To see the other types of publications on this topic, follow the link: Dual plating.

Journal articles on the topic 'Dual plating'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 50 journal articles for your research on the topic 'Dual plating.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse journal articles on a wide variety of disciplines and organise your bibliography correctly.

1

Ziegler, Connor G., Zachary S. Aman, Hunter W. Storaci, et al. "Low-Profile Dual Small Plate Fixation Is Biomechanically Similar to Larger Superior or Anteroinferior Single Plate Fixation of Midshaft Clavicle Fractures." American Journal of Sports Medicine 47, no. 11 (2019): 2678–85. http://dx.doi.org/10.1177/0363546519865251.

Full text
Abstract:
Background: Limited biomechanical data exist for dual small plate fixation of midshaft clavicle fractures, and no prior study has concurrently compared dual small plating to larger superior or anteroinferior single plate and screw constructs. Purpose: To biomechanically compare dual small orthogonal plating, superior plating, and anteroinferior plating of midshaft clavicle fractures by use of a cadaveric model. Study Design: Descriptive laboratory study. Methods: The study used 18 cadaveric clavicle specimens (9 pairs total), and 3 plating techniques were studied: anteroinferior, superior, and
APA, Harvard, Vancouver, ISO, and other styles
2

Shah, Arvind, Saurabh Agarwal, and Abhishek Nagaich. "Comparative study of single vs. dual plating in distal femur fracture." Journal of Bone and Joint Diseases 39, no. 1 (2024): 1–8. http://dx.doi.org/10.4103/jbjd.jbjd_27_23.

Full text
Abstract:
Abstract Background: Despite recent advances in techniques and implants, the treatment of intra-articular, multifragmentary distal femoral fractures OTA type C remains a challenge. Fracture shortening with extension and varus deformities of the distal articular surface is typical. During the fixation of such injuries, the surgeon aims to achieve anatomical articular reduction and preserve the blood supply while providing rigid, stable, fixation that is strong enough to withstand early functional mobilization. Objectives: The purpose is to compare and evaluate the functional outcome, subjective
APA, Harvard, Vancouver, ISO, and other styles
3

Lee, Hsin-Hsin, Hao-Chun Chuang, Wei-Chin Lin, et al. "Comparing Single and Dual Plating in Displaced Scapular Body Fractures: A Retrospective Study of Clinical and Functional Outcomes." Journal of Clinical Medicine 14, no. 13 (2025): 4740. https://doi.org/10.3390/jcm14134740.

Full text
Abstract:
Background: Scapular body fractures, when significantly displaced or malunited, can cause glenohumeral discomfort and functional disability. This study compares single- and dual-plating techniques in terms of pain, function, and active range of motion (aROM) in patients with scapular body fractures. Methods: Twenty-eight patients with scapular fractures were retrospectively analyzed, with sixteen undergoing single plating treatment and twelve dual plating treatment. The mean age was 44.9 years, and the mean follow-up was 14 months for single plating and 13.8 months for dual plating. Outcomes i
APA, Harvard, Vancouver, ISO, and other styles
4

Katthagen, J. Christoph, Benedikt Schliemann, Philipp A. Michel, Lukas F. Heilmann, Felix Dyrna, and Michael J. Raschke. "Clinical Application and Outcomes of Upper Extremity Double Plating." Zeitschrift für Orthopädie und Unfallchirurgie 158, no. 02 (2019): 227–37. http://dx.doi.org/10.1055/a-0862-1070.

Full text
Abstract:
AbstractDual plating in fractures of the upper extremity is well established for the distal humerus. The indication for the use of dual plating has been expanded over the last few years. While dual plating was originally frequently used in revisions of non-unions, it is nowadays also used in primary fixation of diverse complex fractures of the upper extremity. The high biomechanical fixation strength of dual plating is advantageous in regions with high bending and torsional stresses, such as the humeral shaft. An additional anterior plate provides high fixation strength and reduces the risk of
APA, Harvard, Vancouver, ISO, and other styles
5

Ward, Thomas Robert William, Kanai Garala, and Bryan Riemer. "Failure of dual plating in a complex open distal femur fracture as the result of major trauma." BMJ Case Reports 14, no. 12 (2021): e245362. http://dx.doi.org/10.1136/bcr-2021-245362.

Full text
Abstract:
A 61-year-old polytrauma patient was admitted with a right distal comminuted metaphyseal femoral fracture with intra-articular extension (Orthopaedic Trauma Association 33C2.3 classification) among other injuries. Due to the high degree of comminution and massive bone loss, this was initially managed with a dual plating open reduction internal fixation. Dual plating has shown to be a superior fixation method than single variable angle locking compression plate (VA-LCP) plating providing greater fixation in metaphyseal bone. Our case reports the failure of dual plating which required removal of
APA, Harvard, Vancouver, ISO, and other styles
6

Zhuang, Yunqiang, Yadi Zhang, Long Zhou, Jun Zhang, Gangqiang Jiang, and Ji Wu. "Management of comminuted mid-shaft clavicular fractures: Comparison between dual-plate fixation treatment and single-plate fixation." Journal of Orthopaedic Surgery 28, no. 2 (2020): 230949902091579. http://dx.doi.org/10.1177/2309499020915797.

