To see the other types of publications on this topic, follow the link: E-etching.

Dissertations / Theses on the topic 'E-etching'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 50 dissertations / theses for your research on the topic 'E-etching.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.

1

Orf, Bryan J. "Comparison of advanced resist etching In e-beam generated plasmas." College Park, Md. : University of Maryland, 2006. http://hdl.handle.net/1903/3660.

Full text
Abstract:
Thesis (M.S.) -- University of Maryland, College Park, 2006.
Thesis research directed by: Dept. of Materials Science and Engineering. Title from t.p. of PDF. Includes bibliographical references. Published by UMI Dissertation Services, Ann Arbor, Mich. Also available in paper.
APA, Harvard, Vancouver, ISO, and other styles
2

Macedo, Maria Gracinda Ferreira Pereira de. "Integridade da camada de adesivo em diferentes áreas topográficas da dentina, utilizando sistemas de adesão de total ecthing e self-etching." Dissertação, Faculdade de Medicina Dentária da Universidade do Porto, 2009. http://hdl.handle.net/10216/61052.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Macedo, Maria Gracinda Ferreira Pereira de. "Integridade da camada de adesivo em diferentes áreas topográficas da dentina, utilizando sistemas de adesão de total ecthing e self-etching." Master's thesis, Faculdade de Medicina Dentária da Universidade do Porto, 2009. http://hdl.handle.net/10216/61052.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Saavedra, Guilherme de Siqueira Ferreira Anzaloni. "Efeito da neutralização e limpeza sônica do precipitado do ácido fluorídrico sobre a resistência de união entre uma cerâmica feldspática e um cimento resinoso /." São José dos Campos : [s.n.], 2006. http://hdl.handle.net/11449/97416.

Full text
Abstract:
Orientador: Estevão Tomomitsu Kimpara
Banca: Rander Pereira Avelar
Banca: Tarcisio José de Arruda Paes
Resumo: O objetivo deste trabalho foi avaliar três hipóteses: a) o processo de neutralização influencia nos valores de resistência de união entre uma cerâmica feldspática e um cimento resinoso; b) limpeza sônica dos precipitados do ácido fluorídrico aumenta os valores de resistência de união; c) associação entre o do processo de neutralização e a limpeza sônica melhora a resistência de união. Confeccionou-se 32 blocos cerâmicos (VM7 VITA Zahnfabrik), os quais foram duplicados em resina composta (W3D Master). Os resultados deste estudo confirmaram que: a) o processo de neutralização influencia nos valores de resistência de união entre uma cerâmica feldspática e um cimento resinoso; b) a limpeza sônica dos precipitados do ácido fluorídrico aumenta os valores de resistência de união; c) a associação entre o processo de neutralização e a limpeza sônica melhora a resistência de união.
Abstract: This study evaluated three hypotheses: a) the neutralization process influences the bond strength values between a feldspar ceramic and a resin cement; b) ultrasonic cleaning of hydrofluoric acid precipitates increases the bond strength values; c) association between the neutralization process and ultrasonic cleaning improves the bond strength. The present results confirmed that: a) the neutralization process influences the bond strength values between a feldspar ceramic and a resin cement; b) ultrasonic cleaning of hydrofluoric acid precipitates increases the bond strength values; c) association between the neutralization process and ultrasonic cleaning improves the bond strength.
Mestre
APA, Harvard, Vancouver, ISO, and other styles
5

Camargo, Janine Sanches Gonzaga de. "Modificação da molhabilidade da celulose por processos subsequentes de ablação e deposição a plasma." Universidade Federal de São Carlos, 2017. https://repositorio.ufscar.br/handle/ufscar/9001.

Full text
Abstract:
Submitted by Milena Rubi (milenarubi@ufscar.br) on 2017-08-16T16:54:47Z No. of bitstreams: 1 CAMARGO_Janine_2017.pdf: 19878018 bytes, checksum: 517c1918bf6801b10fe87b0d806d8a50 (MD5)
Approved for entry into archive by Milena Rubi (milenarubi@ufscar.br) on 2017-08-16T16:55:38Z (GMT) No. of bitstreams: 1 CAMARGO_Janine_2017.pdf: 19878018 bytes, checksum: 517c1918bf6801b10fe87b0d806d8a50 (MD5)
Approved for entry into archive by Milena Rubi (milenarubi@ufscar.br) on 2017-08-16T16:55:44Z (GMT) No. of bitstreams: 1 CAMARGO_Janine_2017.pdf: 19878018 bytes, checksum: 517c1918bf6801b10fe87b0d806d8a50 (MD5)
Made available in DSpace on 2017-08-16T16:55:50Z (GMT). No. of bitstreams: 1 CAMARGO_Janine_2017.pdf: 19878018 bytes, checksum: 517c1918bf6801b10fe87b0d806d8a50 (MD5) Previous issue date: 2017-03-14
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Cellulose is a biopolymer available in abundance in nature, which presents very interesting properties mainly for the textile, packaging and paper industry. However, due to its strongly hydrophilic character, resulting from the presence of a large number of free hydroxyl groups in its molecule, its use in certain areas becomes limited. In order to promote the modification of the wetting characteristic of the cellulose, and make it superhydrophobic, samples of this material were submitted to plasma processes performed in two steps: ablation and film deposition. Initially, the effect of variation of ablation time on the creation of adequate surface topography was studied. For this, the samples were exposed to the oxygen plasma at a pressure of 13 Pa and power of 150 W, varying the treatment time from 5 to 60 minutes. Then, the treated samples were submitted to the process called PECVD (Plasma Enhanced Chemical Vapor Deposition), in which a film was deposited on the surface from the precursor hexamethyldisiloxane (HMDSO) in the presence of argon, in a ratio of 70 e 30%, respectively. The deposition time was set to 30 minutes and the power applied was 150 W. In a second investigation, the effect of the thickness of the deposited film was studied. In this case, the cellulose samples were previously exposed to the oxygen ablation plasma for 60 minutes and then led to the PECVD process, with the deposition time varying from 5 to 30 minutes. In a third investigation, the duration of the ablation and deposition steps was reduced to 30 and 1 minute, respectively, in order to optimize the methodology. The samples were characterized by Scanning Electron Microscopy (SEM), Energy Dispersive Spectroscopy (EDS), Fourier Transform Infrared Spectroscopy (FTIR), profilometry, static contact angle measurements and hysteresis and sliding angle measurements. The results demonstrated that longer exposure times for the ablation step provide a significant modification in the material, through the creation of nanoscale structures on the surface of the fibers. The deposition step promoted the formation of films with organosilicon character on the cellulose surface, with thicknesses varying between 144 and 910 nm. The combination of the topography created after 30 minutes of ablation with the thin film resulting from the deposition step for 1 minute provided a surface with low receptivity for both polar (? = 150°) and nonpolar (? ~ 120°) liquids, whose wettability property remained stable with treatment aging time. The low values obtained for hysteresis (9°) and sliding angle (7°) confirm the creation of a superhydrophobic roll-off surface.
A celulose é um biopolímero disponível em abundância na natureza e que possui propriedades bastante interessantes principalmente para a indústria têxtil, de embalagens e papel. No entanto, devido ao seu caráter fortemente hidrofílico, proveniente da presença de um grande número de grupos hidroxila livres em sua molécula, sua utilização em determinadas áreas se torna limitada. Com o objetivo de promover a modificação da característica de molhabilidade da celulose, de modo a torná-la superhidrofóbica, amostras deste material foram submetidas a processos a plasma realizados em duas etapas: ablação e deposição de filme. Inicialmente, estudou-se o efeito da variação do tempo de ablação na criação da topografia adequada da superfície. Para isto, as amostras foram expostas ao plasma de oxigênio a uma pressão de 13 Pa e 150 W de potência, variando-se o tempo de tratamento de 5 a 60 minutos. Em seguida, as amostras tratadas foram submetidas ao processo denominado PECVD (Plasma Enhanced Chemical Vapor Deposition), no qual foi depositado um filme sobre a superfície das mesmas, a partir do precursor hexametildisiloxano (HMDSO) na presença de argônio, numa proporção de 70 e 30%, respectivamente. O tempo de deposição foi fixado em 30 minutos e a potência aplicada foi de 150 W. Numa segunda investigação, foi estudado o efeito da espessura do filme depositado. Neste caso, as amostras de celulose foram previamente expostas ao plasma de ablação com oxigênio durante 60 minutos e posteriormente ao processo de PECVD, variando-se o tempo de deposição de 5 a 30 minutos. Numa terceira investigação, o tempo de duração das etapas de ablação e deposição foi reduzido para 30 e 1 minuto, respectivamente, com o intuito de otimizar a metodologia. As amostras foram caracterizadas por Microscopia Eletrônica de Varredura (MEV), Espectroscopia de Energia Dispersiva (EDS), Espectroscopia de Absorção no Infravermelho por Transformada de Fourier (FTIR), perfilometria, medição de ângulo de contato estático e medição de histerese e ângulo de deslizamento. Os resultados demonstraram que maiores tempos de exposição à etapa de ablação proporcionam uma modificação significativa no material, por meio da criação de estruturas em nanoescala na superfície das fibras. A etapa de deposição promoveu a formação de filmes de caráter organosilicone sobre a superfície da celulose, com espessuras variando entre 144 e 910 nm. A combinação entre a topografia criada após 30 minutos de ablação e o filme de menor espessura resultante da etapa de deposição durante 1 minuto, possibilitaram a obtenção de uma superfície de baixa receptividade tanto a líquidos polares (? =150°) quanto apolares (? ~120°), cuja propriedade de molhabilidade se manteve estável com o tempo de envelhecimento. Os baixos valores de histerese (9°) e ângulo de deslizamento (7°) obtidos confirmam a criação de uma superfície superhidrofóbica do tipo “roll-off”.
APA, Harvard, Vancouver, ISO, and other styles
6

Azevedo, Paola Cristine Almeida. "Gravura em luz : uma possibilidade holistica da calcogravura e a holografia." [s.n.], 2007. http://repositorio.unicamp.br/jspui/handle/REPOSIP/284315.

Full text
Abstract:
Orientador: Jose Joaquim Lunazzi
Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Artes
Made available in DSpace on 2018-08-10T03:37:00Z (GMT). No. of bitstreams: 1 Azevedo_PaolaCristineAlmeida_D.pdf: 3042587 bytes, checksum: 6e2407a885f75cbe4b90031a1cadd1f1 (MD5) Previous issue date: 2007
Resumo: Esta pesquisa objetivou criar e refletir sobre o alargamento de linguagens usadas na arte e a tecnologia como parâmetros de criação de um trabalho em poéticas visuais. Para estruturar esses conceitos, foram levantadas leituras referentes à mudança paradigmática da segunda metade do século XX relativa ao campo da física quântica, assim como a retomada de uma postura unificadora das áreas do conhecimento proposta pela visão holística. Dessa maneira, no tratamento empírico realizaram-se os trabalhos poéticos considerados ? as hologravuras ? com objetivo de aproximar o observador de um estado de percepção maior ao vivido cotidianamente, com ênfase na fenomenologia da percepção, descrita e recorrente na produção de artistas nas últimas cinco décadas. O trabalho tem quatro partes. A primeira é dedicada às questões teóricas; a segunda ao histórico dos meios técnicos calcogravura e holografia; no terceiro a recorrência da fenomenologia e a utilização da linha como elementos pertinentes na ambientação do trabalho artístico, como método comparativo, nas duas últimas partes, uso das obras de artistas consolidados na área que fazem aproximações com esta pesquisa; na quarta e última parte, relato a produção empírica desta pesquisa envolvendo questões de imaterialidade do trabalho e sua relação frente à arte contemporânea. Esta pesquisa tem aplicações pertinentes a um estado de reflexão e sistematização em termos científicos na produção de trabalhos em poéticas visuais; as hipóteses aqui levantadas são compatíveis com os resultados alcançados no que se refere a um alargamento das linguagens artísticas usando como recurso a arte e a tecnologia, pois os trabalhos desenvolvidos a partir daí incluem informação científica e tecnológica, mas é atualizada dentro de moldes poéticos próprios, tornando-se exemplo do que é possível fazer: unir dois campos do conhecimento.Nesse sentido, buscando uma conscientização de dentro para fora, a fenomenologia pode ser tomada como modelo pelas artes que lidam com a tecnologia
Abstract: The present research project entitled Light Etchings; a Holistic Possibility of Calcogravure and Holography has as it?s main objective to reflect upon the widening of languages through the fusion of art and technology emphasizing these two quite different approaches as parameters for the creation of a visual poetics. In order to mount these concepts, readings regarding the paradigmatic changes in the area of Quantum Physics during the second half of the twentieth century became instrumental especially when placed in context to the vision proposed by Holistic Theory. In this way, in what regards empirical treatment, a number of Holoetchings (Hologravura) were elaborated with the objective of bringing the observer to a higher state of observation than that normally experienced and thus emphasizing methods recurrent in the production of artists during the past five decades regarding the phenomenology of perception. The work is organized in four parts. The first, dedicated to theoretical questions, the second to the technical aspects of metal engraving and holography, the third to the recurrence of phenomenology and the use of linearity as pertinent elements in the environment of the artistic work, as a comparative method in the last two parts I use the works of established artists whose work border this research, and in the fourth part, a description of the empirical work of this research involving questions of the immateriality of the work and it?s relation to contemporary art. This research has pertinent applications in relation to the reflection and systematization in scientific terms in relation to works in visual poetics, to the hypotheses here proposed which are compatible to the results obtained pertinent to the widening of artistic languages using as resources art and technology since works effected from that point contain information which is both scientific and technological, but brought up-to date within definite poetic molds, becoming thus, an example of what it is possible to achieve by blending two fields of knowledge. In this sense, searching for concicousness from inside out, phenomenology can be taken as a model by arts that deal with technology
Doutorado
Artes Visuais
Mestre em Artes
APA, Harvard, Vancouver, ISO, and other styles
7

Coppini, Erick Kamiya 1989. "Influence of enamel acid-etching on mechanical properties and nanoleakage of resin composite restorations after thermomechanical aging = Influência do condicionamento ácido do ângulo cavosuperficial nas propriedades mecânicas e nanoinfiltração de restaurações após envelhecimento termomecânico." [s.n.], 2013. http://repositorio.unicamp.br/jspui/handle/REPOSIP/289649.

Full text
Abstract:
Orientador: Luís Alexandre Maffei Sartini Paulillo
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-24T07:41:05Z (GMT). No. of bitstreams: 1 Coppini_ErickKamiya_M.pdf: 3349153 bytes, checksum: e0323d6512c30cee2e8ea17128a4c6e6 (MD5) Previous issue date: 2013
Resumo: The aim of this study was to evaluate the cavosuperficial enamel acid-etching influence in class I cavities, filled with composites on microtensile bond strength, Knoop microhardness and nanoleakage after thermomechanic ageing. It was selected 76 sound molar splitted on: 32 teeth to microtensile test (n=8); 32 teeth to Knoop microhardness (n=8); and 12 teeth (n=3) to nanoleakage analysis. The cavities were prepared on a standard cavity preparation machine. Half of the teeth had the cavosuperficial enamel etched with 35% phosphoric acid and restored with a Silorane restorative system or a Methacrylate restorative system. After the conclusion of the restoration procedures, the teeth were taken to a thermomechanic cycling machine where the artificial ageing was performed with 200.000 mechanical cycles with an 80 N load in a 2HZ frequency and thermocycling by filling the chambers for 30 seconds and 15 seconds drainage with the temperatures varying between 5ºC and 55ºC. The samples were submitted to the microtensile bond strength test, Knoop microhardness and nanoleakage evaluation. To statistical analysis it was performed the ANOVA two-way and Tuckey test (p ? 0,05). The group restored with methacrylate without acid-etching showed the lowest values of microtensile bond strength and it was statistically different to the other groups that have no difference between them. The methacrylate composite presented statistically higher values on Knoop microhardness compared to silorane composite. The nanoleakage analysis showed low infiltration to silorane restorative system and moderate infiltration to the methacrylate restorative system. The methacrylate group restored without enamel acid-etching showed the formation of Water Trees. It can be concluded that the acid-etching improved the bond strength to the methacylate system. The methacrylate composite has bigger Knoop microhardness than silorane composite. The methacrylate restorative system showed moderate infiltration on nanoleakage analysis
Abstract: The aim of this study was to evaluate the cavosuperficial enamel acid-etching influence in class I cavities, filled with composites on microtensile bond strength, Knoop microhardness and nanoleakage after thermomechanic ageing. It was selected 76 sound molar splitted on: 32 teeth to microtensile test (n=8); 32 teeth to Knoop microhardness (n=8); and 12 teeth (n=3) to nanoleakage analysis. The cavities were prepared on a standard cavity preparation machine. Half of the teeth had the cavosuperficial enamel etched with 35% phosphoric acid and restored with a Silorane restorative system or a Methacrylate restorative system. After the conclusion of the restoration procedures, the teeth were taken to a thermomechanic cycling machine where the artificial ageing was performed with 200.000 mechanical cycles with an 80 N load in a 2HZ frequency and thermocycling by filling the chambers for 30 seconds and 15 seconds drainage with the temperatures varying between 5ºC and 55ºC. The samples were submitted to the microtensile bond strength test, Knoop microhardness and nanoleakage evaluation. To statistical analysis it was performed the ANOVA two-way and Tuckey test (p ? 0,05). The group restored with methacrylate without acid-etching showed the lowest values of microtensile bond strength and it was statistically different to the other groups that have no difference between them. The methacrylate composite presented statistically higher values on Knoop microhardness compared to silorane composite. The nanoleakage analysis showed low infiltration to silorane restorative system and moderate infiltration to the methacrylate restorative system. The methacrylate group restored without enamel acid-etching showed the formation of Water Trees. It can be concluded that the acid-etching improved the bond strength to the methacylate system. The methacrylate composite has bigger Knoop microhardness than silorane composite. The methacrylate restorative system showed moderate infiltration on nanoleakage analysis
Mestrado
Dentística
Mestre em Clínica Odontológica
APA, Harvard, Vancouver, ISO, and other styles
8

Freitas, Marcela Santiago 1987. "Effect of pre-etching to enamel and dentin on bond strength and interfacial morphology of different adhesives systems = Efeito do pré-condicionamento ácido do esmalte da dentina na resistência de união e morfologia de interface de diferentes sistemas adesivos." [s.n.], 2013. http://repositorio.unicamp.br/jspui/handle/REPOSIP/288307.

Full text
Abstract:
Orientadores: Mirela Sanae Shinohara, Mário Fernando de Góes
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-21T23:51:52Z (GMT). No. of bitstreams: 1 Freitas_MarcelaSantiago_M.pdf: 38797129 bytes, checksum: 16869befa66eba198d1cb13ad5c9ac1d (MD5) Previous issue date: 2013
Resumo: Estudos mostram que a resistência de união (RU) alcançada pelos sistemas adesivos autocondicionantes em superfície de esmalte pré-condicionado é significativamente maior se comparada aos valores obtidos em esmalte não condicionado. A partir destas evidências, este estudo teve como objetivo avaliar a RU e a morfologia da interface adesiva (MI) em esmalte e dentina de um adesivo autocondicionante de passo único multi-mode e um adesivo autocondicionante de dois passos com e sem pré-condicionamento ácido da superfície comparado a dois sistemas adesivos de condicionamento total, de dois e três passos. Terceiros molares humanos recém-extraídos foram seccionados para obtenção de superfícies planas em esmalte e dentina, as quais foram desgastadas com lixa SiC #600 para padronização da smear layer. Estas amostras foram divididas aleatoriamente em 6 grupos: (SBU) Scotchbond Universal; (SBUcond) SBU précondicionado; (CSE) Clearfil SE Bond; (CSEcond) CSE pré-condicionado; (SBMP) Scotchbond Multi-Purpose; e (EX) Excite F. Os grupos de condicionamento total e os autocondicionantes a serem avaliados com pré-condicionamento receberam a aplicação do ácido fosfórico por 15s em dentina e 30s em esmalte. Todos os sistemas adesivos foram aplicados de acordo com as recomendações dos fabricantes. Em seguida, um bloco de resina composta (Filtek Supreme Plus) foi construído incrementalmente sobre cada superfície preparada para o teste de RU, e para a MI, as superfícies foram restauradas com resina flow (Filtek Z-350 Flowable Restorative) formando um "sanduíche", de esmalte ou dentina. Após 24h, para avaliação da RU, as amostras foram seccionadas em palitos com área transversal de 0,8mm2 e submetidos ao teste de microtração com velocidade de 1,0mm/min. Os resultados foram analisados estatisticamente pelos testes one-way ANOVA e Fisher's PLSD (?=0.05) e os padrões de fratura analisados em Microscopia Eletrônica de Varredura (MEV). Para análise da MI, duas amostras de cada grupo foram incluídas em resina epóxica, polidas e observadas em MEV. Para esmalte, os resultados de RU mostraram que o SBUcond e CSEcond obtiveram os maiores valores, seguidos dos grupos SBMP, SBU e CSE que não apresentaram diferenças entre si. O grupo EX obteve os menores valores comparados aos outros grupos. Na análise da MI, os grupos SBUcond e CSEcond apresentaram nítidas extensões do adesivo penetrado no esmalte desmineralizado, semelhante aos sistemas de condicionamento total. Já para dentina, os resultados de RU mostraram que o condicionamento ácido prévio diminuiu significativamente os valores de RU dos sistemas autocondicionantes. Os maiores valores foram obtidos pelo SBU, CSE e SBMP, com valores de RU estatisticamente equivalentes entre si. Como em esmalte, o sistema adesivo EX obteve os menores valores. A análise em MEV da MI mostrou que o condicionamento prévio da dentina com adesivos autocondicionantes forma uma camada híbrida mais espessa com formação de tags resinosos, semelhantes aos sistemas adesivos de condicionamento total. Pode-se concluir que em esmalte, o condicionamento prévio aumentou significativamente os valores de RU para os sistemas autocondicionantes. Contudo, estes sistemas adesivos não apresentaram diferença estatística do adesivo convencional SBMP. E para dentina, o pré-condicionamento dos adesivos autocondicionantes diminuiu significativamente os valores de RU, entretanto, os valores de SBUcond não foram diferentes significativamente dos obtidos pelo sistema adesivo convencional SBMP
Abstract: Studies show that the bond strength (BS) achieved by self-etching adhesive systems on pre-etched enamel surface is significantly higher compared with the values obtained on unetched enamel. From this evidence, this study aimed to assess the BS and morphology of the adhesive interface (AI) on enamel and dentin of a one-step self-etching adhesive multi-mode and a two-step selfetching adhesive with and without pre-etching of surface compared with two totaletching adhesive systems, two and three steps. Recently extracted human third molars were sectioned to obtain flat surfaces in enamel and dentin, which were ground with #600 SiC sandpaper to standardize the smear layer. These samples were randomly assigned into 6 groups: (SBU) Scotchbond Universal; (SBU-et) SBU pre-etched; (CSE), Clearfil SE Bond, (CSE-et) CSE pre-etched; (SBMP) Scotchbond Multi-Purpose, and (EX) Excite F. The groups total-etching and selfetching to be evaluated with pre-etching received the application of phosphoric acid for 15s in dentin and 30s in enamel. All adhesive systems were applied according to manufacturers' recommendations. Then, a block of composite resin (Filtek Supreme Plus) was constructed incrementally on each surface prepared for BS testing. For AI, the areas were filled with flowable resin (Filtek Flowable Restorative Z-350) forming a "sandwich" of enamel or dentin. After 24 hours, to review the BS, the specimens were sectioned into sticks with cross-sectional area of 0.8mm² and submitted to microtensile test at a speed of 1.0mm/min. The results were statistically analyzed by one-way ANOVA test and Fisher's PLSD (?=0.05) and fracture patterns were analyzed through Scanning Electron Microscopy (SEM). For analysis of AI, two samples from each group were embedded in epoxy resin, polished and observed through SEM. For enamel, the results of BS showed that SBU-et and CSE-et obtained the highest values, followed by SBMP groups, SBU and CSE with no differences among them. The EX group obtained the lowest values of all other groups. In the analysis of AI, and CSE-et and SBU-et groups showed sharp tag extensions of the adhesive penetrated in the demineralized enamel, similar to total-etching systems. As for dentin, BS results showed that acid etching significantly reduced the BS values of self-etching systems. The highest values were obtained by the SBU, CSE and SBMP with BS values statistically equivalent to each other. As in enamel, the adhesive system EX obtained the lowest values. SEM analysis showed that BS for pre-etched dentin with selfetching adhesive forms a thicker hybrid layer with resin tags formation, similar to total-etching adhesive systems. It can be concluded that on enamel, the preetching significantly increased BS for self-etching systems. However, these adhesive systems showed no statistical difference from conventional adhesive SBMP. And to dentin, pre-etching of sel-etching adhesives significantly reduced BS, however, SBU-et values were not significantly different from those obtained by the conventional adhesive system SBMP
Mestrado
Dentística
Mestra em Materiais Dentários
APA, Harvard, Vancouver, ISO, and other styles
9

Iost, Rodrigo Michelin. "Biocélula a combustível on-chip utilizando folhas individuais de grafeno." Universidade de São Paulo, 2016. http://www.teses.usp.br/teses/disponiveis/75/75134/tde-22092016-104129/.

