To see the other types of publications on this topic, follow the link: Electrical installation.

Journal articles on the topic 'Electrical installation'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 50 journal articles for your research on the topic 'Electrical installation.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse journal articles on a wide variety of disciplines and organise your bibliography correctly.

1

Amalia Dwilesmana and Bagus Dwi Cahyono. "ANALISIS SISTEM INSTALASI LISTRIK GEDUNG BERTINGKAT DI PT. MULTI GROUP HOLDING COMPANY." Jurnal Penelitian Rumpun Ilmu Teknik 2, no. 2 (2023): 124–38. http://dx.doi.org/10.55606/juprit.v2i2.1768.

Full text
Abstract:
The electrical installation system is a process of distributing electrical power generated from an electric power source to electrical devices or loads. The main purpose of lighting electrical installations is to provide comfort in situations that require accuracy, lighting that has a high intensity is needed, while for jobs that require accuracy, there is no need to use lights that have a large brightness. The installation is divided into two parts, namely electrical power installation and lighting installation. Indoor installations are electrical installations inside buildings (including for
APA, Harvard, Vancouver, ISO, and other styles
2

Putra, Adi Pratama. "Penyuluhan Dan Instalasi Kelistrikan Pada Mesin Pemisah Kulit Ari Kedelai UMKM Produksi Tempe Tradisional Di Desa Wringinpitu Banyuwangi." JATI EMAS (Jurnal Aplikasi Teknik dan Pengabdian Masyarakat) 3, no. 2 (2019): 155. http://dx.doi.org/10.36339/je.v3i2.243.

Full text
Abstract:
Problems found in related to electrical installations in buildings/houses are not arranged perfectly or the installation is not following to the procedure because there have been improvements to the electrical installations of the building or house beforehand. Electrical installations that will be installed should also consider the concept of savings and costs Installation and addition of electrical installations with equipment that is not based on knowledge of electrical installations can be dangerous if not carried out by save maintenance and security of existing electrical equipment. Based
APA, Harvard, Vancouver, ISO, and other styles
3

Hadiyanto, Gunawan Toto, Djoko Anwar Mardiono, Bambang Apriyanto, Nurhatisyah, and Nur Effendi Effendy. "INSTALASI LISTRIK MASJID AL-IKHLAS KAMPUNG KARET-BATU BESAR KECAMATAN NONGSA KOTA BATAM." Jurnal Pendekar Nusantara 1, no. 1 (2023): 53–63. http://dx.doi.org/10.37776/pend.v1i1.1221.

Full text
Abstract:
The people of Kampung Karet, Nongsa District, most of them still don't understand about electrical installations, the condition of the electrical installation system in people's homes and especially places of worship (mosques) are still many that do not comply with general regulations regarding electrical installations. Apart from that, there are still many connections. -connection of electrical installations carried out by the community itself which does not comply with regulations. Community service by providing counseling and going directly to see the location that is the target of carrying
APA, Harvard, Vancouver, ISO, and other styles
4

Nikolsky, Oleg, Vadim Faranosov, Dmitry Surinsky, and Evgeniy Uskov. "Multicriteria assessment of anthropogenic risk of electrical installations based on simulation modeling." АгроЭкоИнфо 1, no. 61 (2024): 5. http://dx.doi.org/10.51419/202141105.

Full text
Abstract:
Risk management in a human-machine system is considered. The basic models and methods of decision-making, “man - electrical installation - environment” are presented. The method of risk analysis is considered. An expert software complex is proposed that implements the risk assessment of electrical installations. Keywords: HUMAN-MACHINE SYSTEM, RISK MANAGEMENT, ELECTRICAL INSTALLATION, MULTICRITERIA ANALYSIS, RISK ANALYSIS METHOD, “BOW TIE”, FIRE RISK OF ELECTRICAL INSTALLATIONS, SIMULATION MODEL
APA, Harvard, Vancouver, ISO, and other styles
5

Merry Dhani Anitasari, M. Saleh Al Amin, Irine Kartika F, and Yudi Irwansi. "Evaluasi Instalasi Kelistrikan Pada Gedung Vessel Traffic Service Palembang." Mars : Jurnal Teknik Mesin, Industri, Elektro Dan Ilmu Komputer 2, no. 2 (2024): 13–26. http://dx.doi.org/10.61132/mars.v2i2.87.

Full text
Abstract:
Electrical installation is one of the important elements in buildings. Safe electrical installations that comply with applicable safety standards can prevent electrical accidents. This research aims to evaluate the electrical installation in the Palembang Vessel Traffic Service (VTS) Building. Evaluation is carried out by measuring and calculating several parameters, namely: voltage and current values, current carrying capacity (KHA), circuit breaker (CB) size, short circuit impedance, grounding value. Quantitative research methods were used because this research aims to evaluate the electrica
APA, Harvard, Vancouver, ISO, and other styles
6

Kartika Sekarsari, Heri Kusnadi, Sunardi, and Oky Supriadi. "Pemberdayaan Masyarakat di Wilayah Benda Baru Melalui Pelatihan Instalasi Listrik Rumah Tangga." Dinamisia : Jurnal Pengabdian Kepada Masyarakat 4, no. 3 (2020): 426–33. http://dx.doi.org/10.31849/dinamisia.v4i3.4016.