Full text
Abstract:
Background: We consider dual-plate fixation to improve construct rigidity in cases with fracture complexity. The purpose of this study is to compare the rate of nonunion, prognosis, and complications at 6–12 months for surgically treated acute mid-shaft clavicle fractures when extra-periosteal dual-plate fixation is used in place of the conventional single-plate fixation. Materials and Methods: The comparative study was conducted on 47 patients who received acute mid-shaft clavicular fracture treatment in our hospital from March 2015 to July 2018. All patients were divided into dual-plate fixa
APA, Harvard, Vancouver, ISO, and other styles
7

Qadir, Abdul, Muhammad Muzzammil, Muhammad Tahir Lakho, and Maratib Ali. "Complicated Tibial Plateau Fractures In Young Patients: Functional Outcome With Dual Plating Via two Incision Technique." Trauma International 5, no. 1 (2019): 28–31. http://dx.doi.org/10.13107/ti.2019.v05i01.081.

Full text
Abstract:
Objective: Motorbike accidents contribute one of the most important factors of tibial plateau fracture among young populations in Karachi Pakistan. Most surgeons feel challenging to treatment complicated bicondylar fractures of the tibial plateau.This prospective study was designed to evaluate the functional outcomes of dual plating through a two-incisions technique for the fixation of complicated bicondylar tibial plateau fractures in young patients in Karachi Pakistan. Methods: This prospective study includes 94 cases of Type V and VI tibial plateau fractures of young patient’s age range fro
APA, Harvard, Vancouver, ISO, and other styles
8

Rollick, Natalie C., Naomi E. Gadinsky, Craig E. Klinger, et al. "The effects of dual plating on the vascularity of the distal femur." Bone & Joint Journal 102-B, no. 4 (2020): 530–38. http://dx.doi.org/10.1302/0301-620x.102b4.bjj-2019-1776.

Full text
Abstract:
Aims Dual plating of distal femoral fractures with medial and lateral implants has been performed to improve construct mechanics and alignment, in cases where isolated lateral plating would be insufficient. This may potentially compromise vascularity, paradoxically impairing healing. This study investigates effects of single versus dual plating on distal femoral vascularity. Methods A total of eight cadaveric lower limb pairs were arbitrarily assigned to either 1) isolated lateral plating, or 2) lateral and medial plating of the distal femur, with four specimens per group. Contralateral limbs
APA, Harvard, Vancouver, ISO, and other styles
9

Xiong, Fangyu, Zhouyang Jiang, Shuangshuang Tan, and Qinyou An. "A room-temperature rechargeable dual-plating lithium–aluminium battery." Chemical Communications 57, no. 87 (2021): 11529–32. http://dx.doi.org/10.1039/d1cc03548g.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Dr., T. Shah, A. Gohiya Dr., N. Rai Dr., et al. "OutcomeAnalysis of dual plating in bicondylar fracture of Tibia." Orthopaedic Journal of M P Chapter 22, no. 2 (2016): 42–46. https://doi.org/10.5281/zenodo.3970741.

Full text
Abstract:
Background: The operative treatment of bicondylar fractures of tibial plateau remains a challenging job. Treatment goals include, restoration of articular congruity and alignment in the lower extremity and preservation of soft tissues and achieving functional range of knee motion. With multitude of surgical procedures available, there still remains ambiguity regarding the ideal approach for tibial plateau fractures. The aim of this study is to evaluate the functional outcome of dual plating via two incisions for bicondylar tibial plateau fractures. Methods: A prospective analytical cohort stud
APA, Harvard, Vancouver, ISO, and other styles
11

Vernekar, Anish, Waulden DeMelo, Ajmal Abdulla, Nehal Salgaokar, and Gauresh Vargaonkar. "Comparative study of functional outcome in single plating and dual plating of unstable distal femur fractures." Indian Journal of Orthopaedics Surgery 10, no. 2 (2024): 90–100. http://dx.doi.org/10.18231/j.ijos.2024.016.

Full text
Abstract:
Fractures of the distal femur remain challenging to treat as satisfactory outcome demands anatomical articular reduction, rigid and stable internal fixation along with early range of motion. The purpose of our study is to evaluate the functional outcome in patients with unstable fractures of the distal femur treated with single versus dual plating.: The study was a prospective study of 40 patients. The study was a prospective study of 40 patients (30 male and 10 female) with unstable fractures of the distal femur admitted to Goa medical college between June 2019 to June 2021 treated with open
APA, Harvard, Vancouver, ISO, and other styles
12

Alam, Intekhab. "Augmentation of clavicular fractures by dual plating." International Journal of Burns and Trauma 15, no. 3 (2025): 102–14. https://doi.org/10.62347/hwhh2373.

