Academic literature on the topic 'Facoemulsificação Com Implante de Lio'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Facoemulsificação Com Implante de Lio.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "Facoemulsificação Com Implante de Lio"

1

Pavan, P. T., J. J. T. Ranzani, M. F. Almeida, M. J. Mamprim, and C. V. S. Brandão. "Avaliação ultrassonográfica do bulbo ocular em cães submetidos à facoemulsificação com ou sem implante de lente intraocular." Arquivo Brasileiro de Medicina Veterinária e Zootecnia 66, no. 1 (February 2014): 121–28. http://dx.doi.org/10.1590/s0102-09352014000100018.

Full text
Abstract:
Este trabalho objetivou descrever e comparar as alterações ultrassonográficas encontradas em bulbos oculares de cães submetidos à facoemulsificação, com ou sem implante de lente intraocular (LIO), no intuito de auxiliar no diagnóstico de alterações decorrentes da cirurgia e do implante da LIO, bem como sua correspondência com alterações clínicas. Dezenove cães portadores de catarata (21 olhos) foram submetidos ao procedimento de facoemulsificação e avaliados no pós-operatório tardio, aos cinco anos de evolução. Constituíram-se três grupos experimentais: afácicos (CA), formados por 11 cães; pseudofácicos (PP), com implante de duas LIOs em piggyback (n=5); e pseudofácicos (PL), com implante de uma LIO veterinária (n=5). Após exame oftálmico, todos foram submetidos ao exame ultrassonográfico, sob anestesia tópica, com transdutor linear multifrequencial de 10MHz; adicionalmente foram avaliadas medidas biométricas dos bulbos do olho. As principais alterações observadas foram: luxação da LIO, descolamento de retina, hialose asteroide e degeneração vítrea. O exame ultrassonográfico mostrou-se como excelente ferramenta diagnóstica e possibilitou a confirmação e a classificação dessas alterações. Na biometria ocular, pelas medidas entre o corpo ciliar e a câmara vítrea, o implante em piggyback resultou em redução destas em relação aos demais procedimentos instituídos, não havendo diferença ente o comprimento axial e a câmara anterior.
APA, Harvard, Vancouver, ISO, and other styles
2

Rodrigues, Geórgia N., Rosana Maria O. Clark, José Joaquim T. Ranzani, Cláudia Valéria S. Brandão, Daniela N. Cremonini, Antonio Carlos L. Rodrigues, and Silvia Helena V. Perri. "Facoemulsificação em cães, com e sem implante de lente intra-ocular em piggyback: estudo clínico da inflamação pós-operatória." Pesquisa Veterinária Brasileira 30, no. 2 (February 2010): 103–7. http://dx.doi.org/10.1590/s0100-736x2010000200001.

Full text
Abstract:
A uveíte peri e pós-operatória é o maior problema da cirurgia para extração de catarata no cão, sendo considerada o fator mais importante para o sucesso cirúrgico, imediato e tardio. Diversos protocolos pré e pós-operatórios utilizando agentes anti-inflamatórios esteroidais e não-esteroidais têm sido empregados na tentativa de controle da uveíte cirurgicamente induzida. O objetivo do presente estudo foi avaliar a reação inflamatória pós-operatória, clinicamente e por meio da pressão intraocular (PIO), após a cirurgia de facoemulsificação para extração de catarata em cães, com e sem implante de lente intraocular (LIO) em piggyback. Empregaram-se, 25 cães portadores de catarata, subdivididos em dois grupos: G1 (com implante de LIO), G2 (sem implante de LIO). A técnica cirúrgica adotada foi a facoemulsificação bimanual unilateral. Avaliações clínicas e mensurações da PIO foram aferidas antes do procedimento cirúrgico (0) e nos tempos 3, 7, 14, 21, 28 e 60 dias após o ato cirúrgico. Cães do grupo G1 apresentaram sinais clínicos de uveíte visivelmente mais intensos, relativamente aos do G2. Entretanto, a PIO não demonstrou diferença significativa entre os dois grupos analisados, nem entre os olhos operados e os contralaterais. A utilização de duas LIOs humanas em piggyback no cão é exequível, porém suscita mais inflamação e complicações no pós-operatório.
APA, Harvard, Vancouver, ISO, and other styles
3

Correia, Renato José Bett, Hamilton Moreira, Sólon Uchoa Lago Netto, and Gleisson Rezende Pantaleão. "Performance visual após implante de LIO tórica em pacientes com astigmatismo corneano." Arquivos Brasileiros de Oftalmologia 72, no. 5 (October 2009): 636–40. http://dx.doi.org/10.1590/s0004-27492009000500007.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Mobricci, L. A. L., J. J. T. Ranzani, P. V. M. Steagall, A. C. L. Rodrigues, L. R. Carvalho, and C. V. S. Brandão. "Retinoscopia com luz em faixa em cães fácicos, afácicos e pseudofácicos." Arquivo Brasileiro de Medicina Veterinária e Zootecnia 61, no. 1 (February 2009): 20–26. http://dx.doi.org/10.1590/s0102-09352009000100004.

Full text
Abstract:
Avaliou-se o erro refracional em 40 cães submetidos ou não à facectomia por facoemulsificação, por meio de retinoscopia com luz em faixa. Distribuídos em quatro grupos de 10 animais cada, foram designados por cães fácicos, cães afácicos (CA), cães pseudofácicos com implante de duas lentes intra-oculares em piggyback (PP) e cães pseudofácicos com implante de uma lente intra-ocular veterinária de 41D (PL). As avaliações foram realizadas por ceratometria, ecobiometria ultra-sônica e retinoscopia. A média da curvatura corneana foi de 40,46±2,44D. O poder dióptrico obtido por retinoscopia foi de 18,50D no grupo CA, 5,25D no grupo PP e 2,00D no grupo PL. A retinoscopia com luz em faixa constituiu um método eficaz para avaliar a refração ocular em cães, mas foi dificultada quando da presença de opacidade de meios oculares. Todos os animais apresentaram-se hipermétropes, em diferentes graus; o astigmatismo ceratométrico cirurgicamente induzido foi discreto.
APA, Harvard, Vancouver, ISO, and other styles
5

Souza, V. L., C. H. Pellizzon, M. G. Sereno, R. T. Soares, J. J. T. Ranzani, A. C. L. Rodrigues, C. R. Padovani, and C. V. S. Brandão. "Avaliação histopatológica da cápsula posterior associada ao implante de lente intraocular com superfície modificada com plasma de flúor e polietilenoglicol em coelhos." Arquivo Brasileiro de Medicina Veterinária e Zootecnia 67, no. 5 (October 2015): 1295–303. http://dx.doi.org/10.1590/1678-4162-7975.

