Academic literature on the topic 'Elastografia por Ressonância Magnética'
Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles
Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Elastografia por Ressonância Magnética.'
Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.
You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.
Journal articles on the topic "Elastografia por Ressonância Magnética"
Vieira, Sílvio Leão, Lucas Nonato de Oliveira, and Antonio Adilton Oliveira Carneiro. "Princípios físicos da elastografia por ressonância magnética." Revista Brasileira de Ensino de Física 36, no. 2 (June 2014): 1–15. http://dx.doi.org/10.1590/s1806-11172014000200001.
Full textMelo, Homero José de Farias e., Denis Szejnfeld, Cristiano Silveira Paiva, Nitamar Abdala, Homero Oliveira de Arruda, Suzan Menasce Goldman, and Jacob Szejnfeld. "Espectroscopia por ressonância magnética no diagnóstico do câncer de próstata: experiência inicial." Radiologia Brasileira 42, no. 1 (February 2009): 1–6. http://dx.doi.org/10.1590/s0100-39842009000100003.
Full textArruda, Elaine Cristina de Moraes, Julio Cezar Uili Coelho, Jorge Massayuki Yokochi, and Jorge Eduardo Fouto Matias. "O papel da colangiografia por ressonância magnética na avaliação da anatomia biliar em doadores de transplante hepático intervivos." Radiologia Brasileira 41, no. 6 (December 2008): 361–65. http://dx.doi.org/10.1590/s0100-39842008000600004.
Full textHage, Maria Cristina Ferrarini Nunes Soares, and Masao Iwasaki. "Imagem por ressonância magnética: princípios básicos." Ciência Rural 39, no. 4 (March 27, 2009): 1275–83. http://dx.doi.org/10.1590/s0103-84782009005000041.
Full textSouza, Patrícia Martins e., Marcelo Sadock de Sá Gabetto, Marcelo Ganem Serrão, Luiz Antônio Martins Vieira, and Diogo Cals de Oliveira. "Instabilidade femoropatelar: avaliação por ressonância magnética." Revista Brasileira de Ortopedia 48, no. 2 (March 2013): 159–64. http://dx.doi.org/10.1016/j.rbo.2012.04.001.
Full textLeite, Claudia da Costa. "Espectroscopia de prótons por ressonância magnética." Radiologia Brasileira 34, no. 1 (February 2001): V—VI. http://dx.doi.org/10.1590/s0100-39842001000100001.
Full textMazzola, Alessandro André, Karine Isabela Stieven, Guilherme Hohgraefe Neto, and Gerogina De Melo Cardoso. "Segurança em Imagem por Ressonância Magnética." Revista Brasileira de Física Médica 13, no. 1 (September 1, 2019): 76. http://dx.doi.org/10.29384/rbfm.2019.v13.n1.p76-91.
Full textBrandão, Rosieny Souza, Claudio Rodrigues Pires, Eduardo de Souza, Francisco da Silva Maciel Junior, Antonio Fernandes Moron, and Rosiane Mattar. "Avaliação biométrica do colo uterino durante a gestação por meio da ultra-sonografia transvaginal e ressonância magnética." Radiologia Brasileira 41, no. 4 (August 2008): 235–39. http://dx.doi.org/10.1590/s0100-39842008000400007.
Full textScortegagna Junior, Eduardo, Alberto Ribeiro de Souza Leão, José Eduardo Mourão Santos, Danilo Moulin Sales, David Carlos Shigueoka, Luciane Aparecida Kopke de Aguiar, Paulo Eugênio Brant, Ramiro Colleoni Neto, Durval Rosa Borges, and Giuseppe D'Ippolito. "Avaliação da concordância entre ressonância magnética de ultra-sonografia na classificação de fibrose periportal em esquitossomóticos, segundo a classificação de Niamey." Radiologia Brasileira 40, no. 5 (October 2007): 303–8. http://dx.doi.org/10.1590/s0100-39842007000500005.
Full textCastellano, Gabriela, and Carlos Ernesto Garrido Salmon. "Técnicas quantitativas de imagens por ressonância magnética." Revista Brasileira de Física Médica 13, no. 1 (September 1, 2019): 57. http://dx.doi.org/10.29384/rbfm.2019.v13.n1.p57-65.
Full textDissertations / Theses on the topic "Elastografia por Ressonância Magnética"
Vieira, Silvio Leão. "Imagens das propriedades viscoelásticas por ressonância magnética e ultrassom." Universidade de São Paulo, 2009. http://www.teses.usp.br/teses/disponiveis/59/59135/tde-22042010-093544/.