Full text
APA, Harvard, Vancouver, ISO, and other styles
13

Agarwala, Sanjay R., Mayank Vijayvargiya, and Avinashdev Devmani Upadhyay. "Achieving torsional stability of distal femur fractures through a single approach using 90–90 construct." BMJ Case Reports 17, no. 10 (2024): e258919. http://dx.doi.org/10.1136/bcr-2023-258919.

Full text
Abstract:
Distal femoral fractures (DFFs) are frequently characterised by significant comminution, osteoporosis, high implant failure, insufficient fixation because of a shortened distal part, non-union, malunion, and poor outcome. Our report presents two cases treated with dual plating in a 90–90 construct to achieve torsional stability. DFF fixation by dual plating in a 90–90 configuration proved to be a superior fixation similar to 90–90 plating for distal humerus fracture, since 90–90 plate fixation had significantly greater torque to failure load and has more resistance to torsional loading. Two ca
APA, Harvard, Vancouver, ISO, and other styles
14

Rijal, Sanjeeb, Jyoti Sitaula, Suman Basel, Bishnu Dev Sharma, Tej Prakash Dawadi, and Suman Lohani. "FUNCTIONAL AND RADIOLOGICAL OUTCOME OF TIBIAL PLATEAU SCHATZKER TYPE V AND TYPE VI TREATED WITH DUAL PLATING." Journal of Chitwan Medical College 11, no. 4 (2022): 131–34. http://dx.doi.org/10.54530/jcmc.432.

Full text
Abstract:
Background: The bicondylar fractures are common fractures. These high Energy fractures are associated with the various complications like malalignment, Varus collapse, Postoperative Stiffness, Wound complication. This Study aims to Study the Functional Outcome and stability of Dual Plating for these fractures.
 Methods: Total 25 cases of tibial plateau fractures V and VI treated with Dual Plating from 1st January 2016until 30th December 2019 in Chitwan Medical College Nepal were included in the Study. These fractures were operated with Anterolateral approach and Medial approach and Dual P
APA, Harvard, Vancouver, ISO, and other styles
15

Pandey, K. K., Ashok Vidyarthi, and Naveen Kumar Cholak. "ASSESMENT OF FUNCTIONAL OUTCOME OF DUAL PLATING FOR COMMINUTED DISTAL FEMUR FRACTURE." International Journal of Advanced Research 11, no. 04 (2023): 1300–1312. http://dx.doi.org/10.21474/ijar01/16792.

Full text
Abstract:
Background-Distal femur fractures are commonlyassociated with severemetaphysealcomminution and significant soft tissue injury.Locking plating is one of the best and modern options for treating supracondylar femur fractures with relatively low failure rates. Single lateral plating of distal femur fractures was often found to have a relatively higher failure. A medial platingin addition to lateral plating reduces the chances of failure of fixation and prevents varus collapse.The purpose of this study is toAssessment of Functional Outcome of Dual Plating For Comminuted Distal Femur Fracture. Mate
APA, Harvard, Vancouver, ISO, and other styles
16

Meignanaguru, Muthusaravakumar, Yogadeepan Dhakshinamurthi, Ganesh Ramesh Shetty, and Deepak Srinivasan. "Neglected Ipsilateral Non-Union Neck of Femur with Shaft of Femur Non-Union in A Young Patient and Its Management – A Rare Case Report." Journal of Orthopaedic Case Reports 14, no. 10 (2024): 90–95. http://dx.doi.org/10.13107/jocr.2024.v14.i10.4822.

Full text
Abstract:
Introduction: The incidence of ipsilateral neck of femur fracture with the shaft of femur going for non-union is not known. Management of this concomitant non-union can be a daunting task in terms of fixation strategy and its outcome. Case Report: In this article, we report a case of a 25-year-old male with ipsilateral neck of femur with shaft non-union. We have done open reduction and dual plating with bone grafting for the shaft of the femur followed by valgus subtrochanteric osteotomy with dynamic hip screw and impaction bone grafting for the neck of femur non-union. Conclusion: The main pr
APA, Harvard, Vancouver, ISO, and other styles
17

Kumar Babu, B. L. S., and Biju Ravindran. "Functional outcome after open reduction and internal fixation for traumatic diastasis of the pubic symphysis a one year follow-up study." International Journal of Research in Orthopaedics 2, no. 4 (2016): 256. http://dx.doi.org/10.18203/issn.2455-4510.intjresorthop20163548.