Full text
Abstract:
RESUMOO objetivo deste estudo foi avaliar o efeito do tratamento da superfície de lentes intraoculares acrílicas utilizando-se plasma de flúor ou polietilenoglicol na prevenção da opacidade de cápsula posterior. Foram analisados 40 olhos de coelhos, submetidos à cirurgia de facoemulsificação e distribuídos em quatro grupos experimentais (n=10), sendo estes: grupo controle, coelhos sem implante de lente intraocular; grupo com lente intraocular tratada com plasma de polietilenoglicol; grupo com lente intraocular tratada com plasma de flúor; e grupo com lente intraocular comercial. As cápsulas posteriores das lentes dos grupos foram avaliadas por meio de análise histopatológica (morfometria e imuno-histoquímica). Os grupos com lente intraocular tratada com polietilenoglicol e com lente intraocular comercial apresentaram menor espessura da cápsula posterior na avaliação inicial (12 semanas) em relação ao grupo controle. No período final de avaliação (6 meses), os tratamentos da superfície da lente intraocular à base de plasma de flúor e polietilenoglicol não reduziram o desenvolvimento das alterações histológicas associadas à opacidade de cápsula posterior. O tratamento das superfícies das lentes intraoculares com plasma de flúor e polietilenoglicol pode ser realizado como adjuvante na prevenção da opacidade de cápsula posterior, pois não causa alterações na morfologia da lente após facoemulsificação.
APA, Harvard, Vancouver, ISO, and other styles
6

Mattos, Armando Belfort, Pedro Paulo de Oliveira Bonomo, Lincoln Lemes Freitas, Michel Eid Farah, Harry Flynn Jr, and Maurício Bastos Pereira. "Facoemulsificação, vitrectomia via pars plana e implante de lente intra-ocular em olhos com retinopatia diabética proliferativa." Arquivos Brasileiros de Oftalmologia 67, no. 3 (June 2004): 441–49. http://dx.doi.org/10.1590/s0004-27492004000300014.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Pereira, Ricardo Antonio, Regina C. R. dos Santos, and Procópio Miguel dos Santos. "Contaminação bacteriana da câmara anterior pós-facoemulsificação com implante de lente intra-ocular de polimetilmetacrilato ou silicone." Arquivos Brasileiros de Oftalmologia 67, no. 6 (December 2004): 911–15. http://dx.doi.org/10.1590/s0004-27492004000600013.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Trindade, Fernando Cançado. "Piggyback secundário com LIO de PMMA para correção de surpresa refracional pós-facoemulsificação: resultados a longo prazo de 20 casos." Revista Brasileira de Oftalmologia 72, no. 1 (February 2013): 8–11. http://dx.doi.org/10.1590/s0034-72802013000100002.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Hida, Wilson Takashi, Antonio Francisco Pimenta Motta, Daniela Lumi Inomata, Martha de Queiroz Monteiro Jales, Antonio Carlos Facio Júnior, Newton Kara José Júnior, and Celso Takashi Nakano. "Incisões relaxantes limbares ou incisões no meridiano mais curvo associadas a facoemulsificação com implante de lente intra-ocular multifocal: relato de três casos." Arquivos Brasileiros de Oftalmologia 71, no. 2 (April 2008): 273–77. http://dx.doi.org/10.1590/s0004-27492008000200027.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Corrêa, Everton Paroschi, Luciana Freitas Lemos de Oliveira, Pedro Durães Serracarbassa, Akyioshi Oshima, and Emerson Fernandes de Sousa e. Castro. "Avaliação do edema macular após cirurgia não complicada de facoemulsificação com implante de lente intraocular por meio da tomografia de coerência óptica spectral domain." Arquivos Brasileiros de Oftalmologia 76, no. 6 (December 2013): 357–62. http://dx.doi.org/10.1590/s0004-27492013000600008.

Full text
APA, Harvard, Vancouver, ISO, and other styles

Dissertations / Theses on the topic "Facoemulsificação Com Implante de Lio"

1

Tronca, George Alfredo. "Prognóstico visual na cirurgia de facoemulsificação da catarata com implante de lente intra-ocular." Florianópolis, SC, 2004. http://repositorio.ufsc.br/xmlui/handle/123456789/86753.

Full text
Abstract:
Dissertação (mestrado) - Universidade Federal de Santa Catarina. Centro de Ciências da Saúde. Programa de Pós-graduação em Ciências Médicas
Made available in DSpace on 2012-10-21T10:18:23Z (GMT). No. of bitstreams: 1 213267.pdf: 822390 bytes, checksum: 87afe91e1a2c036864bdd7dd8fc324e5 (MD5)
Objetivo: Investigar o prognóstico visual em indivíduos portadores de catarata, operados pela técnica de facoemulsificação endocapsular do cristalino com implante de lente intra-ocular
APA, Harvard, Vancouver, ISO, and other styles
2

