To see the other types of publications on this topic, follow the link: Electric power transmission – Nigeria.

Dissertations / Theses on the topic 'Electric power transmission – Nigeria'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 50 dissertations / theses for your research on the topic 'Electric power transmission – Nigeria.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.

1

Okafor, Chukwuemeka. "Electricity generation, transmission and distribution policy: a comparative study of Nigeria (1960-2011) and South Africa (1960-2011)." Thesis, University of Fort Hare, 2013. http://hdl.handle.net/10353/d1007049.

Full text
Abstract:
The electric power policies in Nigeria and South Africa are considered the governments’ intention to provide quality and affordable electricity to the people. A comparative study on the electric power policies focuses on the similarities and differences in the policy approaches, the policy issues that affect electrification, and the impact of the policy issues in achieving the goal of universal access to quality and affordable electricity power in both countries. The methodological approach allows for an in depth textual study on the electric power policy documents in both countries. In Nigeria, the government intends to address the massive demand-supply imbalance and achieve the goal of electrification through reforms that focus on private sector-led growth in the sub-sector. In South Africa, the identification of electrification as a public problem by the post apartheid government leads to an integrated policy framework that focuses on balancing economic concerns with social and environmental considerations. The study identifies electricity provision as a social welfare responsibility of the governments in both countries and examines the policy issues in the context of public welfare. In Nigeria, the policy issues are found to be self serving and not in line with sustainable public interest, given the socio-economic challenges. As a result they, exert less impact on achieving the goal of universal access to quality and affordable electricity in the country. In South Africa, good governance in the sub-sector has enabled the identification of policy issues in line with sustainable public interests of social equity, poverty alleviation and environmental sustainability; and government using public administration agencies to play a key role in service delivery. Recommendations of the study mainly derive from the South African experience on electrification, and are intended to offer some policy-lessons to Nigeria in the sub-sector. The study contributes to new knowledge in the discipline of public administration by opening up new vistas for a comparative analysis of electric power policy issues in both countries in the context of public welfare. Besides, a comparative study on electrification in Nigeria and South Africa from a policy angle contributes to the existing knowledge base in the discipline.
APA, Harvard, Vancouver, ISO, and other styles
2

Shaaban, Mohamed Mohamed Abdel Moneim. "Calculation of available transfer capability of transmission networks including static and dynamic security." Thesis, Click to view the E-thesis via HKUTO, 2002. http://sunzi.lib.hku.hk/hkuto/record/B42576817.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Lee, Cheuk-wing. "Transmission expansion planning in a restructured electricity market." Click to view the E-thesis via HKUTO, 2007. http://sunzi.lib.hku.hk/hkuto/record/B38959410.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Sozer, Sevin Park Chan S. "Transmission expansion planning to alleviate congestion in deregulated power markets." Auburn, Ala., 2006. http://repo.lib.auburn.edu/Send%206-15-07/SOZER_SEVIN_35.pdf.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Yu, Chang. "An investigation of subsynchronous oscillation of AC/DC power systems modeling and analysis /." Click to view the E-thesis via HKUTO, 2006. http://sunzi.lib.hku.hk/hkuto/record/B37151885.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Salem, M. M. "Two level state estimation for large electric power systems." Thesis, University of Strathclyde, 1985. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.372189.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Zhang, Xiaodong. "Power system transmission enhancement through storage." Thesis, This resource online, 1992. http://scholar.lib.vt.edu/theses/available/etd-11242009-020211/.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Radibratovic, Branislav. "Reactive optimization of transmission and distribution networks." Diss., Atlanta, Ga. : Georgia Institute of Technology, 2008. http://hdl.handle.net/1853/28264.

Full text
Abstract:
Thesis (M. S.)--Electrical and Computer Engineering, Georgia Institute of Technology, 2009.
Committee Chair: Begovic, Miroslav; Committee Member: Divan, Deepakraj; Committee Member: Dorsey, John; Committee Member: Ferri, Bonnie; Committee Member: Lambert, Frank.
APA, Harvard, Vancouver, ISO, and other styles
9

Zabel, D. F. "Structure-borne sound transmission within electric power steering systems." Thesis, University of Salford, 2018. http://usir.salford.ac.uk/48186/.

