To see the other types of publications on this topic, follow the link: Fault Ride Through.

Dissertations / Theses on the topic 'Fault Ride Through'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 35 dissertations / theses for your research on the topic 'Fault Ride Through.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.

1

Mishra, Navin. "Analysis of fault ride through disturbances in wind energy." Thesis, Högskolan i Halmstad, 2019. http://urn.kb.se/resolve?urn=urn:nbn:se:hh:diva-40474.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Morshed, Mohammad Javad. "Fault Ride-Through Control Paradigms for DFIG-Based Wind Turbines." Thesis, University of Louisiana at Lafayette, 2019. http://pqdtopen.proquest.com/#viewpdf?dispub=10811697.

Full text
Abstract:
<p>This dissertation designs three different fault ride through (FRT) approaches to improve the performance of DFIG based WT during voltage sag conditions. First, an integral terminal sliding mode controller (ITSMC) was implemented for the rotor-side converter (RSC) and grid-side converter (GSC), and a fuzzy logic and a Posicast approach are also proposed to control the series grid side converter (SGSC). In the second approach, a fuzzy second order integral terminal sliding mode (FSOITSMC) approach for both RSC and GSC, along with a FSOITSMC-based Posicast controller for the SGSC, which is pla
APA, Harvard, Vancouver, ISO, and other styles
3

Feng, Yixue. "DC fault ride through operation of a full-bridge MMC converter." Thesis, University of Nottingham, 2016. http://eprints.nottingham.ac.uk/32426/.

Full text
Abstract:
In recent years the growth of renewable energy has encouraged the development of HVDC grids. One challenge of building HVDC grids is the power converter response to DC side faults. The full-bridge Modular Multilevel Converter (MMC) is a desired power converter topology which is used in HVDC grids due to its scalability, modularity and capability of blocking DC side faults. Post fault operation of the full-bridge MMC requires the control of power flow, the energy of each sub-module capacitor and the elimination of circulating harmonic current to reduce power loss while DC line-to-ground or DC l
APA, Harvard, Vancouver, ISO, and other styles
4

Pannell, Graham Steven. "Grid fault ride through for wind turbine doubly-fed induction generators." Thesis, University of Newcastle Upon Tyne, 2008. http://hdl.handle.net/10443/651.

Full text
Abstract:
Wind farms must contribute to the stability and reliability of the transmission grid, if they are to form a robust component of the electrical network. This includes providing grid support during grid faults, or voltage dips. Transmission system grid codes require wind farms to remain connected during specified voltage dips, and to supply active and reactive power into the network. Doubly-fed induction generator (DFIG) technology is presently dominant in the growing global market for wind power generation, due to the combination of variable-speed operation and a cost-effective partially-rated
APA, Harvard, Vancouver, ISO, and other styles
5

Causebrook, Andrew. "Fault ride-through of wind farms using series dynamic braking resistors." Thesis, University of Newcastle Upon Tyne, 2008. http://hdl.handle.net/10443/513.

Full text
Abstract:
Wind power is one of the world's fastest growing industries. The resulting penetration of wind power has led to substantial changes in requirements for large wind farms. Fault Ride-Through (FRT) was an important new requirement for wind farms to remain connected and actively contribute to system stability during a wide range of network faults. The wind industry responded with several approaches to FRT compliance including dynamic Reactive Power Compensation (dRPC) and pitch control. New requirements, combined with the reduced cost and increased efficiency of power electronic converters has led
APA, Harvard, Vancouver, ISO, and other styles
6

Söderström, Sebastian. "Simplified Model For Simulation of Fault Ride Through at Hydropower Units." Thesis, Uppsala universitet, Institutionen för fysik och astronomi, 2021. http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-445855.

Full text
Abstract:
As new requirements for grid connected generators were implemented, the requirements for evaluating the Fault Ride Through capabilities of the generators became stricter. When refurbishing a power unit, proof that the power unit meet the requirements must be submitted to the authorities. Performing simulations of the Fault Ride Through of a production unit is an extensive process and requires advanced simulation models and tools. Therefore, the need for a simplified tool for estimating the Fault Ride Through capability arose, which is what the project produced. Also, knowledge of which product
APA, Harvard, Vancouver, ISO, and other styles
7

Mendes, Victor Flores. "Ride-through fault capability improvement through novel control strategies applied for doubly-fed induction wind generators." Universidade Federal de Minas Gerais, 2013. http://hdl.handle.net/1843/BUOS-9UJQG7.

