usados nestes tratamentos, um dosímetro tridimensional é desejado para garantir que a dose esteja sendo entregue da forma como foi planejada, sendo a dosimetria gel polimérica com leitura da dose em Imagens de Ressonância Magnética Nuclear (IRMN), uma opção para esta medida. Esse trabalho utiliza o do
APA, Harvard, Vancouver, ISO, and other styles
7

Pastorello, Bruno Fraccini. "Montagem e caracterização de um fantoma para utilização em radioterapia utilizando imagens convencionais por ressonância magnética e contraste por transferência de magnetização." Universidade de São Paulo, 2006. http://www.teses.usp.br/teses/disponiveis/59/59135/tde-11092007-160124/.

Full text
Abstract:
A dosimetria 3D utilizando gel à base de monômeros é uma importante ferramenta utilizada em casos de Radioterapia, em que há necessidade de uma alta resolução da distribuição espacial de dose. Neste trabalho, desenvolvemos um gel à base de monômeros do acido metacrilico, denominado MAGIC®, com a finalidade de avaliar a distribuição espacial de dose em simulações de tratamento de radioterapia, utilizando duas técnicas de imagens por ressonância magnética, Magnetic Resonance Imaging (MRI): a relaxometria (RT) e a transferência de magnetização (Magnetization Transfer, MT). Para tal, o trabalho fo
APA, Harvard, Vancouver, ISO, and other styles
8

Mangueira, Thyago Fressatti. "Avaliação dosimétrica da solução fricke gel usando a técnica de espectrofotometria para aplicação na dosimetria de elétrons e nêutrons." Universidade de São Paulo, 2009. http://www.teses.usp.br/teses/disponiveis/85/85131/tde-29032012-144938/.

Full text
Abstract:
Neste trabalho as principais características dosímetricas da solução Fricke Xilenol Gel (FXG) foram estabelecidas para futura aplicação clínica na dosimetria de elétrons. As curvas de dose resposta para feixes de nêutrons térmicos para pesquisa em Terapia por Captura de Nêutrons (BNCT) e feixes elétrons de aplicação industrial também foram determinadas. A técnica padrão de leitura utilizada foi espectrofotometria. Para o feixe clínico as reprodutibilidades intra e inter-lotes da solução FXG são melhores que 1,4 % e 5,1 % respectivamente, o comportamento da resposta para o intervalo de dose ent
APA, Harvard, Vancouver, ISO, and other styles
9

Zaias, Herofen. "Desenvolvimento de um novo gel e otimização de leitor para dosimetria química." Universidade de São Paulo, 2006. http://www.teses.usp.br/teses/disponiveis/59/59135/tde-30092010-110923/.

Full text
Abstract:
O interesse científico em se conhecer os efeitos provocados pelo uso da radiação ionizante nos sistemas biológicos, fez com que a área da dosimetria merecesse uma atenção especial na busca de sensores que pudessem traduzir respostas equivalentes às dos tecidos humanos. O presente trabalho mostra a caracterização preliminar e a aplicação de um novo dosímetro químico (FXGA), derivado do FXG, que se diferencia do anterior pela substituição da gelatina de pele de porco \"300 Bloom\" por uma nacional. As leituras de dose absorvida por esse dosímetro são baseadas na absorção ótica e para tal foi des
APA, Harvard, Vancouver, ISO, and other styles
10

Silveira, Michely Cristina da. "Distribuição da dose absorvida no tratamento da micose fungóide através da dosimetria Fricke Xilenol Gel." Universidade de São Paulo, 2010. http://www.teses.usp.br/teses/disponiveis/59/59135/tde-04032011-155301/.

Full text
Abstract:
A radioterapia utiliza a radiação ionizante para a destruição de células tumorais. O controle da dose absorvida de um tipo específico de radiação aplicada a um volume alvo (tumor) é feito através da dosimetria, (uso de sensores de radiação), que neste trabalho foram utilizados os dosímetros químicos Fricke e filme. Dentre os diversos tipos de câncer, indicados para tratamento, utilizando a radiação ionizante, têm-se também a neoplasia Micose Fungóide (MF), linfoma que se alastra na superfície e em profundidade na pele para o qual elétrons com alta energia são utilizados para seu tratamento, de
APA, Harvard, Vancouver, ISO, and other styles
11

Camargo, Shiva do Valle. "Confecção e caracterização de dosímetros luminescentes de cerâmicas de BaTiO3 nanoestruturadas." Universidade de São Paulo, 2013. http://www.teses.usp.br/teses/disponiveis/3/3140/tde-11072014-093623/.

