To see the other types of publications on this topic, follow the link: Estações de tratamento de água.

Dissertations / Theses on the topic 'Estações de tratamento de água'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 50 dissertations / theses for your research on the topic 'Estações de tratamento de água.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.

1

Scalize, Paulo Sergio. "Disposição de resíduos gerados em estações de tratamento de água em estações de tratamento de esgoto." Universidade de São Paulo, 2003. http://www.teses.usp.br/teses/disponiveis/18/18138/tde-17062016-152931/.

Full text
Abstract:
O presente trabalho foi realizado em duas fases. Na primeira, foram estimados os efeitos produzidos nos decantadores primários de uma ETE, após receber resíduo da ETA-SC, que utiliza sulfato de alumínio como coagulante. Foram realizados ensaios em colunas de sedimentação, onde os parâmetros SST, SSV, cor, turbidez, DQO, coliformes totais, Escherichia coli e parasitas, pesquisados no sobrenadante, diminuíram com o aumento da quantidade de resíduo adicionado. Com relação aos sedimentos obtidos nas colunas de sedimentação, foi encontrada maior quantidade de ST e menor resistência específica nos lodos provenientes das colunas que receberam os resíduos da ETA-SC. No teste de atividade metanogênica, a concentração molar de metano foi reduzida nos sistemas que receberam resíduo da ETA-SC, influenciando negativamente no desenvolvimento dos microrganismos metanogênicas. As espécies de microrganismos do gênero Methanothrix sp foram inibidas, sendo encontradas em maior número no frasco-reator controle e em menor quantidade a medida que se aumentou a quantidade do resíduo adicionado. Nesta etapa foi constatado que o resíduo da ETA-SC poderá apresentar interferências negativas sobre a digestão anaeróbia do lodo produzido em decantadores primários de uma ETE. Na segunda fase, na estação piloto, composta de lagoa de aeração seguida de lagoa de sedimentação, que recebeu resíduo da ETA-Fonte, que utiliza cloreto férrico como coagulante, foi verificado que tal resíduo melhorou a qualidade do efluente em termos de DQO, DBO, SST, turbidez, cor, amônio, nitrato, NTK e fosfato total. Os parâmetros ST, SDT, cloreto, nitrito, condutividade e pH não apresentaram diferenças significativas. Em relação ao exame microscópico não houve influências negativas no licor misto das lagoas de aeração. O lodo formado nas lagoas de sedimentação piloto apresentou-se em maior quantidade na lagoa que recebeu resíduo da ETA-Fonte. Neste lodo a resistência específica a filtração foi menor em comparação ao lodo da lagoa que não recebeu resíduo da ETA-Fonte. A desidratação deste lodo por centrifugação necessitou menor quantidade de polieletrólito. Baseado neste estudo não foi verificado interferências que possa impedir o lançamento do resíduo da ETA-Fonte na ETE-Araraquara.<br>This work was carried out in two phases. Effects of disposing the residues from a water treatment plant - ETASC, which uses alum as primary coagulant on the primary settling tanks was evaluated in the first one. Sedimentation tests using column indicated that parameters such as TSS, VSS, colour, turbidity, COD, total coliformes totais, Escherichia coli e parasites in the supernatant decreased with the increase of the amount of the water treatment wastes added to the column. With relation to the sediments produced in the column, it was found great amount of TS and lower specific solids resistance in those generated in the columns where the water treatment plant residues-WTPR were used. Molar concentration of methane was reduced in the tests performed with the sediments produced with water treatment plant residues and thus, altering negatively the development of methanogenic organisms. The growth of species of microorganism of genera Methanothrix sp was inhibited, which were found in great number in the control flask (with out WTPR) and in lower number as it was increased the amount of WTPR added to the column. It was observed that the WTPR generated in the city water treatment plant may interfere in the anaerobic digestion of sludge produced in primary settling tanks of a wastetreatment plant. A continuous pilot plant was operated in the second phase, which consisted of two aerated lagoon each one followed by a settling lagoon. Waste and WTPR from a watter treatment plant which ferric chloride were fed in one of the systems. It was observed that the use of WTPR improved the effluent quality of the settling lagoon evaluated in terms of COD, BOD, TSS, turbidity, color, ammonium, nitrate, TKN and total phosphate. Some parameters, such as TS, TDS, chloride, nitride, conductivity and pH did not present significant differences in both systems. Microscopic examinations indicated that no influence resulted in the aerated lagoon mixed liquor. A higher amount of sludge was formed in the lagoon system which received the WTPR. The specific resistance to filtration of this sludge was lower than that formed in the lagoon system with out WTPR addition. When dewatering both sludges, that one produced with the addition of WTPR required less amount of polymer. It was concluded that the WTPR produced in the water treatment plant of Araraquara may be disposed in the city wastewater treatment plant.
APA, Harvard, Vancouver, ISO, and other styles
2

Carvalho, Eraldo Henriques de. "Disposição de resíduos gerados nas estações de tratamento de água em estações de tratamento de esgoto com decantação primária." Universidade de São Paulo, 2000. http://www.teses.usp.br/teses/disponiveis/18/18138/tde-13072018-091220/.

Full text
Abstract:
No presente trabalho foram realizados estudos para verificar as interferências do lançamento de resíduos de Estações de Tratamento de Água nas Estações de Tratamento de Esgoto com decantação primária. A ETA estudada utilizava cloreto férrico como coagulante primário e possuía decantadores com descarga de fundo diária. As interferências nos decantadores primários da ETE foram simuladas por meio de testes de sedimentação e nos digestores de lodo, por meio de testes de tratabilidade anaeróbia. Testes e análises complementares também foram realizados para verificar eventuais interferências no tratamento biológico da fase líquida do esgoto e no tratamento físico da fase sólida do esgoto. Os resultados indicaram aumento na eficiência de sedimentação em conseqüência do aumento da quantidade e concentração do resíduo de ETA introduzido no esgoto. Obteve-se, por exemplo, um incremento de até 50% na remoção de sólidos suspensos e turbidez, 40% na de DQO e fosfatos e 30% na de nitrogênio. No entanto, obteve-se um maior volume de lodo primário, embora de menos concentrado. De acordo com os resultados dos testes de tratabilidade anaeróbia, os resíduos da ETA não foram tóxicos ao processo. Com relação ao tratamento biológico da fase líquida do esgoto e ao tratamento físico do lodo, não foram verificadas interferências significativas no desempenho dos mesmos, embora recomenda-se o desenvolvimento de pesquisas mais específicas, especialmente sobre o processo de adensamento. Pode-se concluir que resíduos similares aos gerados na ETA estudada poderão ser dispostos em ETEs com decantação primária, sem interferências prejudiciais no seu desempenho.<br>In the present work simulations studies were conducted to verify the impact of Water Treatment Plants (WTP) residuals on the performance of Wastewater Treatment Plants (WWTP). The WTP under investigation used ferric chloride as primary coagulant, was type Complete Cicle with sedimentation tanks with daily bottom discharge. The interferences in the primary sedimentation tanks were simulated using sedimentation tests, while the sludge digesters were simulated using anaerobic treatability tests. Complementary tests and analysis also were realized to verify eventual interferences in the wastewater biological treatment and in the physical treatment of the sludge. The results indicated an increment in the sedimentation eficiency caused by increasing the WTP residuals dose added into the wastewater. As WTP residuals was added at up to 225 mg dry weight solids per liter of wasterwater, the removal of solids, COD, phosphate and nitrogen, for example, increased in 50%. However, the primary tanks settled sludge volume increased considerably. According to the anaerobic treatability tests results, the WWP residuals had not toxical effects on the process, interfering positively on the methane production. Concerning the wastewater biological treatment and sludge physical treatment, no significant impacts on their performance were observed. Therefore, it can be concluded that conventional WWTP can receive similar WTP residuals as those of the WTP here studied without any negative impacts on their performance.
APA, Harvard, Vancouver, ISO, and other styles
3

Campos, Marlon Caianelo Dias 1986. "Influência da recirculação de água de lavagem de filtros na qualidade da água tratada para consumo humano." [s.n.], 2014. http://repositorio.unicamp.br/jspui/handle/REPOSIP/257942.

Full text
Abstract:
Orientador: Ricardo de Lima Isaac<br>Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo<br>Made available in DSpace on 2018-08-24T14:00:51Z (GMT). No. of bitstreams: 1 Campos_MarlonCaianeloDias_M.pdf: 3410126 bytes, checksum: bb9db3577d3074777f6ae59b1de2ad29 (MD5) Previous issue date: 2014<br>Resumo: A recirculação de água de lavagem de filtro em estação de tratamento de água do tipo convencional (ETA) pode representar economia significativa tanto do recurso hídrico quanto de energia, aspecto fundamental do ponto de vista da sustentabilidade. Contudo, se praticada sem critério, tal prática operacional pode representar risco à saúde do consumidor. O objetivo geral desta pesquisa foi avaliar o impacto da recirculação da água de lavagem de filtros (ALAF) na qualidade da água tratada. O trabalho desenvolveu-se na ETA-3 de Campinas-SP que capta do manancial superficial (rio Atibaia), utiliza pré-cloração e policloreto de alumínio como coagulante no processo de tratamento. Investigou-se em escala de bancada (Jar-test) o impacto da aplicação de taxas de recirculação equivalentes a 2, 4, 6, 8 e 10 % em volume de ALAF em relação ao volume total de água tratada na formação de subprodutos de desinfecção (trihalomeanos e ácidos haloacéticos). Os parâmetros carbono orgânico total (COT), carbono orgânico dissolvido (COD), UV254, turbidez, cor (aparente e verdadeira) e metais (alumínio, bário, cádmio, chumbo, cobre, cromo, manganês, zinco e níquel) foram também avaliados. Em geral, as diferentes taxas de recirculação de ALAF não provocaram inadequações quanto ao padrão de potabilidade para os parâmetros: cor, turbidez, metais (bário, cádmio, chumbo, cobre, cromo, manganês, zinco e níquel) e trihalometanos. Quanto aos ácidos haloáceticos, porém, notou-se que não se atendeu ao valor limite estabelecido na legislação e que o aumento da taxa de recirculação provocou a elevação da concentração deste subproduto da desinfecção na água tratada<br>Abstract: Filter backwash water recycling at conventional water treatment plants (WTP) certainly contributes to water and energy resources rational use, essential for sustainability. However, if practiced without criteria, such operational practice may pose a risk to users¿ health. The overall objective of this research was to evaluate the impact of recirculating filter backwash water on filtered water quality. The work was carried out at Campinas WTP, Sao Paulo State, Brazil. The plant treats surface raw water from Rio Atibaia (pre-chlorination, polyaluminum chloride as main coagulant). It was investigated in lab scale (jar-test) the effect of applying recirculation flowrate corresponding to 2, 4, 6, 8 and 10 % volume of backwash water ratio to total volume of treated water on the formation of disinfection byproducts (trihalomethane, THM and haloacetic acids, HAA). Metals content (aluminum , barium, cadmium, lead, copper, chromium , manganese, zinc and nickel), total organic carbon (TOC), dissolved organic carbon (DOC) , UV254 , turbidity, apparent and true color were also evaluated . In general, tested recirculation rates did not cause filtered water quality mismatches to drinking water standards for the parameters: color, turbidity, metals (barium, cadmium, lead, copper, chromium, manganese, zinc and nickel) and THM. However, for HAA it was found that recycling led to concentration values upper than the maximum contaminant level in Brazilian drinking water standards. Increasing the rate, higher was the concentration of this disinfection by-product in treated water<br>Mestrado<br>Saneamento e Ambiente<br>Mestre em Engenharia Civil
APA, Harvard, Vancouver, ISO, and other styles
4

Silva, Angelica Megda da. "Avaliação da qualidade do Rio São Lourenço, SP, sob influência de estações de tratamento de água e estações de tratamento de esgoto." Universidade de São Paulo, 2008. http://www.teses.usp.br/teses/disponiveis/85/85134/tde-30062009-102128/.

Full text
Abstract:
Durante muito tempo, houve um descaso com os recursos hídricos, tanto por parte da sociedade quanto pelas autoridades. O aumento rápido da população, ocasionando ocupações desordenadas, foi ignorado pelos setores públicos e pela própria sociedade, resultando na degradação do ambiente. Os ensaios ecotoxicológicos são essenciais para avaliação ambiental, em conjunto com a avaliação química e biológica. Atualmente, existem mais de 7500 estações de tratamento de água (ETA) convencionais no Brasil. Estima-se que cerca de 2.000 toneladas de sólidos (lodo gerado após o tratamento) são lançadas em águas brasileiras sem nenhum tratamento. O objetivo do presente trabalho foi a aplicação da tríade de qualidade do sedimento, além da avaliação química e ecotoxicológica da água do Rio São Lourenço, como subsídio para o estudo sobre a influência do descarte de Estações de Tratamento de Água (ETA) e Esgoto (ETE) dos municípios de São Lourenço da Serra e Juquitiba (SP). O Rio São Lourenço, além de abastecer o município de São Lourenço da Serra e receber toda a carga poluidora de São Lourenço da Serra e Juquitiba, é um dos principais afluentes do Rio Juquiá, que faz parte da Bacia Hidrográfica do Vale do Ribeira. Foram realizadas sete coletas durante os anos de 2004, 2005 e 2006, em 12 pontos do Rio São Lourenço, a montante e jusante das estações, as quais incluíram amostragens de água, para análises de parâmetros abióticos e ecotoxicológicos, e sedimento, para avaliação parâmetros ecotoxicológicos. Em 2006 as coletas incluíram amostras de sedimento para avaliação dos parâmetros abióticos e biológicos, dados utilizados para a aplicação da Tríade de Qualidade de Sedimento. Foram utilizadas espécies de diferentes níveis tróficos nos ensaios de ecotoxicidade, principalmente organismos autóctones, como importante ferramenta para se avaliar os ambientes tropicais. Na avaliação da toxicidade, foram realizados ensaios de toxicidade agudos e crônicos da água com Daphnia similis e Daphnia laevis, Ceriodaphnia silvestrii e Ceriodaphnia dubia, e do sedimento com organismos aquáticos: Ceriodaphnia silvestrii, Hyalella azteca e Chironomus xanthus. Nos ensaios ecotoxicológicos agudos foram utilizados para análise estatística o teste de TUKEY (TOXTAT 3.4) e para os ensaios de v toxicidade crônica o método proposto por EPA (2002). Os resultados de setembro de 2006 foram integrados e submetidos a análise multivariada. Os resultados obtidos em São Lourenço da Serra mostraram respostas negativas quanto à comunidade bentônica residente no local. Os pontos críticos quanto a avaliação ecotoxicológica do sedimento foram a jusante da ETA e jusante da ETE, sendo que não foi possível a correlação desses resultados com a avaliação química. Nas amostras de água apresentaram ecotoxicidade os pontos a jusante da ETA e da ETE. Os resultados indicam que o local é influenciado por ações antrópicas além dos descartes das ETA e ETE. Em Juquitiba, foi observada influência da ETA na qualidade da água. Na avaliação da estrutura da comunidade bentônica, a família Tubificidae foi presente e dominante em todos os pontos, característica de ambientes impactados. Na avaliação da contaminação química da água, foram observadas altas concentrações de Al e Fe, sendo que não estão correlacionadas aos efluentes das estações e são características naturais da região de São Paulo. Esses resultados mostram que a qualidade da água e do sedimento do Rio São Lourenço neste local está comprometida pelas ações antrópicas além do ambiente sofrer influência dos descartes das ETA e ETE. Há necessidade de maior controle ambiental na área, já que se trata de uma Área de Preservação Ambiental.<br>For a long time, there was a neglect to water resources, both by society as by the authorities. The rapid increase of population, causing disorderly occupations, was ignored by the public sectors and the society itself, resulting in environmental degradation. Ecotoxicological tests are essential to environmental assessment, together with chemical and biological evaluation. Currently, there are more than 7,500 water treatment plants (WTP) conventional in Brazil. It is estimated that around 2,000 tonnes of solids (sludge generated after treatment) in Brazilian waters are discharged without any treatment. The objective of this work was the application of the triad of quality of the sediment, in addition to chemical and ecotoxicological evaluation of the water of the St. Lawrence River, as a subsidy for the study on the influence of the disposal of water treatment plants (WTP) and Sewage (SWT) of the municipalities of São Lourenço da Serra e Juquitiba (SP). The São Lourenço River, in addition to supplying the city of São Lourenço da Serra and receive all the pollution load of St. Lawrence and the Sierra e Juquitiba is one of the main tributaries of the Rio Juquiá, which is part of Watershed\'s Ribeira Valley. Seven samples were taken during the years 2004, 2005 and 2006, 12 points in the St. Lawrence River, the upstream and downstream of the stations, which included samples of water, for analysis of abiotic parameters and ecotoxicological and sediment for evaluation parameters Ecotoxicological. In 2006 the collection of sediment samples included for evaluation of abiotic and biological parameters, data used for the implementation of the Sediment Quality Triad. The species used in different trophic levels in ecotoxicity testing, mainly indigenous organizations, as an important tool to assess the tropical environments. In the evaluation of toxicity, were tested for acute and chronic toxicity of water with Daphnia similis and Daphnia laevis, Ceriodaphnia silvestrii and Ceriodaphnia dubia, and sediment to aquatic organisms: Ceriodaphnia silvestrii, Hyalella azteca and Chironomus xanthus. In acute ecotoxicological tests were used for statistical analysis of the test TUKEY (TOXTAT 3.4) and for chronic toxicity testing of the method proposed by EPA (2002). The results of September 2006 were included and submitted to multivariate analysis. The achievements of the San Lorenzo Serra showed negative responses on the benthic community resident in the place. The critical points in ecotoxicological assessment of sediment downstream were downstream of WTP and SWT, which was not possible the correlation of these results with the chemical assessment. Samples of water had ecotoxicity points downstream of WTP and SWT. The results indicate that the site is influenced by human actions beyond the disposal of WTP and SWT. In Juquitiba, WTP was observed influence on water quality. In assessing the structure of the benthic community, the family Tubificidae was present and dominant at every point, characteristic of environmental impact. In the evaluation of chemical contamination of water, were found high concentrations of Al and Fe, which are vii not connected to sewage stations and are natural features of the Sao Paulo. These results show that the quality of water and sediment of the St. Lawrence River at this location is committed beyond the influence of environmental disposal of WTP and SWT. There is need for greater environmental control in the area, since this is an area of environmental preservation.
APA, Harvard, Vancouver, ISO, and other styles
5

Lopes, Vanessa Cristina. "Índice para avaliação do desempenho de estações convencionais de tratamento de água." Universidade Federal de Minas Gerais, 2005. http://hdl.handle.net/1843/REPA-6MUHUC.

Full text
Abstract:
This research work aims the proposal of a Water Treatment Plant Quality Index (WTPQI), applied on the conventional plants, to compare the performance of plants by means a methodology beyond compliance Brazilian water standards. The scope of this work is limited to plants with conventional technology of treatment endowed with rectangular settling basins and treating raw water with Brazilian southeastern region typical characteristics, whose objective consists of the water production with tubidity values under 0,5 NTU and total coliforms absence. The WTPQI methodology was divided in three stages and was based on the same utilized for developing the Water Quality Index (WQI). In the first stage a Delphi survey was conducted to pool expert opinion of 18 specialists in water treatment on the relevance of intervening parameters in plants performance. In the second stage, a punctuation criteria had beendeveloped. The third and last stage consisted of the WTPQI application to ten plants of distinct ports located in São Paulo and Minas Gerais.The results of this application have demonstrated a trend of the stations producing filtered water with better quality to be contemplated with bigger WTPQI values. This fact showed the usefulness of the index as a tool able to help water supply systems management.<br>O presente trabalho tem como objetivo a proposição de um Índice de Qualidade da Estação de Tratamento de Água IQETA que permita às administrações de sistemas de abastecimento comparar o desempenho das estações por meio de uma metodologia que transcenda o simples atendimento ao padrão de potabilidade vigente.O universo deste trabalho limitou-se a estações com tecnologia convencional de tratamento, dotadas de decantadores de escoamento horizontal, tratando água bruta com características típicas da região sudeste, cujo objetivo consiste na produção de água tratada com turbidez inferior a 0,5 uT e ausência de coliformes totais conforme Portaria 518/04. A metodologia para a elaboração do IQETA foi dividida em três etapas sendo fundamentada basicamente na mesma utilizada para o desenvolvimento do IQA (Índice de Qualidade daÁgua). Na primeira etapa foram levantados por meio de uma pesquisa de opinião aplicada a um grupo de 18 especialistas da área de tratamento de tratamento de água, os parâmetros intervenientes no desempenho das estações com tecnologia de tratamento convencional bem como seus respectivos pesos. Esta pesquisa seguiu as características da metodologia Delphi como o anonimato, o feedback e a representação estatística dos resultados. Na segunda etapa do trabalho foram desenvolvidos critérios de pontuação a partir das recomendações da ABNT (1992). A terceira e última etapa constituiu-se da aplicação do IQETA a dez estações de portes distintos dos estados de São Paulo e Minas Gerais. Os resultados desta aplicação demonstraram uma tendência das estações produzindo água filtrada de melhor qualidade, no que se refere a valores de turbidez, serem contempladas commaiores valores para o IQETA. No entanto as baixas correlações entre o IQETA e os valores de turbidez indicam a possibilidade de utilização do índice como uma ferramenta capaz de auxiliar na administração de sistemas de produção de água, uma vez que é composto deparâmetros complementares aos indicadores de desempenho normalmente utilizados, como por exemplo, a turbidez.
APA, Harvard, Vancouver, ISO, and other styles
6

Oliveira, Nicole Santos. "Estudo da secagem de lodo de estação de tratamento de água." reponame:Repositório Institucional da UFPR, 2011. http://hdl.handle.net/1884/26186.

Full text
Abstract:
Resumo: O desaguamento do lodo tem como objetivo a redução do volume, para facilitar ou mesmo possibilitar o transporte e/ou disposição final dos resíduos do tratamento. Tal processo é realizado nas operações de desidratação, as quais podem ser realizadas por sistemas mecânicos e naturais. Os leitos de secagem, sistemas de fácil operação e econômicos, são constituídos por camada suporte, meio filtrante e sistema de drenagem. A desidratação através da centrifugação ocorre através de um processo, no qual são aplicadas forças centrífugas ao lodo, para acelerar a separação das fases líquidas e sólidas. Este trabalho teve como objetivo estudar a secagem do lodo: de forma natural, através de leitos de secagem pilotos convencionais e alternativos; e mecanizada, através de centrífugas em escala real e de bancada. Para isto, foram utilizados leitos de secagem piloto instalados na ETA Iguaçu, sendo: 3 leitos de secagem convencionais (meio granular), 2 leitos de secagem alternativos com geotêxtil não-tecido bidim e 2 leitos de secagem alternativos com geotecido. Para o estudo da centrifugação foram utilizadas: centrífugas do tipo decanter, instaladas nas ETA Iraí e ETA Passaúna; e centrífuga de laboratório, no LABEAM da UFPR. Para caracterizar o lodo utilizado na pesquisa, a qualidade do clarificado e estudar a eficiência da desidratação e foram avaliados os parâmetros: pH, condutividade, turbidez, cor, série de sólidos, sólidos sedimentáveis, demanda química de oxigênio, alumínio e óleos e graxas. Dados climatológicos diários obtidos através do INMET foram utilizados, para uma melhor avaliação do processo de secagem do lodo. Como resultados, após 30 dias, para os leitos convencionais foram obtidos teores de até 40%, para os leitos alternativos com bidim de 17 à 27% e leitos alternativos com geotecido de 5 à 7%, como ST. Conclui-se que a predominância de baixas temperaturas, altos índices de umidade e grande volume de precipitação durante os 2 ciclos, não favoreceram a secagem do lodo. As características da água drenada nos leitos mostraram que o sistema possui excelente condição de clarificação, constatou-se efetiva remoção de sólidos, alumínio e DQO. Foram encontrados teores médios de 14% de ST para o lodo centrifugado da ETA Passaúna e Iraí. A mediana do rendimento da centrifugação para o lodo da ETA Iraí foi de 95%, e para a ETA Passaúna, 94%. A baixa desidratabilidade do lodo da ETA Iraí é pela presença de algas na água bruta e baixa eficiência do flotador, e na ETA Passaúna, pela presença de materiais finos e baixa eficiência do adensador. A dosagem ótima obtida no estudo de centrifugação em escala de bancada foi de 4 g/kg de SST. Verificou-se que o tempo ideal para a realização do ensaio foi de 30 minutos e que, quanto maior a rotação imposta, maior a concentração de ST na torta de lodo.
APA, Harvard, Vancouver, ISO, and other styles
7

Souza, Maria Eugenia Tavares Abreu de. "Proposição de um índice de qualidade da água bruta afluente a estações convencionais de tratamento de água." Universidade Federal de Minas Gerais, 2008. http://hdl.handle.net/1843/REPA-7QUF25.