Full text
Abstract:
Due to the continuing growth of the installed power capacity of wind farms worldwide, the modern grid codes define specific requirements to the connection of wind turbines to the grid. One of these requirements is the ride-through fault capability, this is, the equipment capability of continuing operating during voltage sags. The grid codes require that, for some levels and duration of voltage sags, the equipment must not be disconnected from the grid and also supplies reactive power in order to contribute to network voltage stabilization. In this context, the present work analyze the behavior
APA, Harvard, Vancouver, ISO, and other styles
8

Koc, Erkan. "Modeling And Investigation Of Fault Ride Through Capability Of Variable Speed Wind Turbines." Master's thesis, METU, 2010. http://etd.lib.metu.edu.tr/upload/12612534/index.pdf.

Full text
Abstract:
Technological improvements on wind energy systems with governmental supports have increased the penetration level of wind power into the grid in recent years. The high level of penetration forces the wind turbines stay connected to the grid during the disturbances in order to enhance system stability. Moreover, power system operators must revise their grid codes in parallel with these developments. This work is devoted to the modeling of variable speed wind turbines and the investigation of fault ride trough capability of the wind turbines for grid integration studies. In the thesis, detail
APA, Harvard, Vancouver, ISO, and other styles
9

Meyer, Karl Robert [Verfasser]. "Fault-Ride-Through-Regelung von Windenergieanlagen mit Vollumrichter und LCL-Netzfilter / Karl Robert Meyer." Hannover : Technische Informationsbibliothek und Universitätsbibliothek Hannover (TIB), 2014. http://d-nb.info/1067588043/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Kendeck, Clement Ndjewel. "Fault ride-through capability of multi-pole permanent magnet synchronous generator for wind energy conversion system." Thesis, Cape Peninsula University of Technology, 2019. http://hdl.handle.net/20.500.11838/3060.

Full text
Abstract:
Thesis (MEng (Electrical Engineering))--Cape Peninsula University of Technology, 2019<br>Wind has become one of the renewable energy technologies with the fastest rate of growth. Consequently, global wind power generating capacity is also experiencing a tremendous increase. This tendency is expected to carry on as time goes by, with the continuously growing energy demand, the rise of fossil fuels costs combined to their scarcity, and most importantly pollution and climate change concerns. However, as the penetration level increases, instabilities in the power system are also more likely to occ
APA, Harvard, Vancouver, ISO, and other styles
11

Notholt, Vergara José Antonio. "Fault ride through capabilities of inverter based distributed generation connected to low and medium voltage distribution networks." München Verl. Dr. Hut, 2008. http://d-nb.info/992644887/04.

Full text
APA, Harvard, Vancouver, ISO, and other styles
12

Feltes, Christian [Verfasser]. "Advanced Fault Ride-Through Control of DFIG based Wind Turbines including Grid Connection via VSC-HVDC / Christian Feltes." Aachen : Shaker, 2012. http://d-nb.info/1069046019/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
13

Alsmadi, Yazan M. "Modeling, Advance Control, and Grid Integration of Large-Scale DFIG-Based Wind Turbines during Normal and Fault Ride-Through Conditions." The Ohio State University, 2015. http://rave.ohiolink.edu/etdc/view?acc_num=osu1437140573.

Full text
APA, Harvard, Vancouver, ISO, and other styles
14

Lei, Ting. "Doubly-fed induction generator wind turbine modelling, control and reliability." Thesis, University of Manchester, 2014. https://www.research.manchester.ac.uk/portal/en/theses/doublyfed-induction-generator-wind-turbine-modelling-control-and-reliability(2ceb051a-a6fb-43e6-be40-a5023dae4bea).html.