Rodrigues, Georgia Nadalini [UNESP]. "Estudo clínico da facoemulsificação em cães, com e sem implante de lente intra-ocular em piggyback." Universidade Estadual Paulista (UNESP), 2005. http://hdl.handle.net/11449/101186.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:31:09Z (GMT). No. of bitstreams: 0 Previous issue date: 2005Bitstream added on 2014-06-13T18:41:49Z : No. of bitstreams: 1 rodrigues_gn_dr_botfmvz.pdf: 4865487 bytes, checksum: 4d614b1bb25a841f92667f0c608bf5b7 (MD5)
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
O objetivo do presente estudo foi avaliar o comportamento do olho canino após a cirurgia para extração de catarata, com e sem implante de lente intra-ocular (LIO) em piggyback, frente a pressão intra-ocular, espessura e curvatura corneanas, densidade e área das células do endotélio da córnea. Empregaram-se, 25 animais da espécie canina de sexo, raça e idades variadas, portadores de catarata, subdivididos em 4 grupos designados por G1 (cães portadores de catarata imatura, com implante de LIO), G2 (cães portadores de catarata madura, com implante de LIO), G3 (cães portadores de catarata imatura, sem implante de LIO) e G4 (cães portadores de catarata madura, sem implante de LIO). A técnica cirúrgica foi a facoemulsificação bimanual. As avaliações da pressão intra-ocular, curvatura e espessura da córnea, foram aferidas antes do procedimento cirúrgico (0) enquanto que, as avaliações das densidade e área das células do endotélio corneano foram realizadas antes do procedimento cirúrgico (0) e nos tempos 7, 28 e 60 dias após o procedimento cirúrgico. A estatística utilizada foi a Análise de Perfil, seguida do método de Tukey para comparações múltiplas, com nível de significância de 5%. Os resultados não demonstraram diferença significativa entre os quatro grupos analisados, no entanto, houve diferença na comparação entre os olhos operados e os contra-laterais. A avaliação qualitativa realizada durante o pós-operatório demonstrou uma maior reação inflamatória e um maior índice de complicações entre os animais dos grupos 1 e 2. Concluí-se que não houve diferença entre os grupos, no entanto, demonstrou-se diferença entre o olho operado e não-operado. Entretanto, o pós-operatório dos animais dos grupos 1 e 2 revelou-se mais complicado, expressando uma reação inflamatória mais exacerbada e um maior índice de complicações.
The purpose of this study was to investigate the effects in intraocular pressure, central corneal thickness, corneal curvature, cellular density and area of corneal endothelium after surgery for cataract extraction with and without intraocular lens (IOL) implantation using piggyback technique in eyes of dogs. A total of 25 dogs were divided into 4 groups: Group 1 (dogs with immature cataract and with IOL implantation), Group 2 (dogs with mature cataract and with IOL implantation), Group 3 (dogs with immature cataract and without IOL implantation) and Group 4 (dogs with mature cataract and without IOL implantation). The surgical technique performed was bimanual phacoemulsification. Intraocular pressure, central corneal thickness and corneal curvature were measured before surgery (0) and at 3, 7, 14, 21, 28, 60 days of postoperative. Cellular density and area of corneal endothelium were measured before surgery and at 7, 28, 60 days of postoperative. Statistical analysis was performed using variance analysis (profile) and Tukey test for multiple comparison with significance at p<0.05. The 4 groups did not differ significantly with respect to parameters evaluated. There was, however, a significant difference between the two eyes (operated and nonoperated). However, the dogs of groups 1 and 2 had more complicate postoperative with more severe ocular inflammation and number of complications.
APA, Harvard, Vancouver, ISO, and other styles
3

Lacerda, Luciana de Cenço Corrêa de [UNESP]. "Condições do humor aquoso, quanto à contaminação, na facoemulsificação com implante de lente intraocular em cães." Universidade Estadual Paulista (UNESP), 2014. http://hdl.handle.net/11449/110440.

Full text
Abstract:
Made available in DSpace on 2014-11-10T11:09:44Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-01-24Bitstream added on 2014-11-10T11:58:32Z : No. of bitstreams: 1 000790830.pdf: 1275790 bytes, checksum: ee43ae79b4dc2bfb622479f1f9fcbf29 (MD5)
O tratamento cirúrgico para a catarata, pela facoemulsificação, é atualmente o mais aceito e praticado. A utilização de lentes intraoculares (LIO), indicadas para a correção da emetropia e para a profilaxia da opacificação da cápsula posterior, pode, todavia, ensejar contaminação advinda da cavidade nasal e da conjuntiva palpebral, além do ambiente, da equipe cirúrgica, de materiais e de instrumentais. Com o trabalho, objetivou-se a identificação de linhagens de bactérias presentes nas secreções nasal e conjuntival e no humor aquoso de cães submetidos à facoemulsificação com implante de lentes intraoculares, bem como a caracterização da diversidade genética entre as populações encontradas, empregando-se o sequenciamento da região 16S rDNA de microrganismos, após seleção de diferentes grupos pela Rep-PCR, com o primer BoxA1 associado ao BoxC1R. Encontraram-se bactérias dos gêneros Enterobacter, Staphylococcus, Streptococcus e Pantoea e a espécie Staphylococcus aureus. Pela PCR-RFLP, utilizando-se a enzima MboI, identificaram-se espécies de Staphylococcus, como o S. pseudointermedius. Foram encontrados dois exemplares de Staphylococcus aureus coagulase positivo, pela PCR, confirmados pelo teste bioquímico da coagulase. Os isolados foram submetidos à Rep-PCR com marcadores moleculares Rep1R-I associado ao Rep2, Eric2 e BoxC1R. Encontrou-se alta variabilidade genética entre eles, notadamente quanto ao gênero Staphylococcus. O sequenciamento da região 16S rDNA e a Rep-PCR foram factíveis na detecção da diversidade genética. Oito isolados do gênero Enterobacter em secreção conjuntival e, ao mesmo tempo, no humor aquoso, apresentaram distância genética de 0.000. Cinco por cento dos pacientes submetidos à facoemulsificação com implante de LIO apresentaram contaminação do humor aquoso, por Enterobacter spp
Phacoemulsification is the surgical treatment most commonly performed and accepted for cataracts. The use of artificial intraocular lens (IOL), indicated to achieve emetropy and as an aid on the prophylaxis of posterior capsule opacification, may, however, give rise to contamination arising from the nasal cavity and palpebral conjunctiva, in addition to the environment, the surgical staff, materials and instrumental. The goal of this research was to identify strains of bacteria present in the nasal and conjunctival secretions and aqueous humor of dogs undergoing phacoemulsification with implantation of intraocular lenses, as well as the characterization of genetic diversity among populations found using it sequencing of 16S rDNA of microorganisms, after selection of different groups by Rep-PCR with the primer BoxA1 associated BoxC1R. This study founded genders of bacteria like Enterobacter, Staphylococcus, Streptococcus and Pantoea and Staphylococcus aureus species. PCR-RFLP, using the enzyme MboI, identified Staphylococcus species such as S. pseudointermedius. Two copies of coagulase positive Staphylococcus aureus, founded by PCR, were confirmed by biochemical coagulase test. All of isolates was submitted by Rep-PCR with molecular markers Rep1R-I associated with Rep2, Eric2 and BoxC1R. It was found high genetic variability among them, especially regarding the gender Staphylococcus. Sequencing of 16S rDNA and Rep-PCR were effective in detecting genetic diversity. Eight isolates of gender Enterobacter in the conjunctival secretion and, at the same time, in aqueous humor, showed genetic distance of 0.000. Five percent of patients submitted to phacoemulsification with IOL implantation showed contamination in aqueous humor, by Enterobacter spp
APA, Harvard, Vancouver, ISO, and other styles
4

