To see the other types of publications on this topic, follow the link: Failure analysis of medical devices.

Dissertations / Theses on the topic 'Failure analysis of medical devices'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 50 dissertations / theses for your research on the topic 'Failure analysis of medical devices.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.

1

Hosseinipour, Milad. "Design and Development of an Intra-Ventricular Assistive Device For End Stage Congestive Heart Failure Patients: Conceptual Design." University of Toledo / OhioLINK, 2013. http://rave.ohiolink.edu/etdc/view?acc_num=toledo1372726495.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Hamandi, Farah Mohammed Ridha Abdulateef. "Hierarchical Structure, Properties and Bone Mechanics at Macro, Micro, and Nano Levels." Wright State University / OhioLINK, 2020. http://rave.ohiolink.edu/etdc/view?acc_num=wright1607294294076853.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Heffner, Heather Ann. "Analysis of post-use hypodermic needle medical waste disposal." Thesis, Available online, Georgia Institute of Technology, 2004:, 2004. http://etd.gatech.edu/theses/available/etd-06072004-131158/unrestricted/heffner%5Fheather%5Fa%5F200405%5Fms.pdf.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Xu, Shuai. "PROMOTING BREAKTHROUGH MEDICAL INNOVATION: INSIGHTS FROM AN ANALYSIS OF RECENT TRANSFORMATIVE DRUGS, BIOLOGICS AND MEDICAL DEVICES." Thesis, Harvard University, 2014. http://etds.lib.harvard.edu/hms/admin/view/54.

Full text
Abstract:
Given the recent concern from multiple healthcare stakeholders that the pipeline of medical innovation is slowing, this thesis provides insights on how to spur breakthrough medical innovation in present day. The findings and recommendations are derived from one of the largest collections of interview transcripts from biomedical innovators (n=143) responsible for developing critical devices, drugs and diagnostics used in medicine today. An exemplary case (coronary artery stent) was selected for an in-depth analysis, which included a detailed recounting of stent development and an exhaustive a
APA, Harvard, Vancouver, ISO, and other styles
5

Eren, Ilke. "An Analysis Of Innovation And R&amp." Master's thesis, METU, 2010. http://etd.lib.metu.edu.tr/upload/12612851/index.pdf.

Full text
Abstract:
This thesis aims to explore the challenges of Medical Devices sector in their innovative activities with the use of qualitative and quantitative methods. The specific subject of analysis is the Turkish Medical Device industry. Throughout the thesis the convergence of Medical Devices with pharmacy and its role in healthcare is mentioned in addition to the institutional regulations of the sector due to their effect on the firms innovative activities. The main focus of this thesis is the innovation in medical devices as vital components of healthcare supply with an important share in health expe
APA, Harvard, Vancouver, ISO, and other styles
6

GOMES, LEILA CRISTINA NUNES. "PRODUCTION SYSTEMS IN THE MEDICAL IMAGE DEVICES INDUSTRY: AN ANALYSIS OF MAGNETIC RESONANCE." PONTIFÍCIA UNIVERSIDADE CATÓLICA DO RIO DE JANEIRO, 2004. http://www.maxwell.vrac.puc-rio.br/Busca_etds.php?strSecao=resultado&nrSeq=6081@1.

Full text
Abstract:
COORDENAÇÃO DE APERFEIÇOAMENTO DO PESSOAL DE ENSINO SUPERIOR<br>Nas últimas décadas, vem ocorrendo uma importante revolução na área da tecnologia médica, em particular nos equipamentos de diagnóstico por imagem. O propósito central da presente tese concentra-se na análise e compreensão das estratégias e sistemas produtivos empregados na produção desses equipamentos, com enfoque específico na produção de equipamentos de Ressonância Magnética, pela importância de se dispor de dados e informações principalmente em países como o Brasil que, apesar de ainda não apresentarem produção nacional
APA, Harvard, Vancouver, ISO, and other styles
7

AlEisa, Abdulaziz A. (Abdulaziz Asaad). "Production system improvement at a medical devices company : floor layout reduction and manpower analysis." Thesis, Massachusetts Institute of Technology, 2012. http://hdl.handle.net/1721.1/78160.

Full text
Abstract:
Thesis (M. Eng. in Manufacturing)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2012.<br>"September 2012." Cataloged from PDF version of thesis.<br>Includes bibliographical references (p. 84).<br>Due to the low demand and the need to introduce other production lines in the floor, the medical devices company wants to optimize the utilization of space and manpower for the occlusion system product. This thesis shows the approaches and methodology used to reduce the occlusion system's floor area from 1528 ft² to 1052 ft². Also, it provides a detailed analysis of the manp
APA, Harvard, Vancouver, ISO, and other styles
8

Jedryszek, Jakub. "A model-driven development and verification approach for medical devices." Thesis, Kansas State University, 2014. http://hdl.handle.net/2097/18222.