Full text
Abstract:
The trend of future wind farms moving further offshore requires much higher reliability for each wind turbine in order to reduce maintenance cost. The drive-train system and power electronic converter system have been identified as critical sub-assemblies that are subject to higher failure rates than the other sub-assemblies in a wind turbine. Modern condition monitoring techniques may help schedule the maintenance and reduce downtime. However, when it comes to offshore wind turbines, it is more crucial to reduce the failure rates (or reduce the stresses) for the wind turbines during operation
APA, Harvard, Vancouver, ISO, and other styles
15

Silva, Rafael Schincariol da 1983. "Desempenho de geradores distribuídos durante curtos-circuitos considerando requisitos de suportabilidade a afundamentos de tensão = Distributed generators performance during short-circuits considering fault ride-through requirements." [s.n.], 2012. http://repositorio.unicamp.br/jspui/handle/REPOSIP/259990.

Full text
Abstract:
Orientador: Walmir de Freitas Filho<br>Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação<br>Made available in DSpace on 2018-08-21T00:53:15Z (GMT). No. of bitstreams: 1 Silva_RafaelSchincariolda_M.pdf: 3440136 bytes, checksum: 042a03fcb6272566cfc1c79d07478e1c (MD5) Previous issue date: 2012<br>Resumo: O aumento da penetração de geradores em redes de distribuição de energia elétrica além de diversificar a matriz elétrica proporciona benefícios técnicos e econômicos. Contudo, também levanta preocupações relativas à confiabilidade no su
APA, Harvard, Vancouver, ISO, and other styles
16

Hjertberg, Tommy. "Fault energy implications of distributed converter interfaced generation : A case study of an underground mine grid." Thesis, KTH, Skolan för elektroteknik och datavetenskap (EECS), 2021. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-300903.

Full text
Abstract:
Adding Power Electronic Interfaced Devices (PEID) generation to grids is an increasing trend because of the concurrent development of better power electronic converters and a greater interest in a better utilisation of energy resources. Small and dispersed energy sources that would previously not be worth introducing into the grid is becoming more and more viable and other potential benefits such as better control of voltage levels and smoothing out load changes also spur this development. But while there are great potential benefits of the controllability of these devices there are also risks
APA, Harvard, Vancouver, ISO, and other styles
17

Bane, Popadić. "Napredno upravljanje pretvaračem povezanim na mrežu pri nesimetričnim naponskim prilikama u elektroenergetskom sistemu." Phd thesis, Univerzitet u Novom Sadu, Fakultet tehničkih nauka u Novom Sadu, 2019. https://www.cris.uns.ac.rs/record.jsf?recordId=107914&source=NDLTD&language=en.

Full text
Abstract:
U ovoj doktorskoj disertaciji razvijena je tehnika upravljanja zapretvarač energetske elektronike pri nesimetričnim naponskimprilikama u elektroenergetskom sistemu. Kao što je pokazano,primenom tehnike poništavanja signala kašnjenjem moguće jeizdvajanje komponenti struje inverznog redosleda i njihovopotpuno poništenje, što će omogućiti pouzdanu kontrolukomponenti struje direktnog redosleda upotrebom klasičnihtehnika upraljanja, uz adekvatno unapređenje tehnike zasinhronizaciju sa vektorskim reprezentom napona. Predloženaje i upotreba algoritama za poboljšanje parametara kvalitetaelektrične ene
APA, Harvard, Vancouver, ISO, and other styles
18

Najmi, Vahid. "Modeling, Control and Design Considerations for Modular Multilevel Converters." Thesis, Virginia Tech, 2015. http://hdl.handle.net/10919/53703.

Full text
Abstract:
This thesis provides insight into state-of-the-art Modular Multilevel Converters (MMC) for medium and high voltage applications. Modular Multilevel Converters have increased in interest in many industrial applications, as they offer the following advantages: modularity, scalability, reliability, distributed location of capacitors, etc. In this study, the modeling, control and design considerations of modular based multilevel converters, with an emphasis on the reliability of the converter, is carried out. Both modular multilevel converters with half-bridge and full-bridge sub-modules are evalu
APA, Harvard, Vancouver, ISO, and other styles
19

Hartono, Aryudha. "Microgrid Safety and Protection Strategies." Thesis, KTH, Elektroteknisk teori och konstruktion, 2018. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-226593.