Full text
Abstract:
The proposition of a raw water quality index applying to conventional water treatment plants (RWQI) will allow evaluating the efficiency of the plant, not only concerning the water quality for public supply according to drinking water standard. Consequently, the natural water that presents high values of RWQI and WTPQI could not have the same efficiency of waters with low RWQI, meaning waters with lower quality with the same WTPQI value. The main objective of the proposition is to show the utility of this rate as a tool for systems of operation and production of potable water and for public information of the water quality as well. This research was made according the Delphi methodology, with help of specialists in the definition of weights and in the choice of quality parameters for the raw water to be used in theproposition of this index. Two questionnaires was sent to specialists. The first had the answers of weight and parameters, and the second had the feedback of the answers of the first one. Then the parameters scoring was structured, after the most relevant weights and parameters were determined according with the specialists opinion. This scoring was structured considering the impact occasioned in water treatment by the variation in parameters concentration. The optimum values of a parameter must have higher values in the parameter scoring, as low values must have lower values. The parameters scoring were determined after consulting bibliography, legislation and inquiring operators and researchers about the process of water supply potabilization. The last stage of this work was a mathematic formulation of the productory and somatory for aggregation of all variables to propose the RWQI and utilization of the rate in a conventional water treatment station. The productory was used to verify the influence of lower scoring parameters in rate values. The (RWQI) is an important information tool for the quality water sources like common stage that evaluates the performance from water treatment plants.<br>A proposição de um índice de qualidade da água bruta afluente a estações de tratamento de água convenciais (IQAB) permitirá avaliar a eficiência do tratamento de água em função não somente do cumprimento dos padrões de qualidade de água para abastecimento público ditados pela Portaria 518/04 (MINISTÉRIO DA SAÚDE, 2004) e do Índice de Qualidade de Estações de Tratamento de Água (IQETA), mas também em função das características da água bruta afluente a estação de tratamento. O principal objetivo da proposição deste índice é demonstrar sua utilidade como ferramenta capaz de auxiliar em sistemas de operação e produção de água potável, bem como para objeto de informação pública da qualidade da água em mananciais de abastecimento. O desenvolvimento da pesquisa foi feito através da metodologia Delphi com a opinião de especialistas para a definição dos pesos e escolha dos parâmetros de qualidade da água bruta a serem abordados para a proposição do índice. Foram enviados aos participantes dois questionários de pesquisa de opinião, o último contendo o feedback das respostas do primeiro para verificação dos pesos e parâmetros, visando um consenso nas opiniões. Após a definição dos pesos e dos parâmetros mais relevantes, foram desenvolvidas pontuações dos parâmetros, levando em consideração o impacto produzido no tratamento de água pelas variações nos valores do parâmetro. A pontuação dos parâmetros foi determinada através de consultas à literatura, questionamentos a operadores e pesquisadores sobre a potabilização das águas de abastecimento, bem como a legislação pertinente. A última etapa do trabalho foi a formulação matemática através de um produtório e somatório para agregação de todas as variáveis para a proposição do IQAB e aplicação do índice para uma estação de tratamento convencional. Por fim, a utilização do produtório foi aplicada para a observação da relevância dos parâmetros de pontuações mais baixas na interferência de valores do índice. O IQAB é uma importante ferramenta de informação da qualidade da água de mananciais como etapa rotineira na performance de sistemas de abastecimento.
APA, Harvard, Vancouver, ISO, and other styles
8

Acquolini, Gabriela Tirello. "Caracterização do lodo de estações de tratamento de água de Porto Alegre/RS." reponame:Biblioteca Digital de Teses e Dissertações da UFRGS, 2017. http://hdl.handle.net/10183/178440.

Full text
Abstract:
O grande adensamento antrópico nas metrópoles tem aumentado a contaminação e a poluição dos recursos hídricos, que na maioria das vezes abastecem esta mesma população. Com isso, o saneamento básico e seus resíduos relacionados, como o lodo das Estações de Tratamento de Água (ETA) devem ter uma destinação ambientalmente adequada, uma vez que possuem na sua composição predominantemente orgânica, agrotóxicos, metais e produtos químicos. Desta forma, o objetivo desse estudo foi caracterizar o lodo residual de duas estações de tratamento de água do município de Porto Alegre (RS), por meio de análises químicas, biológicas e físicas do lodo, assim como determinar o efeito do lodo em plantas ornamentais a partir da sua disposição no solo. Em complementação foi também realizado a avaliação de alguns parâmetros de qualidade da água do manancial de captação: Guaíba. O lodo foi submetido a análises laboratoriais para diagnóstico de presença de metais, agrotóxicos, coliformes fecais, bem como análises microscópicas e de difratometria de raios X. Além disso, o lodo foi disposto em um Latossolo, com o cultivo de duas espécies ornamentais: Cynodon dactylon e Lobularia marítima (L.) Desv. Também foram realizadas análises de alguns parâmetros de qualidade da água em 28 pontos do Guaíba. Os resultados da análise do lodo residual de duas ETAs identificaram elevadas concentrações de carbono orgânico e de coliformes fecais e não houve detecção de agrotóxicos, classificando o lodo como resíduo Classe II-A – Não-inerte. O uso diluído de lodo no solo em diferentes concentrações não influenciou significativamente a produção de matéria seca de Cynodon dactylon e Lobularia marítima (L.) Desv. A água no lago Guaíba apresenta diferentes níveis de qualidade, sendo que a região mais ao norte do lago apresenta uma qualidade inferior à região sul, que se aproxima da foz. A região próxima ao centro de Porto Alegre é onde a qualidade da água é menor, com destaque para a presença de coliformes fecais em grande quantidade. Entre as fontes de poluição pontual destaca-se a contribuição do Arroio Dilúvio.<br>The population increase in the big cities has increased contamination and pollution of water resources, which usually could be used to supply this same population. Basic sanitation and its related waste, such as water treatment plant sludge (ETA), must have an environmentally appropriate destination, since they have predominantly organic composition, agrochemicals, metals and chemicals. Thus, the objective of this study was to characterize the residual sludge from two water treatment plants in the city of Porto Alegre (RS), by means of the Guaíba water quality assessment, using chemical, biological and physical analyzes of the sludge as well to determine the effect of sludge addiction to the soil on ornamental plants growth. The sludge was subjected to laboratory analysis to diagnose the presence of metals, pesticides, fecal coliforms, as well as microscopic analysis and X-ray diffraction. In addition, the sludge was disposed in an Oxisol, with the cultivation of two ornamental plants: Cynodon Dactylon and Lobularia maritime (L.) Desv. Guaíba water quality analyzes were also carried out. The results of the residual sludge analysis of two ETAs identified high concentrations of organic carbon and fecal coliforms and no pesticides were detected, classifying the sludge as Class II-A non-inert residue. The diluted use of soil sludge in different concentrations not influenced significantly the dry matter production of Cynodon dactylon and Lobularia maritime (L.) Desv. The water in Lake Guaíba presents different levels of quality, being that the region more to the north of the lake presents a inferior quality to the south region, that approaches the mouth. The region near the downtown of Porto Alegre is more polluted and the quality of water is lower, especially by the presence of fecal coliforms in great quantity. Dilúvio strem is among the main punctual sources of pollution of the Guaiba Lake.
APA, Harvard, Vancouver, ISO, and other styles
9

Rocha, André Luiz Marques. "Desempenho de estações de tratamento de águas cinzas e negras para residências rurais, envolvendo filtros orgânicos e reatores solares." Universidade Federal de Viçosa, 2013. http://www.locus.ufv.br/handle/123456789/10448.

Full text
Abstract:
Submitted by Reginaldo Soares de Freitas (reginaldo.freitas@ufv.br) on 2017-05-31T12:27:30Z No. of bitstreams: 1 texto completo.pdf: 2353197 bytes, checksum: c7857ff947a3da3dfb17abdaa73dd50c (MD5)<br>Made available in DSpace on 2017-05-31T12:27:30Z (GMT). No. of bitstreams: 1 texto completo.pdf: 2353197 bytes, checksum: c7857ff947a3da3dfb17abdaa73dd50c (MD5) Previous issue date: 2013-02-04<br>Conselho Nacional de Desenvolvimento Científico e Tecnológico<br>A água de reuso é uma opção promissora do ponto de vista ambiental, já que contribui para diminuição da captação e consequentemente redução nas vazões de lançamento de efluentes. O lançamento de águas cinzas e águas negras sem tratamento no ambiente deprecia a qualidade de vida das populações em função do surgimento de várias doenças. O presente trabalho objetivou monitorar e avaliar a eficiência de uma estação de tratamento de águas cinzas (ETAC) e de uma estação de tratamento de águas negras (ETAN), visando o reaproveitamento não-potável das águas cinzas e das águas negras em comunidades rurais de baixa renda. A ETAC foi montada na comunidade rural Macena, no município de Viçosa-MG. Tal sistema era constituído de biofiltro, reatores solares e sumidouro, o qual foi monitorado no período de 23 de julho de 2009 a 01 de outubro de 2009. As análises físico-químicas e microbiológicas dos efluentes foram realizadas em distintos pontos do sistema para avaliação do desempenho. A ETAC foi montada no Delineamento Inteiramente Casualizado com três tratamentos (pontos de amostragem) e cinco repetições no tempo. De acordo com os resultados obtidos durante a avaliação da estação de tratamento de águas cinzas (ETAC), conclui-se que a (ETAC) proporcionou eficiências médias de remoções de 28%, 56%, 71,3%, 76,5%, 52,5%, 71%, 61%, 4,6% e 87% nas concentrações de Condutividade Elétrica (CE), Turbidez (TB), Demanda Química de Oxigênio (DQO), Demanda Bioquímica de Oxigênio (DBO), Sólidos Totais (ST), Sólidos Suspensos Totais (SST), Fósforo Total (P total ), Nitrogênio Total (N total ) e Óleos e Graxas (OG), respectivamente. Com relação às características microbiológicas, a ETAC obteve uma eficiência de remoção média de E. coli de 3 unidades logarítmicas. A ETAN foi montada na comunidade rural de Água Limpa do município de Cajuri-MG. Tal sistema foi constituído de caixa de gordura, tanque séptico, biofiltro, reatores solares e sumidouro, o qual foi monitorado no período de 7 de maio de 2009 a 25 de junho de 2009. As análises físico-químicas e microbiológicas dos efluentes foram realizadas em distintos pontos do sistema para avaliação do desempenho. O experimento para tratamento de águas negras foi montado no Delineamento Inteiramente Casualizado com quatro tratamentos (pontos de amostragem) e seis repetições no tempo. De acordo com os resultados obtidos durante a avaliação da estação de tratamento de águas negras (ETAN), conclui-se que a (ETAN) proporcionou eficiências médias de remoções de 46%, 88%, 78,2%, 85,8%, 61,5%, 91%, 75%, 14,4% e 67,8% nas concentrações de Condutividade Elétrica (CE), Turbidez (TB), Demanda Química de Oxigênio (DQO), Demanda Bioquímica de Oxigênio (DBO), Sólidos Totais (ST), Sólidos Suspensos Totais (SST), Fósforo Total (P total ), Nitrogênio Total (N total ) e Óleos e Graxas (OG), respectivamente. Com relação às características microbiológicas, a ETAN proporcionou uma eficiência de remoção média de E. coli de 2 unidades logarítmicas.<br>The water reuse is a promising alternative for the viewpoint of the environment, contributing to reduced absorption and reduces the flow of effluent discharge. The release of greywater and untreated sewage depreciates environmental quality of life of populations due to the onset of various diseases. This study aimed to monitor and evaluate the capacity of a treatment plant for greywater and a treatment of sewage, for non-potable reuse of greywater and blackwater in communities low-income rural. The treatment plant grey water was set up in the rural community Macena in Viçosa-MG. This system consists of biofilters, solar reactors and sinkhole, which was controlled in the period from July 23, 2009 to October 1, 2009. The physico-chemical and microbiological characteristics of the effluents were realized in different parts of the performance evaluation system. The treatment plant greywater was mounted in a completely randomized design with three treatments (sampling points) and five replications in time. According to the results obtained during the evaluation of the water treatment station ash, it is concluded that this treatment stationgave mean elimination efficiency of 28%, 56%, 71.3%, 76.5 %, 52.5%, 71%, 61%, 4.6% and 87% concentrations of electrical conductivity, turbidity, chemical oxygen demand, biochemical oxygen demand, total solids, total suspended solids, total phosphorus, total oil and grease, nitrogen, respectively. Regarding the microbiological characteristics, the treatment plant greywater obtained an average efficiency of removal of E. coli three logarithmic units.The station blackwater treatment was mounted in the rural community of Água Limpa, in Cajuri-MG.This system consisted of the grease trap, septic tank, biological filter, solar reactors and the sinkhole, which is monitored in the period from May 7, 2009 to June 25, 2009. The physico-chemical and microbiological characteristics of the effluents were carried out in different parts of the performance evaluation system. Experience in wastewater treatment was mounted in a completely randomized design with four treatments (sampling points) and six replications in time. According to the results obtained during the evaluation of treatment plant sludge, is follows that a gave mean elimination efficiency of 46%, 88%, 78.2%, 85.8%, 61.5%, 91%, 75%, 14.4% and 67.8% to levels of electrical conductivity, turbidity, chemical oxygen demand, biochemical oxygen demand, total solids, total suspended solids, total phosphorus, nitrogen total, oil and grease, respectively. Regarding the microbiological characteristics, the station blackwater treatment obtained an average efficiency of removal of E. coli two logarithmic units.
APA, Harvard, Vancouver, ISO, and other styles
10

Chaves, Karina Oliveira. "Desenvolvimento e aplicação de sistema de floco-flotação por ar dissolvido para tratamento da água de lavagem do filtro da ETA Gavião." reponame:Repositório Institucional da UFC, 2012. http://www.repositorio.ufc.br/handle/riufc/3801.

Full text
Abstract:
CHAVES, K. O. Desenvolvimento e aplicação de sistema de floco-flotação por ar dissolvido para tratamento da água de lavagem do filtro da ETA Gavião. 2012. 125 f. Dissertação (Mestrado em Engenharia Civil) - Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2012.<br>Submitted by Marlene Sousa (mmarlene@ufc.br) on 2012-09-13T17:27:18Z No. of bitstreams: 1 2012_dis_kochaves.pdf: 3780564 bytes, checksum: c01f7a9b02759238448368189535643a (MD5)<br>Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2012-09-25T14:04:58Z (GMT) No. of bitstreams: 1 2012_dis_kochaves.pdf: 3780564 bytes, checksum: c01f7a9b02759238448368189535643a (MD5)<br>Made available in DSpace on 2012-09-25T14:04:58Z (GMT). No. of bitstreams: 1 2012_dis_kochaves.pdf: 3780564 bytes, checksum: c01f7a9b02759238448368189535643a (MD5) Previous issue date: 2012<br>In Brazil the filter backwash wastewater is normally released in to the water resources without proper treatment, representing a potential danger to the environment. Thus, it is necessary to treat this wastewater in order to dispose it in accordance to federal and state environmental laws. Studies show that Dissolved Air Flotation (DAF) technology has been feasible for this purpose. It is believed that the incorporation of flocculation in curtains and air dissolved flotation system in the same unit can promote high efficiency and significant size reduction, which translates in a technological innovation: the Floculator - Dissolved Air Flotation (FFAD) unit. A FFAD pilot unit was built to evaluate the treatment of Gavião Water Treatment Plant filter backwash wastewater, owned by the Water and Wastewater Company of Ceará (CAGECE). This research had as main objective to quantify and verify the compliance of the filter backwash wastewater parameters to the Resolution No. 430/11 and 357/05 of CONAMA and Ordinance No. 154/2002 of SEMACE. Treatability studies were performed with filter backwash wastewater using Jartest to evaluate the influence of cationic polymer dosages and the feasibility of decreasing flocculation velocity gradients (35 to 5.6 s-1) in the FFAD. Experimental runs of the flocculation - flotation system were performed to evaluate the best polymer dosage and the process parameters such as recirculation rates (TR) and surface application rates (TAS). These parameters were compared by observing the lower residual turbidity and best removal efficiency in the clarified water (AC). The treated wastewater was again characterized using physicalchemical and bacteriological parameters and compared to the specific legislation. The results showed that the use of 1 mg.L-1 of polymer, recirculation rate of 15% and surface application rate of 57 m3.m-2.d-1, presented the highest turbidity efficiency removal (> 98%) and a very stable performance against sudden changes in the influent quality (94.4 to 410UT). It should be noted that the unity showed also a high average efficiency total coliforms removal (98.5%), apparent color removal (97.6%), DOC removal (92.6%), of aluminum (84.1%) removal and turbidity (99.2 %) removal. Given these results, it was concluded that the AC coming from the treatment of ALF by ETA WTP Gavião FFAD met the discharge parameters listed for water resources.<br>No cenário brasileiro, os resíduos de Estações de Tratamento de Água (ETAs) são normalmente lançados in natura em corpos hídricos, apresentando-se como potencialmente danosos ao meio ambiente, sendo necessário tratá-los para que sejam descartados conforme os aspectos legais. Estudos demonstram que a tecnologia da Flotação por Ar Dissolvido (FAD) tem sido viável para este fim. Acredita-se que a incorporação da floculação em cortinas numa mesma unidade de flotação possa promover elevada eficácia ao sistema, traduzindo-se como uma inovação tecnológica: o Floco-Flotador por Ar Dissolvido (FFAD). Uma unidade piloto de FFAD foi construída para o tratamento da água de lavagem dos filtros da ETA Gavião, pertencente à Companhia de Água e Esgoto do Ceará (CAGECE). Esta pesquisa teve como objetivo quantificar e verificar o atendimento da água de lavagem dos filtros (ALF) desta ETA e da água clarificada via FFAD aos padrões de lançamento de efluentes conforme as Resoluções nº 430/11 e 357/05 do CONAMA e Portaria nº 154/2002 da SEMACE. Estudos de tratabilidade da ALF em Jartest foram realizados para avaliar a influência da dosagem de polímeros catiônicos e a viabilidade de gradientes de velocidade decrescente (35 a 5,6 s-1) a serem empregados no equipamento de FFAD desenvolvido. Ensaios de flotação foram realizados a fim de avaliar a dosagem do polímero e os parâmetros de processo como taxas de recirculação (TR) e taxas de aplicação superficial (TAS). Após definidos estes parâmetros, ensaios de FFAD foram realizados em triplicata para coleta da AC a fim de compará-la com os principais padrões de lançamento de efluente em corpos hídricos classe II. Somente os parâmetros pH, Fluoreto, Amônia, E. coli e Sólidos dissolvidos da ALF atenderam aos padrões de lançamento. Ao aplicar polímero a 1 mg.L-1, taxa de recirculação de 15%, gradientes de velocidade decrescente (19,3 a 5,6 s-1), taxa de aplicação superficial de 57 m3.m-2.d-1 com tempo de detenção hidráulico de 22 minutos no FFAD, os resultados alcançaram elevada eficiência na remoção de turbidez (superior a 98%) mesmo enfrentando variações bruscas na qualidade da ALF (94,4 a 410 UT). Observou-se também significativa eficiência média na remoção de coliformes totais (98,5%), cor aparente (97,6%), DQO (92,6%) e remoção de alumínio (84,1%). Diante destes resultados, constatou-se que a ALF da ETA Gavião tratada via Floco-flotação por ar dissolvido atendeu aos referidos padrões de lançamento em corpos hídricos.
APA, Harvard, Vancouver, ISO, and other styles
11

Galrão, Divanildes da Silva. "Preservação de efluentes para analise de carbono organico dissolvido." [s.n.], 2003. http://repositorio.unicamp.br/jspui/handle/REPOSIP/258102.

Full text
Abstract:
Orientadores: Jose Roberto Guimarães<br>Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil<br>Made available in DSpace on 2018-08-03T19:05:03Z (GMT). No. of bitstreams: 1 Galrao_DivanildesdaSilva_M.pdf: 1700452 bytes, checksum: 00008e31bdce85af5b908dfa92cf19fd (MD5) Previous issue date: 2003<br>Mestrado
APA, Harvard, Vancouver, ISO, and other styles
12

Souza, Weverton Gesiel de. "Pós-secagem natural de lodos de estações de tratamento de água e esgoto sanitários." Universidade de São Paulo, 2012. http://www.teses.usp.br/teses/disponiveis/3/3147/tde-04072013-170307/.

Full text
Abstract:
Os processos de secagem de resíduos produzidos em estações de tratamento de água e esgoto por processos mecânicos podem gerar lodos com teores de sólidos de 20% a 30%, podendo estes variar de acordo com as características do lodo bem como da tecnologia de desidratação. Uma vez que os custos de transporte e disposição final têm aumentado de forma significativa para lodos produzidos em regiões metropolitanas, torna-se atrativo a sua redução mediante o aumento do teor de sólidos do lodo desidratado. Desta forma, este trabalho teve por objetivo avaliar o processo de pós-secagem de resíduos gerados em estações de tratamento de água (ETA) e esgoto (ETE) por processos naturais, tendo-se avaliado a influência das condições climáticas da cidade de São Paulo para diferentes estações do ano. O estudo foi realizado com dois tipos de leitos de secagem em escala piloto; leito coberto (LC) e leito aberto (LA), tendo os mesmos 1,80m2 de área e piso impermeabilizado. Os dados hidrometeorológicos foram obtidos mediante a operação de uma estação hidrometeorológica portátil que forneceu dados de temperatura do ar e do lodo, umidade relativa do ar, radiação solar global, velocidade do vento e precipitação. O lodo gerado nas estações de tratamento foram dispostos nos leitos de secagem em leiras com 30cm de altura, sendo revolvidos e realizadas análises de teor de sólidos do lodo três vezes por semana, o período de secagem de cada ciclo foi de 30 dias. Os teores de sólidos dos lodos obtidos nos ensaios com pós-secagem natural apresentaram resultados distintos para diferentes períodos do ano; durante o período do verão foi obtido lodo com teor de sólido final de 58% médio, enquanto, no período de inverno foi obtido lodo com teor de sólido final de 18% médio. Foi utilizado um modelo matemático para o processo de secagem do lodo utilizando os dados meteorológicos medidos, uma equação do balanço de calor foi aplicada para o volume de controle do leito de secagem do lodo considerando a transferência de calor por radiação, convecção, e evaporação.<br>The mechanical drying process of residuals produced in water and wastewater treatment plants can generate sludge with solids content of 20% to 30%. These values may vary according to the characteristics of the sludge and dehydration technology. The costs of sludge produced in metropolitan areas have increased significantly due to transportation and final disposal. Hence, it is to, becoming attractive to reduce the residue volume by increasing the solids content of the dewatered sludge. This study aimed to evaluate the process of post drying of residues generated in water wastewater treatment plants (WTP and WWTP) by natural processes, evaluating the influence seasonal variation of the weather in the São Paulo city. The study was conducted with two drying beds on a pilot scale; one being a cover unit (CU) and the other an uncover unit (UU). Both units have the same area of 1.80m2 and waterproof floor. The hydrometeorological data were obtained through the operation of a weather station installed close to the units that supplied data for temperature of the air and sludge, relative humidity, solar radiation, wind speed and precipitation. The sludge source in the treatment stations are arranged in the drying beds to ridges with 30cm height, the sludge was mixed and analyzed of solid content three times a week, the drying time of each cycle was 30 days. The solid content of the sludge obtained in tests with post drying by natural processes showed different results for different seasonal of the year and during the summer period was obtained sludge with solid content finale average of 58%, while in the winter was obtained sludge with solid content finale average of 18%. A mathematical model is developed for the process of drying of sludge, a heat-balance equation is applied for a control volume of sludge that takes into account the heat transfer by radiation, convection, and evaporation.
APA, Harvard, Vancouver, ISO, and other styles
13

Botero, Wander Gustavo [UNESP]. "Caracterização de lodo gerado em estações de tratamento de água: perspectivas de aplicação agrícola." Universidade Estadual Paulista (UNESP), 2008. http://hdl.handle.net/11449/97748.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:29:06Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-01-18Bitstream added on 2014-06-13T18:38:44Z : No. of bitstreams: 1 botero_wg_me_araiq.pdf: 512153 bytes, checksum: b09f40251aab07169471a9ef398cbac7 (MD5)<br>Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)<br>Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)<br>Este trabalho caracterizou lodos gerados em estações de tratamento de água de Jaboticabal-SP que utiliza cloreto férrico como floculante (FeCl3) e de Taquaritinga-SP e Manaus-AM, que utilizam sulfato de alumínio (Al2(SO4)3) como floculante. Foram feitas análises para avaliação da fertilidade, análise elementar e determinação de micro e macro-nutrientes e metais potencialmente tóxicos totais e biodisponíveis. Os resultados mostraram que os lodos apresentam potencial agrícola e elevados teores de matéria orgânica, sendo maiores para o lodo de Manaus-AM, que apresentou também maior grau de decomposição da matéria orgânica. Os teores de macro e micro-nutrientes e metais potencialmente tóxicos e biodisponiveis estão diretamente relacionados com o tipo de floculante utilizado no tratamento convencional da água e nas características da água bruta captada. As substâncias húmicas extraídas dos lodos de estações de tratamento de água (ETA) foram caracterizadas por análise elementar e análise térmica, apresentando para amostra de Manaus-AM maior grau de humificação. A estabilidade térmica se apresentou dependente do tipo de tratamento utilizado no lodo. Os estudos de complexação mostraram cinética de 10 minutos para íons cobre. Pela capacidade de complexação pode-se estabelecer a seguinte ordem de afinidade das SH por espécies metálicas:. Lodo de estação de tratamento de água de Jaboticabal-SP: Fe<Al<Ca<Cu<Mn<Mg;. Lodo de estação de tratamento de água de Taquaritinga-SP: Mn<Al<Ca<Cu<Fe<Mg; . Lodo de estação de tratamento de água de Manaus-AM: Mn<Al<Cu<Ca<Fe<Mg. As labilidade relativas tiveram o equilíbrio de troca atingido após 1 hora de contato e foram menores para lodos de Manaus-AM e o magnésio apresentou a menor labilidade relativa frente ao quelante dietilenotriaminopentaacético (DTPA)...<br>This work characterized sludge discharges from water treatment plants at the town Jaboticabal, São Paulo, Brazil using ferric chloride (FeCl3) as clotting and at the town Taquaritinga, São Paulo, Brazil and Manaus, Amazonas, Brazil, using aluminum sulfate (Al2 (SO4)3) as clotting. Tests were made for fertility, elemental analysis and determination of micro and macro-nutrients and potentially toxic metals. The results showed that the sludge present agricultural potential and high levels of organic matter, and higher for the sludge of Manaus-AM, which has also presented greater degree of decomposition of organic matter. The levels of macro and micronutrients and potentially toxic metals and bioavailable are directly related to the type of clotting used in the conventional treatment of water and the characteristics of water. Humic substances from the sludges generated in water treatment plants were characterized by elemental analysis and thermal analysis, presenting to sample Manaus-AM greater degree of humification. The thermal stability came dependent on the type of treatment used in the sludge. Studies of complexation showed kinetics of 10 minutes for copper ions. For the ability to complexation one can establish the following order of affinity of humic substances by metallic ions: . Sludge generated in water treatment plants of Jaboticabal-SP: Fe <Al <Ca <Cu <Mn <Mg;This work characterized sludge discharges from water treatment plants at the town Jaboticabal, São Paulo, Brazil using ferric chloride (FeCl3) as clotting and at the town Taquaritinga, São Paulo, Brazil and Manaus, Amazonas, Brazil, using aluminum sulfate (Al2 (SO4)3) as clotting. Tests were made for fertility, elemental analysis and determination of micro and macro-nutrients and potentially toxic metals. The results showed that the sludge present agricultural potential and high levels of organic matter, and higher...(Complete abstract, click electronic access below)
APA, Harvard, Vancouver, ISO, and other styles
14

Botero, Wander Gustavo. "Caracterização de lodo gerado em estações de tratamento de água : perspectivas de aplicação agrícola /." Araraquara : [s. n.], 2008. http://hdl.handle.net/11449/97748.

