To see the other types of publications on this topic, follow the link: ECLIA.

Journal articles on the topic 'ECLIA'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 50 journal articles for your research on the topic 'ECLIA.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse journal articles on a wide variety of disciplines and organise your bibliography correctly.

1

Chang, Le, Junpeng Zhao, Fei Guo, et al. "Comparative Evaluation and Measure of Accuracy of ELISAs, CLIAs, and ECLIAs for the Detection of HIV Infection among Blood Donors in China." Canadian Journal of Infectious Diseases and Medical Microbiology 2020 (August 14, 2020): 1–9. http://dx.doi.org/10.1155/2020/2164685.

Full text
Abstract:
Background. Enzyme-linked immunosorbent assay (ELISA) is the only serological method approved for blood screening in China. Automated chemiluminescence immunoassay (CLIA) and electrochemiluminescence immunoassay (ECLIA) had been used in clinical laboratories but not applied to screen HIV among blood donors. This study aimed to evaluate the performance of ELISA, CLIA, and ECLIA, focusing on the feasibility of CLIA/ECLIA for blood screening. Method. 1029 blood donations from 14 blood centers screened by ELISA were enrolled in the study. All plasma samples were tested by eight ELISA assays in 16
APA, Harvard, Vancouver, ISO, and other styles
2

Yang, Yuanqing, Taiqing Zheng, Hongmin Jiang, Aiguo Tang, and Zhongyuan Xiang. "Reference intervals for serum progastrin-releasing peptide in healthy Chinese adults with electrochemiluminescence immunoassay." International Journal of Biological Markers 33, no. 4 (2018): 482–86. http://dx.doi.org/10.1177/1724600818776828.

Full text
Abstract:
Background: Reliable reference intervals for serum progastrin-releasing peptide (ProGRP) in healthy Chinese adults with electrochemiluminescence immunoassay (ECLIA) are still lacking in the Chinese population. Objectives: The study aims to establish reference intervals for ProGRP with ECLIA in apparently healthy Chinese adults. Methods: A total of 384 apparently healthy individuals from six representative geographical regions in China were enrolled: 200 males and 184 females with a mean age of 43.4±12.2 years, and an age range from 21 to 85 years. Serum ProGRP levels were analyzed on Cobas e60
APA, Harvard, Vancouver, ISO, and other styles
3

Jamal M. S. Al-khulidi, Mohammed A. Al-Taj, and Ashwaq Ahmed Abdullah. "Serocomparison between Electrochemiluminescence Immunoassay and Enzyme-Linked Immunosorbent Assays for detection HBsAg and total HBcAb among blood donors at National Blood Transfusion and Research Center- Taiz Branch, Taiz, Yemen." World Journal of Advanced Research and Reviews 20, no. 2 (2023): 066–70. http://dx.doi.org/10.30574/wjarr.2023.20.2.1823.

Full text
Abstract:
Hepatitis B virus (HBV) is a small, circular, partial double stranded DNA virus classified under hepadnaviridae. Almost more than 350 million HBV infected persons were reported universally. Blood/its product transfusion represents one of the commonly routes of HBV transmission that may increase the HBV infection globally. HBV is diagnosed routinely by detection of both HBV specific antigens (HBsAg, HBcAg, HBeAg) and antibody markers (HBcAb). ELISA and Electrochemiluminescent immunoassay (ECLIA) are the most common methods to detect HBV antigens or antibodies. This study aimed to compare betwee
APA, Harvard, Vancouver, ISO, and other styles
4

Jamal, M. S. Al-khulidi, A. Al-Taj Mohammed, and Ahmed Abdullah Ashwaq. "Serocomparison between Electrochemiluminescence Immunoassay and Enzyme-Linked Immunosorbent Assays for detection HBsAg and total HBcAb among blood donors at National Blood Transfusion and Research Center- Taiz Branch, Taiz, Yemen." World Journal of Advanced Research and Reviews 20, no. 2 (2023): 066–70. https://doi.org/10.5281/zenodo.12568415.

Full text
Abstract:
Hepatitis B virus (HBV) is a small, circular, partial double stranded DNA virus classified under&nbsp;<em>hepadnaviridae</em>.&nbsp; Almost more than 350 million HBV infected persons were reported universally. Blood/its product transfusion represents one of the commonly routes of HBV transmission that may increase the HBV infection globally. HBV is diagnosed routinely by detection of both HBV specific antigens (HBsAg, HBcAg, HBeAg) and antibody markers (HBcAb). ELISA and Electrochemiluminescent immunoassay (ECLIA) are the most common methods to detect HBV antigens or antibodies.&nbsp; This stu
APA, Harvard, Vancouver, ISO, and other styles
5

Dildar, Shabnam, Asma Danish, Mehjabeen Imam, Arshi Naz, and Tahir Sultan Shamsi. "Diagnostic Performance of Three Serological Assays for Anti-SARS-CoV-2 Antibody Detection." National Journal of Health Sciences 5, no. 4 (2021): 162–65. http://dx.doi.org/10.21089/njhs.54.0162.

Full text
Abstract:
Abstract: Objective: To evaluate the diagnostic performance of Electrochemiluminescence (ECLIA) enzyme linked immunosorbent (ELISA) and lateral flow Immunofluorescence (LFIA) for anti-SARS-COV-2 antibody detection. Materials and Methods: Sensitivity was calculated with convalescent plasma (CP) donor’s samples. Specificity was checked by using pre-pandemic October 2019 samples. All samples were tested for anti-SARS-COV-2 antibody by using Electrochemiluminescence (ECLIA), Enzyme Linked Immunosorbent Assay (ELISA) and Lateral flow Immunofluorescence (LFIA) assay. Results: Total 55 patients were
APA, Harvard, Vancouver, ISO, and other styles
6

Sarić-Matutinović, Marija, Tanja Diana, Biljana Nedeljković-Beleslin, et al. "Sensitivity of three thyrotropin receptor antibody assays in thyroid-associated orbitopathy." Journal of Medical Biochemistry 41, no. 2 (2022): 211–20. http://dx.doi.org/10.5937/jomb0-34718.