Full text
Abstract:
Master of Science<br>Department of Computing and Information Sciences<br>John Hatcliff<br>Medical devices are safety-critical systems whose failure may put human life in danger. They are becoming more advanced and thus more complex. This leads to bigger and more complicated code-bases that are hard to maintain and verify. Model-driven development provides high-level and abstract description of the system in the form of models that omit details, which are not relevant during the design phase. This allows for certain types of verification and hazard analysis to be performed on the models. These
APA, Harvard, Vancouver, ISO, and other styles
9

Venson, José Eduardo. "Medical image analysis based on mobile and virtual reality interfaces." reponame:Biblioteca Digital de Teses e Dissertações da UFRGS, 2017. http://hdl.handle.net/10183/165261.

Full text
Abstract:
A radiologia é especialidade médica mais informatizada, graças a difusão de protocolos e a digitalização dos processos. Com os avanços da tecnologia, o diagnóstico por imagens se mantém em constante evolução e tais mudanças nunca tiveram tanta repercussão sobre o trabalho dor profissionais de saúde como agora. Nosso desafio enquanto pesquisadores de computação é propor abordagens que facilitem o trabalho médico, instigue a colaboração e, por fim, como objetivo mais audacioso, melhore os cuidados à saúde das pessoas. Nesse contexto, esta dissertação investiga a inserção de interfaces alternativ
APA, Harvard, Vancouver, ISO, and other styles
10

Chang, David Wei-Péng. "ST. JUDE MEDICAL: PULMONARY EDEMA MONITORING IN PACEMAKERS AND ICDS." DigitalCommons@CalPoly, 2013. https://digitalcommons.calpoly.edu/theses/1112.

Full text
Abstract:
Pulmonary edema occurs when fluid leaks from the pulmonary capillary network into the lung interstitium and alveoli. When the heart is not able to pump blood to the body efficiently, fluid can back up into the veins that take blood through the lungs to the left atrium. This then builds up the pressure in the blood vessels and fluid is pushed into the alveoli in the lungs. The fluid reduces normal oxygen movement through the lungs and can cause impaired gas exchange and respiratory failure. There are many causes of congestive heart failure that may lead to pulmonary edema such as heart attack,
APA, Harvard, Vancouver, ISO, and other styles
11

León, Cerro Javier. "Advanced analysis of microelectronic devices and systems by lock-in IR thermography." Doctoral thesis, Universitat Autònoma de Barcelona, 2016. http://hdl.handle.net/10803/392687.

Full text
Abstract:
Desde los inicios de la revolución microelectrónica, su evolución tecnológica siempre se ha visto marcada por la búsqueda constante de dispositivos y sistemas electrónicos monolíticos más compactos, fiables y robustos, ofreciendo mejores prestaciones y funcionalidades a un coste razonable. Ello no sólo ha permitido su uso para complementar o sustituir en muchas aplicaciones a otros sistemas basados en elementos mecánicos, electromecánicos, hidráulicos, y neumáticos (sistemas de comunicación, more electric aircrafts o tracción ferroviaria), sino que también ha dado lugar a nuevos conceptos o ca
APA, Harvard, Vancouver, ISO, and other styles
12

Lai, Rixin. "Analysis and Design for a High Power Density Three-Phase AC Converter Using SiC Devices." Diss., Virginia Tech, 2008. http://hdl.handle.net/10919/30155.

Full text
Abstract:
The development of high power density three-phase ac converter has been a hot topic in power electronics area due to the increasing needs in applications like electric vehicle, aircraft and aerospace, where light weight and/or low volume is usually a must. Many challenges exist due to the complicated correlations in a three-phase power converter system. In addition, with the emerging SiC device technology the operating frequency of the converter can be potentially pushed to the range from tens of kHz to hundreds of kHz at higher voltage and higher power conditions. The extended frequency range
APA, Harvard, Vancouver, ISO, and other styles
13

Nahar, Vikas. "Content based image retrieval for bio-medical images." Diss., Rolla, Mo. : Missouri University of Science and Technology, 2010. http://scholarsmine.mst.edu/thesis/pdf/Nahar_09007dcc80721e0b.pdf.

Full text
Abstract:
Thesis (M.S.)--Missouri University of Science and Technology, 2010.<br>Vita. The entire thesis text is included in file. Title from title screen of thesis/dissertation PDF file (viewed Dec. 23, 2009). Includes bibliographical references (p. 82-83).
APA, Harvard, Vancouver, ISO, and other styles
14

Mafina, Marc-Krystelle. "Novel fluorescent probes for analysis of protein interactions under truly physiological conditions with real medical devices." Thesis, Queen Mary, University of London, 2012. http://qmro.qmul.ac.uk/xmlui/handle/123456789/2972.