Full text
Abstract:
<p class="abstract"><strong>Background:</strong> Pubic diastasis often results in anteroposterior compression (APC) injuries based on Young and Burgess classification. It is caused due to high-energy trauma and of much clinical importance is given when coexists with urogenital and neurological complications with hemodynamic instability. Open reduction and internal fixation with plating facilitates early mobilisation with better results and is the preferable mode of stabilisation. We evaluated the clinical and functional outcome of such patients in a one-year follow-up period.
APA, Harvard, Vancouver, ISO, and other styles
18

Bates, R. I., and R. D. Arnell. "Alloy coatings by dual magnetron sputter barrel plating." Surface and Coatings Technology 68-69 (December 1994): 686–90. http://dx.doi.org/10.1016/0257-8972(94)90238-0.

Full text
APA, Harvard, Vancouver, ISO, and other styles
19

Patil, Siddaram N., Pandurangaiah Srinivas, and Divya Bhandary. "Prospective study of management of Schatzker’s type V & VI tibial plateau fractures by different types of plate osteosynthesis." International Journal of Research in Orthopaedics 3, no. 5 (2017): 1070. http://dx.doi.org/10.18203/issn.2455-4510.intjresorthop20173944.

Full text
Abstract:
<p class="abstract"><strong>Background:</strong> <span lang="EN-IN">Schatzker‘s type V and type VI fractures are bicondylar tibial plateau fractures which pose a challenge to the treating orthopaedician. Several studies have compared unilateral locked plate and double plating for their treatment and showed no statistically significant difference between these two fixation methods. So the quest for ideal implant for internal fixation (unilateral plating and dual plating) of these fractures continues. Hence we decided to do this study.</span></p><p class="a
APA, Harvard, Vancouver, ISO, and other styles
20

Zhao, H., L. Hou, J. X. Wu, and Y. X. Lu. "Fabrication of dual-side metal patterns onto textile substrates for wearable electronics by combining wax-dot printing with electroless plating." Journal of Materials Chemistry C 4, no. 29 (2016): 7156–64. http://dx.doi.org/10.1039/c6tc01979j.

Full text
APA, Harvard, Vancouver, ISO, and other styles
21

Li, Letong, Yanan Wang, Dongliang Guo, et al. "Pulse-Driven Internal Resistance Dynamics Enable Dual-Function Lithium-Plating Diagnosis and Longevity Enhancement in V2G-Optimized Lithium-Ion Batteries." Batteries 11, no. 5 (2025): 200. https://doi.org/10.3390/batteries11050200.

Full text
Abstract:
The lithium-plating phenomenon induced by low-temperature fast charging of lithium-ion batteries severely compromises their performance and safety. However, current lithium-plating detection methods predominantly rely on complex hardware systems with insufficient sensitivity, presenting significant challenges for implementation in increasingly prevalent Vehicle-to-Grid (V2G) scenarios. This study proposes a novel bidirectional pulse-current charging method designed to mitigate lithium plating and retard battery aging through intermittent pulse-current application. Experimental results verify a
APA, Harvard, Vancouver, ISO, and other styles
22

Moiz Hussain, Asad, Muhammad Shoaib Shoaib, Najeebullah Najeebullah, and Bilal Ahmad Qureshi. "Functional Outcomes in Dual Plating of Schatzker 5 and 6 Tibial Plateau Fractures." Indus Journal of Bioscience Research 2, no. 2 (2024): 437–44. http://dx.doi.org/10.70749/ijbr.v2i02.197.

Full text
Abstract:
Objectives The present research plan is to assess the functional and radiological outcomes of dual plating in the management of Schatzker type V and VI tibial plateau fractures and compare the technique's efficacy in promoting fracture union and functional recovery of the affected knee joint. Materials and Methods A comparative prospective controlled clinical study was undertaken in Schatzker type V and VI fractures patients. Both techniques incorporated dual plating, and the results were measured using the KSS and radiographic analysis. Forty consecutive male patients who underwent surgery fo
APA, Harvard, Vancouver, ISO, and other styles
23

Md., Farman Ali, Kumar Niraj, and Kumar Rakesh. "Functional Outcome of Distal Humerus Intercondylar Fractures Treated with Dual Plating." International Journal of Pharmaceutical and Clinical Research 16, no. 5 (2024): 1726–30. https://doi.org/10.5281/zenodo.12763783.

Full text
Abstract:
<strong>Background:&nbsp;</strong>Intercondylar fracture of the distal humerus is common injuries and present one of the most difficult challenges of fracture of lower end of humerus. The aim of this study to assess the functional outcome of humerus intercondylar fracture treated by dual plating using Mayo elbow performance score.&nbsp;<strong>Methods:&nbsp;</strong>This study was conducted at the Departments of Orthopaedics, Sri Krishna Medical College and Hospital, Muzaffarpur, Bihar from April 2019 to October 2021. Patients who had distal humerus fracture of AO classes 13C1, 13C2 and 13C3 w
APA, Harvard, Vancouver, ISO, and other styles
24

Sehgal, Amit, Saurabh Agarwal, Mahesh Kumar Navadaya, and Saurabh Shukla. "Evaluation of Functional Outcomes of Medial TENS Nailing with Lateral Locking Anatomical Plate Fixation for Complex Proximal Tibia Extra-articular Fracture." Journal of Orthopaedic Diseases and Traumatology 7, no. 2 (2024): 175–79. https://doi.org/10.4103/jodp.jodp_52_24.