Full text
Abstract:
Resumo: Este trabalho caracterizou lodos gerados em estações de tratamento de água de Jaboticabal-SP que utiliza cloreto férrico como floculante (FeCl3) e de Taquaritinga-SP e Manaus-AM, que utilizam sulfato de alumínio (Al2(SO4)3) como floculante. Foram feitas análises para avaliação da fertilidade, análise elementar e determinação de micro e macro-nutrientes e metais potencialmente tóxicos totais e biodisponíveis. Os resultados mostraram que os lodos apresentam potencial agrícola e elevados teores de matéria orgânica, sendo maiores para o lodo de Manaus-AM, que apresentou também maior grau de decomposição da matéria orgânica. Os teores de macro e micro-nutrientes e metais potencialmente tóxicos e biodisponiveis estão diretamente relacionados com o tipo de floculante utilizado no tratamento convencional da água e nas características da água bruta captada. As substâncias húmicas extraídas dos lodos de estações de tratamento de água (ETA) foram caracterizadas por análise elementar e análise térmica, apresentando para amostra de Manaus-AM maior grau de humificação. A estabilidade térmica se apresentou dependente do tipo de tratamento utilizado no lodo. Os estudos de complexação mostraram cinética de 10 minutos para íons cobre. Pela capacidade de complexação pode-se estabelecer a seguinte ordem de afinidade das SH por espécies metálicas:. Lodo de estação de tratamento de água de Jaboticabal-SP: Fe<Al<Ca<Cu<Mn<Mg;. Lodo de estação de tratamento de água de Taquaritinga-SP: Mn<Al<Ca<Cu<Fe<Mg; . Lodo de estação de tratamento de água de Manaus-AM: Mn<Al<Cu<Ca<Fe<Mg. As labilidade relativas tiveram o equilíbrio de troca atingido após 1 hora de contato e foram menores para lodos de Manaus-AM e o magnésio apresentou a menor labilidade relativa frente ao quelante dietilenotriaminopentaacético (DTPA)...(Resumo completo, clicar acesso eletrônico abaixo)<br>Abstract: This work characterized sludge discharges from water treatment plants at the town Jaboticabal, São Paulo, Brazil using ferric chloride (FeCl3) as clotting and at the town Taquaritinga, São Paulo, Brazil and Manaus, Amazonas, Brazil, using aluminum sulfate (Al2 (SO4)3) as clotting. Tests were made for fertility, elemental analysis and determination of micro and macro-nutrients and potentially toxic metals. The results showed that the sludge present agricultural potential and high levels of organic matter, and higher for the sludge of Manaus-AM, which has also presented greater degree of decomposition of organic matter. The levels of macro and micronutrients and potentially toxic metals and bioavailable are directly related to the type of clotting used in the conventional treatment of water and the characteristics of water. Humic substances from the sludges generated in water treatment plants were characterized by elemental analysis and thermal analysis, presenting to sample Manaus-AM greater degree of humification. The thermal stability came dependent on the type of treatment used in the sludge. Studies of complexation showed kinetics of 10 minutes for copper ions. For the ability to complexation one can establish the following order of affinity of humic substances by metallic ions: . Sludge generated in water treatment plants of Jaboticabal-SP: Fe <Al <Ca <Cu <Mn <Mg;This work characterized sludge discharges from water treatment plants at the town Jaboticabal, São Paulo, Brazil using ferric chloride (FeCl3) as clotting and at the town Taquaritinga, São Paulo, Brazil and Manaus, Amazonas, Brazil, using aluminum sulfate (Al2 (SO4)3) as clotting. Tests were made for fertility, elemental analysis and determination of micro and macro-nutrients and potentially toxic metals. The results showed that the sludge present agricultural potential and high levels of organic matter, and higher...(Complete abstract, click electronic access below)<br>Orientador: Ademir dos Santos<br>Coorientador: Julio Cesar Rocha<br>Banca: Nilso Barelli<br>Banca: Maria Olímpia de Oliveira Resende<br>Mestre
APA, Harvard, Vancouver, ISO, and other styles
15

Moraes, Beatriz Stoll. "Utilização de lodos de estações de tratamento de água como fonte alternativa de energia." reponame:Biblioteca Digital de Teses e Dissertações da UFRGS, 2018. http://hdl.handle.net/10183/183056.

Full text
Abstract:
O lodo é o principal resíduo sólido gerado no processo de Tratamento de Água para Abastecimento público (ETA). São considerados Resíduos Sólidos Não Perigosos e Não Inertes (Classe IIA) pela ABNT 10.004/2004, devendo ser tratados e dispostos em locais legalmente apropriados. Na maioria dos municípios brasileiros, estes lodos são despejados sem nenhuma forma de tratamento, contribuindo com a degradação da qualidade dos mananciais. O lodo é constituído de materiais inorgânicos como siltes e sílicas, matéria orgânica degradável, com presença de microorganismos patógenos e metais, oriundos do próprio manancial de captação ou do coagulante utilizado durante o processo de coagulação. O objetivo principal deste trabalho foi verificar a possibilidade da utilização dos lodos das ETA como Fonte Alternativa de Energia, comparando os lodos gerados com Sulfato de Alumínio (SA), Polialumínio Cloreto (PAC) e Tanino (T) extraído de casca de Acacia mearsii de Wild. A metodologia utilizada contou com as seguintes análises físicas e químicas: Estereomicroscopia, Microscopia Eletrônica de Varredura (MEV), Difração de Raio X (DRX), Perda ao Fogo (PF) e Poder Calorífico Superior (PCS) e Inferior (PCI). Valores simulados de economia com a utilização dos lodos como fonte alternativa também foram levados em consideração. Os lodos ao SA e ao PAC foram coletados diretamente na planta da ETA São Gabriel Saneamento, localizada no Município de São Gabriel/RS e, o lodo ao Tanino foi gerado no Laboratório de Recursos Hídricos e Saneamento Ambiental, na Universidade Federal do Pampa, campus São Gabriel. Os resultados apontaram que o lodo ao tanino apresentou uma quantidade maior de matéria orgânica, com perda ao fogo de 40,5%, maior teor de carbono (15%), hidrogênio de 2,44% e um poder calorífico de 4.347,30kJ.kg-1, podendo ser utilizado como biossólido, na reconstituição de áreas degradadas e como fonte de energia. Já o lodo ao SA, apresentou uma perda ao fogo de 23,2%, carbono de 5%, hidrogênio de 2,3%, um poder calorífico baixo de 1.384,40 kJ.kg-1, enquanto que o lodo ao PAC apresentou uma perda ao fogo de 30,0%, carbono de 6,41%, hidrogênio de 2,05%, um poder calorífico baixo de 2.746,50kJ.kg-1, ficando entre ao SA e ao Tanino. A diminuição na conta de energia elétrica da estação estudada resultou em 3,22% para lodo ao PAC e 4,67% para lodo ao Tanino, correspondendo a uma economia anual com transporte para descarte e com geração de energia elétrica de US$9.590,44 para o PAC e US$10.615,38 para o Tanino. A fim de potencializar estes resultados foram acrescentadas porcentagens diferentes de casca de arroz (CA), técnica esta chamada de cofiring. Para as misturas obteve-se uma economia de consumo de energia elétrica de 6,32% (PAC+15%CA) e 8,39% (PAC+25%), correspondendo aos valores de US$13.839,77 e US$16.795,41 respectivamente. Os resultados mostraram que lodos de ETA possuem potencial de geração de energia, podendo ser aplicada dentro das próprias instalações de processo tornando-as mais sustentáveis em termos energéticos.<br>Sludge is the main solid waste generated in a Water Treatment Plant (WTP). Non- Hazardous and Non-Inert Solid Waste (Class IIA) by ABNT 10,004/2004 (Brazilian Regulation) is considered as being treated and disposed of in legally appropriate places. In most Brazilian municipalities, these sludges are dumped without any form of treatment, contributing to the degradation of the quality of the springs. The sludge is composed of inorganic materials such as silt and silica, degradable organic matter, with the presence of pathogenic microorganisms and metals, originating from the source of collection or the coagulant used during the coagulation process. The main objective of this work was to verify the possibility of using WTP sludge as an Alternative Energy Source, comparing sludge generated with Aluminum Sulphate (SA), Polyaluminium Chloride (PAC) and Tannin (T) extracted from Acacia mearsii of Wild. The methodology used included the following physical and chemical analyzes: Stereomicroscopy, Scanning Electron Microscopy (SEM), X-ray Diffraction (XRD), Fire Loss (PF) and Upper Calorific Power (PCS) and Inferior (PCI). Simulated values of economy with the use of sludge as an alternative source were also taken into account. The sludge from the SA and PAC was sampled directly from the São Gabriel Saneamento WTP, located in the São Gabriel City (Southern Brazil), and the sludge from Taninn was generated at the Laboratory of Water Resources and Environmental Sanitation at the Universidade Federal do Pampa, Campus São Gabriel. The results showed that the sludge to the tannin presented a higher amount of organic matter, with a loss of 40.5%, a higher carbon content (15%), a hydrogen of 2.44% and a calorific value of 4 347.30 kJ. kg-1, which can be used as biosolids, in the reconstitution of degraded areas and as an energy source. The sludge to aluminum sulphate (SA) presented a fire loss of 23.2%, carbon of 5%, hydrogen of 2.3%, a low calorific value of 1,384.40 kJ.kg-1, while the sludge to Polyaluminium Chloride (PAC) presented a fire loss of 30.0%, carbon of 6.41%, hydrogen of 2.05%, a low calorific value of 2,746.50 kJ.kg-1, being between SA and Tannin. The decrease in the electricity bill of the station studied resulted in 3.22% for sludge to PAC and 4.67% for sludge to Taninn, corresponding to an annual economy with transportation for disposal and with electric power generation of US$9,590.44 for the PAC and US$10,615.38 for Tannin. In order to potentiate these results were added different percentages of rice husk (CA), a technique called cofiring. For the mixtures, electricity consumption was 6.32% (PAC + 15% CA) and 8.39% (PAC + 25%), corresponding to the amounts of US$13,839.77 and US$16,795.41 respectively. Results showed that WTPA sludge has potential for energy generation, and can be applied within the process facilities themselves becoming more sustainable in terms of energy.
APA, Harvard, Vancouver, ISO, and other styles
16

Oliveira, Mariangela Dutra de. "Desenvolvimento de modelos de previsão de desempenho de estações convencionais de tratamento de água." Universidade Federal de Minas Gerais, 2014. http://hdl.handle.net/1843/BUBD-9JHMQW.

Full text
Abstract:
This work consisted in the development of two models using the Fuzzy Logic in order to predict the performance of conventional water treatment plants, based on finished and settled turbidity. The Model for Performance Prediction 1 (MPD1 ) was developed based on indices as tools used in making decisions about the process improvements. Due to the inherent limitations of these indices it was also developed the MPD2, taking into account the most important variables related to the raw water quality and the treatment plant characteristics. Both models were developed based on database of eight plants which average flow rate range from 190 L.s-1 to 5,400 L.s-1. The conventional process was chosen because it is the most common water treatment process in Brazil and the Fuzzy Logic usually permits the insertion of the experts' knowledge in the development of indices and models. In addition, it works with data that doesn't have a linear pattern that would become very difficult the use of classical mathematical models. The difficulty to develop a generic model for predicting the finished turbidity was confirmed mainly due to: the great number of interactions in the water treatment process, the raw water quality, the frequency of monitoring of raw and finished water, and the lowest variability of the plant's finished turbidity for compliance with the drinking water quality standards. It was evidenced that there is low correlation coefficients between the finished turbidity predicted by the models and the finished turbidity observed in database. The MPD2 was viable to estimate the median finished and settled turbidity in spite of the limitations to deal with extreme values. Finally, it is possible to infer with use of the models that the raw water quality seems to be more relevant than the characteristics of the treatment plant in order to comply with more restrictive drinking water quality standards.<br>Este trabalho teve como proposta desenvolver dois modelos de previsão de desempenho de estações convencionais de tratamento de água (ou de ciclo completo), com predição da turbidez da água decantada e tratada utilizando a Lógica Fuzzy. O Modelo de Previsão de Desempenho 1 (MPD1) foi desenvolvido com base em índices, ferramenta utilizada na tomada de decisão sobre melhorias no processo. Devido às limitações inerentes a esses índices também foi desenvolvido o MPD2 levando em consideração as variáveis mais relevantes relacionadas às características da água bruta e da estação de tratamento. Ambos modelos foram desenvolvidos a partir de banco de dados de oito estações com vazão média afluente de 190 L/s a 5400 L/s. A tecnologia convencional de tratamento foi escolhida por ser mais empregada para potabilização da água no Brasil e a Lógica Fuzzy por permitir a inserção do conhecimento de especialistas no desenvolvimento dos índices e modelos e trabalhar com dados que não possuem um padrão linear, o que dificulta a utilização de modelos matemáticos clássicos. Foi possível observar a dificuldade em desenvolver um modelo genérico para predição da turbidez da água tratada, devido às inúmeras interações que ocorrem no tratamento, às características da água bruta, à frequência de monitoramento das mesmas e à menor variabilidade da turbidez efluente da estação devido ao atendimento ao padrão de potabilidade. Para ambos os modelos, verificaram-se baixos coeficientes de correlação entre a turbidez da água tratada estimada e observada nas estações amostradas. O MPD2 mostrou-se viável na estimativa da turbidez mediana da água decantada e tratada, ainda que apresentasse limitações na previsão de valores extremos. Por fim, é possível inferir com esse modelo que a qualidade da água bruta parece ser mais relevante que as características da estação de tratamento no atendimento a padrões de potabilidade mais restritivos.
APA, Harvard, Vancouver, ISO, and other styles
17

Moriya, Nataly Mitie Natsume. "Estudo de viroma em água de esgoto influente e efluente na estação de tratamento de esgoto norte em Brasília." reponame:Repositório Institucional da UnB, 2018. http://repositorio.unb.br/handle/10482/32276.

Full text
Abstract:
Dissertação (mestrado)—Universidade de Brasília, Instituto de Biologia, Pós-Graduação em Biologia Microbiana, 2018.<br>Submitted by Raquel Viana (raquelviana@bce.unb.br) on 2018-07-20T17:33:47Z No. of bitstreams: 1 2018_NatalyMitieNatsumeMoriya.pdf: 2644950 bytes, checksum: ea481d769cf8a761af43566c542d198a (MD5)<br>Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2018-07-20T19:34:41Z (GMT) No. of bitstreams: 1 2018_NatalyMitieNatsumeMoriya.pdf: 2644950 bytes, checksum: ea481d769cf8a761af43566c542d198a (MD5)<br>Made available in DSpace on 2018-07-20T19:34:41Z (GMT). No. of bitstreams: 1 2018_NatalyMitieNatsumeMoriya.pdf: 2644950 bytes, checksum: ea481d769cf8a761af43566c542d198a (MD5) Previous issue date: 2018-07-20<br>Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES).<br>A contaminação por patógenos humanos na água de esgoto é um assunto importante, principalmente em locais onde as condições de saneamento não são ideais. A tecnologia de Next Generation Sequencing (NGS) tem sido utilizada em diversos estudos metagenômicos virais (viromas). Além de descrever a diversidade genética, é uma ferramenta útil para analisar o viroma em amostras de esgoto. Apesar do interesse no tratamento de água, a cidade de Brasília não possuí um estudo de censo e informações focado na contaminação viral do Lago Paranoá. Com este propósito, os patógenos humanos astrovírus (HAstV), norovírus (NoV) e sapovírus (SaV) foram selecionados e investigados em amostras de água não-tratada (influente) e tratada (efluente) utilizando o NGS. Amostras de influente e efluente (de março, maio de 2016 e fevereiro de 2017) foram coletadas na estação de tratamento de água de esgoto em Brasília, Brasil. As amostras foram submetidas a processos de extração de RNA e as bibliotecas de cDNA foram sequenciadas através do Illumina HiSeq 2000, com a condição de 100 bases paired-end. Os reads foram trimados através do Trimmomatic e os contigs foram montados com os programas Megahit e Velvet. As sequências foram analisadas por tBLASTX e Megablast, respectivamente, contra o "RefSeq Virus" utilizando o software Geneious v.8.1. Os reads resultantes também foram enviados e analisados na plataforma online Kaiju. Os SaV foram detectados nas seis amostras sequenciadas, HAstV e NoV foram encontrados em todas as amostras, exceto no efluente de maio. Os resultados encontrados foram discutidos e comparados com estudos brasileiros e internacionais.<br>Contamination of human pathogen in wastewater is an important matter, especially where sanitation is not ideal condition. Next Generation Sequencing (NGS) has been applied in several viral metagenomes (viromes) studies. Besides describing gene diversity, it is a helpful tool to analyze virome in sewage water. Despite the interest in wastewater treatment, Brasilia city lacks a census study and information aiming to assess viral contamination in Paranoa lake. For this purpose, the human pathogens astrovirus (HAstV), norovirus (NoV) and sapovirus (SaV) were selected in untreated (influent) and treated (effluent) wastewater and investigated using NGS technology. Samples of influent and effluent stream (from March, May of 2016 and February of 2017) were collected at the treatment station of wastewater in Brasília, Brazil. Samples were submitted to RNA extraction process and the cDNA libraries were sequenced using Illumina HiSeq 2000 with the condition of 100 base paired-end. The NGS reads were trimmed by Trimmomatic and the contigs were assembled with Megahit and Velvet. The assembled contigs were analyzed by tBLASTX and Megablast, respectively, against RefSeq Virus using Geneious Software v.8.1. Resulted reads were also uploaded and analyzed on Kaiju online platform. SaV were detected in the six sequenced samples, HAstV and NoV were found in all samples except the May untreated water sample. The results found were discussed and compared with Brazilian and international studies.
APA, Harvard, Vancouver, ISO, and other styles
18

Leão, Vonivaldo Gonçalves. "Água tratada : formação de trialometanos pelo uso do cloro e os riscos potenciais à saúde pública em cidades da mesorregião do leste rondoniense." reponame:Repositório Institucional da UnB, 2008. http://repositorio.unb.br/handle/10482/3636.

Full text
Abstract:
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, 2008.<br>Submitted by Fernanda Weschenfelder (nandaweschenfelder@gmail.com) on 2009-10-01T16:37:34Z No. of bitstreams: 1 2008_VonivaldoGoncalvesLeao.pdf: 1155017 bytes, checksum: 1b88ff500969bbffafe217ae8a09a07a (MD5)<br>Approved for entry into archive by Marília Freitas(marilia@bce.unb.br) on 2010-02-12T22:44:01Z (GMT) No. of bitstreams: 1 2008_VonivaldoGoncalvesLeao.pdf: 1155017 bytes, checksum: 1b88ff500969bbffafe217ae8a09a07a (MD5)<br>Made available in DSpace on 2010-02-12T22:44:01Z (GMT). No. of bitstreams: 1 2008_VonivaldoGoncalvesLeao.pdf: 1155017 bytes, checksum: 1b88ff500969bbffafe217ae8a09a07a (MD5) Previous issue date: 2008<br>Nos sistemas de abastecimento de água potável é comum o uso do cloro e de seus derivados. O poder de oxidação do cloro livre sobre bactérias reduz e protege a água contra as proliferações de microorganismos. A mesorregião leste do estado de Rondônia, composta pelos municípios Cacoal, Ji-Paraná, Espigão d’Oeste, Pimenta Bueno, Rolim de Moura, Alta Floresta d’Oeste, Ministro Andreazza e Presidente Médici que fizeram parte do estudo desta dissertação, é caracterizada pela presença de rios que servem como captação de água a ser tratada e fornecida à população. Devido a vários estudos realizados com relação à presença de contaminantes químicos formados após a cloração da água, principalmente a formação de trialometanos, estudos estes que procuram correlacionar a possibilidade destes compostos serem carcinogênicos e mutagênicos, neste trabalho foram analisados os níveis de trialometanos formados nas estações de tratamento de água. As amostras foram coletadas em épocas sazonais e os resultados demonstraram a existência de pontos críticos quanto à formação de trialometanos, dentre eles alguns possíveis motivos são: em Ji-Paraná a água bruta contendo contaminação de trialometanos, principalmente diclorometano, e também a disposição dos equipamentos, provocando um maior contato do cloro livre com substâncias orgânicas. Em Alta Floresta d’Oeste a precariedade nos decantadores e filtros que não condiz com a vazão de tratamento. De acordo com este estudo em épocas chuvosas há diminuição dos níveis de trialometanos, diferentes dos apresentados em estudos em outras localidades. Há a possibilidade das características do solo na região de estudo influenciar e fazer com que haja diluição do leito conforme dados físicoquímicos apresentados. Também não é descartado o alto índice de partículas sólidas, produtos de combustão de matas na região durante o período de estiagem. A absorção de substâncias particuladas pode influenciar nos níveis de formação de subprodutos de cloração, além do alto índice de CO2 presente na atmosfera. Nas demais estações de tratamento de água, há formação de trialometanos, mas nos níveis abaixo dos especificados pela Portaria 518/2004 do Ministério da Saúde. Não há relato de estudos realizados quanto aos níveis de trialometanos nas águas de abastecimento público no Estado de Rondônia. É importante um acompanhamento periódico quanto à formação dos produtos e um estudo mais aprofundado de adequação de tempo de exposição com cloro livre para minimizar ainda mais os níveis formados de trialometanos. Importante também um monitoramento nas águas dos rios que já possuem formação ou apresentam uma certa quantidade de trialometanos, que podem ser resíduos industriais. A saúde pública é uma prioridade e a água contendo trialometanos pode estar correlacionada com doenças carcinogênicas e mutagênicas. ________________________________________________________________________________________ ABSTRACT<br>In the water supplies of drinking water is the common use of chlorine and its derivatives. The powers of oxidation of free chlorine on reducing bacteria and protect the water against the proliferations of microorganisms. The mesoregion eastern state of Rondonia, made by municipalities Cacoal, Ji-Parana, Espigão d'Oeste, Pimenta Bueno, Rolim de Moura, Alta Floresta d'Oeste, Ministro Andreazza and Presidente Medici that were part of the study of this dissertation, is characterized by the presence of rivers that serve as abstraction of water to be treated and supplied to the population. Due to various studies with respect to the presence of chemical contaminants formed after the chlorination of water, mainly the formation of trihalomethanes, these studies seeking to correlate the possibility of these compounds are carcinogenic and mutagenic, in this study were analyzed the levels of trihalomethanes formed at stations water treatment plants. The samples were collected in times seasonal and the results demonstrated the existence of hot spots on the formation of trihalomethanes, including some possible reasons are: Ji-Parana in the contamination of raw water containing trihalomethanes, especially dichloromethane, and also the provision of equipment, causing a greater contact of free chlorine with organic substances. In Alta Floresta d'Oeste in the precarious decanters and filters that is not compliant with the flow of treatment. According to this study in rainy seasons are decreased levels of trihalomethanes, different from those presented in studies in other locations. There is the possibility of soil characteristics in the region of study and influence to make dilution of the bed as physical-chemical data submitted. It is not discarded the high rate of solid particles, products of burning of forests in the region during the drought. The absorption of particulate substances can influence the levels of training for byproducts of chlorination, in addition to this high rate of CO2 in the atmosphere. In other water treatment plants, there is formation of trihalomethanes, but at levels below those specified by the Ordinance 518/2004 of the Ministério da Saúse. There is no report of studies about the levels of trihalomethanes in public water supply in the state of Rondônia. It is important periodic monitoring on the training of products and further study of adequacy of time of exposure with free chlorine to minimize further the levels of trihalomethanes formed. Important also a tracking in the waters of rivers that already have training or have a certain amount of trihalomethanes, which can be industrial waste. Public health is a priority and water containing trihalomethanes can be correlated with disease carcinogenic and mutagenic.
APA, Harvard, Vancouver, ISO, and other styles
19

Jacomassi, Fabio Evandro. "Estudo das micropropriedades de resíduos sólidos gerados nos decantadores de estações de tratamento de água." Universidade Federal de São Carlos, 2009. https://repositorio.ufscar.br/handle/ufscar/4281.

Full text
Abstract:
Made available in DSpace on 2016-06-02T20:00:32Z (GMT). No. of bitstreams: 1 2799.pdf: 10407408 bytes, checksum: 69f85421eb6843f50163b11fb36900ef (MD5) Previous issue date: 2009-10-27<br>The conventional or life-cycle system for water treatment (chemical coagulation, flocculation, sedimentation, filtration, disinfection, fluoridation and pH correction) employed in most water treatment plants (WTP) in Brazil turns water unfit for human consumption (spring water and surface water) into a product that is in accordance with the drinking water guidelines for distribution to the population. In this system, the waste generated in the decanters by the addition of chemical coagulants has been termed WTP sludge . This material consists of solid phase and liquid phase (this latter divided into distinct fractions), and free water may represent a considerable portion of it, depending on the cleaning of the sedimentation tanks. The natural removal of free water from WTPs can be performed by natural systems to reduce volume, in which task the drainage beds play a key role. This work studied the microcomponents of solid waste generated in the WTP decanters of 03 cities in the state of Sao Paulo which use distinct types of chemical coagulants. The samples passed through a drying process and subsequent laboratory analysis. In light of the results, suitable strategies for either disposal or reuse of the waste were considered. It was concluded that sludge from sources 1 and 3 have potential for reuse in ceramics, because they have high contents of Al and Si. On the other hand, sludge 2 may be used in red ceramics (due to the high percentage of Iron).<br>O sistema de tratamento de água convencional ou de ciclo completo (coagulação química, floculação, decantação, filtração, desinfecção, fluoretação e correção de pH) utilizado na maioria das Estações de Tratamento de Água (ETAs) do Brasil, transforma água inadequada para o consumo humano (água bruta de mananciais superficiais) em um produto que esteja em acordo com o padrão de potabilidade para distribuição à população. Neste sistema, gera- se resíduos nos decantadores (através da adição de coagulante químico), que denomina- se de lodo de ETA . Este material é constituído de fase sólida e fase líquida (a fase líquida subdividida em diferentes frações), e a água livre pode representar quantidade apreciável, dependendo da forma de limpeza dos decantadores. A remoção natural de água livre dos resíduos de ETAs pode ser realizada por sistemas naturais de redução de volume, destacando- se neste sentido os leitos de drenagem. O presente trabalho estudou as micropartículas constituintes dos resíduos sólidos gerados nos decantadores das ETAs de 03 cidades do interior do estado de São Paulo (que utilizam diferentes tipos de coagulantes químicos), sendo que este resíduo passou pelo processo de secagem, com a realização posterior de análises laboratoriais, avaliação dos resultados obtidos e avaliação no sentido de analisar uma forma de disposição final (ou reaproveitamento) adequado para este material. Concluiu- se que os lodos 1 e 3 possuem potencial de reutilização em produtos cerâmicos, pois possuem altos teores de Al e Si. Já o lodo 2, poderá ser utilizado em cerâmica vermelha (devido ao elevado percentual de Ferro).
APA, Harvard, Vancouver, ISO, and other styles
20

ALBUQUERQUE, Adriana Muniz de Almeida. "Avaliação de metais e radionuclídeos em amostras de água e lodo de estações de tratamento de água da região metropolitana do Recife." Universidade Federal de Pernambuco, 2013. https://repositorio.ufpe.br/handle/123456789/10106.