Full text
Abstract:
Protein adsorption under physiological conditions was recognised to be the key step in the modulation of biological responses between materials and an osseous environment. Many studies have shown variation of adsorption behaviour on medical materials but most experiments were performed under non-physiological idealised conditions with idealised samples. The aim of this thesis was to develop a method to analyse protein adsorption on real clinically relevant samples under physiologically relevant conditions. The use of fluorescent probes was identified as a methodology which would facilitate ana
APA, Harvard, Vancouver, ISO, and other styles
15

Zakucia, Jozef. "Metódy posudzovania spoľahlivosti zložitých elektronických systémov pre kozmické aplikácie." Doctoral thesis, Vysoké učení technické v Brně. Fakulta strojního inženýrství, 2015. http://www.nusl.cz/ntk/nusl-234213.

Full text
Abstract:
This thesis deals with a common cause failure analysis (CCF) for space devices. This analysis belongs among dependability analyses, which have not been sufficiently developed in a field of space industry in corresponding technical and normative documents. Therefore, we focused on devising a new procedure of a qualitative and quantitative common cause failure analysis for the space applications herein. This new procedure of the qualitative and quantitative CCF analysis was applied on redundant systems of a special space device microaccelerometer (ACC), which was developed in VZLÚ. Performance o
APA, Harvard, Vancouver, ISO, and other styles
16

Yates, Madeleine Rebecca. "An analysis of the environmental impacts of plastic single-use medical device disposal in hospitals in England." Thesis, University of Cambridge, 2015. https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.708569.

Full text
APA, Harvard, Vancouver, ISO, and other styles
17

Stenberg, Mattias. "Concept design and In Vitro evaluation of a novel dynamic displacement Ventricular Assist Device." Licentiate thesis, Stockholm : KTH Technology and Health, 2006. http://www.diva-portal.org/kth/theses/abstract.xsql?dbid=3991.

Full text
APA, Harvard, Vancouver, ISO, and other styles
18

Said, J. F. S. "The application of static and flow-through isothermal microcalorimetry to the antimicrobial analysis of medical materials and devices." Thesis, University College London (University of London), 2014. http://discovery.ucl.ac.uk/1451950/.

Full text
Abstract:
In the light of problematic challenges in assessing the antimicrobial properties of medical materials and devices it is necessary and important to explore novel applications of existing analytical techniques. Isothermal microcalorimetry, whether as a static or modified flow-through system, was shown to have great potential with this area. The growth and metabolism of microbes, as with any other process, involves a change in enthalpy (heat). This is measurable using isothermal microcalorimetry, allowing real-time detection of growth and changes in metabolic performance of microorganisms. While
APA, Harvard, Vancouver, ISO, and other styles
19

Boostandoost, Mahyar [Verfasser], and Christian [Akademischer Betreuer] Boit. "Signature of Photon Emission and Laser Stimulation for Failure Analysis of Semiconductor Devices with respect to Thin-Film Solar Cells / Mahyar Boostandoost. Betreuer: Christian Boit." Berlin : Technische Universität Berlin, 2013. http://d-nb.info/1065148127/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
20

Jones-Dozier, Shelby L. "Proteomic Analysis of the Response of Pseudomonas Aeruginosa PAO1 to the Cell to Cell Signaling Molecule Trans, Trans-farnesol of Candida Albicans." Digital Archive @ GSU, 2008. http://digitalarchive.gsu.edu/biology_diss/84.

Full text
Abstract:
Nosocomial infections associated with implanted medical- devices are on the rise due to a growing immunocompromised patient population. The organisms of interest in this study are Pseudomonas aeruginosa and Candida albicans. These organisms are opportunistic pathogens and are frequently implicated as the cause of infection and colonization of medical devices. P. aeruginosa is a motile gram-negative bacterium that is able to suppress the growth of C. albicans. Quourm sensing mimicry and biofilm formation on the hyphal surface of C. albicans by P. aeruginosa aids in suppression. C. albicans is a
APA, Harvard, Vancouver, ISO, and other styles
21

Garner, Robin S. "A Comparative Analysis of Data Collection Systems Used in Radiography Educational Programs and the Role Mobile Electronic Devices Play." Digital Commons @ East Tennessee State University, 2015. https://dc.etsu.edu/etd/2592.

Full text
Abstract:
Each radiography program has a system to collect important data from didactic and clinical settings in order to accurately assess the progress and success of students, provide the needed student intervention, and provide accreditation agencies with appropriate documentation that demonstrates student success in reaching program learning outcomes. The purpose of this research study was to determine the method of data collection and documentation used by radiography programs to evaluate student progress and to examine if MEDs play a role in evaluating and documenting student skills at the point o
APA, Harvard, Vancouver, ISO, and other styles
22

Nycz, Christopher Julius. "Modeling & Analysis of Design Parameters for Portable Hand Orthoses to Assist Upper Motor Neuron Syndrome Impairments and Prototype Design." Digital WPI, 2018. https://digitalcommons.wpi.edu/etd-dissertations/501.