Full text
Abstract:
The Community empowerment through an activity related to the provision of specific skills can support its independence. Technical training of simple home electrical installation is one form of Community Service (PKM) which contributes to supporting independence in the community, especially residents who live on Jln. H. Nurleman Benda Baru Pamulang, South Tangerang City. Training in the form of community independence for simple home electrical installations is taught through learning material related to electricity, K3, and the implementation of electrical installation practice using training m
APA, Harvard, Vancouver, ISO, and other styles
7

Anwar, Syarifil. "SISTEM PROTEKSI TEGANGAN SENTUH PADA INSTALASI LISTRIK BERBASIS EARTH LEAGAGE CIRCUIT BREAKER (ELCB)." AL ULUM JURNAL SAINS DAN TEKNOLOGI 6, no. 2 (2021): 112. http://dx.doi.org/10.31602/ajst.v6i2.5230.

Full text
Abstract:
An electrical installation is a series of electrical installation equipment that connects an conductor with the electrical equipment used (consumers). The protection factor (safety) is a consideration that must be considered in designing an electrical installation so that it can be used optimally, effectively, efficiently, safely, properly and correctly while ensuring fire safety, of course in accordance with the General Requirements for Electrical Installation (PUIL) 2011. Touch voltage, which means that if a live wire is touched or held on a cable that is stripped of its insulation, then we
APA, Harvard, Vancouver, ISO, and other styles
8

Triwijaya, Santi, Andri Pradipta, Fathurrozi Winjaya, Akhwan Akhwan, and Trisna Wati. "PENINGKATAN KOMPETENSI MELALUI PELATIHAN INSTALASI LISTRIK DALAM DIKLAT PEMBERDAYAAN MASYARAKAT." JMM (Jurnal Masyarakat Mandiri) 7, no. 1 (2023): 876. http://dx.doi.org/10.31764/jmm.v7i1.12808.

Full text
Abstract:
Abstrak: Teknisi yang tidak memiliki kualifikasi di bidang instalasi listrik dapat menghasilkan instalasi yang tidak aman. Untuk mengatasi kondisi tersebut diperlukan peningkatan keterampilan dari teknisi instalasi listrik melalui pendidikan non formal berbasis pada pengabdian kepada masyarakat (PKM) yaitu Diklat Pemberdayaan Masyarakat (DPM) Instalasi listrik. Tujuan dari pelaksanaan PKM adalah menghasilkan sumber daya manusia yang memiliki kualifikasi dalam bidang instalasi listrik. Peserta DPM Instalasi Listrik pada bulan juni 2022 ada sejumlah 20 peserta dari SMK Negeri 1 Madiun yang berla
APA, Harvard, Vancouver, ISO, and other styles
9

Sufrianto, Wendra, and Oriza Candra. "The Effect Of Electrical Installation Trainer Media On Undergraduate Students Learning Outcomes Of Domestic Electrical Installation Practice Course." JTEV (Jurnal Teknik Elektro dan Vokasional) 8, no. 1 (2022): 128. http://dx.doi.org/10.24036/jtev.v8i1.116682.

Full text
Abstract:
This study aims to analyze the effect of using an electrical installation trainer media on the learning outcomes of students practicing domestic electrical installations in the electrical engineering department of the State University Of Padang. This type of research is quantitative research. The research method used is an experimental research method with a True experimental design with a Posttest-Only Control Group Design type of research design. Collecting data using a research instrument that was given a post test in the form of multiple choice questions using random sampling, by dividing
APA, Harvard, Vancouver, ISO, and other styles
10

Patel, Prakashkumar Hasmukhbhai, Jigar Rajesh Juthani, Baxis Patel, and Dilip Rasiklal Vahoniya. "Quantification and Analysis of Human Errors Across the Life Cycle of Electrical Installations." Archives of Current Research International 25, no. 1 (2025): 113–23. https://doi.org/10.9734/acri/2025/v25i11043.

Full text
Abstract:
The modern power system has different installations and as they are manmade, their consistency and security are dependent on human intervention. This research study has been carried out to analyse different types of faults in Electrical Installations according to life cycle and human related intervention in the various stages of the life cycle of an electrical installation. Secondary data has been collected to derive the results regarding the electrical faults in Electrical Installations according to life cycle and human intervention in the various stages of the life cycle of an electrical ins
APA, Harvard, Vancouver, ISO, and other styles
11

Tukhvatullin, Midhat, Yuri Arkhangelsky, Rustam Aipov, and Eduard Khasanov. "Materials and Economic Aspects of Designing Microwave Electrical Installations." Mathematical Modelling of Engineering Problems 9, no. 2 (2022): 336–42. http://dx.doi.org/10.18280/mmep.090206.

Full text
Abstract:
Ultrahigh-frequency electro-technical installations are capable of performing thermal microwave modification of dielectric and non-thermal microwave modification of polymer materials and products, as a result of which new properties and parameters appear in the object processed in the working chamber of such an installation. When designing microwave electrical installations, it is necessary to consider the relationship between the dielectric parameters of the processed object and the parameters of the microwave electromagnetic field of the working chamber of the installation. The paper conside
APA, Harvard, Vancouver, ISO, and other styles
12

Purwono, Efa Yumna. "Evaluasi Kelayakan Instalasi Gedung TTSK 3 Lantai PT Phapros, Tbk Semarang." ENERGI & KELISTRIKAN 14, no. 1 (2022): 109–18. http://dx.doi.org/10.33322/energi.v14i1.1675.

Full text
Abstract:
The development of time and the increasing need for electricity, electrical installations must undergo changes both in quality and quantity. The decrease in the quality of electrical installations and changes in the quantity of load points can result in changes in the quality and quantity of installation feasibility and safety of the wearer. Therefore, checking and evaluating electrical installations is carried out. Research at the TTSK building of PT Phapros, Tbk determines predetermined criteria, including: earth resistance, insulation resistance, safety, and delivery cross-section. After me
APA, Harvard, Vancouver, ISO, and other styles
13

Lesmana, Dicky. "IMPROVED FIRE-PROOF INSTALLATION SECURITY TECHNOLOGY." International Journal of Economic, Technology and Social Sciences (Injects) 2, no. 1 (2021): 102–8. http://dx.doi.org/10.53695/injects.v2i1.257.