Full textThe viscoelasticity of injured biological tissues is the physical property that changes the most in relation to normal tissue. Manual palpation is commonly used to identify these lesions, such as nodules and cysts. Recently, several studies involving ultrasound and magnetic resonance imaging techniques, called elastography, have been employed to assess the viscoelastic properties of these lesions. One difficulty in this type of study is related to the development of biological tissues mimicking materials with similar inclusions, once these injured structures originate from anomalies within the biological tissue. Based on these motivations, quantitative elastographic techniques based on magnetic resonance and ultrasound modalities have been used to assess injuries in viscoelastic mimicking-tissue phantom materials. These lesions, with different viscoelastic properties, were generated within a phantom using ionizing radiation. The phantoms, also known as dosimeter gel, were developed based on animal skin powder, and irradiated using a conventional radiation therapy system. Magnetic resonance relaxometry images (MRR) were acquired in these phantoms, and were used as absorbed dose standard reference and its distribution. The estimated dose distribution profiles from these images and the ones provided by TPS 3D software radiotherapy planning system were compared to the elastograms. The elastographic studies were conducted using Vibro-acoustography (VA), Magnetic Resonance Elastography (MRE) and Shearwave Dispersion Ultrasound Vibrometry (SDUV) techniques. The second goal of this thesis was to explore the feasibility of speckle existence in vibro-acoustography images. To test that, a three-dimensional (3D) model for the systems point spread function (PSF) was simulated. The simulation code was implemented in MATLAB and using the program Field II subroutines. The numerical simulations were performed using a cluster of high performance computers. B-mode ultrasound and VA images were simulated using that PSF 3D model, for a spherically focused and a confocal transducer, respectively. These B-mode images were simulated as a comparative parameter to the images generated by VA. The B-mode ultrasound images were displayed in a tomographic plane corresponding to the VA imaging plane. All images were simulated using a virtual phantom with dimensions (10 × 10 × 50) mm3. Preliminary results showed a interference pattern in VA images taken with a confocal transducer. These images were produced from scatterers located inside the PSF resolution cell volume.
Beckmann, Nicolau. "Geração de imagens por ressonância magnética nuclear." Universidade de São Paulo, 1986. http://www.teses.usp.br/teses/disponiveis/54/54132/tde-03062015-105553/.
Full textThis work treats two techniquesfor the generation of images by nuclear magnetic resonance, the method of the direct transform. These techniques are based on the acquisition of NMR signals whose phases and frequency components gradients. The construction of gradient coils is discussed for the particular geometry appropriate for a magnet with pole caps and air gap. It contains also an analysis of the obtention of contrast by the relaxation times T1 and T2 in images reconstructed from signals generated employing sequences such as spin-echo, inversion-recovery and stimulated echo. In form of an appendix, a mathematical formalism is presented, that furnishes a matrix solution for the BLOCH equations, allowing the determination of the evolution of a signal in presence of gradients and radiofrequency pulses, and the dependence of its magnitude with relaxation times of the sample.
Vedolin, Leonardo Modesti. "Ressonância magnética cerebral e espectroscopia de prótons por ressonância magnética na investigação de pacientes com mucopolissacaridose." reponame:Biblioteca Digital de Teses e Dissertações da UFRGS, 2006. http://hdl.handle.net/10183/10737.
Full textThe mucopolysaccharidosis are a group of lysosomal diseases characterized by enzymatic deficiency which leads incomplete degradation of glycosaminoglycans. Neurological expression varies according to each enzyme but mental compromise is characteristic of MPS III and the severe forms of MPS I, II and VII. Studies with magnetic resonance imaging (MRI) demonstrated that brain atrophy, white matter (WM) lesions and hydrocephalus are common in MPS patients. However, correlation among MRI, biochemical changes and severity of neurological deficit was not published so far. In addition, comparison between MR spectroscopy (MRS) and MRI is controversial. The purpose of this study was to analyze MRI and MRS findings in MPS patients. Sixty patients with MPS types I, II, IV and VI were evaluated with MRI and MRS. Results were compared with disease duration, biochemical changes and cognitive impairment. MRI exams were performed in high field MRI scanner (1.5 T). Patients with longer disease duration had more WM lesions. Brain atrophy and hydrocephalus were not affected by disease duration or patient´s age. Patients with MPS II and cognitive impairment had more brain atrophy, hydrocephalus, severe WM lesions and elevated myoinositol/creatine at MRS. These results can be useful to better understand the pathogenic process and to increase the applicability of MRI in the disease investigation.
Bueno, Laís Melicio Cintra. "Estudo neuroanatômico do éncefalo bovino por ressonância magnética /." Botucatu, 2015. http://hdl.handle.net/11449/132005.