Full text
Abstract:
One of the challenging issues with the Microgrid is that the bidirectional power flow providedby the distributed generator (DG) which modify the fault current level. Furthermore, theinverter based-renewable energy source (IB-RES) limits the total fault current contributionto the grid due to its thermal capability. Since Microgrid should be able to operate in gridconnectedand islanded mode, protection strategies are needed to solve this challenging issue.By only having IB-RES and battery storage system, the fault condition and normaloperation cannot be distinguished. Apart from fault clearing i
APA, Harvard, Vancouver, ISO, and other styles
20

Almeida, Pedro Machado de. "Contribuições ao estudo de conexão de sistemas fotovoltaicos à rede elétrica sem filtros passivos: projeto de controladores digitais para redução do conteúdo harmônico." Universidade Federal de Juiz de Fora (UFJF), 2013. https://repositorio.ufjf.br/jspui/handle/ufjf/4166.

Full text
Abstract:
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-04-24T19:07:44Z No. of bitstreams: 1 pedromachadodealmeida.pdf: 10367147 bytes, checksum: 04b7cf913c75cb9f82395bf7b9769825 (MD5)<br>Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-04-25T15:25:19Z (GMT) No. of bitstreams: 1 pedromachadodealmeida.pdf: 10367147 bytes, checksum: 04b7cf913c75cb9f82395bf7b9769825 (MD5)<br>Made available in DSpace on 2017-04-25T15:25:19Z (GMT). No. of bitstreams: 1 pedromachadodealmeida.pdf: 10367147 bytes, checksum: 04b7cf913c75cb9f82395bf7b9769825 (MD5) Previ
APA, Harvard, Vancouver, ISO, and other styles
21

Costa, Christielly Fernandes da. "Estudo da capacidade LVRT de sistemas eólicos com DFIG durante a ocorrência de faltas elétricas /." Bauru, 2020. http://hdl.handle.net/11449/192810.

Full text
Abstract:
Orientador: André Luiz Andreoli<br>Resumo: Nos últimos anos, questões relacionadas ao meio ambiente, principalmente, ao uso de combustíveis fósseis e à emissão de gases poluentes na atmosfera, ganharam grande destaque internacional. Com os avanços da comunidade científica e o aumento no preço do petróleo no começo da década de 1970, o uso de fontes renováveis, não poluentes e limpas teve grande investimento por parte de diversos países. Nesse contexto, a geração eólica vem se destacando como uma das mais promissoras, especialmente devido a sua viabilidade econômica e ao seu rápido desenvolvime
APA, Harvard, Vancouver, ISO, and other styles
22

Malik, Naveed ur Rehman. "Modelling, Analysis, and Control Aspects of a Rotating Power Electronic Brushless Doubly-Fed Induction Generator." Doctoral thesis, KTH, Elektrisk energiomvandling, 2015. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-174349.

Full text
Abstract:
This thesis deals with the modeling, analysis and control of a novel brushlessgenerator for wind power application. The generator is named as rotatingpower electronic brushless doubly-fed induction machine/generator (RPEBDFIM/G). A great advantage of the RPE-BDFIG is that the slip power recoveryis realized in a brushless manner. This is achieved by introducing an additionalmachine termed as exciter together with the rotating power electronicconverters, which are mounted on the shaft of a DFIG. It is shown that theexciter recovers the slip power in a mechanical manner, and delivers it backto th
APA, Harvard, Vancouver, ISO, and other styles
23

Lin, Kwan-Fu, and 林冠甫. "Fault Ride through Capability of Off-shore Wind Farm." Thesis, 2007. http://ndltd.ncl.edu.tw/handle/gt38hk.

Full text
Abstract:
碩士<br>國立中山大學<br>電機工程學系研究所<br>95<br>Large off-shore wind farms raise the concern of widespread tripping of off-shore wind generator in the presence of system faults and corresponding voltage dips that could potentially cause system wide blackout. In this thesis an offshore wind farm and three different types of power transmission are modeled and studied using simulation software. Off-shore wind farm composed of fixed speed induction generators and HVAC interconnection, HVAC interconnection plus STATCOM and HVDC interconnections are studied. Onshore grid faults are simulated for each interconnec
APA, Harvard, Vancouver, ISO, and other styles
24

Naderi, SB. "Improvement of fault ride through capability of wind turbines by fault current limiters." Thesis, 2018. https://eprints.utas.edu.au/28601/1/Naderi_whole_thesis_ex_pub_mat.pdf.