Rodrigues, Georgia Nadalini. "Estudo clínico da facoemulsificação em cães, com e sem implante de lente intra-ocular em piggyback /." Botucatu : [s.n.], 2005. http://hdl.handle.net/11449/101186.

Full text
Abstract:
Orientador: José Joaquim Titton Ranzani
Resumo: O objetivo do presente estudo foi avaliar o comportamento do olho canino após a cirurgia para extração de catarata, com e sem implante de lente intra-ocular (LIO) em piggyback, frente a pressão intra-ocular, espessura e curvatura corneanas, densidade e área das células do endotélio da córnea. Empregaram-se, 25 animais da espécie canina de sexo, raça e idades variadas, portadores de catarata, subdivididos em 4 grupos designados por G1 (cães portadores de catarata imatura, com implante de LIO), G2 (cães portadores de catarata madura, com implante de LIO), G3 (cães portadores de catarata imatura, sem implante de LIO) e G4 (cães portadores de catarata madura, sem implante de LIO). A técnica cirúrgica foi a facoemulsificação bimanual. As avaliações da pressão intra-ocular, curvatura e espessura da córnea, foram aferidas antes do procedimento cirúrgico (0) enquanto que, as avaliações das densidade e área das células do endotélio corneano foram realizadas antes do procedimento cirúrgico (0) e nos tempos 7, 28 e 60 dias após o procedimento cirúrgico. A estatística utilizada foi a Análise de Perfil, seguida do método de Tukey para comparações múltiplas, com nível de significância de 5%. Os resultados não demonstraram diferença significativa entre os quatro grupos analisados, no entanto, houve diferença na comparação entre os olhos operados e os contra-laterais. A avaliação qualitativa realizada durante o pós-operatório demonstrou uma maior reação inflamatória e um maior índice de complicações entre os animais dos grupos 1 e 2. Concluí-se que não houve diferença entre os grupos, no entanto, demonstrou-se diferença entre o olho operado e não-operado. Entretanto, o pós-operatório dos animais dos grupos 1 e 2 revelou-se mais complicado, expressando uma reação inflamatória mais exacerbada e um maior índice de complicações.
Abstract: The purpose of this study was to investigate the effects in intraocular pressure, central corneal thickness, corneal curvature, cellular density and area of corneal endothelium after surgery for cataract extraction with and without intraocular lens (IOL) implantation using piggyback technique in eyes of dogs. A total of 25 dogs were divided into 4 groups: Group 1 (dogs with immature cataract and with IOL implantation), Group 2 (dogs with mature cataract and with IOL implantation), Group 3 (dogs with immature cataract and without IOL implantation) and Group 4 (dogs with mature cataract and without IOL implantation). The surgical technique performed was bimanual phacoemulsification. Intraocular pressure, central corneal thickness and corneal curvature were measured before surgery (0) and at 3, 7, 14, 21, 28, 60 days of postoperative. Cellular density and area of corneal endothelium were measured before surgery and at 7, 28, 60 days of postoperative. Statistical analysis was performed using variance analysis (profile) and Tukey test for multiple comparison with significance at p<0.05. The 4 groups did not differ significantly with respect to parameters evaluated. There was, however, a significant difference between the two eyes (operated and nonoperated). However, the dogs of groups 1 and 2 had more complicate postoperative with more severe ocular inflammation and number of complications.
Doutor
APA, Harvard, Vancouver, ISO, and other styles
5

Lacerda, Luciana de Cenço Corrêa de. "Condições do humor aquoso, quanto à contaminação, na facoemulsificação com implante de lente intraocular em cães /." Jaboticabal, 2014. http://hdl.handle.net/11449/110440.