Full text
Abstract:
A miniaturização de uma biocélula a combustível (BC) enzimática de glicose/O2 para aplicação em dispositivos bioeletrônicos implantáveis representa um grande desafio em eletroquímica moderna. Isso porque é preciso desenvolver bioeletrodos com alta atividade bioeletrocatalítica, com enzimas fortemente ligadas a superfície eletródica. Além disso, o próprio processo de micromanipulação é desafiador, uma vez que é desejável obter biocélulas miniaturizadas e com alta densidade de potência. Assim, propõe-se aqui o desenvolvimento de uma BC que atenda os requisitos supracitados. Para isso, desenvolveram-se bioânodos e biocátodos compostos por folhas de grafeno individuais modificadas com as enzimas glicose desidrogenase (GDh) e bilirrubina oxidase (BOx), respectivamente. Eletrodos de grafeno com área de 10-3 cm2 e espessura de 0,9 ± 0,2 nm foram utilizados em um microchip de Si/SiO2. Observou-se que o grafeno transferido para o microchip permanecia com contaminações de cobre, mesmo após a utilização dos métodos químicos tradicionais de remoção desse metal. A presença de cobre é decorrente do processo de fabricação do grafeno, neste caso, a deposição química em fase vapor (CVD). Para remover qualquer resíduo deste metal, submeteu-se o grafeno a um procedimento de remoção eletroquímica de cobre, denominada aqui como e-etching. Uma vez não observada qualquer corrente faradaica residual associada às impurezas, obtiveram-se os bioeletrodos com a GDh e a BOx. Para a imobilização enzimática, utilizou-se a ligação covalente via funcionalização com o ácido 4-aminobenzóico. As curvas de polarização de estado quase-estacionário obtidas com os bioeletrodos em tampão fosfato pH 7,0 revelaram correntes de onset para oxidação de glicose em -0,13 V e redução de oxigênio em 0,45 V. Por fim, os eletrodos foram utilizados em uma BC sem membrana, operando no microchip de Si/SiO2, em eletrólito tampão fosfato saturado com O2 e glicose 8,0 mmol L-1. A BC apresentou um potencial de circuito aberto em 0,55 V, com densidade de potência volumétrica igual a 1,7 W cm-3, o maior valor reportado até os dias de hoje para uma BC.
The miniaturization of a glucose/O2 enzymatic biofuel cell (BFC) for application in implantable bioelectronic devices is a challenge in electrochemistry. For this purpose, the necessity of bioelectrodes development with high biocatalytic activity such as enzymes strongly attached to electrode surfaces is a current trend. Moreover, the micromanipulation procedure itself is a challenge since the obtention of BFCs with high power density is desirable. Then, the present study shows the partial results obtained in the development of a glucose/O2 BFC with the characteristics exemplified. For the later, bioanodes and biocathodes were obtained with single graphene flakes modified with the enzymes glucose dehydrogenase (GDh) and bilirubin oxidase (BOx), respectively. Graphene flakes electrodes with area of about 10-3 cm2 and thickness of 0,9 ± 0,2 nm were used in a Si/SiO2 microchip. It was observed that transferred graphene to the microchip remained with copper/copper oxide contamination even after the use of conventional methodologies for the remotion of the metal from single graphene foils. The presence of the remaining copper is due to the fabrication process of graphene by chemical vapor deposition (CVD). For the remotion of remaining impurities from graphene, the electrochemical remotion of copper from graphene was carried out in acidic media by the so called e-etching procedure. Since no residual faradaic current was observed due to metal/metal oxide impurities in graphene electrodes, the bioelectrodes were obtained with the enzymes GDh and BOx. The covalent functionalisation of graphene with 4-aminobenzoic acid via diazonium coupling reaction was used for the enzymatic immobilization. The quasi-stationary polarization curves obtained with the bioelectrodes in phosphate buffer pH = 7,0 showed onset oxidation current for glucose at -0.13V and reduction of molecular oxygen starting at +0.45V. Finally, the bioelectrodes were used in a membraneless BFC operating in a Si/SiO2 microchip under saturated oxygen and glucose 8 mmol L-1 in the electrolyte media. The BFC showed an open circuit potential at 0.55V and volumetric power density of 1.7 W cm-3, the highest value reported for an enzymatic BFC so far.
APA, Harvard, Vancouver, ISO, and other styles
10

Hamaya, Pedro Yukio de Barros. "Paisagens flutuantes." Universidade de São Paulo, 2016. http://www.teses.usp.br/teses/disponiveis/27/27159/tde-22032017-104803/.

Full text
Abstract:
Este trabalho é o resultado de uma pesquisa envolvendo estudos, reflexões e experimentações poéticas que buscam problematizar a percepção visual sobre a representação bidimensional e sobre a realidade cotidiana - o conjunto aqui apresentado reúne textos reflexivos, imagens produzidas (desenhos, pinturas e gravuras) e anotações sobre o processo. Num primeiro momento, ele centra na exploração das possibilidades em torno da construção de um efeito flutuante na visualidade imagética, tentando tensionar os modos de apreender a representação bidimensional. Num segundo momento, ele acrescenta a seu quadro de reflexões uma indagação sobre a experiência visual na realidade cotidiana, mais especificamente no deslocamento diário pela cidade de São Paulo, e tenta abordar a paisagem urbana pela perspectiva da representação flutuante. Como um meio de aprofundar certas questões que permeiam o processo poético, são apresentadas três reflexões independentes sobre temas distintos: 1. a espacialidade na tradição pictórica sino-japonesa do Suibokuga; 2. a relação entre cor e linguagem na pintura de Mark Rothko; e 3. possibilidades de se orientar visualmente pela cidade de São Paulo a partir da referência a algumas características básicas compreendidas nas construções espaciais da cultura japonesa. Esses textos tem como objetivo complementar as imagens produzidas, tentando mapear o conjunto de inquietações que impulsionaram o seu desenvolvimento.
The present work is the result of a process involving studies, reflections and poetic experiments which seek to approach the visual perception of the two-dimensional representation and the everyday reality - the contents presented here gather together reflexive texts, produced images (drawings, paintings and engravings) and notes on the process. At first, the process focused on the exploration of possibilities surrounding the construction of a floating effect on visual imagery, attempting to generate discomfort and doubts on the ways of visually apprehending the two-dimensional representation. Secondly, it adds to its set of reflections an inquiry about the visual experience in everyday reality, specially in the daily routine in the city of São Paulo, and attempts to approach the urban landscape from the perspective of the floating representation. As a mean to develop certain issues that permeate the poetic process, three independent reflexive texts about distinctive themes are here presented: 1. one about spatiality in Sino-Japanese pictorial tradition of Suibokuga; 2. one about the relationship between color and language in Mark Rothko\'s paintings; and 3. one about possibilities for one to visually guide himself through the city of São Paulo from the point of view of some basic features inherent to spatial constructions of Japanese culture. These texts have the objective to supplement the images produced along the poetic process, in an attempt of mapping the set of concerns which drove its development.
APA, Harvard, Vancouver, ISO, and other styles
11

Santos, Tôni Rabello dos, and Tôni Rabello dos Santos. "Percepções de um eletrogravador: experiências poéticas com a corrosão." Universidade Federal de Pelotas, 2014. http://repositorio.ufpel.edu.br/handle/ri/2769.

Full text
Abstract:
Submitted by Aline Batista (alinehb.ufpel@gmail.com) on 2016-03-04T13:33:52Z No. of bitstreams: 2 Percepções de um eletrogravador.pdf: 13125292 bytes, checksum: e3ddba1b8b53b0891f534de04e4764ae (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Approved for entry into archive by Aline Batista (alinehb.ufpel@gmail.com) on 2016-03-04T14:24:00Z (GMT) No. of bitstreams: 2 Percepções de um eletrogravador.pdf: 13125292 bytes, checksum: e3ddba1b8b53b0891f534de04e4764ae (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Approved for entry into archive by Aline Batista (alinehb.ufpel@gmail.com) on 2016-03-04T14:27:37Z (GMT) No. of bitstreams: 2 Percepções de um eletrogravador.pdf: 13125292 bytes, checksum: e3ddba1b8b53b0891f534de04e4764ae (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Made available in DSpace on 2016-03-04T14:30:27Z (GMT). No. of bitstreams: 2 Percepções de um eletrogravador.pdf: 13125292 bytes, checksum: e3ddba1b8b53b0891f534de04e4764ae (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2014-05-28
Fundação de Amparo à Pesquisa do Estado do Rio Grande do Sul - FAPERGS
Esta dissertação aborda questões referentes ao meu processo de criação, e assuntos que dialogam com as produções realizadas no mestrado em Artes Visuais da UFPel. As produções que compõem este trabalho tecem sutis relações entre o universo da gravura, as impressões e incisões no cotidiano. A dissertação é organizada de modo a sistematizar uma poética sobre o ato de gravar, que se desenvolveu paralelo as práticas com procedimentos eletrolíticos na gravura em metal, o que apresento são percepções de um eletrogravador. A prática é o ponto de partida dessa investigação que visa expor um olhar que excede o espaço do atelier, explorando questões e acontecimentos que me atravessaram durante os dois anos que compreende o mestrado. É reconhecido, neste texto, a importância do experimento para alcançar uma experiência intensa na produção artística. Correr riscos, explorar o acaso e permanecer atento sobre as coisas que me rodeiam são algumas das estratégias utilizadas durante essa pesquisa. Meus objetos de estudos correspondem a dez trabalhos processuais, são eles: Captador de Resíduos; Pequenos Naufrágios; Céu; Mapas Poéticos do Interior do Cubo Vermelho; Em Três Tempos; Paisagem Corroída; Contendo Sopro; Receptor de memórias; Projeto Matriz Compartilhada e Conexão Céu e Terra, os mesmos são dispositivos artísticos, projetos artísticos e/ou ações artísticas. No texto, os trabalhos aparecem em um discurso “rio” que percebe cada um deles em seu estado de formação, em que uma ação se une a outra, num desdobrar dos pensamentos que os formaram. Pretendo, em meio às palavras e imagens do processo de criação, apresentar as transformações deste, que pode ser interpretado como uma “fase de transição” que parte do atelier de gravura para o espaço. Nesse sentido, o que apresento são atos de corrosões que dividem em três fases, cada uma delas contém registros de ações realizadas no atelier de gravura, ações frente à paisagem e acontecimentos que me atravessam no cotidiano. Portanto, os conceitos operacionais desta investigação poética são: extrair, deslocar e fixar; estas ações sustentam as discussões sobre os processos alquímicos na produção artística e nas reflexões sobre a corrosão e o ato de gravar. Em dialogo com a minha produção e pesquisa sobre a corrosão, abordo determinados trabalhos e reflexões de artistas como: Marco Buti; Robert Smithson; Daniel Senise; Elida Tessler, Victor Gripp, Hans Haacke, Richard Long, Cinthia Marcelle, Paulo Damé, Carlos Filho e os teóricos Gaston Bachelard; Gilles Deleuze, Virgínia Kastrup, Michel de Certau, Francesco Careri, Georges Didi-Huberman, entre outros. Em fim, proponho uma reflexão sobre a corrosão como uma ação que produz gravura.
This paper intends to address topics that have been relevant to my creation process, along with other issues that influenced the work that i've been performing during my master's degree in Visual Arts UFPEL. The work i present here make subtle relations between the engraving process and the marks we see throughout our daily lives. The paper is organized in a way so that it makes understandable that the poetic that arises from the engraving process is parallel to the electrolytic procedures found in metal engraving. Here i present the perceptions of an engraver. The practice is the starting point of this investigation. It's aim is to focus on the act of seeing, implying that it goes beyond the atelier walls, exploring questions and events that trespassed my mind during the two year duration of my master's degree. I acknowledge during the text the vital importance of experimenting so you can reach a full comprehension of your artistic production. Take chances, exploit events that happen by chance and remain prepared to analyse your surroundings. Those are some of the strategies that have been used during this research. My study object is composed of ten processual works, those are: Captador de Resíduos; Pequenos Naufrágios; Céu; Mapas Poéticos do Interior do Cubo Vermelho; Em Três Tempos; Paisagem Corroída; Contendo Sopro; Receptor de memórias; Projeto Matriz Compartilhada and Conexão Céu e Terra. Some of those focus on the idea of being artistic devices; artistic projects and/or artistic actions. During the text, the interpretation of those objects happens in a “river” like manner, perceiving each and every one of them in their conception, the moment in time where those pieces connect with each other through a fluid and continuous line of thought. I intend to present to you, through images and words, the moment where my artwork changes its shape, what can be understood as a “transition process” in which it leaves the atelier and invades the space. In this manner, i present acts of corrosion that divide in three phases. Each one of them contain not only records of actions that took place in the metal etching atelier but also actions made to interact with the landscape and events thar affected me in my daily life. After a while photography became a part of my work process, eventually becoming as important as engraving. The operational concepts of this poetic investigation are: to extract, to displace and to firm. Those three actions support the discussions that revolve around the alchemical processes that are needed in those artistic productions and reflections about the corrosion and etching action. To be able to advance the current researches i take as reference artists such as: Marco Buti; Robert Smithson; Daniel Senise; Elidada Tessler, Victor Gripp, Hans Haacke, Richard Long, Cinthia Marcelle, Paulo Damé, Carlos Filho and theorics such as: Gaston Bachelard; Gilles Deleuze, Virgínia Kastrup, Michel de Certau, Francesco Careri, Georges Didi-Huberman, among others.
APA, Harvard, Vancouver, ISO, and other styles
12

Bose, Abhijit Frank. "Diagnostics and control of plasma etching reactors for semiconductor manufacturing /." [S.l.] : [s.n.], 1995. http://e-collection.ethbib.ethz.ch/show?type=diss&nr=11224.

Full text
APA, Harvard, Vancouver, ISO, and other styles
13

Aronis, Jacqueline. "Matéria gráfica: idéia e imagem." Universidade de São Paulo, 2009. http://www.teses.usp.br/teses/disponiveis/27/27159/tde-13072009-185747/.

Full text
Abstract:
Gravura e desenho como matéria gráfica; como registros de ideias e anotações decorrentes de uma memória constitutiva.Sonhos e projetos como proposição e realização de um trabalho.
Printmaking and drawing as graphic matter.Ideas and notes arising from a constitutive memory.Dreams and projects as proposal and materialization of a work of art.
APA, Harvard, Vancouver, ISO, and other styles
14

PEREIRA, MARCO A. S. "Emprego dos policarbonatos makrofol-de e CR-30 em radiografia com neutrons." reponame:Repositório Institucional do IPEN, 2000. http://repositorio.ipen.br:8080/xmlui/handle/123456789/9293.

Full text
Abstract:
Made available in DSpace on 2014-10-09T12:25:48Z (GMT). No. of bitstreams: 0
Made available in DSpace on 2014-10-09T14:03:33Z (GMT). No. of bitstreams: 1 11313.pdf: 4364467 bytes, checksum: 80dca67e716c2de36cf87cbbab397c48 (MD5)
Dissertacao (Mestrado)
IPEN/D
Intituto de Pesquisas Energeticas e Nucleares, IPEN/CNEN-SP
APA, Harvard, Vancouver, ISO, and other styles
15

Abreu, Paulo Humaitá de. "Resistência à corrosão de amálgamas e de liga à base de gálio, sem e com adesivos, através do método de perda de peso e análise da rugosidade de superfície." Universidade de São Paulo, 2002. http://www.teses.usp.br/teses/disponiveis/25/25131/tde-23082011-093619/.

Full text
Abstract:
Avaliou-se a resistência à corrosão pelos testes de perda de peso em imersão alternada (solução-ar) e as conseqüentes alterações produzidas nas superfícies dos três materiais restauradores (os amálgamas Dispersalloy e Tytin Plus, ambos de alto conteúdo de cobre, respectivamente do tipo fase dispersa e do tipo partícula única, assim como a liga à base de gálio Galloy), não ou associados a dois sistemas adesivos (All-Bond 2 e PAAMA-2), observadas através da medição da rugosidade de superfície. Confeccionou-se dez corpos-de-prova, para cada condição específica, a partir de uma matriz metálica de aço inoxidável contendo cinco cavidades cilíndricas, com 10,7 mm de diâmetro por 3,0 mm de altura cada uma. Após o polimento, como é feito no caso de análises metalográficas, os espécimes foram pesados e levados ao rugosímetro para realizar as medições imediatamente. Estes foram submetidos à imersão alternada, na solução de sulfeto de sódio a 5 %, por um período de 24 horas e novamente foi realizada a pesagem e obtidos os valores de perda de peso. Depois da pesagem, os corpos-de-prova foram levados novamente ao rugosímetro para obtenção dos valores médios de rugosidade de superfície. Os resultados foram registrados e submetidos à análise de variância, a dois critérios, e ao teste de contrastes de Tukey-Kramer. Dos resultados obtidos, conclui-se que todos os espécimes perderam peso e tiveram sua rugosidade de superfície aumentada após a imersão em solução corrosiva; a liga Galloy mostrou valores maiores, tanto no método de perda de peso como no de rugosidade de superfície, quando comparada aos dois amálgamas; a liga Tytin Plus alcançou os melhores resultados; houve diferença estatisticamente significante entre os materiais restauradores, mas não entre os sistemas adesivos utilizados, mostrando comportamentos diferentes dependendo da combinação desses fatores.
The resistance to the corrosion was evaluated through weight loss to an alternated immersion (solution-air) and its consequent changes on the surface of three restoring materials (them amalgams Dispersalloy and Tytin Plus, both with high copper content, respectively dispersion phase and unique particle, as well as the alloy gallium base Galloy), associated or not to two adhesive systems (All-Bond 2 and PAAMA-2), observed by measuring the surface roughness. Ten bodies-of-test were made, for each specific condition, in a metallic matrix os stainlesss steel with five cilindrical cavities, measuring 10,7 mm in diameter and 3,0 mm thickness each one. After polishing, as in the metalographic anal ysis, the specimens were weighed and submitted to the roughness measurer to measuring inicial. These were submitted to an alternated immersion in 5 % sodium sulfide solution, for 24 hours and then the second weighting was performed and obtained the average values of weight loss. A second measure of the surface roughness was then performed. The results were registered and submitted to the variance analysis, to two approaches, and to the test of contrasts of Tukey-Kramer. From the obtained results, it was concluded that all specimens lost weight and there was an increasing roughness surface after immersion in corrosive solution; Galloy showed higher values, both weight loss test and the rougness surface, compared to two amalgams; the alloy Tytin Plus obtained better results; there was significant statistical difference among the restoring materials, but not among adhesive systems, showing different behaviors according to arrangement of these factors.
APA, Harvard, Vancouver, ISO, and other styles
16

Jakas, Algirdas. "(Ne)išpildytos vietos." Master's thesis, Lithuanian Academic Libraries Network (LABT), 2014. http://vddb.library.lt/obj/LT-eLABa-0001:E.02~2014~D_20140703_160620-39400.