Full text
Abstract:
Background: Comminution of articular surfaces and metaphyseal region, extensive soft-tissue injuries, infection, and risk of compartment syndrome are the challenging factors for management of complex proximal bicondylar tibial fractures. Various modalities such as cast, traction, or open reduction and internal fixation using single to dual plating are available for treating such types of fractures. We studied the results of lateral locking plate fixation with TENS nailing from the medial side for complex bicondylar proximal tibial fracture without posterior column involvement using a minimally
APA, Harvard, Vancouver, ISO, and other styles
25

Bora S., Shradha, Senthil L., Thiyagarajan U., Pradeep J. P., and Gokul Raj D. "Unusual medial tibial plateau fracture fixation using dual plating." International Journal of Research in Orthopaedics 5, no. 6 (2019): 1113. http://dx.doi.org/10.18203/issn.2455-4510.intjresorthop20194551.

Full text
Abstract:
&lt;p class="abstract"&gt;&lt;strong&gt;Background:&lt;/strong&gt; Medial tibial plateau fractures is a subtype of proximal tibial fractures that involve the articular surface and can present in several distinct patterns. Purpose of this study was to assess the clinical outcome of stabilizing these biplanar medial tibial plateau fractures using dual plating technique through a single incision.&lt;/p&gt;&lt;p class="abstract"&gt;&lt;strong&gt;Methods:&lt;/strong&gt; Between 2017 to 2019, 12 men and 8 women with closed medial tibial plateau fracture who underwent reconstruction using two plates
APA, Harvard, Vancouver, ISO, and other styles
26

Sono, Takashi, Akiyoshi Sagami, and Kazutaka Takatsuka. "Dual plating for bipolar clavicle fractures: A case report." Trauma Case Reports 34 (August 2021): 100494. http://dx.doi.org/10.1016/j.tcr.2021.100494.

Full text
APA, Harvard, Vancouver, ISO, and other styles
27

Ozkaya, Ufuk, and Atilla Sancar Parmaksizoglu. "Dual locked plating of unstable bicondylar tibial plateau fractures." Injury 46 (July 2015): S9—S13. http://dx.doi.org/10.1016/j.injury.2015.05.025.

Full text
APA, Harvard, Vancouver, ISO, and other styles
28

Deepak, Lamture, June Namdev, Suryavanshi Sachin, Sanap Balasaheb, and Lamture Yashwant. "Study of Functional Outcome of Proximal Tibia Plating in Intra-Articular Proximal Tibia Fracture-A Original Article." International Journal of Toxicological and Pharmacological Research 13, no. 8 (2023): 238–42. https://doi.org/10.5281/zenodo.11100611.

Full text
Abstract:
Proximal tibia fractures are treated with single medial, lateral, or dual plating, as well as an external fixator in some cases. Locking plates are now widely used, and fixing techniques are continually changing. From LISS, a less intrusive stabilizing system, to L.C.P., a periarticular locking compression plate system, to arthroscopic aided minimally invasive surgery, there is something for everyone. Because it lowers anatomical fracture and improves knee mobility, proximal tibia plating is the treatment of choice for these fractures. We investigated the functional result of plating-treated p
APA, Harvard, Vancouver, ISO, and other styles
29

Uhlig, Albrecht, Holger Bera, Cornelia Jaeger, and Dirk Rohde. "Plating Opportunities in 3D." Additional Conferences (Device Packaging, HiTEC, HiTEN, and CICMT) 2012, DPC (2012): 002228–50. http://dx.doi.org/10.4071/2012dpc-tha14.

Full text
Abstract:
Through Silicon Via's (TSV) are one of the key enabling technologies towards 3D packaging. Copper electroplating is frequently mentioned as candidate to fill TSV's besides polySi or ink-jetting conductive inks and attracts high attention. In addition to copper plating solder plating offers the next opportunity. Last but not least the ultimate target of an “all wet TSV” where also barrier and seed layers are electroplated, was demonstrated already. This paper targets to introduce the 3D related plating technologies and will encourage a discussion about targets to be meet in order to enable 3D.
APA, Harvard, Vancouver, ISO, and other styles
30

Modi, Dr Vishwas, Dr Prakash Bishnoi, and Dr Tirth Vyas. "Comparison of outcome of unilateral plating and dual plating in treatment of bicondylar tibia plateau fractures." International Journal of Orthopaedics Sciences 3, no. 3n (2017): 970–75. http://dx.doi.org/10.22271/ortho.2017.v3.i3n.141.