Full text
Abstract:
Background: Thyrotropin receptor autoantibodies (TSH-RAb) are indispensable biomarkers in the laboratory assessment of thyroid-associated orbitopathy (TAO). Clinical sensitivity of three different assays for TSH-R-Ab determination was evaluated in patients with TAO. Methods: 87 consecutive TAO patients were enrolled and their serum samples analyzed in parallel with three assays. An ECLIA competitive binding and a chemiluminescent bridge immunoassay were used to measure total and binding TSH-R-Ab concentration, while their functional activity was determined using a stimulatory TSH-R-Ab (TSAb) c
APA, Harvard, Vancouver, ISO, and other styles
7

Rahmawati, Isnaini, Irkham Irkham, Rahmat Wibowo, Jarnuzi Gunlazuardi, Yasuaki Einaga, and Tribidasari Anggraningrum Ivandini. "Electrogenerated Chemiluminescence for Immunoassay Applications." Indonesian Journal of Chemistry 21, no. 6 (2021): 1599. http://dx.doi.org/10.22146/ijc.64596.

Full text
Abstract:
Electrogenerated chemiluminescence (ECL) has recently become one of the most prominent and well-established transducers for immunoassay techniques. ECL relates a luminophore concentration in solution with the emission of light triggered by an electrochemical stimulus. ECL immunoassay (ECLIA) performance depends on the parameters of its light generation, including the luminophore, the species that emit light called labels in ECLIA; co-reactants, which are added reagents that support the luminophore to undergo the excited state; electrodes, which are the place for the ECL reactions to take place
APA, Harvard, Vancouver, ISO, and other styles
8

Lian, Yifei, Hongran Fu, Xiaoyi Xu, and Chuanyu Ju. "Application Effect and Accuracy Analysis of Electrochemiluminescence Immunoassay and Enzyme-Linked Immunosorbent Assay in the Serological Test of Hepatitis B Virus." Evidence-Based Complementary and Alternative Medicine 2022 (August 4, 2022): 1–7. http://dx.doi.org/10.1155/2022/9371497.

Full text
Abstract:
Objective. To explore the validity and accuracy of electrochemiluminescence immunoassay (ECLIA) and enzyme-linked immunosorbent assay (ELISA) in the serological detection of the hepatitis B virus. Methods. From 6 February 2019 to 1 March 2020, 96 patients diagnosed with hepatitis B virus infection in our hospital were recruited and assigned at a ratio of 1 : 1 to experimental groups A (GA) and B (GB), with 48 cases in each group, and the five major serological indicators of hepatitis B were tested and analyzed using ECLIA and ELISA. In addition, 50 suspected patients were selected for two test
APA, Harvard, Vancouver, ISO, and other styles
9

Rowe, Dianna J., Timothy A. Khalil, Michael N. Kammer, et al. "Abstract 7070: A deeper evaluation of cytokeratin fragment 21-1 as a lung cancer tumor marker and comparison of different assays." Cancer Research 85, no. 8_Supplement_1 (2025): 7070. https://doi.org/10.1158/1538-7445.am2025-7070.

Full text
Abstract:
Abstract Studies show CYFRA 21-1 fragments of cytokeratin 19 (CK19) to be promising biomarkers for non-small cell lung cancer (NSCLC). Although previous literature identifies specific CYFRA 21-1 antibody binding epitopes, the exact molecular weight of the CK19 fragment being detected by current assays is not well-documented. It is believed that during apoptosis, CK19 is cleaved by caspases and resulting fragments are released into the serum. A proposed caspase cleavage site is located between amino acids 235 and 238 of its sequence. Upon cleavage, two fragments are released; the fragment beari
APA, Harvard, Vancouver, ISO, and other styles
10

Grimnes, Guri, Bjørg Almaas, Anne Elise Eggen, et al. "Effect of smoking on the serum levels of 25-hydroxyvitamin D depends on the assay employed." European Journal of Endocrinology 163, no. 2 (2010): 339–48. http://dx.doi.org/10.1530/eje-10-0150.

Full text
Abstract:
ObjectiveBecause we found higher serum 25-hydroxyvitamin D (25(OH)D) levels among smokers than among non-smokers with analyses using an electrochemiluminescence immunoassay (ECLIA) from Roche, the purpose of the present study was to examine whether this difference between smokers and non-smokers was maintained using other serum 25(OH)D assays.DesignA cross-sectional population-based study on 6932 participants from the Tromsø study, 1994–1995, and one validation study comparing six different serum 25(OH)D assays in 53 non-smokers and 54 smokers were performed.MethodsThe association between smok
APA, Harvard, Vancouver, ISO, and other styles
11

Stove, Veronique, Pedro Alía Ramos, Pierre Wallemacq, et al. "Measurement of sirolimus concentrations in human blood using an automated electrochemiluminescence immunoassay (ECLIA): a multicenter evaluation." Clinical Chemistry and Laboratory Medicine (CCLM) 56, no. 5 (2018): 764–75. http://dx.doi.org/10.1515/cclm-2017-0583.

Full text
Abstract:
AbstractBackground:Therapeutic drug monitoring (TDM) of sirolimus is essential in transplant recipients. We evaluated the performance of a new electrochemiluminescence immunoassay (ECLIA) for measuring sirolimus concentrations in whole blood at five European laboratories.Methods:Study assessments included repeatability, intermediate precision and functional sensitivity (concentration at coefficient of variation [CV] of 20%) experiments. Method comparisons with liquid chromatography-tandem mass spectrometry (LC-MS/MS; reference method) and two immunoassays (chemiluminescent microparticle immuno
APA, Harvard, Vancouver, ISO, and other styles
12

Weber, Myriam C., Martin Risch, Sarah L. Thiel, et al. "Characteristics of Three Different Chemiluminescence Assays for Testing for SARS-CoV-2 Antibodies." Disease Markers 2021 (January 6, 2021): 1–13. http://dx.doi.org/10.1155/2021/8810196.