Full text
Abstract:
Conforme pesquisas realizadas na literatura, o estudo do Titanato de Bário (BTO) na dosimetria é inédito, este material foi escolhido porque exibe propriedades luminescentes, demonstradas em experimentos de medidas de espectros de emissão. Para a confecção do BTO fez-se o uso da técnica química Sol-Gel, foi produzido amostras de BTO Puro, BTO dopado e co-dopado com diversas terras-raras. Todas as amostras produzidas sofreram calcinações com temperaturas definidas em 800, 1000 e 1200°C. As dopagens foram realizadas com os seguintes elementos terras-raras: Nd, Tb, Eu, Yb, Er, Pr, e as amostras c
APA, Harvard, Vancouver, ISO, and other styles
12

Rojas, Diana Maritza Cuevas. "Dosimetria 3D de um tratamento simulado de próstata na presença de próteses femorais metálicas." Universidade de São Paulo, 2017. http://www.teses.usp.br/teses/disponiveis/59/59135/tde-11072017-094424/.

Full text
Abstract:
Historicamente a radioterapia é divida em radioterapia externa, braquiterapia e radioisotopoterapia sistemática. As diferenças entre as três está no posicionamento da fonte de radiação com respeito ao corpo humano. Na radioterapia externa a fonte fica a uma certa distância do paciente, já no caso da braquiterapia as fontes podem ser inseridas dentro de cavidades do corpo ou implantadas diretamente nos tecidos. Na radioisotopoterapia sistemática isótopos radiativos são administrados por via oral ou venosa. Dessas três a radioterapia externa é a mais usada pois, ela permite realizar planejamento
APA, Harvard, Vancouver, ISO, and other styles
13

Jayasekera, Piyakeerthi Mangala. "Practical aspects of radiotherapy gel dosimetry." Thesis, Queensland University of Technology, 2000.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
14

Jardine, Paul. "Applications of gel based chemistry dosimetry." Thesis, Queensland University of Technology, 1994. https://eprints.qut.edu.au/37183/1/37183_Jardine_1994.pdf.

Full text
Abstract:
The transformation of Fe2+ to Fe3+ ions in ferrous sulphate-agarose-xylenol orange (FAX) gel due to irradiation results in a change of absorbance in the FAX gel, which can then be used for the dosimetry of the x-ray beam. The project's aim was to investigate the performance of a laser based system that determines the dose distribution of an x-ray field by measuring the change in absorbance of the FAX gel due to irradiation. Initially a one-dimensional laser scanning system was constructed to perform calibration tests on the FAX gel. Calibration curves were obtained at different x-ray energie
APA, Harvard, Vancouver, ISO, and other styles
15

Smith, Shaun T. "Development of gel dosimetry for radiotherapy." Thesis, Queensland University of Technology, 2017. https://eprints.qut.edu.au/102759/1/Shaun_Smith_Thesis.pdf.

Full text
Abstract:
Gel dosimeters have the potential to track radiation beams, improving safety and treatment effectiveness for radiotherapy patients, however despite extensive research over the last three decades, gel dosimeters have yet to achieve widespread clinical acceptance. In this research, a new version of the ‘Fricke’ gel dosimeter was developed which is more clinically viable. The method performs chemical manipulations on the gel ingredients to eliminate the blurring effect of dose information, which is their primary drawback.
APA, Harvard, Vancouver, ISO, and other styles
16

Oliveira, David Marçal Machado de. "Verificação do uso do dosímetro Fricke benzóico xilenol gel em tomografia computadorizada." Universidade de São Paulo, 2011. http://www.teses.usp.br/teses/disponiveis/59/59135/tde-08122011-154718/.

Full text
Abstract:
A tomografia computadorizada (CT) representa a maior fonte de exposição aos raios X médicos e seu uso continua crescendo rapidamente, devido aos aparelhos de última geração com alta resolução de contraste. Uma avaliação dos parâmetros que influenciam a dose absorvida na tomografia asseguram o controle de qualidade e aceitação do equipamento. Os protocolos de CT utilizam câmara de ionização e filme radiográfico para esta avaliação e pela primeira vez, neste trabalho, o dosímetro químico Fricke Benzóico Xilenol Gel (FBXG) foi utilizado. Este dosímetro ao ser irradiado, produz um complexo colorid
APA, Harvard, Vancouver, ISO, and other styles
17

Pires, Elcio Liberato. "Síntese e caracterização de elemento sensor de matriz KAISi3O8, dopadas com Mn ou Gd, obtidos pela técnica sol-gel, visando a aplicação em dosimetria das radiações ionizantes por termoluminescência e luminescência opticamente estimulada." Universidade de São Paulo, 2010. http://www.teses.usp.br/teses/disponiveis/3/3140/tde-19012011-104913/.