Full textBanca: Maria Cristina Ferrarini Nunes Soares Hage
Banca: Seizo Yamachita
Resumo: A imagem originada por ressonância magnética (MRI) revolucionou a medicina veterinária na área de diagnóstico por imagem. Tecnologia considerada atualmente como a metodologia mais sensível para análise de tecidos moles, como o encéfalo, ultrapassando os demais métodos diagnósticos. Essa tecnologia fundamenta-se no fenômeno da ressonância magnética nuclear que ocorre quando os núcleos atômicos com propriedades magnéticas presentes no corpo dos humanos e dos animais são submetidos a um campo magnético intenso. Suas vantagens na produção de imagens do encéfalo são método não invasivo, caracteriza-se por alta resolução, intenso contraste, plano bidimensional, em tons de cinza, produz menos artefatos e não utiliza formatos ionizantes de energia eletromagnética. Não apresenta riscos comprovados para o paciente e profissionais submetidos ao exame. Apesar da MRI ser a técnica de eleição para examinar o encéfalo, essas informações são escassas quando relacionadas com características anatômicas encefálicas em ruminantes domésticos. A finalidade deste estudo é descrever neuroanatomia encefálica bovina (Bos taurus domesticus) normal objetivando correlações com achados normais de ressonância magnética. Este trabalho reveste-se de importância pois, a definição neuroanatômica normal propiciará diagnósticos acurados de diferentes enfermidades traumáticas, vasculares, infecciosas, degenerativas ou neoplásicas, dentre outras Os cérebros foram cuidadosamente extraídos e fixados em formol para cortes anatômicos convencionais. Cortes transversais e sagitais de MRI foram obtidos de duas cabeças frescas de bovinos adultos pelo aparelho ESAOTE 0.25 T Vet-MR GRANDE através da bobina C-shaped coil nas sequências efetuadas no plano transversal T1 e T2 no plano sagital, T1 e T2 e no plano dorsal. Após a aquisição, imagens foram transferidas em formato DICON para o aplicativo...
Abstract: Magnetic resonance imaging (MRI) has revolutionized veterinary medicine in the field of diagnostic imaging. Technology currently considered as the most sensitive method for the analysis of soft tissues such as the brain, bypassing the other diagnostic methods. This technology is based on nuclear magnetic resonance phenomenon that occurs when atomic nuclei with magnetic properties present in the body of humans and animals are subjected to an intense magnetic field. Its advantages in the production of brain images are noninvasive, is characterized by high resolution, high contrast, two-dimensional plane, grayscale, produces less artifacts and does not use ionizing formats of electromagnetic energy. Presents no risk to the patient and proven professionals submitted to the examination. Although MRI is the preferred technique to examine the brain, this information is scarce when related brain anatomical features in domestic ruminants. The purpose of this study is to describe normal bovine brain neuroanatomy (Bos taurus domesticus) order correlations with normal magnetic resonance imaging findings. This research is of importance because, normal neuroanatomical definition will provide accurate diagnosis of different diseases traumatic, vascular, infectious, degenerative or neoplastic, among other. Brains were carefully extracted and fixed for conventional anatomical cuts. Transverse and sagittal MRI were obtained from two fresh heads of adult cattle at 0.25T ESAOTE Vet-MR GRANDE device through the coil C-shaped coil in the sequences performed in the transverse plane T1 and T2 sagittal, T1 and T2 and the plan dorsal. After the acquisition, images were transferred in DICON format for Synapse® PACS application and analyzed by an observer at ClearCanvas Workstation program. The most clinical interest neuroanatomical structures were set according to the methodology of Yokoshi & Rohen and named after neuroanatomy texts
Mestre
Bueno, Laís Melicio Cintra. "Estudo das enfermidades encefálicas diagnosticadas por ressonância magnética." Botucatu, 2018. http://hdl.handle.net/11449/180584.
