Academic literature on the topic 'FIA method'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'FIA method.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "FIA method"

1

Carpenter, A. B., and C. D. Bartkowiak. "Rheumatoid factors determined by fluorescence immunoassay: comparison with qualitative and quantitative methods." Clinical Chemistry 35, no. 3 (1989): 464–66. http://dx.doi.org/10.1093/clinchem/35.3.464.

Full text
Abstract:
Abstract Fluorescence immunoassay (FIA), a relatively new technique for measuring rheumatoid factors (RF), is automated, quantitative, and calibrated against the Centers for Disease Control reference material for RF. We studied the FIA method in relation to a panel of RF methods, both qualitative [latex (LA) and sheep cell agglutination (SSCA)], and quantitative [nephelometry and enzyme-linked immunoassay (ELISA)]. Regression analysis revealed a highly significant correlation between FIA and either LA (r = 0.90) or nephelometry (r = 0.87). The correlation between FIA and either SSCA (r = 0.62)
APA, Harvard, Vancouver, ISO, and other styles
2

Motomizu, Shoji. "Computer-controlled fluid-flow chemical analysis (CC-FCA) and its application to environmental analytical chemistry." Pure and Applied Chemistry 84, no. 10 (2012): 1999–2013. http://dx.doi.org/10.1351/pac-con-12-02-09.

Full text
Abstract:
Computer-controlled fluid-flow chemical analysis (CC-FCA) was investigated for the determination of trace amounts of toxic pollutants in the environment. For CC-FCA, automated chemical analysis systems were developed by using computer-controllable pumping and valve modules, and polytetrafluorethylene (PTFE) tubing and connectors. The systems demonstrated in this work were a flow injection-type system, a sequential injection-type system, a mini-column pretreatment system (Auto-Pret system), and an Auto-Pret hyphenated with flow injection analysis (FIA) system. Such systems were fully controlled
APA, Harvard, Vancouver, ISO, and other styles
3

Sullivan, John J., Thomas A. Hollingworth, Marleen M. Wekell, et al. "Determination of Free (pH 2.2) Sulfite in Wines by Flow Injection Analysis: Collaborative Study." Journal of AOAC INTERNATIONAL 73, no. 2 (1990): 223–26. http://dx.doi.org/10.1093/jaoac/73.2.223.

Full text
Abstract:
Abstract A method for the determination of free sulfite In wine by flow injection analysis (FIA) is described. The method Involves liberation of sulfur dioxide from the wine at pH 2.2, with detection by decolorlzation of a malachite green solution. The method was collaboratively studied, and the results indicated an average reproducibility of 12% for white wine samples (average level 12.1 ppm S02) and 26% for red wine samples (average level 3.1 ppm). When the FIA method was compared to an aeration/oxidation method, the results Indicated a high degree of correlation between the 2 methods. The F
APA, Harvard, Vancouver, ISO, and other styles
4

Jericó, Márcia Marques, Berenice Bilharino de Mendonça, Mary Otsuka, Aristides Maganin Jr, and Carlos Eduardo Larsson. "NON-RADIOMETRIC IMMUNOASSAYS [FLUOROIMMUNOASSAY (FIA) AND FLUOROMETRIC ENZYME IMMUNOASSAY (FEIA)] WITH RADIOIMMUNOASSAY (RIA) FOR EVALUATION OF ADRENAL FUNCTION IN NORMAL AND HYPERCORTISOLEMIC DOGS." Ciência Rural 32, no. 2 (2002): 259–62. http://dx.doi.org/10.1590/s0103-84782002000200012.