Full text
Abstract:
Orientador: José Luiz Laus
Coorientador: Renato Pariz Maluta
Banca: Paola Castro Moraes
Banca: Cristiane dos Santos Honsho
Resumo: O tratamento cirúrgico para a catarata, pela facoemulsificação, é atualmente o mais aceito e praticado. A utilização de lentes intraoculares (LIO), indicadas para a correção da emetropia e para a profilaxia da opacificação da cápsula posterior, pode, todavia, ensejar contaminação advinda da cavidade nasal e da conjuntiva palpebral, além do ambiente, da equipe cirúrgica, de materiais e de instrumentais. Com o trabalho, objetivou-se a identificação de linhagens de bactérias presentes nas secreções nasal e conjuntival e no humor aquoso de cães submetidos à facoemulsificação com implante de lentes intraoculares, bem como a caracterização da diversidade genética entre as populações encontradas, empregando-se o sequenciamento da região 16S rDNA de microrganismos, após seleção de diferentes grupos pela Rep-PCR, com o primer BoxA1 associado ao BoxC1R. Encontraram-se bactérias dos gêneros Enterobacter, Staphylococcus, Streptococcus e Pantoea e a espécie Staphylococcus aureus. Pela PCR-RFLP, utilizando-se a enzima MboI, identificaram-se espécies de Staphylococcus, como o S. pseudointermedius. Foram encontrados dois exemplares de Staphylococcus aureus coagulase positivo, pela PCR, confirmados pelo teste bioquímico da coagulase. Os isolados foram submetidos à Rep-PCR com marcadores moleculares Rep1R-I associado ao Rep2, Eric2 e BoxC1R. Encontrou-se alta variabilidade genética entre eles, notadamente quanto ao gênero Staphylococcus. O sequenciamento da região 16S rDNA e a Rep-PCR foram factíveis na detecção da diversidade genética. Oito isolados do gênero Enterobacter em secreção conjuntival e, ao mesmo tempo, no humor aquoso, apresentaram distância genética de 0.000. Cinco por cento dos pacientes submetidos à facoemulsificação com implante de LIO apresentaram contaminação do humor aquoso, por Enterobacter spp
Abstract: Phacoemulsification is the surgical treatment most commonly performed and accepted for cataracts. The use of artificial intraocular lens (IOL), indicated to achieve emetropy and as an aid on the prophylaxis of posterior capsule opacification, may, however, give rise to contamination arising from the nasal cavity and palpebral conjunctiva, in addition to the environment, the surgical staff, materials and instrumental. The goal of this research was to identify strains of bacteria present in the nasal and conjunctival secretions and aqueous humor of dogs undergoing phacoemulsification with implantation of intraocular lenses, as well as the characterization of genetic diversity among populations found using it sequencing of 16S rDNA of microorganisms, after selection of different groups by Rep-PCR with the primer BoxA1 associated BoxC1R. This study founded genders of bacteria like Enterobacter, Staphylococcus, Streptococcus and Pantoea and Staphylococcus aureus species. PCR-RFLP, using the enzyme MboI, identified Staphylococcus species such as S. pseudointermedius. Two copies of coagulase positive Staphylococcus aureus, founded by PCR, were confirmed by biochemical coagulase test. All of isolates was submitted by Rep-PCR with molecular markers Rep1R-I associated with Rep2, Eric2 and BoxC1R. It was found high genetic variability among them, especially regarding the gender Staphylococcus. Sequencing of 16S rDNA and Rep-PCR were effective in detecting genetic diversity. Eight isolates of gender Enterobacter in the conjunctival secretion and, at the same time, in aqueous humor, showed genetic distance of 0.000. Five percent of patients submitted to phacoemulsification with IOL implantation showed contamination in aqueous humor, by Enterobacter spp
Mestre
APA, Harvard, Vancouver, ISO, and other styles
6

Teixeira, Adriana Lima. "Estudo comparativo do estresse oxidativo após facoemulsificação experimental com e sem implante de lentes intra-oculares em cães." Universidade de São Paulo, 2003. http://www.teses.usp.br/teses/disponiveis/10/10137/tde-10012005-121705/.

Full text
Abstract:
O tratamento da catarata em cães têm passado por algumas mudanças. A facoemulsificação reduziu o tempo cirúrgico e a necessidade de incisão extensa; o implante de lentes intra-oculares (LIOs) permitiu restabelecer a emetropia após a remoção do cristalino. O processo inflamatório induzido pelas cirurgias intra-oculares leva a um estado de estresse oxidativo, com efeitos deletérios às estruturas oculares. O presente estudo teve como objetivo avaliar comparativamente o estresse oxidativo após facoemulsificação experimental em cães, com e sem implante de LIO. Doze cães (três machos e nove fêmeas), sem raça definida, com peso médio de 15,8kg, foram submetidos à facoemulsificação bilateral, sendo doze olhos sem implante de LIO (Grupo 1) e doze olhos com implante de LIO de polimetilmetacrilato no saco capsular (Grupo 2). Os animais foram medicados nos períodos pré-operatório e pós-operatório com antiinflamatórios, antibióticos e midriáticos. As amostras de humor aquoso (HA) foram obtidas por paracentese de câmara anterior, sob anestesia geral, nos períodos pré-operatório (T0) e pós-operatório com 1 dia (T1), 2 dias (T2), 3 dias (T3), 7 dias (T7) e 14 dias (T14). O estresse oxidativo foi avaliado por meio da determinação quantitativa de proteínas no HA (método de Lowry), avaliação da atividade antioxidante total do HA utilizando o AAPH, cloreto de 2,2'azobis (2-metilamidinopropano) e avaliação da concentração de ácido ascórbico no HA e no plasma (cromatografia líquida de alta eficiência). Os resultados foram submetidos à análise estatística, utilizando-se o teste t de Student, quando as variáveis apresentaram distribuição normal, e pelo teste de Wilcoxon, quando não houve distribuição normal. Os níveis de proteína total no HA aumentaram nos dois grupos, sendo de forma mais acentuada no Grupo 2 em todos os tempos pós-operatórios: T1 (p= 0,004), T2 (p= 0,002), T3 (p= 0,004), T7 (p= 0,003) e T14 (p= 0,009). A atividade antioxidante total do HA apresentou uma diminuição nos dois grupos, mais acentuada, entretanto, no Grupo 2, com diferença estatisticamente significante nos tempos T1 (p= 0,013), T2 (p= 0,016), T3 (p= 0,002) e T14 (p= 0,033). No tempo T7 (p= 0,155) essa diferença não foi observada. A concentração de ácido ascórbico no HA apresentou uma diminuição marcante no primeiro dia do pós-operatório, seguida por uma recuperação progressiva nos dois grupos. O Grupo 2 mostrou resultados mais baixos, com diferença estatisticamente significante nos tempos T1 (p= 0,003), T3 (p= 0,015), T7 (p= 0,004) e T14 (p= 0,007), exceto em T2 (p= 0,051), quando não houve diferença. A concentração de ácido ascórbico no plasma não variou em função dos procedimentos. A comparação entre os procedimentos sugere que o implante de LIO contribui para a condição de estresse oxidativo.
The cataract treatment in dogs has undergone some changes. Phacoemulsification has reduced the surgical time of cataract extraction and the need of large incision. Intraocular lens (IOL) implantation has allowed emetropic vision recovery. The inflammatory process induced by intraocular surgery leads to an oxidative stress, with ocular structures damage. The purpose of this study was to comparatively evaluate the oxidative stress following phacoemulsification in dogs with and without IOL implantation. Twelve dogs, three male and nine female, mixed breed, with an average weight of 15.8kg were submitted to bilateral phacoemulsification, being twelve eyes without IOL implantation (Group 1) and twelve eyes with polymethylmethacrylate IOL in the capsular bag (Group 2). In the pre-operative and post-operative periods, the medication consisted of anti-inflammatories, antibiotics and mydriatics. Aqueous humor (AH) samples were taken by anterior chamber paracentesis, under general anesthesia in the pre-operative (T0) and post-operative periods after 1 (T1), 2 (T2), 3 (T3), 7 (T7) and 14 (T14) days of the surgery. The oxidative stress was evaluated by quantitative protein levels in the AH (Lowry’s method), total antioxidant activity in the AH using 2,2’ azobis (2-methylpropionamidine) dihydrochloride (AAPH) and ascorbic acid concentration in the AH and plasma (high performance liquid chromatography). Results were submitted to statistical analysis using the t-student test when the variables had a normal distribution and Wilcoxon test when they did not. Aqueous humor total protein levels increased in both groups, more intensively in Group 2 in all post-operative periods: T1 (p= 0.004), T2 (p= 0.002), T3 (p= 0.004), T7 (p= 0.003) and T14 (p= 0.009). Total antioxidant activity in the AH decreased in both groups; however, it was more impressive in Group 2, with statistical significant difference in T1 (p= 0.013), T2 (p= 0.016), T3 (p= 0.002) e T14 (p= 0.033). In T7 (p= 0.155), this difference was not observed. Ascorbic acid concentration in the AH presented a remarkably decrease in the first post-operative day, then started to recover progressively in the two groups. Group 2 showed lower results with statistically significant differences in T1 (p= 0.003); T3 (p= 0.015); T7 (p= 0.004) and T14 (p= 0.007), except in T2 (p= 0.051) when there was no difference. Ascorbic acid concentration in plasma did not vary as a result of the procedures. The comparison between procedures suggests that IOL implantation contributes to an oxidative stress condition.
APA, Harvard, Vancouver, ISO, and other styles
7