Full text
Abstract:
In this study conducted a discussion of electrical installation of buildings as electrical equipment assemblies in buildings related to each other, to meet certain purposes or intentions and have coordinated characteristics, what is already stated in the General Requirements of Electrical Installation (PUIL 2000). The purpose and purpose of the electrical installation is for the business of electrical installations to be held properly, to ensure human safety from the dangers of electric shock, the safety of electrical installations and their equipment, the security of buildings and their conte
APA, Harvard, Vancouver, ISO, and other styles
14

Eremina, Tamara, and Olga Plishkina. "Methods for assessing multi-component damage in emergency modes of electrical installations at agricultural facilities." АгроЭкоИнфо 1, no. 67 (2025): 11. https://doi.org/10.51419/202151111.

Full text
Abstract:
The article characterizes threats of emergency, in which human, electrical installation and environment interact with each other, and its sequences (accidents, fires, electrical traumas) interacting with electro-magnetic field, that is harmful for human health and environment. The risk of man-caused emergency situation with consideration of all kind of incidents and expenses, as well as waste, depending on a number of factors is estimated. It is pointed that risk integral indicating potential dangers takes into account social-economical, technological and ecological wastes, involving physical
APA, Harvard, Vancouver, ISO, and other styles
15

Soldatov, А. I., A. A. Soldatov, M. A. Kostina, A. A. Abouellail, and S. I. Bortalevich. "DETECTION ALGORITHM FOR FAULTY CONTACT JOINTS IN ELECTRICAL NETWORK." Eurasian Physical Technical Journal 22, no. 1 (51) (2025): 76–82. https://doi.org/10.31489/2025n1/76-82.

Full text
Abstract:
The article proposes a thermoelectric method for monitoring the contact resistance of contact joints in power grids. It describes an algorithm to detect faulty contact joints with resistance exceeding the value specified in regulatory standards. The algorithm is considered using the example of a circuit containing five contact joints and three electrical installations. The algorithm is based on calculating contact resistance from the measured values of thermoelectromotive force and flowing current only at the moment the electrical installation is turned on, which makes it possible to calculate
APA, Harvard, Vancouver, ISO, and other styles
16

Kurniasih, Novi. "Pelatihan Instalasi Penerangan Untuk Mahasiswa Teknik Elektro." TERANG 2, no. 2 (2020): 126–36. http://dx.doi.org/10.33322/terang.v2i2.429.

Full text
Abstract:
The training of lighting installations for electrical engineering students is intended to provide an understanding of the electricity dangers and skills in terms of installing lighting installations that comply with PUIL standards. With the training of this lighting installation, it can help electrical engineering students to install and repair electrical installations independently even with having these skills can make those students open business opportunities so that employment opportunities will be open and at least they will have income for themselves. This training is given in two stage
APA, Harvard, Vancouver, ISO, and other styles
17

Kusumah, Ilman Himawan, Muhamad Shobirin, Eka Muhammad Haryadi, Adi Mulyadi, and Ranti Nurdiansari. "Counseling on the Importance of Electrical Installation Safety in Tegalpanjang Village." REKA ELKOMIKA: Jurnal Pengabdian kepada Masyarakat 2, no. 2 (2021): 49–57. http://dx.doi.org/10.26760/rekaelkomika.v2i2.49-57.

Full text
Abstract:
Electricity has a very vital role in everyday life, therefore the electricity network must be properly maintained and protected, otherwise, not only disrupt the need for electricity but it can also endanger human safety. One type of electrical hazard that often arises is fire that caused by the electrical equipment used was not under the PUIL Standard (General Requirements for Electrical Installation in Indonesia) and COE (Certificate of Operation Eligibility). Beside carelessly installation that not comply with regulations that often cause electrical short circuit.. The purpose of this commun
APA, Harvard, Vancouver, ISO, and other styles
18

Supriyono, Heru, Nurhadi Dharmaputra Permata Adi, and Anas Awali Yudha. "Training to Improve the Knowledge and Skills of Junior High School Students in the Field of Electrical Installation." Journal of Community Services and Engagement: Voice of Community (VOC) 3, no. 2 (2023): 7–16. http://dx.doi.org/10.23917/voc.v3i2.2536.

Full text
Abstract:
The partner of this social service activity is the Muhammadiyah 11 JuniorHigh School Special Program as part of the residents in the preaching area ofthe Muhammadiyah Branch Management (PCM) of Nogosari, BoyolaliRegency. Regarding electrical installation, the problem faced by partners isthat many students are still unfamiliar with electrical installation especiallyon technical specifications. The objective of this social service is to increasethe knowledge and skills of students in electrical installation. The method ofimplementing the service is in the form of socialization and training in 3m
APA, Harvard, Vancouver, ISO, and other styles
19

Rusliadi, Rusliadi. "Perbaikan Instalasi dan Pemasangan Lampu Penerangan Masjid Kampung Kiat, Distrik Fakfak Barat." Society : Jurnal Pengabdian Masyarakat 1, no. 4 (2022): 229–33. http://dx.doi.org/10.55824/jpm.v1i4.118.