Full text
Abstract:
Due to increasing penetration levels of renewable energy in the power system, it is essential to keep renewable energy resources connected to the power grid during a fault considering the grid code requirements. In this thesis, the Fault Ride Through (FRT) capability of wind turbines is taken into account. All types of wind turbines are considered and for each one, the proposed methods will be discussed and studied. In the first approach for Fixed Speed Wind Turbines (FSWTs), to achieve maximum FRT capability, this thesis proposes a single-phase Optimum Resistive Type Fault Current Limiter (O
APA, Harvard, Vancouver, ISO, and other styles
25

ABOBKR, ABOBKR. "Fault Ride-Through Capability of Doubly-Fed Induction Generators Based Wind Turbines." 2013. http://hdl.handle.net/10222/21404.

Full text
Abstract:
Due to growing concerns over climate change, more and more countries are looking to renewable energy sources to generate electricity. Therefore, wind turbines are increasing in popularity, along with doubly-fed induction machines (DFIGs) used in generation mode. Current grids codes require DFIGs to provide voltage support during a grid fault. The fault ride-through (FRT) capability of DFIGs is the focus of this thesis, in which modifications to the DFIG controller have been proposed to improve the FRT capability. The static synchronous compensator (STATCOM) controller has been applied with pro
APA, Harvard, Vancouver, ISO, and other styles
26

Weng, Chi-Wei, and 翁啟維. "Fault Ride-Through Improvement of DFIG Using GTO-thyristor Controlled Series Resistor." Thesis, 2015. http://ndltd.ncl.edu.tw/handle/62923624123498704480.

Full text
Abstract:
碩士<br>國立臺灣大學<br>電機工程學研究所<br>103<br>Dynamic performance of a doubly-fed induction generator (DFIG) connected to a power system is investigated in this thesis. The overcurrent in the rotor side and the generator voltage dip in the stator side are studied. In order for the generator to be operated stably during the faulted period, an effective approach must be developed. In this thesis, GTO-thyristor Controlled Series Resistor (GCSR) is proposed to reduce the transient rotor current in the rotor side and increase the stator voltage and reduce the steady-state rotor current during the faulted peri
APA, Harvard, Vancouver, ISO, and other styles
27

Ramalho, Pedro Filipe Oliveira. "Parques eólicos com Ride-Through Fault : nova parametrização dos sistemas de protecção." Master's thesis, 2008. http://hdl.handle.net/10216/59657.

Full text
APA, Harvard, Vancouver, ISO, and other styles
28

Ramalho, Pedro Filipe Oliveira. "Parques eólicos com Ride-Through Fault : nova parametrização dos sistemas de protecção." Dissertação, 2008. http://hdl.handle.net/10216/59657.

Full text
APA, Harvard, Vancouver, ISO, and other styles
29

Lin, Yuan-Zheng, and 林員正. "Fault Ride Through Control of Doubly-Fed Induction Generators for Wind Power Applications." Thesis, 2009. http://ndltd.ncl.edu.tw/handle/90589258652600080762.

Full text
Abstract:
碩士<br>國立清華大學<br>電機工程學系<br>97<br>As the number of wind installations has grown worldwide at unprecedented rates in recent years, the average size of installations has increased due to the advent of larger capacity machine, variable speed technology, and an increasing number of off-shore sites. The raises the concern that widespread tripping of wind generators following disturbances could lead to propagation of transient instabilities and could potentially cause local or system wide blackouts. This has provoked many utilities to adopt fault ride-through (FRT) capability for wind turbines. This t
APA, Harvard, Vancouver, ISO, and other styles
30

Kish, Gregory. "Addressing Future Grid Requirements for Distributed Energy Resources." Thesis, 2011. http://hdl.handle.net/1807/31279.