Full text
Abstract:
Wearable assistive robotics have the potential to address an unmet medical need of reducing disability in individuals with chronic hand impairments due to neurological trauma. Despite myriad prior works, few patients have seen the benefits of such devices. Following application experience with tendon-actuated soft robotic gloves and a collaborator's orthosis with novel flat-spring actuators, we identified two common assumptions regarding hand orthosis design. The first was reliance on incomplete studies of grasping forces during activities of daily living as a basis for design criteria, leadin
APA, Harvard, Vancouver, ISO, and other styles
23

Sadik, Diane-Perle. "On Reliability of SiC Power Devices in Power Electronics." Doctoral thesis, KTH, Elkraftteknik, 2017. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-207763.

Full text
Abstract:
Silicon Carbide (SiC) is a wide-bandgap (WBG) semiconductor materialwhich has several advantages such as higher maximum electric field, lowerON-state resistance, higher switching speeds, and higher maximum allowablejunction operation temperature compared to Silicon (Si). In the 1.2 kV - 1.7kV voltage range, power devices in SiC are foreseen to replace Si Insulatedgatebipolar transistors (IGBTs) for applications targeting high efficiency,high operation temperatures and/or volume reductions. In particular, theSiC Metal-oxide semiconductor field-effect transistor (MOSFET) – which isvoltage contro
APA, Harvard, Vancouver, ISO, and other styles
24

Blanco, Lucena Francisco. "Chemical speciation on urinary lithiasis. Image analysis and separation techniques for the study of lithogenesis." Doctoral thesis, Universitat Autònoma de Barcelona, 2014. http://hdl.handle.net/10803/285557.

Full text
Abstract:
La formació de concrecions sòlides al tracte urinari, malaltia que rep el nom de litiasi urinària, és un desordre molt comú arreu del món. La seva taxa de incidència és del 12% a la població mundial, i la de recurrència (repetició d’episodis litiàsics) és del 50%. Els recursos destinats al tractament de la litiasi urinària suposen una important llast als pressupostos de la sanitat pública. Els reptes que fixa aquesta malaltia requereixen opcions més avançades de diagnòstic i tractament. Existeix una necessitat clara a la comunitat mèdica (i a la societat) de reduir les elevades taxes d’incidèn
APA, Harvard, Vancouver, ISO, and other styles
25

Liljeroos, Maria. "Caring needs in patient-partner dyads affected by heart failure : An evaluation of the long-term effects of a dyadic psycho-educational intervention." Doctoral thesis, Linköpings universitet, Avdelningen för omvårdnad, 2017. http://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-133182.

Full text
Abstract:
Introduction: As medical treatment has improved, patients with heart failure (HF) now live longer and care mostly takes place at home with partners providing the main assistance. Taking care of an ill or disabled individual imposes a well-documented burden on the partner’s healthrelated quality of life. The awareness of partners’ burdensome situation is increasing, but few interventions have targeted the needs of patientpartner dyads with HF. The results have been inconclusive and give no clear guidance on how interventional programmes should be designed to improve both patient and partner out
APA, Harvard, Vancouver, ISO, and other styles
26

Sánchez, Martínez Sergio. "Multi-feature machine learning analysis for an improved characterization of the cardiac mechanics." Doctoral thesis, Universitat Pompeu Fabra, 2018. http://hdl.handle.net/10803/663748.

Full text
Abstract:
This thesis focuses on the development of machine learning tools to better characterize the cardiac anatomy and function in the context of heart failure, and in particular their extension to consider multiple parameters that help identifying the pathophysiological aspects underlying disease. This advanced and personalized characterization may eventually allow assigning patients to clinically-meaningful phenogroups with a uniform treatment response and/or disease prognosis. Specifically, the thesis copes with the technical difficulties that multivariate analyses imply, paying special attention
APA, Harvard, Vancouver, ISO, and other styles
27

Richardson, Kevin Thomas. "DESIGN AND ANALYSIS OF A 3D-PRINTED, THERMOPLASTIC ELASTOMER (TPE) SPRING ELEMENT FOR USE IN CORRECTIVE HAND ORTHOTICS." UKnowledge, 2018. https://uknowledge.uky.edu/me_etds/127.

Full text
Abstract:
This thesis proposes an algorithm that determine the geometry of 3D-printed, custom-designed spring element bands made of thermoplastic elastomer (TPE) for use in a wearable orthotic device to aid in the physical therapy of a human hand exhibiting spasticity after stroke. Each finger of the hand is modeled as a mechanical system consisting of a triple-rod pendulum with nonlinear stiffness at each joint and forces applied at the attachment point of each flexor muscle. The system is assumed quasi-static, which leads to a torque balance between the flexor tendons in the hand, joint stiffness and
APA, Harvard, Vancouver, ISO, and other styles
28

Cunha, Renato Barbosa da. "Estudo comparativo da eficiência de territórios de venda de dispositivos médicos através de modelo de Análise Envoltória de Dados (DEA)." reponame:Biblioteca Digital de Teses e Dissertações da UFRGS, 2014. http://hdl.handle.net/10183/111799.