Sereno, Maria Guadalupe [UNESP]. "Avaliação da opacidade da cápsula posterior, após facoemulsificação e implante de lente intraocular modificada com plasma de flúor ou polietilenoglicol com coelhos." Universidade Estadual Paulista (UNESP), 2012. http://hdl.handle.net/11449/101037.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:31:06Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-07-17Bitstream added on 2014-06-13T19:01:25Z : No. of bitstreams: 1 sereno_mg_dr_botfmvz_parcial.pdf: 72346 bytes, checksum: 24da52ea5130e16c644610e364994910 (MD5) Bitstreams deleted on 2015-06-03T11:42:25Z: sereno_mg_dr_botfmvz_parcial.pdf,. Added 1 bitstream(s) on 2015-06-03T11:43:59Z : No. of bitstreams: 1 000712342_20150717.pdf: 60183 bytes, checksum: f2f25c4e5338aff3c47a47401ac44f4c (MD5) Bitstreams deleted on 2015-08-03T12:21:14Z: 000712342_20150717.pdf,. Added 1 bitstream(s) on 2015-08-03T12:22:26Z : No. of bitstreams: 1 000712342.pdf: 763726 bytes, checksum: 73e045192f5db1c78737d496e8c80ca0 (MD5)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
A opacidade de cápsula posterior (OCP) é a complicação tardia mais comum após remoção da catarata por facoemulsificação e constitui uma nova barreira à passagem da luz. A modificação superficial das lentes intraoculares (LIOs) e tratamento por plasma vêm sendo estudados, com o intuito de aumentar a biocompatibilidade das mesmas e induzir menor proliferação celular com a posterior manifestação da OCP. O presente estudo teve por objetivo avaliar e comparar a OCP, bem como as variáveis clínico-oftalmológicas após facoemulsificação e implante de lente intraocular (LIO), modificada com plasma de flúor (SF6) ou de polietilenoglicol (PEG), em coelhos. Foram constituídos quatro grupos, de 10 animais cada. Todos os coelhos foram submetidos à facoemulsificação, sendo este o único procedimento no grupo GF; os animais do GL receberam o implante de LIOs hidrofílicas sem tratamento; no GP foram implantadas LIOs tratadas com plasma de flúor, e no GPeg LIOs polimerizadas com plasma de polietilenoglicol. Após o procedimento cirúrgico, foi feita a avaliação macroscópica e semiquantitativa da OCP, opacidade de cápsula anterior (OCA) e fimose capsular, pela lâmpada de fenda, bem como foi mensurada a pressão intraocular (PIO) e analisada espessura corneal e endotélio por microscopia especular. Adicionalmente, foi realizada a fotodocumentação digital por retroiluminação da cápsula posterior foram analisadas quanto à OCP, utilizando-se o software POCOman (Posterior Capsule Opacification Manual), até as doze e 24 semanas do pós-operatório, nos momentos de avaliação precoce e tardia respectivamente. Na avaliação clínica oftalmológica e do endotélio da córnea não houve diferença significativa entre os grupos. A OCP foi menos intensa nos grupos tratados por plasma, na biomicroscopia. O GF apresentou...
Intraocular lenses surface modification and plasma treatment are being studied, in order to increase the biocompatibility and induce less cell proliferation with the later manifestation of posterior capsule opacification (PCO). The present study aimed to evaluate and compare the PCO, as well as clinical and ophthalmological variables after phacoemulsification and intraocular lens implantation (IOL), modified with fluoride (SF6) plasma or poly (ethylene) glycol (PEG), in rabbits. Four groups with 10 animals each were constituted. All rabbits were submitted to phacoemulsification, being this the only procedure in GF group; the GL animals received the implant of hydrophilic IOLs; GP received fluoride plasma treated IOLs, and GPeg poly (ethylene glycol) plasma-polymerized IOLs. After the surgical procedure, the PCO macroscopic evaluation was made of the OCP, anterior capsule opacification (OCA) and capsular phimosis by slit-lamp, as well as was measured the intraocular pressure (IOP) and analyzed corneal thickness and endothelium by specular microscopy. Additionally, digital photographs by backlight of posterior capsule were analysed as to the OCP, using the software POCOman (Posterior Capsule Opacification Manual), until the 12 and 24 postoperative weeks in early and late evaluation respectively. In clinical assessing eye cornea and endothelium there was no significant difference between the groups. To slit lamp exam PCO was less intense in the groups treated by plasma. The GF had the highest rates of anterior capsule opacity and capsular phimosis in relation to groups with IOL. POCOman, was not evidenced in effect in reducing the PCO in the group treated by Fluoride in relation to non treated. The implant of IOLs treated with plasma does not promote inflammatory eye signs and endothelial additionally changes, demonstrating... (Complete abstract click electronic access below)
APA, Harvard, Vancouver, ISO, and other styles
8

Sereno, Maria Guadalupe. "Avaliação da opacidade da cápsula posterior, após facoemulsificação e implante de lente intraocular modificada com plasma de flúor ou polietilenoglicol com coelhos /." Botucatu, 2012. http://hdl.handle.net/11449/101037.