Full text
Abstract:
Transfer path analysis (TPA) is an established and valuable tool in the automotive industry, to determine the contributions of structure-borne sound sources to receiver responses at target positions. The classical TPA approach is based on contact forces at the interface between source and receiver to characterise the dynamic loads induced by the source and frequency response functions (FRFs) to quantify the transfer paths of the sound from the interface locations to the target positions. With knowledge of the determined contributions it is then possible to decide whether source loads or FRFs must be improved to optimise the target quantities. Recently a timesaving improvement to classical TPA has been proposed, where the loads are characterised using the in-situ blocked force method, so that dismantling of source and receiver is not necessary. This method is therefore called in-situ TPA. However, if the contributions of internal structure-borne sound sources to the overall vibro-acoustic behaviour of a product are desired it is of benefit if the target quantities are blocked forces. Thus it would be possible to virtually couple the product with the properties of an overall receiver. Therefore this thesis presents a TPA approach called “blocked force transmissibility transfer path analysis” (bfTPA). In this context, the proposed internal-source-path-receiver-model (ISPRM) poses the theoretical basis of bfTPA. The aim of the presented novel TPA is to determine the contribution of internal structure-borne sound sources to an overall target quantity of a product. The presented approach uses the vector of in-situ blocked forces measured externally at the contact interface of the overall product and a corresponding set of “blocked force transmissibility” (BFT) functions relating the external coupling degrees of freedom (DOFs) to the internal source DOFs in order to propagate the external in-situ blocked forces back to multiple internal in-situ blocked forces. To prove the methodology of the presented approach three case studies, which increase in complexity, were carried out experimentally. The case studies concern a beam and an electric power steering system with paraxial servo unit (EPSapa), respectively. EPSapa systems consist of multiple embedded vibrational components which are defined as “internal sources”. The electric motor, the ball nut assembly and the toothed belt are identified as the main internal sources of an EPSapa system. Hence they are characterised by means of experimentally determined blocked forces. For the determination, micro electro mechanical systems (MEMS) accelerometers are embedded at the so called “internal interfaces”. This poses a novel application of the in-situ method in combination with the dealing of continuous and revolving internal interfaces. Concluding a further application of the bfTPA methodology is presented. It allows the external in-situ blocked forces of EPS systems or other products to be predicted based on internal insitu blocked forces and the BFT functions within internal receivers such as housings, for instance. Hence, the proposed approach is called “virtual component assembly”. It offers the advantage to synthesize a virtual EPS system based on the in-situ blocked forces of its components which are determined on test benches.
APA, Harvard, Vancouver, ISO, and other styles
10

Yan, Yonghe, and 嚴勇河. "A multi-agent based approach to transmission cost allocation." Thesis, The University of Hong Kong (Pokfulam, Hong Kong), 2000. http://hub.hku.hk/bib/B3124256X.

Full text
APA, Harvard, Vancouver, ISO, and other styles
11

Lee, Cheuk-wing, and 李卓穎. "Transmission expansion planning in a restructured electricity market." Thesis, The University of Hong Kong (Pokfulam, Hong Kong), 2007. http://hub.hku.hk/bib/B38959410.

Full text
APA, Harvard, Vancouver, ISO, and other styles
12

Li, Xiaojuan. "Estimations of power system frequency, phasors and their applications for fault location on power transmission lines." University of Western Australia. School of Electrical, Electronic and Computer Engineering, 2008. http://theses.library.uwa.edu.au/adt-WU2008.0125.

Full text
Abstract:
The thesis is devoted to the development of new algorithms for estimation of system frequency, power system phasors and transmission line fault location in the context of power system protection and control. A z-transform signal model combined with a nonlinear post-filtering scheme to estimate the operating frequency in a power system is first developed in the thesis. The signal model parameters are identified by an optimisation method in which the error between the model output and the actual signal that represents a voltage or current in the power system is minimised. The form and the structure of the signal model do not require iterations in the optimisation process for parameter identification. The system operating frequency is directly evaluated from the model parameters. Effects of noise and any frequency components other than the operating or supply-frequency on the accuracy are countered very effectively by applying a median post-filtering on the time series representing the frequency estimates derived from the model. Extensive simulation studies and comparisons with previously-published frequency estimation techniques confirm the high performance of the method developed in the thesis in terms of accuracy and time delay. With respect to power system phasor estimation, a method is developed based on waveform interpolation in the discrete time-domain to counter the spectral leakage errors arising in forming, by discrete Fourier transform (DFT), the supply frequency phasors representing power system voltages and currents when there are system frequency deviations from the nominal value. The interpolation scheme allows DFT evaluation to be performed with a time window length which is exactly equal to the fundamental period of the voltage or current waveform. Comparative studies presented in the thesis confirm the improvements achieved by the method proposed over other previouslypublished techniques in terms of accuracy and computing time. With the availability of accurate operating frequency and phasor estimates, an optimal fault location method based on multi-conductor distributedparameter line model is developed. The method is a general one which is applicable to any transmission line configurations, including multi-terminal lines. The fault location method is based on the minimisation of an objective function in which the fault distance is a variable. The objective function is formed from combining the phase-variable distributed-parameter equations of individual line sections from the fault point to the line terminals. The multivariable minimisation leads to high accuracy and robustness of the fault location algorithm in which any voltage/current measurement errors, including sampling time synchronisation errors, are represented in the estimation procedure as variables in addition to the fault distance. Extensive simulation studies are performed to verify that the method developed is highly accurate and robust. The thesis is supported by two international publications of which the candidate is a joint author.
APA, Harvard, Vancouver, ISO, and other styles
13

Matevosyan, Julija. "Wind Power Integration in Power Systems with Transmission Bottlenecks." Doctoral thesis, Stockholm, 2006. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-4108.