Full text
Abstract:
Com o aumento da capacidade de processamento de dados dentro das empresas de todos os portes e da disponibilidade de informações cada vez maior nos tempos atuais, o uso de indicadores e ferramentas de análise quantitativa tornam-se cada vez mais comuns nas mais diversas áreas, buscando-se eficiência, uma correta alocação de recursos e na geração de expectativas mais realistas de vendas e resultados. Enquanto muitos mercados apresentam uma variedade de dados e de estudos para serem usados como bases de referência, existem outros que ainda são carentes de informações básicas para planejamento e
APA, Harvard, Vancouver, ISO, and other styles
29

Chalon, Antoine. "Développement d’un dispositif médical implantable d’assistance ventriculaire par compression cardiaque directe : l’exosquelette cardiaque." Thesis, Université de Lorraine, 2018. http://www.theses.fr/2018LORR0313.

Full text
Abstract:
L’assistance ventriculaire constitue une voie thérapeutique prometteuse de l’insuffisance cardiaque terminale. En dépit des progrès, notamment dans le développement des assistances de type shunt ventriculo-aortique, les écueils relatifs à l’encombrement, à l’alimentation et/ou aux interactions avec le sang de ces dispositifs limitent leur application clinique. Récemment, le concept de Compression Cardiaque Directe (DCC) apparaît comme une piste prometteuse en palliant les difficultés sus-citées. Dans ce travail de thèse, nous avons mis l’accent sur la conception et le test de faisabilité d’une
APA, Harvard, Vancouver, ISO, and other styles
30

Tokhadzé, Nicolas. "Etude des phénomènes de sorption entre médicaments et dispositifs médicaux de la perfusion : approche empirique et fondamentale par simulation moléculaire." Thesis, Université Clermont Auvergne‎ (2017-2020), 2020. http://www.theses.fr/2020CLFAC006.

Full text
Abstract:
Lors de la perfusion de médicaments via des dispositifs médicaux (DM) à base de matériaux polymères, des phénomènes de sorption peuvent entrainer une perte de principe actif (PA) et donc le risque de ne pas administrer la bonne dose au patient, induisant ainsi une diminution voire une perte de l’activité thérapeutique. Le but de ce travail était dans un premier temps d’étudier expérimentalement les interactions de trois PA (diazépam, paracétamol et insuline) avec des DM isolés et avec des DM au sein d’un montage complet de perfusion composé d’une seringue, d’un prolongateur et d’un cathéter. L
APA, Harvard, Vancouver, ISO, and other styles
31

Souza, Mara Clécia Dantas. "Regulação sanitária de produtos para a saúde no Brasil e no Reino Unido: o caso dos equipamentos eletromédicos." Programa de pós-graduação em saúde coletiva, 2007. http://www.repositorio.ufba.br/ri/handle/ri/10412.

Full text
Abstract:
p. 1-290<br>Submitted by Santiago Fabio (fabio.ssantiago@hotmail.com) on 2013-04-30T20:35:03Z No. of bitstreams: 1 3333333333333333.pdf: 2022341 bytes, checksum: 509258a28eae8740edd814fa04c095a7 (MD5)<br>Approved for entry into archive by Maria Creuza Silva(mariakreuza@yahoo.com.br) on 2013-05-04T17:41:44Z (GMT) No. of bitstreams: 1 3333333333333333.pdf: 2022341 bytes, checksum: 509258a28eae8740edd814fa04c095a7 (MD5)<br>Made available in DSpace on 2013-05-04T17:41:44Z (GMT). No. of bitstreams: 1 3333333333333333.pdf: 2022341 bytes, checksum: 509258a28eae8740edd814fa04c095a7 (MD5) Previous is
APA, Harvard, Vancouver, ISO, and other styles
32

Heleno, Bruno da Costa. "Aplicação da manutenção centrada na fiabilidade a dispositivos médicos." Master's thesis, 2014. http://hdl.handle.net/10400.14/17422.

Full text
Abstract:
A generalidade dos estabelecimentos de prestação de cuidados de saúde é de opinião de que os custos de manutenção dos equipamentos médicos de sua propriedade são demasiado elevados. É também conhecida a ausência de procedimentos rigorosos visando a certificação da calibração e do desempenho adequado dos instrumentos de medida, comprometendo assim a segurança dos profissionais da saúde e até mesmo dos utentes. A gestão da manutenção de dispositivos médicos surge como uma ferramenta fundamental para garantir níveis elevados de fiabilidade, disponibilidade, segurança e eficiência técnica e econó
APA, Harvard, Vancouver, ISO, and other styles
33

Gan, Tsuey Hwa, and 甘翠華. "Study of failure analysis method and failure model for electronic devices." Thesis, 2004. http://ndltd.ncl.edu.tw/handle/38773973322509690450.