Full text
Abstract:
Raižau nebaigtus objektus. Pasirinkau Kaliningrade stovinį "Dom Sovietov", jam draugėn atsirado buvusiame Leningrade esantys "Dom Sovietov" (Sovietų namai). Juos jungia ne tik toks pat pavadinimas ,bet ir tai ,kad jie niekada nebuvo iki galo pabaigti - prie pirmojo pastato Kaliningrade darbai sustojo baigus statyti 90 proc. objekto, antrasis ,nors ir baigtas konstrukcine - architektūrine prasme ,niekada nebuvo naudotas pagal paskirtį, kuriai buvo statomas... Taip išsirikiavo vienu ar kitu būdu neužbaigti 7 pastatai - objektai. Vienu atveju tai tik projektas popieriaus lape (administracinis pastatas, planuotas statyti dabartinėje Lukiškių aikštėje) , kitu - vienintelis išlikęs objektas - nuoroda į nepastatytus grandiozinius "Sovietų rūmus". Bandau būti tuo "inžinieriumi", kuris mėgina juos užbaigti raižydamas. Suvienodinu ir nefragmentuoju, sieju juos į visumą ,nesvarbu iš kokio laikmečio šie objektai yra. Aiškinuosi, kokia tų objektų padėtis dabar, žlugus sistemai, ar galima juos atsieti nuo aplinkos ir iš naujo permąstyti ? Prie kiekvieno pastato palieku trumpą jo "biografiją". Taip pat cikle spekuliuoju savo senelio, inžinieriaus, "garbės lenta" - ten įrašau savo vardo raidę , taip ją (lentą) pasisavinu ir jungiu su raižiniais.
Print cycle of unfinished soviet era buildings - objects. As example there could be "House of soviets" in Kaliningrad by means of construction unfinished building. In pair to him stands "House of Soviets" in St. Petersburg, in this case building unfinished mentaly. I'm trying to be that engineer who finishes these objects on paper.
APA, Harvard, Vancouver, ISO, and other styles
17

Gonçalves, Sérgio Eduardo de Paiva. "Dentina humana e bovina: estudo comparativo das propriedades físicas e características da hibridização de sistemas adesivos convencionais ou grander modificados: análise em mev /." São José dos Campos : [s.n.], 2005. http://hdl.handle.net/11449/116111.

Full text
Abstract:
Resumo: A adesão longitudinal continua a representar um dos maiores desafios da Odontologia moderna. Uma nova proposta para o estabelecimento do equilíbrio da adesão aos tecidos dentários surge, baseada na observação dos resultados obtidos com a tecnologia Grander para revitalização da água. Objetiva-se com o estudo verificar a influência dessa tecnologia nas propriedades físicas de dois sistemas adesivos (convencional e autocondicionante) à partir da medição da tensão superficial e do ângulo de contato; e avaliar a formação e a qualidade da camada híbrida em dentina humana e bovina. A tensão superficial de quatro diferentes líquidos (água, Single Bond- 3M, Primer do Clearfil SE Bond -Kuraray, e Bond do Clearfil SE-Kuraray), foi medida antes e após a modificação pelo procedimento Grander em aparelho goniômetro (Ramé-hart). O ângulo de contato com três substratos distintos (placa de titânio, dentina humana e dentina bovina), foi medido para os quatro líquidos também antes e após a modificação pelo procedimento Grander, também em goniômetro. A formação e qualidade da camada híbrida, foi avaliada em MEV, a partir da confecção de corpos de prova dos substratos humano e bovino, devidamente embutidos, preparados em lixas de variada granulação até a exposição de dentina, submetidos ao procedimento adesivo (SB ou CSEB) normal ou grander modificado, recebendo ao final dupla camada de resina composta Z250-3M, fotopolimerizada por 40s. Após armazenamento em estufa bacteriológica por 24h, os procedimentos para análise ao MEV foram realizados (fixação, desidratação, secagem e metalização). A estatística de Análise de Variância ANOVA e Teste de Tukey 5% revelou que: houve redução estatisticamente significante da tensão superficial para todos os líquidos Grander modificados; houve redução estatisticamente... (Resumo completo, clicar acesso eletrônico abaixo)
Abstract: A long-lasting adhesion is still one of the biggest challenges of the modern Dentistry. A new approach to reaching the equilibrium of the adhesion to the dental tissues emerges based on the observation of the results obtained with the Grander Technology for revitalizing water. The aim of this study was to verify the influence of this technology on the physical properties of two adhesive systems (conventional and self-etching) through the measurement of the surface tension and of the contact angle and through the evaluation of the formed hybrid layer in human and bovine dentin. The surface tension of four different liquids (water, Single Bond - 3M, Clearfil SE primer - Kuraray and Clearfil SE bond - Kuraray) was measured before and after submitting these liquids to the Grander modifying unit, with the aid of a goniometer (Ramé-hart). The measurement of the contact angle of the liquids followed the same procedure using three distinct surfaces: titanium plate, human dentin and bovine dentin. The hybrid layer formed for both: non-modified and Grander modified adhesive systems, was evaluated in SEM. For this purpose human and bovine dentin samples were prepared. The teeth were fixed in acrylic resin and the dentin surfaces exposed and finished with various grit polishing paper discs. These dentin surfaces were then treated with the adhesive procedures (normal and Grander modified), before the placement of a double composite resin layer (Z250- 3M). After storage at 37oC for 24h, the SEM analysis were conducted. The data were submitted to ANOVA and Turkeys test 5%. The results showed statistically significant reduction for the surface tension of all liquids modified by the Grander technology, as well as for the contact angle in the human dentin. Statistically significant were also the results showing a thicker hybrid layer formation with the two adhesive systems when modified by the Grander... (Complete abstract click electronic access below)
APA, Harvard, Vancouver, ISO, and other styles
18

Besseler, Edmilson. "Construção e caracterização de um reator indutivo : ICP para corrosão de materiais." [s.n.], 2008. http://repositorio.unicamp.br/jspui/handle/REPOSIP/259745.

Full text
Abstract:
Orientadores: Peter Jurgen Tatsch, Stanislav A. Moshkalyov
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação
Made available in DSpace on 2018-08-11T19:17:46Z (GMT). No. of bitstreams: 1 Besseler_Edmilson_M.pdf: 3143419 bytes, checksum: 2715af82a31f1728537a14b1764455a6 (MD5) Previous issue date: 2008
Resumo: Esta dissertação apresenta as etapas do trabalho de construção de um Reator ICP destinado a processos de micro fabricação, mais precisamente, destinado a corrosões profundas de Silício a taxas de corrosões elevadas. O modelamento e as caracterizações do reator ICP foram feitas através de um protótipo e depois aplicadas a um equipamento da LAM Research que funcionava em modo RIE. Este foi adaptado para trabalhar em modo ICP, de acordo com os parâmetros obtidos no protótipo. Para isso, foi necessário a instalação do Equipamento e fornecer toda a infra-estrutura que este necessitava para seu funcionamento. Foram desenvolvidos casadores de impedância para ligação dos geradores de RF à bobina do ICP e do eletrodo de polarização da amostra, controladores de fluxo de gases, chaveadores manuais para válvulas pneumáticas, sistemas de refrigeração e tubulação de vácuo. O plasma foi caracterizado e alguns processos foram realizados com o intuído de mostrar o comportamento com relação à variação de parâmetros como pressão, potência, polarização da amostra, fluxo de gases, tempo de processo, área da lâmina exposta ao plasma e também o comportamento de diferentes tipos de máscaras. O Equipamento também foi preparado para que seja possível a comutação de gases, que futuramente será automática, de modo que se possa realizar corrosões e polimerizações consecutivas, como ocorre em processos Bosch.
Abstract: This dissertation shows the steps to building an ICP Reactor dedicated to micro fabrication process, further to deep etching of Silicon on high rates. The modeling and characterization of ICP Reactor has been done in a prototype and after applied on an RIE equipment from LAM Research, that was adapted to work in ICP mode like the prototype. To do it was necessary equipment installation and give it the infra structure needed to it works. A network matching was developed to connect the RF generator to ICP coil and to the electrode of wafer polarization, such as gas flow controllers, manual switches for pneumatic valves, cooling systems and vacuum pipes. The plasma was characterized and some processes has been realized in order to show the trends against some parameters variation as pressure, power, sample polarization (bias), gas flow, process time, wafer area exposed to the plasma and also the behavior of different kind of masks. The equipment is ready to switch some gases, which will be automatic in the future, to corrosion and polymerization consecutive process as at a Bosch process.
Mestrado
Eletrônica, Microeletrônica e Optoeletrônica
Mestre em Engenharia Elétrica
APA, Harvard, Vancouver, ISO, and other styles
19

Cardenas, Andrés Felipe Millán. "EFEITO DE DIFERENTES pHs E TEMPOS DE APLICAÇÃO DO ÁCIDO METAFOSFÓRICO 40% NAS PROPRIEDADES ADESIVAS EM ESMALTE E DENTINA." UNIVERSIDADE ESTADUAL DE PONTA GROSSA, 2016. http://tede2.uepg.br/jspui/handle/prefix/1707.

Full text
Abstract:
Made available in DSpace on 2017-07-24T19:22:00Z (GMT). No. of bitstreams: 1 Andres Felipe M Cardenas.pdf: 5280325 bytes, checksum: 04a1911a6a06b35dcfc2a254330c8113 (MD5) Previous issue date: 2016-05-25
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
This study evaluated the effect of application the different pHs (0.5, 1 and 2) of meta-phosphoric acid 40% (MPA) with ortho-phosphoric acid 37% (OPA) in different application times with three laboratory studies in vitro. For all experiments, the teeth were distributed into 12 experimental conditions according to the combination of independent variables: acid [37% orthophosphoric acid (OPA), 40% metaphosphoric acid (MPA) pH - 0.5, 1 and 2] and application time [7, 15 and 30 seconds]. For experiment 1, the acids were applied on 72 human molars for microtensile bond strength (μTBS), and nanoleakage (NL). After acid conditioning the adhesive system was applied (Ambar) and restoration in composite resin was performed. Then, the teeth were sectioned to obtain specimens and tested immediately. The Etching Pattern (PC) was evaluated after acid application in dentin. For experiment 2, 93 human molars were used. After acid application in dentin, the adhesive system was applied and composite resin restoration was made. They were then sectioned, half sticks were tested immediately and the other half after 6 months of storage in water for μTBS and NL analysis. The analysis of chemical composition was performed by micro-Raman spectrometry. For experiment 3, 60 human molars were distributed according to the similar independent variables as the experiment 1 and 2. The enamel surfaces were stored in water (37 °C / 24 h) and tested for (μSBS). The PC and qualitative analysis composition of chemical enamel by micro-Raman test was evaluated. For the experiment 1 and 3, acid vs time of application the μTBS and NL data were submitted to 2-way ANOVA and Tukey's test (α = 0.05). For the experiment 2, acid vs application time vs storage time the μTBS data and NL were submitted to 3-way ANOVA and Tukey's test (α = 0.05). For experiment 1, MPA pH 0.5 showed μTBS similar to OPA, independent of the application time (p> 0.05) and statistically higher NL was observed for OPA compared with MPA (p <0, 03). For experiment 2, a significant decrease μTBS value was observed only OPA after 6 months (p = 0.001) and higher values of NL were found when compared to MPA (p = 0.003). For the experiment 3, OPA and MPA pH 0.5 produced statistically higher μSBS when compared to MPA pH 1 and 2 independent of the application times (p <0.001). The MPA acid is an alternative agent for the simultaneous conditioning of enamel and dentin, increasing the μTBS, reducing the NL immediate and after 6 months of storage when compared to the conventional ortho-phosphoric acid. The sum of the properties evaluated, MPA pH 0.5 showed high μSBS, showing be promissory.
O objetivo desse trabalho foi avaliar o efeito de diferentes pHs (0,5, 1 e 2) do ácido metafosfórico 40% (AMF) com o ácido ortofosfórico 37% (AOF) sob diferentes tempos de aplicação por meio de três estudos laboratoriais in vitro. Em cada estudo, os dentes foram distribuídos aleatoriamente em 12 condições de acordo com a combinação das variáveis independentes: Ácido [ácido ortofosfórico a 37% (AOF), ácido metafosfórico a 40% (AMF) pH - 0,5, 1 e 2] e tempos de aplicação [7, 15 e 30 s]. Para o experimento 1, os ácidos foram utilizadas e aplicados sobre 72 molares para resistência de união (RU) e nanoinfiltração (NI). Após condicionamento ácido aplicou-se o sistema adesivo (Ambar) e realizou-se a restauração em resina composta (Opallis). Depois de 24 h foram seccionados e testados. O padrão de condicionamento (PC) foi avaliado após aplicação dos ácidos em dentina. Para o experimento 2, foram utilizados 93 molares, após aplicação dos ácidos em dentina, aplicou-se o sistema adesivo e a restauração em resina composta. Logo após, foram seccionados e metade dos palitos foram testados imediatamente e a outra metade após 6 meses de armazenamento em água para análise da RU e NI. A análise da composição química foi realizada por espectroscopia micro-Raman. Para o experimento 3, 60 molares foram utilizados e distribuídos em função das variáveis já citadas. As superfícies de esmaltes foram armazenadas em água (37 °C / 24 h) e testadas para resistência de união no esmalte por microcisalhamento. O PC e análise de composição da química qualitativa do esmalte por teste micro-Raman foram avaliados. Para o experimento 1 e 3, ácido vs tempo de aplicação os dados de RU e NI foram submetidos a ANOVA 2 fatores e teste de Tukey (α = 0,05). Para o experimento 2, ácido vs tempos de aplicação vs tempo de armazenamento os dados de RU e NI foram submetidos a ANOVA 3 fatores e teste de Tukey (α = 0,05). Para o experimento 1, o AMF pH 0,5 mostrou RU significativamente semelhante ao AOF, independentemente do tempo de aplicação (p>0,05) e uma NI estatisticamente mais elevada foi observada para AOF em comparação com AMF, (p<0,03). Para o experimento 2, diminuições significativas nos valores de RU foram observados somente para AOF após 6 meses (p = 0,001) e valores de NI mais elevados foram encontrados quando comparado com AMF (p = 0,003). Para o experimento 3, o AOF e AMF pH 0,5 produziram valores RU estatisticamente mais elevados, quando comparados com AMF pH 1 e 2 independentemente dos tempos de aplicação (p<0,001). O AMF é um ácido que pode ser utilizado simultaneamente em esmalte e dentina, demonstrando uma alta RU, diminuição da nanoinfiltração imediata e após 6 meses de armazenamento quando comparado com o AOF. No somatório das propriedades avaliadas, o pH 0,5 apresentou alta RU em esmalte em relação ao AOF, mostrando-se promissor.
APA, Harvard, Vancouver, ISO, and other styles
20

Nunez, Eroles Marc. "Nanogravure et caractérisation structurale et électronique de rubans de graphène cristallins." Thesis, Toulouse 3, 2015. http://www.theses.fr/2015TOU30201/document.

Full text
Abstract:
Les principaux objectifs de cette thèse sont la fabrication et la caractérisation structurale à haute résolution de nanorubans de graphène à bords atomiquement lisses ainsi que leur intégration dans des composants et l'étude du transport électronique. En premier lieu, nous montrons que des nanorubans de graphène cristallins de largeur inférieure à 100 nm et avec des qualités structurales supérieures l'état de l'art peuvent être découpé par un faisceau électronique focalisé d'énergie modérée en présence d'oxygène. Les caractéristiques des rubans obtenus sont également supérieures à l'approche précédente utilisant la vapeur d'eau. Dans un deuxième temps, la structure des nanorubans est caractérisée jusqu'à l'échelle atomique par microscopie électronique en transmission corrigée des aberrations sphériques. Nous montrons que la cristallinité des nanorubans, tant en leur centre que le long des bords de découpe, est préservée. Les performances de notre approche atteignent l'état de l'art et sa reproductibilité permet de fabriquer des rubans longs de plusieurs centaines de nanomètres mais de largeur aussi fine que 16 nm. Ensuite, nous avons transposé la découpe de nanoruban suspendus à une configuration partiellement suspendue sur substrat SiO2/Si permettant de les intégrer dans des composants adaptés aux mesures de transport électronique à basse température et sous champ magnétique. Le transport électronique dans les rubans contactés de 60 x 300 nm présente un gap et des oscillations en balayage de grille arrière qui sont en accord avec un mécanisme de blocage de Coulomb dans un domaine de taille de l'ordre de la taille du ruban. Si ces résultats montrent la persistance de barrières tunnel, ses bords semblent de qualité suffisante pour ne pas induire de confinement supplémentaire. Au-delà des composants mésoscopiques, notre méthode de fabrication des rubans par gravure électronique sous oxygène ouvre des perspectives dans deux domaines en émergence. Elle est compatible avec l'ultravide et parfaitement adaptée au développement d'une technologie atomique à base de graphène. Une caractérisation de la contamination du graphène ainsi qu'une caractérisation électrique de dispositifs de graphène qui a été fait par microscopie à effet tunnel multisonde en ultra vide. Enfin, les rubans de graphène que nous produisons ont les dimensions et qualités structurales requises pour observer un comportement plasmonique du graphène dans le visible et ainsi interagir avec des structures plasmoniques métalliques. Ce couplage a été examiné en étudiant le signal Raman du graphène au voisinage de colloïdes d'or
The main objectives of this thesis are the fabrication and high-resolution structural characterisation of graphene nanoribbons with atomically smooth edges as well as their device integration and electronic transport study. In first place, we show that crystalline graphene nanoribbons with width under 100 nm and structural properties better than the state of the art can be patterned by a focused electron beam in presence of oxygen. The structural characteristics of the ribbons are also better than the old process using water vapour. Secondly, nanoribbons structure is characterized down to the atomic scale by spherical aberration corrected transmission electron microscopy. We show that the nanoribbons crystallinity, of the centre as well as along the cut edges, is preserved. The performance of our process reaches the state of the art and its reproducibility allows to produce ribbons with length of hundreds of nanometer but as narrow as 16 nm. After that, we have transposed the suspended nanoribbon etching to a partially suspended configuration on a SiO2/Si substrate allowing the integration in devices suitable for electronic transport measurements at low temperature and under magnetic field. The electronic transport in contacted ribbons of 60x300 nm shows a gap and oscillations on backgate scanning measurements that are in agreement with a Coulomb blockade mechanism with dot sizes in the range of the ribbon surface. Even though those results show the persistence of tunnel barriers, the edges quality look good enough to avoid additional confinement. Other than mesoscopic devices, our ribbon fabrication process by electronic beam under oxygen atmosphere opens perspectives in two emergent fields. The process is ultra high vacuum compatible and perfectly adapted to the development of an atomic graphene based technology. A characterisation of contaminants of graphene samples as well as electrical characterisation of graphene devices has been performed in a multiprobe scanning tunnelling microscope in ultra high vacuum. Finally, our graphene nanoribbons have the right dimensions and structural qualities required for the observation of plasmonic behaviour of graphene in visible light and so interact with metallic plasmonic structures. This coupling has been analysed by studying the Raman signal of graphene at the close environment of gold colloids
APA, Harvard, Vancouver, ISO, and other styles
21

Bustamante, Rina Huamanrayme. "Fabricação de nanoestruturas de alumina anódica porosa e suas aplicações na síntese de nanomateriais." Universidade de São Paulo, 2012. http://www.teses.usp.br/teses/disponiveis/3/3140/tde-13062013-162134/.

Full text
Abstract:
Nanoestructuras de alumina anódica porosa (AAP) têm sido tradicionalmente fabricadas por duas etapas de anodização a temperaturas relativamente baixas (de 0 até 5°C), e usadas como máscaras ideais para formação de vários materiais nanoestruturados. Neste sentido, o objetivo do trabalho foi estudar sistematicamente a formação e a fabricação de nanoestruturas de AAP autoorganizadas por uma só etapa de anodização e posterior aplicação na síntese de nanopartículas e nanofios metálicos. As nanoestruturas auto-organizadas de AAP foram obtidas por apenas uma etapa de anodização em ácido oxálico (H2C2O4) a temperatura ambiente; diferentemente dos processos convencionais onde são utilizados duas ou mais etapas de anodização. As características estruturais dos filmes de AAP foram moduladas através do controle dos parâmetros da concentração da solução, temperatura e potencial de polarização. O procedimento principal, para a obtenção de AAP auto-organizadas apenas por uma etapa de anodização, foi o pós-processamento de abertura dos poros através de um processo de corrosão química. Os resultados obtidos neste trabalho mostraram que o diâmetro médio dos poros apresentou uma dependência linear com a temperatura, potencial e tempo de corrosão química e foi constante em relação à concentração da solução eletrolítica. No entanto, a análise estrutural via microscopia eletrônica de varredura (MEV), mostrou que a circularidade e a ordem dos nanoporos sobre a superfície anodizada melhoraram com o aumento da concentração do eletrólito. A estrutura de AAP com um arranjo hexagonal de poros regularmente distribuídos foi obtida quando a anodização foi realizada em 0,3M de H2C2O4, a 45V e 20°C de temperatura seguido de uma corrosão química a temperatura de 17°C por 102 minutos. Adicionalmente foram obtidos nanopartículas e nanofios metálicos utilizando-se as nanoestruturas de AAP como moldes. Como os filmes de AAP são isolantes a obtenção das nanopartículas e nanofios foi realizado através de um processo de eletrodeposição de corrente alternada (CA). Os resultados deste trabalho mostraram que nanoestruturas de AAP autoorganizadas podem ser fabricadas por uma etapa de anodização controlando o tempo de corrosão química. Os resultados apresentados neste trabalho mostram-se vantajosos em relação aos reportados na literatura, já que normalmente as nanoestruturas de AAP são obtidas mediante processos de anodização em duas etapas e tempos longos de anodização.
Nanostructures of porous anodic alumina (PAA) have been traditionally manufactured by two steps anodization at relatively low temperatures (0 to 5°C) and used as templates suitable for the formation of various nanostructured materials. In this sense, the goal of this work was the fabrication of self-organized porous Anodic alumina nanostructures (AAP) by a one anodization step and subsequent application in the synthesis of metal nanowires and nanoparticles. The self-organized nanostructures of PAA were obtained by just one anodization step in oxalic acid (H2C2O4) at ambient temperature unlike to conventional processes where they are used two or more anodization steps. The structural characteristics of PAA films were modulated through control of the solution concentration, temperature and potential of polarization. The key procedure to obtain the periodic organized PAA by only one step anodization was the post-processing of pore opening through a process of corrosion chemistry. The results of this work showed that the average diameter of pores presented a linear dependence with temperature, time of chemical corrosion, polarization potential and it was constant relative to the concentration of the electrolyte solution. However, the structural analysis via scanning electron microscopy (SEM) showed that the roundness and the order of nanoporos over the anodized surface improved with the electrolyte concentration increasing. The PAA structure with a hexagonal arrangement of pores was obtained when the anodization was held in 0.3 M of H2C2O4, 45V, and 20°C of temperature followed by a chemical corrosion at 17°C of temperature for 102 minutes. Additionally it was obtained nano particles and nano metal wires using the PAA structures as molds. Since the PAA films are insulating, the nanoparticles and nanowire were obtained through an electrodeposition process using alternating current. The results of this work have shown that self-organized PAA nanostructures can be fabricated by one anodization step controlling the time of chemical etching process. The results presented in this work are advantageous in relation to reported in the literature, since normally the structures of PAA are obtained by two step anodization and for long anodization time.
APA, Harvard, Vancouver, ISO, and other styles
22

Caiado, Ana Carolina Rocha Lima. "Resistencia de união e caracterização morfologica da dentina coronaria e radicular tratada com sistemas adesivos." [s.n.], 2006. http://repositorio.unicamp.br/jspui/handle/REPOSIP/288182.

