Contents
Academic literature on the topic 'Dosimétrie personnalisée'
Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles
Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Dosimétrie personnalisée.'
Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.
You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.
Journal articles on the topic "Dosimétrie personnalisée"
Moignier, A., S. Derreumaux, D. Broggio, M. Chea, G. Boisserie, J. F. Paul, T. Girinsky, D. Franck, B. Aubert, and J. J. Mazeron. "Dosimétrie cardiovasculaire personnalisée à l’aide de fantômes numériques hybrides en radiothérapie." Cancer/Radiothérapie 16, no. 5-6 (September 2012): 523. http://dx.doi.org/10.1016/j.canrad.2012.07.024.
Full textDieudonné, A., I. Gardin, M. Ben Reguiga, S. Sebahoun, S. Legendre, D. Le Guludec, and R. Lebtahi. "Dosimétrie personnalisée en radiothérapie interne vectorisée : exemple du traitement des carcinomes hépatocellulaires par microsphères marquées à l’yttrium 90." Médecine Nucléaire 36, no. 4 (April 2012): 215–21. http://dx.doi.org/10.1016/j.mednuc.2012.02.011.
Full textGarin, E., L. Tselikas, B. Guiu, J. Chaley, S. Laffont, J. Edeline, T. de Baere, et al. "Impact de la dosimétrie personnalisée sur la réponse tumorale des carcinomes hépatocellulaires (CHC) traités par microbilles de verre marquées à l’yttrium 90 : résultats d’une étude multicentrique randomisée." Médecine Nucléaire 43, no. 2 (March 2019): 180. http://dx.doi.org/10.1016/j.mednuc.2019.01.018.
Full textGarin, E., L. Lenoir, Y. Rollan, S. Laffont, N. Icard, J. Edeline, and E. Boucher. "Une approche dosimétrique personnalisée et le concept d’intensification induisent une survie globale prolongée chez les patients avec thromboses portes traités par radioembolisation avec les TheraSphere®." Médecine Nucléaire 38, no. 3 (May 2014): 138. http://dx.doi.org/10.1016/j.mednuc.2014.03.038.
Full textDissertations / Theses on the topic "Dosimétrie personnalisée"
Hadid, Lama. "Optimisation de la radioprotection en médecine nucléaire : de la dosimétrie de référence à la dosimétrie personnalisée." Paris 7, 2011. http://www.theses.fr/2011PA077198.
Full textIn nuclear medicine, radiopharmaceuticals are distributed in the body and thus, each organ can deliver a fraction of emitted energy in tissues. Therefore, dose calculations must be assessed accurately and realistically to ensure the patient radiation protection. Absorbed doses were until now based on mathematical standard models and electron transport approximations. The International Commission on Radiological Protection (ICRP) has recently adopted voxel phantoms as a more realistic representation of the reference adult. The main goal of this thesis was to study the influence of the new reference models and Monte Carlo methods on the major dosimetric quantities. In addition, the contribution of patients' specific geometry to the absorbed dose was compared to a standard geometry. Particular attention was paid to the bone marrow which is characterized by a high radiosensitivity and a complex microscopic structure. An accurate alpha dosimetry was assessed for bone marrow using microscopic images of several trabecular bone sites. The results showed variations in the absorbed fractions as a function of the particles" energy, the skeletal site and the amount of fat within marrow cavities, three parameters which are not taken into account in the values published by the ICRP. Finally, the heterogeneous activity distribution of the radiopharmaceuticals was considered within the framework of the treatment of a hepatocellular carcinoma with selective internai radiotherapy using Yttrium-90 through the analysis of dose-volume histograms. The developments made in this thesis show the importance and the feasibility of performing a personalized dosimetry for nuclear medicine patients
Maigne, Lydia. "Dosimétrie personnalisée par simulation Monte Carlo GATE sur grille de calcul. Application à la curiethérapie oculaire." Phd thesis, Université Blaise Pascal - Clermont-Ferrand II, 2005. http://tel.archives-ouvertes.fr/tel-00011404.
Full textDes points kernels de dose d'électrons mono-énergétiques et poly-énergétiques ont été simulés en utilisant la plate-forme GATE et comparés à d'autres codes Monte Carlo. Trois versions des packages de librairies ont été utilisées pour les comparaisons (5.2, 6.2 et 7.0). Les résultats montrent que l'implémentation de la diffusion multiple est responsable des différences observées entre les codes. Les simulations de traitements de curiethérapie oculaire comparées avec d'autres Monte Carlo et des mesures montrent un bon accord. La transcription des unités Hounsfield, à partir des données scanner sur l'anatomie du patient, en paramètres tissulaires est l'autre étude présentée pour une utilisation prochaine de GATE sur des images voxélisées pour la dosimétrie personnalisée. Les infrastructures des projets DataGrid puis d'EGEE ont été utilisées pour déployer les simulations GATE afin de réduire leur temps de calcul dans le but de les utiliser en routine clinique.