Full text
Abstract:
碩士<br>元智大學<br>電機工程學系<br>92<br>The main purpose of failure analysis is used to assist the designers and manufacturers to analyze the factors of failure of an element and explore the solutions in order to improve the quality of the products and rise the compete ability of the industry. Therefore, how effectively to execute the failure analysis and constructing the related procedures are the main goals of this study. The present works were concentrated on the failure analysis method of the electronic devices and the construction of the failure model. The major work includes the procedu
APA, Harvard, Vancouver, ISO, and other styles
34

Taghipour, Sharareh. "Reliability and Maintenance of Medical Devices." Thesis, 2011. http://hdl.handle.net/1807/29886.

Full text
Abstract:
For decades, reliability engineering techniques have been successfully applied in many industries to improve the performance of equipment maintenance management. Numerous inspection and optimization models are developed and widely used to achieve maintenance excellence, i.e. the balance of performance, risk, resources and cost to reach to an optimal solution. However, the application of all these techniques and models to medical devices is new. Hospitals, due to possessing a large number of difference devices, can benefit significantly if the optimization techniques are used properly in the eq
APA, Harvard, Vancouver, ISO, and other styles
35

Tsai, Cheng-Tsun, and 蔡政村. "Combination of electrical probing and microscope inspection for failure analysis of semiconductor devices." Thesis, 2014. http://ndltd.ncl.edu.tw/handle/rbr34g.

Full text
Abstract:
碩士<br>國立交通大學<br>工學院半導體材料與製程設備學程<br>102<br>This study was focused on failure analysis for custom product with end terminal production return. Because there is only one or two sample from board level return, the priority of this case event is emergent for tracing all the effecting reason. We propose an efficient way to short the analysis time and develop a failure analysis scheme to fit custom requirement. In this thesis, we report the combination of electrical probing and photo emission microscope techniques. As to the surface mount technology (SMT) response, this system was demonstrated the ab
APA, Harvard, Vancouver, ISO, and other styles
36

Wu, Hui-feng, and 吳惠鳳. "Applying Healthcare Failure Mode and Effect Analysis to Assurance of Sterilization for Medical Materials." Thesis, 2012. http://ndltd.ncl.edu.tw/handle/dgca9q.

Full text
Abstract:
碩士<br>嘉南藥理科技大學<br>醫務管理系<br>100<br>Whereas the medical establishments are paying more and more attention to the medical care mode of patient-oriented, it becomes an important subject in management of medical quality to avoid the occurrence of patient’s safety accident by risk management, while the Healthcare Failure Mode and Effect Analysis (HFMEA) is a risk management method for predictive and preventive to search and correct any risky element in the procedures of highly risky care. In this study, HFMEA was used to assess the mode of potential failure and its causes in validation of sterilizat
APA, Harvard, Vancouver, ISO, and other styles
37

Kuo, Shu Chen, and 郭淑珍. "Medical service failure and trend analysis: Evidence from the judgments delivered from district courts." Thesis, 2016. http://ndltd.ncl.edu.tw/handle/v69mev.

Full text
Abstract:
博士<br>亞洲大學<br>經營管理學系<br>104<br>As the cases of medical malpractice derived from the failure of medical service, both domestically and abroad alike, increased as the days go by. Therefore, how to prevent medical errors is an important issue.Past studies rarely emphasized medical service failure (MSF) based on patients’ viewpoint and also rarely developed prevention strategies based on patients’ perspective. The objective of this research is to analyze the Judicial Legal Information Retrieval System of Medical Malpractice verdict, to discuss the categories of medical failure that took place base
APA, Harvard, Vancouver, ISO, and other styles
38

Chen, Mei-Ning, and 陳梅寧. "Aesthetic Medical Devices Company Operations Planning and Strategic Analysis Exemplified by G company." Thesis, 2015. http://ndltd.ncl.edu.tw/handle/swd6z2.

Full text
Abstract:
碩士<br>輔仁大學<br>企業管理學系管理學碩士在職專班<br>103<br>The aesthetic market carrying big opportunity into Taiwan, it’s also highly correlated with many medical instrument distributor or company. Taiwan aesthetic market is around 900 million USD/Yr, it’s concluded cosmeceutical products, laser or energy base devices, fillers, neuron toxins, and plastic surgery. And the growth rate is 30% per year. The main purpose of this research is try to find out a new business model in this compact aesthetic market. From beginning, consumers keep invent money for beauty, clinics and pharmaceutical company join the big war
APA, Harvard, Vancouver, ISO, and other styles
39

Fan, Yao-Jen, and 范耀仁. "Using Healthcare Failure Mode and Effect Analysis and Root Cause Analysis to Evaluate the Risk of Medical Services." Thesis, 2014. http://ndltd.ncl.edu.tw/handle/50636098647361354890.