Full text
Abstract:
Orientador: Mario Fernando de Goes
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-08T13:06:43Z (GMT). No. of bitstreams: 1 Caiado_AnaCarolinaRochaLima_M.pdf: 12410221 bytes, checksum: 10dff9d1f7b58797480e9a00a97d0a78 (MD5) Previous issue date: 2006
Resumo: Este estudo teve como objetivos: (a) caracterizar a morfologia, a densidade e a área transversal de túbulos dentinários da dentina coronária (profunda) e radicular (terço cervical) intactas e após condicionamento com ácido fosfórico 32% (AF) e primer condicionante do sistema adesivo Clearfill Protect Bond (P); e (b) avaliar e comparar a resistência de união e os padrões de fratura obtidos na dentina coronária (profunda) e dentina radicular (terço cervical). Pré-molares humanos hígidos foram fixados em gluteraldeído (2,5%). Secções da dentina coronária profunda e dentina radicular (região cervical) foram obtidas por clivagem. Cada dente recebeu os seguintes tratamentos: G1- dentina coronária + AF; G2- dentina coronária + P; G3 - dentina coronária sem tratamento; G4- dentina radicular + AF; G5- dentina radicular + P; G6- dentina radicular sem tratamento. As secções condicionadas com primer foram imersas em etanol e acetona. Todos os grupos foram desidratados em concentrações ascendentes de álcool e HMDS e visualizadas por microscopia eletrÃ'nica de varredura em ampliação de 1500X. As imagens obtidas foram usadas para calcular a densidade (D) e a área (A) da secção transversal dos túbulos dentinários em µm2 utilizando o programa Leica IM50. Para o teste de microtração foram utilizados fatias de dentina coronária profunda e dentina radicular cervical de 12 dentes que foram divididas em quatro grupos de acordo com a região dentinária e o sistema adesivo utilizado: G7- dentina radicular + Single Bond II; G8- dentina radicular + Clearfill Protect Bond; G9- dentina coronária + Single Bond II; G10- dentina coronária + Clearfill Protect Bond. Resina composta foi acrescentada em ambos os lados das fatias. Foram obtidas dessas fatias espécimes em forma de palito. Após armazenamento em água (37ºC) os espécimes foram submetidos ao teste de microtração em uma máquina de ensaio universal (Instron), a uma velocidade de 0,5mm/min. A dentina radicular intacta do terço cervical apresentou uma superfície irregular formada por calcosferitos, o que a difere estruturalmente da dentina coronária. Já a densidade (42.627/mm2) e a área transversal média (2,9035/ µm2) dos túbulos dentinários na raiz não revelou diferença estatisticamente significante (p> 0,05) aos valores encontrados na coroa. Os dados de resistência de união foram estatisticamente superiores na dentina coronária (26.63 MPa) do que na dentina radicular (19.76 MPa). O padrão de fratura mais frequentemente encontrado para ambas as regiões foi a fratura mista (coesiva no adesivo e na camada híbrida). ÿ possível concluir que as dentinas coronária (profunda) e radicular do (terço cervical) apresentam diferenças morfológicas e nos valores de resistência de união, porém apresentam semelhanças quanto à densidade de túbulos e padrões de fratura independente do sistema adesivo utilizado
Abstract: The aim of this study was to: (a) characterize the morphology, density and transversal cross-section area of tubules of deep crown and cervical root dentine, intact and after etched with 32% phosphoric acid (AF) or the self-etch primer of the Clearfill Protect Bond adhesive system (P); and (b) evaluate and compare the bond strength and the fracture patterns obtained from deep crown dentine and cervical root dentine. Human carie-free premolars (n=5) were fixed in 25% glutaraldehyde. Deep crown and root dentine sections were obtained by cleavage. Each tooth was treated as follows: G1- crown dentine + AF; G2- crown dentine and P; G3-intact crown dentine; G4- root dentine + AF; G5- root dentine + P; G6- intact root dentine. The sections etched with primer were immersed in ethanol and acetone. All groups were dehydrated in increasing alcohol concentration and Hexamethyldisilazane, nd were visualized by Scanning Electron Microscopy. A magnification of 1500X was used to calculate the density (D) and the dentinal tubule transversal cross-section area per mm2, using the program Leica IM50. For microtensile testing, twelve premolars were cut to obtain slices of deep crown dentine and cervical root dentine. These were divided in four groups according to dentine region and adhesive system employed: G7- root dentine + Single Bond II; G8- root dentine + Clearfill Protect Bond; G9- crown dentine + Single Bond II; G10- crown dentine + Clearfill Protect Bond. Restorative was added to both sides of the slices. Beam specimens were obtained from these restored slices which were kept in water at 37ºC. The specimens were microtensile tested using a universal testing machine (Instrom) at a speed of 0,5mm/min. Intact cervical root dentine presented an irregular surface formed with calcospherites, demonstrating its structural difference from coronary dentine. On the other hand, root dentine tubule density (42,627/mm2) and average transversal area (2.9035/ µm2) did not reveal statistically significant difference (p>0.05) when compared to values obtain in crown. Bond strength results were statistically superior for crown dentine (26.63 MPa) then root dentine (19.76 MPa). Mixed fractures (cohesive in adhesive and hybrid layer) were the most frequent fracture patterns found for both regions. It is possible to conclude that deep crown dentine and cervical root dentine present morphological and bond strength differences, however, are similar in relation to tubule density and fracture patterns independent of the adhesive system employed.
Mestrado
Endodontia
Mestre em Clínica Odontológica
APA, Harvard, Vancouver, ISO, and other styles
23

Neto, Julio Orrico de Aragão Pedra e. Cal. "Estudo aleatório e controlado do uso clínico de um primer autocondicionante na colagem de bráquetes ortodônticos." Universidade do Estado do Rio de Janeiro, 2009. http://www.bdtd.uerj.br/tde_busca/arquivo.php?codArquivo=2853.

Full text
Abstract:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
O uso de primers autocondicionantes tem sido proposto como uma alternativa para a redução de passos clínicos. O objetivo deste estudo clínico aleatório e controlado foi avaliar a performance de um sistema autocondicionante (Transbond Plus Self-Etching Primer, 3M Unitek - SEP) comparado a um sistema multipasso convencional (Transbond XT, 3M Unitek - TBXT) de colagem ortodôntica, durante um período de 12 meses. Vinte e oito pacientes participaram deste estudo, sendo estes alocados aos grupos SEP ou TBXT de forma aleatória, através de randomização em bloco. Um total de 548 bráquetes metálicos (Micro-Arch, prescrição Alexander, GAC International, Bohemia, NY) foram colados com uso da pasta adesiva Transbond XT (3M Unitek), sendo todos os produtos manuseados de acordo com as recomendações dos fabricantes. Foram totalizados 276 bráquetes no grupo controle e 272 no segundo. Curvas de sobrevivência Kaplan-Meier e o teste log-rank (p<0,05) foram utilizados para comparar o percentual de falhas adesivas para as duas técnicas. Ao final do período foram verificadas trinta e duas falhas adesivas (bráquetes descolados), sendo 19 (6,98%) falhas quando utilizado o primer autocondicionante (SEP) e 13 (4,71%) quando usado o primer convencional (TBXT). Não houve diferença significante entre a sobrevivência dos bráquetes entre os dois grupos avaliados (log-rank test, p=0,311). Quando a influência de gênero do paciente, arco dentário e tipo dentário (anterior ou posterior) foram analisados, somente o tipo dentário foi achado significante. Bráquetes de dentes posteriores apresentaram uma maior probabilidade de falha adesiva que os colados em dentes anteriores (p=0,013) Os autores concluem que o primer autocondicionante pode ser utilizado para colagem direta de bráquetes ortodônticos sem que sua sobrevivência clínica seja afetada.
The use of self-etching primers is presented as an alternative to shorten the clinical bonding steps. The purpose of this clinical trial was to evaluate over a 12-month period the performance of a self-etching system (Transbond Plus SEP, 3M Unitek - SEP) compared with a conventional multi-step system (Transbond XT, 3M Unitek - TBXT). Twenty-eight randomly selected patients were included in this study, each being randomly assigned to TBXT or SEP group. A total of 548 brackets were bonded following the manufacturers instructions, using Transbond XT adhesive paste. The survival rate of brackets were estimated with Kaplan-Meier analysis. Bracket survival distributions with respect to bonding procedure, tooth location, dental arch and patient gender were compared with log-rank test. The failure rates of the TBXT and SEP group were 4.71 and 6.98 per cent respectively. No significant differences in the survival rate were observed between the bonding procedures (p=0.311). When the tooth location, dental arch and patient gender were analysed, only the tooth location was found to be significant. Posterior brackets were more likely to fail than the anterior brackets (p=0.013). Both systems had low bonding failure rates and can be considered adequate for orthodontic bonding needs.
APA, Harvard, Vancouver, ISO, and other styles
24

MARRACCINI, TARSO M. "Estudo comparativo do condicionamento do esmalte e dentina para a adesao de resinas compostas com os lasers Er:YAG 2,94 micrometros e com o laser Co sub(2) de 9,6 micrometros." reponame:Repositório Institucional do IPEN, 2002. http://repositorio.ipen.br:8080/xmlui/handle/123456789/11030.

Full text
Abstract:
Made available in DSpace on 2014-10-09T12:47:10Z (GMT). No. of bitstreams: 0
Made available in DSpace on 2014-10-09T14:06:33Z (GMT). No. of bitstreams: 1 08291.pdf: 5207950 bytes, checksum: 64c6335bc7b19848a3ba260e8b738aeb (MD5)
Dissertacao (Mestrado)
IPEN/D
Intituto de Pesquisas Energeticas e Nucleares, IPEN/CNEN-SP
APA, Harvard, Vancouver, ISO, and other styles
25

Balestrin, Elisabete Aparecida. "Dentina: relação entre densidade tubular em diferentes profundidades e a resistência ao cisalhamento de quatro diferentes sistemas adesivos." Universidade de São Paulo, 2009. http://www.teses.usp.br/teses/disponiveis/58/58131/tde-26032010-122840/.

Full text
Abstract:
A dentina em diferentes profundidades apresenta diferentes densidades tubulares e permeabilidades dentinárias, afetando diretamente a adesão dos sistemas adesivos. Objetivos: avaliar a resistência ao cisalhamento de quatro sistemas adesivos e a densidade tubular em diferentes profundidades de dentina. Material e Método: Quatro grupos de dentina de terceiros molares humanos (superior vestibular, superior palatina, inferior vestibular, inferior lingual) foram avaliados quanto à resistência ao cisalhamento (Método ISO 11405) e em microscopia eletrônica de varredura para as profundidades superficial, 0.5, 1.0, 1.5 e 2.0 mm. Os adesivos Adper Single Bond, Xeno III, Clearfil SE Bond e Adper Prompt L-Pop foram selecionados. As análises foram realizadas nos coposde- prova de forma vinculada e os dados submetidos à ANOVA. Resultados: Os resultados dos testes de resistência ao cisalhamento mostraram que os molares superiores apresentaram significância estatística para os fatores profundidade e adesivo, e para as interações profundidade X adesivo, face X profundidade e face X adesivo. Os molares inferiores revelaram significância para os três fatores de variação e para as interações profundidade X adesivo e face X adesivo. O adesivo Xeno III apresentou valores médios superiores tanto nos molares superiores como inferiores. A análise em microscopia eletrônica de varredura revelou aumento da densidade tubular à medida do aumento da profundidade da dentina. Conclusões: Em molares humanos, os fatores profundidade de dentina e sistema adesivo influenciaram a resistência ao cisalhamento. À medida do aumento da profundidade da dentina, a densidade tubular aumenta e a resistência ao cisalhamento diminui, porém esta relação pode ser modificada pelo sistema adesivo
Dentin at various depths presents different tubular density and permeability, thus directly affecting the adhesion of bonding systems. Aim: to evaluate the relationship between tubular density and shear strength of four bonding systems at different dentin depths. Material and methods: upper and lower human molars were analyzed regarding dentin tubular density at different depths by scanning electron microscopy, as well as shear strength (ISO TR 11405 method) for the dependent variables depth (surface dentin, 0.5, 1.0, 1.5 and 2.0 mm), bonding system (total etch and self-etching) and tooth aspect (buccal or palatal/lingual). The bonding systems Single Bond Adper, Xeno III, Clearfil SE Bond e Adper Prompt L-Pop were selected. The analysis were performed in a sampledependent way and results were submitted to the ANOVA test. Results: scanning electron microscopy revealed an increase in tubular density accompanying the depth. Shear strength tests showed that upper molars present significant differences for the factors depth and bonding system, as well as for the interactions depth x bonding system, aspect x depth and aspect x bonding system. Lower molars revealed significance for the three dependent variables and for the interactions depth x bonding system and aspect x bonding system. The Xeno III bonding system presented average values higher than the other products, both in upper and lower molars, in deep dentin (1.0, 1.5 and 2.0), in a regular way. Conclusions: In general, as the dentinal depth increases, so does the tubular density. In human molars, the dependent variables dentin depth and bonding system influenced the shear strength. The self-etching bonding system Xeno III revealed potential maintenance of shear strength when used in dentin at different depths. As dentin depth increases, so does the tubular density, thus lowering shear strength; however, this relationship is dependent on the bonding system used.
APA, Harvard, Vancouver, ISO, and other styles
26

Praxedes, Neto Ot?vio Jos? "Efetividade do fl?or e da escova??o e efic?cia dos materiais de colagem ion?mero de vidro e resina composta na revers?o das microporosidades criadas pelo condicionamento ?cido no esmalte dent?rio." Universidade Federal do Rio Grande do Norte, 2008. http://repositorio.ufrn.br:8080/jspui/handle/123456789/13142.

Full text
Abstract:
Made available in DSpace on 2014-12-17T14:13:27Z (GMT). No. of bitstreams: 1 OtavioJPN.pdf: 2556695 bytes, checksum: 1b00cc54688530c66184271da837d877 (MD5) Previous issue date: 2008-07-31
The objectives of this clinical study was to evaluate the use of the toothpaste with fluoride and without fluoride and the daily tooth brushing are effective in the reversion of the dental enamel conditioned by acid. Another objective of this clinical study was to evaluate if the positioning of orthodontic accessories with glass ionomer cement helps in the reversion of the dental enamel conditioned by acid, when compared to composed resin. One hundred and twenty teeth were selected with indication of extraction by orthodontic reasons. The 30 volunteers were divided, randomly, in two groups. A group used toothpaste without fluoride and the other with it. The teeth of the sample were shuffled, in each volunteer. The teeth were conditioned by the 37% orthophosphoric acid. One of the conditioned teeth stayed in the mouth and suffered action of the abrasion for the tooth brushing, in another teeth a stainless steel mesh protection was positioned with glass ionomer cement, in another tooth the screen was glued with composed resin, in a fourth tooth (the control) was only conditioned after the extractions, 60 days later. All the teeth were appraised through DIAGNOdent, MEVA and EDS. In the obtained data it was possible to observe that there were not statistic significant differences in any comparison, even in the group that did not have access to the fluoride in the toothpaste as in the other that had. According with the used methodology, it was possible to observe too that there was not statistic significant differences in any comparison, even in the group that had the stainless steel mesh positioned with glass ionomer cement as in the group that the stainless steel mesh was positioned with composed resin. However, it was observed that there was an improvement in the topography of the enamel in all the teeth. The accomplishment of this study was facilitated due to the participation of the researchers' of the health area (dentistry), materials engineer, physics and chemistry. The researchers were originating from the Federal University of Rio Grande do Norte and of the University of Queensland, in Australia. This interdisciplinary group was decisive in the accomplishment of the study. It can be concluded that the enamel tends to return to its initial aspect, even if the patient does not have access to fluoride. That is probably due the action of the abrasion for the tooth brushing and mastication. In spite of it not being significant, it is suggested that the conditioned enamel was more resistant to the abrasion in the group that had access to fluoride. It was also possible to conclude that the fluoride liberated by the glass ionomer was not enough to provide a significant difference in the enamel conditioned by the acid, when compared with the composed resin, even in the group that did not use fluoride in the toothpaste as in the group that used
O objetivo deste estudo foi de avaliar o uso do dentifr?cio com fl?or e sem fl?or e a escova??o di?ria na revers?o do esmalte dent?rio condicionado pelo ?cido. Outro objetivo foi de avaliar se a colagem de acess?rios ortod?nticos com ion?mero de vidro auxilia na revers?o do esmalte dent?rio condicionado pelo ?cido. Foram selecionados 120 dentes com extra??o indicada de 30 volunt?rios que foram divididos, leatoriamente, em dois grupos. Um grupo utilizou dentifr?cio sem fl?or e o outro com fl?or. Os dentes foram condicionados pelo ?cido. Um dos dentes condicionados permaneceu na boca e sofreu a??o da abras?o pela escova??o, noutro foi colada uma tela de prote??o com ion?mero de vidro, noutro a tela foi colada com resina composta, num quarto dente (controle) s? foi condicionado ap?s as extra??es, 60 dias depois. Todos os dentes foram avaliados atrav?s do DIAGNOdent, MEVA e EDS. Nos resultados obtidos foi poss?vel observar que n?o houve diferen?a estatisticamente significativa em nenhuma compara??o, tanto no grupo que n?o teve acesso ao fl?or no dentifr?cio como no que teve. Por?m, foi observado que houve uma melhora na topografia do esmalte em todos os dentes. A realiza??o desse trabalho foi facilitada devido ? participa??o de pesquisadores das ?reas da sa?de (odontologia), engenharia dos materiais, f?sica e qu?mica. Os pesquisadores foram oriundos da Universidade Federal do Rio Grande do Norte e da University of Queensland, na Austr?lia. Essa multidisciplinaridade foi decisiva na realiza??o desse estudo. Com esse estudo pode-se concluir que o esmalte tende a retornar o seu aspecto inicial, mesmo que o paciente n?o tenha acesso ao fl?or. Isso se deve provavelmente a a??o da abras?o pela escova??o e mastiga??o. Tamb?m foi poss?vel concluir que o fl?or liberado pelo ion?mero de vidro da colagem do acess?rio ortod?ntico n?o foi suficiente para proporcionar uma diferen?a significativa no esmalte condicionado pelo ?cido. Tanto no grupo que n?o utilizou fl?or no dentifr?cio como no grupo que usou
APA, Harvard, Vancouver, ISO, and other styles
27

Porto, Thiago Soares. "Estudo dos procedimentos utilizados para obtenção de microrretenções na superfície interna da porcelana : avaliação por meio de testes de rugosimetria e microscopia eletrônica de varredura /." Araraquara : [s.n.], 2006. http://hdl.handle.net/11449/89669.