Full text
Abstract:
Submitted by Amanda Silva (amanda.osilva2@ufpe.br) on 2015-03-03T12:57:46Z No. of bitstreams: 2 Dissertação Adriana Muniz de Almeida Albuquerque.pdf: 1808962 bytes, checksum: 9965a609f75e8133af3c9560c3bc8e00 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)<br>Made available in DSpace on 2015-03-03T12:57:46Z (GMT). No. of bitstreams: 2 Dissertação Adriana Muniz de Almeida Albuquerque.pdf: 1808962 bytes, checksum: 9965a609f75e8133af3c9560c3bc8e00 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2013<br>Os metais e radionuclídeos estão naturalmente incorporados aos corpos d’água. Estes elementos podem chegar a população configurando um risco potencial a saúde pública. Em virtude disto a concentração destes elementos é um dos critérios inseridos no padrão de potabilidade. Os mananciais que apresentam a volume necessário para o abastecimento da população, contudo, não possuem a qualidade requerida, sendo por tanto necessária a utilização de tecnologias de tratamento que possam remover tais impurezas. Os tratamentos aplicados retêm nas etapas do processo os materiais incorporados as águas e em consequência é gerado um resíduo comumente denominado lodo. Este resíduo pode apesentar concentrações apreciáveis de metais e radionuclídeos, e é classificado como um resíduo sólido pela Associação Brasileira de Normas Técnicas – ABNT e como um Material Radioativo de Ocorrência Natural Concentrado Tecnologicamente (TENORM) pela United States Enviromental Protection Agency – USEPA. Foi realizado assim a analise da concentração dos metais Zn, Mn, Cd, Cu, Cr, e Pb e dos radionuclídeos 226Ra, 228Ra e 40K em amostras de água e lodo de duas Estações de tratamento de águas – ETA’s distintas da Região Metropolitana do Recife. A partir dos resultados obtidos foi possível inferir que as águas tratadas nas ETA’s analisadas estão em concordância com os valores estabelecidos na legislação vigente, para os metais Zn, Mn, Cd, Cu, Cr, Pb e para os radionuclídeos 226Ra e 228Ra. Por outro lado, as concentrações de Fe e Al nas amostras de água pronta para o consumo em uma das ETA estão acima do estabelecido, estando esta inadequação possivelmente relacionada à falha no floculador. A concentração dos metais Zn, Mn, Cd, Cu, Cr, Pb e Fe no lodo foram superiores aos valores observados na literatura, estando inclusive as concentrações de Pb e Zn superiores ao estabelecido no padrão de lançamento de efluentes da resolução nº430/11 do Conselho Nacional do Meio Ambiente - CONAMA o que intensifica a necessidade do tratamento dos resíduos das ETA’s avaliadas, antes do inicio de qualquer processo de descarga no ambiente. Quanto aos valores obtidos para a concentração de atividade dos radionuclídeos 226Ra, 228Ra e 40K, os valores obtidos estão similares ao observado na literatura. O presente estudo possibilitou assim a obtenção de informações relacionadas à presença e comportamento de metais e radionuclídeos de águas e lodo de ETA’s da Região Metropolitana do Recife.
APA, Harvard, Vancouver, ISO, and other styles
21

Olinger, Cristiano. "Caracterização e clarificação por sedimentação da água de lavagem de filtro rápido de uma estação de água." Florianópolis, SC, 2002. http://repositorio.ufsc.br/xmlui/handle/123456789/83820.

Full text
Abstract:
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Ambiental.<br>Made available in DSpace on 2012-10-20T03:42:01Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-26T01:09:09Z : No. of bitstreams: 1 193973.pdf: 14011055 bytes, checksum: 494fe92048f0a8b85d532725557a7056 (MD5)<br>Atualmente, as estações de tratamento de água, tem utilizado em sua maioria, os corpos receptores mais próximos ou a rede de águas pluviais como destino final para os resíduos formados durante o processo de tratamento A maior parcela destes resíduos é formada pela água proveniente da lavagem dos filtros e pode chegar, dependendo da ETA, de 1 a 5 % do volume total de água tratada. A diminuição destes resíduos formados e disposição final adequada deve ser estudada para que se possibilite a adoção destes métodos por todas as ETAs. O reaproveitamento da água de lavagem dos filtros, após sua clarificação, é importante pois contribui para o atendimento da crescente demanda de água e a diminuição do despejo, que será tratado e/ou enviado para a disposição final. Neste trabalho foi estudada a caracterização da água de lavagem dos filtros de uma ETA que utiliza sulfato de alumínio como coagulante primário. Através desses ensaios verficam-se a possibilidade de reaproveitamento da água de lavagem dos filtros, mediante a recirculação de parte desta água que possui após algum tempo qualidade superior a água aduzida a ETA e também a viabilidade de clarificação por sedimentação da água de lavagem.
APA, Harvard, Vancouver, ISO, and other styles
22

Casimiro, Cláudio José da Silva. "Auditorias energéticas a estações de tratamento de águas residuais." Master's thesis, Universidade de Évora, 2013. http://hdl.handle.net/10174/14973.

Full text
Abstract:
O presente trabalho tem como objetivo efetuar uma caracterização da experiência profissional do candidato Cláudio José da Silva Casimiro, à obtenção do grau de Mestre em Energia e Ambiente. Para tal, é efetuado um desenvolvimento de um tema para discussão que se prende com a realização de auditorias energéticas a estações de tratamento de águas residuais. No desenvolvimento do tema é efetuada uma revisão bibliográfica sobre a articulação da execução de auditorias energéticas com os domínios da energia e do ambiente. Nesta revisão são enfatizados os temas relacionados com a dependência, diversificação e intensidade energética. É também analisado o enquadramento legal e metodológico das auditorias energéticas e a sua fundamentação como uma ferramenta para a dinamização da eficiência energética. Em seguida é realizada uma descrição de um caso de estudo. Este caso de estudo apresenta a execução de quatro auditorias energéticas realizadas pelo candidato a estações de tratamento de águas residuais. É efetuada uma descrição dos processos associados ao tratamento de águas residuais, dando especial atenção à vertente energética dos mesmos e à explicitação da metodologia aplicada na execução das auditorias. É também realizada uma análise da contabilidade energética das instalações auditadas, dando especial relevo aos indicadores de eficiência energética (consumo de energia especifico, intensidade energética e intensidade carbónica). Por fim é efetuado uma descrição, fundamentada com cálculos, das oportunidades de racionalização dos consumos detetadas na realização das auditorias energéticas. No final do relatório é apresentada uma descrição detalhada do percurso profissional do candidato, acentuando exaustivamente a experiência e atividade profissional no domínio da energia e do ambiente, bem como a listagem de artigos publicados e outras competências adquiridas; ABSTRACT: The present report aims to describe the professional experience of the candidate Cláudio José da Silva Casimiro to obtain the degree of Master in Energy and Environment. To achieve this goal a development of a theme is done. The theme that is addressed relates the conduction of energy audits for wastewater treatment plants. The development of the theme will be carried out by a literature review that stresses the relation of the energy audits with energy and the environment. In this review will be also emphasized issues related with energy dependence, energy diversification and energy intensity. It will be also examined the legal framework and methodology of energy auditing and its importance as a tool for boosting energy efficiency. Afterwards, a description of a case study will be made. This case study presents the implementation of four energy audits conducted by the candidate for wastewater treatment plants. It will be made a description of the processes associated with wastewater treatment, giving particular focus on the energy issues and the methodological framework applied for conduction of the audits. It is also analyzed the energy accounting of the plants, with particular emphasis on energy efficiency indicators (specific energy consumption, energy intensity and carbon intensity). Finally a description of the energy efficiency opportunities that was detected at the energy audits will be made. At the end of the report is focused a detailed description of the candidate's career, highlighting the professional experience on the energy and the environment, as well as a listing of published articles and other skills acquired.
APA, Harvard, Vancouver, ISO, and other styles
23

Chao, Iara Regina Soares. "Remoção de fósforo de efluentes de estações de tratamento biológico de esgotos utlizando lodo de estação de tratamento de água." Universidade de São Paulo, 2006. http://www.teses.usp.br/teses/disponiveis/3/3147/tde-14122006-145950/.

Full text
Abstract:
O fósforo é apontado como o principal responsável pelo enriquecimento nutricional de mananciais de abastecimento público, desencadeando por meio do fenômeno de eutrofização, a floração de grupos algais tóxicos e, portanto a sua remoção passa a ter grande significado para a saúde pública e para o meio ambiente. O presente trabalho foi desenvolvido com os objetivos de: avaliar a eficiência de remoção de fósforo do efluente de um sistema convencional de lodos ativados (Estação de Tratamento de Esgotos de Barueri) pelo lodo de uma estação de tratamento de água, que utiliza sulfato de alumínio como coagulante (Estação de Tratamento de Água do Alto Cotia) e verificar a influência das seguintes variáveis nesta remoção: tempo de permanência do lodo no decantador, dosagem de lodo, potencial zeta, teor de matéria orgânica no lodo, pH da mistura lodo/efluente e uso de polímero na coagulação/floculação da água bruta. Para o desenvolvimento prático da pesquisa, foram realizados ensaios de jarros, variando as condições operacionais, de tal forma a averiguar o efeito das variáveis mencionadas anteriormente na remoção do fósforo. Observou-se que esta remoção era dependente do pH; da dosagem de lodo; do tempo de permanência do mesmo no decantador; do tempo de mistura e da presença de polímero. Independia do potencial zeta e do tempo de sedimentação. A máxima remoção obtida foi de 100% (concentração inicial de 2,9 mg P/L), em pH de 4,5, com dosagem de 37 mg lodo/L, tempo de mistura de 15 minutos a 40 s-1 de gradiente, tempo de sedimentação de 30 minutos, tempo de permanência do lodo no decantador de 80 dias, sem polímero. Nestas condições, a concentração de fósforo do efluente tratado foi de 0,01mg P/L. Os resultados obtidos no presente trabalho sinalizam uma alternativa tecnológica, que pode vir a ser utilizada em projetos sustentáveis, em que as estações de tratamento de esgotos e estações de tratamento de água sejam planejadas de forma integrada, considerando o reaproveitamento e encaminhamento do lodo de ETA como insumo a ser utilizado no fim do processo de tratamento de esgotos para remoção de fósforo do efluente final, em consonância com os conceitos de produção mais limpa na busca da qualidade.<br>Phosphorus is considered as the main responsible for the nutritional enrichment of reservoirs of public drinking water supplies, because eutrophication process has resulted in toxic algae blooms, and therefore its removal has a great significance since these toxins represent a public health risk and environment. The aim of this research work was to evaluate the efficiency of removal of phosphate from activated sludge process (Barueri Wastewater Treatment Plant) by sludge from water treatment plant that uses aluminum sulfate as coagulant (WTP Alto Cotia) and verify the influence of following operational parameters in this removal: aging of sludge, sludge dose, zeta potential, mixing time, sedimentation time, concentration of organic matter, pH and use of polymer in coagulation/flocculation process. For the experimental research, the jar tests were operated with different conditions. The removal of phosphate was dependent of pH, sludge dose, aging of sludge, mixing time and presence of polymer. It was independent of zeta potential and sedimentation time. It was verified that maximum efficiency of phosphate removal was around 100% (initial concentration = 2,9 mgP/L), in pH 4,5 with the use of 37 mg of sludge from Alto Cotia Water Treatment Plant per liter of effluent from Barueri Wastewater Treatment Plant, with a mixing time of 15 minutes at 40 s-1, 30 minutes for sedimentation time, 80 days for aging of sludge, without polymer. Under these conditions it was obtained phosphate concentrations around 0,01mgP/L. Results obtained in this research work show a technological alternative, that can be used in projects, that sewage and water treatment plants can be planned together, considering the reuse and forwarding the water treatment plant sludge as beneficial use in the end of the sewage treatment process for the phosphorus removal, in consonance with concepts of a cleaner production practices in Environmental Management Systems.
APA, Harvard, Vancouver, ISO, and other styles
24

MONTEIRO, Natali Barbosa. "Características de lodos de estações de tratamento de água desidratados por sistema geotêxtil: estudo de caso." UNIVERSIDADE FEDERAL DE PERNAMBUCO, 2014. https://repositorio.ufpe.br/handle/123456789/14983.

Full text
Abstract:
Submitted by Isaac Francisco de Souza Dias (isaac.souzadias@ufpe.br) on 2016-01-25T16:06:28Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) disserta natali. FINAL.pdf: 2684085 bytes, checksum: 8a4ca200d8713256adc6a25a36f5010c (MD5)<br>Made available in DSpace on 2016-01-25T16:06:28Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) disserta natali. FINAL.pdf: 2684085 bytes, checksum: 8a4ca200d8713256adc6a25a36f5010c (MD5) Previous issue date: 2014-08-29<br>CNPq<br>Segundo a legislação brasileira (ABNT-NBR 10.004, 2004) define-se como resíduos sólidos os resíduos nos estados sólidos e semi-sólidos, que em função de sua periculosidade podem ser classificados em duas classes principais: Resíduos Classe I – Perigosos, Resíduos Classe II - Não Perigosos, esse subdividido em duas classes: Resíduos Classe II A - Não Inertes e Resíduos Classe II B - Inertes. Nesse contexto, inserimos o lodo gerado em Estação de Tratamento de Água - ETA, em problema comum da indústria do saneamento no Brasil, onde grande parte desse lodo, ainda se encontra sem o adequado tratamento e destino final, agravado pelo o estado semi-sólido, fator complicador para o transporte e disposição final. Para reduzir o volume de água do lodo existem tecnologias com o uso de adensador, filtro-prensa, centrífuga, secagem térmica e os tubos (bag) de geotêxtil, confeccionados em tecido de polipropileno de alta densidade e resistência, que podem promover uma redução superior à 90% da umidade do lodo. Neste estudo foi avaliado o lodo gerado na ETA Botafogo, localizada na região metropolitana de Recife – PE e gerenciada pela Companhia Pernambucana de Saneamento (COMPESA). O lodo coletado no decantador foi acondicionado em bags, com e sem condicionamento de polímero, por um período de 3 meses. Foram realizadas análises de caracterização antes, durante e depois dos lodos presentes nos bags, além do líquido drenado. Após o completo preenchimento dos bags, realizou-se a metodologia de quarteamento para retirada de amostras de lodo que foram submetidas às análises para avaliação do teor de umidade (%) e dos metais Fe, Cu, Pb, Zn, Mn e Al. Dentre os metais presentes, o alumínio foi escolhido como objeto de estudo, devido o Sulfato de alumínio ser utilizado como coagulante na ETA em questão. Neste sentido, o uso do bag de geotêxtil para concentrar poluentes, que são lançados no solo ou nos recursos hídricos, se mostrou bastante eficiente, visto que o monitoramento da concentração de metais no lodo afluente, do lodo concentrado e do líquido drenado do bag mostrou que 99% do Fe, 98% do Cu, 99% do Pb, 47% do Mn, 100% do Zn e 100% do Al, ficaram retidos no lodo que recebeu a adição do polímero. Quando o lodo não recebeu o condicionamento com polímero, a retenção foi de 98%, 98%, 95%, 55%, 100% e 98% dos respectivos metais. Assim é possível desidratar e concentrar poluentes do lodo com o uso do geotêxtil, condicionado ou não com polímero, para posterior tratamento, reuso ou disposição final no meio ambiente de forma planejada e adequada. Em relação à DQO do permeado, foi observado que para o sistema sem polímero se comportou como o sistema com polímero a partir da segunda coleta.<br>According to Brazilian legislation (ABNT-NBR 10004, 2004) is defined as solid waste residues in solid and semi-solid states, which due to its danger can be classified into two main classes: Class I Waste - Hazardous, Waste Class II - Non Hazardous, this subdivided into two classes: Class II Waste - Waste Not Aggregates and Class IIB - Aggregates. In this context, we entered the sludge generated at the Water Treatment Plant - WTA, a common problem of sanitation industry in Brazil, where much of this type of sludge is still without proper treatment and disposal, aggravated by the state semi -solid complicating factor for transport and final disposal. To reduce the water volume of the sludge technologies exist with the use of filler, filter press, centrifuge, drying and heat pipes (bag) of geotextile made of polypropylene and high-density tissue strength, which can promote a greater reduction to 90% moisture sludge. In this study we evaluated the sludge generated at the WTP Botafogo, located in the metropolitan region of Recife - PE and managed by Pernambuco Sanitation Company (COMPESA). The sludge collected in the decanter was packed in bags with and without conditioning polymer, for a period of 3 months. Characterization analyzes were conducted before, during and after the sludge present in the bags in addition to the drained liquid. After complete filling of the bags, there was the quartering methodology for removal of sludge samples that were subjected to analyze for assessing the moisture content (%) and metals Fe, Cu, Pb, Zn, Mn and Al Among the metal content, aluminum was chosen as the object of study because aluminum sulfate is used as the coagulant WTA studied. In this sense, the use of geotextile bag to concentrate pollutants that are released into the soil or water resources, was very efficient, since the monitoring of the concentration of metals in the influent sludge, the concentrated sludge and liquid drained from the bag showed 99% Fe, 98% Cu 99% Pb, 47% of Mn, and Zn 100% 100% Al, were retained in the sludge which received the addition of the polymer. And when it has received sludge conditioning polymer, retention was 98%, 98%, 95%, 55%, 100% and 98% of the respective metals. Thus it is possible to dehydrate and concentrate pollutants from sludge using geotextile, conditioning or not polymer, for further treatment, reuse or disposal into the environment in a planned and appropriate.
APA, Harvard, Vancouver, ISO, and other styles
25

Guerra, Ricardo Consigliero [UNESP]. "Caracterização e biodegradação de lodo de estações de tratamento de água para descarte em aterro sanitário." Universidade Estadual Paulista (UNESP), 2005. http://hdl.handle.net/11449/94985.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:27:24Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-03-04Bitstream added on 2014-06-13T19:56:03Z : No. of bitstreams: 1 guerra_rc_me_rcla.pdf: 1549626 bytes, checksum: 4e3fd056683f5fd634d2a65641a4f8ae (MD5)<br>Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)<br>A geração e disposição final de resíduos vem se tornando uma preocupação constante em vista dos efeitos negativos proporcionados ao meio ambiente quando estes são dispostos de maneira inadequada. A produção de água para abastecimento público, realizada pelas Estações de Tratamento de Água (ETAs) é responsável pela geração de resíduos, originados pela remoção das partículas em suspensão na água bruta, mediante processos de decantação e filtração. Geralmente, o destino do lodo acumulado nos decantadores é o curso d água mais próximo, sem que nenhum tratamento seja realizado. O objetivo deste trabalho foi verificar a viabilidade da disposição final, em aterro sanitário, dos sólidos resultantes dos processos de secagem do lodo de duas ETAs: ETA Capim Fino, município de Piracicaba, SP e ETA II, município de Rio Claro, SP Os ensaios para a classificação do lodo de ETA foram realizados de acordo com a norma NBR 10.004. Resíduos Sólidos - Classificação (ABNT, 2004a). Os ensaios de biodegradação foram realizados pelo método respirométrico de Bartha (CETESB, 1990), a fim de verificar a influencia da aplicação de diferentes proporções de mistura do lodo de ETA com o solo do aterro sanitário do município de Rio Claro. Os resultados indicam que os lodos estudados, são classificados como resíduos não inertes, necessitando de condições adequadas para sua disposição final, entretanto a aplicação de lodo ao solo do aterro sanitário, não interferiu de forma negativa no processo de biodegradação, indicando que sob esse aspecto, a co-disposição dos sólidos resultantes do processo de secagem dos lodos estudados, juntamente com o solo utilizado na cobertura das células do aterro sanitário do município de Rio Claro, é viável.<br>The production and ultimate disposal of wastes has become a major concern, related to the negative effects over the environment when its disposal occurs in inappropriate ways. Drinking water production by Water Treatment Plants (WTPs) removes from raw water suspended particles by sedimentation and filtration processes, resulting in waste production. In most cases the destination of the accumulated sludge at the sedimentation basins is the nearest water stream. The objective of this study was to verify the viability of ultimate disposal, at a sanitary landfill, of dewatered sludge from two WTPs: WTP Capim Fino, at Piracicaba, SP and WTP II, at Rio Claro, SP The WTP sludge classification tests wore performed according to the norm NBR 10.004 Solid Wastes - Classification (ABNT 2004a). The biodegradation tests wore performed though Bartha's respirometric method (CETESB, 1990), intending to verify the influence of different mixture proportions of WTP sludge and sanitary landfill soil. The results indicate that these wastes are classified as not inert, demanding adequate conditions to its ultimate disposal, however the sludge and sanitary landfill soil mixture did not interfered negatively at the biodegradation process, indicating that the solids resulting from WTP sludge dewatering can be disposed at Rio Claro sanitary landfill.
APA, Harvard, Vancouver, ISO, and other styles
26

Guerra, Ricardo Consigliero. "Caracterização e biodegradação de lodo de estações de tratamento de água para descarte em aterro sanitário /." Rio Claro : [s.n.], 2005. http://hdl.handle.net/11449/94985.

Full text
Abstract:
Resumo: A geração e disposição final de resíduos vem se tornando uma preocupação constante em vista dos efeitos negativos proporcionados ao meio ambiente quando estes são dispostos de maneira inadequada. A produção de água para abastecimento público, realizada pelas Estações de Tratamento de Água (ETAs) é responsável pela geração de resíduos, originados pela remoção das partículas em suspensão na água bruta, mediante processos de decantação e filtração. Geralmente, o destino do lodo acumulado nos decantadores é o curso d’água mais próximo, sem que nenhum tratamento seja realizado. O objetivo deste trabalho foi verificar a viabilidade da disposição final, em aterro sanitário, dos sólidos resultantes dos processos de secagem do lodo de duas ETAs: ETA Capim Fino, município de Piracicaba, SP e ETA II, município de Rio Claro, SP Os ensaios para a classificação do lodo de ETA foram realizados de acordo com a norma NBR 10.004. "Resíduos Sólidos - Classificação" (ABNT, 2004a). Os ensaios de biodegradação foram realizados pelo método respirométrico de Bartha (CETESB, 1990), a fim de verificar a influencia da aplicação de diferentes proporções de mistura do lodo de ETA com o solo do aterro sanitário do município de Rio Claro. Os resultados indicam que os lodos estudados, são classificados como resíduos não inertes, necessitando de condições adequadas para sua disposição final, entretanto a aplicação de lodo ao solo do aterro sanitário, não interferiu de forma negativa no processo de biodegradação, indicando que sob esse aspecto, a co-disposição dos sólidos resultantes do processo de secagem dos lodos estudados, juntamente com o solo utilizado na cobertura das células do aterro sanitário do município de Rio Claro, é viável.<br>Abstract: The production and ultimate disposal of wastes has become a major concern, related to the negative effects over the environment when its disposal occurs in inappropriate ways. Drinking water production by Water Treatment Plants (WTPs) removes from raw water suspended particles by sedimentation and filtration processes, resulting in waste production. In most cases the destination of the accumulated sludge at the sedimentation basins is the nearest water stream. The objective of this study was to verify the viability of ultimate disposal, at a sanitary landfill, of dewatered sludge from two WTPs: WTP Capim Fino, at Piracicaba, SP and WTP II, at Rio Claro, SP The WTP sludge classification tests wore performed according to the norm NBR 10.004 "Solid Wastes - Classification" (ABNT 2004a). The biodegradation tests wore performed though Bartha's respirometric method (CETESB, 1990), intending to verify the influence of different mixture proportions of WTP sludge and sanitary landfill soil. The results indicate that these wastes are classified as not inert, demanding adequate conditions to its ultimate disposal, however the sludge and sanitary landfill soil mixture did not interfered negatively at the biodegradation process, indicating that the solids resulting from WTP sludge dewatering can be disposed at Rio Claro sanitary landfill.<br>Orientador: Dejanira de Franceschi de Angelis<br>Coorientador: Ana Paula de Arruda Geraldes Kataoka<br>Banca: Cassiana M. Reganham Coneglian<br>Banca: Antonia Marli dos Santos<br>Mestre
APA, Harvard, Vancouver, ISO, and other styles
27

Oliveira, Misael Dieimes de. "Desenvolvimento, aplicação e avaliação de sistema de indicadores de desempenho de estações de tratamento de água." Universidade Federal de Minas Gerais, 2014. http://hdl.handle.net/1843/BUOS-9KSFV3.