Full text
Abstract:
Neste trabalho, estudou-se as propriedades termoluminescentes e fotoluminescentes (em processo anti-Stokes), além de algumas propriedades químicas e físicas, de amostras sintéticas de KAlSi3O8, dopadas com Mn ou Gd, obtidas por meio da técnica sol-gel. O objetivo principal do estudo foi a obtenção de um novo material, com possibilidades reais de aplicação em dosimetria das radiações ionizantes, como elemento sensor de dosímetros luminescentes. As amostras foram obtidas e trabalhadas na forma de pós com tamanho médio de partícula em 600 nm e suas estruturas composta por uma matriz amorfa e com
APA, Harvard, Vancouver, ISO, and other styles
18

Wong, Christopher James, and chrisjwong@yahoo com au. "High Resolution Polymer Gel Dosimetry for Small and Micro Field Dosimetry, and Development of Innovative Polymer Gel Dosimeters." RMIT University. Medical Sciences, 2009. http://adt.lib.rmit.edu.au/adt/public/adt-VIT20091002.161512.

Full text
Abstract:
Current radiotherapy techniques are focused on delivering effective treatments while sparing surrounding healthy tissues. As a result, radiotherapy treatments are using narrower and more tightly conforming therapy techniques. For these treatments to be effective an accurate measure of the dose delivered by these very narrow radiotherapy beams, both in and around the target volume, is required. It is a challenging task for the conventional type dosimeters to determine dose distribution in such small fields. The best example of such fields is microbeam beam radiotherapy (MRT), a developing treat
APA, Harvard, Vancouver, ISO, and other styles
19

Neto, Euclydes Borguezan. "Gel Turnbull Blue aplicado à dosimetria de radiação ultravioleta e visível." Universidade de São Paulo, 2016. http://www.teses.usp.br/teses/disponiveis/59/59135/tde-22122016-135858/.

Full text
Abstract:
O gel radiocrômico Turnbull Blue (TBG) é sensível a raios gamma e x. Este composto tem sido utilizado em dosimetria de radiações ionizantes devido à sua capacidade de simular tecido biológico quando exposto à radiação de alta energia. Após sua irradiação, o TBG sofre uma mudança de cor: o aspecto amarelo torna-se azul devido à formação do corante Turnbull Blue. Essa alteração de cor produz uma larga banda de absorção na faixa espectral do visível, com pico localizado em 690 nm. A intensidade desta banda é proporcional à dose de radiação absorvida. Entretanto, o comportamento do TBG, quando exp
APA, Harvard, Vancouver, ISO, and other styles
20

Schwarcke, Marcelo Menna Barreto. "Caracterização do gel polimérico MAGIC-f para aplicação em medicina nuclear utilizando imagens de ressonância magnética." Universidade de São Paulo, 2013. http://www.teses.usp.br/teses/disponiveis/59/59135/tde-12112013-084219/.

Full text
Abstract:
Este trabalho visa aprimorar e tornar mais precisa a utilização do dosímetro gel polimérico MAGIC-f no estudo da distribuição de dose para fonte radioativas utilizadas na terapia e diagnóstico em medicina nuclear. Para isso foram avaliados os parâmetros de leitura do gel em equipamentos de ressonância magnética e sua resposta quando comparado a resultados obtidos através da utilização do código PENELOPE de simulação Monte Carlo. Dentre as incertezas observadas no processo global da utilização do gel MAGIC-f, sua manufatura foi a que demonstrou uma maior preocupação uma vez que erro na frações
APA, Harvard, Vancouver, ISO, and other styles
21

Sánchez, Mirko Salomón Alva. "Verificação 3D da distribuição da dose em radiocirurgia estereotáxica através de simulação Monte Carlo e dosimetria por ressonância magnética nuclear." Universidade de São Paulo, 2012. http://www.teses.usp.br/teses/disponiveis/59/59135/tde-15052013-193530/.