Full text
Abstract:
Orientador: Cláudia Valéria Seuller Brandão
Coorientador: Antônio Carlos Lotelli Rodrigues
Banca: José Joaquim Titon Ranzani
Banca: Silvana Artioli Schellini
Banca: Georgia Nadalini Rodrigues
Banca: Cláudia Helena Pellizzon
Resumo: A opacidade de cápsula posterior (OCP) é a complicação tardia mais comum após remoção da catarata por facoemulsificação e constitui uma nova barreira à passagem da luz. A modificação superficial das lentes intraoculares (LIOs) e tratamento por plasma vêm sendo estudados, com o intuito de aumentar a biocompatibilidade das mesmas e induzir menor proliferação celular com a posterior manifestação da OCP. O presente estudo teve por objetivo avaliar e comparar a OCP, bem como as variáveis clínico-oftalmológicas após facoemulsificação e implante de lente intraocular (LIO), modificada com plasma de flúor (SF6) ou de polietilenoglicol (PEG), em coelhos. Foram constituídos quatro grupos, de 10 animais cada. Todos os coelhos foram submetidos à facoemulsificação, sendo este o único procedimento no grupo GF; os animais do GL receberam o implante de LIOs hidrofílicas sem tratamento; no GP foram implantadas LIOs tratadas com plasma de flúor, e no GPeg LIOs polimerizadas com plasma de polietilenoglicol. Após o procedimento cirúrgico, foi feita a avaliação macroscópica e semiquantitativa da OCP, opacidade de cápsula anterior (OCA) e fimose capsular, pela lâmpada de fenda, bem como foi mensurada a pressão intraocular (PIO) e analisada espessura corneal e endotélio por microscopia especular. Adicionalmente, foi realizada a fotodocumentação digital por retroiluminação da cápsula posterior foram analisadas quanto à OCP, utilizando-se o software POCOman (Posterior Capsule Opacification Manual), até as doze e 24 semanas do pós-operatório, nos momentos de avaliação precoce e tardia respectivamente. Na avaliação clínica oftalmológica e do endotélio da córnea não houve diferença significativa entre os grupos. A OCP foi menos intensa nos grupos tratados por plasma, na biomicroscopia. O GF apresentou... (Resumo completo, clicar acesso eletrônico abaixo)
Abstract: Intraocular lenses surface modification and plasma treatment are being studied, in order to increase the biocompatibility and induce less cell proliferation with the later manifestation of posterior capsule opacification (PCO). The present study aimed to evaluate and compare the PCO, as well as clinical and ophthalmological variables after phacoemulsification and intraocular lens implantation (IOL), modified with fluoride (SF6) plasma or poly (ethylene) glycol (PEG), in rabbits. Four groups with 10 animals each were constituted. All rabbits were submitted to phacoemulsification, being this the only procedure in GF group; the GL animals received the implant of hydrophilic IOLs; GP received fluoride plasma treated IOLs, and GPeg poly (ethylene glycol) plasma-polymerized IOLs. After the surgical procedure, the PCO macroscopic evaluation was made of the OCP, anterior capsule opacification (OCA) and capsular phimosis by slit-lamp, as well as was measured the intraocular pressure (IOP) and analyzed corneal thickness and endothelium by specular microscopy. Additionally, digital photographs by backlight of posterior capsule were analysed as to the OCP, using the software POCOman (Posterior Capsule Opacification Manual), until the 12 and 24 postoperative weeks in early and late evaluation respectively. In clinical assessing eye cornea and endothelium there was no significant difference between the groups. To slit lamp exam PCO was less intense in the groups treated by plasma. The GF had the highest rates of anterior capsule opacity and capsular phimosis in relation to groups with IOL. POCOman, was not evidenced in effect in reducing the PCO in the group treated by Fluoride in relation to non treated. The implant of IOLs treated with plasma does not promote inflammatory eye signs and endothelial additionally changes, demonstrating... (Complete abstract click electronic access below)
Doutor
APA, Harvard, Vancouver, ISO, and other styles
9