Full text
Abstract:
Several tests based on chemiluminescence immunoassay techniques have become available to test for SARS-CoV-2 antibodies. There is currently insufficient data on serology assay performance beyond 35 days after symptoms onset. We aimed to evaluate SARS-CoV-2 antibody tests on three widely used platforms. A chemiluminescent microparticle immunoassay (CMIA; Abbott Diagnostics, USA), a luminescence immunoassay (LIA; Diasorin, Italy), and an electrochemiluminescence immunoassay (ECLIA; Roche Diagnostics, Switzerland) were investigated. In a multigroup study, sensitivity was assessed in a group of pa
APA, Harvard, Vancouver, ISO, and other styles
13

Shimizu, Tomo, Takashi Sawada, Tomohide Asai, et al. "Hepatocellular carcinoma diagnosis using a novel electrochemiluminescence immunoassay targeting serum IgM-free AIM." Clinical Journal of Gastroenterology 15, no. 1 (2022): 41–51. http://dx.doi.org/10.1007/s12328-021-01567-4.

Full text
Abstract:
Abstract Background Recent increases in the number of patients with non-alcoholic steatohepatitis (NASH) warrant the identification of biomarkers for early detection of hepatocellular carcinoma (HCC) associated with NASH (NASH-HCC). IgM-free apoptosis inhibitor of macrophage (AIM), which generally associates with IgM in blood and exerts its biological function by dissociation from IgM, may serve as an effective biomarker for NASH-HCC. Here, we established a fully automatic and high-throughput electrochemiluminescence immunoassay (ECLIA) to measure IgM-free AIM and investigated its efficacy in
APA, Harvard, Vancouver, ISO, and other styles
14

Erdem Kinas, Burçin, Arzu Etem Akagac, Aybala Erek Toprak, Sule Batcık, and Ahmet Rıza Uras. "Comparison of enzyme-linked fluorescent assay and electrochemiluminescence immune assay in procalcitonin measurement." Turkish Journal of Biochemistry 47, no. 1 (2021): 19–22. http://dx.doi.org/10.1515/tjb-2020-0474.

Full text
Abstract:
Abstract Background Procalcitonin (PCT) measurement is required for intensive care patients with systemic inflammation symptoms, early diagnosis of possible infections, and evaluation of sepsis severity and prognosis. Objectives We aimed to determine the analytical performance of PCT measurement in a Roche Modular E170 (ECLIA) analyzer and compare the performance with VIDAS (BRAHMS/ELFA) analyzer findings. Material and methods Within-day and between-day precision value, linearity was determined, and two methods were compared with regression and Bland–Altman analysis. Results Both ECLIA and ELF
APA, Harvard, Vancouver, ISO, and other styles
15

Wu, Min, Haidong Liu, Zhaobo Liu, Chao Liu, Aiying Zhang, and Ning Li. "Analysis of serum alpha-fetoprotein (AFP) and AFP-L3 levels by protein microarray." Journal of International Medical Research 46, no. 10 (2018): 4297–305. http://dx.doi.org/10.1177/0300060518789304.

Full text
Abstract:
Objectives This study aimed to examine a simple, effective, time-saving, and low-cost protein microarray method for detecting serum alpha-fetoprotein (AFP) and AFP-L3 levels. Methods Serum samples from patients with hepatocellular carcinoma (HCC) (n = 33) and control subjects (n = 39) were collected and evaluated for the presence of AFP using a novel protein microarray. Glycoprotein (including AFP-L3) was enriched from crude samples by a Hotgen Biotech glycosyl capture spin column and then detected by protein microarray. An electrochemiluminescence immunoassay (ECLIA) was used to validate the
APA, Harvard, Vancouver, ISO, and other styles
16

Martín-Calderón, José Luis. "Biotin interference in several electrochemiluminescence immunoassays (eclia)." Anales de la Real Academia Nacional de Farmacia 87, no. 87(03) (2021): 239–46. http://dx.doi.org/10.53519/analesranf.2021.87.03.02.

Full text
Abstract:
– Background: The aim of this study is to define the interference of biotin in several endocrine, tumor marker, and vitamin assays performed by an electrochemiluminescence method, trying to determinate the critical level that causes biotin interference. – Material and methods: Working biotin solutions were prepared in phosphate-buffered saline (PBS) at different concentrations (10000, 7500, 5000, 2500, 1250, 625, and 312.5 ng/mL), which were spiked on the samples to obtain final concentrations ten-fold lower. Each serum biotin dilution was tested in triplicate, using at least two levels of ana
APA, Harvard, Vancouver, ISO, and other styles
17

Mouna, Lina, Mehdi Razazian, Sandra Duquesne, Anne-Marie Roque-Afonso, and Christelle Vauloup-Fellous. "Validation of a SARS-CoV-2 Surrogate Virus Neutralization Test in Recovered and Vaccinated Healthcare Workers." Viruses 15, no. 2 (2023): 426. http://dx.doi.org/10.3390/v15020426.

Full text
Abstract:
Vaccination against COVID-19 is the main public health approach to fight against the pandemic. The Spike (S) glycoprotein of SARS-CoV-2 is the principal target of the neutralizing humoral response. We evaluated the analytical and clinical performances of a surrogate virus neutralization test (sVNT) compared to conventional neutralization tests (cVNTs) and anti-S eCLIA assays in recovered and/or vaccinated healthcare workers. Our results indicate that sVNTs displayed high specificity and no cross-reactivity. Both eCLIA and sVNT immunoassays were good at identifying cVNT serum dilutions ≥1:16. T
APA, Harvard, Vancouver, ISO, and other styles
18

Massart, Catherine, Rémy Sapin, Jacqueline Gibassier, Arnaud Agin, and Michèle d'Herbomez. "Intermethod Variability in TSH-Receptor Antibody Measurement: Implication for the Diagnosis of Graves Disease and for the Follow-Up of Graves Ophthalmopathy." Clinical Chemistry 55, no. 1 (2009): 183–86. http://dx.doi.org/10.1373/clinchem.2008.115162.