Full text
APA, Harvard, Vancouver, ISO, and other styles
31

DeBaun, Malcolm R., Michael J. Chen, Sean T. Campbell, et al. "Dual Mini-Fragment Plating Is Comparable With Precontoured Small Fragment Plating for Operative Diaphyseal Clavicle Fractures." Journal of Orthopaedic Trauma 34, no. 7 (2020): e229-e232. http://dx.doi.org/10.1097/bot.0000000000001727.

Full text
APA, Harvard, Vancouver, ISO, and other styles
32

Pastor, T., I. Zderic, T. Berk, et al. "NEW-GENERATION SUPERIOR SINGLE PLATING VERSUS LOW-PROFILE DUAL MINI-FRAGMENT PLATING OF DIAPHYSEAL CLAVICLE FRACTURES: A BIOMECHANICAL STUDY." Orthopaedic Proceedings 106-B, SUPP_2 (2024): 107. http://dx.doi.org/10.1302/1358-992x.2024.2.107.

Full text
Abstract:
Recently, a new generation of superior clavicle plates was developed featuring the variable-angle locking technology for enhanced screw positioning and optimized plate-to-bone fit design. On the other hand, mini-fragment plates used in dual plating mode have demonstrated promising clinical results. However, these two bone-implant constructs have not been investigated biomechanically in a human cadaveric model. Therefore, the aim of the current study was to compare the biomechanical competence of single superior plating using the new generation plate versus dual plating with low-profile mini-fr
APA, Harvard, Vancouver, ISO, and other styles
33

Qureshi, Bilal Ahmad, Ahmad Mushtaq Khan, and Hafiz Faiz ur Rehman. "Comparison of Clinical Outcomes of Orthogonal Versus Single Posterior Plating for Internal Fixation of Distal Humeral Extra-Articular Fractures." Pakistan Armed Forces Medical Journal 75, SUPPL-2 (2025): S140—S145. https://doi.org/10.51253/pafmj.v75isuppl-2.11068.

Full text
Abstract:
Objective: Complications are frequently linked to traditional treatment strategies for distal humeral fractures such as dual column plating. The study's objective is to compare outcomes of osteosynthesis by a single dorsolateral plate in extra-articular distal humeral fractures with conventional bi-columnar fixation in terms of clinical results and radiological union. Study Design: Prospective Comparative Study. Place and Duration of Study: Department of Orthopedic Surgery, Combined Military Hospital, Rawalpindi Pakistan, from Oct 2022 to Sep 2023. Methodology: Forty skeletally matured patient
APA, Harvard, Vancouver, ISO, and other styles
34

Shrestha, Dinesh, and Merina Shrestha. "Outcome of Dual 90-90 Plating in Intercondylar Fractures of Distal Humerus in Adults." Journal of Nepalgunj Medical College 16, no. 2 (2018): 23–26. http://dx.doi.org/10.3126/jngmc.v16i2.24868.

Full text
Abstract:
Background: Intercondylar fracture of distal humerus are very difficult to manage. It needs proper anatomic reconstruction and rigid fixation.&#x0D; Aims and Objectives of study: Evaluation of outcome of dual bicolumnar 90-90 plating of AO type 13C fractures of distalhumerus in adult.&#x0D; Material and method: In a prospective hospital based study on 16 patients with a mean age of 33.37 years ± SD8.30, who presented with intercondylar fracture of distal hummers were studied between July 2015 to December 2017. All patients were graded according to AO classification. Out of 16 patients 5 were i
APA, Harvard, Vancouver, ISO, and other styles
35

Hou, Nianzong, Haiyang Zhang, Mingjian Bai, Hao Chen, Weidong Song, and Liming Wang. "The Old Supracondylar Fracture of Femur Treated by Gradual Deformity Correction Using the Ilizarov Technique Followed by the Second-Stage Internal Fixation in an Elderly Patient With Osteoporosis." Geriatric Orthopaedic Surgery & Rehabilitation 11 (January 1, 2020): 215145932093167. http://dx.doi.org/10.1177/2151459320931673.

Full text
Abstract:
Background: The supracondylar nonunion of femur in elderly individuals is rare and challenging to manage. Nothing in English literatures or guidelines is available regarding this particular fracture characterized by osteoporosis, soft-tissue contracture, shortening, and joint stiffness. We report a case of an elderly patient with a supracondylar nonunion of the femur, which was successfully treated using staged Ilizarov techniques and dual plating. Case Presentation: An 84-year-old female patient was admitted to our orthopedic department for her pain and soft-tissue swelling around the right k
APA, Harvard, Vancouver, ISO, and other styles
36

Rusimov, Lyubomir. "Dual plate fixation of unstable proximal humerus fractures: A Narrative review." Bulgarian Society of Medical Sciences Journal 7 (May 19, 2025): e144938. https://doi.org/10.3897/bsms.7.144938.