La méthode utilisée pour paralléliser les simulations GATE est la division du générateur de nombres aléatoires (RNG) en séquences indépendantes. Des tests de temps de calcul réalisés sur des bancs tests de grille montrent qu'un gain significatif est obtenu. Les fonctionnalités pour diviser, lancer et contrôler les simulations GATE sur une infrastructure de grille ont été implémentées sur le portail web GENIUS. Un premier prototype de ce portail est accessible à partir d'un centre hospitalier pour l'utilisation de la précision des algorithmes Monte Carlo de manière transparente et sécurisée pour des traitements de cancer de l'œil.
Petitguillaume, Alice. "Dosimétrie Monte Carlo personnalisée pour la planification et l’évaluation des traitements de radiothérapie interne : développement et application à la radiothérapie interne sélective (SIRT)." Thesis, Paris 11, 2014. http://www.theses.fr/2014PA112190/document.
Full textMedical techniques in full expansion arousing high therapeutic expectations, targeted radionuclide therapies (TRT) consist of administering a radiopharmaceutical to selectively treat tumors. Nowadays, the activity injected to the patient is generally standardized. However, in order to establish robust dose-effect relationships and to optimize treatments while sparing healthy tissues at best, a personalized dosimetry must be performed, just like actual clinical practice in external beam radiotherapy. In that context, this PhD main objective was to develop, using the OEDIPE software, a methodology for personalized dosimetry based on direct Monte Carlo calculations. The developed method enables to calculate the tridimensional distribution of absorbed doses depending on the patient anatomy, defined from CT or MRI data, and on the patient-specific activity biodistribution, defined from SPECT or PET data. Radiobiological aspects, such as differences in radiosensitivities and repair time constants between tumoral and healthy tissues, have also been integrated through the linear-quadratic model. This methodology has been applied to the selective internal radiation therapy (SIRT) which consists in the injection of 90Y-microspheres to selectively treat unresectable hepatic cancers. Distributions of absorbed doses and biologically effective doses (BED) along with the equivalent uniform biologically effective doses (EUD) to hepatic lesions have been calculated from 99mTc-MAA activity distributions obtained during the evaluation step for 18 patients treated at hôpital européen Georges Pompidou. Those results have been compared to classical methods used in clinics and the interest of accurate and personalized dosimetry for treatment planning has been investigated. On the one hand, the possibility to increase the activity in a personalized way has been highlighted with the calculation of the maximal activity that could be injected to the patient while meeting tolerance criteria on organs at risk. On the other hand, the use of radiobiological quantities has also enabled to evaluate the potential added value of fractionated protocols in SIRT. The developed tool can thus be used as a help for the optimization of treatment plans. Moreover, a study has been initiated to improve the reconstruction of post-treatment data from 90Y-SPECT. The estimation from those data of doses delivered during treatment could allow to predict tumoral control and to anticipate healthy tissues toxicity as well as to establish precise dose-effect relationships for those treatments
Morschhauser, Franck. "Nouvelles modalités (consolidation, fractionnement) de radioimmunothérapie par 90Y-ibritumomab tiuxetan ("Zevalin") en traitement de première ligne des lymphomes malin non hodgkinien de type folliculaire: efficacité, toxicité et approche dosimétrique personnalisée." Phd thesis, Université du Droit et de la Santé - Lille II, 2008. http://tel.archives-ouvertes.fr/tel-00355344.
Full textObjectifs et méthodes : nous avons successivement évalué 2 nouvelles modalités d'utilisation du Zevalin dans le cadre du traitement de première ligne du LF. Une première approche a consisté à évaluer l'efficacité et la tolérance de Zevalin (15MBq/Kg) en consolidation après obtention d'une réponse au moins partielle au traitement d'induction dans le cadre d'un essai multicentrique international randomisé. Une deuxième approche, cette fois en traitement inaugural du LF, a consisté à évaluer une RIT fractionnée en 2 doses de Zevalin(11.1 MBq/kg chacune) à 9-13 semaines d'intervalle chez des patients avec forte masse tumorale dans un essai de phase 2. Cette deuxième approche a été mise à profit pour établir et tester en multicentrique un protocole d'étude dosimétrique clinique personnalisé avec imagerie quantitative (planaire et tridimensionnelle) et dosimétrie sanguine afin d'analyser la relation dose-effet (efficacité et toxicité) après chacune des 2 fractions de Zevalin. L'acquisition des images a été effectuée sur 3 centres (Lille, Nantes, Manchester) et le traitement des images avec calcul dosimétrique au niveau des organes majeurs, des principales cibles tumorales et de la moelle osseuse a été centralisé.