Full text
Abstract:
Non-radiometric immunoassays offer many advantages over radiometric assays, such as higher stability of kit compounds and absence of potential hazardous effects for users and environment. The comparison of cortisol measurements by fluoroimmunoassay (FIA) and fluorometric enzyme immunoassay (FEIA) with radioimmunoassay (RIA) in adrenal function evaluation of normal (n=50) and hypercortisolemic dogs (n=12) was proposed. Serum concentrations of cortisol were measured in basal conditions and 8 hours after dexamethasone (DEX) suppression (0.01mg/kg/IV). All our reference values were based on the 5t
APA, Harvard, Vancouver, ISO, and other styles
5

Wang, Jing Fang. "Recursive PLS Modeling of Aromatics and Olefins in Gasoline." Advanced Materials Research 740 (August 2013): 267–72. http://dx.doi.org/10.4028/www.scientific.net/amr.740.267.

Full text
Abstract:
The separate calibration models of aromatics and olefins were established for gasoline through recursive partial least square (R-PLS) method in this paper.The some oil refining enterprise application has achieved better effect on the software being realized by R-PLS method. The calibration models were validated through comparison of the results determined by fluorescent indicator adsorption (FIA) and near infrared spectroscopy (NIR) methods.The NIR analysis results were well coincident with those of FIA method.The NIR can not only raise the analysis efficiency and lower the analysis cost,but a
APA, Harvard, Vancouver, ISO, and other styles
6

Campı́ns-Falcó, P., F. Bosch-Reig, and F. Blasco-Gómez. "Standard addition method in FIA. Comparison between different assemblies." Analytica Chimica Acta 379, no. 1-2 (1999): 89–97. http://dx.doi.org/10.1016/s0003-2670(98)00658-8.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Sullivan, John J., Thomas A. Hollingworth, Marleen M. Wekell, Richard T. Newton, and Jack E. Larose. "Determination of Sulfite in Food by Flow Injection Analysis." Journal of AOAC INTERNATIONAL 69, no. 3 (1986): 542–46. http://dx.doi.org/10.1093/jaoac/69.3.542.

Full text
Abstract:
Abstract A method is described for the determination of sulfite levels in food products by flow injection analysis (FIA). The method is based on the decolorization of malachite green by S02, which is isolated from the flowing sample stream by means of a gas diffusion cell. The FIA method has a detection limit in food sample extracts of 0.1 ppm S02 (3 times peak height of blank), which corresponds to 1-10 ppm S02 in a food product, depending on the extraction procedure used. At the 5 ppm SO2 level in a food extract, the precision of replicate injections is ± 1-2%. The method was tested on a var
APA, Harvard, Vancouver, ISO, and other styles
8

王, 效妍. "The Tax VAT Planning of Power Engineering Business from General Taxation Method Visual Angle." Frontiers of International Accounting 05, no. 04 (2016): 33–37. http://dx.doi.org/10.12677/fia.2016.54005.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Bendtsen, Anders Broe, and Søren Storgaard Jørgensen. "Determination of Total and Free Sulfite in Unstabilized Beer by Flow Injection Analysis." Journal of AOAC INTERNATIONAL 77, no. 4 (1994): 948–51. http://dx.doi.org/10.1093/jaoac/77.4.948.

Full text
Abstract:
Abstract The AOAC methods for the determination of total and free sulfite by flow injection analysis (FIA) were modified for the analysis of unstabilized beer. Suggested improvements to the methods include stabilizing the sulfite standards with EDTA, changing the FIA manifold to decrease the system dispersion, and using a nonlinear calibration curve. The modifications are simple to implement and provide a more stable, sensitive, and accurate method. The method for the determination of free sulfite is criticized, because the dynamic range of the method is very limited. Analysis of several beer
APA, Harvard, Vancouver, ISO, and other styles
10

Dekker, L., D. D. E. Zimmerman, R. M. Smeenk, R. Schouten, and I. J. M. Han-Geurts. "Management of cryptoglandular fistula-in-ano among gastrointestinal surgeons in the Netherlands." Techniques in Coloproctology 25, no. 6 (2021): 709–19. http://dx.doi.org/10.1007/s10151-021-02446-3.