Full textResumo: A ressonância magnética é um método diagnóstico primordial na avaliação de enfermidades intracranianas na medicina e na medicina veterinária para a investigação, elaboração e realização de tratamentos, planejamento cirúrgico e controle. Por meio dessa modalidade diagnóstica pode-se pesquisar muitas enfermidades intracranianas: congênitas, malformações, inflamatórias, infecciosas, vasculares, neoplásicas dentre outras. Ressonância magnética é um exame não invasivo, baseado em princípios físicos complexos que formam imagens em múltiplos planos de uma determinada região. O objetivo deste trabalho é fornecer um estudo retrospectivo das enfermidades neurológicas presentes na rotina de exames de ressonância magnética da região crânio -encefálica e sua casuística na Faculdade de Medicina Veterinária e Zootecnia da Universidade Estadual Paulista, campus de Botucatu nos anos de 2012 a 2017. Realizou-se uma análise retrospectiva dos exames de ressonância magnética de pequenos animais da região crânio- encefálica. Os dados foram compilados e classificados segundo a região de exame, diferentes áreas de encaminhamento, casuística das enfermidades intracranianas segundo a espécie durante o período de 2012 a 2017. Dentre os 420 animais, sendo eles 340 canídeos e 80 felídeos observou-se dentre as regiões de exame o encéfalo com 95%; maioria dos encaminhamentos para a realização do exame de ressonância magnética são recebidos do serviço de neurologia veterinária 58%; a casuística das suspeita... (Resumo completo, clicar acesso eletrônico abaixo)
Abstract: Magnetic resonance imaging is a primordial diagnostic method in the evaluation of intracranial diseases in medicine and veterinary medicine for investigation, elaboration and realization of treatments, surgical planning and control. By means of this diagnostic modality, one can investigate many intracranial diseases: congenital, malformations, inflammatory, infectious, vascular, and neoplastic among others. Magnetic resonance imaging is a non-invasive examination based on complex physical principles that form multi-plane imaging of a region. The goal of this work is to provide a retrospective study of the neurological diseases present in routine magnetic resonance imaging of the cranioencephalic region and its casuistry at the Faculty of Veterinary Medicine and Animal Science of the Universidade Estadual Paulista, Campus Botucatu, from 2012 to 2017. Was made a retrospective analysis of magnetic resonance imaging of small animals of the craniocephalic region. The data were compiled and classified according to the region of examination, different routing areas, and the number of intracranial diseases according to the species during the period from 2012 to 2017. Among the 420 animals, of which 340 canines and 80 felids were observed among the regions examination of the brain with 95%; most referrals for performing the MRI are received from the Veterinary Neurology Service 58%; the casuistry of the diagnostic suspicions of the diseases with 54 animals with convulsion, 49 animals ... (Complete abstract click electronic access below)
Doutor
Bueno, Laís Melicio Cintra [UNESP]. "Estudo neuroanatômico do éncefalo bovino por ressonância magnética." Universidade Estadual Paulista (UNESP), 2015. http://hdl.handle.net/11449/132005.
Full textCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
A imagem originada por ressonância magnética (MRI) revolucionou a medicina veterinária na área de diagnóstico por imagem. Tecnologia considerada atualmente como a metodologia mais sensível para análise de tecidos moles, como o encéfalo, ultrapassando os demais métodos diagnósticos. Essa tecnologia fundamenta-se no fenômeno da ressonância magnética nuclear que ocorre quando os núcleos atômicos com propriedades magnéticas presentes no corpo dos humanos e dos animais são submetidos a um campo magnético intenso. Suas vantagens na produção de imagens do encéfalo são método não invasivo, caracteriza-se por alta resolução, intenso contraste, plano bidimensional, em tons de cinza, produz menos artefatos e não utiliza formatos ionizantes de energia eletromagnética. Não apresenta riscos comprovados para o paciente e profissionais submetidos ao exame. Apesar da MRI ser a técnica de eleição para examinar o encéfalo, essas informações são escassas quando relacionadas com características anatômicas encefálicas em ruminantes domésticos. A finalidade deste estudo é descrever neuroanatomia encefálica bovina (Bos taurus domesticus) normal objetivando correlações com achados normais de ressonância magnética. Este trabalho reveste-se de importância pois, a definição neuroanatômica normal propiciará diagnósticos acurados de diferentes enfermidades traumáticas, vasculares, infecciosas, degenerativas ou neoplásicas, dentre outras Os cérebros foram cuidadosamente extraídos e fixados em formol para cortes anatômicos convencionais. Cortes transversais e sagitais de MRI foram obtidos de duas cabeças frescas de bovinos adultos pelo aparelho ESAOTE 0.25 T Vet-MR GRANDE através da bobina C-shaped coil nas sequências efetuadas no plano transversal T1 e T2 no plano sagital, T1 e T2 e no plano dorsal. Após a aquisição, imagens foram transferidas em formato DICON para o aplicativo...
Magnetic resonance imaging (MRI) has revolutionized veterinary medicine in the field of diagnostic imaging. Technology currently considered as the most sensitive method for the analysis of soft tissues such as the brain, bypassing the other diagnostic methods. This technology is based on nuclear magnetic resonance phenomenon that occurs when atomic nuclei with magnetic properties present in the body of humans and animals are subjected to an intense magnetic field. Its advantages in the production of brain images are noninvasive, is characterized by high resolution, high contrast, two-dimensional plane, grayscale, produces less artifacts and does not use ionizing formats of electromagnetic energy. Presents no risk to the patient and proven professionals submitted to the examination. Although MRI is the preferred technique to examine the brain, this information is scarce when related brain anatomical features in domestic ruminants. The purpose of this study is to describe normal bovine brain neuroanatomy (Bos taurus domesticus) order correlations with normal magnetic resonance imaging findings. This research is of importance because, normal neuroanatomical definition will provide accurate diagnosis of different diseases traumatic, vascular, infectious, degenerative or neoplastic, among other. Brains were carefully extracted and fixed for conventional anatomical cuts. Transverse and sagittal MRI were obtained from two fresh heads of adult cattle at 0.25T ESAOTE Vet-MR GRANDE device through the coil C-shaped coil in the sequences performed in the transverse plane T1 and T2 sagittal, T1 and T2 and the plan dorsal. After the acquisition, images were transferred in DICON format for Synapse® PACS application and analyzed by an observer at ClearCanvas Workstation program. The most clinical interest neuroanatomical structures were set according to the methodology of Yokoshi & Rohen and named after neuroanatomy texts
Rodrigues, Pedro Miguel Leal. "Estudos estruturais em ferredoxinas por ressonância magnética nuclear." Doctoral thesis, Faculdade de Ciências e Tecnologia, 1999. http://hdl.handle.net/10362/4450.