Full text
Abstract:
碩士<br>開南大學<br>商學院碩士在職專班<br>102<br>The main purpose of this study, with combination of an improving method, known as Healthcare Failure Mode and Effect Analysis (HFMEA), and another method, known as Root Cause Analysis (RCA), to analyze the clinical adverse events, sort out the potential risk factors and understand the main causes of the accidents happening during hospitalization, with a great hope to provide an effect and better solution. We organised a group of medical staffs for quality management for patient safety, with main regards to medical adverse events in our hospital, which was a re
APA, Harvard, Vancouver, ISO, and other styles
40

Song, Yuqi. "Rhinitis radiofrequency ablation: FEM analysis and experiments." Thesis, 2018. http://hdl.handle.net/2097/39132.

Full text
Abstract:
Master of Science<br>Department of Electrical and Computer Engineering<br>Punit Prakash<br>The primary objective of this research is to implement an experimentally validated computational model to guide device design and selection of energy delivery strategies for treating chronic rhinitis by radiofrequency ablation. Chronic rhinitis is one of the most common global health problems. It is not life-threatening but has a severe impact on quality of life. Direct cost by chronic rhinitis is enormous and places a burden on societies. Radiofrequency ablation is proposed to be as an efficient treatme
APA, Harvard, Vancouver, ISO, and other styles
41

LUNG, CHUNG KAI, and 鍾凱隆. "The Hot Forged Process Parameters Analysis of Co-Cr-Mo Alloy for Medical Devices." Thesis, 2013. http://ndltd.ncl.edu.tw/handle/n2j8v3.

Full text
Abstract:
碩士<br>正修科技大學<br>機電工程研究所<br>101<br>Cobalt-chromium-molybdenum (CCM) alloy due to good mechanical properties, abrasion resistance and excellent corrosion resistance, has been widely used in orthopedic implant materials. CCM alloy forming is hard to use of cold forging process, so the industry mainly uses the hot forging technology. In order to analysis the effect of the forging preheat temperature on the CCM alloy material properties, the preheat temperature level was evaluated as a parameter in this study to carry out the most suitable preheat temperature of CCM alloy hot forging process for o
APA, Harvard, Vancouver, ISO, and other styles
42

Huang, Ching-Hung, and 黃景宏. "The strategic analysis of Taiwan medical devices entering Thailand market ( Dbi company as an sample)." Thesis, 2018. http://ndltd.ncl.edu.tw/handle/mcx5dh.

Full text
APA, Harvard, Vancouver, ISO, and other styles
43

Lin, Kuen-Huei, and 林坤輝. "Competitive strategic analysis and suggestion--A study on a new corporate of orthopedic medical devices." Thesis, 2013. http://ndltd.ncl.edu.tw/handle/48828113790590060511.

Full text
Abstract:
碩士<br>國立臺灣大學<br>商學組<br>101<br>Owing to the implement of national insurance project, increasing number of aging people and more demand of life quality in Taiwan, the need for medical resources will keep in stable growth and promote the growth of medical devices market. Companying with increasing of medical expenses, the government administers some policies to reduce the negative influences of economic burden and control the growing of medical expenses, such as global budgets, reducing the prices of drugs, medical devices and diagnosis related groups(DRGs). These policies will restrict the growi
APA, Harvard, Vancouver, ISO, and other styles
44

Perng, Chung Chin, and 彭忠清. "Using Healthcare Failure Mode & Effect Analysis-An Example of Supply Safety in Maintenance Medical Gas(O2)." Thesis, 2011. http://ndltd.ncl.edu.tw/handle/54342120215213453710.

Full text
Abstract:
碩士<br>聖約翰科技大學<br>自動化及機電整合研究所<br>99<br>From the viewpoint of health, “Prevention is better than treatment.” From the viewpoint of a matter, “Prevent beforehand is better than remedy afterward.” Both of them are the conception of risk management. Then the healthcare failure mode and effect analysis (HFMEA) are the methods of risk management, which is used by the Joint Commission on Accreditation of Healthcare Organizations (JCAHO) to support the healthcare industry to analyze and evaluate. The healthcare failure mode and effect analysis are a kind of pre-action style risk management, which is a
APA, Harvard, Vancouver, ISO, and other styles
45

Yeh, Yu-han, and 葉又菡. "Using Health Failure Modes and Effects Analysis to establish the precautionary Mechanism of Clinical Laboratory Medical Errors." Thesis, 2008. http://ndltd.ncl.edu.tw/handle/24090838772063610111.