Full text
APA, Harvard, Vancouver, ISO, and other styles
14

Cordero, Roberto. "Estimation of transmission losses in a changing electric power industry." Thesis, Massachusetts Institute of Technology, 1996. http://hdl.handle.net/1721.1/39395.

Full text
APA, Harvard, Vancouver, ISO, and other styles
15

Westerlund, Per. "Condition measuring and lifetime modelling of electrical power transmission equipment." Licentiate thesis, KTH, Elektroteknisk teori och konstruktion, 2015. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-167136.

Full text
Abstract:
The electric grid is important in modern society, so the outages should be few. The transmission grid should have a real high availability, since it transports electrical energy across the country. Then, it is difficult to plan outages for maintenance and installation. This thesis lists twenty surveys about failures of circuit breakers and disconnectors, with data about the cause and the lifetime. It also contains a survey of about forty condition-measuring methods for circuit breakers and disconnectors, mostly applicable to the electric contacts and the mechanical parts. As there is no published method to monitor the electric contacts at voltages around 400 kV, a system with IR sensors has been installed at the nine contacts of six disconnectors. The purpose is to avoid outages for maintenance by estimating the condition of the contacts while the disconnectors are still connected to high voltage. The measured temperatures are collected by radio and regressed against the square of the current, since the best exponent for the current was found to be 2.0. The coefficient of determination $R^2$ is high, greater than 0.9. This gives for each contact a regression coefficient, which can serve as an estimate of the condition of the contact. The higher the coefficient is, the more heat is produced at the contact, which can damage the material. This enables a ranking of the different contacts and shows which the worst ones are. This coefficient can also give a dynamic rating of the disconnector.
Elnätet är viktigt i det moderna samhället, så antalet avbrott bör vara lågt. Särskilt stamnätet bör ha en särskilt hög tillgänglighet, då det transporterar elektrisk energi tvärsöver landet. Då blir det svårt att planera avbrott för underhåll och utbyggnad. Denna avhandling tar upp tjugo studier av fel i brytare och frånskiljare med data om felorsak och livslängd. Den har också en översikt av ett fyrtiotal olika metoder för tillståndsmätningar för brytare och frånskiljare, som huvudsakligen rör de elektriska kontakterna och de mekaniska delarna. Eftersom det inte finns någon beskriven metod för att övervaka elektriska kontakter för spänningar på runt 400 kV, har ett system med IR sensorer installerats på de nio kontakterna på sex frånskiljare. Målet är att minska antalet avbrott för underhåll genom att skatta skicket hos kontakterna, när frånskiljarna fortfarande är kopplade till högspänning. De uppmätta temperaturerna tas emot genom radio och behandlas genom regression mot kvadraten av strömmen, då den bästa exponenten för strömmen visade sig vara 2,0. Förklaringsfaktorn $R^2$ är hög, över 0,9. För varje kontakt ger det en regressionskoefficient, som blir en skattning av kontaktens skick. Ju högre koefficienten är, desto mer värme utvecklas det i kontakten, vilket kan leda till skador på materialet. Kontakternas olika koefficienter ger en rankordning dem och därmed en möjlighet att prioritera vilken frånskiljare som ska underhållas först. Systemet kan också användas för att minska eller öka den tillåtna strömmen baserat på skicket.

QC 20150522

APA, Harvard, Vancouver, ISO, and other styles
16

Tang, Yousin. "Power system stability in the presence of FACTS elements." Diss., Georgia Institute of Technology, 1995. http://hdl.handle.net/1853/13432.

Full text
APA, Harvard, Vancouver, ISO, and other styles
17

Wei, Ping. "A comprehensive approach to transmission pricing and its applications /." Hong Kong : University of Hong Kong, 2002. http://sunzi.lib.hku.hk/hkuto/record.jsp?B23765926.

Full text
APA, Harvard, Vancouver, ISO, and other styles
18

Kalyani, Radha Padma. "A nonlinear optimization approach for UPFC power flow control and voltage security." Diss., Rolla, Mo. : University of Missouri-Rolla, 2007. http://scholarsmine.mst.edu/thesis/pdf/Kalyani_completeThesis_09007dcc80438f59.pdf.