Full textAs ferredoxinas são proteínas de baixo peso molecular que contêm agregados [Fe-S] do tipo [3Fe-4S], [4Fe-4S], [3Fe-4S] + [4Fe-4S] e 2 x [4Fe-4S], podendo ser utilizadas como compostos modelo na investigação das propriedades electrónicas, paramagnéticas e estruturais de agregados [Fe-S] em enzimas complexas. A ferredoxina II (FdII) isolada da bactéria redutora de sulfato Desulfovibrio gigas (Dg) é uma proteína tetramérica de transferência electrónica com 58 resíduos de amino ácidos(seis cisteínas), que contém um centro [3Fe-4S] coordenado por três ligandos cisteicos; Cys 8,Cys 14 e Cys 50, e uma ponte dissulfureto entre os resíduos Cys 18 e Cys 42. A caracterização tanto bioquímica como espectroscópica recorrendo nomeadamente à espectroscopia de Ressonância Magnética Nuclear de 10 e 20, em conjunção com outras técnicas espectroscópicas, tais como a Ressonância Paramagnética Electrónica, UV/Vísivel e Mõssbauer foi já realizada para o estado oxidado desta proteína, de forma a compreender as suas propriedades redox e electrónicas. Durante o estudo do comportamento redox desta proteína foi descoberto um intermediário, DgFdIIinb originado pelo abertura da ponte dissulfureto. Devido à sua estabilidade, e utilizando as mesmas técnicas já utilizadas anteriormente para o estado oxidado, foi possível obter a sua caracterização. São assim apresentadas as atribuições específicas das ressonâncias pertencentes aos protões I3-CHz dos resíduos cisteicos,coordenantes e a análise da dependência angular das mesmas, possibilitando juntamente com as coordenadas de raios-X para o estado oxidado, uma comparação dos ângulos diedros entre os estados oxidado e intermediário da DgFdlI. Foi também introduzido um novo modelo de acoplamento de spins para o estado intermediário de modo a obter valores para as constantes de acoplamento, J dos átomos de ferro do agregado metálico. A existência de um quarto sítio desocupado no agregado [3Fe-4S] (Cys 11), abre a possibilidade da inserção de um quarto átomo metálico. Foi assim sintetizado o agregado misto [Co, 3Fe-4S] para o qual foi realizada uma breve análise espectroscópica, permitindo pela primeira vez a obtenção de um espectro de RMN de 10 e a análise das ressonâncias situadas no envelope paramagnético do mesmo, para os estados oxidado e reduzido do centro heterometálico. Tendo em conta a dificuldade de obtenção da DgFdII em termos de tempo e de quantidade, foi feita a clonagem e sobre-expressão desta proteína em E.coZi, utilizando o vector de expressão pT7-7. Foi posteriormente realizada uma breve caracterização espectroscópica da proteína sobre expressa; DgFdIIrec• Finalmente, foi isolada de Desulfovibrio desulfuricans ATCC 27774, uma nova ferredoxina do tipo 2 x [4Fe-4S]. Esta proteína foi posteriormente caracterizada bioquimicamente e por espectroscopia de RMN de 10 e 20, utilizando a mesma metodologia e informação obtida para a DgFdIIint.
Junta Nacional de Investigação Científica e Tecnológica (JNICT),Fundação Luso-Americana para o Desenvolvimento(FLAD)e Fundação Calouste Gulbenkian
Marques, Marcia Renata Hidalgo. "Avaliação da gordura hepática utilizando ressonância magnética." Universidade de São Paulo, 2016. http://www.teses.usp.br/teses/disponiveis/76/76132/tde-14062016-152116/.