Full text
Abstract:
Abstract Background Management of cryptoglandular fistula-in-ano (FIA) can be challenging. Despite Dutch and international guidelines determining optimal therapy is still quite difficult. The aim of this study was to report current practices in the management of cryptoglandular FIA among gastrointestinal surgeons in the Netherlands. Methods Dutch surgeons and residents who are treating FIA regularly were sent a survey invitation by email. The survey was available online from September 19 to December 1 2019. The questionnaire consisted of 28 questions concerning diagnostic and surgical techniqu
APA, Harvard, Vancouver, ISO, and other styles
More sources

Dissertations / Theses on the topic "FIA method"

1

Piškulová, Lenka. "Stanovení beta-glukanů a pentosanů v surovinách pro výrobu piva a v pivu." Master's thesis, Vysoké učení technické v Brně. Fakulta chemická, 2017. http://www.nusl.cz/ntk/nusl-295695.

Full text
Abstract:
The content of beta-glucans and arabinoxylans in barley grain, malt and wort was monitored. The varieties of barley were Pionier, Libuše, Manta, Tango, KWS Amadora, Kampa, KWS Irina, Francin, Odyssey, Overture, Vendela, Petrus, Laudis 550, Sunshine, Kangoo, Xanadu, Sebastian, Bojos and Malz. These varieties were grown on three different habitats (Uherský Ostroh, Věrovany and Vysoká u Příbramě). The content of beta-glucans and arabinoxylans was also analysed in five different types of beer. In brewing and malting industry the content of beta-glucans and arabinoxylans is mainly monitored because
APA, Harvard, Vancouver, ISO, and other styles
2

Donato, Adriana De. "Desenvolvimento, comparação e aplicação forense de sistemas de injeção em banho e injeção em fluxo, com detecção voltamétrica de chumbo em eletrodo de mercúrio." Universidade de São Paulo, 2001. http://www.teses.usp.br/teses/disponiveis/46/46133/tde-23112018-165441/.

Full text
Abstract:
Para determinar baixas concentrações de chumbo, oriundo de resíduos de disparo de armas de fogo, aplicou-se a voltametria de redissolução anódica, ASV, com pulso diferencial, PD, para detecção do metal em eletrodo de gota pendente de mercúrio, EGPM. A etapa de redução se dava a -0,6 V vs. Ag/AgCl, durante 25s, com imediata varredura até -0,3V vs. Ag/AgCl. O pico de reoxidação do chumbo surgia a -0,42V vs. Ag/AgCl. A injeção de amostras foi bastante facilitada pela aplicação do sistema de análise por injeção em banho, BIA onde um pequeno volume de amostra é injetado, com o auxílio de um micropi
APA, Harvard, Vancouver, ISO, and other styles
3

Höring, Marcus [Verfasser], and Gerhard [Akademischer Betreuer] Liebisch. "Development of a Flow Injection Analysis Fourier Transform Mass Spectrometry (FIA-FTMS) Method to Quantify Lipid Species Profiles of Biological Samples / Marcus Höring ; Betreuer: Gerhard Liebisch." Regensburg : Universitätsbibliothek Regensburg, 2020. http://d-nb.info/1209738163/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

CRUZ, ROSANA PETINATTI DA. "DEVELOPMENT OF A METHODOLOGY FOR CORALS AND SPELEOTHEMS DATING USING THE 230-TH/234-U METHOD, THROUGH CHROMATOGRAPHIC SEPARATION AND QUANTIFICATION BY ALPHA SPECTROMETRY AND FIA-ICP-MS." PONTIFÍCIA UNIVERSIDADE CATÓLICA DO RIO DE JANEIRO, 2006. http://www.maxwell.vrac.puc-rio.br/Busca_etds.php?strSecao=resultado&nrSeq=8544@1.