Full text
Abstract:
Electrical installation is one way to distribute electricity from the generating center to the load center. The occurrence of fires due to electricity can be caused by several things, including installations that are not in accordance with PUIL standards, irregular maintenance and the use of sockets that accumulate. This is what encourages lecturers and students of the electrical engineering study program at the Fakfak State Polytechnic to carry out a service to repair the installation and installation of mosque lighting in the village of Tips, West Fakfak district. Based on the results of thi
APA, Harvard, Vancouver, ISO, and other styles
20

Wahyu Pramon, Eko, Karnoto Karnoto, and Titik Nurhayati. "EVALUASI INSTALASI LISTRIK PADA GEDUNG MULTI CENTRE OF EXCELLENT (MCE) RUMAH SAKIT ISLAM SULTAN AGUNG SEMARANG." eLEKTRIKA 9, no. 1 (2018): 17. http://dx.doi.org/10.26623/elektrika.v9i1.1110.

Full text
Abstract:
<p> MCE Building Sultan Agung Islamic Hospital Semarang is a public facility that requires an electrical installation system that is in accordance with PUIL 2000. The purpose of evaluating electrical installations at the Multi Center of Excellent (MCE) building in Sultan Agung Semarang Islamic Hospital is to find out electrical installations in accordance with PUIL 2000 Evaluation of electrical installations includes calculation of MCB security and calculation of cable size. Calculation using manual calculation method and calculation using Ecodial Calculation 4.7 software. The calculatio
APA, Harvard, Vancouver, ISO, and other styles
21

Anggi, Jumiati Ilham, and Amirudin Yunus Dako. "Evaluasi Sistem Instalasi Tenaga Listrik berdasarkan Standar PUIL 2011 (Studi Kasus Pada PT. Multi Nabati Sulawesi Luwuk)." Research Review: Jurnal Ilmiah Multidisiplin 4, no. 1 (2025): 277–88. https://doi.org/10.54923/researchreview.v4i1.141.

Full text
Abstract:
Electrical power installation systems in the industrial sector require proper planning in accordance with the General Electrical Installation Requirements (PUIL 2011). Common issues in industrial electrical installation systems include voltage drop on the load side, unbalanced loads, and low power factor during power distribution and utilization. Therefore, this study aims to evaluate the electrical power installation system at PT. Multi Nabati Sulawesi-Luwuk to ensure it operates effectively and efficiently while addressing potential disturbances. The research employs an evaluation method con
APA, Harvard, Vancouver, ISO, and other styles
22

Pujiyanto, Fajar, and Susanto Susanto. "ANALISIS ELECTRIC GROUNDING SYSTEM UNTUK KEANDALAN DAN KESELAMATAN DALAM INSTALASI KELISTRIKAN." Majalah Ilmiah Gema Maritim 24, no. 2 (2022): 95–104. http://dx.doi.org/10.37612/gema-maritim.v24i2.296.

Full text
Abstract:
Electrical installations need to be installed correctly by referring to the basic guidelines, namely the General Guidelines for Electrical Installation (PUIL) for the country of Indonesia, or referring to other guidelines with international standards, namely the International Electrotechnical Commission (IEC) and IEEE. Electrical installations must have a protection system, high reliability when operating, and the ability to respond to installation disturbances quickly. The protection system provides safety for living things, property, and the electrical installation itself. The grounding syst
APA, Harvard, Vancouver, ISO, and other styles
23

Khairudin, Moh, M. Iskandar, Istanto Wahyu Djatmiko, and Irdayanti Mat Nashir. "Virtual Trainer for Mobile Augmented Reality Based Electrical Lighting Installation." International Journal of Interactive Mobile Technologies (iJIM) 14, no. 07 (2020): 104. http://dx.doi.org/10.3991/ijim.v14i07.12397.

Full text
Abstract:
<p>Virtual Trainer of Mobile Augmented Reality (AR) -based Electrical Lighting Installation is a technology that can be utilized as a substitute for conventional trainers to modern virtual-based trainers. The use of virtual trainers Electric lighting installation can be used anywhere and anytime with the help of an Android-based smartphone device. The use of AR technology is a technological development that helps users be able to interact directly with lighting installation components in a virtual form that has been designed to resemble the actual form. This study applied AR technology t
APA, Harvard, Vancouver, ISO, and other styles
24

Ruwah Joto, Harrij Mukti K., Tresna Umar Syamsuri, Wijaya Kusuma, and Rahma Nur Amalia. "Analisis Keamanan Instalasi Listrik Penerangan dan Pompa Air di Wilayah Perkampungan." Elposys: Jurnal Sistem Kelistrikan 7, no. 3 (2023): 63–68. http://dx.doi.org/10.33795/elposys.v7i3.670.

Full text
Abstract:
The use of lighting installations installed in the RW VIII Kelurahan Kesatrian has various aspects interms of installation and use. To prevent losses due to the installation, the solution is to conduct electrical installationtraining. As a result of this training, it is hoped that the community can make efforts to install lighting or independentlyin their respective homes safely and correctly. The purpose of this Community Service is to provide knowledge andskills in installing electrical installations correctly and safely, given the use of household electrical appliances withvarious brands, e
APA, Harvard, Vancouver, ISO, and other styles
25

Askarov, R. R., K. V. Nikolaev, D. V. Ryzhkov, V. A. Manakhov, and S. R. Miranov. "Development of a standard design for a test installation of dielectric personal protective equipment based on a high voltage source AII-70." Power engineering: research, equipment, technology 26, no. 4 (2024): 17–28. http://dx.doi.org/10.30724/1998-9903-2024-26-4-17-28.

Full text
Abstract:
TARGET. The purpose of this work is to develop a standard design of an installation for testing personal protective equipment. According to the standard design, the installation should be more functional and cheaper than existing analogues, while its design should fully comply with the requirements of regulatory and technical documentation (Rules for the installation of electrical installations, Rules of labor protection when working in electrical installations).METHODS. According to the developed standard design, it implies the use of АИИ-70 test devices, which have been put into storage as a
APA, Harvard, Vancouver, ISO, and other styles
26

Rauf, Abdul, Belly Yan Dewantara, and Istiyo Winarno. "Design of Protection Relay Prototype Against Arduino Uno Overload Interference in Electrical Installations." Fidelity : Jurnal Teknik Elektro 5, no. 3 (2023): 168–74. http://dx.doi.org/10.52005/fidelity.v5i3.168.