Full textHepatic steatosis is a disease characterized by excessive accumulation of fat in liver cells. Its incidence is increasing and it is expected to become the chronic liver disease with the highest prevalence worldwide, which became a major concern to medical and scientific community. Although considered a benign disease, fatty liver can evolve to more serious diseases such as cirrhosis, advanced fibrosis, steatohepatitis (with or without fibrosis) or carcinoma. However, it is potentially reversible, even in the most severe cases, which reinforces the urgent need to develop reliable methods for detection and evaluation, including throughout treatment. Current methods for diagnosis and measurement of liver fat are still flawed: ultrasound is not able to perform quantification; CT uses ionizing radiation; biopsy, considered the gold standard, is accurate but invasive and focal. Magnetic resonance imaging (MRI) and spectroscopy (MRS) are completely non-invasive alternatives capable of providing diagnosis and quantification of infiltrated fat in the liver. However, studies in the literature frequently employ pulse sequences especially developed for this purpose, with extremely elaborate post-processing methods, which are not compatible with the current state of the art of typical clinical scanners or even with the level of experience and knowledge of technical staff working in radiology clinics. Thus, the main goal of this study was to evaluate the potential of MRI as a candidate for diagnosing and quantifying fat liver in clinical settings, using conventional pulse sequences, acquisition and post-processing protocol, compatible with those performed in clinical examinations in both simplicity and total acquisition time. We investigated different approaches of MRI and MRS using liver biopsy as reference standard. We evaluated patients with type II diabetes, which have a high prevalence of non-alcoholic fat liver disease, and great variability in the percentage of fat. Correlation, accuracy, sensitivity and specificity measurements of each of the approaches used were performed. All evaluated methods highly correlated (> 87%) with the data obtained from invasive measurement, which shows that the values obtained using MRI are consistent with that observed for liver biopsy. Although the processing methods used are not as complex as would be required if an absolute quantification was desired, our analyzes showed high accuracy, sensitivity and specificity of MRI in the evaluation of steatosis. In conclusion, MRI is an excellent candidate to assess liver fat fraction in a non-invasive way, even when considering the limitations imposed by conventional clinical setting. This suggests that these new methods may begin to migrate to clinical environments without relying on complex sequences and exotic post-processing techniques that are described in the current literature.
Rispoli, Vinicius de Carvalho. "Simulações computacionais do escoamento cardiovascular guiadas por ressonância magnética." reponame:Repositório Institucional da UnB, 2014. http://repositorio.unb.br/handle/10482/18045.
Full textSubmitted by Ana Cristina Barbosa da Silva (annabds@hotmail.com) on 2015-02-20T17:57:17Z No. of bitstreams: 1 2014_ViniciusdeCarvalhoRispoli.pdf: 16939736 bytes, checksum: 8dfa17c58667403d827192cadef858c7 (MD5)
Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2015-04-29T21:10:38Z (GMT) No. of bitstreams: 1 2014_ViniciusdeCarvalhoRispoli.pdf: 16939736 bytes, checksum: 8dfa17c58667403d827192cadef858c7 (MD5)
Made available in DSpace on 2015-04-29T21:10:38Z (GMT). No. of bitstreams: 1 2014_ViniciusdeCarvalhoRispoli.pdf: 16939736 bytes, checksum: 8dfa17c58667403d827192cadef858c7 (MD5)
As doenças cardiovasculares representam hoje uma das maiores causas de morte no mundo. Desta forma, o conhecimento dos padrões de escoamento sanguíneo no corpo humano se faz importante no diagnóstico e pesquisa de algumas doenças. Utilizando a ressonância magnética (RM), o escoamento sanguíneo pode ser mensurado in vivo diretamente usando ressonância magnética (RM) com contraste de fase (CF) ou através da codificação de velocidade em Fourier (CVF). Por outro lado, o escoamento sanguíneo pode também ser simulado utilizando uma abordagem baseada em modelos da dinâmica dos fluidos computacional (DFC). O CF tem como desvantagens os longos tempos de aquisição, a resolução espaço-temporal limitada, efeitos de volume parcial e baixa relação sinal-ruído (SNR). Por outro lado, a codificação de velocidade em Fourier é um método de imageamento por ressonância magnética promissor para realizar medidas do escoamento cardiovascular. A CVF oferece SNR consideravelmente maior que o CF e também é robusto aos efeitos de volume parcial. Os conjuntos de dados com CVF são adquiridos com baixa resolução espacial devido aos longos tempos de aquisição relacionados a sua alta dimensionalidade, (x,y,v,t), mas proporcionam a distribuição de velocidade associada a cada um dos seus grandes voxels. Entretanto, não um mapa de velocidades do escoamento. Finalmente, a DFC proporciona alta resolução temporal e espacial, além