Full text
Abstract:
This thesis first develops a medium-voltage grid code outlining stringent requirements for low-voltage ride-through, high-voltage ride-through and ancillary services based on anticipated grid requirements for distributed energy resources (DER)s. A 100 kW generating capacity DER study system is then formulated taking into consideration key design constraints as motivated by the medium-voltage grid code. Local DER system controls are developed that enable existing systems employing conventional current-control for the grid-interfacing voltage-sourced-converters to comply with the grid code. A su
APA, Harvard, Vancouver, ISO, and other styles
31

Swain, Snehaprava. "Development of Strategies for Fault Ride Through Capability Improvement of a Grid Connected DFIG based Wind Energy Conversion System." Thesis, 2019. http://ethesis.nitrkl.ac.in/10039/1/2019_PhD_SSnehaprava_513EE1010_Development.pdf.

Full text
Abstract:
Now-a-days, the growing demand of electricity and the scarcity of fossil fuels, encourage to generate electricity from never ending renewable energy resources such as wind, solar etc., Wind energy has become one of the most important and promising sources of renewable energy. Today the wind power capacity of the world is approximately 539,291 MW at the end of 2017 and around 52,552 MW of capacity was added in the year 2017 only. The rapid increase in wind farms and production of wind energy facilitates the interconnection of Wind Turbine Generation System (WTGS) with the grid for uninterruptab
APA, Harvard, Vancouver, ISO, and other styles
32

Silva, Bernardo Marques Amaral. "Parques eólicos com "Ride-Through Fault" : validação de um novo sistema de protecção em tempo real com ajuda do RTDS." Master's thesis, 2009. http://hdl.handle.net/10216/59199.

Full text
APA, Harvard, Vancouver, ISO, and other styles
33

Silva, Bernardo Marques Amaral. "Parques eólicos com "Ride-Through Fault" : validação de um novo sistema de protecção em tempo real com ajuda do RTDS." Dissertação, 2009. http://hdl.handle.net/10216/59199.

Full text
APA, Harvard, Vancouver, ISO, and other styles
34

Chowdhury, MM. "Modelling and control of direct drive variable speed wind turbine with Interior Permanent Magnet Synchronous Generator." Thesis, 2014. https://eprints.utas.edu.au/20844/1/Whole-Chowdhury-thesis.pdf.

Full text
Abstract:
The interest in wind energy system is growing worldwide to reduce dependency on fossil fuel and to minimize the adverse impact of climate change. Currently, doubly fed induction generator (DFIG) based variable speed wind turbine technology with gearbox is dominating the world market share. However, the problems associated with induction generator based wind turbines are reactive power consumption, mechanical stress and poor power quality. Moreover, the gearbox requires regular maintenance as it suffers from faults and malfunctions. Therefore, it is important to adopt technologies that ca
APA, Harvard, Vancouver, ISO, and other styles
35

Βρυώνης, Θεόδωρος. "Εφαρμογή τεχνικών υπολογιστικής νοημοσύνης για την αδιάλειπτη λειτουργία συστημάτων ηλεκτρικής ενέργειας με ανεμογεννήτριες σε διαταραχές βραχυκυκλωμάτων". Thesis, 2013. http://hdl.handle.net/10889/7514.

Full text
Abstract:
Στα πλαίσια της διδακτορικής διατριβής μελετήθηκε η αποτελεσματικότητα διαφόρων κυκλωμάτων ελέγχου που βασίζονται στην υπολογιστική νοημοσύνη με σκοπό την αντιμετώπιση βραχυκυκλωμάτων σε δίκτυα διασύνδεσης ανεμογεννητριών με το δίκτυο. Πιο συγκεκριμένα, τα προτεινόμενα συστήματα ελέγχου έχουν σκοπό τη διαμόρφωση κατάλληλων συνθηκών ώστε οι ανεμογεννήτριες να καταφέρουν να συνεχίσουν να είναι συνδεδεμένες στο δίκτυο κατά τη διάρκεια και αμέσως μετά τα βραχυκυκλώματα, συνεισφέροντας στη γρήγορη επαναφορά της τάσης στο Σημείο Κοινής Σύνδεσης με το Δίκτυο (ΣΚΣΔ). Στο πρώτο μέρος της διατριβής με
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!