Full text
Abstract:
A radiocirugia estereotáxica é uma técnica que fornece altas doses de radiação utilizando campos pequenos para conformação da dose no volume alvo do tratamento. Devido à complexidade desta técnica torna-se necessária a verificação da distribuição de dose no volume de tratamento. Neste trabalho, as distribuições tridimensionais (3D) de doses de casos clínicos de neoplasias cranianas foram estudadas utilizando-se um objeto simulador de cabeça. A reconstrução das distribuições de doses nos volumes alvo e nas regiões adjacentes a estes foram avaliadas com o código de simulação PENELOPE, o dosímetr
APA, Harvard, Vancouver, ISO, and other styles
22

Bäck, Sven Å J. "Implementation of MRI gel dosimetry in radiation therapy." Malmö : Lund : Malmö University Hospital ; Lund University, 1998. http://catalog.hathitrust.org/api/volumes/oclc/68945079.html.

Full text
APA, Harvard, Vancouver, ISO, and other styles
23

Ermeneux, Louis. "Dosimétrie des systèmes IRM-LINAC utilisés en radiothérapie externe : caractérisation des faisceaux et évaluation des distributions de dose." Electronic Thesis or Diss., université Paris-Saclay, 2024. http://www.theses.fr/2024UPASP005.

Full text
Abstract:
L'IRM-LINAC est un appareil de radiothérapie guidée par l'imagerie combinant un accélérateur linéaire (LINAC) et un imageur par résonance magnétique (IRM), permettant un meilleur suivi de la tumeur. Des problématiques dosimétriques, associées à la présence du champ magnétique statique, ont été soulevées dans la littérature. L'objectif de la thèse est de développer des outils dosimétriques et des protocoles robustes utilisables sur les IRM-LINAC afin d'améliorer la connaissance des doses délivrées aux patients traités avec ces appareils. La première partie du travail se concentre sur la détermi
APA, Harvard, Vancouver, ISO, and other styles
24

Hepworth, Stephen J. "Investigations into polymer gel dosimetry using magnetic resonance imaging." Thesis, University of Surrey, 2000. http://epubs.surrey.ac.uk/978/.

Full text
APA, Harvard, Vancouver, ISO, and other styles
25

Alrushoud, Abdullah A. "Polymer gel dosimetry in radiation therapy using computed tomography." Thesis, University of Surrey, 2014. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.616921.

Full text
Abstract:
There have been developments in radiation therapy treatment techiques, which lead to an increase in the complexity of these treatments. The aim is to deliver highly conformal three-dimensional (3D) dose distributions, such as stereotactic radiosurgery (SRS). Polymer gel dosimetry offers three-dimensional (3D) dosimetry techniques for dose verification of dose distributions. Nisopropyl- acrylamide (NIP AM) polymer gel was the latest to develop and can be prepared under a normal atmospheric environment and has lower toxicity compared with the highly toxic polymer gels used earlier. NIPAM polymer
APA, Harvard, Vancouver, ISO, and other styles
26

Silva, Ana Luiza Quevedo Ramos da. "Avaliação de parâmetros dosimétricos de fontes de braquiterapia utilizando simulação Monte Carlo e dosimetria gel polimérica." Universidade de São Paulo, 2014. http://www.teses.usp.br/teses/disponiveis/59/59135/tde-06102014-084506/.

Full text
Abstract:
A dosimetria em braquiterapia é importante para garantir a igualdade entre a dose entregue ao paciente e a dose planejada, porém a determinação experimental da dose é difícil devido ao alto gradiente de dose em regiões próximas à fonte. Nesse sentido, a dosimetria gel polimérica têm sido estudada como forma de se obter a distribuição tridimensional das doses dessas fontes. O protocolo da Associação Americana de Físicos em Medicina, intitulado TG-43, propõe um formalismo para o cálculo de dose de fontes de braquiterapia através de parâmetros da atividade, anisotropia e geometria da fonte, além
APA, Harvard, Vancouver, ISO, and other styles
27

Lizar, Jéssica Caroline. "Comparação dosimétrica 3D de tratamentos de câncer de mama com técnica conformacional 3D usando filtros e com IMRT direto e inverso na presença do movimento respiratório." Universidade de São Paulo, 2017. http://www.teses.usp.br/teses/disponiveis/59/59135/tde-30082017-152201/.

Full text
Abstract:
A radioterapia externa pós-operatória em mulheres diagnosticadas com câncer de mama em estágio inicial é tido como um procedimento padrão, no entanto durante o planejamento para irradiação do volume alvo as possíveis incertezas dosimétricas introduzidas dado o movimento respiratório intrínseco da paciente são desconsideradas. Este estudo avalia não apenas a influência da respiração na distribuição tridimensional da dose, mas como essa distribuição se modifica dado a técnica radioterápica empregada para o tratamento. Três técnicas de planejamento foram analisadas: a radioterapia conformacional
APA, Harvard, Vancouver, ISO, and other styles
28

Khoei, Shadi. "Quantitative ultrasound computed tomography imaging of PAGAT radiation dosimetry gel." Thesis, Queensland University of Technology, 2013. https://eprints.qut.edu.au/63958/1/Shadi_Khoei_Thesis.pdf.