Full text
Abstract:
碩士<br>雲林科技大學<br>工業工程與管理研究所碩士班<br>96<br>In recent years, many medical institutions have put their emphasis on the patient safety. Although, risk management like Failure Mode and Effect Analysis (FMEA) has been commonly practiced in the industry, it is rarely applied in the medical treatment. However American Joint Commission on Accreditation of Health Organizations (JCAHO) in 2003 recommended that each hospital should implement "Health Failure Modes and Effects Analysis (HFMEA)" for high risk medical treatment. The purpose of this study is using HFMEA to assess the potential risk factor of proc
APA, Harvard, Vancouver, ISO, and other styles
46

Chang, Hsiu-Lan, and 張秀蘭. "Analysis of Medical Resources Utilization for Patients with Renal Failure before Dialysis Therapy--A Case Study of a Medical Center in Southern Taiwan." Thesis, 2008. http://ndltd.ncl.edu.tw/handle/00983735685103385466.

Full text
Abstract:
碩士<br>長榮大學<br>醫務管理學系碩士班<br>96<br>Motivation According to statistics from Department of Health, nephritis and kidney disease have always been on the list of top ten causes of death for years (they are the seventh leading cause of death in 2003 and 2004). Chronic kidney disease is ranked number eight so far, with an increase of death rate from 11.39% every 100,000 people in 1990 to 20.7% in 2004. Every year the Bureau of National Health Insurance spends as much as 24.5 billion dollars on dialysis patients. There are about eight to night thousand new patients that need to receive dialysis therapy
APA, Harvard, Vancouver, ISO, and other styles
47

SU-JU, WU, and 吳叔如. "An Implementation of Failure Mode and Effects Analysis in Surgery Safe- A Case Study of a Medical Center." Thesis, 2016. http://ndltd.ncl.edu.tw/handle/j52czb.

Full text
Abstract:
碩士<br>東海大學<br>工業工程與經營資訊學系<br>104<br>A surgical procedure the medical team, the entire process to the medical team as the main instrument with a variety of other auxiliary equipment and other items to complete the operation. Medical unit operating room are high-risk units, so patient safety is the focus of surgery, surgical procedures in hospitals likely risk process can take place in advance is prevention. In this study, failure mode and effects analysis (HFMEA) Risk Priority Index (RPN), to assess the potential failure factors causing injury during surgery, and then propose preventive measure
APA, Harvard, Vancouver, ISO, and other styles
48

Chang, Li-Yung, and 鄭麗雲. "The Strategies Formulation Analysis of the Medical Devices Manufacture in Taiwan. - A Case Study of Company D." Thesis, 2008. http://ndltd.ncl.edu.tw/handle/93mb4g.

Full text
Abstract:
碩士<br>淡江大學<br>國際貿易學系國際企業學碩士在職專班<br>96<br>By the change of human life-span and population structure and following the brilliant progress of technological and information transmission, people pay more attention on personal healthcare and medical treatment matters. The medical devices industry of Taiwan is in middle-small scale because of the small market. Besides, the peripheral industry of supporting each other is insufficient, make the scale of the products expand slowly. However the electronic industry develops fast in recent years, make domestic electrical medical devices manufacturing obvio
APA, Harvard, Vancouver, ISO, and other styles
49

Hsieh, Uiong-Zoei, and 謝泳叡. "The Verification and Validation of Software Contained in the Medical Devices: The Example of Cephalometric Analysis System." Thesis, 2008. http://ndltd.ncl.edu.tw/handle/38902362699493364479.

Full text
Abstract:
碩士<br>南台科技大學<br>電機工程系<br>96<br>The failures of medical device might cause hazard to patients or operators. So, the software contained in a medical device should be verified and validated to insure the safety and the quality. Software engineering practices, risk analysis and management, and configuration management should be integrated in the study of software verification and validation (SV&V). Those approaches are acceptable by the FDA for the SV&V. In this work, the V-model was introduced in the software development process for the quality management of software development. The fault tree a
APA, Harvard, Vancouver, ISO, and other styles
50

Tsai, Wei-Jen, and 蔡維仁. "Application of Failure Analysis Method for Medical Logistical Management – Case Study on the Central Control and Monitor System of a Medical Center in Central Taiwan." Thesis, 2008. http://ndltd.ncl.edu.tw/handle/27968637663804803596.

Full text
Abstract:
碩士<br>大葉大學<br>工業工程與科技管理學系碩士在職專班<br>96<br>The central control and monitor system can collect the alarming signals from its subsystems. All the collected alarming signals need further investigation to identify the cause of the associated accident. Hence establishing problem tracing schemes which can detect the real causes of the accident is an important issue. With the knowledge of the factors causing the problem, the number of the accidents or failure events can be reduced. In this research, a new integrated methodology of failure mode and effects analysis is presented to analyze the data colle
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!