Full text
Abstract:
Orientador: Welingtom Dinelli
Co^orientador:
Banca: José Roberto Cury Saad
Banca: Mânio de Carvalho Tibúrcio
Resumo: O objetivo deste estudo foi avaliar a superfície interna de dois sistemas cerâmicos, após diferentes tratamentos de superfície, avaliação essa feita por meio de rugosimetria e microscopia eletrônica de varredura. Foram utilizadas as seguintes cerâmicas: IPS Empress II (Ivoclar-Vivadent Alemanha) e InCeram Alumina (Vita Zahnfabrick - Alemanha). Foram confeccionadas 50 amostras em forma de pastilha para cada sistema cerâmico de acordo com as especificações dos fabricantes, armazenadas à temperatura ambiente para então serem submetidas ao tratamento superficial, a saber (n=10): sem tratamento (T0) (controle); Ácido fluorídrico (T1); Ácido fluorídrico associado ao jato de óxido de alumínio (T2); Sistema Cojet (T3); Laser Nd:YAG (T4). Para os resultados de rugosidade, padronizaram-se as medidas em Ra, sendo posteriormente realizada a análise estatística por meio de ANOVA e teste de Tukey (p<.001). Para ambos os grupos controle (T0) das cerâmicas testadas, as análises evidenciaram os valores de rugosidade mais inferiores; para o Sistema InCeram Alumina, os tratamentos, ácido fluorídrico (T1), Sistem Cojet (T3)e Laser Nd:YAG (T4), não tiveram diferença estatisticamente significante; já para o Sistema IPS Empress II, todos os tratamentos foram estatisticamente diferentes. As fotomicrografias em microscopia eletrônica de varredura mostraram características diferentes para os tratamentos peculiares para cada sistema cerâmico. Baseado nos dados obtidos pode-se concluir que, quanto ao IPS Empress II, o tratamento com ácido fluorídrico é suficiente, assim como o Sistema CoJet é para o InCeram Alumina. Outros estudos devem ser realizados para que se tenham parâmetros ideais para o tratamento a laser.
Abstract: The present study aimed at evaluating the inner surface of two ceramic systems, after different surface treatments, performed by surface roughness tests and scanning electron microscopy (SEM). IPS Empress II (Ivoclar-Vivadent - Germany) and InCeram Alumina (Vita Zahnfabrick - Germany) were used. Fifty lozenge-shaped samples were made for each ceramic system according to the manufacturers' specifications, and stored at room temperature prior to surface treatment; namely (n=10): non-treated (T0) (control); hydrofluoric acid (T1); hydrofluoric acid associated to airborne particle abrasion (T2); CoJet System (T3); Laser Nd: YAG (T4). Roughness measurement results were standardized in Ra. Analysis of variance (ANOVA) and Tukey test (p<.001) were used to perform the stastistics analysis. For both control groups of the tested ceramics, analyses revealed the lowest roughness values; for the InCeram Alumina System, treatments such as hydrofluoric acid (T1), CoJet System (T3) and Laser Nd:YAG (T4) did not present any statistically significant difference, while for the IPS Empress II System, all treatments were statistically different. Photomicrographs by SEM showed different characteristics for each ceramic system treatment. Based on the resulting data, it can be concluded that the hydrofluoric acid treatment suits the IPS Empress II System, as well as the CoJet System suits the InCeram Alumina System. Further research might be done in order to get ideal parameters for the laser treatment.
Mestre
APA, Harvard, Vancouver, ISO, and other styles
28

Scheffel, Debora Lopes Salles [UNESP]. "Tempo de condicionamento da dentina hígida e afetada por cárie de dentes decíduos e permanentes: efeito na desmineralização do substrato, na produção e na resistência da união resina-dentina." Universidade Estadual Paulista (UNESP), 2010. http://hdl.handle.net/11449/88701.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:23:35Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-03-19Bitstream added on 2014-06-13T18:50:53Z : No. of bitstreams: 1 scheffel_dls_me_arafo.pdf: 1035533 bytes, checksum: e70561f0ad87f4e70ff9fc416abd9379 (MD5)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
O objetivo geral desse trabalho, dividido em três estudos, foi avaliar a influência do tempo de condicionamento ácido na desmineralização da dentina, na qualidade e no desempenho adesivo imediato da união resina-dentina de dentes decíduos e permanentes. No estudo 1, superfícies planas de dentina foram produzidas em molares decíduos e pré-molares (n=8). Sobre cada superfície, três áreas foram delimitadas e condicionadas com ácido fosfórico por 5, 10 ou 15 s. Decorrido o período pré-estabelecido de condicionamento, o ácido foi coletado e a concentração de cálcio dissolvido da dentina (ug Ca/mm2) foi determinada por microcolorimetria. Os dados foram analisados pela aplicação dos testes de ANOVA, Tukey e análise de regressão linear (α=0,05). Correlação positiva significante foi observada entre a concentração de cálcio e o tempo de condicionamento ácido para ambos, dentes decíduos e permanentes. Para todos os tempos de condicionamento, quantidades estatisticamente superiores de íons cálcio foram detectadas para a dentina de dentes decíduos em comparação a dentina de dentes permanentes. Foi concluído que a dentina de dentes decíduos é mais facilmente desmineralizada do que a dentina de dentes permanentes, e que essa desmineralização foi maior em função do aumento do tempo de aplicação do ácido. No estudo 2, superfícies planas de dentina também foram produzidas em outros 8 molares decíduos e 8 pré-molares hígidos. As superfícies foram divididas ao meio no sentido vestíbulo-lingual por meio de uma canaleta produzida com um disco diamantado. Aleatoriamente, cada metade foi condicionada com ácido fosfórico por 15 ou 5 s e os sistemas adesivos Prime&Bond NT ou Prime&Bond 2.1 foram aplicados. Espécimes envolvendo a interface de união foram produzidos e preparados em laboratório...
The aim of this work, divided into three studies, was to evaluate the influence of acid etching time on dentin demineralization, quality and immediate adhesive performance of resin-dentin bonds produced in deciduous and permanent teeth. In the first study, flat dentin surfaces were produced in sound molars (n=8) and premolars (n=8). On each surface, three circular areas were primary defined and etched with phosphoric acid for 5, 10 or 15 s. After the predetermined period of etching, the acid was collected and the calcium concentration (ugCa/mm2) was determined by microcolorimetry. The data were analyzed by ANOVA, Tukey and linear regression tests (α=0.05). Significant positive correlation was observed between calcium concentration and etching time for both deciduous and permanent teeth. For all times of conditioning, statistically higher amounts of calcium ions were removed from dentin of primary teeth compared to dentin of permanent teeth. It was concluded that the primary dentin was more prone to demineralization by phosphoric acid than permanent dentin, and that the extent of demineralization increased as a function of acid etching time. In the second study, flat dentin surfaces were also produced in additional 8 primary molars and 8 premolars. The surfaces were divided into mesial and distal halves through a shallow notch produced with a diamond disc. Randomly, each half was conditioned with 35% phosphoric acid for 15 or 5 s and the adhesive systems Prime & Bond NT or Prime & Bond 2.1 were applied. Specimens involving the bonded interface were produced and processed for staining with Goldner's trichrome. The thickness of the collagen zone exposed at the base of the hybrid layer (ZC) was measured using optical microscopy. Data were submitted to threeway analysis of variance and Tukey’s test (α=0.05). Overall, thicker ZC... (Complete abstract click electronic access below)
APA, Harvard, Vancouver, ISO, and other styles
29

Scheffel, Debora Lopes Salles. "Tempo de condicionamento da dentina hígida e afetada por cárie de dentes decíduos e permanentes : efeito na desmineralização do substrato, na produção e na resistência da união resina-dentina /." Araraquara : [s.n.], 2010. http://hdl.handle.net/11449/88701.

Full text
Abstract:
Orientador: Josimeri Hebling
Banca: Lívia Maria Andaló Tenuta
Banca: Elisa Maria Aparecida Giro
Resumo: O objetivo geral desse trabalho, dividido em três estudos, foi avaliar a influência do tempo de condicionamento ácido na desmineralização da dentina, na qualidade e no desempenho adesivo imediato da união resina-dentina de dentes decíduos e permanentes. No estudo 1, superfícies planas de dentina foram produzidas em molares decíduos e pré-molares (n=8). Sobre cada superfície, três áreas foram delimitadas e condicionadas com ácido fosfórico por 5, 10 ou 15 s. Decorrido o período pré-estabelecido de condicionamento, o ácido foi coletado e a concentração de cálcio dissolvido da dentina (ug Ca/mm2) foi determinada por microcolorimetria. Os dados foram analisados pela aplicação dos testes de ANOVA, Tukey e análise de regressão linear (α=0,05). Correlação positiva significante foi observada entre a concentração de cálcio e o tempo de condicionamento ácido para ambos, dentes decíduos e permanentes. Para todos os tempos de condicionamento, quantidades estatisticamente superiores de íons cálcio foram detectadas para a dentina de dentes decíduos em comparação a dentina de dentes permanentes. Foi concluído que a dentina de dentes decíduos é mais facilmente desmineralizada do que a dentina de dentes permanentes, e que essa desmineralização foi maior em função do aumento do tempo de aplicação do ácido. No estudo 2, superfícies planas de dentina também foram produzidas em outros 8 molares decíduos e 8 pré-molares hígidos. As superfícies foram divididas ao meio no sentido vestíbulo-lingual por meio de uma canaleta produzida com um disco diamantado. Aleatoriamente, cada metade foi condicionada com ácido fosfórico por 15 ou 5 s e os sistemas adesivos Prime&Bond NT ou Prime&Bond 2.1 foram aplicados. Espécimes envolvendo a interface de união foram produzidos e preparados em laboratório... (Resumo completo, clicar acesso eletrônico abaixo)
Abstract: The aim of this work, divided into three studies, was to evaluate the influence of acid etching time on dentin demineralization, quality and immediate adhesive performance of resin-dentin bonds produced in deciduous and permanent teeth. In the first study, flat dentin surfaces were produced in sound molars (n=8) and premolars (n=8). On each surface, three circular areas were primary defined and etched with phosphoric acid for 5, 10 or 15 s. After the predetermined period of etching, the acid was collected and the calcium concentration (ugCa/mm2) was determined by microcolorimetry. The data were analyzed by ANOVA, Tukey and linear regression tests (α=0.05). Significant positive correlation was observed between calcium concentration and etching time for both deciduous and permanent teeth. For all times of conditioning, statistically higher amounts of calcium ions were removed from dentin of primary teeth compared to dentin of permanent teeth. It was concluded that the primary dentin was more prone to demineralization by phosphoric acid than permanent dentin, and that the extent of demineralization increased as a function of acid etching time. In the second study, flat dentin surfaces were also produced in additional 8 primary molars and 8 premolars. The surfaces were divided into mesial and distal halves through a shallow notch produced with a diamond disc. Randomly, each half was conditioned with 35% phosphoric acid for 15 or 5 s and the adhesive systems Prime & Bond NT or Prime & Bond 2.1 were applied. Specimens involving the bonded interface were produced and processed for staining with Goldner's trichrome. The thickness of the collagen zone exposed at the base of the hybrid layer (ZC) was measured using optical microscopy. Data were submitted to threeway analysis of variance and Tukey's test (α=0.05). Overall, thicker ZC... (Complete abstract click electronic access below)
Mestre
APA, Harvard, Vancouver, ISO, and other styles
30

STREFEZZA, CLAUDIA. "Análise da resistência de união adesiva de retentores intrarradiculares metálicos e estéticos cimentados em condutor irradiado com laser de diodo de alta potência (830mm)." reponame:Repositório Institucional do IPEN, 2013. http://repositorio.ipen.br:8080/xmlui/handle/123456789/10562.

Full text
Abstract:
Made available in DSpace on 2014-10-09T12:41:59Z (GMT). No. of bitstreams: 0
Made available in DSpace on 2014-10-09T14:05:51Z (GMT). No. of bitstreams: 0
Tese (Doutoramento)
IPEN/T
Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
APA, Harvard, Vancouver, ISO, and other styles
31

Saavedra, Guilherme de Siqueira Ferreira Anzaloni [UNESP]. "Efeito da neutralização e limpeza sônica do precipitado do ácido fluorídrico sobre a resistência de união entre uma cerâmica feldspática e um cimento resinoso." Universidade Estadual Paulista (UNESP), 2006. http://hdl.handle.net/11449/97416.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-05-12Bitstream added on 2014-06-13T20:58:53Z : No. of bitstreams: 1 saavedra_gsfa_me_sjc.pdf: 2452196 bytes, checksum: b3f2463bbb388a1fe5fbb2276e959c7e (MD5)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
O objetivo deste trabalho foi avaliar três hipóteses: a) o processo de neutralização influencia nos valores de resistência de união entre uma cerâmica feldspática e um cimento resinoso; b) limpeza sônica dos precipitados do ácido fluorídrico aumenta os valores de resistência de união; c) associação entre o do processo de neutralização e a limpeza sônica melhora a resistência de união. Confeccionou-se 32 blocos cerâmicos (VM7 VITA Zahnfabrik), os quais foram duplicados em resina composta (W3D Master). Os resultados deste estudo confirmaram que: a) o processo de neutralização influencia nos valores de resistência de união entre uma cerâmica feldspática e um cimento resinoso; b) a limpeza sônica dos precipitados do ácido fluorídrico aumenta os valores de resistência de união; c) a associação entre o processo de neutralização e a limpeza sônica melhora a resistência de união.
This study evaluated three hypotheses: a) the neutralization process influences the bond strength values between a feldspar ceramic and a resin cement; b) ultrasonic cleaning of hydrofluoric acid precipitates increases the bond strength values; c) association between the neutralization process and ultrasonic cleaning improves the bond strength. The present results confirmed that: a) the neutralization process influences the bond strength values between a feldspar ceramic and a resin cement; b) ultrasonic cleaning of hydrofluoric acid precipitates increases the bond strength values; c) association between the neutralization process and ultrasonic cleaning improves the bond strength.
APA, Harvard, Vancouver, ISO, and other styles
32

Souza, Solange de. "Aparências metalográficas e corrosão seletiva de fases de aços inoxidáveis fundidos austenítico e martensítico atacados potenciostaticamente." Universidade de São Paulo, 1997. http://www.teses.usp.br/teses/disponiveis/88/88131/tde-16092016-111802/.

Full text
Abstract:
A corrosão seletiva de fases de dois tipos de aços inoxidáveis fundidos foi analisada, ao serem submetidos a vários valores constantes de potencial, a partir da região catódica para a anódica da curva de polarização. Os aços estudados foram: austenítico (ACI CF-3M) solubilizado e martensítico (ACI CA-6NM) normalizado e revenido. As curvas de polarização foram traçadas potenciodinamicamente, a uma velocidade de varredura de 0,16 m.V.s-1 em solução aerada contendo H2SO4 1M e NaCl 1M, pH 0,35, à temperatura ambiente. Vários valores de potencial foram selecionados, previamente localizados nas regiões catódica, ativa, passiva e transpassiva da curva de polarização. Potenciostaticamente, foram atingidos os valores de potencial selecionados, sendo eles mantidos fixos por 1800 s. Após o ataque potenciostático, as aparências metalográficas dos aços foram verificadas, desde a região catódica até a anódica. Por microssonda eletrônica, foram quantificados os elementos químicos presentes nas fases dos aços. Para melhor avaliar o início de propagação de pite, foi determinada a porcentagem de íons liberados para o eletrólito, após a imposição de valores de potencial críticos de pite predeterminados pelas curvas de polarização, pelas aparências metalográficas e pelas curvas de densidade de corrente em função do tempo.
The selective corrosion of phases present in two types of cast stainless steels was analyzed, when submitled to several constant values of potential, starting from the cathodic to the anodic regions of the polarization curve. The cast stainless steels were: austenitic (ACI CF-3M) solubilized and martensitic (ACI CA-6NM) normalized and tempered. The polarization curves were obtained at a scanning rate of 0.16 mV.s-1 in 1M H2S04 and 1M NaCI solution, pH 0.35 and at room temperature. Several potential values were selected, previously located in the cathodic, active, passive and transpassive regions of the polarization curve. The values of the selected potential were maintained fixed for 1800 s. After the potentiostatic etching, the metallographic appearances of the steels were verified, from the cathodic to the anodic region. Through electronic microprobe analysis, the present chemical elements were quantified in the phases of the steels. For betler evaluating the beginning of pitling propagation in the studied steels, liberated ion percentage for the solution was determined, after the imposition of critic pitting potential values predetermined from the polarization curves, through the metallographic appearances obtained after potentiostatic etching of the samples and the current density curves as a function of time.
APA, Harvard, Vancouver, ISO, and other styles
33

Lanza, Célia Regina Moreira [UNESP]. "Difusão transdentinária e citotoxicidade de sistemas adesivos autocondicionantes." Universidade Estadual Paulista (UNESP), 2007. http://hdl.handle.net/11449/104262.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:33:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-07-06Bitstream added on 2014-06-13T19:43:57Z : No. of bitstreams: 1 lanza_crm_dr_arafo.pdf: 5945078 bytes, checksum: 092aa2094ca72bbfeb2e0b5301a1b69e (MD5)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Este estudo avaliou a difusão transdentinária e a toxicidade de sistemas adesivos autocondicionantes de diferentes valores de pH sobre células odontoblastóides MDPC-23. Sessenta discos de dentina (0,4 mm de espessura) foram obtidos de terceiros molares humanos hígidos e divididos em 6 grupos após a mensuração de sua condutância hidráulica pelo Flodec. Os discos foram montados em câmaras pulpares in vitro, onde 30.000 células foram plantadas no seu lado pulpar (área dentina exposta 0,28 cm2) e mantidas em cultura por 48 h. Após este período, os sistemas adesivos Clearfil SE Bond, Clearfil Protect Bond, Adper Prompt e Xeno III foram aplicados no lado oclusal dos discos. O sistema adesivo Single Bond foi usado como controle positivo e a solução tampão fosfato como controle negativo. A citotoxicidade foi avaliada após 24 horas pelo teste MTT e a morfologia celular por MEV. A difusão transdentinária foi qualificada por CG/EM. Os valores de MTT para os sistemas autocondicionantes, analisados pelos testes de Kruskall-Wallis e Mann-Whitney, foram estatisticamente diferentes do grupo controle negativo. Houve redução da viabilidade celular de 47,8%; 46,5%; 42,1% e 28,0% para o Clearfil SE Bond, Xeno III, Clearfil Protect Bond e Adper Prompt L-Pop, respectivamente. A redução da viabilidade celular foi inferior ao Single Bond (53,1%) para todos os sistemas. A análise por CG/MS identificou o HEMA como principal componente químico difundido pela dentina. Foi possível concluir que todos os sistemas adesivos autocondicionantes avaliados apresentaram difusão transdentinária resultando em redução do metabolismo celular, a qual não foi relacionada a sua capacidade de dissolução da smear layer e desmineralização da dentina subjancente.
This study evaluated the transdentinal diffusion and cytotoxicity of self-etching adhesive systems with different pH on the odontoblast cell line MDPC-23. Sixty dentin disks were cut from the crowns of extracted human permanent molar teeth with 0.4 mm thickness and were divided into 6 groups of similar hydraulic conductance (Flodec). The dentin disks were placed in an in vitro pulp chamber and 30.000 cells were planted on their pulpal side (area of exposed dentin 0.28 cm2). After 48 hours, the adhesive systems Clearfil SE Bond, Clearfil Protect Bond, Adper Prompt or Xeno III were applied on the occlusal side and light-cured for 10s. Single Bond was used as positive and phosphate buffer solution (PBS) as negative control group. The cytotoxicity was measured by MTT assay and cell characteristics were assessed by SEM, after 24 h. The transdentinal diffusion was qualified by GC/MS. Kruskall-Wallis and Mann-Whitney tests demonstrated a significant difference among the adhesives and PBS (p<0.05). The cellular viability reduction promoted by the self-etching systems was lower than that of Single Bond (53,1%). Cell metabolism was reduced in 47,8%; 46,5%; 42,1% and 28,0% for Clearfil SE Bond, Xeno III, Clearfil Protect Bond and Adper Prompt, respectively. HEMA was identified as the main diffused component. It was concluded that all investigated self-etching adhesives demonstrated transdentinal diffusion resulting in reduction of the cellular metabolism, which was not related to their capacity to dissolve the smear layer and demineralize the underlying dentin.
APA, Harvard, Vancouver, ISO, and other styles
34

Vincenzi, Bárbara. "Efeito do condicionamento ácido e do envelhecimento na resistência da união adesiva de um adesivo universal ao esmalte dental." Universidade Estadual do Oeste do Paraná, 2018. http://tede.unioeste.br/handle/tede/3963.

Full text
Abstract:
Submitted by Edineia Teixeira (edineia.teixeira@unioeste.br) on 2018-10-03T14:30:06Z No. of bitstreams: 2 Bárbara_Vincenzi2018.pdf: 1279106 bytes, checksum: d44d41a7b8387c799cad466834f2786c (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Made available in DSpace on 2018-10-03T14:30:06Z (GMT). No. of bitstreams: 2 Bárbara_Vincenzi2018.pdf: 1279106 bytes, checksum: d44d41a7b8387c799cad466834f2786c (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2018-03-28
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES
Purpose: To evaluate the performance of an universal restorative adhesive system (total- and self-etching mode) on bond strength (BS) to the enamel immediately and after 12 months. Materials and methods: Eleven human third molars were sectioned in half to obtain twenty-two samples. The proximal enamel surfaces were planned, polished and randomly divided into 2 groups according to the treatment, and these subdivided (2 groups) according to the storage time, making 4 groups (n = 11): CAI (Scotchbond Universal adhesive-SBU, with prior 37% phosphoric acid conditioning for 15 sec, analyzed immediately); CA12m (same treatment as CAI, analyzed after 12 months aging); SAI group (SBU without prior acid conditioning, analyzed immediately); SA12m (same treatment as SAI, analyzed after 12 months aging). All samples were restored with Scothbond Universal adhesive (SBU) and Filtek Z100 composite resin according to the manufacturer's instructions. The composite resin blocks were built up incrementally. The specimens were stored in deionized for 24 hours and sectioned in sticks (1.0 ± 0.2 mm area) and subjected to microtensile on test machine on 0.5mm/min immediately (24h) and after 12 months . Data were submitted to ANOVA two criteria (p <0.01) followed by the Tukey post-test (p<0.05). Results: Enamel acid etching promoted a significant increase in RU values after immediate traction. However, after 12 months, RU values decreased significantly, with no statistical difference between the groups with and without acid conditioning. Conclusions: Enamel conditioning increased the immediate bond strength of the universal adhesive, and aging after 12 months reduced it.
Objetivos: Avaliar o desempenho de um sistema adesivo restaurador universal (modo convencional e autocondicionante) na resistência de união (RU) ao esmalte em período imediato e após 12 meses. Materiais e métodos: Onze terceiros molares humanos hígidos foram seccionados ao meio para obter vinte e duas amostras. As superfícies proximais do esmalte foram planificadas, polidas e aleatoriamente divididas em 2 grupos de acordo com o tratamento, e estes subdivididos (2 grupos) de acordo com o tempo de estocagem, perfazendo 4 grupos (n=11): CAI (adesivo Scotchbond Universal-SBU, prévio condicionamento com ácido fosfórico por 15 seg, análise imediata); CA12m (mesmo tratamento do CAI, análise após envelhecimento de 12 meses); SAI (adesivo SBU sem condicionamento ácido prévio, análise imediata); SA12m (mesmo tratamento do SAI, análise após 12 meses). Todas as amostras foram restauradas com o adesivo Scothbond Universal (SBU) e resina composta Filtek Z100 de acordo com as instruções do fabricante. Os blocos de resina composta foram construídos incrementalmente. Os espécimes foram armazenados em água destilada por 24h, e posteriormente seccionados em palitos (área 1,0 ± 0,2mm) que foram submetidos ao teste de microtração em máquina de teste a 0.5mm/min imediatamente (24h) e 12 meses após. Os dados foram submetidos a ANOVA dois critérios (p <0.01) seguido pelo pós-teste de Tukey (p<0,05). Resultados: O condicionamento ácido do esmalte promoveu aumento significativo dos valores de RU após tração imediata. No entanto, após 12 meses, os valores de RU diminuíram significativamente, sem diferença estatística entre os grupos com e sem condicionamento ácido. Conclusões: O condicionamento do esmalte aumentou a resistência de união adesiva do adesivo universal imediata, e o envelhecimento após 12 meses a reduziu.
APA, Harvard, Vancouver, ISO, and other styles
35

Soares, Ana Flávia. "Comprometimento do esmalte bovino após escovação em função do condicionamento ácido, clareamento ativado com luz híbrida, concentração e pH dos géis clareadores." Universidade de São Paulo, 2013. http://www.teses.usp.br/teses/disponiveis/25/25148/tde-05042013-145654/.