Full text
Abstract:
Abstract Background: We compared the analytical and clinical performance of 3 porcine thyroid receptor antibody (TRAb) methods (1 second- and 2 new third-generation systems) with the conventional TRAb assay based on the human recombinant TSH receptor (hTRAK). Patients and Methods: We obtained sera from 86 patients with untreated Graves disease (GD) and 71 healthy controls. We measured TRAb concentrations by radioreceptor assay using the hTRAK (Brahms) or the porcine TSH receptor (pRRA) from Beckman-Coulter, by electrochemiluminescence immunoassay (ECLIA) with the Elecsys/Cobas (Roche), and by
APA, Harvard, Vancouver, ISO, and other styles
19

Sánchez-Carbayo, Marta, Antonia Espasa, Virtudes Chinchilla, et al. "New Electrochemiluminescent Immunoassay for the Determination of CYFRA 21-1: Analytical Evaluation and Clinical Diagnostic Performance in Urine Samples of Patients with Bladder Cancer." Clinical Chemistry 45, no. 11 (1999): 1944–53. http://dx.doi.org/10.1093/clinchem/45.11.1944.

Full text
Abstract:
Abstract Background: A new electrochemiluminescent immunoassay (ECLIA) has been developed for the determination of cytokeratin 19 (CYFRA 21-1) in the Elecsys 2010 immunoassay system. Urinary CYFRA 21-1 might have a role in the diagnosis of bladder cancer. Methods: We performed an analytical evaluation of the CYFRA 21-1 ECLIA for serum and urine samples. The clinical value of urinary CYFRA 21-1 for the detection of bladder cancer was evaluated through its measurement in 226 urine samples from symptomatic and asymptomatic controls. Results: At concentrations of 2–30 μg/L, within-assay imprecisio
APA, Harvard, Vancouver, ISO, and other styles
20

Shankar, R., S. Mummadi, and A. Yerram. "AMH estimation: a comparison between ELISA and ECLIA." Fertility and Sterility 110, no. 4 (2018): e266. http://dx.doi.org/10.1016/j.fertnstert.2018.07.757.

Full text
APA, Harvard, Vancouver, ISO, and other styles
21

Manescu, Ion Bogdan, Andreea Luca, Adina Hutanu, Andreea Truta, and Minodora Dobreanu. "Anti-thyroid peroxidase (TPO) antibodies – Comparative analysis of two automatic methods, ECLIA and CMIA." Revista Romana de Medicina de Laborator 32, no. 1 (2024): 33–40. http://dx.doi.org/10.2478/rrlm-2024-0009.

Full text
Abstract:
Abstract Introduction: Anti-thyroid peroxidase autoantibodies (TPO) is an essential diagnostic tool for autoimmune disorders of the thyroid gland. However, TPO results are not always comparable due to differences between methods. Here, we aimed to investigate the differences between two modern laboratory methods for TPO measurement: electrochemiluminescence (ECLIA) and chemiluminescence microparticle (CMIA) immunoassays. Methods: A total of 234 serum samples were tested on two methods: Cobas-e601 (ECLIA) and Alinity i (CMIA). TPO results were compared statistically both quantitatively and qual
APA, Harvard, Vancouver, ISO, and other styles
22

Kaku, Norihito, Fumitaka Nishimura, Yui Shigeishi, et al. "Performance of anti-SARS-CoV-2 antibody testing in asymptomatic or mild COVID-19 patients: A retrospective study in outbreak on a cruise ship." PLOS ONE 16, no. 9 (2021): e0257452. http://dx.doi.org/10.1371/journal.pone.0257452.

Full text
Abstract:
Objectives A few studies on antibody testing have focused on asymptomatic or mild coronavirus disease 2019 (COVID-19) patients with low initial anti-severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibody responses. Anti-SARS-CoV-2 antibody-testing performance was evaluated using blood samples from asymptomatic or mild COVID-19 patients. Methods Blood samples were collected from 143 COVID-19 patients during an outbreak on a cruise ship 3 weeks after diagnosis. Simultaneously, a follow-up SARS-CoV-2 genetic test was performed. Samples stored before the COVID-19 pandemic were also
APA, Harvard, Vancouver, ISO, and other styles
23

Temessadouno, Fara Wagbo, Jean Gilbert Ndong, Etienne Gignoux, et al. "Seroprevalence of anti-SARS-CoV-2 antibodies among blood donors from December 2020 to June 2021 in Koutiala district, Mali." PLOS Global Public Health 3, no. 1 (2023): e0001316. http://dx.doi.org/10.1371/journal.pgph.0001316.

Full text
Abstract:
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is the virus associated with coronavirus disease (COVID-19). At the time of the study, little data on the level of exposure of the population in Koutiala district in Mali to SARS-CoV-2 was available. Although blood donors are not representative of the general population, a COVID-19 seroprevalence estimate in this population was intended to assess the extent of community transmission, serve as a health alert system, and help guide the public health response. We measured seroprevalence of anti-SARS-CoV-2 antibodies using NG-Biotech SAR
APA, Harvard, Vancouver, ISO, and other styles
24

Navas-Castillo, Jessenia Sabrina, Byron Alexander Pérez-Aguilar, Maika Giamillete Aresti-Alvarado, and Ana Johanna Samayoa-Bran. "Correlación de prueba rápida y automatizada para detección de antígeno de superficie de hepatitis B." Ciencia Latina Revista Científica Multidisciplinar 7, no. 1 (2023): 2458–72. http://dx.doi.org/10.37811/cl_rcm.v7i1.4601.

Full text
Abstract:
Objetivo: Correlacionar pruebas rápidas para la detección de HBsAg con un ECLIA, utilizadas en dos periodos y conocer los costos adicionales derivados de los falsos positivos. Metodología: Se analizaron los resultados positivos a HBsAg de 934 muestras procesadas del 21 de octubre al 20 de diciembre del año 2021, utilizando la prueba rápida SD HBsAg WB (Multi) (01FK11W) BIOLINE (grupo A) y 990 muestras procesadas del 21 de diciembre del año 2021 al 21 de febrero del año 2022 utilizando la prueba rápida HBsAg 01FK1, 01FK11 Bioline™ (RAPID DIAGNOSTIC TEST Abbott), comparando con un ECLIA. Resulta
APA, Harvard, Vancouver, ISO, and other styles
25

Kovac, Marc, Lorenz Risch, Sarah Thiel, et al. "EDTA-Anticoagulated Whole Blood for SARS-CoV-2 Antibody Testing by Electrochemiluminescence Immunoassay (ECLIA) and Enzyme-Linked Immunosorbent Assay (ELISA)." Diagnostics 10, no. 8 (2020): 593. http://dx.doi.org/10.3390/diagnostics10080593.