Full text
Abstract:
Thesis (Ph. D.)--University of Missouri--Rolla, 2007.
Vita. The entire thesis text is included in file. Title from title screen of thesis/dissertation PDF file (viewed November 29, 2007) Includes bibliographical references.
APA, Harvard, Vancouver, ISO, and other styles
19

Guldbrand, Anna. "Analysis of an induction regulator for power flow control in electric power transmission systems." Thesis, Linköping University, The Department of Physics, Chemistry and Biology, 2005. http://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-5329.

Full text
Abstract:

Controlling the power flow in transmission systems has recently gained increased interest. The difficulties of building new lines and the pressure of having a high utilization of existing assets, makes the flexibility of grid systems increasingly important.

This master thesis work investigates induction regulators as control devices for active power flow in a transmission system. A small change in angle of the rotor affects both the amplitude and the phase of the voltage. The magnetic coupling in the induction regulator can be controlled by changing the permeability of a thermo magnetic material such as gadolinium and can hence give a second independent controlling parameter. An analytical model and calculations in the

FEM software AceTripleC together with Matlab, is used to simulate the influence of the regulators connected to a simple grid in case1, a 400 kV scenario and case 2, a 45 kV scenario.

The analysis was carried out on a small transmission system consisting of two parallel transmission lines connected to source and load. The induction regulators are connected to one of the parallel transmission lines. The regulators modelled in case 1 must be able to control the active power flow in the regulated line to vary between 50 and 150 % of the original power flow through this line.

This shall be done over a range of 0 to 800 MW transmitted power. The regulators modelled in case 2 must be able to control the active power flow in

the regulated line to vary between 0 and 30 MW, if this does not cause the power flow in the parallel line to exceed 30 MW. This shall be done over a range of 0 to

50 MW transmitted power.

The regulators are designed as small and inexpensive as possible while still fulfilling requirements regarding the active power flow controllability in the grid, current density in windings and maximum flux density in core and gap.

The results indicate that the size of the 400 kV solution has to be reduced to become competitive whereas for the 45 kV solution the relative difference to existing solution is smaller. Advantages with the proposed design over a phase shifting transformer are mainly a simpler winding scheme and the absence of a tap changer.

APA, Harvard, Vancouver, ISO, and other styles
20

Kirby, Chris. "Generation participation factors and transmission costing." Thesis, National Library of Canada = Bibliothèque nationale du Canada, 1998. http://www.collectionscanada.ca/obj/s4/f2/dsk1/tape11/PQDD_0029/MQ47426.pdf.

Full text
APA, Harvard, Vancouver, ISO, and other styles
21

Gopinathan, Muraleedharan 1953. "Incentive structures for electric power transmission investment in a deregulated environment." Thesis, Massachusetts Institute of Technology, 2003. http://hdl.handle.net/1721.1/91780.

Full text
APA, Harvard, Vancouver, ISO, and other styles
22

Hasanović, Amer. "A simulation and analysis toolbox for power systems and genetic algorithm based damping controller design." Morgantown, W. Va. : [West Virginia University Libraries], 2001. http://etd.wvu.edu/templates/showETD.cfm?recnum=2173.

Full text
Abstract:
Thesis (M.S.)--West Virginia University, 2001.
Title from document title page. Document formatted into pages; contains viii, 73 p. : ill. Includes abstract. Includes bibliographical references (p. 71-73).
APA, Harvard, Vancouver, ISO, and other styles
23

Smith, Mark Allen. "Improved dynamic stability using FACTS devices with phasor measurement feedback /." This resource online, 1994. http://scholar.lib.vt.edu/theses/available/etd-05022009-040702/.

Full text
APA, Harvard, Vancouver, ISO, and other styles
24

Chan, Morgan Hing-Lap. "Communication channel characteristics and behaviour of intrabuilding power distribution circuits." Thesis, University of British Columbia, 1985. http://hdl.handle.net/2429/25081.