de tempos de aquisição reduzidos. Porém a sua acurácia é dependente das hipóteses do modelo. O objetivo deste trabalho é apresentar um método capaz de integrar medidas diretas de RM (CF ou CVF) a um algoritmo para determinar solução das equações da dinâmica dos fluidos, tendo como principal interesse a redução no tempo de exame num ambiente clínico. Desta forma, este trabalho apresenta duas contribuições originais: (i) um método para extrair mapas de velocidade de alta resolução espacial a partir de dados com CVF de baixa resolução espacial; e (ii) um método para reconstruir campos de velocidade que são influenciados ao mesmo tempo pelas medidas diretas por RM (CF ou CVF) e pelos modelos físicos da dinâmica dos fluidos. _________________________________________________________________________________ ABSTRACT
Cardiovascular diseases represents today one of the leading causes of death worldwide. Thus, knowledge of the blood flow patterns in the human body is important for diagnosis and research of certain diseases. Using magnetic resonance (MRI), in vivo 3D blood flow patterns can be either measured directly using phase–contrast (PC) MRI or Fourier velocity encoding (FVE) MRI. On the other hand, blood flow patterns can be obtained from model-based computational fluid dynamics (CFD) calculations. PC–MRI suffers from long scan times, limited spatio–temporal resolution, partial–volume effects and low signal–to–noise ratio (SNR). Fourier velocity encoding (FVE) is a promising magnetic resonance imaging method for measurement of cardiovascular blood flow. FVE provides considerably higher SNR than phase contrast imaging, and is robust to partial–volume effects. FVE data is usually acquired with low spatial resolution, due to scantime restrictions associated with its higher dimensionality, (x; y; v; t), and provides the velocity distribution associated with a large voxel, but does not directly provides a velocity map. Since the acquisition time is a disadvantage of FVE, then, preferably, it should be acquired with rapid spiral trajectories. Finally, CFD provides arbitrarily high spatial and temporal resolution and reduced scan times, but its accuracy hinges on the model assumptions. The objective of this work is to present a method capable of integrate direct MRI (PC or FVE) measures inside a CFD solver on the way to reduce scan time in a clinical environment. This work presents two main original contributions: (i) a method to derive velocity maps with high spatial resolution from low spatial resolution FVE data; and (ii) a numerical framework for constructing a flow field that is influenced by both direct measurements (PC–MRI or FVE) and a fluid physics model.
Senzako, Edna Yoshiko. "SisMatch - Matching para Imagens de Tomografia por Ressonância Magnética." Universidade de São Paulo, 1996. http://www.teses.usp.br/teses/disponiveis/55/55134/tde-28082017-091429/.
Full textThis work presents a study of image matching. Image matching can be used to evaluate the similarþ between objects in different images, to detect change between scenes, to calculate movement of objects and to compile information from different kind of images. This project was based on a theoretical study of matching, the implementation of SísMatch - System of Matching and the analysis of perfonnance of the -matching methods. The images are delivered by the Magnetic Resonance tomograph under development at Physics Institute at São Carlos - USP.
Books on the topic "Elastografia por Ressonância Magnética"
William, Oldendorf, ed. Basics of magnetic resonance imaging. Boston: M. Nijhoff, 1988.
Find full textRic, Harnsberger H., ed. Handbook of head and neck imaging. 2nd ed. St. Louis: Mosby, 1995.
Find full textHarnsberger, H. Ric. Handbook Of Head And Neck Imaging: Handbooks in Radiology Series (Handbooks in Radiology). 2nd ed. Mosby, 1994.
Find full textBook chapters on the topic "Elastografia por Ressonância Magnética"
Silva, Amanda Alves, Yasmim Machado Chaves de Castro, Anna Carolina Maia Mata Hermida, Carolina Souza de Melo, Ylanna Fortes Fonseca, Nelma Pereira de Santana, André Castro Lyra, Fernanda Dias Gonzalez, Thais Dias Gonzalez, and Lourianne Nascimento Cavalcante. "AVALIAÇÃO DA FIBROSE NA DOENÇA HEPÁTICA GORDUROSA NÃO ALCOÓLICA PELA ELASTOGRAFIA HEPÁTICA POR RESSONÂNCIA MAGNÉTICA." In Práticas Preventivas e Práticas Curativas na Medicina, 55–64. Atena Editora, 2021. http://dx.doi.org/10.22533/at.ed.6562103036.
Full textCosta, Victor Lemos, Amanda Alves Silva, Anna Carolina Maia Mata Hermida, Carolina Souza de Melo, Yasmim Machado Chaves de Castro, Ylanna Fortes Fonseca, Nelma Pereira de Santana, et al. "PERFIL CLÍNICO-EPIDEMIOLÓGICO DOS PACIENTES QUE REALIZARAM ELASTOGRAFIA HEPÁTICA POR RESSONÂNCIA MAGNÉTICA EM CENTRO DE REFERÊNCIA EM SALVADOR-BA." In Práticas Preventivas e Práticas Curativas na Medicina, 164–76. Atena Editora, 2021. http://dx.doi.org/10.22533/at.ed.65621030316.
Full text"Ressonância magnética das mamas." In PRORAD Programa de Atualização em Radiologia e Diagnóstico por Imagem : Ciclo 11 : Volume 1. 10.5935, 2021. http://dx.doi.org/10.5935/978-65-5848-353-3.c0003.