Full text
Abstract:
The overall objective of this research was to develop, implement and evaluate a system of performance indicators (PI) for water treatment plants (WTP) under the perspective of a regulatory agency. The methodology used consisted of four main steps: (i) survey of PI systems, (ii) selection of elements of PI system, (iii) application of the system developed and (iv) evaluation the proposed system. The survey covered ten major national and international organizations related to research, management and/or regulation, resulting in 423 PI. There was a small proportion of ID specific for WTP (9 %). In water supply systems, the evaluation themes which have most importance were infrastructure (36% of ID) and economy (25%), while for WTP was the theme public health (57%). At first it was proposed a PI system starting from themes, criteria and indicators which selection was based on recommendations presented in literature. The set was discussed with the regulatory agency and the service provider, resulting in a system with three subjects, four criteria and 19 PI, followed by the respective reference values and performance targets. For application of the developed system, monitored water quality data (daily averages) was used, average monthly flows and personnel, chemicals and electric costs of six WTP, with project flow rates between 36 L s-1 and 5.500 L s-1 during the period from 2002 to 2011. By dynamic analysis, it was found that the PI of economy and infrastructure themes showed no significant seasonal variation (Kruskal-Wallis test). On the other hand the PI theme linked to public health proved to be the most impacted by the seasonal variation. Significant trends were observed in 29 of 100 cases analyzed (Mann-Kendall test). The comparative analysis between WTP was performed by cluster analysis the Kruskal-Wallis test followed by multiple comparisons tests. By the end, it was conducted a factor analysis/principal components in order to identify inter-related groups of PI, point out the main PI in each evaluation criterion and investigate the possibility to reduce the number of PI. It is believed that methods employed for selection of system elements, data processing and interpretation of results, as well as discussions about the limits and profile acting, aspects of water treatment and methods of performance measurement, may contribute to the development and improvement of indirect supervision and regulation.<br>O objetivo geral desta pesquisa foi desenvolver, aplicar e avaliar um sistema de indicadores de desempenho (ID) de estações de tratamento de água (ETA) sob a perspectiva de uma agência reguladora. A metodologia empregada constou de quatro etapas principais: (i) levantamento de sistemas de ID, (ii) seleção de elementos constituintes do sistema de ID desenvolvido, (iii) aplicação do sistema desenvolvido e (iv) avaliação do sistema proposto. O levantamento abrangeu dez dos principais órgãos e entidades nacionais e internacionais ligados à pesquisa, gestão e/ou regulação, resultando em 423 ID. Observou-se pequena proporção de ID específicos de ETA (9 %). Em sistemas de abastecimento de água, os temas de avaliação de maior importância foram infraestrutura (36 % dos ID) e economia (25 %), ao passo que para ETA foi o tema saúde pública (57 %). Inicialmente, foi proposto um sistema de ID a partir de temas, critérios e indicadores cuja seleção foi baseada em recomendações expostas na literatura. O conjunto foi discutido com a agência reguladora e com o prestador de serviços e resultou em um sistema com três temas, quatro critérios e 19 ID, acompanhados dos respectivos valores de referência e metas de desempenho. Para aplicação do sistema desenvolvido foram utilizados dados de monitoramento de qualidade da água (médias diárias), vazões médias mensais e custos de pessoal, produtos químicos e energia elétrica de seis ETA, com vazões de projeto entre 36 L s-1 e 5.500 L s-1, no período de 2002 a 2011. Pela análise dinâmica, verificou-se que os ID dos temas economia e infraestrutura não apresentaram variação sazonal significativa (teste Kruskal-Wallis). Já os ID do tema saúde pública mostraram-se os mais impactados com a variação sazonal. Foram verificadas tendências significativas em 29 dos 100 casos avaliados (teste Mann-Kendall). A análise comparativa entre ETA deu-se por meio de análise de agrupamento e teste Kruskal-Wallis seguido de teste de comparações múltiplas. Ao final, foi conduzida uma análise fatorial/componentes principais com a finalidade de identificar grupos inter-relacionados de ID, apontar os principais ID dentro de cada critério de avaliação e investigar a possibilidade de redução do número de ID. Acredita-se que os métodos empregados para seleção dos elementos do sistema, processamento de dados e interpretação de resultados, bem como discussões acerca dos limites e perfil de atuação, aspectos do tratamento de água e métodos de medição de desempenho, possam contribuir para o desenvolvimento e aperfeiçoamento da fiscalização indireta e da regulação.
APA, Harvard, Vancouver, ISO, and other styles
28

Melo, Livia Duarte Ventura. "Aplicação de técnicas estatísticas para avaliação de desempenho e confiabilidade de estações de tratamento de água." Universidade Federal de Minas Gerais, 2014. http://hdl.handle.net/1843/BUOS-9QCH62.

Full text
Abstract:
This paper proposes a methodology for evaluating the performance of treatment plants (WTP), considering unusual statistical tools in the area, applied to six water treatment stations. A characterization of the quality of raw water and treated water in the period 2001-2011, considering the data of turbidity, apparent color, concentrations of residual chlorine and fluoride, pH and total coliforms was performed. Statistical analyzes were performed for the dry and rainy seasons and considered several steps: assessing individual performance of the various treatment plants, considering the standards of potability and quality targets for treated water; comparative study of the performance of various treatment technologies analyzed; comparative analysis of the performance of water treatment plants, according to the size, reliability analysis of treatment plants. On the WTPs performance comparation as a function of technology adopted, the double filtration showed smaller values of turbidity of the treated water than the others process. The color, however, was more efficiently removed by double filtration technology than by the conventional, flotation followed by direct filtration, but it was equivalent to direct filtration process. Parameter for the residual chlorine, it was observed that all treatment technologies are significantly different, both in the dry season and in the rainy season. Performance evaluation of treatment plants grouped by size showed that the WTPs Midsize had the lowest turbidity and color in both periods. The results of the reliability analysis showed that the mean turbidity values observed in the treated water for almost all WTPs would be insufficient to ensure 95% compliance with the standards of 0,3 and 0,5 NTU. As the patterns become more flexible, WTPs can serve them and, in the case of default of 5,0 NTU, all WTPs easily guarantee the percentage of 95 % attendance. All water treatment plants meet the goal imposed by brazilian Ordinance 2914/2011, which defines values less than 15,0 HU for the color parameter.<br>Neste trabalho é proposta uma metodologia de avaliação de desempenho e confiabilidade de estações de tratamento (ETAs), considerando ferramentas estatísticas pouco usuais na área, aplicada a seis estações de tratamento de água. Foi efetuada uma caracterização da qualidade da água bruta e da água tratada no período de 2001 a 2011, considerando os dados de turbidez, cor aparente, concentrações de cloro e de flúor residuais, pH e coliformes totais. As análises estatísticas foram efetuadas para os períodos predominantemente seco e chuvoso e consideraram diversas etapas: avaliação do desempenho individual das diversas estações de tratamento, considerando o atendimento a padrões de potabilidade e metas de qualidade para a água tratada; estudo comparativo do desempenho das diversas tecnologias de tratamento analisadas; análise comparativa do desempenho das ETAs, em função do porte; análise de confiabilidade das estações de tratamento. A comparação de desempenho das ETAs em função da tecnologia de tratamento adotada mostrou que a dupla filtração apresentou valores de turbidez da água tratada menores que os mostrados por todos os outros tratamentos. A cor, no entanto, foi removida de maneira mais eficiente pela tecnologia de dupla filtração, quando comparada com a convencional e flotação seguida de filtração direta, mas de maneira equivalente ao processo de filtração direta. Para o parâmetro residual de cloro, observou-se que todas as tecnologias de tratamento são significativamente diferentes entre si, tanto no período predominantemente seco quanto no período predominantemente chuvoso. A avaliação de desempenho das estações de tratamento agrupadas por porte mostrou que a ETA de médio porte apresentou os menores valores de turbidez e cor em ambos os períodos. Os resultados da análise de confiabilidade mostraram que os valores médios de turbidez observados na água tratada por quase todas as ETAs seriam insuficientes para garantir 95% de atendimento aos padrões de 0,3 e 0,5 uT. À medida que os padrões se tornam mais flexíveis, mais ETAs conseguem atendê-los e, no caso do padrão de 5,0 uT, todas as ETAs garantiriam facilmente o percentual de 95% de atendimento. Todas as estações de tratamento de água atendem a meta imposta pela Portaria 2914/2011, que define valores inferiores a 15,0 uH para o parâmetro cor.
APA, Harvard, Vancouver, ISO, and other styles
29

TAVARES, Rosangela Gomes. "A atenuação do aluminio do resíduo de estações de tratamento de água por vermicompostagem e adsorção." Universidade Federal de Pernambuco, 2016. https://repositorio.ufpe.br/handle/123456789/22325.

Full text
Abstract:
Submitted by Fabio Sobreira Campos da Costa (fabio.sobreira@ufpe.br) on 2017-11-09T14:21:24Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Tese_TeresaLopes_FormacaoDoOlhar.pdf: 34837478 bytes, checksum: 4ed5e247ba7a478bddacd0c98eaef2a5 (MD5)<br>Made available in DSpace on 2017-11-09T14:21:24Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Tese_TeresaLopes_FormacaoDoOlhar.pdf: 34837478 bytes, checksum: 4ed5e247ba7a478bddacd0c98eaef2a5 (MD5) Previous issue date: 2016-12-02<br>CNPQ<br>A produção de água potável exige o adequado tratamento e disposição dos resíduos gerados nas estações de tratamento de água (ETAs), muitas vezes lançados nos corpos hídricos e nos solos. A problemática principal é a presença do alumínio (Al), que limita a disposição direta no meio ambiente. O presente trabalho aborda, em primeiro lugar, a geração, quantificação e disposição de lodos gerados nas ETAs existentes, e em operação no estado de Pernambuco. Em segundo, testaram-se e verificaram-se a viabilidade de tratamento da massa sólida do lodo, através da técnica de vermicompostagem, e, por processo de adsorção, do efluente líquido gerado no deságue do lodo. A pesquisa foi realizada a partir da coleta, sistematização e interpretação de dados secundários, por meio de ensaio de bancada. Os resíduos, provenientes de uma ETA e duas estações de tratamento de esgoto (ETEs), após o deságue, foram misturados, nas proporções: 100/0, 75/25 e 25/75% (ETA/ETE v/v). A vermicompostagem foi realizada com minhocas da espécie Eisenia andrei, por um período de 34 dias. O efluente líquido originado do deságue do lodo, foi tratado por processo de adsorção com o pó das conchas do marisco, Anomalocardia brasiliana, e com o Carvão Ativado (CA). Foram estudados, no tratamento de vermicompostagem, os parâmetros pH, Carbono Orgânico Total (COT), N total, Relação C/N e concentração do Al. No processo adsortivo, os parâmetros foram pH, massa de adsorvente, tempo de contato e concentração do Al. Os resultados mostraram que existem 246 ETAs, em Pernambuco, gerando resíduos, do qual 75% dessas, descartam seus detritos nos corpos hídricos e 22% no solo, sem qualquer tipo de tratamento. Apenas 3% realizam o processo de deságue, porém descartam no solo a massa sólida, sem nenhuma gestão dos mesmos. Por outro lado, o tratamento de vermicompostagem reduziu a massa seca inicial a 19%, aumentou o pH, diminuiu em 50% o teor de COT e aumentou N total de 2 a 5%, reduzindo a relação C/N. Além disso, proporcionou uma redução significativa do teor de Al, em torno de 90%.Tais experiências permitiram concluir que esse resíduo pode ser submetido ao tratamento de vermicompostagem, e as melhores eficiências se obtém quando o mesmo é tratado em conjunto com o lodo de esgoto. Os percentuais de remoção do Al, utilizando o processo de adsorção com o pó das conchas do marisco, nas concentrações de 1,0, 5,0 e 10,0 mg/L, foram de 79, 90 e 92%, nos primeiros 10 minutos de contato, mostrando que o material pode ser uma alternativa viável nos procedimentos de adsorção de metais. Com o CAT, os resultados foram 92% de remoção do Al, com apenas 5 mg/L de material, e após 5 minutos de contato.<br>Brazil presents a growing scenario concerning sanitation, especially for drinkable water production, it requires proper treatment and disposal of waste generated in treatment plants. However, often the waste is disposed into hydrous bodies and soils, where the main problem is addressed to the presence of Al that limits the direct disposal in the environment. The present work aims the evaluation of the quantification and disposal of sludge generated in existing water treatment plants (ETAs) in operation at the state of Pernambuco. The treatment of the solid mass through vermicomposting technique and of the liquid waste generated in the sludge drainpipe, through adsorption process, was studied. The survey was conducted from the collecting, organization and interpretation of secondary data and by bench tests. The wastes from an ETA and two sewage treatment plants (ETEs) that after runoff were mixed in the proportions: 100/0, 75/25 and 25/75% (ETA/ETE v/v). Vermicomposting was performed with earthworm of Eisenia Andrei species over a period of 34 days. The effluent originated from sludge drainpipe was treated by adsorption process with seafood shells powder, Anomalocardia brasiliana, and by Activated Carbon (AC). At the vermicomposting treatment, the following parameters were studied: pH, TOC, total nitrogen, C/N ratio and Al concentration. At the adsorptive process, the parameters were: pH, adsorbent mass, contact time and Al concentration. The results showed that 246 ETAs in Pernambuco generate waste, from which 75% discard their waste in Hydrous bodies and 22% in the ground without any treatment. Only 3% carries out the outflow process, but also the solid mass is disposed on the soil without any waste management. In the other hand, the vermicomposting treatment reduced the initial dry mass to 19%, increased pH, reduced by 50% the TOC content and increased the N total of 2 to 5%, reducing the C /N ratio. The Al content was significantly reduced, to around 90%. Such experience allowed to conclude that this waste can be treated using vermicomposting and the best efficiency is reached when it is treated together with sewage sludge. The percentages of Al removal by adsorption on the powder from shellfish shells, at concentrations of 1.0, 5.0 and 10.0 mg/L, were 79, 90 and 92%, in the first 10 min contact; showing that the material can be a viable alternative to metal adsorption processes. With the AC, 92% of Al removal was obtained with 5 g/L of CAT and after 5 min contact.
APA, Harvard, Vancouver, ISO, and other styles
30

Cosme, Christiano Rebouças. "Avaliação da qualidade da água proveniente de estações de tratamento de água salobra na zona rural do município de Mossoró, RN." Universidade Federal Rural do Semi-Árido, 2011. http://bdtd.ufersa.edu.br:80/tede/handle/tede/483.

Full text
Abstract:
Made available in DSpace on 2016-08-31T13:24:11Z (GMT). No. of bitstreams: 1 ChristianoRC_DISSERT.pdf: 985774 bytes, checksum: 16a5bb519ba17167ab91e67bf421f7f6 (MD5) Previous issue date: 2011-03-30<br>Conselho Nacional de Desenvolvimento Científico e Tecnológico<br>In Brazil, mainly in the semiarid region, a major challenge is to promote the water supply to households in rural areas. Groundwater is identified as a viable alternative to ensure the access of rural communities in the northeast to water from public investment in drilling wells. However, these water sources in most cases have use restrictions for human consumption, because they present problems of salinity. The technology of reverse osmosis has been widely used for treatment of brackish water, with successful experiences in most locations where units have been deployed in water treatment by desalination. Many rural communities in Mossoró, RN, are supplied with water from the aquifer Jandaíra, high salt concentration, which is treated in desalination plants, allowing its use for human consumption. In these communities, the reject brine of the process of desalination is not receiving any treatment or proper disposal, being dumped straight into the ground and, when used in irrigation of crops there are no scientific-technical reasons for their use, causing problems of soil salinization. Due to the impacts caused by the use of brackish or reject brine for irrigation in the soil, to enable their use should always adopt some special practices of water management and soil for salinity control. As the majority of crops grown in the region classified as sensitive to moderately sensitive to salinity, there is the need to better characterize these waters, to establish the appropriate management of plants, soil and irrigation systems. As the majority of crops grown in the region are classified as sensitive to moderately sensitive to salinity, there is the need to better characterize these waters, to establish the appropriate management of plants, soil and irrigation systems. Thus, this study aimed to evaluate the quality of water for irrigation in rural communities of Mossoró, supplied with brackish water from tube wells equipped with desalination, providing this information as a tool to aid the proper management and use of these waters irrigation. 30 rural communities were selected to perform the collection of samples of water from the waste generated in the desalination, purified and in its natural form (brackish water of the well). In the collected samples were determined at electric conductivity (ECw), pH and concentrations of Na+, Ca2+, K+, Cl-, HCO3 - e CO3 2-, in addition, the sodium adsorption ratio (SAR). The Analyses of water samples were interpreted as to risk of salinity, sodicity, toxicity of ions and other quality parameters. The results show that water of the wells rural communities studied, have restrictions to their use in agriculture, as to risks of salinity and sodicity of the soil, especially the waters of the communities: São Romão, Boa Fé and Pau Branco. the reject brine of the desalination have high concentrations of salts, especially in communities of Boa Fé and Puxa Boi, compromising their use for irrigation, and, the desalinated water, although they have low concentrations of salts have restrictions on the problems of infiltration into the soil, if by chance, are employed in irrigation.<br>No Brasil, principalmente na região semiárida, um grande desafio é promover o abastecimento de água às famílias residentes nas áreas rurais. As águas subterrâneas são apontadas como uma alternativa viável para garantir o acesso das comunidades rurais do nordeste à água, a partir de investimentos públicos na perfuração de poços tubulares. Entretanto, essas fontes hídricas apresentam na maioria dos casos restrições de uso para dessedentamento humano, por apresentarem problemas de salinidade.A tecnologia da osmose reversa tem sido amplamente utilizada para o tratamento da água salobra, com experiências de êxito na maioria das localidades aonde têm sido implantadas as unidades de tratamento de água por dessalinização. Muitas comunidades rurais de Mossoró, RN, são abastecidas com água proveniente do aquífero Jandaíra, de elevada concentração de sais, a qual é tratada em dessalinizadores, possibilitando sua utilização para consumo humano. Nessas comunidades, o rejeito do processo da dessalinização não está recebendo qualquer tratamento ou destinação adequada, sendo despejado diretamente no solo e, quando utilizados na irrigação de culturas não há qualquer fundamentação técnico-científica para o seu uso, causando problemas de salinização nos solos. Devido aos impactos causados pelo uso de águas salobras ou de rejeito salino na irrigação no solo, para viabilizar a sua utilização deve-se sempre adotar algumas práticas especiais de manejo da água e do solo para o controle da salinidade. Sendo a maioria das culturas exploradas na região classificadas como sensíveis a moderadamente sensíveis à salinidade, surge a necessidade de melhor caracterizar essas águas, para se estabelecer o manejo adequado das plantas, solo e sistemas de irrigação. Assim, o presente trabalho objetivou avaliar a qualidade da água para fins de irrigação de comunidades rurais de Mossoró, abastecidas com águas salobras provenientes de poços tubulares, dotados de dessalinizadores, fornecendo estas informações como uma ferramenta de auxílio para o manejo adequado da utilização destas águas na irrigação. Foram selecionadas 30 comunidades rurais para realização das coletas de amostras das águas do rejeito gerado na dessalinização, purificadas e na sua forma natural (água salobra de poço). Nas amostras coletadas foram determinadas a condutividade elétrica da água (CEa), o pH e concentrações de Na+, Ca2+, K+, Cl-, HCO3 - e CO3 2-; além disso, a razão de adsorção de sódio (RAS). As análises das amostras de água foram interpretadas quanto aos riscos de salinidade, sodicidade, toxidade de íons e outros parâmetros de qualidade. Os resultados mostram que as águas dos poços das comunidades rurais estudadas possuem restrições para a sua utilização na agricultura, quanto aos riscos de salinização e sodificação do solo, principalmente as águas das comunidades: São Romão; Boa Fé e Pau Branco; as águas de rejeito da dessalinização possuem elevadas concentrações de sais, principalmente nas comunidades de Boa Fé e Puxa Boi, comprometendo a sua utilização para a irrigação e as águas dessalinizadas, embora possuírem baixos teores de sais têm restrições quanto a problemas de infiltração no solo, caso venham a ser empregadas para irrigação.
APA, Harvard, Vancouver, ISO, and other styles
31

Ferreira, Larissa Candian. "Comparação de leituras de turbidez de amostras de água bruta e tratada em diferentes equipamentos: contribuições à Portaria MS no 2914/2011." Universidade Federal de Viçosa, 2018. http://www.locus.ufv.br/handle/123456789/21849.

Full text
Abstract:
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2018-09-17T13:57:06Z No. of bitstreams: 1 texto completo.pdf: 1500002 bytes, checksum: 2b28d416576bc7c3dfcca6c710271a2b (MD5)<br>Made available in DSpace on 2018-09-17T13:57:06Z (GMT). No. of bitstreams: 1 texto completo.pdf: 1500002 bytes, checksum: 2b28d416576bc7c3dfcca6c710271a2b (MD5) Previous issue date: 2018-02-19<br>Coordenação de Aperfeiçoamento de Pessoal de Nível Superior<br>Neste trabalho, avaliou-se a confiabilidade analítica e diferenças entre leituras de turbidez de amostras de água bruta, decantada e filtrada da Estação de Tratamento de Água da Universidade Federal de Viçosa tendo em conta dois dos principais fatores de interesse na medição de turbidez: operadores e equipamentos. Foram utilizados quatro turbidímetros portáteis (três de mesma marca e modelo), seis equipamentos on line (cinco de mesma marca e modelo) e um de bancada. A pesquisa foi dividida em dois estudos: (i) Estudo 1, entre maio de 2015 e março de 2016, quando foram avaliadas diferenças entre leituras de turbidez realizadas por dois operadores com os equipamentos portáteis e de bancada; (ii) Estudo 2, entre de julho de 2016 e setembro de 2017, no qual foram avaliadas diferenças entre leituras fornecidas pelos equipamentos de bancada e on line. Nos dois estudos, o turbidímetro de bancada foi assumido como o equipamento padrão (aquele que forneceria os valores “verdadeiros” de turbidez). Tendo isso em conta e tomando como referência os limites especificados na norma brasileira de qualidade da água para consumo humano para turbidez de efluentes de filtros rápidos - 0,50 uT (máximo permitido) e 0,30 uT (recomendação), foram avaliadas a confiabilidade (acurácia) das medidas de turbidez, além da sensibilidade e especificidade dos equipamentos (respectivamente, a capacidade de detectar valores inferiores e acima dos valores de referência). Em geral, o teste de confiabilidade demonstrou que a acurácia das medidas fornecidas pelos demais equipamentos em relação ao turbidímetro de bancada foi baixa, particularmente para medidas abaixo de 0,3 uT no caso dos turbidímetros portáteis e entre 0,3-0,5 uT no caso dos equipamentos on line. Também em linhas gerais, os turbidímetros portáteis e on line apresentaram elevada sensibilidade, mas especificidade mais baixa, comparativamente ao equipamento de bancada. Testes estatísticos de diferença de médias mostraram que no Estudo 1 houve diferença significativa entre as leituras realizadas pelos dois operadores nas faixas de valores mais baixas de turbidez (até 0,50 uT); entre equipamentos, as diferenças foram maiores também para valores mais baixos de turbidez e diminuíram em mais valores altos (não houve diferença significativa na faixa de 5,1 a 10 uT). No Estudo 2, foram observadas diferenças significativas entre os todos os equipamentos e para todas os tipos de água, com o equipamento de bancada apresentando leituras maiores do que um dos equipamentos on line, porém mais baixas que as do outro. Não obstante, todas as diferenças foram muito pequenas em magnitude, particularmente nas leituras de turbidez de água filtrada. Conclui-se que o atendimento dos limites de turbidez de água filtrada especificados na norma brasileira de qualidade da água para consumo humano pode ser verificado independentemente do equipamento utilizado.<br>In this work, the analytical reliability and differences between turbidity readings of raw, settled and filtered water samples from the University of Viçosa water treatment plant were evaluated taking into account two of the main factors of interest in turbidity measurements: operators and instruments. Four portable turbidimeters (three of the same brand and model), six online instruments (five of the same brand and model) and one benchtop turbidimeter were used. The research was comprise of two separate studies: (i) Study 1, from May 2015 to March 2016, when differences between turbidity readings carried out by two operators using portable and benchtop instruments were compared; (ii) Study 2, from July 2016 to September 2017, in which differences between readings provided by the bench and the online instruments were evaluated. In both studies, the benchtop turbidimeter was assumed as the standard instrument (the one that would provide the "true" turbidity values). Taking this into account and having the Brazilian drinking-water quality standards for rapid sand filtration as references – 0.50 uT (maximum) and 0.30 uT (recommendation), the reliability (accuracy) of the turbidity measurements and the instrument’s sensitivity and specificity (respectively, the ability to detect values lower than and above the reference values) were evaluated. In general, the reliability test showed that the accuracy of the measurements provided by all other instruments relatively to the benchtop turbidimeter was low, particularly for measurements below 0.3 uT in the case of the portable turbidimeters, and for readings between 0.3-0.5 uT in the case of the online instrument. Generally, portable and online turbidimeters presented high sensitivity, but lower specificity, compared to benchtop instrument. The statistical tests showed that in Study 1 there were significant differences between readings carried out by the two operators in the lowest range values of turbidity (up to 0.50 uT); between instruments, the differences were also higher for lower turbidity values and decreased in higher values (there was no significant difference in the range of 5.1 to 10 uT). In Study 2, there were significant differences between all the equipment and for all waters types, with benchtop readings higher than those of one of the online turbidimeter, but lower than the other. Nevertheless, all differences were very small in magnitude, particularly for filtered water readings. It is concluded that compliance with the filtered water turbidity threshold values specified in the Brazilian drinking-water quality standard can be evaluated regardless of the type of turbidimeter used.
APA, Harvard, Vancouver, ISO, and other styles
32

CUNHA, Márcia Valéria Porto de Oliveira. "Importância da frequência de descarte de lodo na eficiência dos decantadores de estações de tratamento de água em ciclo completo." Universidade Federal do Pará, 2004. http://www.repositorio.ufpa.br:8080/jspui/handle/2011/1885.

Full text
Abstract:
Made available in DSpace on 2011-03-23T21:19:39Z (GMT). No. of bitstreams: 0<br>Item created via OAI harvest from source: http://www.bdtd.ufpa.br/tde_oai/oai2.php on 2011-03-23T21:19:39Z (GMT). Item's OAI Record identifier: oai:bdtd.ufpa.br:296<br>In this work, different periods of discharge of the sludge stored in the decanters of the ETA Bolonha had been evaluated, with the purpose to recommend the operational routine that presents the best ones results in the efficiency of the decanters. The three experimental phases had been divided in three stages: being in phase 1 evaluated the efficiency of the current operation routine of the decanters what is the total discharge of sludge in 12 in 12 days. In phase 2, the operational routine was modified to a daily discharge during the time of 5 minutes and so it coud take care of the recommendations of the executive project; by the other hand, in phase 3, the operational routine was modified again, discharge of sludge of 5 in 5 days during the time of 5 minutes, in order to getting better results of efficiency. In these three phases it was realized the control of total suspended solids, dimming and color in the effluent tributary and, as well as quantified and characterized the sludge generated in the decanters. With the research it was possible to observe that according to the point of view of efficiency of the decanters, the implemented operational routine in phase 3 (discherge of sludge to each 5 days) it was showed more adequate. By the way, it recommends that tests with other operational routines should be done in order to remove the sludge deposited in the decanters to diminish the losses of water of this operation. Moreover, it is important to study other ways to remove the deposited sludge in the intermediate tray of the decanter to prevent the accumulation of sludge on tray.<br>No trabalho foram avaliados três diferentes períodos de descarte do Iodo armazenado nos decantadores da ET A Bolonha, com a finalidade de recomendar a rotina operacional que apresenta os melhores resultados na eficiência dos decantadores. Para isso o trabalho foi dividido em três fases experimentais, sendo que na fase 1 foi avaliada a eficiência da atual rotina operacional dos decantadores, que é de descarga total do Iodo de 12 em 12 dias. Na fase 2 a rotina operacional foi alterada para descarga de Iodo diária durante o tempo de 5 minutos, para que se pudesse atender as recornendações do projeto executivo; e quanto na fase 3 a rotina operacional foi novamente alterada, descarga de Iodo de 5 em 5 dias durante o tempo de 5 minutos, em função de se obter melhores resultados de eficiêrlcia. Em todas as fases foram determinadas as variáveis sólidos suspensos totais, turbidez e cor aparente no afluente e efluente dos decantadores, bem como determinado a concentração de sólidos do Iodo gerado nos decantadores e no sistema auxiliar de remoção de Iodo da bandeja intermediária. Além disso, em todas as fases, foi quantificado o volume de Iodo descartado e a produção mensal de sólidos gerados pelo Iodo. Com a pesquisa foi possível observar que sob o ponto de vista de eficiência dos decantadores, a rotina operacional implementada na fase 2 (remoção diária do Iodo) e na fase 3 (descargas de Iodo a cada 5 dias) apresentaram resultados semelhantes, porém, com relação a geração de resíduos a rotina operacional implementada na fase 3 se mostrou mais adequada, já que nesta fase houve um decréscimo médio de 48% em relação a fase 1. Assim, recomenda-se que seja estuda a rotina implementada na fase 3 deste estudo em todos os seis decantadores da ETA Bolonha.
APA, Harvard, Vancouver, ISO, and other styles
33

D'Acampora, Bárbara Heliodora Alves. "O uso da arquitetura da paisagem no tratamento final dos efluentes de estações de tratamento de esgotos em São José/SC." reponame:Repositório Institucional da UFSC, 2013. https://repositorio.ufsc.br/handle/123456789/107100.