Full text
Abstract:
This research developed and scientifically validated a new ultrasound transmission computed tomography system with the aim of quantitative assessment of a polymer gel dosimeter including dose response verification of ultrasonic parameters of attenuation, velocity and broadband ultrasound attenuation (BUA). This work was the first to investigate and report ultrasound frequency dependent attenuation in a gel dosimeter, demonstrating a dose dependence.
APA, Harvard, Vancouver, ISO, and other styles
29

Farajollahi, Ali Reza. "An investigation into the applications of polymer gel dosimetry in radiotherapy." Thesis, Online version, 1998. http://ethos.bl.uk/OrderDetails.do?did=1&uin=uk.bl.ethos.284699.

Full text
APA, Harvard, Vancouver, ISO, and other styles
30

Hurley, Christopher Anthony. "The development of normoxic polymer gel dosimetry using high resolution MRI." Thesis, Queensland University of Technology, 2006. https://eprints.qut.edu.au/16442/1/Christopher_Hurley_Thesis.pdf.

Full text
Abstract:
Dosimetry is a vital component of treatment planning in radiation therapy. Methods of radiation dosimetry currently include the use of: ionization chambers, thermoluminescent dosimeters (TLDs), solid-state detectors and radiographic film. However, these methods are inherently either 1D or 2D and their use involves the perturbation of the radiation beam. Although the dose distribution within tissues following radiation therapy treatments can be modeled using computerized treatment planning systems, a need exists for a dosimeter that can accurately measure dose distributions directly and prod
APA, Harvard, Vancouver, ISO, and other styles
31

Hurley, Christopher Anthony. "The development of normoxic polymer gel dosimetry using high resolution MRI." Queensland University of Technology, 2006. http://eprints.qut.edu.au/16442/.

Full text
Abstract:
Dosimetry is a vital component of treatment planning in radiation therapy. Methods of radiation dosimetry currently include the use of: ionization chambers, thermoluminescent dosimeters (TLDs), solid-state detectors and radiographic film. However, these methods are inherently either 1D or 2D and their use involves the perturbation of the radiation beam. Although the dose distribution within tissues following radiation therapy treatments can be modeled using computerized treatment planning systems, a need exists for a dosimeter that can accurately measure dose distributions directly and prod
APA, Harvard, Vancouver, ISO, and other styles
32

Valente, M. A. "Fricke gel dosimetry for 3D imaging of absorbed dose in radiotherapy." Doctoral thesis, Università degli Studi di Milano, 2007. http://hdl.handle.net/2434/41638.

Full text
Abstract:
The overall aim of this thesis was to develop improvements for 3D dosimetry system, based on Fricke solution, in order to achieve accurate 3D absorbed dose distributions by means of visible light transmittance analysis. Such a system would represent a useful tool for 3D treatment planning verification. In particular, the main objectives were: To make a Fricke gel dosimeter selecting proper gelling substance and optimizing gel quantity according to the dosimeter response. To develop a Fricke gel dosimeter preparation protocol in order to establish an optimal elaboration process. To evaluate
APA, Harvard, Vancouver, ISO, and other styles
33

Silveira, Matheus Antônio da. "Dosimetria gel no controle de qualidade tridimensional para radioterapia de intensidade modulada (IMRT) de próstata." Universidade de São Paulo, 2014. http://www.teses.usp.br/teses/disponiveis/59/59135/tde-03072014-233935/.

Full text
Abstract:
A radioterapia de intensidade modulada (IMRT) é uma das mais modernas técnicas radioterapêuticas que permite a entrega de elevadas e complexas distribuição de doses ao volume tumoral, que necessita de novos métodos para o controle de qualidade dos procedimentos efetuados. Nos serviços de radioterapia costuma-se usar para o controle de qualidade do sistema de planejamento, a câmara de ionização para verificação pontual da dose e um dispositivo com diodos semicondutores (MapCHECK2) para a verificação bidimensional em um plano da fluência planejada, entretanto, para a verificação tridimensional d
APA, Harvard, Vancouver, ISO, and other styles
34

Pianoschi, Thatiane Alves. "Estudo de dosimetria gel polimérica em radioterapia com feixes de elétrons utilizando ressonância magnética e simulação Monte Carlo." Universidade de São Paulo, 2014. http://www.teses.usp.br/teses/disponiveis/59/59135/tde-07102014-113550/.