Full text
Abstract:
Intrabuilding power distribution circuits offer a number of unique advantages for local area networking. To enable the selection of proper error-control codes and protocols for reliable data communication services, error pattern statistics of intrabuilding power line channels are obtained. Also, error-causing disturbances are identified and their relationships to specific types of error patterns are determined. It is found that error occurrence is highly periodic, with periodicity being a function of the power line frequency which is nominally 60Hz in North America. Furthermore, results indicate that error pattern behaviour is relatively insensitive to communication carrier frequency and modulation schemes. Based on the measurement results, hybrid ARQ with bit-interleaving is suggested for reliable data transmission at high data rate (19,200bps). Burst error correcting codes can be used to reduce decoder cost and complexity with some sacrifices in performance. At lower data rates (1,200bps or below), effective error control can be accomplished more easily. Finally, the attenuation characteristics of a number of typical power line channels are presented. It is found that high frequency bypass can be used to improve signal transmission between different phases of the distribution transformer.
Applied Science, Faculty of
Electrical and Computer Engineering, Department of
Graduate
APA, Harvard, Vancouver, ISO, and other styles
25

Jones, Peter Gibson. "Evaluation of Voltage Instability Countermeasures in Constrained Sub-transmission Power Networks." PDXScholar, 2012. https://pdxscholar.library.pdx.edu/open_access_etds/112.

Full text
Abstract:
This paper investigates the various parameters that effect voltage stability in sub-transmission power networks. The paper first looks at contributions from equipment: generators, transmission lines, transformers, capacitors, SVCs and STATCOMs. The paper also looks at the effects of loads on voltage stability. Power flow solutions, PV and VQ curves are covered. The study models an existing voltage problem i.e., a long, radial, 115 kV sub-transmission network that serves a 65 MW load. The network model is simulated with the following voltage instability countermeasures: adding a capacitor, adding an SVC, adding a STATCOM, tying to a neighboring transmission system, adding generation and bringing in a new 230 kV source. Then, using the WECC heavy-winter 2012 power flow base case and Siemens PTI software, VQ and PV curves are created for each solution. Finally, the curves are analyzed to determine the best solution.
APA, Harvard, Vancouver, ISO, and other styles
26

Eriksson, Robert. "Security-centered Coordinated Control in AC/DC Transmission Systems." Licentiate thesis, Stockholm : Royal Institute of Technology, 2008. http://kth.diva-portal.org/smash/record.jsf?searchId=4&pid=diva2:101.

Full text
APA, Harvard, Vancouver, ISO, and other styles
27

Perninge, Magnus. "Modeling the Uncertainties Involved in Net Transmission Capacity Calculation." Licentiate thesis, Stockholm : Skolan för elektro- och systemteknik, Kungliga Tekniska högskolan, 2009. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-10392.

Full text
APA, Harvard, Vancouver, ISO, and other styles
28

Cecchi, Valentina Miu Karen Nan. "A modeling approach for electric power transmission lines in the presence of non-fundamental frequencies/." Philadelphia, Pa. : Drexel University, 2008. http://hdl.handle.net/1860/2583.

Full text
APA, Harvard, Vancouver, ISO, and other styles
29

Leedy, Aleck Wayne Nelms R. M. "Analysis of DC power systems containing induction motor-drive loads." Auburn, Ala., 2006. http://repo.lib.auburn.edu/2006%20Spring/doctoral/LEEDY_ALECK_32.pdf.

Full text
APA, Harvard, Vancouver, ISO, and other styles
30

Setréus, Johan. "On Reliability Methods Quantifying Risks to Transfer Capability in Electric Power Transmission Systems." Licentiate thesis, KTH, Electromagnetic Engineering, 2009. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-10258.

Full text
Abstract:

In the operation, planning and design of the transmission system it is of greatest concern to quantify the reliability security margin to unwanted conditions. The deterministic N-1 criterion has traditionally provided this security margin to reduce the consequences of severe conditions such as widespread blackouts. However, a deterministic criterion does not include the likelihood of different outage events. Moreover, experience from blackouts shows, e.g. in Sweden-Denmark September 2003, that the outages were not captured by the N-1 criterion. The question addressed in this thesis is how this system security margin can be quantified with probabilistic methods. A quantitative measure provides one valuable input to the decision-making process of selecting e.g. system expansions alternatives and maintenance actions in the planning and design phases. It is also beneficial for the operators in the control room to assess the associated security margin of existing and future network conditions.

This thesis presents a method that assesses each component's risk to an insufficient transfer capability in the transmission system. This shows on each component's importance to the system security margin. It provides a systematic analysis and ranking of outage events' risk of overloading critical transfer sections (CTS) in the system. The severity of each critical event is quantified in a risk index based on the likelihood of the event and the consequence of the section's transmission capacity. This enables a comparison of the risk of a frequent outage event with small CTS consequences, with a rare event with large consequences.

The developed approach has been applied for the generally known Roy Billinton Test System (RBTS). The result shows that the ranking of the components is highly dependent on the substation modelling and the studied system load level.

With the restriction of only evaluating the risks to the transfer capability in a few CTSs, the method provides a quantitative ranking of the potential risks to the system security margin at different load levels. Consequently, the developed reliability based approach provides information which could improve the deterministic criterion for transmission system planning.