Full text
Abstract:
While lateral flow test formats can be utilized with whole blood and low sample volumes, their diagnostic characteristics are inferior to immunoassays based on chemiluminescence immunoassay (CLIA) or enzyme-linked immunosorbent assay (ELISA) technology. CLIAs and ELISAs can be automated to a high degree but commonly require larger serum or plasma volumes for sample processing. We addressed the suitability of EDTA-anticoagulated whole blood as an alternative sample material for antibody testing against SARS-CoV-2 by electro-CLIA (ECLIA; Roche, Rotkreuz, Switzerland) and ELISA (IgG and IgA; Euro
APA, Harvard, Vancouver, ISO, and other styles
26

Zhang, Ning, Yuxin Zhu, Fachuang Li, et al. "Research progress on nanomaterial-empowered electrochemical biosensors for the detection of cardiac troponin I." RSC Advances 15, no. 32 (2025): 26473–89. https://doi.org/10.1039/d5ra04555j.

Full text
Abstract:
This article reviews carbon-based, metal/ceramic matrix, MOFs composites in electrochemical sensing, FETs, ECLIA. Detecting cTnI via biosensors, it shows trends, offers clinical references, and promotes lab-to-clinic advancement.
APA, Harvard, Vancouver, ISO, and other styles
27

Yamaguchi, Kazunari, Takashi Sawada, Tohru Naraki, et al. "Detection of Borna Disease Virus-Reactive Antibodies from Patients with Psychiatric Disorders and from Horses by Electrochemiluminescence Immunoassay." Clinical Diagnostic Laboratory Immunology 6, no. 5 (1999): 696–700. http://dx.doi.org/10.1128/cdli.6.5.696-700.1999.

Full text
Abstract:
ABSTRACT The prevalence of Borna disease virus (BDV)-specific antibodies among patients with psychiatric disorders and healthy individuals has varied in several reports using several different serological assay methods. A reliable and specific method for anti-BDV antibodies needs to be developed to clarify the pathological significance of BDV infections in humans. We developed a new electrochemiluminescence immunoassay (ECLIA) for the antibody to BDV that uses two recombinant proteins of BDV, p40 and p24 (full length). Using this ECLIA, we examined 3,476 serum samples from humans with various
APA, Harvard, Vancouver, ISO, and other styles
28

Ilyas, Ellya Latifah, JB Suparyatmo, and Amiroh Kurniati. "Determination of Cut-Off Index of Reactive HBsAg Based on Confirmatory Test at Dr. Moewardi Hospital." INDONESIAN JOURNAL OF CLINICAL PATHOLOGY AND MEDICAL LABORATORY 28, no. 1 (2021): 31–35. http://dx.doi.org/10.24293/ijcpml.v28i1.1726.

Full text
Abstract:
HBsAg confirmatory test is required to confirm false reactive HBsAg due to non-specific binding of antigen withantibody. HBsAg confirmatory test cannot be performed in every laboratory due to the high price of reagents, short reagentshelf life, prolonged turnaround time, and increasing complexity of the test. This study aimed to determine the HBsAg COI(cut-off unit) cut-off point, which requires a confirmatory HBsAg test on the COBAS e411 analyzer with the ECLIA method.An observational analytic study with a cross-sectional approach was performed on 59 patients who underwent the HBsAgtest at Dr
APA, Harvard, Vancouver, ISO, and other styles
29

Deng, Yan Fei, Ping Chen, Yong Zhi Lin, et al. "Analytical and clinical evaluation of CYFRA 21-1 by electrochemiluminescent immunoassay in head and neck squamous cell carcinoma." Journal of Laryngology & Otology 117, no. 3 (2003): 190–94. http://dx.doi.org/10.1258/002221503321192485.

Full text
Abstract:
This paper attempts to evaluate the clinical usefulness of CYFRA 21-1 as a serum tumour marker in patients with head and neck squamous cell carcinoma (HNSCC).The serum concentration of CYFRA 21-1 was measured utilizing a new electrochemiluminescent immunoassay (ECLIA) in 142 patients with HNSCC before and after treatment, 68 patients with benign tumours of the head and neck, and 50 healthy controls.Serum levels of CYFRA 21-1 in patients with HNSCC were significantly higher than those of benign tumours and healthy controls (p &lt; 0.001). The diagnostic sensitivity and specificity of CYFRA 21-1
APA, Harvard, Vancouver, ISO, and other styles
30

Zhao, Bing, Miaomiao Zhang, Feng Lin, Jing Xie, Yan Liang, and Zaixing Yang. "Establishment of the reference interval for serum pro-gastrin-releasing peptide in healthy adults of Chinese Han ethnicity." International Journal of Biological Markers 33, no. 4 (2018): 487–91. http://dx.doi.org/10.1177/1724600818783416.

Full text
Abstract:
Objective: The aim of this study is to establish the reference interval for serum pro-gastrin-releasing peptide (proGRP) determined by electrochemiluminescence immunoassay (ECLIA) in healthy Chinese Han ethnic adults. Methods: After screening, 9932 healthy Chinese Han adults (age range 18–95 years) were enrolled in this study, including 6220 men and 3712 women. Serum proGRP levels were measured by ECLIA. The reference interval was defined by non-parametric 95th percentile interval. Results: Serum proGRP levels conformed to a non-Gussian distribution. The reference interval for healthy Chinese
APA, Harvard, Vancouver, ISO, and other styles
31

Kuechler, Anna Sabrina, Eva Heger, Maike Wirtz, et al. "Ex Vivo Immune Responsiveness to SARS-CoV-2 Omicron BA.5.1 Following Vaccination with Unmodified mRNA-Vaccine." Vaccines 11, no. 3 (2023): 598. http://dx.doi.org/10.3390/vaccines11030598.