Full text
Abstract:
Radioterapia com feixe de elétrons tem sido empregada, frequentemente, para tratamentos de neoplasias superficiais, devido às características de alcance bem definido e alto gradiente de dose em pouca profundidade. Para que as novas técnicas radioterápicas com esse tipo de feixe possam ser implementadas com segurança é necessária a realização de um controle da qualidade rigoroso. Protocolos recomendam que o controle da qualidade para esse tipo de feixe seja realizado com câmara de ionização, porém dosímetros termoluminescentes, diodos e filmes também são empregados com essa finalidade. Entreta
APA, Harvard, Vancouver, ISO, and other styles
35

Dias, Juliana Rosada. "Caracterização dosimétrica de gel tipo VIPARnd através de técnicas ópticas para feixes de raios x de 6mv usados em radioterapia externa." reponame:Repositório Institucional da UnB, 2015. http://repositorio.unb.br/handle/10482/19010.

Full text
Abstract:
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2015.<br>Submitted by Guimaraes Jacqueline (jacqueline.guimaraes@bce.unb.br) on 2015-11-20T09:38:06Z No. of bitstreams: 1 2015_JulianaRosadaDias.pdf: 31393679 bytes, checksum: c8721c906510421d6c5a443a36752c94 (MD5)<br>Approved for entry into archive by Patrícia Nunes da Silva(patricia@bce.unb.br) on 2015-12-21T11:38:43Z (GMT) No. of bitstreams: 1 2015_JulianaRosadaDias.pdf: 31393679 bytes, checksum: c8721c906510421d6c5a443a36752c94 (MD5)<br>Made available in DSpace on 2015-12-21T11:38
APA, Harvard, Vancouver, ISO, and other styles
36

Moreira, Marcos Vasques. "Dosimetria Fricke Xilenol Gel na região de não-equilíbrio para radioterapia com feixes de fótons e elétrons." Universidade de São Paulo, 2012. http://www.teses.usp.br/teses/disponiveis/59/59135/tde-22072013-102348/.

Full text
Abstract:
Quando se utiliza feixes de radiação ionizante de fótons e elétrons com altas energias, a região mais perto da superfície do paciente, região de não-equilíbrio, pode ter o comportamento das doses absorvidas comprometido devido a vários fatores como a presença de materiais auxiliares na radioterapia, exemplo o \"bolus\" (para superficializar a dose absorvida) e materiais imobilizadores como a máscara termoplástica. Dependendo da significância da incerteza no valor da dose absorvida, medidas devem ser tomadas para que esta seja mais próxima possível daquela prescrita. O objetivo desse trabalho é
APA, Harvard, Vancouver, ISO, and other styles
37

Baldock, Clive. "Aspects of dosimetry using radiation sensitive gels." Thesis, King's College London (University of London), 2001. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.249297.

Full text
APA, Harvard, Vancouver, ISO, and other styles
38

Afonso, Luciana Caminha. "Estudo da influência de partículas de ouro na dose absorvida em tecido mole utilizando dosimetria com gel polimérico." Universidade de São Paulo, 2011. http://www.teses.usp.br/teses/disponiveis/85/85131/tde-21112011-091727/.

Full text
Abstract:
A presença de material de alto número atômico adjacente ao tecido mole aumenta localmente a dose absorvida pelo tecido quando submetido à radiação. Este efeito ocorre devido aos fotoelétrons ejetados do material de alto número atômico. Dosímetros de gel polimérico com partículas de ouro foram utilizados para investigar este efeito. Foram realizados cálculos analíticos para estimar o aumento de dose e simulações com o método de Monte Carlo. A irradiação de amostras de gel polimérico (GP) puro e com 0,005 gAu/gGP utilizando um feixe de raios X produzido por um potencial de 150 kV filtrado com 4
APA, Harvard, Vancouver, ISO, and other styles
39

Asena, Andre. "Dosimetry in the vicinity of high-density materials in radiotherapy." Thesis, Queensland University of Technology, 2017. https://eprints.qut.edu.au/103983/1/Andre_Asena_Thesis.pdf.