Full text
Abstract:
Este estudo in vitro avaliou a influência do clareamento ativado com luz híbrida, em função da variação do pH e concentração de géis clareadores, e do condicionamento ácido prévio do esmalte bovino na alteração da rugosidade e desgaste após escovação simulada. Fragmentos de esmalte (1,5cm x 0,5cm x 0,4cm) foram divididos em duas partes, ficando uma metade como controle e a outra como área teste. Esta última foi subdividida em duas metades, sendo que uma recebeu o condicionamento ácido somado ao gel clareador e a outra somente o gel clareador. Os espécimes foram divididos aleatoriamente em seis grupos (n=10): C = controle; TBO35LH = Total Blanc Office 35% 1 sessão (5x8) + ativação com luz híbrida LED/Laser; LPS35LH= Lase Peroxide Sense 35% - 1 sessão (5x8) + ativação com luz híbrida LED/Laser; LPS25LH = Lase Peroxide Sense 25% - 1 sessão (5x8) + ativação com luz híbrida LED/Laser; LPL15LH = Lase Peroxide Lite 15% - 1 sessão (5x8) + ativação com luz híbrida LED/Laser; LPL10LHV = Lase Peroxide Lite 10% - 1 sessão (5x8) + ativação com luz híbrida LED/Laser violeta. A rugosidade aritmética (Ra) inicial, após clareamento e após escovação, foi determinada pela média (μm) de três leituras (em cada área sem e com ácido totalizando seis leituras por espécimes) com o rugosímetro Hommel Tester T 1000. Os valores médios do pH foram determinados pelo peagômetro digital Sentron Model 1001 nos tempos inicial e final. Os espécimes foram armazenados em saliva artificial por sete dias, submetidos a 100.000 ciclos de escovação simulada. Após 24 horas o desgaste superficial foi determinado (μm) empregando o mesmo rugosímetro. Em relação ao desgaste e a alteração de rugosidade superficial, os resultados foram submetidos à Anova a dois critérios e a dois critérios de medidas repetidas e posteriormente ao teste de Tukey. Os dados obtidos das leituras de pH foram submetidos à ANOVA a um critério e a dois critérios de medidas repetidas e ao teste de Kruskal Wallis e Tukey para comparações individuais entre os grupos. Para todos os testes o nível de significância foi de 5%. A rugosidade e o desgaste apontaram diferenças estatísticas entre os grupos, principalmente quando comparado à área com e sem ácido. Os géis clareadores apresentaram tendência de diminuição dos valores de pH do tempo inicial para o tempo final, contudo, uma correlação com a rugosidade e com o desgaste não pôde ser estabelecida de forma clara.
This in vitro study evaluated the influence of whitening activated with hybrid light on the function variations of the pH level and concentration of bleaching gels and prior acid etching of bovine enamel and the change in roughness and wear after simulated tooth brushing. Fragments of enamel (1.5 cm x 0.5 cm x 0.4 cm) were divided into two parts, one half as the control and the other as the test area. The latter was divided into two halves, one of which received the etching added to the whitening gel and the other with only the whitening gel. The specimens were randomly divided into six groups (n = 10): C = control; TBO35LH = 35% Total Blanc Office 1x session (5x8\') + activation with hybrid light LED/Laser; LPS35LH = 35% Lase Peroxide Sense - 1x session (5x8\') + activation with hybrid light LED/Laser; LPS25LH = 25% Sense Lase Peroxide - 1x session (5x8\') + activation with hybrid light LED/Laser; LPL15LH = 15% Lase Peroxide Lite - 1x session (5x8 \') + activation with hybrid light LED/Laser; LPL10LHV = 10% Lase Peroxide Lite - 1x session (5x8\') + activation with violet hybrid light LED/Laser. The arithmetic roughness (Ra) started after bleaching and after brushing was determined by averaging (μm) the three readings (in each area - with and without acid for a total of six readings per specimen) with a Rugosimeter Hommel Tester T 1000. The mean pH values were determined by the Sentron Model 1001 digital pH meter at the start and end times. The specimens were stored in artificial saliva for seven days, and subjected to 100,000 cycles of simulated brushing. After 24 hours, the surface wear was determined (μm) employing the same roughness meter. In relation to the change in wear and surface roughness, the results were evaluated by two way ANOVA testing for repeated measures and later, a Tukey\'s test. The data obtained from the pH readings were submitted to two way ANOVA testing for repeated measures and the Kruskal Wallis and Tukey tests for the comparisons between the individual groups. The significance level was set at 5% for all the tests. The roughness and wear showed statistical differences between the groups, especially when compared to the area with and without acid. The bleaching gels tended to decrease in pH from the starting time to the final time, however, a correlation with the roughness and wear could not be clearly established.
APA, Harvard, Vancouver, ISO, and other styles
36

Lanza, Célia Regina Moreira. "Difusão transdentinária e citotoxicidade de sistemas adesivos autocondicionantes /." Araraquara : [s.n.], 2007. http://hdl.handle.net/11449/104262.

Full text
Abstract:
Orientador: Josemeri Hebling
Banca: Roberval de Almeida Cruz
Banca: José Carlos Pereira
Banca: Elisa Maria Aparecida Giro
Banca: Carlos Alberto dos Santos Cruz
Resumo: Este estudo avaliou a difusão transdentinária e a toxicidade de sistemas adesivos autocondicionantes de diferentes valores de pH sobre células odontoblastóides MDPC-23. Sessenta discos de dentina (0,4 mm de espessura) foram obtidos de terceiros molares humanos hígidos e divididos em 6 grupos após a mensuração de sua condutância hidráulica pelo Flodec. Os discos foram montados em câmaras pulpares in vitro, onde 30.000 células foram plantadas no seu lado pulpar (área dentina exposta 0,28 cm2) e mantidas em cultura por 48 h. Após este período, os sistemas adesivos Clearfil SE Bond, Clearfil Protect Bond, Adper Prompt e Xeno III foram aplicados no lado oclusal dos discos. O sistema adesivo Single Bond foi usado como controle positivo e a solução tampão fosfato como controle negativo. A citotoxicidade foi avaliada após 24 horas pelo teste MTT e a morfologia celular por MEV. A difusão transdentinária foi qualificada por CG/EM. Os valores de MTT para os sistemas autocondicionantes, analisados pelos testes de Kruskall-Wallis e Mann-Whitney, foram estatisticamente diferentes do grupo controle negativo. Houve redução da viabilidade celular de 47,8%; 46,5%; 42,1% e 28,0% para o Clearfil SE Bond, Xeno III, Clearfil Protect Bond e Adper Prompt L-Pop, respectivamente. A redução da viabilidade celular foi inferior ao Single Bond (53,1%) para todos os sistemas. A análise por CG/MS identificou o HEMA como principal componente químico difundido pela dentina. Foi possível concluir que todos os sistemas adesivos autocondicionantes avaliados apresentaram difusão transdentinária resultando em redução do metabolismo celular, a qual não foi relacionada a sua capacidade de dissolução da smear layer e desmineralização da dentina subjancente.
Abstract: This study evaluated the transdentinal diffusion and cytotoxicity of self-etching adhesive systems with different pH on the odontoblast cell line MDPC-23. Sixty dentin disks were cut from the crowns of extracted human permanent molar teeth with 0.4 mm thickness and were divided into 6 groups of similar hydraulic conductance (Flodec). The dentin disks were placed in an in vitro pulp chamber and 30.000 cells were planted on their pulpal side (area of exposed dentin 0.28 cm2). After 48 hours, the adhesive systems Clearfil SE Bond, Clearfil Protect Bond, Adper Prompt or Xeno III were applied on the occlusal side and light-cured for 10s. Single Bond was used as positive and phosphate buffer solution (PBS) as negative control group. The cytotoxicity was measured by MTT assay and cell characteristics were assessed by SEM, after 24 h. The transdentinal diffusion was qualified by GC/MS. Kruskall-Wallis and Mann-Whitney tests demonstrated a significant difference among the adhesives and PBS (p<0.05). The cellular viability reduction promoted by the self-etching systems was lower than that of Single Bond (53,1%). Cell metabolism was reduced in 47,8%; 46,5%; 42,1% and 28,0% for Clearfil SE Bond, Xeno III, Clearfil Protect Bond and Adper Prompt, respectively. HEMA was identified as the main diffused component. It was concluded that all investigated self-etching adhesives demonstrated transdentinal diffusion resulting in reduction of the cellular metabolism, which was not related to their capacity to dissolve the smear layer and demineralize the underlying dentin.
Doutor
APA, Harvard, Vancouver, ISO, and other styles
37

Porto, Thiago Soares [UNESP]. "Estudo dos procedimentos utilizados para obtenção de microrretenções na superfície interna da porcelana: avaliação por meio de testes de rugosimetria e microscopia eletrônica de varredura." Universidade Estadual Paulista (UNESP), 2006. http://hdl.handle.net/11449/89669.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-11-30Bitstream added on 2014-06-13T19:10:18Z : No. of bitstreams: 1 porto_ts_me_arafo.pdf: 998293 bytes, checksum: 6183c4e4dea84be0c45e2947766bf407 (MD5)
O objetivo deste estudo foi avaliar a superfície interna de dois sistemas cerâmicos, após diferentes tratamentos de superfície, avaliação essa feita por meio de rugosimetria e microscopia eletrônica de varredura. Foram utilizadas as seguintes cerâmicas: IPS Empress II (Ivoclar-Vivadent Alemanha) e InCeram Alumina (Vita Zahnfabrick - Alemanha). Foram confeccionadas 50 amostras em forma de pastilha para cada sistema cerâmico de acordo com as especificações dos fabricantes, armazenadas à temperatura ambiente para então serem submetidas ao tratamento superficial, a saber (n=10): sem tratamento (T0) (controle); Ácido fluorídrico (T1); Ácido fluorídrico associado ao jato de óxido de alumínio (T2); Sistema Cojet (T3); Laser Nd:YAG (T4). Para os resultados de rugosidade, padronizaram-se as medidas em Ra, sendo posteriormente realizada a análise estatística por meio de ANOVA e teste de Tukey (p<.001). Para ambos os grupos controle (T0) das cerâmicas testadas, as análises evidenciaram os valores de rugosidade mais inferiores; para o Sistema InCeram Alumina, os tratamentos, ácido fluorídrico (T1), Sistem Cojet (T3)e Laser Nd:YAG (T4), não tiveram diferença estatisticamente significante; já para o Sistema IPS Empress II, todos os tratamentos foram estatisticamente diferentes. As fotomicrografias em microscopia eletrônica de varredura mostraram características diferentes para os tratamentos peculiares para cada sistema cerâmico. Baseado nos dados obtidos pode-se concluir que, quanto ao IPS Empress II, o tratamento com ácido fluorídrico é suficiente, assim como o Sistema CoJet é para o InCeram Alumina. Outros estudos devem ser realizados para que se tenham parâmetros ideais para o tratamento a laser.
The present study aimed at evaluating the inner surface of two ceramic systems, after different surface treatments, performed by surface roughness tests and scanning electron microscopy (SEM). IPS Empress II (Ivoclar-Vivadent – Germany) and InCeram Alumina (Vita Zahnfabrick – Germany) were used. Fifty lozenge-shaped samples were made for each ceramic system according to the manufacturers’ specifications, and stored at room temperature prior to surface treatment; namely (n=10): non-treated (T0) (control); hydrofluoric acid (T1); hydrofluoric acid associated to airborne particle abrasion (T2); CoJet System (T3); Laser Nd: YAG (T4). Roughness measurement results were standardized in Ra. Analysis of variance (ANOVA) and Tukey test (p<.001) were used to perform the stastistics analysis. For both control groups of the tested ceramics, analyses revealed the lowest roughness values; for the InCeram Alumina System, treatments such as hydrofluoric acid (T1), CoJet System (T3) and Laser Nd:YAG (T4) did not present any statistically significant difference, while for the IPS Empress II System, all treatments were statistically different. Photomicrographs by SEM showed different characteristics for each ceramic system treatment. Based on the resulting data, it can be concluded that the hydrofluoric acid treatment suits the IPS Empress II System, as well as the CoJet System suits the InCeram Alumina System. Further research might be done in order to get ideal parameters for the laser treatment.
APA, Harvard, Vancouver, ISO, and other styles
38

Martini, Eveline Claudia. "EFEITO DA TÉCNICA DE APLICAÇÃO DO EDTA COMO PRÉ- CONDICIONAMENTO DA DENTINA ESCLERÓTICA E ESMALTE NA RESISTÊNCIA DE UNIÃO DE ADESIVOS UNIVERSAIS." UNIVERSIDADE ESTADUAL DE PONTA GROSSA, 2016. http://tede2.uepg.br/jspui/handle/prefix/1700.

Full text
Abstract:
Made available in DSpace on 2017-07-24T19:21:57Z (GMT). No. of bitstreams: 1 Eveline Claudia Martini.pdf: 1398008 bytes, checksum: 843a0d30d9ab95c12dc193d9bc916fba (MD5) Previous issue date: 2016-02-03
The aim of this study was to investigate the effect of different protocols of 17% EDTA (ethylene diamine tetra acetic acid) pre-conditioning on the etching pattern and immediate bond strength of universal adhesives to enamel and sclerotic dentin. Forty bovine teeth with sclerotic dentin and twenty human third molars were randomly divided into eight groups resulting from the combination of the main factors surface treatment (none, 2-min EDTA conditioning manual application; 30-second EDTA manual application; 30-second EDTA sonic application) and adhesive system (Scotchbond Universal Adhesive [SBU] and Prime & Bond Elect [PBE]). Resin-dentin and enamel-dentin bonded specimens were prepared and tested under the microtensile bond strength (μTBS) and microshear bond strength (μSBS) tests respectively. The etching patterns produced on the enamel and on the sclerotic dentin surfaces were evaluated under scanning electron microscope (SEM). Results:None of the EDTA pre-conditioning protocols had any impact on the μSBS on enamel (p > 0.05). In sclerotic dentin, the lowest μTBS was observed in the group without EDTA pre-conditioning and the highest in the 30-second EDTA sonic application group. SBU showed the highest μTBS for all the groups (p < 0.05). EDTA preconditioning improved the etching pattern of enamel and dentin in all groups. EDTA pre-conditioning improved the bonding performance and etching pattern of the universal adhesives used in the self-etch mode on sclerotic dentin, mainly when applied for 30 s with the aid of a sonic device. EDTA pre-treatment also improved the retentive etching pattern on enamel but it did not result in higher enamel bond strength.
O objetivo deste estudo foi investigar o efeito de diferentes protocolos de précondicionamento com ácido etilenodiamino tetra-acético (EDTA) a 17% na resistência de união (RU) e padrão de condicionamento para adesivos universais no modo autocondicionante em esmalte e dentina esclerótica. Quarenta dentes bovinos com dentina esclerótica e vinte terceiros molares humanos foram divididos aleatoriamente em oito grupos resultantes da combinação dos fatores principais tratamento de superfície (controle, aplicação manual de EDTA por 2 min; aplicação manual de EDTA por 30 s; aplicação sônica de EDTA por 30 s) e os sistemas adesivos (Single Bond Universal [SBU] e Prime & Bond Elect [PBE]). Espécimes de resina-dentina e de resina-esmalte foram preparados e testados quanto à RU por microtração e por microcisalhamento, respectivamente. Os dados foram submetidos à análise de variância de dois fatores (adesivo e modo de aplicação) e teste de Tukey (α = 5%). O padrão de condicionamento produzido sobre a superfície de esmalte e de dentina esclerosada foi avaliada qualitativamente em microscópio eletrônico de varredura (MEV). Nenhum dos protocolos de EDTA influenciou a resistência de união ao esmalte (p > 0,05). Na dentina esclerótica, os menores valores de RU foram observados sem tratamento com EDTA e o maior valor foi observado no grupo de aplicação sônica de EDTA por 30 s, tendo os demais grupos desempenho intermediário. Tanto em esmalte como em dentina, o adesivo SBU apresentou maiores valores de RU em todos os grupos (p < 0,05). Um melhor padrão de condicionamento foi observado após tratamento com EDTA em relação ao grupo sem tratamento prévio de EDTA. O pré-condicionamento com EDTA melhorou a RU e o padrão de condicionamento de adesivos universais aplicados no modo autocondicionante sobre a dentina esclerótica, principalmente quando aplicada com dispositivo sônico durante 30 s. Em esmalte, o condicionamento prévio com EDTA melhorou o padrão de condicionamento, porém não resultou em maior RU.
APA, Harvard, Vancouver, ISO, and other styles
39

Romano, Juliana Jendiroba Faraoni. "Avaliação do desgaste superficial do esmalte e da dentina radicular submetidos ao tratamento clareador: in vitro e in situ." Universidade de São Paulo, 2008. http://www.teses.usp.br/teses/disponiveis/58/58133/tde-30082010-094935/.

Full text
Abstract:
Devido a alterações químico-estruturais causadas pelo clareamento, os substratos dentais poderiam tornar-se mais susceptíveis a perda tecidual, principalmente se expostos a desafios erosivo/abrasivos. Desta forma, o presente estudo teve como objetivos: 1) analisar in vitro, se o esmalte e a radicular dentina clareada com diferentes agentes e concentrações, apresenta uma maior susceptibilidade ao desgaste, quando submetido a ciclos de erosão e abrasão; 2) comparar o efeito da aplicação de um agente clareador a base de peróxido de carbamida a 10% a um placebo no desgaste do esmalte e da dentina radicular, através de um modelo in situ. Os resultados do estudo in vitro mostraram que, independentemente do agente usado, o clareamento não aumentou o desgaste do esmalte frente a episódios erosivo-abrasivos. Na dentina, o desgaste foi dependente do agente clareador aplicado. Baseado no protocolo in situ adotado, o peróxido de carbamida a 10% não causou maior desgaste superficial no esmalte, mas aumentou a perda de tecido dentinário comparado ao placebo. Pode-se concluir que, em termos de desgaste superficial, o esmalte não foi afetado pelo tratamento clareador, enquanto a dentina mostrou-se mais susceptível. Assim, sugerem-se cuidados adicionais na seleção do agente clareador em situações clínicas que apresentam dentina radicular exposta.
Due to the chemical and microstructural alterations caused by bleaching, the dental substrates can become more susceptible to tissue loss, mainly if exposed to erosive/abrasive challenges. Therefore, the present study had the following objectives: 1) to analyze in vitro, if enamel and root dentin that had been bleached with different agents and concentrations, were at increased risk of wear when submitted to cycles of erosion and abrasion; 2) to compare the effect of the application of a 10% carbamide peroxide bleaching agent to a placebo on wear of enamel and root dentin, through an in situ model. The results of the in vitro study showed that independent of agent used, the bleaching demonstrated no increase in the wear of enamel when exposed to the erosive-abrasive episodes. In dentin, the wear was dependent on the bleaching agent applied. Based on the in situ protocol adopted, the 10% carbamide peroxide did not cause higher wear on the enamel, but increased the wear of the root dentin compared to the placebo. It could be concluded that in terms of superficial wear, enamel was not affected by bleaching treatment, while dentin showed to be more susceptible. Thus, additional caution is suggested in the choice of the bleaching agent when root dentin is exposed.
APA, Harvard, Vancouver, ISO, and other styles
40

Wandscher, Vinicius Felipe. "Retenção de coroas de zircônia: estudo de diferentes condições de tratamento interno de coroas em zirconia e do núcleo em resina composta." Universidade Federal de Santa Maria, 2017. http://repositorio.ufsm.br/handle/1/11897.