Full text
Abstract:
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências Tecnológicas, Programa de Pós-Graduação em Arquitetura e Urbanismo, Florianópolis, 2013.<br>Made available in DSpace on 2013-12-05T23:12:46Z (GMT). No. of bitstreams: 1 321674.pdf: 8657291 bytes, checksum: bd14220d5ac3edf08fcd3baee39d2f58 (MD5) Previous issue date: 2013<br>O crescimento populacional e a falta de planejamento são graves problemas no desenvolvimento das cidades brasileiras, que geram a deficiência de coleta e de tratamento de esgotos urbanos, causando problema de saúde pública. Por sua vez, ocasionam também a carência de espaços verdes, que apesar de possuírem áreas de vegetação, a sua qualidade não está ligada às necessidades da população, atingindo a qualidade de vida. Dentro desse enfoque, o Município de São José/SC possui uma deficiência de vegetação urbana e um único sistema de tratamento que cobre uma parte ínfima da área urbana. Portanto, esta pesquisa tem por objetivo articular as possíveis conexões entre a arquitetura da paisagem e o tratamento final de efluentes das ETEs no Município de São José/SC. O estudo possui análise espacial de campo e solução de problemas específicos para sociedade, através do tratamento de dados quali-quantitativos, revisão de material bibliográfico e documental sobre os tratamentos de esgotos urbanos, que unem-se aos espaços verdes em São José. O tratamento de esgoto com Jardins Filtrantes, utilizado como espaço verde é uma alternativa viável como solução ao complemento de tratamento de esgotos urbanos convencionais, criando uma paisagem concebida como um jardim ou parque público. Constata-se, portanto, os efeitos positivos dessa integração sobre o ambiente, a população e a economia urbana josefense, através de uma solução integrada à natureza.<br><br>Abstract : Population growth and lack of planning are serious problems in the Brazilian cities' development, which generates the deficiency on collection and on treatment of urban sewage, causing public health problem. By other hand, leads also to the lack green spaces, which despite having areas of vegetation, its quality is not linked to the needs of the population, affecting the quality of life. Under this approach, the City of São José/SC has a deficiency of urban greenery and a single treatment system that covers a tiny part of the urban area. Therefore, this research aims to articulate the possible connections between landscape architecture and final treatment of effluent from the STPs in São José/SC. The study has a field's spatial analysis on troubleshooting specific for society, data processing qualitative and quantitative data, bibliography and documentary about the treatment of urban sewage, uniting the green spaces of São José. The sewage treatment by filtering gardens, used as green space is a viable alternative solution to complement conventional urban sewage treatment, creating a landscape conceived as a garden or public park. Noticing, therefore, the positive effects of such integration on the environment, population and urban economy of São José through an integrated solution to nature.
APA, Harvard, Vancouver, ISO, and other styles
34

Gimenes, Guilherme 1988. "Disposição de lodo de estação de tratamento de água em reator UASB." [s.n.], 2014. http://repositorio.unicamp.br/jspui/handle/REPOSIP/258436.

Full text
Abstract:
Orientadores: Edson Aparecido Abdul Nour, Ariovaldo José da Silva<br>Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo<br>Made available in DSpace on 2018-08-26T02:24:01Z (GMT). No. of bitstreams: 1 Gimenes_Guilherme_M.pdf: 1688310 bytes, checksum: c47bb53b0e7201268e36438676a927e5 (MD5) Previous issue date: 2014<br>Resumo: A busca por soluções viáveis para a disposição adequada do lodo de Estações de Tratamento de Água (ETA), tem se mostrado uma preocupação crescente de diversas empresas e companhias de saneamento. Uma das alternativas é o lançamento na rede coletora de esgoto. No entanto, deve ser avaliada criteriosamente a capacidade da Estação de Tratamento de Esgoto (ETE) em receber tal resíduo. Nesta linha de raciocínio, o presente trabalho visou avaliar o impacto do lodo de ETA, da qual utilizou PAC como coagulante, para a biomassa anaeróbia de um reator UASB por meio do ensaio da Atividade Metanogênica Específica (AME) e verificar também a evolução da concentração de alumínio e carbono orgânico total (COT) no lodo da ETE após a mistura com o lodo da ETA. Os ensaios de AME foram realizados segundo a metodologia adaptada de Aquino et al. (2007). Foram testadas concentrações de lodo de ETA de 1, 2, 4, 6, 10, 12,5, 15, 20 e 30 g SST.L-1 e o frasco controle (sem lodo de ETA) como elemento de comparação. Como resultados foi possível observar que, estatisticamente, não houve diferenças significativas no valor da AME entre o frasco controle e as concentrações de 1, 2, 4 e 6 g SST.L-1. Já para as concentrações acima de 6 g SST.L-1 houve uma redução considerável do valor da AME, comparadas com o frasco controle. Quanto à concentração de alumínio, foi verificado que conforme aumentou a dosagem de lodo da ETA, aumentou também a concentração de alumínio no lodo, desta forma, contribuindo para a hipótese de que o alumínio pode provocar impacto negativo à biomassa do reator UASB, pois quanto maior a concentração de alumínio, menor o valor da AME. Também foi observado que o aumento da concentração de lodo de ETA diminui a porcentagem de carbono orgânico total. Por fim, pela metodologia proposta, foi demonstrada a viabilidade de lançamento do lodo das ETA na ETE, de forma que a concentração de lodo de ETA no reator UASB se limite a 6 g SST.L-1 para não provocar impacto significativo na atividade biológica<br>Abstract: The search for viable solution to disposal of sludge from water treatment plants (WTP) has shown a growing concern for many businesses and sanitation companies. One alternative is to launch in the sewage disposal system. However, it should be carefully evaluated the ability of WWTP to receive such waste. This line of reasoning, the present study aimed to evaluate the impact of WTP sludge, that used PAC as a coagulant for the anaerobic biomass of a UASB reactor using assay of Specific Methanogenic Activity (SMA) and also check the evolution of the aluminum concentration and TOC in the WWTP sludge after mixing with the WTP sludge. Assays were performed in Duran flask of 250 mL according to the methodology adapted from Aquino et al. (2007). WTP sludge concentrations of 1, 2, 4, 6, 10, 12,5, 15, 20 and 30 g SST.L-1 and the control flask (without WTP sludge) as a comparator were tested. As a result it was observed that, statistically, there were no significant differences in the SMA value between the control flask and the concentrations of 1, 2, 4 and 6 g SST.L-1. Compared to the control flask, concentrations above 6 g SST.L-1 there was a considerable reduction in the value of SMA. On aluminum concentration, was checked that rising the dosage of wtp sludge also rise the concentration of aluminum in the wwtp sludge, thereby contributing to the hypothesis that aluminum can cause negative impact on the UASB reactor biomass, because how higher is aluminum concentration, lower is the SMA. It was also observed that with increasing concentration of WTP sludge decreases total organic carbon percentage. Finally, by the proposed methodology, the feasibility of launching the WTP sludge in WWTP was demonstrated, so the concentration of WTP sludge in the UASB reactor is limited to 6 g SST.L-1 not to cause significant impact on the biological activity<br>Mestrado<br>Saneamento e Ambiente<br>Mestre em Engenharia Civil
APA, Harvard, Vancouver, ISO, and other styles
35

Wosniak, Alcely Jose. "Avaliação em escala piloto do uso de membrana de osmose reversa para tratamento de água para uso industrial." reponame:Repositório Institucional da UFPR, 2018. http://hdl.handle.net/1884/46453.

Full text
Abstract:
Orientador : Profª. Drª. Daniela Neuffer<br>Co-orientador : Profª. Drª. Karen Juliana do Amaral<br>Dissertação (mestrado) - Universidade Federal do Paraná, Setor de Tecnologia, Programa de Mestrado Profissional em Meio Ambiente Urbano e Industrial, em parceria com o Serviço Nacional de Aprendizagem Industrial e a Universität Stuttgart. Defesa: Curitiba, 24/11/2015<br>Inclui referências: f. 96-109<br>Resumo: A utilização de rios degradados deve ser visto como uma alternativa viável para aumento da disponibilidade de água aos diversos usos, inclusive para fins industriais. A água a ser utilizada na indústria requer muitas vezes qualidade superior àquela destinada ao consumo humano. Com base nas exigências de qualidade e no conhecimento dos processos existentes, é possível obter água com qualidade adequada ao uso industrial a que se destina. Curitiba e a Região Metropolitana (RMC) apresentam um alto grau de industrialização e um conflito de uso de água potável para fins industriais. A Estação de Tratamento de Água Industrial Araucária (ETAIA) é uma estação de tratamento de água para reúso indireto e não potável. Atualmente, a ETAIA é composta pelos processos de oxidação, coagulação, decantação e filtração, resultando numa qualidade da água tratada fora dos padrões estabelecidos pelas indústrias que a utilizam. Desta forma, este trabalho tem como objetivo geral avaliar a operação de uma planta de osmose reversa (OR) em escala piloto para póstratamento da água produzida na ETAIA, tendo em vista a qualidade final do permeado e a mistura com a água produzida na estação. Para o estudo, foram avaliadas a qualidade do filtrado de um filtro de carvão ativado granular (GAC) e a qualidade do permeado da OR. Para verificar o desempenho da OR, foram analisados os parâmetros no permeado: turbidez, condutividade, detergente sintético não biodegradável (Alquio Benzeno Sulfanato de Sódio - ABS), cloretos, fluoretos, manganês, ferro, fosfato, sulfatos, dureza, nitrogênio amoniacal, carbono orgânico total (TOC), e sílica. Também houve a avaliação da retenção, rejeição e taxa de permeabilidade da OR para dois tipos de membranas ESPA 1 - 4040 e ESPA 2 LD - 4040. Os resultados demonstraram que filtro de GAC removeu 100% do cloro residual, e que a membrana ESPA 1 - 4040 apresentou um fluxo de permeado 32,4 L/(m² h) ou 63,5% do fluxo padrão e uma retenção salina 97,65%. A membrana ESPA 2 LD - 4040 apresentou um fluxo 32,8 L/(m² h) ou 77,3% do fluxo padrão e uma retenção salina 97,79%. Houve a necessidade de três lavagens químicas na membrana, devido à colmatação de origem orgânica. Essas lavagens foram agressivas, reduzindo a vida útil da membrana. Em comparação com a água produzida na ETAIA, a água gerada na OR apresentou uma melhor qualidade, atendendo a todos requisitos de qualidade dos clientes. O custo da água produzida no sistema de OR foi 153% maior que o custo da água produzida na ETAIA. A água produzida na ETAIA não é apropriada para alimentação de um equipamento de OR nem para atendimento as industrias. A membranas ESPA 2 LD - 4040 apresentou melhor resultados de qualidade e desempenho. A aplicação da OR para o tratamento da água produzida pela ETAIA se mostrou eficaz, produzindo um permeado com a qualidade dentro dos padrões exigidos no contrato com as indústrias, podendo assim ser utilizada como pós-tratamento para água produzida na ETAIA. No entanto, a água de alimentação tratada na ETAIA não é apropriada para abastecer a OR, e que, caso seja operada em escala real, haverá prejuízo para o desempenho da OR ao longo do tempo de operação. Palavras-chave: Água industrial. Torre de resfriamento. Autópsia da membrana.<br>Abstract: The recovery of degraded water sources should be seen as a viable alternative to increase the availability of water for various uses, including for industrial purposes The water to be used in industry often requires superior to that intended for human consumption. Based on the quality requirements and knowledge of existing processes, it is possible to obtain water quality suitable for the industrial use to which it is intended. Curitiba and Metropolitan Region (RMC) have a high degree of industrialization and a conflict of use of drinking water for industrial purposes. Industrial Water Treatment Plant Araucaria (ETAIA) is a water treatment plant for reuse indirect and not drinkable. Currently, ETAIA is composed of the processes of oxidation, coagulation, sedimentation and filtration, resulting in treated water quality standards set out by the industries that use. Thus, this study is to evaluate the overall operation of the reverse osmosis (OR) for a post-treatment of water produced in ETAIA, considering the final quality of the permeate and mixing with the water produced at the station. For the study, we evaluated the quality of filtered of a granular activated carbon filter (GAC) and the quality of the OR permeate. To verify the performance of the RO, the concentrations of the turbidity parameters were analyzed, conductivity, non-biodegradable synthetic detergent (Alquio Benzene Sodium Sulfanato - ABS), chlorides, fluorides, manganese, iron, phosphate, sulphate, hardness, ammonia nitrogen, organic carbon total (TOC), and silica in the permeate, with an average removal observed 90%. There was also the retention evaluation, OR rejection and permeability rate for both types of membranes ESPA 1 - 4040 e ESPA 2 LD - 4040. The results showed that GAC filter removed 100% of residual chlorine and the membrane 1 ESPA - 4040 showed a permeate flow of 32.4 l / (m² h) or 63.5% of the standard flow and a saline retention 97.65%. The membrane 2 ESPA-4040 showed a LD flow 32.8 L / (m² h) or 77.3% of the standard flow and a saline retention 97.79% .There was the need for three chemical washes, due to clogging of the membrane organic origin. These washings were aggressive, reducing the life of the membrane. The cost of water produced by the RO system was 153% higher than the cost of water produced in ETAIA. The ESPA 2 membranes LD-4040 presented better results of quality and performance. The application of OR for the treatment of water produced by ETAIA proved effective, producing a permeated with the quality standards required in the contract with the industries, and thus can be used as posttreatment for produced water at ETAIA. However the feed water treated in ETAIA is not suitable for fuel OR, and that, if it is operated in real scale, there will be damage to the performance of OR over time. Keywords: Industrial water. Cooling tower. Membrane autopsy
APA, Harvard, Vancouver, ISO, and other styles
36

Reis, Renan Felicio dos. "Estudo de influência de cobertura plástica na remoção de água de lodos de estações de tratamento de água em leitos de drenagem." Universidade Federal de São Carlos, 2011. https://repositorio.ufscar.br/handle/ufscar/4301.

Full text
Abstract:
Made available in DSpace on 2016-06-02T20:00:37Z (GMT). No. of bitstreams: 1 3585.pdf: 4834479 bytes, checksum: 5a0924e0311d45a52820620dbafa4f6a (MD5) Previous issue date: 2011-03-23<br>Universidade Federal de Minas Gerais<br>Most of Water Treatment Plant (WTP) for public supply in Brazil use surface water as source and conventional complete cycle as treatment system. In this type of treatment wastewater are restrained/generated which vary mainly according to the type and amount of chemical added and the characteristics of the water resource. This wastewater is found mainly in clarifiers (sludge) and backwash water filter (BWF) from WTP. Unfortunately, most of Brazilian WTP launches its waste directly into water resources, violating Brazilian Law 9605 published in 1998. There are mechanical and natural technologies for water removal from wastewater restrained during the treatment. Once known that wastewater from WTP has fluid characteristic, some technologies to remove its water have been developed. A natural one is the drainage bed, developed and proposed by Cordeiro (2001). The drainage bed has basically two stages: drainage and evaporation. This dissertation presents results of a study, whose centre objective was to achieve improvements in water sludge removal restrained in clarifiers by the use of plastic cover (evaporation stage). Results of effective tests in prototypes located in Sao Carlos WTP (Sao Paulo State) with plastic cover have showed that this roof (commercial reference PVC 0.30 milimeters) uses has accelerated the evaporation process, and has protected sludge from rain. The height of the roof that presented the best result was 0.20 meters in relation to the board of prototype, realizing to obtain a sludge 56% dryer than in tests without the roof. Preliminary tests in laboratory scale generated a promising scenario for the use of cationic polymer in large scale doubling the efficiency of the initial drainage of sludge. However, other laboratory tests with different characteristics of geotextile blanket only confirmed the superiority of using woven blanket type with surface density of 600 g/m² (which had already been used in other studies), compared to the others, in reference to obtain better efficiency at the initial drainage of water present in raw sludge.<br>A maior parte das Estações de Tratamento de Água (ETAs) para abastecimento existente no Brasil se utiliza de captação de águas superficiais e sistema de tratamento de ciclo completo convencional. Neste tratamento são retidos/gerados resíduos que variam principalmente segundo o tipo e quantidade de produto químico adicionado e as características do manancial de captação. Estes resíduos são encontrados principalmente nos decantadores (lodo) e na água de lavagem dos filtros (ALF) das ETAs. Infelizmente, a maioria das ETAs brasileiras lança seus resíduos diretamente em corpos d água, infringindo disposições da Lei 9.605/98. Existem tecnologias mecanizadas e naturais para remoção de água dos resíduos retidos no tratamento. Uma vez que possuem característica fluida, foram desenvolvidas algumas tecnologias para remoção de suas águas. Uma tecnologia natural para remoção de águas de resíduos de ETAs é o leito de drenagem, desenvolvido e proposto por Cordeiro (2001). O leito de drenagem possui basicamente duas etapas envolvidas: drenagem e evaporação. Esta pesquisa apresenta resultados de um estudo, cujo objetivo central foi alcançar melhorias na remoção da água de lodo retido nos decantadores através da utilização de cobertura plástica no leito de drenagem (etapa de evaporação). Resultados obtidos nesta pesquisa para ensaios realizados em protótipos de leitos de drenagem instalados na ETA de São Carlos-SP demonstraram que, quando se utiliza cobertura plástica (referência comercial PVC 0,30 mm), o processo de evaporação da água presente no lodo é acelerado e a ocorrência de precipitação não interfere em momento algum na remoção de água do lodo. A altura da cobertura em relação ao protótipo que apresentou os melhores resultados foi de 0,20 m, permitindo-se obter um lodo final até 56% mais seco que na ausência de cobertura. Ensaios realizados em escala laboratorial para condicionamento prévio do lodo bruto com polímero catiônico apresentaram resultados promissores para sua utilização em maior escala, duplicando a eficiência da drenagem inicial do lodo. Entretanto, outros ensaios laboratoriais com mantas geotêxteis de características distintas apenas confirmaram a superioridade da utilização de manta do tipo tecida de densidade superficial 600g/m² (que já havia sido utilizada em outras pesquisas) em relação às demais, no que se refere à obtenção de melhor eficiência na drenagem inicial da água presente no lodo bruto.
APA, Harvard, Vancouver, ISO, and other styles
37

Katayama, Victor Takazi. "Quantificação da produção de lodo de estações de tratamento de água de ciclo completo: uma análise crítica." Universidade de São Paulo, 2012. http://www.teses.usp.br/teses/disponiveis/3/3147/tde-19072013-161144/.

Full text
Abstract:
Grande parte do lodo gerado em ETAs no Brasil ainda é disposta em rios ou em aterros sanitários. Contudo, principalmente em grandes centros urbanos, condições de licenciamento ambiental restritivas e custos logísticos crescentes tem levantado interesse em usos benéficos para esse resíduo. Um obstáculo para a mudança de paradigma recai no fato de que muito raramente operadores e projetistas de ETAs nacionais conseguirem prever, com algum grau de confiabilidade, a massa e volume de resíduos produzidos pelo tratamento da água bruta. Geralmente, usa-se para esse fim fórmulas empíricas, que relacionam a produção de lodo à concentração de sólidos em suspensão totais (SST) na água bruta e à dosagem de produtos químicos. Os objetivos deste trabalho são: comparar o desempenho de dois dos principais métodos quantitativos de estimativa de produção de lodo o método de fórmulas empíricas, e o do balanço de massa; investigar a prática disseminada de se estimar a concentração de sólidos em suspensão totais na água bruta por meio de modelos de regressão linear com a turbidez como variável independente; e delinear condições para a aplicação dessa correlação. Foram utilizados dados de seis ETAs de ciclo completo operadas pela SABESP (ABV, Alto Cotia, Cubatão, Guaraú, Franca e Presidente Prudente), além de dados de monitoramento de 130 estações de monitoramento de águas superficiais da CETESB. Os resultados sugerem que a identificação de correlações significativas entre concentração de SST e turbidez é elusiva, e não constitui tarefa trivial. Do universo de 130 estações da CETESB, somente 7 apresentaram correlação significativa; das ETAs, somente Presidente Prudente. Modelos de regressão alternativos utilizando outras variáveis (cor, vazão média mensal e mês), combinadas com a turbidez ou isoladamente, foram desenvolvidos. Somente a inclusão do mês como variável categórica foi capaz de aumentar o poder explicativo do modelo baseado exclusivamente na turbidez, sugerindo que a relação entre turbidez e concentração de SST é variável sazonalmente. Mediante a comparação com balanços de massa, foram identificados alguns fatores que afetam o poder de predição da fórmula empírica desenvolvida pela American Water Works Association, algumas vezes de maneira drástica. Em geral, conclui-se que o uso de fórmulas empíricas principalmente em conjunto com modelos de regressão entre concentração de SST e turbidez possa não ser recomendável.<br>Most of the water treatment plant (WTP) residuals generated in Brazil is still discharged in water bodies, or disposed of in landfills. However, especially in large urban areas, ever stringent conditions for environmental permits e rising logistical costs have put into focus beneficial uses for those residuals. A major obstacle for paradigm change in that aspect lies in the fact that very rarely water treatment plant operators and designers are able to predict with some degree of certainty the mass and volume of residuals produced by the treatment process. Usually, empirical formulas are used for that end, which relates the residuals production rate to the concentration of total suspended solids (TSS) in the raw water, and the chemicals dose. The objectives of this work are: to compare the performance of two of the main quantitative estimation methods for residuals production the empirical formulas and the mass balance; to investigate the widespread practice of estimating the concentration of TSS using turbidity as a surrogate; and to identify the conditions under which such procedure is acceptable. For that end, data from six WTPs operated by SABESP (ABV, Alto Cotia, Cubatão, Guaraú, Franca e Presidente Prudente), plus 130 surface water monitoring stations operated by CETESB, was analyzed. Alternative regression models, employing other independent variables (color, average monthly flow and month) singly or in combination with turbidity, were developed. Only the inclusion of the month as a categorical variable was capable of enhancing the explaining power of the turbidity model, suggesting that the relation between turbidity and TSS concentration is seasonally variable. The results suggest that identification of such significant correlations between TSS concentration and turbidity is elusive at best, and doesn\'t amount to a trivial task. Out of the universe of 130 monitoring stations, in only 7 a good degree of correlation was found; of the WTPs, that was the case only in Presidente Prudente. Through the comparison with the mass balances, some factors that affect the predictive power of the American Water Works Association sometimes drastically a were identified. In general, it is concluded that the use of empirical formulas especially when combined with turbidity and TSS concentration regression models may not be recommended.
APA, Harvard, Vancouver, ISO, and other styles
38

Martinez, Juan Gabriel Bastidas. "Avaliação de desempenho de misturas betuminosas com adição de lodos de eta e de ete." reponame:Repositório Institucional da UnB, 2014. http://repositorio.unb.br/handle/10482/16690.