Full text
Abstract:
The success of radiation therapy treatments is largely dependent on the ability to accurately deliver the prescribed dose to a patient within a narrow tolerance. However, the human body consists of many components, which vary in density and can cause treatment complications. In this research, a methodology is established whereby the effects of high-density medical implants on radiotherapy treatments can be quantified accurately and efficiently. A better understanding of the impact of these medical implants on radiotherapy dose distributions means more accurate treatments can be delivered with
APA, Harvard, Vancouver, ISO, and other styles
40

Amin, Md Nurul. "Polymer gel dosimetry applied to β particles, electrons and 300 kV X-rays". Thesis, University of Leicester, 2003. http://hdl.handle.net/2381/29451.

Full text
Abstract:
Polymer gels were used with magnetic resonance imaging (MRI) to measure three-dimensional absorbed dose distributions for beta particles, electron and x-rays beams that are used in radiotherapy. The manufacturing processes and calibration procedures for two dosimeters (hypoxic PAG and normoxic MAGIC gels) were investigated. The response of both gels was energy independent over a range of electron and photon energies commonly used for radiotherapy. However, dose response of both gels was dependent on the temperature at the time of MR scanning, while MAGIC was also dependent on the temperature a
APA, Harvard, Vancouver, ISO, and other styles
41

Gear, Jonathan. "Polymer gels for dosimetry in targeted radionuclide therapy." Thesis, Institute of Cancer Research (University Of London), 2009. http://publications.icr.ac.uk/10124/.

Full text
Abstract:
This thesis Presents an investigation into the use of polymer gel dosimeters for analysis in targeted radionuclide therapy (TRT). The project aims to establish viability, technical issues, and potential uses of polymer gel dosimetry when incorporating radioisotopes. The thesis begins by outlining the current status of TRT and the need for accurate dosimetry. The inaccuracies of the dosimetry methods being employed are highlighted, as is the requirement of a "gold standard" method for dosimetry quality assurance. Polymer gel dosimeters are porposed as a possible means of achieving this. As a re
APA, Harvard, Vancouver, ISO, and other styles
42

Aranda, Lara Liliana, and García Eugenio Torres. "Modelado de Tejido Biológico con Maniquí de Gel de AGAR por dosimetría del 99mTc." Tesis de Licenciatura, Medicina-Quimica, 2013. http://hdl.handle.net/20.500.11799/14420.

Full text
APA, Harvard, Vancouver, ISO, and other styles
43

Lima, Hestia Raissa Batista Reis. "Síntese e caracterização do LiAlSi2O6 por novas rotas de produção." Universidade Federal de Sergipe, 2013. https://ri.ufs.br/handle/riufs/5311.

Full text
Abstract:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior<br>The spodumene (LiAlSi2O6 - LAS) is a silicate that has shown good results for high-dose dosimetry for gamma rays. This silicate may be obtained naturally or synthetically. The synthetic spodumene has been produced by solid state reaction, whose difficulty arises from the need to employ high temperatures. This paper aims to produce LAS through two different production routes: the proteic sol-gel and Pechini methods. The material produced was characterized by X-ray diffraction (XRD), differential thermal analysis (DTA) and thermograv
APA, Harvard, Vancouver, ISO, and other styles
44

Acurio, Erick Sebastian Rundo. "Dosimetria gel no controle de qualidade tridimensional em tratamento de radioterapia com intensidade modulada e técnica SMART (Simultaneous Modulated Accelerated Radiation Therapy)." Universidade de São Paulo, 2016. http://www.teses.usp.br/teses/disponiveis/59/59135/tde-11072017-093423/.

Full text
Abstract:
A radioterapia com intensidade modulada de feixe (IMRT) possibilitou a realização de tratamentos de múltiplos alvos simultaneamente em um esquema de tratamento acelerado conhecido como SMART (Simultaneous Modulated Accelerated Radiation Therapy). Estes tratamentos requerem um rigoroso controle de qualidade (QA) que deveria ser realizado, idealmente, em três dimensões. Uma potencial ferramenta para dosimetria tridimensional (3D) é o uso de gel polimérico associado à leitura de doses com Imagens de Ressonância Magnética Nuclear (IRMN). Neste trabalho, a dosimetria 3D com o gel MAGIC-f foi aplica
APA, Harvard, Vancouver, ISO, and other styles
45

Capeleti, Felipe Favaro. "Dosimetria em tomografia computadorizada e avaliação do perfil de dose empregando dosímetro Fricke gel e a técnica de imageamento por ressonância magnética." Universidade de São Paulo, 2014. http://www.teses.usp.br/teses/disponiveis/85/85131/tde-15102014-105653/.