Conclusion : dans le traitement de première ligne du LF, la consolidation par Zevalin permet l'obtention d'une réponse complète chez 77% des répondeurs partiels après l'induction et améliore la survie sans progression d'au moins 2 ans sans toxicité surajoutée. La RIT fractionnée par Zevalin en traitement inaugural est faisable et le protocole standardisé d'acquisition d'imagerie quantitative applicable en multicentrique. Les résultats préliminaires de dosimétrie obtenus pour 6 patients après imagerie quantitative planaire personnalisée sont présentés.
Morschhauser, Franck. "Nouvelles modalités (consolidation, fractionnement) de radioimmunothérapie par 90 Y-ibritumomab tiuxetan ("Zevalin") en traitement de première ligne des lymphomes malin non hodgkiniens de type folliculaire : efficacité, toxicité et approche dosimétrique personnalisée." Lille 2, 2008. http://tel.archives-ouvertes.fr/tel-00355344/fr/.
Full textChiavassa, Sophie. "Développement d'un outil dosimétrique personnalisé pour la radioprotection en contamination interne et la radiothérapie vectorisée en médecine nucléaire." Toulouse 3, 2005. http://www.theses.fr/2005TOU30182.
Full textCurrent internal dosimetric estimations are based on the MIRD formalism and used standard mathematical models. These standard models are often far from a given patient morphology and do not allow to perform patient-specific dosimetry. The aim of this study was to develop a personalised dosimetric tool, which takes into account real patient morphology, composition and densities. This tool, called OEDIPE, a French acronym of Tool for the Evaluation of Personalised Internal Dose, is a user-friendly graphical interface. OEDIPE allows to create voxel-based patient-specific geometries and associates them with the MCNPX Monte Carlo code. Radionuclide distribution and absorbed dose calculation can be performed at the organ and voxel scale. OEDIPE can be used in nuclear medicine for targeted radiotherapy and in radiation protection in case of internal contamination
Elazhar, Halima. "Dosimétrie neutron en radiothérapie : étude expérimentale et développement d'un outil personnalisé de calcul de dose Monte Carlo." Thesis, Strasbourg, 2018. http://www.theses.fr/2018STRAE013/document.
Full textTreatment optimization in radiotherapy aims at increasing the accuracy of cancer cell irradiation while saving the surrounding healthy organs. However, the peripheral dose deposited in healthy tissues far away from the tumour are currently not calculated by the treatment planning systems even if it can be responsible for radiation induced secondary cancers. Among the different components, neutrons produced through photo-nuclear processes are suffering from an important lack of dosimetric data. An experimental and Monte Carlo simulation study of the secondary neutron production in radiotherapy led us to develop an algorithm using the Monte Carlo calculation precision to estimate the 3D neutron dose delivered to the patient. Such a tool will allow the generation of dosimetric data bases ready to be used for the improvement of “dose-risk” mathematical models specific to the low dose irradiation to peripheral organs occurring in radiotherapy
Germain, François. "L'utilisation de marges personnalisées dans le traitement du cancer du poumon en radiothérapie." Master's thesis, Université Laval, 2005. http://hdl.handle.net/20.500.11794/19429.
Full textIndividualized margins in radiotherapy planning of lung cancer: analysis of physiological movements and their dosimetric impacts OBJECTIVE: This study is an analysis of physiological movements and their dosimetric impacts when a single thoracic CT-scan is used for treatment planning purposes in radiation oncology. METHODS: This is a study of 15 patients. Three-dimensional conformal radiation therapy was (3D-CRT) was used. A reference clinical plan was constructed and compared with plans using individualized margins (obtained by using five CT-scans). Volumetric and dosimetric analyses were made for each. RESULTS: The total volume occupied by GTV progressed quickly with the fusion of CT-scans. For a similar coverage, target volume was smaller and lung irradiation was slightly decreased. CONCLUSIONS: Even if the individualized margin was used, it produced a limited clinical advantage. All techniques that increase total volume with an aim to include more movements should come to similar conclusions.