Full textConference papers on the topic "Elastografia por Ressonância Magnética"
Helton Rios, Edmilson, Giovanni Chaves Stael, Paulo Frederico de Oliveira Ramos, Vinicius de França Machado, Ruan Barbosa Forecchi, and Rodrigo Bagueira de Vasconcellos Azeredo. "Caracterização Petrofísica De Rochas Reservatório Por Ressonância Magnética Nuclear." In IV Simpósio Brasileiro de Geofísica. European Association of Geoscientists & Engineers, 2010. http://dx.doi.org/10.3997/2214-4609-pdb.197.sbgf_2414.
Full textHelton Rios, Edmilson, Giovanni Chaves Stael, Paulo Frederico de Oliveira Ramos, Vinicius de França Machado, Ruan Barbosa Forecchi, and Rodrigo Bagueira de Vasconcellos Azeredo. "Caracterização Petrofísica De Rochas Reservatório Por Ressonância Magnética Nuclear." In IV Simpósio Brasileiro de Geofísica. European Association of Geoscientists & Engineers, 2010. http://dx.doi.org/10.3997/2214-4609-pdb.197.sbgf_2458.
Full textHelton Rios, Edmilson, Giovanni Chaves Stael, Paulo Frederico de Oliveira Ramos, Vinicius de França Machado, Ruan Barbosa Forecchi, and Rodrigo Bagueira de Vasconcellos Azeredo. "Caracterização petrofísica de rochas reservatório por Ressonância Magnética Nuclear." In Simpósio Brasileiro de Geofísica. Sociedade Brasileira de Geofísica, 2010. http://dx.doi.org/10.22564/4simbgf2010.166.
Full textPinho, K. E. P., P. M. Gewehr, A. C. Pinho, A. M. Gusso, and C. A. Goedert. "APLICAÇÃO DE IMAGE J® PARA IMAGENS EM COLANGIOPANCREATOGRAFIA POR RESSONÂNCIA MAGNÉTICA." In Congresso Brasileiro de Eletromiografia e Cinesiologia (COBEC) e o Simpósio de Engenharia Biomédica (SEB) - COBECSEB. Uberlândia, Minas Gerais: Even3, 2018. http://dx.doi.org/10.29327/cobecseb.78965.
Full textBastos Schuab, Frederico, Alessandra Winter, and Osvair Vidal Trevisan. "Caracterização de carbonatos bimodais integrando Pressão Capilar por Mercúrio e Ressonância Magnética Nuclear." In Simpósio Brasileiro de Geofísica. Sociedade Brasileira de Geofísica, 2014. http://dx.doi.org/10.22564/6simbgf2014.066.
Full textAlves, A. L., T. M. Izoton, M. R. Velloso, F. L. Partelli, M. S. Pessoa, and P. Moscon. "Determinação de Ácidos Graxos em Genótipos de Cafés (Coffea canephora) por Ressonância Magnética Nuclear." In IX Encontro Científico de Física Aplicada. São Paulo: Editora Blucher, 2018. http://dx.doi.org/10.5151/ecfa2018-16.
Full textFarias, Valcir J. da C., Marcus P. C. da Rocha, Heliton R. Tavares, and Alessandra L. de Oliveira. "Pré-Processamento de Dados de Imagem Funcional por Ressonância Magnética Usando o Filtro de Kalman." In XXXV CNMAC - Congresso Nacional de Matemática Aplicada e Computacional. SBMAC, 2015. http://dx.doi.org/10.5540/03.2015.003.01.0466.
Full textFaleiros, Matheus Calil, José Raniery Ferreira Junior, Eddy Javala Jens, Vitor Faeda Dalto, Marcello Henrique Nogueira-Barbosa, and Paulo Mazzoncini De Azevedo-Marques. "Reconhecimento Computadorizado de Padrões Inflamatórios de Sacroiliíte em Imagens de Ressonância Magnética." In XVII Simpósio Brasileiro de Computação Aplicada à Saúde. Sociedade Brasileira de Computação - SBC, 2017. http://dx.doi.org/10.5753/sbcas.2017.3731.
Full textHoerlle, Fernanda O., William G. A. L. Silva, Edmilson H. Rios, Maira C. O. Lima, Elizabeth M. B. D. Pontedeiro, José L. D. Alves, and Paulo Couto. "Caracterização por ressonância magnética nuclear do sistema poroso de coquinas da Formação Morro do Chaves, Bacia Sergipe-Alagoas." In Simpósio Brasileiro de Geofísica. Brazilian Geophysical Society, 2018. http://dx.doi.org/10.22564/8simbgf2018.096.
Full textBraga, Mateus Figueiredo, Rui de Barros Correia-Filho, and Jorge Luiz Silva Araujo-Filho. "A IMPORTÂNCIA DE EXAMES DE IMAGEM EM PACIENTES COM TOXOPLASMOSE CEREBRAL E DIAGNÓSTICO DE AIDS: REVISÃO BIBLIOGRÁFICA." In I Congresso Brasileiro de Parasitologia Humana On-line. Revista Multidisciplinar em Saúde, 2021. http://dx.doi.org/10.51161/rems/710.
Full text