Full text
Abstract:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES
The present thesis was structured in two scientific articles that investigated the adhesion of zirconium oxide ceramic crowns. The first article aimed to evaluate different methods for silica deposition at the inner surface of Y-TZP crowns by means of a retention test. A hundred simplified full-crown preparations obtained from fiber-reinforced polymer were scanned and 100 zirconium oxide crowns with occlusal retention were machined. The preparation/crown assemblies were randomly divided in 5 groups according to the inner surface treatment: TBS – tribochemical silica coating with silica-coated alumina particles (30 μm); GHF1 – application of a thin glaze layer + hydrofluoric acid for 1 min; GHF5 – glaze application + hydrofluoric acid for 5 min; GHF15 – glaze application + hydrofluoric acid for 15 min; and Nano – silica nanofilm deposition (5 nm) via magnetron sputtering. All groups received silane coupling agent application. The preparations surfaces were etched with 10% hydrofluoric acid for 30 s and silanized. Crowns were cemented with resin cement, thermocycled (12.000 cycles; 5 / 55 °C), stored for 60 days and submitted to retention test (0.5 mm/min until failure). Retention data (MPa) were statistically analyzed by one way– ANOVA and Tukey test, as well as Weibull analysis. Failures were classified as 50C (above 50% of cement in the crown) and 50S (above 50% of cement on the substrate). TBS (5.6 ± 1.7 MPa) and Nano (5.5 ± 1 MPa) groups showed higher retention values than the other groups (p<0.0001), as well as higher characteristic strength (6.18 e 5.91, respectively). There was no difference for Weibull modulus, except for GHF1 group, which showed statistically inferior value. TBS and GHF15 presented, respectively, 60% and 70% of the failures classified as 50C, while the other groups had 50S as most part of the failures. Air-abrasion with silica-coated alumina particles and silica nanofilm deposition on the inner surface of Y-TZP crowns generated higher retention values. The second article evaluated the retention of zirconia crowns cemented to aged composite cores and prepared with burs of different grit sizes. Sixty simplified full-crown preparations were fabricated with composite resin and scanned. Sixty zirconium oxide crowns with occlusal retention were machined. The composite resin cores were stored for 120 days in humid environment at 37 °C and randomly divided in 3 groups (n=20) according to the finishing of the composite resin core: CTRL (control) – no treatment; EFB – extra-fine diamond bur (25 μm); and CB – coarse diamond bur (107 μm). Superficial grinding was performed with an adapted surveyor to standardize speed and pressure. The inner surfaces of the crowns were air-abraded with silica-coated alumina particles (30 μm) and a silane coupling agent was applied. Crowns were cemented with a self-adhesive resin cement (RelyX U200). Then, the assemblies core/crown were thermocycled (12.000 cycles; 5/55°C), stored for 120 days and submitted to retention test (0.5 mm/min until failure). Tesile date (MPa were analyzed by one way- ANOVA and Tukey test (p≤0,05), as well as Weibull analysis. Failures were classified as 50C (above 50% of cement adhered in the crown), 50S (above 50% of cement adhered on the resin substrate) and COE (cohesive failure of the core). No statistical difference was observed for the retention values (p=0.975), but the control group (CTRL) showed higher Weibull modulus. The predominant failure mode was 50S. The occurrence of cohesive failures was higher on the control group. Retention of the zirconium oxide crowns was not affected by the core roughness. It was concluded that air-abrasion followed by silane application and silica nanofilms deposition improve the retention of zircônia crowns, as well as finishing of resin cores with diamond burs does not influence the retention of zirconia crowns.
A presente tese foi estruturada em dois artigos científicos que investigaram a adesão de coroas de cerâmicas à base de óxido de zircônio. O primeiro artigo objetivou avaliar diferentes métodos de deposição de sílica na superfície interna de coroas de Y-TZP por meio de teste de retenção. Para isso, 100 preparos simplificados para coroa total produzidos a partir de polímeros reforçados por fibras com foram escaneados e 100 coroas em óxido de zircônio com retenções oclusais foram usinadas. Os conjuntos preparo/coroa foram divididos de forma randômica em 5 grupos (n=20) de acordo com o tratamento da superfície interna: TBS- jateamento com partícula de alumina revestida por sílica (30 μm); GHF1- aplicação de fina camada de glaze + ácido fluorídrico por 1 min; GHF5- aplicação de glaze + ácido fluorídrico por 5 min; GHF15- aplicação de glaze + ácido fluorídrico por 15 min; e Nano- deposição de nanofilme de sílica (5 nm) via desbastamento iônico. Todos os grupos receberam aplicação de um agente de união silano. As superfícies dos preparos foram condicionadas com ácido fluorídrico 10% por 30 s e silanizadas. As coroas foram cimentadas com um cimento resinoso, termocicladas (12.000 ciclos; 5 / 55 °C), armazenadas por 60 dias e submetidas ao teste de retenção (0.5 mm/min até a falha). Os dados de retenção (MPa) foram analisados estatisticamente utilizando-se ANOVA- um fator e teste de Tukey (p≤0,05), além da análise de Weibull. As falhas foram classificadas em 50C (acima de 50% do cimento aderido na coroa) e 50S (acima de 50% de cimento no substrato). Os grupos TBS (5.6 ± 1.7 MPa) e Nano (5.5 ± 1 MPa) apresentaram maiores valores de retenção do que os demais grupos (p<0.0001), assim como maiores valores de resistência característica (6.18 e 5.91, respectivamente). Não houve diferença no módulo de Weibull exceto para o grupo GHF1, que apresentou valor estatisticamente inferior. Os grupos TBS e GHF15 apresentaram, respectivamente, 60 e 70% de suas falhas classificadas como 50C, enquanto os outros grupos apresentaram a maior parte das falhas 50S. O jateamento com partículas de alumina revestidas por sílica e a deposição de nanofilme de sílica na superfície interna de coroas de Y-TZP promoveram maiores valores de retenção. O segundo artigo avaliou a retenção de coroas de zircônia cimentadas em núcleos protéticos envelhecidos construídos em resina composta e preparados com brocas diamantadas de diferentes granulações. Para isso, 60 preparos simplificados para coroa total foram confeccionados em resina composta e escaneados. Sessenta coroas à base de óxido de zircônio com retenções oclusais foram usinadas. Os preparos em resina composta foram armazenados por 120 dias em ambiente úmido a 37 °C e randomicamente divididos em 3 grupos (n=20) de acordo com o tipo de finalização do núcleo em resina: CTRL (controle) – sem tratamento; EFB – broca diamantada extrafina (25 μm); e CB – broca grossa (107 μm). O desgaste superficial foi realizado por meio de um paralelômetro adaptado com o objetivo de padronizar a velocidade e a pressão de desgaste. As superfícies internas das coroas foram jateadas com partículas de alumina revestidas por sílica (30 μm) e então um agente de união silano foi aplicado. As coroas foram cimentadas com um cimento resinoso autoadesivo (RelyX U200). Então, os conjuntos núcleo/coroa foram termociclados (12.000 ciclos; 5/55°C), armazenados por 120 dias e submetidos ao teste de retenção (0.5 mm/min até a falha). Os dados de tração (MPa) foram analisados por meio de ANOVA- um fator e teste de Tukey (p≤0,05), assim como análise de Weibull. As falhas foram classificadas como 50C (mais que 50% de cimento aderido na coroa), 50S (mais que 50% de cimento aderido ao substrato de resina) e COE (fratura coesiva do núcleo). Nenhuma diferença estatística foi observada nos valores de retenção (p=0.975), porém o grupo controle (CTRL) apresentou o maior módulo de Weibull. O tipo de falha predominante foi 50S. A ocorrência de falhas coesivas foi maior no grupo controle. A retenção das coroas à base de óxido de zircônio não foi afetada pela rugosidade do núcleo. Concluiu-se que jateamento seguido de silano e deposição de nanofilmes de sílica aumentam a retenção de coroas de zircônia, assim como o acabamento de núcleos de resina com pontas diamantadas não influencia a retenção de coroas de zircônia.
APA, Harvard, Vancouver, ISO, and other styles
41

Ocampo, Jessica Bedoya. "Influência do tempo de condicionamento e viscosidade do ácido metafosfórico 40% nas propriedades adesivas da interface radicular." Universidade Estadual de Ponta Grossa, 2018. http://tede2.uepg.br/jspui/handle/prefix/2481.

Full text
Abstract:
Submitted by Eunice Novais (enovais@uepg.br) on 2018-05-02T20:14:07Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Jessica Ocampo.pdf: 4941603 bytes, checksum: 1518afa0052f5db521e43d80239d1e19 (MD5)
Made available in DSpace on 2018-05-02T20:14:07Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Jessica Ocampo.pdf: 4941603 bytes, checksum: 1518afa0052f5db521e43d80239d1e19 (MD5) Previous issue date: 2018-02-23
Avaliar in vitro a influência dos diferentes tempos de condicionamento do ácido metafosfórico 40% e ácido ortofosfórico 37% em diferentes viscosidades nas propriedades adesivas da interface radicular. As raízes de 72 pré-molares inferiores uniradiculares foram preparadas, tratadas endodonticamente e distribuídas aleatoriamente em 8 condições experimentais (n=9) de acordo com a combinação das variáveis: Ácido [ácido ortofosfórico 37% (AOF) e ácido metafosfórico 40% (AMF)], viscosidade do ácido [(gel (G) e líquido (L)] e tempos de aplicação (7 e 15 s). Sessenta e quatro raízes foram cimentadas com sistema adesivo Ambar Universal e o cimento dual Allcem Core. Após a cimentação, os dentes foram seccionados transversalmente em fatias e submetidas ao teste de resistência de união por Push-out (RU) (n=6). Para o teste de nanoinfiltração (NI), fatias de cada grupo foram imersas em solução de nitrato de prata para análise por Microscopia eletrônica de varredura (MEV). Para análise morfológica da superfície radicular, os dentes que não foram cimentados (n=8), foram aleatoriamente alocados de acordo a cada condição experimental e analisados por MEV após condicionamento. Os dados de RU e NI foram submetidos a ANOVA 3 fatores e teste de Tukey (α=0,05). O AMF apresentou valores de RU similares ao AOF independente do tempo e da viscosidade utilizada (p>0,001). O aumento do tempo, aumentou significativamente os valores de RU (p<0,001). AOF apresentou maiores valores de NI quando comparado com AMF (p<0,001). Quando foi comparada a viscosidade, independente do tipo de ácido utilizado, o ácido liquido aumentou significativamente a deposição de NI (p<0,05). O incremento do tempo de aplicação do AOF resultou em um significativo aumento de NI (p<0,01). O AMF 40% apresentou RU similar quando comparado ao AOF 37%, independente da viscosidade e tempo de aplicação com uma menor NI.
In-vitro evaluation the influence of the different conditioner times (7 and 15 seconds) of 40% meta-phosphoric acid (MPA) and 37% ortho-phosphoric acid (OPA) in different viscosities (gel and liquid) on the adhesive properties of the root interface. Seventy-two roots of human premolars were endodontically prepared and randomly assigned into the 8 experimental conditions (n = 9) according to the combination of the variables: Acid [37% ortho-phosphoric acid (OPA) and 40 meta-phosphoric acid (MPA)]; acid viscosity [(gel (G) and liquid (L)]; and application times (7 and 15 s). The adhesive system Ambar Universal was applied and the fiber post were cemented with dual cement Allcem Core. After cementation, the teeth were cross-sectioned into slices and subjected to the pushout bond strength test (BS) (n = 6) at a speed (0.5 mm/min). For the nanoleakage (NL) evaluation, slices was randomly selected from each group and were immersed in silver nitrate solution for analysis by Scanning Electron Microscopy (SEM). For morphological analysis of the root surface, the teeth that were not cemented (n = 8) were randomly allocated according to each experimental condition and analyzed by SEM after acid etching. Data from BS and NL were submitted to ANOVA 3 factors and Tukey's test ( = 0.05). MPA showed similar values of BS to OPA, regardless of the application time and viscosity used (p < 0.001). The increase of application time resulted in a statistically higher BS values (p < 0.001). OPA increased the values of NL when compared with MPA (p < 0.001). When the viscosity was compared, regardless of the acid used, the liquid acid promoted a significant increase in the silver nitrate. (p < 0.05). The increase of the time of application of the OPA resulted in a significant increase of NL (p < 0.01). The use of 40% MPA promoted a similar BS, regardless of the viscosity and application time with lower NL than the 37% OPA.
APA, Harvard, Vancouver, ISO, and other styles
42

Juškevičius, Kęstutis. "Plonųjų dielektrinių sluoksnių optinių ir fizinių savybių tyrimas bei jų formavimo technologijų optimizavimas." Doctoral thesis, Lithuanian Academic Libraries Network (LABT), 2014. http://vddb.library.lt/obj/LT-eLABa-0001:E.02~2014~D_20140912_140607-24032.

Full text
Abstract:
Disertacijos tikslas buvo nustatyti fizikines priežastis, ribojančias dielektrinių optinių dangų spektrinius parametrus bei jų atsparumą lazerio spinduliuotei ir pateikti įvairių jų gamybos etapų – optinių pagrindukų paruošimo dengimo procesui, optinių dangų struktūros bei dengimo technologijų optimizavimo rekomendacijas optinių komponentų gamintojams. Šiame darbe buvo atlikta komerciškai poliruotų kvarco pagrindukų visapusiška paviršiaus analize, kuri parodė, kad paviršiuje esama poliravimo medžiagų liekanų įstrigusių įvairiuose rėžiuose bei mikrotrūkiuose ir “paslėptų” po taip vadinamu Bilbio sluoksniu. Siekiant nuėsdinti šį sluoksnį ir pašalinti poliravimo medžiagų liekanas, buvo sukurta cheminio ėsdinimo HF/HNO3 tirpale metodika. Nustatyta, kad ėsdintų kvarco pagrindukų pažaidos lazerio spinduliuotei slenkstis padidėjo apie 4 kartus. Šiame darbe didelis dėmesys buvo skiriamas naujų optinių dangų modelių paieškai ir dangų formavimui, naudojant ZrO2/SiO2 medžiagų mišinius. Panaudojant metalų oksidų mišinių sluoksnius, buvo suformuotos didelio atsparumo skaidrinančios dangos ant netiesinių LBO kristalų bei didelio atspindžio periodiškai kintančio lūžio rodiklio optinės dangos ant kvarco pagrindukų. Šiame darbe buvo pasirinktas magnetroninio dulkinimo technologijos, kuri yra santykinai nauja optinių dangų industrijoje, optimizavimas. Pirma kartą pademonstruota reaktyvaus magnetroninio dulkinimo proceso valdymas, panaudojant kombinuotą reaktyviųjų dujų jutiklį. Jo pagalba buvo... [toliau žr. visą tekstą]
The main aim of this dissertation was to identify physical causes that limit optical component‘s spectral properties and resistance to laser radiation as well as to optimize the final substrate preparation procedure and coating deposition technology. In this work we report an experimental investigation of subsurface damage (SSD) in conventionally polished fused silica (FS) substrates, which are widely used in laser applications and directly influence performances of optical elements. Subsurface damages are defined as residual digs and scratches, some of which are filled with polishing slurry and covered with so-called Bielby layer (polished layer). Acid etching procedure of FS substrates was developed, which allows removing polished layer and eliminating SSD. Different durations of acid etching have been used to study laser induces damage threshold (LIDT) of FS substrates. These experiments revealed that the optimal etching time is ~1 min for a given acid concentration. LIDT of etched FS samples increased ~4 times. The LIDT in LiB3O5 (LBO) crystals coated with different types of (single AR@355 nm and triple AR@355+532+1064 nm wavelength) anti-reflective coatings was also investigated. All these coatings were produced of different oxide materials (ZrO2, Al2O3, and SiO2) and ZrO2-SiO2 mixtures by using the ion beam sputtering (IBS) deposition technique. Also, we present explorations of reactive magnetron sputtering technology for deposition of ZrO2 and Nb2O5/SiO2 mixture thin... [to full text]
APA, Harvard, Vancouver, ISO, and other styles
43

Juškevičius, Kęstutis. "Investigation of optical and physical properties of dielectric thin films and optimisation of their deposition technologies." Doctoral thesis, Lithuanian Academic Libraries Network (LABT), 2014. http://vddb.library.lt/obj/LT-eLABa-0001:E.02~2014~D_20140912_140620-35711.

Full text
Abstract:
The main aim of this dissertation was to identify physical causes that limit optical component‘s spectral properties and resistance to laser radiation as well as to optimize the final substrate preparation procedure and coating deposition technology. In this work we report an experimental investigation of subsurface damage (SSD) in conventionally polished fused silica (FS) substrates, which are widely used in laser applications and directly influence performances of optical elements. Subsurface damages are defined as residual digs and scratches, some of which are filled with polishing slurry and covered with so-called Bielby layer (polished layer). Acid etching procedure of FS substrates was developed, which allows removing polished layer and eliminating SSD. Different durations of acid etching have been used to study laser induces damage threshold (LIDT) of FS substrates. These experiments revealed that the optimal etching time is ~1 min for a given acid concentration. LIDT of etched FS samples increased ~4 times. The LIDT in LiB3O5 (LBO) crystals coated with different types of (single AR@355 nm and triple AR@355+532+1064 nm wavelength) anti-reflective coatings was also investigated. All these coatings were produced of different oxide materials (ZrO2, Al2O3, and SiO2) and ZrO2-SiO2 mixtures by using the ion beam sputtering (IBS) deposition technique. Also, we present explorations of reactive magnetron sputtering technology for deposition of ZrO2 and Nb2O5/SiO2 mixture thin... [to full text]
Disertacijos tikslas buvo nustatyti fizikines priežastis, ribojančias dielektrinių optinių dangų spektrinius parametrus bei jų atsparumą lazerio spinduliuotei ir pateikti įvairių jų gamybos etapų – optinių pagrindukų paruošimo dengimo procesui, optinių dangų struktūros bei dengimo technologijų optimizavimo rekomendacijas optinių komponentų gamintojams. Šiame darbe buvo atlikta komerciškai poliruotų kvarco pagrindukų visapusiška paviršiaus analize, kuri parodė, kad paviršiuje esama poliravimo medžiagų liekanų įstrigusių įvairiuose rėžiuose bei mikrotrūkiuose ir “paslėptų” po taip vadinamu Bilbio sluoksniu. Siekiant nuėsdinti šį sluoksnį ir pašalinti poliravimo medžiagų liekanas, buvo sukurta cheminio ėsdinimo HF/HNO3 tirpale metodika. Nustatyta, kad ėsdintų kvarco pagrindukų pažaidos lazerio spinduliuotei slenkstis padidėjo apie 4 kartus. Šiame darbe didelis dėmesys buvo skiriamas naujų optinių dangų modelių paieškai ir dangų formavimui, naudojant ZrO2/SiO2 medžiagų mišinius. Panaudojant metalų oksidų mišinių sluoksnius, buvo suformuotos didelio atsparumo skaidrinančios dangos ant netiesinių LBO kristalų bei didelio atspindžio periodiškai kintančio lūžio rodiklio optinės dangos ant kvarco pagrindukų. Šiame darbe buvo pasirinktas magnetroninio dulkinimo technologijos, kuri yra santykinai nauja optinių dangų industrijoje, optimizavimas. Pirma kartą pademonstruota reaktyvaus magnetroninio dulkinimo proceso valdymas, panaudojant kombinuotą reaktyviųjų dujų jutiklį. Jo pagalba buvo... [toliau žr. visą tekstą]
APA, Harvard, Vancouver, ISO, and other styles
44

Scholz, Maria Fernanda Costa. "Influência do modo de aplicação e viscosidade do ácido fosfórico 37% na adesão de pinos de fibra de vidro em condutos radiculares." Universidade Estadual de Ponta Grossa, 2018. http://tede2.uepg.br/jspui/handle/prefix/2587.

Full text
Abstract:
Submitted by Angela Maria de Oliveira (amolivei@uepg.br) on 2018-07-31T17:05:16Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Maria Fernanda Costa Scholz.pdf: 1290758 bytes, checksum: ddb5c2c0ca43f593268a067c13b5296b (MD5)
Made available in DSpace on 2018-07-31T17:05:16Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Maria Fernanda Costa Scholz.pdf: 1290758 bytes, checksum: ddb5c2c0ca43f593268a067c13b5296b (MD5) Previous issue date: 2018-02-23
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
O objetivo do presente estudo foi avaliar a influência da viscosidade do ácido fosfórico e do modo de aplicação nos valores de resistência de união de pino de fibra de vidro cimentados na dentina radicular através do teste de pushout. Raízes de 32 pré-molares foram preparadas endodonticamente e divididas em 4 grupos (n = 8) de acordo com a combinação dos seguintes fatores: viscosidade do ácido e forma de aplicação. Após aplicação do adesivo Universal no interior dos condutos, foram realizadas as cimentações dos pinos com o cimento resinoso RelyX ARC. Em seguida, as raízes foram seccionadas transversalmente em 6 fatias de aproximadamente 1 mm e o teste de push-out foi realizado a uma velocidade de 0,5 mm/min. Os resultados de resistência de união foram submetidos a uma análise de variância de três fatores de medidas repetidas e teste de Tukey (alpha = 0.05). A interação dupla modo de aplicação vs. viscosidade do ácido (p = 0,0002) e o terço radicular (p < 0,0001) foram estatisticamente significantes. O maior valor de resistência de união foi observado no grupo condicionado com ácido fosfórico líquido sob o modo de aplicação sônica (p < 0,05) sendo todos os outros grupos semelhantes entre si. Quanto ao terço radicular, observou-se maior valor de resistência de união no terço cervical, seguido do terço médio e do terço apical terço apical (p < 0,05). Pelos resultados pode-se concluir que uma melhor adesão de pinos de fibra de vidro ao conduto radicular pode ser obtida através do condicionamento com ácido fosfórico líquido com aplicação sônica.
The aim of the present study was to evaluate the influence of the etchant viscosity (liquid or gel) and the application mode (passive or sonic) on the pushout bond strength values of fiberglass post to root dentin and the conditioning pattern on the smear-layer covered root dentin before cementation. The roots of premolars were prepared endodontically and divided into 4 groups (n = 8) according to the combination of the main factors: phosphoric acid viscosity (liquid gel) and application mode (passive or sonic). After the application of the universal adhesive into the root canals, the fiberglass posts were cemented with cementation system RelyX ARC. Then, the roots were sectioned transversely 6 slices of approximately 1 mm and the push-out test performed at a speed 0.5 mm/min. The results were submitted to a repeated measures three-way ANOVA and Tukey’s test (alpha = 0.05). The cross-product interaction mode of application vs. etchant viscosity (p = 0.0002) and the main factor root third (p < 0.0001) were statistically significant. The highest bond strength value was observed when the conditioning of the root canal was performed with a liquid phosphoric acid under sonic application mode (p < 0.05), being all other groups similar one another (p < 0.05). Regarding the root third, the highest push-out bond strength value was observed in the cervical third, followed by the medium third and the apical thirds (p < 0,05). The most common fracture pattern was the mixed failure. By the partial results one may conclude that a better bonding of fiberglass posts to root canals can be achieved when the conduits are conditioned with a
APA, Harvard, Vancouver, ISO, and other styles
45

Salas, Mabel Miluska Suca. "Influência da viscosidade do condicionador ácido na dentina radicular sobre a resistência de união de um sistema de cimentação adesivo. Avaliação por teste de push-out e MEV." Universidade Federal de Pelotas, 2005. http://repositorio.ufpel.edu.br/handle/ri/2308.