Full text
Abstract:
Electrical installations are prone to disturbances, both short circuits and overloads, for this reason protection is needed in home electrical installations. MCB or mini circuit breaker is generally widely used as protection in electrical installations how the MCB works. When there is an overload disturbance, the MCB will cut off the electric current flowing in the electrical installation. In this study, researchers will create a prototype that will detect overload disturbances that occur in electrical installations. The advantage of developing this prototype is that the flow can be monitored.
APA, Harvard, Vancouver, ISO, and other styles
27

Burhan, Muh Iswal, Akhyar Muchtar, Elfira Makmur, Hilda Ashari, and Dessy Ana Laila Sari. "Sosialisasi Listrik Aman di Kelurahan Sibatua Kecamatan Pangkajene Kabupaten Pangkep." TEKIBA : Jurnal Teknologi dan Pengabdian Masyarakat 2, no. 2 (2022): 37–40. http://dx.doi.org/10.36526/tekiba.v2i2.2240.

Full text
Abstract:
Abstract – The problem is based on the frequent occurrence of fires due to short circuits electricity, this is the result of a lack of public understanding regarding the use, selection of correct and safe electrical equipment and the high number of houses that have the potential to catch fire due to old electrical installations more than 20 years, human error, and a house made of wood. Installation Equipment electricity is a solution offered to the community by referring to on General Electrical Installation Requirements (PUIL 2011) for residential houses and the Indonesian National Standard (
APA, Harvard, Vancouver, ISO, and other styles
28

Dina, Hardianti. "Kompetensi Siswa Terhadap Pembelajaran Instalasi Listrik Kelas XI TITL SMK Cendekia Batujajar." Madani: Jurnal Ilmiah Multidisiplin 1, no. 4 (2023): 314–20. https://doi.org/10.5281/zenodo.7963419.

Full text
Abstract:
This paper discusses the research conducted related to learning about electrical installation at Cendekia Batujajar Vocational School. This study aims to increase competency and determine students' knowledge and understanding of learning about electrical installation at Cendekia Batujajar Vocational School, where this learning has a percentage of 56,6% where students are less interested in the selection. The research was conducted through a direct, active and interactive learning approach. This development procedure is carried out by applying a project-based learning development model. Ele
APA, Harvard, Vancouver, ISO, and other styles
29

Prasetyo, Widyanto Hadi, Dhio Dwinofiansyah Putra, Albastomiroji, and Pradita Teguh Irawan. "Analysis of Social Return on Investment (SROI) and Community Satisfaction Index (IKM) in Electrical Installation Training and Certification CSR Program PT PLN (Persero) UIP Kalbagba." Proceeding of International Conference on Digital, Social, and Science 1, no. 01 (2024): 251–62. https://doi.org/10.62201/icodss.v1i01.169.

Full text
Abstract:
Corporate Social Responsibility Program Electrical Installation Training and Certification, Kuala Kurun Village, Kurun District, Gunung Mas Regency by PT PLN (Persero) West Kalimantan Development Main Unit (UIP Kalbagbar) is a form of company contribution and commitment to supporting the Sustainable Development Goals (SDGs) program launched government, especially the pillars of economic and social development. There were 16 participants in the Corporate Social Responsibility Training and Electrical Installation Certification Program and 13 respondents. The Corporate Social Responsibility Progr
APA, Harvard, Vancouver, ISO, and other styles
30

Dobrzycki, Arkadiusz, Leszek Kasprzyk, Muhammed Sefa Çetin, and Muhsin Tunay Gençoğlu. "Analysis of the Influence of the Charging Process of an Electrical Vehicle on Voltage Distortions in the Electrical Installation." Applied Sciences 14, no. 17 (2024): 7691. http://dx.doi.org/10.3390/app14177691.

Full text
Abstract:
The noticeable dynamic development of electromobility poses new challenges for the energy industry and users of electric vehicles. One of these challenges is coping with the change in the way we refuel. In the case of electric vehicles, the batteries can also be charged via home electrical installations. The presence of a new, non-linear load with significant power may affect the quality parameters of electricity in this installation and therefore indirectly affect the operation of other loads. In order to investigate the possible impact of the electric vehicle charging process on these parame
APA, Harvard, Vancouver, ISO, and other styles
31

Golisz, Ewa, Krzysztof Korpysz, Olga Rutkowska, Szymon Głowacki, and Andrzej Bryś. "Efficiency analysis of photovoltaic systems." E3S Web of Conferences 154 (2020): 05003. http://dx.doi.org/10.1051/e3sconf/202015405003.

Full text
Abstract:
The goal of the study was to analyse the efficiency of two existing photovoltaic micro-installations with the power of approx. 40 kWp. The main factor differing the two installations being analysed was the arrangement of modules in relation to the sides of the world, one is south-west and the other is east-west. The total yield of electrical energy in 2017 from the south-west installation was higher and amounted to 34980 kWh. For the east-west installation the amount of energy generated was equal to 31180 kWh. 4 methods of forecasting electrical energy yield were discussed. Simple computationa
APA, Harvard, Vancouver, ISO, and other styles
32

Suprihartini, Yayuk, Taryana Taryana, Rubby Soebiantoro, Djoko Herwanto, and Rini Sadiatmi. "Instalasi Ulang Penerangan Listrik di Pondok Pesantren Tarbiyatunnisa Desa Serdang Kulon Kecamatan Panongan Kabupaten Tangerang." Jurnal Abdimas ADPI Sains dan Teknologi 4, no. 1 (2023): 33–42. http://dx.doi.org/10.47841/saintek.v4i1.282.