APA, Harvard, Vancouver, ISO, and other styles
31

Naredo, V. José Luis A. "Communication frequency response of high voltage power lines." Thesis, University of British Columbia, 1987. http://hdl.handle.net/2429/26725.

Full text
Abstract:
Several methods for calculating the electrical phase and modal parameters of overhead transmission lines are described in this thesis; then, a graphical method for evaluating communication frequency response of delta transmission lines -based on the guidelines given by W. H. Senn [12,13,14]- is developed. The graphical method, combined with the parameters calculation methods, obviates the need of large mainframe computers for the analysis of power line carrier (PLC) systems. A new technique for assessing coupling alternatives, based on Senn's method, is developed. The technique is applied to generate coupling recommendations; it is found that many of the current recommendations given elsewhere [21] are not reliable. Finally, future work to be done in this field is proposed.
Applied Science, Faculty of
Electrical and Computer Engineering, Department of
Graduate
APA, Harvard, Vancouver, ISO, and other styles
32

Ferreira, Kurt Josef. "Fault location for power transmission systems using magnetic field sensing coils." Link to electronic thesis, 2007. http://www.wpi.edu/Pubs/ETD/Available/etd-050707-120755/.

Full text
APA, Harvard, Vancouver, ISO, and other styles
33

Li, Quan. "AC loss characteristics of monolayer and multilayer superconducting power transmission cables." Thesis, University of Cambridge, 2011. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.609500.

Full text
APA, Harvard, Vancouver, ISO, and other styles
34

Hasanovic, Azra. "Modeling and control of the unified power flow controller (UPFC)." Morgantown, W. Va. : [West Virginia University Libraries], 2000. http://etd.wvu.edu/templates/showETD.cfm?recnum=1633.

Full text
Abstract:
Thesis (M.S.)--West Virginia University, 2000.
Title from document title page. Document formatted into pages; contains viii, 78 p. : ill. Includes abstract. Includes bibliographical references (p. 61-63).
APA, Harvard, Vancouver, ISO, and other styles
35

Sternberger, Ronny. "Analytical modelling and controller design of a multilevel STATCOM." Thesis, Available from the University of Aberdeen Library and Historic Collections Digital Resources, 2009. http://digitool.abdn.ac.uk:80/webclient/DeliveryManager?application=DIGITOOL-3&owner=resourcediscovery&custom_att_2=simple_viewer&pid=25797.

Full text
APA, Harvard, Vancouver, ISO, and other styles
36

Kumbale, Murali. "Bulk transmission system reliability analysis of protection and control groups." Thesis, Georgia Institute of Technology, 1996. http://hdl.handle.net/1853/13840.

Full text
APA, Harvard, Vancouver, ISO, and other styles
37

Fitton, Colin Robert. "Mathematical modelling of balanced and unbalanced HVDC power transmission links." Thesis, Loughborough University, 1988. https://dspace.lboro.ac.uk/2134/9033.

Full text
Abstract:
In high voltage direct current power transmission, the need to filter the non-sinusoidal current wave forms drawn by the converters from the ac supply has long been acknowledged. Assessment of the harmonic content of these waveforms to the best accuracy possible is a desirable objective to aid filter design. The conventional analytical technique necessitates making simplifying assumptions and produces only approximate results. Such practical considerations as system unbalance cannot be taken into account. The objective of the research was to perform in-depth analyses of hvdc transmission links, by developing a mathematical model which, in addition to perfectly balanced conditions, allows for the following practical operational abnormalities: (i) Unbalanced 3-phase ac supply voltages (ii) Unbalanced converter transformer impedances (iii) Asymmetrical thyristor valve triggering, whilst not making the usual assumptions of infinite dc side inductance and zero ac system impedance. In other words to develop a completely comprehensive mathematical model. The initial approach was to develop the tensor analysis of a six-pulse Graetz bridge supplied first by a star-star, and then by a star-delta connected transformer. A twelve-pulse converter system was then investigated by modelling the series connection of these two arrangements. The technique of diakoptlcs was introduced and combined with the previous tensor analysis to model a complete dc link with a twelve pulse converter at each end of a transmission line. The diakoptic approach enables the full circuit to be torn, for the purpose of the analysis, into the two twelve pulse converters and the dc line. Summary The final stage of the development of the model involved the inclusion of a more sophisticated representation of the ac system impedance and the addition of tuned or damped filters at the ac busbars. To verify the program, computed results from the mathematical model are compared with corresponding experimental results obtained from a laboratory-scale model of a typical hvdc link configuration. Comparisons are also made with conventionally based calculations involving the assumptions included in the computer-based results, in order to investigate the relative accuracy of the computed solution.
APA, Harvard, Vancouver, ISO, and other styles
38

Ng, Kwok-kei Simon. "A game-theoretic study of the strategic interaction between transmission and generation expansion planning in a restructured electricity market." Click to view the E-thesis via HKUTO, 2007. http://sunzi.lib.hku.hk/hkuto/record/B39343534.