Full text
Abstract:
Neste trabalho foi desenvolvido um novo método para a determinação das doses absorvidas nos exames de tomografia computadorizada, utilizando a dosimetria com Fricke gel desenvolvido no IPEN. Foram determinadas as doses absorvidas por diferentes metodologias de análise, como a espectrometria de absorção óptica, câmaras de ionização e imageamento por ressonância magnética. Foram realizados testes de limite mínimo de sensibilidade da solução de Fricke gel, repetitividade de sinal da solução de Fricke gel e dos equipamentos de tomografia computadorizada, sensibilidade de detecção, entre outros. F
APA, Harvard, Vancouver, ISO, and other styles
46

Trapp, Jamie Vincent. "Imaging and radiation interactions of polymer gel dosimeters." Thesis, Queensland University of Technology, 2003. https://eprints.qut.edu.au/15904/1/Jamie_Trapp_Thesis.pdf.

Full text
Abstract:
Aim: The past two decades have seen a large body of work dedicated to the development of a three dimensional gel dosimetry system for the recording of radiation dose distributions in radiation therapy. The purpose of much of the work to date has been to improve methods by which the absorbed dose information is extracted. Current techniques include magnetic resonance imaging (MRI), optical tomography, Raman spectroscopy, x-ray computed tomography (CT) and ultrasound. This work examines CT imaging as a method of evaluating polymer gel dosimeters. Apart from publications resulting from this
APA, Harvard, Vancouver, ISO, and other styles
47

Trapp, Jamie Vincent. "Imaging And Radiation Interactions Of Polymer Gel Dosimeters." Queensland University of Technology, 2003. http://eprints.qut.edu.au/15904/.

Full text
Abstract:
Aim: The past two decades have seen a large body of work dedicated to the development of a three dimensional gel dosimetry system for the recording of radiation dose distributions in radiation therapy. The purpose of much of the work to date has been to improve methods by which the absorbed dose information is extracted. Current techniques include magnetic resonance imaging (MRI), optical tomography, Raman spectroscopy, x-ray computed tomography (CT) and ultrasound. This work examines CT imaging as a method of evaluating polymer gel dosimeters. Apart from publications resulting from this w
APA, Harvard, Vancouver, ISO, and other styles
48

Lama, Lucas Sacchini Del. "Caracterização e adaptação do dosímetro Fricke para dosimetria em irradiação de sangue." Universidade de São Paulo, 2013. http://www.teses.usp.br/teses/disponiveis/59/59135/tde-11112013-115906/.

Full text
Abstract:
A Doença Enxerto Contra Hospedeiro Associada à Transfusão (DECH-AT) é uma reação transfusional rara, porém fatal, que ocorre devido à presença de células T no sangue doado e que pode ser prevenida por meio da irradiação do sangue do doador e de seus componentes antes da transfusão. Assim, o controle de qualidade associado à irradiação do sangue é necessário para se garantir a qualidade do produto transfundido. Neste trabalho é proposta a caracterização e a adaptação da resposta do dosímetro Fricke para uso na dosimetria da irradiação de sangue, mais especificamente o Fricke Xilenol Gel (FXG).
APA, Harvard, Vancouver, ISO, and other styles
49

AFONSO, LUCIANA C. "Estudo da influência de partículas de ouro na dose absorvida em tecido mole utilizando dosimetria com gel polimérico." reponame:Repositório Institucional do IPEN, 2011. http://repositorio.ipen.br:8080/xmlui/handle/123456789/10034.

Full text
Abstract:
Made available in DSpace on 2014-10-09T12:34:01Z (GMT). No. of bitstreams: 0<br>Made available in DSpace on 2014-10-09T13:59:40Z (GMT). No. of bitstreams: 0<br>Tese (Doutoramento)<br>IPEN/T<br>Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
APA, Harvard, Vancouver, ISO, and other styles
50

Cavinato, Christianne Cobello. "Padronização do método de dosimetria Fricke gel e avaliação tridimensional de dose empregando a técnica de imageamento por ressonância magnética." Universidade de São Paulo, 2009. http://www.teses.usp.br/teses/disponiveis/85/85131/tde-05112009-102509/.

Full text
Abstract:
Neste trabalho foi padronizado o método de obtenção da solução Fricke gel desenvolvida no IPEN. Foram comparados os resultados obtidos para diferentes qualidades do gel utilizado na preparação das soluções e a influência da concentração de gelatina na resposta das soluções dosimétricas. Testes de desempenho tais como: resposta em função da dose, limites mínimo e máximo de detecção, reprodutibilidade da resposta, entre outros, foram realizados utilizando diferentes tipos de radiação e empregando as técnicas de espectrofotometria de Absorção Óptica (AO) e Ressonância Magnética (RM). Os intervalo
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!