Full text
Abstract:
(1) Background: The high incidence of SARS-CoV-2 infection in vaccinated persons underscores the importance of individualized re-vaccination. PanIg antibodies that act against the S1/-receptor binding domain quantified in serum by a routine diagnostic test (ECLIA, Roche) can be used to gauge the individual ex vivo capacity of SARS-CoV-2 neutralization. However, that test is not adapted to mutations in the S1/-receptor binding domain, having accumulated in SARS-CoV-2 variants. Therefore, it might be unsuited to determine immune-reactivity against SARS-CoV-2 BA.5.1. (2) Method: To address this c
APA, Harvard, Vancouver, ISO, and other styles
32

Oshima, A., H. Uezawa, M. Munechika, S. Konishi, T. Sano, and M. Katayama. "Optical Dynamic Gain Equalizer using Parallel Motion Type of ECLIA." Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec) 2003 (2003): 87–88. http://dx.doi.org/10.1299/jsmermd.2003.87_7.

Full text
APA, Harvard, Vancouver, ISO, and other styles
33

Yaneva, Maria, Georgi Kirilov, and Sabina Zacharieva. "Midnight salivary cortisol, measured by highly sensitive electrochemiluminescence immunoassay, for the diagnosis of Cushing’s syndrome." Open Medicine 4, no. 1 (2009): 59–64. http://dx.doi.org/10.2478/s11536-009-0004-y.

Full text
Abstract:
AbstractThe aim of the present study is to evaluate the measurement of midnight salivary cortisol as a method of screening for Cushing’s syndrome (CS). Here we tested the performance of a highly sensitive electrochemiluminescence immunoassay (ECLIA) for midnight salivary cortisol measurement in an extensive clinical study (n=104). Three groups were investigated: 30 patients with CS, 34 with obesity and 40 healthy normal weight controls. All of them collected saliva samples at 24:00 h and urine samples over the same day (24 hour period). An electrochemiluminescence immunoassay was used to measu
APA, Harvard, Vancouver, ISO, and other styles
34

Parlant-Pinet, Lucile, Catherine Harthé, Florence Roucher, et al. "Macroprolactinaemia: a biological diagnostic strategy from the study of 222 patients." European Journal of Endocrinology 172, no. 6 (2015): 687–95. http://dx.doi.org/10.1530/eje-14-1073.

Full text
Abstract:
ObjectivesGel filtration chromatography (GFC), the gold standard for macroprolactinaemia (MPRL) diagnosis, is a slow, costly and labour-intensive method. To limit the number of GFC required, we evaluated two screening tests for MPRL: prolactin (PRL) recovery after polyethylene glycol (PEG) precipitation and PRL concentration ratio, derived from two assays, each having different big-big-PRL cross-reactivities.In some patients, MPRL is characterised by clinical symptoms which can be associated with an excess of monomeric PRL. We compared the monomeric PRL concentration obtained from GFC with the
APA, Harvard, Vancouver, ISO, and other styles
35

Risch, Martin, Marc Kovac, Corina Risch, et al. "An Anti-Nucleocapsid Antigen Sars-Cov-2 Total Antibody Assay Finds Comparable Results in Edta-Anticoagulated Whole Blood Obtained from Capillary and Venous Blood Sampling." Data 5, no. 4 (2020): 105. http://dx.doi.org/10.3390/data5040105.

Full text
Abstract:
Although SARS-CoV-2 antibody assays have been found to provide valid results in EDTA-anticoagulated whole blood, so far, they have not demonstrated that antibody levels in whole blood originating from capillary blood samples are comparable to antibody levels measured in blood from a venous origin. Here, blood is drawn simultaneously by capillary and venous blood sampling. Antibody titers are determined by an assay employing electrochemiluminescence (ECLIA) and SARS-CoV-2 total immunoglobulins are detected with specificity directed against the nucleocapsid antigen. Six individuals with confirme
APA, Harvard, Vancouver, ISO, and other styles
36

Liana, Phey, Mita Al Maida, Gita Dwi Prasasty, Desi Oktariana, and Tungki Pratama Umar. "Comparative Evaluation of Electrochemiluminescence and Chemiluminescence Microparticle Immunoassays for Anti-Hepatitis C Virus (HCV) Detection." Biomedical Journal of Indonesia 10, no. 3 (2024): 112–16. https://doi.org/10.32539/bji.v10i3.208.

Full text
Abstract:
Introduction. Anti-hepatitis C virus (HCV) testing is an immunological analysis designed to identify the presence of antibodies against the HCV antigen. This investigation is typically conducted using the chemiluminescence immunoassay (CLIA) technique, which yields precise results. Current research attempts to evaluate the outcomes of the anti-HCV test utilizing the Chemiluminescence Microparticle Immunoassay (CMIA) and the Electrochemiluminescence Immunoassay (ECLIA) approaches. Methods. This cross-sectional study comprised 63 serum samples collected via consecutive sampling. The acquired dat
APA, Harvard, Vancouver, ISO, and other styles
37

Lippi, Giuseppe, Brandon M. Henry, and Khosrow Adeli. "Diagnostic performance of the fully automated Roche Elecsys SARS-CoV-2 antigen electrochemiluminescence immunoassay: a pooled analysis." Clinical Chemistry and Laboratory Medicine (CCLM) 60, no. 5 (2022): 655–61. http://dx.doi.org/10.1515/cclm-2022-0053.

Full text
Abstract:
Abstract Objectives Among the diagnostic tests that have recently become commercially available for diagnosing coronavirus disease 2019 (COVID-19), the fully-automated Roche Elecsys severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antigen electrochemiluminescence immunoassay (ECLIA) is one of the most widespread for its adaptability within a system of laboratory automation, rapidity and high-throughput. This article is aimed to provide the results of the first pooled analysis of its accuracy for diagnosing SARS-CoV-2 infections. Content We carried out an electronic search in Scopus
APA, Harvard, Vancouver, ISO, and other styles
38

Masotti, Silvia, Veronica Musetti, Concetta Prontera, et al. "Evaluation of analytical performances using standardized analytical protocols and comparison of clinical results of the new ADVIA BNP and NT-proBNP immunoassays for the Centaur XPT platform." Clinical Chemistry and Laboratory Medicine (CCLM) 57, no. 6 (2019): 911–17. http://dx.doi.org/10.1515/cclm-2018-0760.