Full text
APA, Harvard, Vancouver, ISO, and other styles
39

Crnojacki, Zorica. "Extra high voltage transmission corridor siting : technical, public, institutional and regulatory considerations /." Diss., This resource online, 1994. http://scholar.lib.vt.edu/theses/available/etd-10032007-171749/.

Full text
APA, Harvard, Vancouver, ISO, and other styles
40

Yu, Chang, and 余暢. "An investigation of subsynchronous oscillation of AC/DC power systems: modeling and analysis." Thesis, The University of Hong Kong (Pokfulam, Hong Kong), 2006. http://hub.hku.hk/bib/B37151885.

Full text
APA, Harvard, Vancouver, ISO, and other styles
41

Miyasaka, Juro. "Study on Microwave-Driven Electric Vehicle for Agriculture." Kyoto University, 2014. http://hdl.handle.net/2433/188749.

Full text
Abstract:
Kyoto University (京都大学)
0048
新制・論文博士
博士(農学)
乙第12823号
論農博第2796号
新制||農||1025(附属図書館)
学位論文||H26||N4818(農学部図書室)
31310
京都大学農学研究科農業工学専攻
(主査)教授 清水 浩, 教授 近藤 直, 教授 飯田 訓久
学位規則第4条第2項該当
APA, Harvard, Vancouver, ISO, and other styles
42

Tasie, Oyinkansola. "Expanding access to electricity for sustainable development in Nigeria : an analysis of the Electric Power Sector Reform Act 2005." Thesis, University of Aberdeen, 2014. http://digitool.abdn.ac.uk:80/webclient/DeliveryManager?pid=210754.

Full text
Abstract:
The importance of modern energy services to development is well established and it extends to deploying renewable energy for electricity to address current global challenges such as lack of access to electricity, poverty, environmental degradation and climate change. No doubt, electricity from renewable energy has negative impacts, but it also has benefits over other energy sources, particularly coal, oil and gas. These benefits have included that it is generally environmentally benign, it is vast, free, and supports standalone technologies. Thus avoiding costs associated with expanding the grid network. Hence, the idea that enhanced deployment of renewable energy for electricity can drive sustainable development in countries such as Nigeria, where amidst global concerns about climate change, modern access to electricity is low and energy supply for basic tasks such as cooking and cooling are from energy sources harnessed unsustainably or is itself not sustainable. In addition, other problems in Nigeria include high poverty and unemployment rates, environment degradation, destruction of biodiversity and natural ecosystem, corruption, lack of infrastructure, and dwindling government revenue profiles. Yet, the country has significant energy resources, renewables and non-renewables through which it can presumably meet all its energy needs. Nigeria enacted the Electric Power Sector Reform Act (EPSRA) in March 2005 to give statutory support to its National Electric Power Policy, (NEPP) which, inter alia, sought to promote expanded access to electricity, with minimum adverse impact on the environment. Given the benefits of renewable electricity, and the policy objectives on electricity development in Nigeria, this thesis examines the ability of Nigeria's Electric Power Sector Reform Act (EPSRA) 2005 to enhance the deployment of renewable energy for electricity and thereby foster sustainable development in the country.
APA, Harvard, Vancouver, ISO, and other styles
43

Liu, Kai. "A decentralized congestion management approach for the multilateral energy transaction via optimal resource allocation." Click to view the E-thesis via HKUTO, 2007. http://sunzi.lib.hku.hk/hkuto/record/B38750107.

Full text
APA, Harvard, Vancouver, ISO, and other styles
44

Kirawanich, Phumin. "Fuzzy logic control for an active power line conditioner /." free to MU campus, to others for purchase, 2002. http://wwwlib.umi.com/cr/mo/fullcit?p3060114.

Full text
APA, Harvard, Vancouver, ISO, and other styles
45

Susuki, Yoshihiko. "Transient Dynamics and Stability Boundaries in Electric Power System with DC Transmission." 京都大学 (Kyoto University), 2004. http://hdl.handle.net/2433/77775.

Full text
APA, Harvard, Vancouver, ISO, and other styles
46

Mthunzi, Everett Mondliwethu. "Performance analysis of a protection scheme based on P-class synchrophasor measurements." Thesis, Cape Peninsula University of Technology, 2016. http://hdl.handle.net/20.500.11838/2378.