Full text
Abstract:
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil, 2014.<br>Submitted by Ana Cristina Barbosa da Silva (annabds@hotmail.com) on 2014-10-22T17:42:45Z No. of bitstreams: 1 2014_JuanGabrielBastidasMartinez.pdf: 1656961 bytes, checksum: 7869b12a771e890895d24b5a7af2d95c (MD5)<br>Approved for entry into archive by Tania Milca Carvalho Malheiros(tania@bce.unb.br) on 2014-10-31T16:03:20Z (GMT) No. of bitstreams: 1 2014_JuanGabrielBastidasMartinez.pdf: 1656961 bytes, checksum: 7869b12a771e890895d24b5a7af2d95c (MD5)<br>Made available in DSpace on 2014-10-31T16:03:20Z (GMT). No. of bitstreams: 1 2014_JuanGabrielBastidasMartinez.pdf: 1656961 bytes, checksum: 7869b12a771e890895d24b5a7af2d95c (MD5)<br>As Estações de Tratamento de Água (ETA) e de Esgoto (ETE) geram como subprodutosde sua operação uma grande quantidade de lodo, que é considerado resíduo sólido pela ABNT10.004/2004 (Associação Brasileira de Normas Técnicas). A disposição final dos resíduos, semum adequado gerenciamento, pode resultar em danos aos seres humanos e ao meio ambiente constituindo-se em passivo ambiental a evitar. Este trabalho teve como finalidade verificar a possibilidade de utilização dos referidos resíduos em concreto betuminoso usinado a quente proporcionando a sua melhoria de comportamento, sem levar em conta nessa fase inicial os custos diretos do tratamento e nem do passivo ambiental. Para possibilitar a incorporação dos resíduos lodos de ETA e de ETE no Concreto Asfáltico utilizou-se um moinho mecânico a fim de tornar o material passante pela peneira número 200. Os resíduos foram adicionados à misturas de duas formas: i) via úmida; ii) via seca. Na primeira, se colocaram em várias temperaturas de secagem (200°C, 300°C, 500°C, 800°C e seco ao ar) ao ligante asfáltico, já no segundo caso, realizando secagem a 175 °C para logo ser adicionado ao agregado miúdo. A interação ligante-lodos foi avaliada por meio dos ensaios de massa especifica, consistência e perda de massa ou variação RTFOT. Os lodos de ETA calcinados a 500°C apresentaram melhoria nas propriedades mecânicas e de adesividade. Já os lodos de ETE, secos à temperatura de aquecimento do ligante, e adicionados sobre o agregado miúdo apresentaram incrementos nas propriedades mecânicas. O estudo permitiu concluir que a utilização dos lodos de ETA ede ETE no concreto betuminoso para fins de construção rodoviária é viável quanto aos aspectos técnico e ambiental, sendo que pesquisas futuras serão importantes para um maior entendimento do comportamento dessas misturas e validação das conclusões a que se chegou. _______________________________________________________________________________________ ABSTRACT<br>Water Treatment Stations (WTS) and Sewage Treatment Stations (STS) generates alarge amount of sludge as products of their operations, these products are considered solid wasteby the ABNT 10004/2004 (Associação Brasileira de Normas Técnicas), and, without a propermanagement, the final disposal of waste can result harmful to the humanity and to theenvironment by cause pollution. So, that is an environmental issue to be avoided. This studyaimed to verify the usability of such waste in asphalt binders for hot asphalt concrete to knowif is this mixture could provide an improvement in its behavior, without taking into account, inthis initial phase, the direct costs of treatment and/or environmental liabilities. To facilitate theincorporation of WTS and STS sludge waste into the asphalt concrete was used a mechanicmill, in order to make the material pass through the sieve number 200. The residues were addedto the mixture by two ways: i) dry, and ii) wet. The first mixture was made subjecting thesamples to several high drying temperatures (200°C, 300°C, 500°C, 800°C and air dried) tothen add the asphalt binder; in the second case, the sludge was dried at 175 °C and added intothe fine aggregate. The sludge-ligand interaction was evaluated by the specific gravity tests, theconsistency and by the weight loss or variation RTFOT. The calcined WTS sludge (500 °C)showed improvement in mechanical and adhesion properties. While the STS sludge, dried atthe binder heating temperature, and added over the fine aggregate, showed increase only inmechanical properties. Therefore, the study conclude that the use of WTS and STS sludge’s inasphalt concrete, for road construction, is viable for technical and environmental aspects,however, future studies are needed to validate these results.
APA, Harvard, Vancouver, ISO, and other styles
39

Moura, José Antônio de [UNESP]. "Estudo da eficiência de estações de tratamento de esgoto - RTE e estações de tratamento de água - ETA na elimnação de resíduos de estrógenos naturais e sintéticos na UGRHI-13 (Tietê-Jacaré)." Universidade Estadual Paulista (UNESP), 2009. http://hdl.handle.net/11449/105689.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:35:06Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-02-13Bitstream added on 2014-06-13T21:07:12Z : No. of bitstreams: 1 moura_ja_dr_araiq.pdf: 8808948 bytes, checksum: f63a9b5491cfa36bc643a8c451e0e98b (MD5)<br>Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)<br>Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)<br>Até a década de 1980, o foco da contaminação dos mananciais esteve associado unicamente às atividades produtivas (indústria e agricultura). Os principais contaminantes em estudo eram os metais pesados, pesticidas e substâncias presentes em resíduos industriais. Com o avanço de estudos toxicológicos foram identificados efeitos sobre o sistema hormonal e imunológico em organismos pela ação de diversas substâncias que não eram enfocadas em estudos ambientais. Associado a isso foram desenvolvidas técnicas analíticas capazes de detectar e quantificar estas substâncias em concentrações diminutas (ng a μg L-1) como fármacos, hormônios naturais e sintéticos, detergentes, pesticidas, entre outros. Alguns destes “novos” contaminantes são chamados micropoluentes orgânicos e possuem propriedade de alteradores endócrinos. A existência de poucos estudos publicados sobre alteradores endócrinos em mananciais e/ou em bacias hidrográficas brasileiras, motivou a realização desta pesquisa de caráter multidisciplinar na UGRHI-13 - Bacia Hidrográfica Tietê- Jacaré, em que se propôs avaliar a eficiência das Estações de Tratamento de Esgoto – ETE e Estações de Tratamento de Água – ETA na eliminação de alguns estrógenos naturais (17-estradiol e estrona) e sintético (17 - etinilestradiol). A determinação foi baseada em método otimizado e validado incluindo SPE (C-18) para extração e pré-concentração dos anitos em amostras de esgoto bruto e tratado (250 -500 mL) e águas (1000 mL), e analise por HPLC/Fluorescência. Os limites de quantificação dos métodos validados foram 6,25 ng L-1 para E2 e EE2 e 0,5 μg L-1 para E1, para todas as matrizes estudadas. As amostras foram obtidas no período de maio de 2006 a julho de 2008, envolvendo 14 dos 34 municípios da UGRHI-13. Com base neste estudo, foi observada a baixa eficiência, (menor que 50%)...<br>Until the 1980’s, the focus of the contamination of water sources was only associated to productive activities (industry and agriculture). The main pollutants in study were the heavy metals, pesticides and industrial waste substances.With the advances in toxicological studies have identified effects on the hormonal and immunological system in organisms by the action of several substances that were not focused in environmental studies. In addition, analytical techniques capable to detect and quantify substances like drugs, natural and synthetic hormones, detergents, pesticides, among others in trace concentrations (ng L-1 up to μg L-1) were developed. These new pollutants are called organic micropollutants or endocrine disrupters. There are few studies published on endocrine modifiers in water source and/or in Brazilian hydrographic basin, it motivated the accomplishment of this research in the multidisciplinary nature of UGRHI-13 Tietê-Jacaré’s hydrographic basin, which proposed to evaluate the efficiency in municipal water treatment plants - WTP and wasterwater treatment plants- WWTP elimination efficiency of elimination of some natural estrogens (17  estradiol and estrone) and synthetic (17 - ethinylestradiol). The determination was based on methods optimized and validated in this research group, which involved the extraction stages and pré-concentration of samples of affluent (250 mL), effluent (500 mL) wastewaters and the water (1000 mL), using SPE (C-18) and HPLC//Fluorescence analysis. The quantification limits of the methods were; 6.25 ng L-1, 6.25 ng L-1 and 0.5 μg L-1 for E2, EE2 and E1, respectively. The samples were collected between May 2006 and July 2008, involving 14 of the 34 municipal districts of UGRHI-13. In this study, the low efficiency (< 50 %) in the removal of these pollutants was observed in WWTP, which used lagoons of stabilization... (Complete abstract click electronic access below)
APA, Harvard, Vancouver, ISO, and other styles
40

Moura, José Antônio de. "Estudo da eficiência de estações de tratamento de esgoto - RTE e estações de tratamento de água - ETA na elimnação de resíduos de estrógenos naturais e sintéticos na UGRHI-13 (Tietê-Jacaré) /." Araraquara : [s.n.], 2009. http://hdl.handle.net/11449/105689.

Full text
Abstract:
Orientador: Mary Rosa Rodrigues de Marchi<br>Banca: Maria Del Pilar Taboada Sotomayor<br>Banca: Maria Lúcia Ribeiro<br>Banca: Denilson Teixeira<br>Banca: Eny Maria Vieira<br>Resumo: Até a década de 1980, o foco da contaminação dos mananciais esteve associado unicamente às atividades produtivas (indústria e agricultura). Os principais contaminantes em estudo eram os metais pesados, pesticidas e substâncias presentes em resíduos industriais. Com o avanço de estudos toxicológicos foram identificados efeitos sobre o sistema hormonal e imunológico em organismos pela ação de diversas substâncias que não eram enfocadas em estudos ambientais. Associado a isso foram desenvolvidas técnicas analíticas capazes de detectar e quantificar estas substâncias em concentrações diminutas (ng a μg L-1) como fármacos, hormônios naturais e sintéticos, detergentes, pesticidas, entre outros. Alguns destes "novos" contaminantes são chamados micropoluentes orgânicos e possuem propriedade de alteradores endócrinos. A existência de poucos estudos publicados sobre alteradores endócrinos em mananciais e/ou em bacias hidrográficas brasileiras, motivou a realização desta pesquisa de caráter multidisciplinar na UGRHI-13 - Bacia Hidrográfica Tietê- Jacaré, em que se propôs avaliar a eficiência das Estações de Tratamento de Esgoto - ETE e Estações de Tratamento de Água - ETA na eliminação de alguns estrógenos naturais (17-estradiol e estrona) e sintético (17 - etinilestradiol). A determinação foi baseada em método otimizado e validado incluindo SPE (C-18) para extração e pré-concentração dos anitos em amostras de esgoto bruto e tratado (250 -500 mL) e águas (1000 mL), e analise por HPLC/Fluorescência. Os limites de quantificação dos métodos validados foram 6,25 ng L-1 para E2 e EE2 e 0,5 μg L-1 para E1, para todas as matrizes estudadas. As amostras foram obtidas no período de maio de 2006 a julho de 2008, envolvendo 14 dos 34 municípios da UGRHI-13. Com base neste estudo, foi observada a baixa eficiência, (menor que 50%)... (Resumo completo, clicar acesso eletrônico abaixo)<br>Abstract: Until the 1980's, the focus of the contamination of water sources was only associated to productive activities (industry and agriculture). The main pollutants in study were the heavy metals, pesticides and industrial waste substances.With the advances in toxicological studies have identified effects on the hormonal and immunological system in organisms by the action of several substances that were not focused in environmental studies. In addition, analytical techniques capable to detect and quantify substances like drugs, natural and synthetic hormones, detergents, pesticides, among others in trace concentrations (ng L-1 up to μg L-1) were developed. These "new" pollutants are called organic micropollutants or endocrine disrupters. There are few studies published on endocrine modifiers in water source and/or in Brazilian hydrographic basin, it motivated the accomplishment of this research in the multidisciplinary nature of UGRHI-13 Tietê-Jacaré's hydrographic basin, which proposed to evaluate the efficiency in municipal water treatment plants - WTP and wasterwater treatment plants- WWTP elimination efficiency of elimination of some natural estrogens (17  estradiol and estrone) and synthetic (17 - ethinylestradiol). The determination was based on methods optimized and validated in this research group, which involved the extraction stages and pré-concentration of samples of affluent (250 mL), effluent (500 mL) wastewaters and the water (1000 mL), using SPE (C-18) and HPLC//Fluorescence analysis. The quantification limits of the methods were; 6.25 ng L-1, 6.25 ng L-1 and 0.5 μg L-1 for E2, EE2 and E1, respectively. The samples were collected between May 2006 and July 2008, involving 14 of the 34 municipal districts of UGRHI-13. In this study, the low efficiency (< 50 %) in the removal of these pollutants was observed in WWTP, which used lagoons of stabilization... (Complete abstract click electronic access below)<br>Doutor
APA, Harvard, Vancouver, ISO, and other styles
41

Marguti, André Luiz. "Efeito do recebimento de lodos oriundos de estações de tratamento de água nos processos de tratamento de esgotos por lodos ativados convencional." Universidade de São Paulo, 2012. http://www.teses.usp.br/teses/disponiveis/3/3147/tde-06062013-155940/.

Full text
Abstract:
Por razões técnicas e ambientais, o lodo gerado no tratamento de águas para abastecimento público deve ser adequadamente tratado antes de ser disposto no meio ambiente. Uma alternativa é a disposição do lodo de ETA em ETE, o que dispensa a implantação da linha de tratamento do lodo na ETA. O objetivo deste trabalho foi estudar os impactos ocorridos na ETE ABC, estação de lodos ativados convencional operada pela SABESP, devido ao recebimento do lodo da ETA Rio Grande. Trata-se de caso particular, pois envolve instalações reais, e pelo fato de a ETA apresentar vazão próxima de três vezes a vazão da ETE (vazão de lodo corresponde a 0,1% da vazão da ETE). Os dados utilizados incluem variáveis de qualidade do efluente (DBO, DQO, SST, SSV, nitrogênio amoniacal e total, fósforo e ferro) e do lodo (sólidos), e parâmetros operacionais das unidades da ETE (vazões, taxas de aplicação superficial e de sólidos, idade do lodo, tempo de detenção, entre outros). Foi possível analisar o processo de tratamento na ETE e comparar seu desempenho entre dois períodos: controle (anos de 2005 e 2006) e com lodo (janeiro de 2007 a março de 2008). Nestes períodos, a ETE operou com 50% de sua capacidade (taxas de aplicação abaixo dos valores de projeto), idade do lodo de 4 dias e taxa de reciclo em torno de 80%. No período com lodo, as variáveis que apresentaram maior aumento de concentração no esgoto afluente foram SST, SSV, fósforo e ferro; o lodo da ETA contribuiu para maiores eficiências de tratamento da fase líquida na ETE, uma vez que houve a manutenção da qualidade do efluente final, nos níveis exigidos pela legislação, mesmo com o aumento das concentrações afluentes. Este aumento de eficiência foi mais acentuado para o fósforo (de 52% para 88%), e maior no tratamento primário, com variações nos parâmetros operacionais que não influíram negativamente no desempenho das unidades. No tratamento de lodo, o maior impacto causado foi o aumento na produção final de lodo (de 50 t/d para 76 t/d). Tais conclusões são então favoráveis ao lançamento de lodos de ETA convencional em ETE de lodos ativados convencional, mesmo nos casos em que a vazão tratada na ETA exceda em muito a vazão da ETE.<br>For technical and environmental reasons, sludge from water treatment plants should be properly treated before being discharged into the environment. An emerging practice is the disposal of such sludge in WWTP, an alternative that does not require the installation of sludge treatment facilities in the WTP. The main purpose of this research was to study the impacts at the ABC WWTP, an activated sludge process facility operated by SABESP and located in São Paulo, Brazil, due to receiving sludge from the Rio Grande WTP, also located in the same region. It is a particular case due to the fact that the WTP provides a flow of three times the flow treated in the WWTP (sludge flow is 0,1% of WWTP flow). The used data include effluent quality variables (BOD, COD, TSS, VSS, ammonia and total nitrogen, phosphorus and iron), sludge (solids) and WWTP units operational parameters (flow, surface and solid application rates, sludge retention time, hydraulic detention time, among others). It was possible to analyze the treatment process at the WWTP and compare its performance between two periods: control (years 2005 and 2006) and with sludge (from January 2007 to March 2008). In these periods, the WWTP worked with half of its capacity (all loading rates stayed below design values), sludge retention time of 4 days and recycle rate around 80%. In the with sludge period, the quality variables with the highest inflow concentration increase were TSS, VSS, phosphorus and iron. During the same period, the WTP sludge contributed to greater efficiencies in the WWTP treatment process, since the effluent quality was maintained under levels legally required, even with the increase of influent concentrations. This fact is mostly evident in the case of phosphorus (from 52% to 88%), and higher in primary treatment, with changes in operational parameters that did not adversely affect the units performances. In solid phase treatment, the most important impact was the increase in final sludge production (from 50 t/d to 76 t/d). These conclusions are then favorable to the disposal of sludge from conventional WTP in an activated sludge WWTP, even in cases in which the flow treated in the WTP far exceeds the WWTP flow.
APA, Harvard, Vancouver, ISO, and other styles
42

Soares, Manoel Barbosa. "Avaliação dos desreguladores endócrinos nas estações de tratamentos de esgotos e água." Universidade Federal de Goiás, 2016. http://repositorio.bc.ufg.br/tede/handle/tede/6055.

Full text
Abstract:
Submitted by Jaqueline Silva (jtas29@gmail.com) on 2016-08-31T16:48:26Z No. of bitstreams: 2 Dissertação - Manoel Barbosa Soares - 2016.pdf: 4279565 bytes, checksum: 89bf14a593b4bb1bf61e9c7e0becb0c2 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)<br>Approved for entry into archive by Jaqueline Silva (jtas29@gmail.com) on 2016-08-31T16:49:50Z (GMT) No. of bitstreams: 2 Dissertação - Manoel Barbosa Soares - 2016.pdf: 4279565 bytes, checksum: 89bf14a593b4bb1bf61e9c7e0becb0c2 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)<br>Made available in DSpace on 2016-08-31T16:49:51Z (GMT). No. of bitstreams: 2 Dissertação - Manoel Barbosa Soares - 2016.pdf: 4279565 bytes, checksum: 89bf14a593b4bb1bf61e9c7e0becb0c2 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2016-03-04<br>The toxicology of endocrine disruptors (ED), known as micro-pollutants, disposed in the environment through urine or excrements may cause physiological changes in aquatic living things. Therefore, it was aimed to evaluate the 17β – estradiol (E2) and progesterone and measure the quality of the wastewaters from the effluent of some Sewage Treatment Plants (STP’s) as of potable water in the Water Treatment Plant (WTP), located in Goiânia – GO, through the physical and chemical parameters, such as: Potential Hydrogen (PH), Temperature (T), Electric Conductivity (EC), Turbidity, Total Dissolved Solids (TDS), Salinity, Dissolved Oxygen (DO), Total Organic Nitrogen, Chemical Oxygen Demand (COD) and Biochemical Oxygen Demand (BOD). The quantization of endocrine disruptors was obtained through direct and competitive ELISA’s method, and all physical-chemical parameters were determined based on the APHA's Manual (2012). The effluent samples were collected at three distinct points: affluent (raw sewage), confluence of the effluent to the river (CER) and downstream of the release in STP’s Hélio Seixo de Brito (HSB), Samambaia (S) and Parque Atheneu (PA), while the samples of potable water were collected at two different points: in the capture of João Leite’s stream and after the water treatment in the WTP Jaime Câmara (JC). Through the physical-chemical parameters evaluated in the STP’s , the Turbidity , both DO and BOD, do not agree with the standards of CONAMA 357/05 and 430/11, which means that a lot of organic and inorganic matter are being dumped into the Meia Ponte River without treatment. In relation to the JC’s WTP, the same physical-chemical parameters are in accordance with the Decree No. 2,914 / 11 from the Ministry of Health, which deals with drinking water quality. The measured values for the E2 in the STP’s ranged in the rainy season around 53, 7 to 178, 24 ng/L and 45, 8 to 275, 0 ng/L in the dry season. In contrast with the progesterone in the same place where the values ranged from 69, 34 to 97, 54 ng / L in the rainy season from 60, 2 to 603, 8 ng / L in the dry season. While in the Meia Ponte River these values to the E2 ranged between 2,04 to 31,62 ng / L in the rainy season from 6,02 to 72,44 ng / L in the dry season and in relation to progesterone 4,35 to 52,48 ng / L in the rainy season 6,6 to 218,25 ng / L in the dry season. At João Leite’s stream, where is made the abstraction of the water for treatment, both in the rainy and drought seasons, E2 values were found 2,13 and 4,89 ng / L and progesterone 5,37 and 6,76 ng / L, however, the treated water that leaves the ETA, it was found in it values of E2 1,81 ng / L and 2,51 ng / L and progesterone 4,78 ng / L and 4,67 ng / L during the rainy and dry seasons, respectively. This search concludes that the biological method ELISA was efficient for the quantification of the studied hormones, and the values found for both the E2 and progesterone to the STP’s and ETA was xvii greater than 1.0 ng / L, and according to the literature these values are able to cause physiological damage in aquatic species.<br>A toxicologia dos desreguladores endócrinos (DE), conhecidos como micropoluentes, eliminados no meio ambiente através da urina ou fezes, causam alterações fisiológicas em seres vivos aquáticos. Assim, objetivou-se neste estudo avaliar os hormônios 17β-estradiol (E2) e progesterona, e medir a qualidade das águas residuais dos efluentes de algumas Estações de Tratamento de Esgotos (ETEs) e de água potável da Estação de Tratamento de água (ETA) localizados em Goiânia-GO, por meios dos parâmetros físico-químicos como: Potencial Hidrogeniônico (pH), Temperatura (T), Condutividade Elétrica (CE), Turbidez, Sólidos Totais Dissolvidos (TDS), Salinidade, Oxigênio Dissolvidos (OD), Nitrogênio Orgânico Total, Demanda Química de Oxigênio (DQO) e Demanda Bioquímica de Oxigênio (DBO). A quantificação dos desreguladores endócrinos foi realizada através do método de ELISA direto e competitivo e, todos os parâmetros físico químicos foram determinados com base no Manual da APHA (2012). As amostras dos efluentes foram coletadas em três pontos distintos: afluentes (esgoto bruto), confluência do efluente com o rio (CER) e jusante do lançamento nas ETEs Hélio Seixo de Britto (HSB), Samambaia (S) e Parque Ateneu (PA), enquanto que as amostras para avaliar a potabilidade da água em dois pontos diferentes: na captação do Ribeirão João Leite e após o tratamento da água na ETA Jaime Câmara (JC). Dos parâmetros físico químicos avaliados, nas ETEs, a Turbidez, o OD e a DBO, estão em desacordo com as normas do CONAMA 357/05 e 430/11, o que significa que estão sendo despejados no rio Meia Ponte grande quantidade de matéria orgânica e inorgânica sem tratamento. Em relação à ETA JC os parâmetros físico-químicos estão em conformidade com a portaria nº 2.914/11, do Ministério da Saúde, que trata da potabilidade da água. Os valores obtidos para o E2 nas ETEs variaram no período chuvoso entre 53,7 a 178,24 ng/L e no período de estiagem entre 45,8 a 275,0 ng/L. Em contrapartida, em relação a progesterona no mesmo local, esses valores variaram entre 69,34 a 97,54 ng/L no período chuvoso e 60,2 a 603,8 ng/L no período de estiagem. No rio Meia Ponte esses valores para o E2 estiveram entre 2,04 a 31,62 ng/L no período chuvoso e 6,02 a 72,44 ng/L no período de estiagem, e com relação à progesterona, os valores variaram de 4,35 a 52,48 ng/L no período chuvoso e 6,6 a 218,25 ng/L no período de estiagem. No ribeirão João Leite onde é feito a captação de água para tratamento, tanto no período de chuva como estiagem, foram encontrados valores de E2 de 2,13 a 4,89 ng/L, e progesterona de 5,37 e 6,76 ng/L. Na água tratada, que sai da ETA, verificaram-se valores de 1,81 ng/L e 2,51 ng/L, e da progesterona de 4,78 ng/L e 4,67 ng/L nos períodos de chuva e estiagem, respectivamente. Dessa pesquisa se conclui que o método biológico ELISA, foi eficiente para quantificação dos hormônios estudados, e os valores encontrados tanto para o E2 como para a progesterona nas ETEs e ETA foi maior que 1,0 ng/L e segunxv do a literatura esses valores são capazes de provocar danos fisiológicos em espécies aquáticas.
APA, Harvard, Vancouver, ISO, and other styles
43

Reis, Jose Roberto Bezerra dos. "Estudo de reuso e reciclagem de agua de lavagem de filtro rapido de estação de tratamento de agua, em sistema de ciclo fechado, independente." [s.n.], 2009. http://repositorio.unicamp.br/jspui/handle/REPOSIP/258655.

Full text
Abstract:
Orientador: Ruben Bresaola Junior<br>Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo<br>Made available in DSpace on 2018-08-14T17:21:03Z (GMT). No. of bitstreams: 1 Reis_JoseRobertoBezerrados_M.pdf: 4806731 bytes, checksum: f4634921271dbf74dd3233925df387a5 (MD5) Previous issue date: 2009<br>Resumo: O projeto foi desenvolvido visando estudar o tratamento e o reuso da água de lavagem de filtro para reciclagem nesta função, dentro de um circuito fechado, em sistema independente das atividades de produção de uma estação de tratamento de água de abastecimento. O sistema foi dotado de unidade de mistura de polímero, pré-filtro de pedregulho e filtro de dupla camada (F3), semelhante aos usados na estação de tratamento de água. O pré-filtro foi retirado do sistema porque não forneceu a eficiência esperada. Com esta disposição foi monitorado o número de vezes que a água obtida poderia ser reutilizada sem influir na qualidade da água de início de filtração do filtro piloto F1, o que mostrou ser maior ou igual cinco vezes. A perda da água de lavagem no sistema foi de 0,13%, bastante significativo perante os valores costumeiros de 2 a 5%. O sistema operou sempre com partículas floculentas, nunca com partículas coloidais.<br>Abstract: The project was developed with the aim of studying the treatment and the reuse of rapid filter backwash water for recycling in this role, within a closed cycle, under system independent of production activities of a water treatment plant. The system was assembled with a polymer blending unit, a gravel preliminary upflow filter and a dual layer filter(F3), similar to those used in the water treatment plant. The pre-filter was withdrawn because it did not provided the expected efficiency. With this provision, it was monitored the number of times that water obtained could be reused without affecting the quality of water filtration top of the filter F1 which proved to be greater or equal to five times. The loss of filter backwash water in the system was 0,13%, quite significant when compared to the usual 2 to 5%. The system always worked with flocculent particles, not with colloidal particles.<br>Mestrado<br>Saneamento e Ambiente<br>Mestre em Engenharia Civil
APA, Harvard, Vancouver, ISO, and other styles
44

Machado, Irineu Afonso. "Tratamento terciário de efluentes de estações de tratamento por lodo ativado para fins de reuso como água de reposição em torres de resfriamento." reponame:Repositório Institucional da FIOCRUZ, 2006. https://www.arca.fiocruz.br/handle/icict/4855.

Full text
Abstract:
Made available in DSpace on 2012-09-06T01:11:29Z (GMT). No. of bitstreams: 2 license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) 877.pdf: 3274722 bytes, checksum: 8d3241baa6c0846580f798aa87b9caa5 (MD5) Previous issue date: 2006<br>No presente trabalho são apresentados estudos do tratamento terciário de efluentes de estações de tratamento de esgotos domésticos por processo de lodo ativado, variação aeração prolongada, com objetivo de reuso na alimentação em torres de resfriamento de circuitos semi-abertos, substituindo na recomposição, águas potáveis fornecidas por empresas de saneamento. Neste sentido foi proposta a aplicação de tratamento terciário por clarificação físico-química: coagulação, floculação e decantação, filtração e desinfecção por cloro, de forma a obter água com qualidade compatível para utilização em torres de resfriamento de acordo com as normas vigentes. A metodologia utilizada para a obtenção dos resultados foi experimental, onde construiu-se uma unidade piloto conforme a proposta e operou-se o processo com três efluentes de estações de tratamento por aeração prolongada com idades de lodo e níveis de nitrificação diferentes. Todos os experimentos foram precedidos por exames laboratoriais de jarteste utilizando-se sulfato de alumínio, cloreto férrico e policloreto de alumínio como coagulantes, isoladamente ou com auxiliares de floculação da classe catiônica ou aniônica. (...) Verificou-se, também, que neste processo terciário não há redução da concentração dos sólidos dissolvidos, sendo sua aplicação limitada a águas servidas de baixa salinidade, pois caso contrário pode inviabilizá-lo economicamente devido aos baixos ciclos de concentração que deverão ser mantidos nos circuitos de resfriamento com recirculação de água.
APA, Harvard, Vancouver, ISO, and other styles
45

Cruz, Fabíola Greice. "Presença de trihalometanos e qualidade sanitária da água nas estações de tratamento e reservatórios domiciliares nos municípios de Araraquara e Bariri/SP /." Araraquara : [s.n.], 2012. http://hdl.handle.net/11449/100944.