Full text
Abstract:
Abstract Background The study aim was to evaluate and compare analytical performances and clinical results of ADVIA BNP and PBNP methods using the Centaur XPT platform with those of Access BNP, using the DxI platform and the ECLIA NT-proBNP method, using the Cobas e411 platform, respectively. Methods Limits of blank (LoB), detection (LoD) and quantitation (LoQ) at 20% CV and 10% CV were evaluated according to international standardized protocols. The analytical parameters were assessed throughout a 90-working-day period using three curve calibrations. Results LoB, LoD and LoQ at 20% CV and 10%
APA, Harvard, Vancouver, ISO, and other styles
39

Belaya, Zhanna Evgenyevna, Aleksandr Viktorovich Il'in, Galina Afanasyevna Mel'nichenko, et al. "Avtomatizirovannyy elektrokhemilyuminestsentnyy metod opredeleniya kortizola v slyune dlya diagnostiki endogennogo giperkortitsizma sredi patsientov s ozhireniem." Obesity and metabolism 8, no. 2 (2011): 56–63. http://dx.doi.org/10.14341/2071-8713-4954.

Full text
Abstract:
Nighttime salivary cortisol (NSC) has been suggested to be a useful diagnostic test for Cushings syndrome (CS). However, the reference range and cut-off value are assay-specific and discordant. The goal of this study was to assess the analytical performance of automated elecrochemiluminiscence immunoassay method (ECLIA) in CS. Ninety eight healthy volunteers and 123 obese patients including 45 proved to be CS provided salivary samples collected by them at 23:00 using Sallivette. Two hundred and five subjects collected salivary samples for two consecutive days and samples from 197 subjects were
APA, Harvard, Vancouver, ISO, and other styles
40

Malaeb, Rami, Nagwan Yousef, Omar Al-Nagdah, et al. "High seroprevalence of antibodies against SARS-CoV-2 among healthcare workers 8 months after the first wave in Aden, Yemen." PLOS Global Public Health 2, no. 11 (2022): e0000767. http://dx.doi.org/10.1371/journal.pgph.0000767.

Full text
Abstract:
The true burden of COVID-19 in Yemen is underestimated. The healthcare system is dysfunctional and there is a high shortage of health care workers in the country. Testing for SARS-CoV-2 remains limited and official surveillance data is restricted to those who are severe or highly suspected. In this study, Médecins Sans Frontières (MSF) aimed to conduct serological screening using rapid tests for asymptomatic staff at the MSF Aden Trauma Center to determine the SARS-CoV-2 antibody seropositivity. Four months after the peak of the first wave, we offered all the staff at the MSF Aden Trauma Cente
APA, Harvard, Vancouver, ISO, and other styles
41

Lerdsamran, Hatairat, Ratikorn Anusorntanawat, Kantima Sangsiriwut, et al. "Higher correlation between neutralizing antibodies and surrogate neutralizing or binding antibodies in COVID-19 patients than vaccine recipients." PLOS ONE 19, no. 4 (2024): e0298033. http://dx.doi.org/10.1371/journal.pone.0298033.

Full text
Abstract:
This study determined the seropositive rates and levels of antibodies to severe acute respiratory syndrome coronavirus-2 in 50 patients and 108 vaccinees using microneutralization test (MNT), surrogate virus neutralization test (sVNT), chemiluminescent microparticle immunoassay (CMIA), and electrochemiluminescence immunoassay (ECLIA). MNT, as the reference method, employed living clade S and Delta viruses to measure neutralizing (NT) antibodies, while sVNT employed wild type strain and Delta receptor-binding domains (RBD) as the test antigens to measure sVNT antibodies. CMIA and ECLIA employed
APA, Harvard, Vancouver, ISO, and other styles
42

Bořecká, K., V. Jamriková, P. Sojka, Z. Khaznadar, and M. Ibrahimová. "Measurement of anti-SARS-CoV-2 antibodies nucleocapsid versus spike, ECLIA versus ELISA." Klinická biochemie a metabolismus 29, no. 1 (2021): 19–24. https://doi.org/10.61568/kbm.2021.004.

Full text
APA, Harvard, Vancouver, ISO, and other styles
43

Wang, Tianqi, Zeyu Li, Yuqing Jia, Baoli Zhu, and Zhipeng Cao. "Interference of hemolysis on the postmortem biochemical analysis of IgE by ECLIA." International Journal of Legal Medicine 135, no. 4 (2021): 1661–68. http://dx.doi.org/10.1007/s00414-021-02578-z.

Full text
APA, Harvard, Vancouver, ISO, and other styles
44

Werner, Maren, Philip Pervan, Vivian Glück, et al. "Evaluation of a Broad Panel of SARS-CoV-2 Serological Tests for Diagnostic Use." Journal of Clinical Medicine 10, no. 8 (2021): 1580. http://dx.doi.org/10.3390/jcm10081580.

Full text
Abstract:
Serological testing is crucial in detection of previous infection and in monitoring convalescent and vaccine-induced immunity. During the Severe Acute Respiratory Syndrome Corona Virus 2 (SARS-CoV-2) pandemic, numerous assay platforms have been developed and marketed for clinical use. Several studies recently compared clinical performance of a limited number of serological tests, but broad comparative evaluation is currently missing. Within this study, a panel of 161 sera from SARS-CoV-2 infected, seasonal CoV-infected and SARS-CoV-2 naïve subjects was enrolled to evaluate 16 ELISA/ECLIA-based
APA, Harvard, Vancouver, ISO, and other styles
45

Hsu Chen, Cheng, Erick Wang, Tsung-Han Lee, et al. "Point-of-Care NSE Biosensor for Objective Assessment of Stroke Risk." Biosensors 15, no. 4 (2025): 264. https://doi.org/10.3390/bios15040264.