Full text
Abstract:
Made available in DSpace on 2014-08-20T14:30:20Z (GMT). No. of bitstreams: 1 Mabel Salas_DISSERTACAO.pdf: 6552657 bytes, checksum: 11efe494170784ff76d8fc2f0dff8e56 (MD5) Previous issue date: 2005-06-10
Actually different alternatives to restored teeth with endodontical treatment are propose, otherwise with the advented of adhesive systems their use as luting endodontical cements and bonding resin cement for fiber posts are common. However the inherent characteristics behavior of these materials and the different variances presented at root canal, turns them sensible to failure. The aime of the study was to evaluated: a) the influence of two luting cements: containing eugenol (Endofill) and containing resin materials (Ahplus) on dentin bonding strength using push-out test at cervical, medium and apical root dentin regions, using two different 37% phosphoric acid viscosities: gel and liquid: b) the effect of the total-etching acid process on the pattern observed of the conditioned dentine substrate, c) Characterize the dentinal surface at different root regions d) Classify the fracture patterns between the substrate and the resin cement at three root regions. One hundred and four uniradicular teeth without caries lesions, extracted by orthodontics or periodontal reasons, with 7mm of diameter and 14mm of length were selected, disinfected in 0,5% chloramine and storage in distillated water at 5ºC. Endodontical canal treatments were performed using the Step-back technique and obturated with Endofill and AHplus. The preparation of the post space was 11mm depth using standardized rotary instruments. The total-etching with the gel and liquid acid were performed. The fiber posts were marked at the same depth, cuted, dry and silanized. Then two coats of Prime&bond 2,1 previously mixed with the self-cure activator, were applied at the post surface and into de root canal, after 1 minute the post were photocured (halogen light intensity of 450mW). The resin cement was mixed and placed into de canal using a lentuloespiral instrument. The posts were placed and a static force of 5kg for 10 minutes were applied, after words both adhesive and cement were photocured for 40 seconds, storage for 24 h in 37ºC, and embedded in a poliestyren resin. Cross-sectional cuts were obtained for the push-out test. The test were performed at a crosshead speed of 0,5mm/min, and a plane 20 cylindrical point was applied at the post centre. The maxim load was calculated in Mpa. The adhesive area was calculated using a tapered-cone shaped formula. The results were subjected to statistical analysis using a ANOVA test for multiple variables and a Pos Doc test(p<0,05) Statistically significant differences were detected between all the evaluated criterias: acids, cements and regions, and when they were inter-relationated between them. It was concluded that the use of 37% of phosphoric acid in a liquid form, allows a better penetration into the root canal, a uniform decalcification, consequently enhancing the bonding strength of the root dentine, particularly at apical region.
Actualmente diversos tipos de alternativas para restaurar dentes submetidos a tratamento endodontico são propostos, dentre estes, sistemas adesivos resinosos cimentantes para uso endodontico e pinos de fibra. No entanto as carateristicas inerentes apresentadas por estes materiais e as diversas variáveis presentes em nível radicular os fazem sensíveis a falhas. O objetivo deste trabalho foi avaliar a influência do tipo de cimento endodôntico e da viscosidade do ácido sobre a resistência de união de um sistema adesivo utilizando pinos de fibra de vidro, mediante o teste push-out e MEV em três níveis radiculares: cervical, médio e apical. Foram selecionados 104 dentes uniradiculares sem cárie, extraídos por motivos periodontais ou ortodônticos. Os dentes foram desinfectados em cloramina 0,5% e armazenados em água destilada a 5ºC. Os tratamentos endodônticos foram padronizados com a técnica step-back, obturando-se com Ahplus ou com Endofill. Os preparos para os pinos foram de 11mm padronizando os instrumentos. O condicionamento com o ácido fosfórico a 37%, em gel ou em líquido, foi realizado em ambos grupos. Os pinos de vidro foram seccionados em 11 mm,, silanizados, cobertos com duas camadas de Prime&bond 2.1 misturado previamente com o ativador de autopolimerização. O cimento resinoso Enforce (Dentsply) foi misturado e aplicado no canal utilizando lentulo. O pino era inserido e aplicava-se uma força padronizada de 5kg durante 10 min e sendo polimerizados por 40 seg, e armazenados por 24 horas a 37ºC, incluídos em resina de polietileno, cortados em 6 discos transversais de 1,5mm e lixados. O teste de push-out foi com uma velocidade de 0,5 mm/min, a ponta ativa cilíndrica plana (0,9 mm de diâmetro) era aplicada no centro do pino. A carga máxima foi convertida em MPa.. As diferenças entre os grupos foram determinadas mediante a análise de variância de ANOVA de três critérios, teste de Post Hoc (p<0,05). De acordo com a análise de fratura foram observadas diferenças nos três terços estudados particularmente no terço apical. Segundo a análise de fratura, foram observados quatro padrões diferentes de fraturas. Todas as variáveis testadas influenciaram significativamente a 18 resistência de união. A região cervical produziu geralmente menores valores de união, quando era utilizado o ácido em gel. Por outro lado, quando era utilizado o ácido em líquido os valores de resistência aumentavam, podendo-se concluir que a utilização de ácido fosfórico 37% em líquido permite uma maior penetração do adesivo no canal radicular produzindo um aumento da resistência de união na dentina radicular, particularmente no terço apical.
APA, Harvard, Vancouver, ISO, and other styles
46

Szesz, Anna Luiza. "Efeito do condicionamento do esmalte previamente a aplicação de sistemas adesivos autocondicionantes em restaurações de lesões cervicais não-cariosas: revisão sistemática e meta-análise." Universidade Estadual de Ponta Grossa, 2017. http://tede2.uepg.br/jspui/handle/prefix/2353.

Full text
Abstract:
Submitted by Angela Maria de Oliveira (amolivei@uepg.br) on 2017-09-06T16:18:49Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) ANNA_LUIZA_SZESZ.pdf: 1800626 bytes, checksum: 05a915ed2eba46109040f4ee4162b620 (MD5)
Made available in DSpace on 2017-09-06T16:18:49Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) ANNA_LUIZA_SZESZ.pdf: 1800626 bytes, checksum: 05a915ed2eba46109040f4ee4162b620 (MD5) Previous issue date: 2017-08-14
O objetivo desse estudo foi identificar por meio de revisão sistemática e meta-análise se o condicionamento seletivo do esmalte antes da aplicação de sistemas adesivos autocondicionantes, melhora as taxas de retenção, descoloração e adaptação marginal de restaurações cervicais não-cariosas (LCNC) em pacientes adultos. As seguintes bases de dados foram pesquisadas MEDLINE, Scopus, Web of Science, LILACS, BBO Biblioteca, Biblioteca Cochrane e SIGLE, sem restrições, bem como os resumos da conferência anual da IADR, além do registro de ensaios clínicos. Dissertações e teses também foram pesquisados utilizando os bancos de dados da ProQuest e Periódicos Capes. Foram incluídos ensaios clínicos randomizados que compararam a eficácia clínica dos adesivos autocondicionantes com e sem condicionamento seletivo do esmalte usado para restaurações diretas de resina composta em LCNC na dentição permanente. Para avaliação da qualidade dos estudos foi utilizado a ferramenta risco de viés da colaboração Cochrane. Após a remoção das duplicatas, foram identificados 2689 artigos. Após triagem foram mantidos 10 estudos na síntese qualitativa. Sete foram considerados de baixo risco de viés. O tempo de avaliação dos estudos variaram entre 1 a 5 anos. Com exceção de um ano de acompanhamento, houve descoloração e desadaptação marginal significativamente menor durante todo o tempo de acompanhamento. Além disso, foi observada perda significativamente menor da retenção para as restaurações com 3 anos de acompanhamento para o grupo que utilizou o condicionamento seletivo do esmalte. O condicionamento seletivo do esmalte, antes da aplicação de sistemas adesivos autocondicionantes em LCNC, pode melhorar o desempenho clínico de restaurações em resina composta, em até 5 anos de acompanhamento.
The objective of this study was to identify through a systematic review and metaanalysis if selective etching of enamel margins, prior to the application of self-etching adhesive systems, improves the retention rates marginal discoloration and marginal adaptation of cervical composite restorations in non-carious cervical lesions (NCCLs) of adult patients. The following databases were searched for MEDLINE, Scopus, Web of Science, LILACS, BBO Library, Cochrane Library and SIGLE were searched without restrictions, as well as IADR abstracts and gray literature via trial registries. Dissertations and theses were searched using the ProQuest Dissertations and Periodical Capes. Randomized clinical trials comparing the clinical efficacy of selfetching adhesives with and without selective enamel etching used for direct composite resin restorations on NCCLs in the permanent dentition were included. For evaluate the quality of the studies, the bias risk tool Cochrane Collaboration, was used. After removal of duplicates, 2689 articles were identified. Following screening of abstracts, 10 studies remained in the qualitative synthesis. Seven were considered to be at “low” risk of bias. The report of the studies varied from 1 to 5 years. Except for one-year follow-up, there was a significantly lower marginal discoloration and adaptation during all follow-up periods. In addition, a significantly lower loss of retention was observed for the 3-year follow-up restorations for the group that used selective enamel conditioning. Selective enamel prior to application of self-etch adhesive systems in NCCLs might improve clinical performance of resin-composite cervical restorations, in up to 5 years of follow-up.
APA, Harvard, Vancouver, ISO, and other styles
47

Tachibana, Arlene. "Influência da contaminação com sangue e de diferentes agentes de limpeza na adesão de um sistema autocondicionante aos tecidos dentais." Universidade de São Paulo, 2008. http://www.teses.usp.br/teses/disponiveis/23/23134/tde-21012009-142856/.

Full text
Abstract:
A presença de lesões de cárie localizadas em áreas de difícil acesso para realização de isolamento absoluto torna a contaminação do campo operatório um fator de grande importância para o sucesso de uma restauração adesiva, apesar da grande variedade de sistemas adesivos de uso simplificado existentes atualmente no mercado odontológico. Os estudos que envolvem contaminação por sangue existentes na literatura expõem diferentes métodos de manipulação do contaminante, quanto a adição ou não de um anticoagulante bem como quanto a possibilidade de armazenamento deste. Este trabalho teve como objetivo avaliar, através do ensaio de microcisalhamento, a metodologia mais adequada para obtenção, manipulação do sangue e a eficiência de diferentes substâncias de uso corrente no consultório odontológico para remoção do contaminante de uma superfície dental. No experimento 1 deste trabalho, 6 dentes foram seccionados ao meio, no sentido do longo eixo e distribuídos em grupos, de acordo com o período de armazenamento do sangue heparinizado (0 hora, 24 horas, 7 dias) utilizado para contaminá-los previamente a aplicação do sistema adesivo autocondicionante de passo único (Clearfill S3 Bond). No expermiento 2, 18 dentes foram seccionados da mesma forma e distribuídos em grupos de acordo com o contaminante utilizado (ausência de contaminante, sangue fresco e sangue heparinizado-este utilizado pelo período máximo de tempo determinado pelo experimento anterior). No experimento 3 deste trabalho, 39 dentes foram seccionados e distribuídos em grupos de acordo com o agente de limpeza utilizado para remoção do contaminante (água oxigenada, Dakin e tergentol). Nesta fase foi avaliada a eficiência dos agentes de limpeza na restauração dos valores de adesão dos tecidos dentais aos valores obtidos em condições sem contaminação. Em todos os experimentos, inicialmente foram realizados os testes em esmalte e em seguida os dentes foram desgastados para realização dos testes em dentina, nas mesmas condições. Após a realização dos testes de microcisalhamento, observamos os tipos de fraturas ocorridas e as médias dos valores de resistência adesiva obtidos por cada metade de dente calculada. Os resultados obtidos nos permitiram concluir que o sangue heparinizado pode ser armazenado para posterior utilização por até 7 dias sem perder suas características de contaminante. A escolha relativa ao tipo de sangue que se deve utilizar - sangue fresco ou sangue heparinizado fica a critério do pesquisador e suas conveniências experimentais. Todas as substâncias testadas como agente de limpeza (líquido de Dakin, Tergentol e água oxigenada) na remoção do contaminante sobre esmalte e dentina foram eficientes para restabelecer os valores de resistência de união do sistema adesivo autocondicionante de passo único. Adicionalmente, a simples aplicação do jato de água sobre a superfície de esmalte e dentina contaminada é suficiente para a recuperação dos valores de resistência adesiva.
Although new self-etching adhesive systems provide a faster application due to a reduced number of components and application steps, the risk of contamination by oral fluids is not eliminated. Achieving good moisture control is a common problem in restorative dentistry. Blood contamination can occur especially when rubber dam isolation is not feasible, like carious lesions found near to gingival margin. To simulate gingival bleeding in laboratory study, some investigators have used freshly capillary blood, on the other hand other investigators have used venous blood sample with an anticoagulant. Among the studies that used venous blood with anticoagulant, some authors used this blood immediately after. However, other authors used the collected blood sample within one week. Based on this variety of blood manipulation, the aim of the present study was to investigate, in the first phase, the influence of storage period of the heparinized blood on microshear bond strength of a 1-step self-etching adhesive system to enamel and dentin. In second phase, the influence of heparinized venous blood vs. fresh capillary blood on microshear bond strength of a 1-step self-etching adhesive system to enamel and dentin was tested. In the third phase of this study the efficiency of different cleaning agents (Dakins solution, Tergentol and Hidrogen peroxide) on microshear bond strength of a 1-step self-etching adhesive system to enamel and dentin contaminated by blood was investigated. The results show that heparinized blood can be used to simulate gingival bleeding in laboratory study for up to 7 days without difference in its deleterious influence on adhesion tests. Contamination with fresh blood or heparinized blood resulted in lower values of adhesion, compared to enamel and dentin without contamination. All cleaning agents used in this study were efficient to recover the lost microshear bond strengths of blood contaminated enamel and dentin.
APA, Harvard, Vancouver, ISO, and other styles
48

Vellame, Igor Alencar 1984. "Traços de íons em apatita = ataque químico, tratamento térmico e modelagem." [s.n.], 2012. http://repositorio.unicamp.br/jspui/handle/REPOSIP/277143.

Full text
Abstract:
Orientadores: Sandro Guedes de Oliveira, Julio Cesar Hadler Neto
Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Física Gleb Wataghin
Made available in DSpace on 2018-08-21T04:43:57Z (GMT). No. of bitstreams: 1 Vellame_IgorAlencar_D.pdf: 6307121 bytes, checksum: 509c7cc3c5c11f238463340fa191af50 (MD5) Previous issue date: 2012
Resumo: O presente trabalho pode ser inserido na grande área de estudo da interação da radiação com sólidos. Ele tem como principal objetivo entender a cinética de reconstituição dos danos causados por irradiação com íons ( traço latente) na apatita e e realizado através do estudo de annealing em traços atacados. O que se denomina traço latente e a trilha de danos causada pela desaceleração do íon, enquanto este atravessa a matéria. Estes traços latentes são meta-estaveis em relação ao tratamento térmico e apresentam uma taxa de reação a dissolução muito mais elevada que o mineral não danificado. Assim, para compreender as alterações causadas pelos tratamentos térmicos e necessária entender como o processo de ataque químico ocorre. Um cristal natural de apatita foi cortado em algumas orientações cristalográficas (principalmente basal e prismática) e estas amostras foram montadas em resina para obtenção de uma superfície plana com técnicas de polimento. Grande parte destas amostras foi irradiada com nêutrons (para induzir a fissão do isótopo 235 U com fluências de nêutrons térmicos próximas a 3xl015 cm-2 ) ou com íons pesados (152Sm e 238 U com fluências pr6ximas a lx106 cm-2 e 5x 1011 cm-2). Utilizando a espectroscopia no infra-vermelho, foi possível estimar o valor do diâmetro do traço latente. Os valores encontrados (~8-9 nm) são coerentes com diversas medidas utilizando outras técnicas presentes na literatura. As taxas de dissolução da superfície do material pelo acido nítrico em diferentes condições (concentração e temperatura) foram medidas pelo método da máscara com êxito. Observou-se uma inversão na razão entre as taxas para as diferentes orientações conforme a concentração do reagente aumentada. A distribuição de comprimentos projetados também foi estudada para estimar a eficiência de observação e revelação do ataque químico (razão entre quantos traços são efetivamente contados e quantos traços são gerados). A metodologia presente na literatura para o calculo da distribuição de comprimentos projetados foi revista e novas estimativas foram feitas utilizando métodos numéricos com intuito de estimar os comprimentos e desvios dos fragmentos de fissão leve e pesado na apatita. Foi observada uma deficiência intrínseca na medida do comprimento projetado, mas esta sozinha não e capaz de explicar o deficit de alcance observado para as irradiações com íons. Duas metodologias para o ca1culo do conteúdo de urânio nas amostras são apresentadas e os resultados da comparação com valores obtidos par outras técnicas independentes são satisfatórios. Isto fortalece o método dos traços de fissão como uma técnica absoluta para a dosimetria de nêutrons. Par fim, para o estudo do tratamento térmico, dais conjuntos de dados pana traços de íons foram preparados: um a partir da diminuição do comprimento projetado; e outro com o estudo da variação na abertura superficial de traços de íons incidentes perpendicularmente. Foi possível correlacionar as reduções da abertura superficial e do comprimento através de uma lei de potencia. Aparentemente, a abertura superficial parece ser um indicador da quantidade de defeitos e isto possibilita vincular melhor a cinética do tratamento térmico. Algumas extrapolações geológicas também foram realizadas e o razoável acordo com os dados geológicos demonstra que o processo e universal e que traços de íons podem ser usados como ferramenta para o estudo do tratamento térmico em traços atacados
Abstract: This work can be inserted in the great study area of radiation interactions with solids. It has as the main goal the understanding of the reconstitution of damage caused by ion irradiation (latent track) in apatite and it is investigated through the annealing of chemically etched tracks. A latent track is the damage trail caused by the ion deceleration in matter. These tracks are thermally meta-stable and they present an enhanced dissolution rate when compared to the non-damaged bulk mineral. Thus, in order to understand t he alterations caused by a thermal treatment, it is necessary to understand how does the chemical etching occur. A natural apatite crystal was cut in some crystallographic orientations (mainly basal and prismatic) and these samples were mounted in epoxy resin in order to obtain a fiat surface with polishing techniques. Great part of these samples were irradiated with thermal neutrons (inducing the 235 U fission with fiuence close to 3x 1015 cm-2 ) or heavy ions e 52Sm and 238U with nominal fluences of lx106 cm-2 and 5x1011 cm-2 ). Applying infra-red spectroscopy, it was possible to estimate the values of ion latent track diameters. The founded values (~8-9 nm) are coherent with several measurements employing other techniques presented in the literature. The mineral surface dissolution rates by nitric acid were successfully measured in different conditions ( etchant concentration and temperature) with the mask method. As the etchant concentration increases, an inversion in the dissolution rates ratio between different orientations was observed. The projected length distribution was also studied to estimate the revelation/observation efficiency (ratio between how many tracks were effectively counted and how many are expected). The methodology presented in the literature for the calculation of the expected projected length distribution was revised and new estimates were made with numerical methods. These numerical methods were employed to estimate the length and standard deviation of light and heavy fission fragments in apatite. An intrinsic deficit in the projected length measurement was observed. However, it alone could not explain the huge range deficit observed for external source irradiation in apatite. Two methodologies for the calculation of uranium content in t he samples were proposed. The comparison of the results with other values found from independent techniques was satisfactory. This strengthen the fission track method as an absolute technique for neutron dosimeter. Finally, two data sets for ion track thermal annealing study were prepared:! one from the shortening of projected length; and the other from the variation of perpendicular ion track etch-pit aperture. It was possible to correlate the aperture and length reduction with a power law. Apparently, the etch-pit aperture seems to be an indicator of the amount of defects which remains in the latent track after the thermal treatment. This enables one to better constrain the thermal annealing kinetic. Some geological extrapolation were also predicted. The reasonable agreement with geological data demonstrates that the process is universal and that ion tracks can be used as proxies for the thermal annealing behavior study
Doutorado
Física
Doutor em Ciências
APA, Harvard, Vancouver, ISO, and other styles
49

Chou, Qiong-Ru, and 周瓊茹. "Fabrication of deep sub-micrometer silicon cylinder array using e-beam lithography and reactive ion etching." Thesis, 2006. http://ndltd.ncl.edu.tw/handle/00880349585709860408.

Full text
Abstract:
碩士
國立中正大學
物理所
94
In electron beam lithography, the matter wave length of electron, which be added 20 keV voltage, is pproximately 10-11m. The wave length is smaller than 193 nm or 157 nm that the Optical lithography excimer laser wave length has. In general, the electron beam lithography has the very good ability of high resolution, and the resolution can reach several nm degree(ignoring exposure depth).The electron beam lithography can be used in photo masks fabrication, direct e-bean writing, and nanometer structures fabrication. In our article, we try to fabricate high aspect ratio 2-D cylinder array structure. The desire of diameter is smaller than 150 nm, height is higher than 2 mm, and the lattice const is 300 nm. We want to use e-bean lithography and reactive ion etching (RIE) to fabricate the desired size. We must make up the etching mask, then try the RIE parameter. We try the positive and negative photo resist at the same time in order to choosing the best method. The changes of RIE parameters will make the change in the etching structures and height. We try to change the etching time, power, pressure and ratio of the gas, and compare the RIE result. In this way, we want to get the best RIE parameters for helping us to fabricate the desired structures.
APA, Harvard, Vancouver, ISO, and other styles
50

Hsieh, Yi-Ta, and 謝易達. "Low energy e-beam irradiated alkanethiolate SAMs chemically-adsorbed on Au for anti-etching resist of lithography." Thesis, 2007. http://ndltd.ncl.edu.tw/handle/24738697756106881146.

Full text
Abstract:
碩士
國立成功大學
材料科學及工程學系碩博士班
95
Alkanethiol self-assembled monolayers (AT-SAMs) have good resistance for specific wet-etching solutions and behave as negative/positive resists after irradiated by physical sources such as X-ray, ion beams, and electron beam. The aim of this study is to fabricate gold pattern via the low energy (E<1 keV) electron beam lithography (LE-EBL) followed by exposing to air, then developing with gold-etching solutions for octadecanethiol (ODT) on the substrate. The substrate is prepared by first electron-beam evaporating a thickness of 5 nm titanium on the silicon wafer, and followed evaporating 50 nm thickness of gold on the titanium layer. Subsequently, immersing of the gold substrate and ODT/Au samples into the gold-etching solution in order to find out the end time point of gold layer of which, leading to understanding of the resistivity of ODT/Au in the etching solution. Also, the process doses of LE-EBL are determined from the dose-static contact angle relation, followed by HRXPS analysis. Finally, the gold patterns are obtained by gold-etching solution development. Concluded from the analyses of negative-positive resist transformation, the experimental procedure of ODT/Au was first irradiated by 50eV LE-EBL with three specific doses, after that proceeded to exposed to air. With the dose of 7.04 mC/cm2, ODT/Au will become a more strengthened structure and then form a negative resist in the correlation with cross-linking from alkyl matrix, partial breakdown of S-Au bonding and surface adsorption by air-borne species. Thus, it can obtain a gold pattern via gold-etching process. Besides, as a result of massive breakdown of alkyl matrix and S-Au bonding from ODT/Au under irradiation with doses of 64.06 and 128.13 mC/cm2, ODT SAMs would form a loose-packed structure on the gold substrate. The ODT/Au becomes less resistive for gold-etching and a positive gold pattern would form after gold-etching. By controlling LE-EBL doses and being exposed to air at the following step, ODT/Au could behave either as negative or positive resists. Finally, it will perform the negative and positive gold patterns after gold-etching process.
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!

To the bibliography