Full text
Abstract:
In today's human life, presumably almost depend on electricity. Some of the things that arise if there is a disturbance in electricity, among others, there is no lighting resulting in darkness at night. Electrical installation installation standards have been regulated in the General Electrical Installation Requirements. Apart from matters relating to the security of the electrical installation network, there are other things that we must pay attention to. This is the standard intensity of illumination. The intensity of room lighting is determined in lux units. The amount of room lighting inte
APA, Harvard, Vancouver, ISO, and other styles
33

Bunga Lestari, Lea, Purwanto Gendroyono, and Ermi Media's. "STUDI SURVEY KELAIKAN INSTALASI LISTRIK TEGANGAN RENDAH PADA RUMAH TINGGAL SEDERHANA DENGAN DAYA 900 VA-2200 VA (Studi dilakukan pada RW 02 Kelurahan Kayu Manis Kecamatan Matraman Jakarta Timur)." Journal of Electrical Vocational Education and Technology 1, no. 2 (2020): 32–36. http://dx.doi.org/10.21009/jevet.0012.06.

Full text
Abstract:
ABSTRACT 
 Research of this thesis examines the feasibility of electrical installations on residential houses in RW 02, Kelurahan Kayu Manis Kecamatan Matraman with a power of 900 VA-2200 VA and the age of the electrical installation of more than 15 years. Refers to the standard installation of Airworthiness Requirements General Installation listri (PUIL) for housing. Collecting data by observation, documentation and measurement. Observations made on safety equipment and electrical installations to determine the quality of the electrical installation. Measurement of insulation resistance,
APA, Harvard, Vancouver, ISO, and other styles
34

Львов, М. Ю., А. В. Лесив, Е. Е. Серебрянников та А. А. Назаров. "СОВЕРШЕНСТВОВАНИЕ МЕТОДОВ НЕРАЗРУШАЮЩЕГО ТЕПЛОВОГО КОНТРОЛЯ ДЛЯ ПРЕДУПРЕЖДЕНИЯ ПОЖАРОВ ПО ЭЛЕКТРОТЕХНИЧЕСКИМ ПРИЧИНАМ В ЗДАНИЯХ ЖИЛОГО И ОБЩЕСТВЕННОГО НАЗНАЧЕНИЯ". Pozharnaia bezopasnost`, № 2(119) (9 червня 2025): 44–56. https://doi.org/10.37657/vniipo.pb.2025.97.56.004.

Full text
Abstract:
В статье рассматриваются методы теплового контроля при эксплуатации электроустановок зданий жилого и общественного назначения. Проведен анализ существующих методик термоиндикаторного и тепловизионного контроля элементов электроустановок, а также критериев, применяемых для выявления аварийных и пожароопасных дефектов. The article analyzes modern methods for assessing the fire safety of electrical installation elements in residential and public buildings. Two types of defects in electrical installation elements are considered. The first one is an emergency defect which is characterized by reachi
APA, Harvard, Vancouver, ISO, and other styles
35

Fangrat, Jadwiga, Katarzyna Kaczorek-Chrobak, and Bartłomiej K. Papis. "Fire Behavior of Electrical Installations in Buildings." Energies 13, no. 23 (2020): 6433. http://dx.doi.org/10.3390/en13236433.

Full text
Abstract:
Electrical installations are a significant component of fire load inside a building, although they are often neglected in the overall fire safety analysis and are not subjected to any kind of fire safety evaluation of a building. A typical electrical installation unconnected to the mains was experimentally studied using a single burning item (SBI) test apparatus, fixed to two types of popular non-combustible or combustible (wooden-based) backgrounds simulating a typical building internal wall or ceiling. The semi-real scale test showed that poly(vinyl chloride) (PVC) cable, commonly used in in
APA, Harvard, Vancouver, ISO, and other styles
36

Sukamdi, Anang Dasa Novfowan, Mochammad Mieftah, Rachmat Sutjipto, and Dhimas Dhesah Kharisma. "Instalasi Listrik Penerangan Untuk Masyarakat Binaan Disnaker Di Pemkot Malang." Elposys: Jurnal Sistem Kelistrikan 7, no. 3 (2023): 45–50. http://dx.doi.org/10.33795/elposys.v7i3.667.

Full text
Abstract:
This study discusses the installation of lighting electrical installations that are appropriate and safe for the communityassisted by the Manpower Office in Malang City Government. The existence of this research is expected to provide additional skills ininstalling lighting installations, to be used in working to install lighting installations that are correct and safe and in accordance withstandards, so as to minimize work hazards or accidents due to errors due to installation and use. This research activity was carried out inthe AK Building of Malang State Polytechnic, Jalan Soekarno Hatta M
APA, Harvard, Vancouver, ISO, and other styles
37

Lipkovich, Igor, Maxim Ukraintsev, Irina Egorova, Nadezhda Petrenko, and Valentin Golovinov. "Safety basics when installing electrical wiring in hazardous area." АгроЭкоИнфо 3, no. 51 (2022): 26. http://dx.doi.org/10.51419/202123326.

Full text
Abstract:
The article discusses the frequent causes of fires in electrical installations. The probability of the explosion or fire depends on many factors, one of the main ones is the circulation in the production or storage of explosives or substances that can explode or ignite when combined with air or other substances under the action of the open flame, high temperatures. The hazardous area category reflects how easily an explosive atmosphere can be ignited by sparks or arcs. Personnel carrying out maintenance and inspection of electrical installations in hazardous areas must have documentation that
APA, Harvard, Vancouver, ISO, and other styles
38

Dwi Cahyono, Bagus, and Dahliya Sulastri. "Development Of Electrical Installation Learning Me-dia With Delphi Language." International Journal of Engineering, Science and Information Technology 1, no. 3 (2021): 23–27. http://dx.doi.org/10.52088/ijesty.v1i3.81.