Full text
Abstract:
Orientador: Adalberto Farache Filho<br>Banca: Wellington Cyro de Almeida Leite<br>Banca: João Bosco Faria<br>Resumo: A estação de tratamento de água (ETA) tem por finalidade primaria torná-la potável para o consumo humano. A principal etapa de um tratamento é a desinfecção, que elimina os organismos patogênicos presentes na água que oferecem riscos à saúde do consumidor. Um efeito indesejado da desinfecção é a interação do cloro com a matéria orgânica natural (MON) presente na água de mananciais, formando uma gama de produtos químicos secundários chamados de subprodutos da desinfecção (SPD). Mais de 700 SPD já foram relatados, sendo o grupo dos trihalometanos (THMs) formados em maior proporção. Os quatro principais compostos desse grupo são: Clorofórmio, Bromodiclorometano, Dibromoclorometano e Bromofórmio, referidos na literatura como trihalomentanos totais (THMt). A preocupação com a formação dos THMt se dá pelo fato de que várias pesquisas realizadas mostraram a correlação positiva principalmente do câncer de bexiga e intestino grosso com a água que contêm esses compostos. No Brasil, o Ministério da Saúde recomenda um teor máximo de THMt de 100 µg/L em água potável. Este trabalho teve como objetivo identificar a presença de THMt e analisar a qualidade sanitária da água das estações de tratamento até os reservatórios domiciliares nas cidades de Araraquara e Bariri/SP, e verificar, se essas atendem ao padrão de potabilidade exigido pela Portaria nº 2.914 de 12 de Dezembro de 2011. A qualidade da água da ETA de Araraquara/SP pode ser considerada satisfatória, necessitando de uma maior atenção em relação à quantidade de cloro residual livre e a contagem de bactérias heterotróficas. Em Bariri/SP, foram encontrados vários pontos em desacordo com a legislação vigente... (Resumo completo, clicar acesso eletrônico abaixo)<br>Abstract: The water treatment stations (WTPs) has the primary purpose make it potable for human consumption. The principal stage of treatment is disinfection, which eliminates the pathogenic organisms present in the water that offer risks to consumer health. An unwanted effect of disinfection is the interaction of chlorine with natural organic matter (NOM) present in the water sources, forming a range of secondary chemicals called disinfection by-products (DBP). Over 600 SPD have been reported, and the group of trihalomethanes (THMs) formed in major proportion. The four major compounds of this group are: Chloroform, bromodichloromethane, and dibromochloromethane Bromoform, referred to in the literature as total trihalomentanos (THMt). The worry with the formation of THMt occurs by the fact that several surveys have shown a positive correlation especially bladder cancer and large intestine with water containing these compounds. In Brazil, the Ministry of Health recommends a maximum THMt of 100 µg / L in drinking water. This study aimed to identify the presence of THMt and analyze the sanitary quality of water in WTPs until reservoirs home of cities Araraquara and Bariri / SP, and check if they meet the potability standards. The water quality of the WTS Araraquara/SP, can be considered satisfactory, needing greater attention in relation to the amount of chlorine and heterotrophic bacterial count. In Bariri/SP, several points were found at variance with the law, mostly free residual chlorine, turbidity and total coliforms, requiring... (Complete abstract click electronic access below)<br>Mestre
APA, Harvard, Vancouver, ISO, and other styles
46

Barbosa, Rosana Maria. "Avaliação do impacto de lodos de estações de tratamento de água à biota aquática através de estudos ecotoxicológicos." Universidade de São Paulo, 2000. http://www.teses.usp.br/teses/disponiveis/18/18139/tde-16072018-150318/.

Full text
Abstract:
Lodos de duas Estações de Tratamento de Água (ETA) que utilizam cloreto férrico (ETA-Paiol-ETA-1) e sulfato de alumínio (ETA-SAAE-ETA-2) como coagulantes, foram caracterizados físico-quimicamente em duas estações do ano (chuvosa e seca) e submetidos a testes de toxicidade aguda com microcrustáceos (Daphnia similis), quironomídeos (Chironomus xanthus) e peixes (Hyphessobrycon eques) e de toxicidade crônica com microcrustáceos (D. similis). Observou-se ainda os efeitos destes lodos na comunidade bentônica dos corpos d\'água que recebem os lançamentos das ETAs. Os efeitos dos lodos nos testes de toxicidade aguda foram observados em relação a mortalidade, e, quanto aos testes de toxicidade crônica, observou-se os efeitos na reprodução (número de neonatas) e na mortalidade. Em geral, os lodos das duas ETAs não causaram toxicidade aguda aos organismos-teste, ocorrendo apenas indícios de toxicidade. O lodo da ETA que utilizava cloreto férrico causou toxicidade crônica, que foi observada na reprodução (baixo número de neonatas) e na alta taxa de mortalidade, enquanto que o lodo da ETA que utilizava sulfato de alumínio causou toxicidade crônica evidenciada apenas em relação a reprodução. Os lodos causaram efeitos adversos à fauna bentônica, evidenciados pela predominância de Diptera nos pontos de lançamento das ETAs nos corpos receptores. Constatou-se ainda a variação temporal na caracterização dos lodos em relação aos parâmetros: pH, turbidez, série de sólidos, nutrientes (N e P) e metais (AI, Mn e Fe), sendo que estes, juntamente com a DQO, foram identificados como os principais parâmetros que aumentam a degradação dos corpos receptores que recebem os lançamentos dos efluentes das ETAs. Portanto, a disposição \"in natura\" dos efluentes das ETAs prejudica à biota aquática e compromete a qualidade da água e do sedimento dos corpos receptores.<br>Sludges from two water treatment plants, which use ferric chloride (ETA-Paiol-ETA-1) and alum (ETA-SAAE-ETA-2) as coagulants were characterized physicall y and chemically at two seasons (wet and dry). The sludge was subjected to acute toxicity tests to cladoceran (Daphnis similis), midges (Chironomus xanthus) and fishes (Hyphessobrycon eques) and chronic toxicity tests using clacloceran (D. similis). It also was observed the impact of discharged sludge on benthic communities in surface waters at two water treatment plants. Acute toxicity tests evaluated sludge effects on mortality, while chronic toxicity tests assessed effects on reproduction and mortality. In general, sludges from two water treatment plants did not show acute toxicity on organisms-test, only toxicity traces. Ferric chloride sludge showed chronic toxicity on lower brood production and high mortality rate. Alum sludge showed chronic toxicity only on brood production. Sludges from water treatment plants caused detrimental effects to benthic macroinvertebrate communities. This effect was determined by Diptera predominance at bodies receiving discharge from water treatment plants. The turbidity, solids series, nutrients (N and P) and metals (Al, Mn and Fe) in the sludge vary when experiments are carried out in the dry and wet season. Together with COD, there were the main parameters that cause the increase in degradation of bodies receiving discharge from water treatment plants. Thus the disposal of \"in natura\" effluents from water treatment plants damages aquatic biota and affects receiving bodies water and sediment quality.
APA, Harvard, Vancouver, ISO, and other styles
47

Prim, Elivete Carmem Clemente. "Utilização de lodo de estações de tratamento de água e esgoto como material de cobertura de aterro sanitário." reponame:Repositório Institucional da UFSC, 2011. http://repositorio.ufsc.br/handle/123456789/103375.

Full text
Abstract:
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Ambiental, Florianópolis, 2011<br>Made available in DSpace on 2013-07-16T04:22:53Z (GMT). No. of bitstreams: 1 317425.pdf: 5311695 bytes, checksum: a0a52eef432ea37336bb66824e150dad (MD5)<br>Os aterros sanitários são obras que movimentam grandes volumes de terra contribuindo, muitas vezes, para a degradação ambiental, pois utilizam solos provenientes de jazidas naturais. Por outro lado, o gerenciamento dos lodos gerados nas estações de tratamento de água e de esgoto ainda são um grande desafio para as empresas de saneamento. Desta forma, nesta pesquisa, procurou-se avaliar-se o potencial de lodos de estação de tratamento de água e de esgoto a fim de serem aproveitados como material de cobertura de aterros sanitários. A metodologia experimental da pesquisa envolveu a caracterização dos lodos de ETE e ETA utilizados e de uma amostra de solo argiloso usado em cobertura de aterro; a estabilização alcalina como forma de higienizar o lodo antes de torná-lo um produto de cobertura de aterro sanitário, testando diferentes percentuais de mistura de lodo/alcalinizante; posteriormente realizou-se uma avaliação e adequação do ponto de vista geotécnico das misturas viáveis ambientalmente. Finalmente, o material selecionado foi testado em um piloto que simulou uma célula de aterro, a fim de verificar a influência na composição do liquido percolado gerado. Os resultados mostraram que ambientalmente é viável se higienizar o lodo com teores de cal abaixo do que se recomenda para uso como biossólidos. Geotecnicamente, o lodo de ETE e ETA higienizados com 5, 10 e 15% de alcalinizante, não alcança as características necessárias, mas que, adicionando solo argiloso na mistura o comportamento geotécnico assemelha-se aos de um solo natural usado em cobertura de aterro. O uso como material de cobertura intermediaria na proporção de LETA:LETE:CaO:Solo de 0,425:0,425:0,15:1, não altera significativamente a composição do percolado gerado no aterro sanitário. Também foi comprovada sua viabilidade econômica do ponto de vista do empreendedor de aterros.<br><br>Abstract : The landfill sealing systems are used in order to protect the environment from the wastes landfilled. Those are means that move large amounts of material contributing to the environmental degradation. It occurs because natural deposits of soil are required. On the other hand, the management of sludge from water and wastewater treatment plants (WTP and WWTP) is still a great challenge for sanitations companies because it involves activities of high complexity and high costs as well. Thus, this research proposes to evaluate the potential of using sewage slugde and water sludge as cover material for landfills. In this research it was considered the regulations of using the biosolids in agriculture and in landfills. The methodology of the research involved four steps. The first step: the characterization of WTP sludge, WWTP sludge, and clay soil used in landfill cover. The second step: use the alkaline stabilization as a way to sanitize the sludge before making it a landfill cover product by testing different percentages of sludge / alkaline. The third step: mixtures environmentally viable were evaluated from geotechnical point of view before and after blending with natural soil. Finally, the selected material was tested in a pilot that simulates a landfill cell in order to verify its influence in leachate quality. The results showed that is environmentally feasible to sanitize the sludge with low lime levels, different of literature#s recommendation about biosolids. Geotechnically, the WTP and WWTP sludge stabilized with 5, 10 and 15% CaO are not suitable, but when natural soil were blended, the geotechnical behavior were similar to a natural soil used as landfill cover. The use mixture of intermediate cover material in the proportion of WTP:WWTP:CaO:Soil, respectively, 0,425:0,425:0,15:1, does not significantly change the composition of the leachate from a landfill. It was also proven their economic viability from the standpoint of the entrepreneur landfill.
APA, Harvard, Vancouver, ISO, and other styles
48

Guimarães, Gustavo Costa. "Estudo do adensamento e desidratação dos resíduos gerados na ETA-Brasília." reponame:Repositório Institucional da UnB, 2007. http://repositorio.unb.br/handle/10482/1369.

Full text
Abstract:
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2007.<br>Submitted by Luis Felipe Souza (luis_felas@globo.com) on 2009-01-07T12:14:46Z No. of bitstreams: 1 Dissertacao_2007_GustavoGuimaraes.pdf: 4183016 bytes, checksum: 7c61ae67e75c158534feef02df523212 (MD5)<br>Approved for entry into archive by Georgia Fernandes(georgia@bce.unb.br) on 2009-02-27T15:39:08Z (GMT) No. of bitstreams: 1 Dissertacao_2007_GustavoGuimaraes.pdf: 4183016 bytes, checksum: 7c61ae67e75c158534feef02df523212 (MD5)<br>Made available in DSpace on 2009-02-27T15:39:08Z (GMT). No. of bitstreams: 1 Dissertacao_2007_GustavoGuimaraes.pdf: 4183016 bytes, checksum: 7c61ae67e75c158534feef02df523212 (MD5)<br>O presente trabalho enfoca o adensamento e desidratação dos resíduos da ETA-Brasília, importante unidade operacional do sistema de abastecimento de água do Distrito Federal. A ETA-Brasília está passando por intervenções de reforma e ampliação, e estudos anteriores indicaram que o tratamento dos resíduos proposto para essa estação que inclui a desidratação por centrífuga, provavelmente apresentará resultados inferiores aos indicados no projeto, em termos de concentração de sólidos na torta. Como conseqüência, a ETA-Brasília apresentará maiores custos operacionais para desidratação dos resíduos produzidos e para transporte da torta gerada, além de eventuais problemas ambientais associados à alternativa selecionada para destinação final. Duas hipóteses foram levantadas para explicar a baixa desidratabilidade observada na desidratação por centrífuga, e são objeto de avaliação desse trabalho. A primeira seria a influência da presença de algas na água bruta, que emprestam características orgânicas ao lodo. A outra hipótese é relacionada à possibilidade dos lodos flotados reterem parte das microbolhas da flotação em sua estrutura, dificultando a etapa de desidratação. Dessa forma, a metodologia experimental do presente trabalho permitiu comparar a desidratação entre lodos produzidos pelo adensamento da água de lavagem da ETA-Brasília, por flotação e sedimentação, com o de outra estação de tratamento de água (ETA-Descoberto), abastecida por manancial com água bruta de diferentes características. Os experimentos de adensamento foram realizados em instalação piloto, localizada na ETA-Brasília, e os de desidratação, tanto por centrifugação quanto por filtração forçada, em escala de bancada. Os resultados obtidos mostraram não haver influência importante do processo de adensamento na desidratabilidade dos lodos de ETAs, sugerindo que a incorporação de microbolhas de ar ao lodo não é o fator que determina a baixa eficiência da centrifugação. Em relação à influência das características da água bruta, verificou-se que a água bruta que alimenta a ETA-Brasília, de caráter orgânico devido à presença de algas, produziu resíduos no tratamento de água também com características orgânicas, e essas características foram determinantes na desidratabilidade dos lodos, levando a teores de sólidos na torta da ordem de 10%, bastante inferiores aos obtidos a partir dos resíduos da ETA-Descoberto, freqüentemente acima de 30%. A avaliação preliminar utilizando a técnica de descongelamento e descongelamento indicou que a baixa desidratabilidade dos resíduos da ETA-Brasília pode estar relacionada à distribuição de água na estrutura interna do floco, que é determinada nos primeiros estágios do tratamento de água bruta, recomendando-se estudar a coagulação e floculação como forma de se obter lodos com melhores características de desidratabilidade. _______________________________________________________________________________ ABSTRACT<br>The present work focuses the thickening and dewatering of residues from the Brasilia Water Treatment Plant (WTP), an important operational unit of the water supply system in the Federal District, Brazil. Brasília WTP is enlarging and undergoing improvements, and previous studies have indicated that the treatment of the residues which includes centrifuge dewatering, will present inferior results to those indicated in the project, in terms of cake solid content. As a consequence, Brasília WTP will have greater operational costs for dewatering of the produced residues and the transport of the generated cake, beyond the eventual environmental problems associated with the alternative final disposal. Two hypotheses were raised to explain the low dewaterability observed in the centrifugal dewatering, and are objectives of evaluation in this work. The first one is the presence of algae in raw water, which gives the sludge organic characteristics. The second hypothesis is related to the possibility of sludge retaining part of the micro-bubbles in its structure, hampering the dewatering phase and resulting in a cake with a low solids content. The experimental methodology of the present work compared the centrifugal dewatering between flotation and sedimentation thickened sludge, using backwash water from Brasilia WTP, with another WTP plant (Descoberto WTP), supplied by reservoir with different raw water characteristics. Thickening experiments were carried out in a pilot plant located at Brasilia WTP. Dewatering tests were carried in a bench scale, as much for centrifugation as for press filters. The results obtained in the present work showed that there was no important difference in the thickening process in sludge WTP, suggesting that the incorporation of micro-bubbles of air in the sludge is not the factor that determines the low efficiency of centrifuge dewatering. In relation to the influence of the raw water characteristics, it was verified that the raw water that supplies Brasilia WTP, with an organic character due to algal presence, also produced residues in the water treatment with organic characteristics, and these characteristics were determinative in the sludge dewatering, leading to a cake solids content in the order of 10%, very inferior to those obtained from the residues of Descoberto WTP, frequently above 30%. The preliminary evaluation using the freeze-thaw technique indicated that the low dewaterability of the residues of Brasilia WTP can be related to the water distribution in the internal structure of the floc, that is determined in the initial steps of raw water treatment, and further studies in the coagulation and flocculation as form of getting sludges with better dewaterability characteristics are recommended.
APA, Harvard, Vancouver, ISO, and other styles
49

Souza, Cássia Cabral e. "Aplicação dos ensaios Salmonella/microssoma e MTT para avaliação da mutagenicidade e citotoxicidade de águas submetidas à cloração e fotocatálise." reponame:Repositório Institucional da UFOP, 2014. http://www.repositorio.ufop.br/handle/123456789/3680.

Full text
Abstract:
Programa de Pós-Graduação em Engenharia Ambiental. PROÁGUA, Pró-Reitoria de Pesquisa e Pós Graduação, Universidade Federal de Ouro Preto.<br>Submitted by Oliveira Flávia (flavia@sisbin.ufop.br) on 2014-10-15T20:21:10Z No. of bitstreams: 2 license_rdf: 22190 bytes, checksum: 19e8a2b57ef43c09f4d7071d2153c97d (MD5) DISSERTACAO_AplicaçãoEnsaiosSalmonella.pdf: 1814909 bytes, checksum: 7086c2b9cbdfa484976fc4501ff4fd42 (MD5)<br>Approved for entry into archive by Gracilene Carvalho (gracilene@sisbin.ufop.br) on 2014-11-04T16:50:26Z (GMT) No. of bitstreams: 2 license_rdf: 22190 bytes, checksum: 19e8a2b57ef43c09f4d7071d2153c97d (MD5) DISSERTACAO_AplicaçãoEnsaiosSalmonella.pdf: 1814909 bytes, checksum: 7086c2b9cbdfa484976fc4501ff4fd42 (MD5)<br>Made available in DSpace on 2014-11-04T16:50:26Z (GMT). No. of bitstreams: 2 license_rdf: 22190 bytes, checksum: 19e8a2b57ef43c09f4d7071d2153c97d (MD5) DISSERTACAO_AplicaçãoEnsaiosSalmonella.pdf: 1814909 bytes, checksum: 7086c2b9cbdfa484976fc4501ff4fd42 (MD5) Previous issue date: 2014<br>Diversas classes de fármacos têm sido detectadas no ambiente em baixas concentrações (ng/L a μg/L), e mais recentemente em amostras de água tratada. A maioria das ETAs no Brasil opera com tratamento convencional da água sem a implantação de etapas específicas para a remoção de microcontaminantes. Quando fármacos entram em contato com o cloro, como o hipoclorito de sódio, na desinfecção podem ser oxidados e transformados em subprodutos com estrutura química e potencial tóxico algumas vezes desconhecidos. Os Processos Oxidativos Avançados (POA) como a fotocatálise com TiO2/UV-C têm sido pesquisados como alternativa à cloração para aumentar a eficiência de remoção de tais compostos. Neste trabalho foi padronizada e implementada a técnica Salmonella/microssoma (teste de Ames) para avaliação da mutagenicidade e aplicado o ensaio colorimétrico do MTT em células HepG2 para verificar a citotoxicidade dos fármacos captopril (CPT), diclofenaco (DCF) e sulfametoxazol (SMX) e dos seus possíveis subprodutos formados após cloração e fotocatálise com TiO2/UV-C. As concentrações dos fármacos testadas foram 1, 0,75, 0,50, 0,25 e 0,01 mg/L e os tempos de contato de 5 e 30 min para a cloração e 120 min para a fotocatálise. A dose de cloro foi 1mg/L para o DCF e SMX e para o CPT 10 mg/L. A concentração de TiO2 foi 120 mg/L. Os resultados do ensaio de mutagenicidade foram avaliados adotando três variáveis para interpretação dos dados (ANOVA, relação dose-resposta e razão de mutagenicidade). Com base nestas variáveis, os três fármacos e suas amostras cloradas e após fotocatálise não induziram mutações do tipo deslocamento do quadro de leitura e substituição dos pares de base nas cepas TA98 e TA100 da bactéria S. typhimurium com (+S9) e sem (-S9) metabolização (mistura S9) nas doses testadas. Estes resultados estão de acordo com os dos testes de viabilidade celular por MTT em que os tratamentos da água com cloro e TiO2/UV-C não causaram efeito tóxico para os fármacos CPT e DCF. Após o tratamento da água com estes fármacos observou-se um aumento da viabilidade celular sugerindo que ambos não induzem ação tóxica às células nas doses investigadas (0,8, 20, 40, 60, 80 ng/poço). Os resultados da citotoxicidade do SMX foram inconclusivos uma vez que apenas a dose intermediária (40 ng/poço) mostrou diminuição da viabilidade celular, o que indicaria um possível efeito tóxico após o tratamento com cloro. ________________________________________________________________________<br>ABSTRACT: Several classes of drugs have been detected in the environment at low concentrations (ng/L a μg/L), and more recently in samples of treated water. Most Brazilian Water Treatment Plant (WTP) operates with conventional water treatment without the deployment of specific steps for removing microcontaminants. When drugs come into contact with chlorine as sodium hypochlorite for disinfection, they can be oxidized and transformed into products wich sometimes have unknown structure and toxic potential. The Advanced Oxidative Processes (AOP) as TiO2/UV-C photocatalysis have been tested by different research groups to increase the efficiency of removal of such compounds. For this work was standardized and implemented Salmonella / microsome assay (Ames test) for evaluation of mutagenicity and applied the MTT colorimetric assay in HepG2 cells to verify the cytotoxicity of drugs captopril (CPT), diclofenac (DCF) and sulfamethoxazole (SMX) and the possible products formed after chlorination and photocatalysis with TiO2/UV-C. The concentrations of the drugs tested were 1, 0,75, 0,50, 0,25 and 0,01 mg/L and contact time 5 and 30 min for chlorination and 120 min for photocatalysis. The dosage of chlorine was 1mg/L for DCF and SMX and for CPT was 10 mg/L. The concentration of TiO2 was 120 mg/L. The results of the mutagenicity test were evaluated taking three variables for the interpretation of the data (ANOVA, dose-response relationship and mutagenicity ratio). Based on this approach, drugs and their chlorinated samples and after photocatalysis did not induce frameshift and base-pair substitution mutations in TA98 and TA100 strains of S. typhimurium bacteria with (+S9) and without (-S9) metabolic activation system (mix S9) at the doses tested. These results are in agreement with tests of cell viability by MTT in the treatment of water with chlorine and TiO2/UV-C did not cause toxic effects to the cells for CPT and DCF drugs. After the water treatment with these drugs it was observed an increase in cell viability suggesting that both contaminant do not induce toxic effect to the cells at the doses investigated (0,8, 20, 40, 60, 80 ng/well). The results of the cytotoxicity of SMX were not conclusive since only the intermediate dose (40 ng/well) showed a decreased cell viability, which would indicate a possible toxic effect after treatment with chlorine.
APA, Harvard, Vancouver, ISO, and other styles
50

Costa, Jiulliano de Sousa. "ANÁLISE QUÍMICA DA ÁGUA NAS ESTAÇÕES DE TRATAMENTO DE ÁGUA (ETA s) DA REGIÃO METROPOLITANA DE GOIÂNIA-GO E SUA RELAÇÃO COM A SAÚDE." Pontifícia Universidade Católica de Goiás, 2010. http://localhost:8080/tede/handle/tede/3143.

Full text
Abstract:
Made available in DSpace on 2016-08-10T10:56:15Z (GMT). No. of bitstreams: 1 JIULLIANO DE SOUSA COSTA.pdf: 4621168 bytes, checksum: acf833331f3016e32ef47b29c97b04d7 (MD5) Previous issue date: 2010-06-30<br>Water is responsible for transporting minerals in the physiology of living beings, which makes human health dependent on its potability. As part of the work carried out by Company of Mineral Resources Research (Companhia de Pesquisas dos Recursos Minerais CPRM) in the Water Treatment Plants of the Goiás State, samples collected in 11 municipalities in the metropolitan region of Goiânia-GO were analyzed aiming at verifying the physical-chemical parameters and multielement composition of water (method ICP-OES and chromatography). The results obtained were compared to Brazilian and international standards of water quality and correlated with possible health problems that may be caused by excess or lack of some chemical elements present in living beings. Environmental alterations were identified in the municipality of Goianira-GO, with the presence of lead in the composition of the water that supplies the population. In Parque dos Girassóis, a neighborhood near the points where the water that supplies the municipality of Goianira-GO is collected, the presence of auto repair shops and junk yards was detected. These enterprises deal with car batteries and other products that contain lead in their composition and dispose of these materials directly into the soil. This causes the contamination of water and poses health risk to the local population.<br>A água é responsável pelo transporte dos minerais na fisiologia dos seres vivos, o que torna a saúde do homem dependente de sua potabilidade. Como parte do trabalho realizado pela Companhia de Pesquisas dos Recursos Minerais (CPRM) nas Estações de Tratamento de Água do Estado de Goiás, analisaram-se as amostras referentes a 11 municípios da região metropolitana de Goiânia-GO, com o objetivo de verificar os parâmetros físico-químicos e a composição multielementar da água (método ICP-OES e cromatografia). Os resultados obtidos foram comparados com os padrões brasileiros e internacionais de qualidade da água e correlacionados com possíveis problemas de saúde que podem ser provocados por excesso ou carência de alguns elementos químicos presentes no organismo dos seres vivos. Foram identificadas alterações ambientais no município de Goianira-GO, verificando-se a presença de chumbo na composição da água que abastece a população. No loteamento Parque dos Girassóis, próximo aos poços de captação de água que abastece o município de Goianira- GO, há a presença de oficinas mecânicas e ferros velhos. Esses estabelecimentos trabalham com baterias automotivas e outros produtos contendo chumbo em sua composição e lançam esses materiais diretamente no solo. Isso causa a contaminação da água e coloca em risco a saúde da população local.
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!

To the bibliography