Full text
Abstract:
Introduction: Medial column instability has been identified as a key factor contributing to the increased failure rates observed after locking plate (LP) fixation for unstable proximal humerus fractures (PHFs). Recent studies have reported promising biomechanical and clinical outcomes with the use of LP fixation augmented by an additional plate for medial column stabilization. The current article provides an overview of the available clinical literature for dual plate fixation of unstable PHFs with medial column instability. Materials and methods: For the arrangement of this narrative, non-sys
APA, Harvard, Vancouver, ISO, and other styles
37

Mohammed Jaffer Jawad Al-Musawei, Mohamed Abdul Aziz, and Ahmed Sarhan Mzyon. "Evaluation of functional outcome using dual plating in treatment of intra-articular distal humerus fractures in adults." Journal of the Pakistan Medical Association 74, no. 10 (Supple-08) (2024): S368—S374. http://dx.doi.org/10.47391/jpma-bagh-16-84.

Full text
Abstract:
Of all the humerus fractures in adults, 30% are of the distal end of the bone. The dual plate is strong biomechanically. The current study was conducted at Al-Yarmouk Teaching Hospital, Baghdad, Iraq, between July 1, 2019 to July 1, 2021 to study the role of dual plating in intra-articular distal humerus fractures.Included were 20 adult patients, all with intra articular fracture of the distal humerus and treated and evaluatedby open reduction and internal fixation technique using dual locking plating. Clinically the final results wereassessed using the Mayo Elbow Performance Score (MEPS). The
APA, Harvard, Vancouver, ISO, and other styles
38

Lin, Yu-Hsing, Ramesh Subramani, Yu-Ting Huang, et al. "Highly stable interface formation in onsite coagulation dual-salt gel electrolyte for lithium-metal batteries." Journal of Materials Chemistry A 9, no. 9 (2021): 5675–84. http://dx.doi.org/10.1039/d0ta12208d.

Full text
APA, Harvard, Vancouver, ISO, and other styles
39

Citak, Caner, Cemil Kayali, Firat Ozan, Taskin Altay, Huseyin Gokhan Karahan, and Kamil Yamak. "Lateral Locked Plating or Dual Plating: A Comparison of Two Methods in Simple Bicondylar Tibial Plateau Fractures." Clinics in Orthopedic Surgery 11, no. 2 (2019): 151. http://dx.doi.org/10.4055/cios.2019.11.2.151.

Full text
APA, Harvard, Vancouver, ISO, and other styles
40

Mittal, KrishnaKumar, Apoorva Agarwal, and Raj Nishant. "Post Plating Aseptic Non Union of Diaphyseal Fractures of Long Bones - A Treatment Protocol by Dual Plating." Journal of Bone and Joint Diseases 36, no. 1 (2021): 7. http://dx.doi.org/10.13107/jbjd.2021.v36i01.039.

Full text
APA, Harvard, Vancouver, ISO, and other styles
41

Mittal, Krishna Kumar, Apoorva Agarwal, and Nishant Raj. "Management of Refractory Aseptic Subtrochanteric Non-union by Dual Plating." Indian Journal of Orthopaedics 55, no. 3 (2021): 636–45. http://dx.doi.org/10.1007/s43465-020-00318-w.

Full text
APA, Harvard, Vancouver, ISO, and other styles
42

Flint, Wesley W., Christopher B. Hirose, and Michael J. Coughlin. "Ankle Arthrodesis Using an Anterior Titanium Dual Locked Plating Construct." Journal of Foot and Ankle Surgery 56, no. 2 (2017): 304–8. http://dx.doi.org/10.1053/j.jfas.2016.10.019.

Full text
APA, Harvard, Vancouver, ISO, and other styles
43

Kassab, Mostafa Elsayed, Mohamed Roshdy El-Tabakh, Abd Elhafez Abd Elhafez Megahed, and Mostafa Ahmed Ayoub. "Outcome of dual plating in comminuted unstable distal femur fractures." International Journal of Orthopaedics Sciences 10, no. 2 (2024): 265–72. http://dx.doi.org/10.22271/ortho.2024.v10.i2d.3564.

Full text
APA, Harvard, Vancouver, ISO, and other styles
44

Cho, Chul-Hyun, Kwang-Yeung Jeong, and Beom-Soo Kim. "Posterior Dual Plating for Distal Shaft Fractures of the Humerus." Journal of the Korean Fracture Society 30, no. 3 (2017): 117. http://dx.doi.org/10.12671/jkfs.2017.30.3.117.

Full text
APA, Harvard, Vancouver, ISO, and other styles
45

Hase, Alan, Yousuke Sato, Keisuke Shinohara, and Kentaro Arai. "Identification of the Wear Process of a Silver-Plating Layer by Dual Acoustic Emission Sensing." Coatings 11, no. 6 (2021): 737. http://dx.doi.org/10.3390/coatings11060737.