Full text
Abstract:
Learning Media is a learning tool that is used by someone by using tools that are made to facilitate the delivery of material when teaching at school. Things like that really help teachers in teaching in schools and are a solution to make students happy when learning and not feel bored. One of the learning materials in Vocational High Schools is electrical installation material. Introducing electrical installation material will be very difficult if only with books. Therefore this study aims to adopt material about electrical installations in a computer system. This system is called the Electri
APA, Harvard, Vancouver, ISO, and other styles
39

Gabova, M. A., O. K. Nikolsky, and M. V. Guner. "The expert system for assessing fire risks of electrical installations in the agrarian industrial complex based on neural networks." Journal of Physics: Conference Series 2142, no. 1 (2021): 012005. http://dx.doi.org/10.1088/1742-6596/2142/1/012005.

Full text
Abstract:
Abstract The article is devoted to the analysis of fire risks of the operation of electrical installations in the agro-industrial complex of the region. According to statistics, the number of fires occurring for electrical reasons is steadily increasing, which makes the issue of fire risk management relevant. In order to identify and prevent these risks, a technogenic safety system has been developed, presented as a set of methods and tools, which are based on the generation of new data on the causes of threats to the operation of electrical installations based on the analysis of data on the c
APA, Harvard, Vancouver, ISO, and other styles
40

Wahyuningsih, Erfiana, Belinda Ayuningtyas, Islamiah Kamil, Ganjar Febriyani Pratiwi, and Tri Nur Arifin. "Enhancement of the Safety and Efficiency of Electrical Installations at UKM Kemuning Mandiri to Foster Sustainable Production." ABDIMAS: Jurnal Pengabdian Masyarakat 8, no. 1 (2025): 706–15. https://doi.org/10.35568/abdimas.v8i1.6167.

Full text
Abstract:
At UKM Kemuning Mandiri in Cogreg Village, we improved understanding and safety in the operation of electrical devices by introducing a regular maintenance program, providing training, and performing repairs to electrical installations. We identified a lack of knowledge regarding safe electrical installations as the primary cause of work accidents and equipment damage. We utilized training materials to convey the importance of routine maintenance, the safe use of electrical outlets, and standard installation procedures. We assess the existing electrical installation and provide recommendations
APA, Harvard, Vancouver, ISO, and other styles
41

Candra, Oriza, Syaiful Islami, Nevi Faradina, Syamsuarnis Syamsuarnis, Elfizon Elfizon, and Hendri Hendri. "Pelatihan Smart Home dengan Smart Control untuk Instalasi Listrik Berbasis Wifi." JTEIN: Jurnal Teknik Elektro Indonesia 3, no. 2 (2022): 357–63. https://doi.org/10.24036/jtein.v3i2.249.

Full text
Abstract:
Skills training on smart home electric lighting installations to provide skills for students and teachers of the State 1 Buo Vocational High School (SMK) in installing and repairing smart home electrical installations independently in addition to knowledge and skills about wifi networks. This service is carried out at SMKN 1 Lintau Buo because there is no supporting equipment and do not have knowledge about electrical installations in smart home systems. With this activity, it is expected that students and teachers have knowledge of electric lighting installations. This training is given in tw
APA, Harvard, Vancouver, ISO, and other styles
42

Anyigor, Ikeokwu Stanley, Nkechi Jessica Anyigor, Thomas Sunday Igwe, Ogochukwu Collins Nwuzor, and Ifeanyi Abraham Mgbebu. "Investigation of Technical Challenges in Quality Practices in the Installation of Electrical Conduit Wiring on Building Sites in Nigeria." Nigerian Journal of Physics 33, no. 3 (2024): 117–20. https://doi.org/10.62292/njp.v33i3.2024.300.

Full text
Abstract:
The technical challenges in quality practices in installing electrical conduit wiring on building sites in Nigeria have been investigated. This investigation aims to assess challenges in quality management practices in electrical conduit installation on building construction sites in Nigeria. To achieve this aim, both Survey and Descriptive research designs were applied. These were necessary to elicit relevant information from the study area. A total of 185 registered electrical professionals in the building industry from four geo-political zones of Nigeria and the Federal Capital Territory we
APA, Harvard, Vancouver, ISO, and other styles
43

Ashari, Hilda, and Dessy Ana Sari. "Analisis Sistem Instalasi Listrik Pada Menara Transmisi Telekomunikasi di Kota Makassar." JOURNAL ZETROEM 6, no. 2 (2024): 57–61. https://doi.org/10.36526/ztr.v6i2.3716.

Full text
Abstract:
This research is a quantitative study using survey methods aimed at determining the viability of electrical installations on telecommunications transmission towers. The research was conducted at UPD007 Telkomas, Makassar City, South Sulawesi Province. The variables in this study are the security of electrical installations, transmitters of electric installations and grounding of electricity installations. Data collection techniques are observation, documentation, interview and measurement techniques. Data analysis techniques used are descriptive data analysis using Persyaratan Umum Instalasi L
APA, Harvard, Vancouver, ISO, and other styles
44

OYEBOLA, Blessed Olalekan. "PASSWORD BASED ELECTRIC LOAD SWITCHING GEAR FOR THE SAFETY OF LINEMAN." International Journal of Engineering Science Technologies 1, no. 1 (2019): 48–55. http://dx.doi.org/10.29121/ijoest.v1.i1.2017.05.