Full text
Abstract:
The rapid identification of stroke is critical to improving stroke patient outcomes. Existing protocols for assessing the risk of stroke are subjective and may be further complicated by nonspecific symptoms, increasing the risk of misdiagnosis. Neuron-specific enolase (NSE) has emerged as a promising stroke biomarker. However, current detection methods such as the electrochemiluminescence immunoassay (ECLIA) are time-consuming and costly. In this research, we developed an electrochemical biosensor for the rapid quantification of NSE in whole blood. Mouse stroke models were established, and blo
APA, Harvard, Vancouver, ISO, and other styles
46

Bandar, Ivo Sah, He Sarina Yang, Alex Rai, et al. "Comparison of five tacrolimus measurement methods underscore the need for a standardized method to improve clinical outcomes." American Journal of Clinical Pathology 162, Supplement_1 (2024): S181. http://dx.doi.org/10.1093/ajcp/aqae129.397.

Full text
Abstract:
Abstract Tacrolimus is a widely used drug to prevent post-transplantation organ rejection by suppressing host immune response. While its efficacy is well established, tacrolimus is also known for narrow therapeutic index and debilitating adverse effects, rendering accurate measurement for therapeutic drug monitoring essential, to minimize drug toxicity and graft loss, and maximize organ rejection prevention. Tacrolimus can be quantitated by immunoassay (IA) and liquid chromatography-tandem mass spectrometry (LC-MS/MS). However, previous pairwise studies showed significant inter-assay variabili
APA, Harvard, Vancouver, ISO, and other styles
47

Vieira, José Gilberto H., Odete H. Nakamura, Cláudia Maria Ferrer, Teresinha T. Tachibana, Maria Helena K. Endo, and Valdemir M. Carvalho. "Importância da metodologia na dosagem de testosterona sérica: comparação entre um imunoensaio direto e um método fundamentado em cromatografia líquida de alta performance e espectrometria de massa em tandem (HPLC/MS-MS)." Arquivos Brasileiros de Endocrinologia & Metabologia 52, no. 6 (2008): 1050–55. http://dx.doi.org/10.1590/s0004-27302008000600017.

Full text
Abstract:
A dosagem de testosterona sérica, total ou fração livre, é metodologia de alto valor diagnóstico e encontra-se disponível na maioria dos laboratórios clínicos. Esta disponibilidade foi possível pelo desenvolvimento de metodologias simples e diretas, adaptáveis a plataformas de dosagem automatizada. Uma série de publicações recentes tem alertado quanto às limitações destas metodologias, em especial em amostras com baixas concentrações, como mulheres e crianças. Neste trabalho serão apresentados os resultados do emprego de uma metodologia de referência, fundamentada em cromatografia líquida de a
APA, Harvard, Vancouver, ISO, and other styles
48

HOU, YAN-FENG, GUANG-ZHI SUN, HONG-SHENG SUN, WEN-PING PAN, WEN-BO LIU, and CHENG-QI ZHANG. "Diagnostic Value of Anti-Sa and Anticitrullinated Protein Antibodies in Rheumatoid Arthritis." Journal of Rheumatology 39, no. 8 (2012): 1506–8. http://dx.doi.org/10.3899/jrheum.111523.

Full text
Abstract:
Objective.To determine the diagnostic value of anticitrullinated protein antibodies, second generation (ACPA2), by electrochemiluminescent immunoassay (ECLIA) and anti-Sa by ELISA in a large cohort of Chinese patients with early rheumatoid arthritis (RA).Methods.One hundred ninety-eight patients with early RA (&lt; 1 yr duration), 112 with other rheumatic diseases, and 60 healthy individuals were studied.Results.The combination of anti-Sa and ACPA2 positivity had the highest specificity (99.42%), but it had a rather low sensitivity (50.0%). The combination of anti-rheumatoid factor (RF) and AC
APA, Harvard, Vancouver, ISO, and other styles
49

IBRAHIMI, Jehona, Mije REÇI, and Sheval F MEMISHI. "PREVALENCE OF HYPERTHYROIDISM IN THE TETOVO REGION, NORTH MACEDONIA." Journal of Natural Sciences and Mathematics of UT-JNSM 9, no. 17-18 (2024): 20–27. http://dx.doi.org/10.62792/ut.jnsm.v9.i17-18.p2792.

Full text
Abstract:
Hyperthyroidism is a pathological disorder characterized by increased thyroid hormone synthesis and secretion from the thyroid gland, whereas thyrotoxicosis refers to the clinical syndrome of excess circulating thyroid hormones, irrespective of the source. The most common cause of hyperthyroidism is Graves’ disease, followed by toxic nodular goiter. Other important causes of thyrotoxicosis include thyroiditis, iodine-induced and drug-induced thyroid dysfunction, and factitious ingestion of excess thyroid hormones. Unrecognized and untreated hyperthyroidism leads to serious clinical complicatio
APA, Harvard, Vancouver, ISO, and other styles
50

Dolscheid-Pommerich, Ramona C., Sarah Dolscheid, Lars Eichhorn, Berndt Zur, Stefan Holdenrieder, and Birgit Stoffel-Wagner. "Method comparison of tumor markers assessed by LOCI™- and ECLIA-based technologies." LaboratoriumsMedizin 41, no. 1 (2017): 3–11. http://dx.doi.org/10.1515/labmed-2016-0074.

Full text
Abstract:
AbstractBackground:Since the introduction of luminescent oxygen channeling immunoassays (LOCI™)-based assays in the daily laboratory routine of tumor marker measurements, only a small number of method comparisons with established immunoassays have been published. We performed a method comparison between LOCI™-based tumor marker assays for Dimension™ VISTA and electrochemiluminiscent immunoassays (ECLIA) for Cobas™ e411, for α-fetoprotein (AFP), carcinoembryonic antigen (CEA), CA 125, CA 15-3, CA 19-9, prostate-specific antigen (PSA) and free PSA (fPSA).Methods:Tumor markers were assessed in 10
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!