Full text
Abstract:
A method based on acoustic emission (AE) sensing in which two AE sensors are used to measure the tribological characteristics of two interacting friction materials simultaneously in real time was assessed for the in situ measurement and evaluation of the wear process of silver plating. AE sensors were attached to a silver-plated pin and a silver-plated plate, and the two AE signals were measured simultaneously on a pin-on-plate-type reciprocating sliding tester. The resulting changes in the AE signal could be classified into three phases. Surface observations and energy-dispersive X-ray spectr
APA, Harvard, Vancouver, ISO, and other styles
46

Xiang, Jing, Chong Wang, Yuanming Chen, et al. "Numerical simulation and experiments to improve throwing power for practical PCB through-holes plating." Circuit World 45, no. 4 (2019): 221–30. http://dx.doi.org/10.1108/cw-05-2018-0033.

Full text
Abstract:
Purpose The purpose of this study is to investigate the synergism of convection, current density distribution and additives by numerical simulation and electrochemical experiments for good throwing power (TP) of copper electro-deposition in printed circuit board (PCB) manufacture. Design/methodology/approach The flow field of THs and current density distribution on various AR of THs are calculated and analyzed. Meanwhile, corresponding simulation is used to study the performance of plating electrolytes on TP. Two electrochemical parameters, overpotential (η) and potential difference (△η), are
APA, Harvard, Vancouver, ISO, and other styles
47

Hussien, Mohammed A., Qassem T. Abdelsattar, Ahmed Elbadrawi, and Ahmed K. El Ghazawy. "Hybrid fixation of diaphyseal both bone forearm fracture versus dual plating in adolescence." Egyptian Orthopaedic Journal 59, no. 4 (2024): 691–99. https://doi.org/10.4103/eoj.eoj_73_24.

Full text
Abstract:
Purpose To compare the clinical and radiological outcomes of hybrid fixation with its two types, versus dual plating in diaphyseal both bone forearm (BBF) fractures in adolescents. Methods A retrospective comparative study was carried out on 31 adolescents with a mean age of 13 years with BBF diaphyseal fractures (AO Foundation [AO]/Orthopaedic Trauma Association [OTA] 22-A3) managed by hybrid fixation (group A) or dual plating (group B). Evaluation included operative time, blood loss, time to union, range of motion, Price functional grading, and complications. Results The mean follow-up perio
APA, Harvard, Vancouver, ISO, and other styles
48

Mistry, Janak, Tejas Patel, and Parth Patel. "Distal humerus fracture and its surgical management with distal humerus dual plating." National Journal of Physiology, Pharmacy and Pharmacology 14, no. 4 (2023): 1. http://dx.doi.org/10.5455/njppp.2023.13.08397202322082023.

Full text
Abstract:
Background: Approximately 7% of all adult fractures involve the elbow. Out of these, approximately 1/3 involve the distal humerus. These fractures have bimodal age distribution with peak incidences between the age 12 and 19 years and aged more than 80 years. The result of these fractures relies on the location of the fracture, the type of fracture (comminute or simple), any displacement, and any soft-tissue damage in the immediate vicinity. Distal humerus fracture can be treated surgically using a variety of techniques, including open reduction and internal fixation with plates, limited intern
APA, Harvard, Vancouver, ISO, and other styles
49

Randall, Rachel M., Tara Nagle, Andrew Steckler, Damien Billow, and Mark J. Berkowitz. "Dual Nonlocked Plating as an Alternative to Locked Plating for Comminuted Distal Fibula Fractures: A Biomechanical Comparison Study." Journal of Foot and Ankle Surgery 58, no. 5 (2019): 916–19. http://dx.doi.org/10.1053/j.jfas.2019.01.017.

Full text
APA, Harvard, Vancouver, ISO, and other styles
50

Dr., Surendra Singh Yadav, Sameer Gupta Dr., Prashant B. Patel Dr., Swami Pravin Dr., and Chetan Singh Dhosariya Dr. "The outcome of Complex Tibial plateau fractures (Schatzker type V and VI) treated with Dual plates." Orthopaedic Journal of M P Chapter 24, no. 2 (2018): 78–82. https://doi.org/10.5281/zenodo.3970107.

Full text
Abstract:
Background: Isolated lateral locked plating does not provide sufficient fixation to resist collapse of the medial condyle, leading to loss of axial alignment of the limb, producing varus deformity and poor long-term outcome. dual locked plating of bicondylar tibial plateau fractures are required to reduces the risk of mal-reduction and loss of reduction and prevents post traumatic osteoarthritis. Hence we evaluated functional and radiological outcome of dual locking plates in proximal tibial plateau fractures Schatzker type V and VI. Material &amp; Methods: Twenty-two cases of tibial plateau f
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!