Full text
Abstract:
Safety of human life is of a paramount importance. In high current switching system, switch gear protects electrical circuit. However there is need to provide confidence to working engineers during installation work on high voltage installations. To prevent accidental switching on of switch gear by unauthorized workforce, this paper proposed a more life secured switching password-enabled device that strengthen working confidence and inactivate unauthorized person from hazardous switching of electrical power installation without the notice of field working engineers.
APA, Harvard, Vancouver, ISO, and other styles
45

Blessed, Olalekan OYEBOLA. "PASSWORD BASED ELECTRIC LOAD SWITCHING GEAR FOR THE SAFETY OF LINEMAN." International Journal of Engineering Science Technologies 1, no. 1 (2017): 48–55. https://doi.org/10.5281/zenodo.283787.

Full text
Abstract:
Safety of human life is of a paramount importance. In high current switching system, switch gear protects electrical circuit. However there is need to provide confidence to working engineers during installation work on high voltage installations. To prevent accidental switching on of switch gear by unauthorized workforce, this paper proposed a more life secured switching password-enabled device that strengthen working confidence and inactivate unauthorized person from hazardous switching of electrical power installation without the notice of field working engineers.
APA, Harvard, Vancouver, ISO, and other styles
46

Muljono, Agung Budi, Nrartha I Made, Sultan Sultan, et al. "Pemberdayaan Masyarakat Desa Tumpak Kecamatan Pujut Lombok Tengah Melalui Pelatihan Uji Kelayakan Instalasi Listrik." Jurnal Gema Ngabdi 5, no. 1 (2023): 85–92. http://dx.doi.org/10.29303/jgn.v5i1.313.

Full text
Abstract:
The increasing demand for electrical energy, especially in the household sector, requires the use of electrical equipment with electrical installations that meet the safety standard criteria according to SNI: 0225 (PUIL 2011). Electrical energy provides great benefits for human life, but it is also a threat to human life. This can happen if you do not comply with the standards for installing and using electrical installation equipment in accordance with SNI: 0225 (PUIL 2011) and Minister of Energy and Mineral Resources No. 045 of 2005, as well as behavior that is not wise and proper in using e
APA, Harvard, Vancouver, ISO, and other styles
47

Basri, Muhammad Hasan, Muhammad Wildan Rifqi, Moh Basri, et al. "Penyuluhan Dan Pelatihan Instalasi Listrik Rumah Sederhana Pada Karang Taruna Muda Bestari Desa Sidodadi." Pengmasku 2, no. 2 (2022): 119–25. http://dx.doi.org/10.54957/pengmasku.v2i2.235.

Full text
Abstract:
Installation of electrical installations must be considered so that in its use it does not endanger yourself or others. Therefore, the installation of electrical installations must comply with existing standards. Based on a field survey in the houses of residents of Sidodadi village, Probolinggo Regency, there are still many peeling electrical cables, improper cable connections and use of cables that are not in accordance with PUIL 2000 standards, as well as excessive load buildup on power lines so that they are prone to electrical short circuits. Therefore, Community Service (PKM) activities
APA, Harvard, Vancouver, ISO, and other styles
48

Eremina, T. V., I. A. Shanygin, and M. B. Baldanov. "Technogenic Risk Optimization Method for Electrical Installations at a Production Facility." Occupational Safety in Industry, no. 7 (July 2021): 73–78. http://dx.doi.org/10.24000/0409-2961-2021-7-73-78.

Full text
Abstract:
The level of technogenic safety at the production facilities of the Russian Federation is expressed by low values. In this regard, the fire situation is a major hazard: a significant share is represented by the fires that occur at the electrical installations (up to 30 %). Fire risk analysis includes the determination of the probabilities of the occurrence of a fire and its consequences in order to obtain the risk numerical value that determines the fire safety of the object, and its comparison with an acceptable (tolerable) level. The use of a semantic description of risk-forming factors char
APA, Harvard, Vancouver, ISO, and other styles
49

Soluyanov, Yu I., A. I. Fedotov, A. R. Akhmetshin, E. A. Fedotov, and V. A. Khalturin. "Determination of estimated electrical loads of charging infrastructure for electric vehicles integrated into electrical installations of residential and public buildings." Power engineering: research, equipment, technology 26, no. 6 (2025): 94–107. https://doi.org/10.30724/1998-9903-2024-26-6-94-107.

Full text
Abstract:
RELEVANCE. The research aims to improve the regulatory framework governing the procedure for determining the estimated load of public buildings when integrating charging infrastructure for electric vehicles into the electrical installations of these buildings. THE PURPOSE. Determination of the schedule of electricity consumption, the coefficient of simultaneity and non-coincidence of maximums of the charging infrastructure for electric vehicles, with subsequent development of proposals for updating SP 256.1325800.2016 "Electrical installations of residential and public buildings. Design and in
APA, Harvard, Vancouver, ISO, and other styles
50

Walandouw, Frederico, Fransiskus Seke, and Jocke Rapar. "Analysis of Building Electrical Lighting System Tomohon City Regional Drink Water Company." JURNAL EDUNITRO Jurnal Pendidikan Teknik Elektro 4, no. 2 (2024): 111–20. http://dx.doi.org/10.53682/edunitro.v4i2.10321.

Full text
Abstract:
This study aims to see whether the electrical lighting installation at the Regional Drinking Water Company (Indonesian, abbreviated as PDAM) of Tomohon City follows the General Requirements for Electrical Installations (abbreviated as PUIL) or vice versa. Using the analysis approach, direct observation was performed at the research site, and after performing the study, it was discovered that many electrical lighting installation requirements did not satisfy PUIL. Following the measurements and calculations, it was found that none of the lighting in building A met PUIL standards, while for buil
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!