Pavan, Priscila Teodoro [UNESP]. "Avaliação ultrassonográfica do bulbo ocular em cães submetidos à facectomia por facoemulsificação com ou sem implante de lente intraocular." Universidade Estadual Paulista (UNESP), 2011. http://hdl.handle.net/11449/89153.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:23:45Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-06-29Bitstream added on 2014-06-13T19:30:17Z : No. of bitstreams: 1 pavan_pt_me_botfmvz.pdf: 3799267 bytes, checksum: 720cd0e9fdd18a21ac4ccee753679f56 (MD5)
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
O exame ultrassonográfico tem sido utilizado para diagnóstico das doenças oftálmicas humanas desde 1956, já em Medicina Veterinária o seu uso foi somente descrito em 1968; ainda tem sido muito pouco empregado para auxílio no pósoperatório de catarata, onde possui grande importância no diagnóstico de alterações decorrentes da facectomia. O presente trabalho teve por objetivo descrever e comparar as alterações ultrassonográficas encontradas em bulbos oculares de cães submetidos à facectomia por facoemulsificação, com ou sem implante de lente intraocular (LIO), no intuito de auxiliar no diagnóstico de possíveis alterações decorrentes do procedimento cirúrgico e do implante da LIO, bem como sua correspondência com alterações clínicas. Foram utilizados 19 cães machos e fêmeas portadores de catarata já operados, de várias raças e idades, saudáveis, não diabéticos e submetidos à facectomia por facoemulsificação, resultando em 21 bulbos oculares avaliados. Os animais inicialmente foram submetidos a exame oftálmico completo, em ambiente de baixa luminosidade, e em seguida ao exame ultrassonográfico. Foram constituídos três grupos: um de 11 bulbos oculares, CA (cães afácicos), outro de 05 bulbos oculares PP (cães pseudofácicos com implante de duas LIOs em piggyback) e outro PL de 05 bulbos oculares com implante de uma LIO veterinária de 41 D. O exame ultrassonográfico foi realizado sob administração tópica de colírio anestésico oftálmico1, com transdutor linear multifrequencial de 6 a 10 MHz pelas técnicas transpalpebral e corneal. Clinicamente, foram observadas diferentes alterações, dentre elas: luxação da LIO, descolamento de retina, hialose asteróide e degeneração vítrea que foram, posteriormente, confirmadas e classificadas pelo exame ultrassonográfico. Os grupos não mostraram...
The ultrasound has been used for diagnosis of human ophthalmic disease since 1956, veterinary medicine in their use was only described in 1968. The present study aims to describe and compare the ultrasonographic alterations encountered in dogs which underwent facectomy through facoemulsification with or without intraocular lens implant (IOL), in an attempt to assist the diagnosis of possible alterations due to the surgical procedure and IOL implantation, as well as their relation to corresponding clinical signs. The study group was composed by 19 male and female healthy, non-diabetic dogs of various breeds and ages, which had already had surgery for cataract, adding up to the evaluation of 21 ocular bulbs. The animals were initially submitted to complete ophthalmological exams, in a dim environment which preceded the sonogram. Subsequently, the subjects were divided into three distinct groups: Aphakic dogs (CA), pseudophakic dogs implanted with two piggyback IOLs (PP) and dogs implanted with a 41D veterinary IOL (PL), which consisted of 11, 05 and 5 ocular bulbs, respectively. The ultrasound was carried under the topic administration of an anesthetic eye drop1, with a multi frequency linear transducer of 6 to 10 MHz through the transpalpebral and transcorneal technique. The clinical alterations observed were luxation of the IOL, retinal dislocation, asteroid hyalosis, and vitreous degeneration. No statistic difference in the descriptive measures of the variables regarding the ocular axis and the anterior chamber was found, however, when comparing measurements of the cilliar body and the vitreal chamber, the PP group... (Complete abstract click electronic access below)
APA, Harvard, Vancouver, ISO, and other styles
10

Pavan, Priscila Teodoro. "Avaliação ultrassonográfica do bulbo ocular em cães submetidos à facectomia por facoemulsificação com ou sem implante de lente intraocular /." Botucatu : [s.n.], 2011. http://hdl.handle.net/11449/89153.

Full text
Abstract:
Orientador: José Joaquim Titton Ranzani
Banca: Maria Jaqueline Mamprim
Banca: Geórgia Nadalini Rodrigues
Resumo: O exame ultrassonográfico tem sido utilizado para diagnóstico das doenças oftálmicas humanas desde 1956, já em Medicina Veterinária o seu uso foi somente descrito em 1968; ainda tem sido muito pouco empregado para auxílio no pósoperatório de catarata, onde possui grande importância no diagnóstico de alterações decorrentes da facectomia. O presente trabalho teve por objetivo descrever e comparar as alterações ultrassonográficas encontradas em bulbos oculares de cães submetidos à facectomia por facoemulsificação, com ou sem implante de lente intraocular (LIO), no intuito de auxiliar no diagnóstico de possíveis alterações decorrentes do procedimento cirúrgico e do implante da LIO, bem como sua correspondência com alterações clínicas. Foram utilizados 19 cães machos e fêmeas portadores de catarata já operados, de várias raças e idades, saudáveis, não diabéticos e submetidos à facectomia por facoemulsificação, resultando em 21 bulbos oculares avaliados. Os animais inicialmente foram submetidos a exame oftálmico completo, em ambiente de baixa luminosidade, e em seguida ao exame ultrassonográfico. Foram constituídos três grupos: um de 11 bulbos oculares, CA (cães afácicos), outro de 05 bulbos oculares PP (cães pseudofácicos com implante de duas LIOs em piggyback) e outro PL de 05 bulbos oculares com implante de uma LIO veterinária de 41 D. O exame ultrassonográfico foi realizado sob administração tópica de colírio anestésico oftálmico1, com transdutor linear multifrequencial de 6 a 10 MHz pelas técnicas transpalpebral e corneal. Clinicamente, foram observadas diferentes alterações, dentre elas: luxação da LIO, descolamento de retina, hialose asteróide e degeneração vítrea que foram, posteriormente, confirmadas e classificadas pelo exame ultrassonográfico. Os grupos não mostraram... (Resumo completo, clicar acesso eletrônico abaixo)
Abstract: The ultrasound has been used for diagnosis of human ophthalmic disease since 1956, veterinary medicine in their use was only described in 1968. The present study aims to describe and compare the ultrasonographic alterations encountered in dogs which underwent facectomy through facoemulsification with or without intraocular lens implant (IOL), in an attempt to assist the diagnosis of possible alterations due to the surgical procedure and IOL implantation, as well as their relation to corresponding clinical signs. The study group was composed by 19 male and female healthy, non-diabetic dogs of various breeds and ages, which had already had surgery for cataract, adding up to the evaluation of 21 ocular bulbs. The animals were initially submitted to complete ophthalmological exams, in a dim environment which preceded the sonogram. Subsequently, the subjects were divided into three distinct groups: Aphakic dogs (CA), pseudophakic dogs implanted with two piggyback IOLs (PP) and dogs implanted with a 41D veterinary IOL (PL), which consisted of 11, 05 and 5 ocular bulbs, respectively. The ultrasound was carried under the topic administration of an anesthetic eye drop1, with a multi frequency linear transducer of 6 to 10 MHz through the transpalpebral and transcorneal technique. The clinical alterations observed were luxation of the IOL, retinal dislocation, asteroid hyalosis, and vitreous degeneration. No statistic difference in the descriptive measures of the variables regarding the ocular axis and the anterior chamber was found, however, when comparing measurements of the cilliar body and the vitreal chamber, the PP group... (Complete abstract click electronic access below)
Mestre
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!

To the bibliography