Full text
Abstract:
Thesis (MTech (Electrical Engineering))--Cape Peninsula University of Technology, 2016.
Power grid and system protection advancement greatly depend on technological advances. Advent technologies like digital microprocessor type protective relays facilitate paradigm shifts, providing inimitable beneficial engineering adaptations. Phasor measuring technology provides one such technological advance. The onset and rapid development of the Phasor Measuring Unit (PMU) provides an excellent platform for phasor-based, power system engineering. Power transmission constitutes a critical section in the electric power system. The power system transmission lines are susceptible to faults which require instant isolation to establish and maintain consistent system stability. This research focuses on the study of transmission line protection based on P-Class synchrophasor measurements. The IEEE C37.238-2011 Precision Time Protocol (PTP) paradigm shift facilitates practical application of synchrophasors in protection schemes. Synchrophasor procession and accurate data alignment over wide areas support the hypothesis of a phasor-based transmission line differential protection. This research aims to directly implement P-Class synchrophasors in transmission line differential protection, employing synchrophasors to determine fault conditions and administer corresponding protective actions in wide area transmission lines. The research also aims to evaluate the operational characteristics of the synchrophasor-based transmission line differential protection scheme. The research deliverables include a laboratory scale Test-bench that implements the PMU-based transmission line differential protection scheme, and a differential protection utility software solution that follows guidelines specified by the C37.118-2011 standard for synchrophasors. The findings stand to evaluate performance of the PMU-based line differential protection scheme, verifying the protection model as an alternate, practical and feasible backup protection solution. The research deliverables include a synchrophasor-based current differential algorithm, software utility for implementing the PMU-based protection scheme and a Test-bench for concept and feasibility validation.
APA, Harvard, Vancouver, ISO, and other styles
47

Lwana, Mkuseli. "Investigation of 3 terminal differential protection using standard-based numerical relays." Thesis, Cape Peninsula University of Technology, 2017. http://hdl.handle.net/20.500.11838/2578.

Full text
Abstract:
Thesis (MTech (Electrical Engineering))--Cape Peninsula University of Technology, 2017.
Transmission lines are a vital part of the electrical distribution system, as they provide the path to transfer power between generation and load. Factors like de-regulated market environment, economics, etc. have pushed utilities to operate transmission lines close to their operating limits. Any fault, if not detected and isolated quickly will cascade into a system wide disturbance causing widespread outages for a tightly interconnected system operating close to its limits. Current differential criterion is used with success to protect various elements in power systems, i.e. transmission lines, power transformers, generators and busbars. The alpha plane differential relaying system provides sensitive protection for transmission lines, security and dependability for external faults. This thesis focuses on three terminal alpha plane differential protection with the aim to develop a complete test method using OMICRON test universe software essentially defining security, dependability and sensitivity of the alpha plane characteristic. The research analyses the three terminal alpha plane characteristic and existing primitive test methods and develops an improved test method using IEC 61850 standard. The primitive methods are time consuming and result in unnecessary prolonged outages. These methods have been discussed and improved in the thesis by implementing IEC 61850 standard. First the standard IED Capability Description (ICD) file is modified by developing new logical nodes using AcSELerator Architect and XML Maker software. Then the developed logical nodes, three terminal differential protection alpha plane characteristic with its additional infeed/outfeed check logic, and the developed test method are tested simultaneously using Test Universe software. A laboratory test bench is built using three SEL311L relays, two CMC 356 Omicron injection devices, PC, MOXA switch, CMIRIG-B time synchronising unit, SEL 2407 satellite synchronised clock, and a DC power supplier. The test method developed in this research vindicates benefits of IEC 61850 standard over hard wired systems. Prolonged outage times due to test set preparation using hard wires are drastically reduced. The thesis findings and deliverables will be used as a solution to industrial problems, postgraduate studies of other students and research project.
APA, Harvard, Vancouver, ISO, and other styles
48

Grosse, Philippe. "Application of knowledge engineering techniques for managing operational expertise of transmission network operator." Thesis, University of Strathclyde, 2002. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.249049.

Full text
APA, Harvard, Vancouver, ISO, and other styles
49

Chen, Shelley L. "Programs for calculating high temperature ampacity and sag for overhead electrical conductors." Thesis, Georgia Institute of Technology, 1999. http://hdl.handle.net/1853/17933.

Full text
APA, Harvard, Vancouver, ISO, and other styles
50

Wei, Ping, and 魏萍. "A comprehensive approach to transmission pricing and its applications." Thesis, The University of Hong Kong (Pokfulam, Hong Kong), 2002. http://hub.hku.hk/bib/B31243733.

Full text
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!

To the bibliography