Full text
Abstract:
CONSELHO NACIONAL DE DESENVOLVIMENTO CIENTÍFICO E TECNOLÓGICO<br>O presente trabalho aborda as determinações de idades de espeleotemas e corais, usando o método de desequilíbrio da série urânio, mais especificamente, o método de deficiência de filhos daughter deficient DD, em particular o método 230Th/234U. Foram testadas diferentes metodologias empregando separação por extração cromatográfica e quantificação por espectrometria alfa e ICP-MS. Foram testados três procedimentos diferentes: separação em batelada empregando-se colunas com Tri-octil óxido de fosfina (TOPO) em silica- gel
APA, Harvard, Vancouver, ISO, and other styles
5

Ertl, Verena [Verfasser], and Gerhard [Akademischer Betreuer] Liebisch. "Development and Application of a High-Resolution Flow Injection Analysis Fourier Transform Mass Spectrometry (FIA-FTMS) Method to Identify and Quantify Lipids in Human Fecal Samples / Verena Ertl ; Betreuer: Gerhard Liebisch." Regensburg : Universitätsbibliothek Regensburg, 2021. http://d-nb.info/1231076151/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Li, Dongfang. "Development of immunoassay screening methods using long wavelength fluorescence." Thesis, Loughborough University, 2004. https://dspace.lboro.ac.uk/2134/12905.

Full text
Abstract:
The developments of immunoassay methods for the early stage diagnosis of tuberculosis (TB) are described. These went through two different routes, one through flow injection analysis (FIA), and the other using immunochromatography methodology. The design of a simple longwavelength fluorescence detector to serve the above purposes has also been described. The FIA immunoassay methods involve immobilising antibodies on to beads, either directly or through protein A based solid phases. The beads are then packed into a micro-column reactor for incorporation into the FIA system. In this case reactor
APA, Harvard, Vancouver, ISO, and other styles
7

Maan, Franz Sanderson. "Extension and development of the fixed grid FEA method." Thesis, University of Leeds, 2008. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.511135.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Weerakoon, Prasad. "Multi-User Methods for FEA Pre-Processing." BYU ScholarsArchive, 2012. https://scholarsarchive.byu.edu/etd/3255.

Full text
Abstract:
Collaboration in engineering product development leads to shorter product development times and better products. In product development, considerable time is spent preparing the CAD model or assembly for Finite Element Analysis (FEA). In general Computer-Aided Applications (CAx) such as FEA deter collaboration because they allow only a single user to check out and make changes to the model at a given time. Though most of these software applications come with some collaborative tools, they are limited to simple tasks such as screen sharing and instant messaging. This thesis discusses methods to
APA, Harvard, Vancouver, ISO, and other styles
9

Elgström, Eskil. "Practical implementation of hyperelastic material methods in FEA models." Thesis, Blekinge Tekniska Högskola, Institutionen för maskinteknik, 2014. http://urn.kb.se/resolve?urn=urn:nbn:se:bth-5654.

Full text
Abstract:
This thesis will be focusing on studies about the hyperelastic material method and how to best implement it in a FEA model. It will look more specific at the Mooney-Rivlin method, but also have a shorter explanation about the different methods. This is due to problems Roxtec has today about simulating rubber takes long time, are instable and unfortunately not completely trustworthy, therefore a deep study about the hyperelastic material method were chosen to try and address these issuers. The Mooney-Rivlin method (which is a part of the hyperelastic material method) is reliant on a few constan
APA, Harvard, Vancouver, ISO, and other styles
10

Bessems, Petrus Johannes Maria Joannes. "The cryosurgical open-cone-spray method." [Maastricht : Maastricht : Rijksuniversiteit Limburg] ; University Library, Maastricht University [Host], 1989. http://arno.unimaas.nl/show.cgi?fid=5517.

Full text
APA, Harvard, Vancouver, ISO, and other styles
More sources

Books on the topic "FIA method"

1

Paul, Bill. FEA made easy with pro/mechanica. OnWord Press, 1997.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
2

Porter, Michael A. FEA step by step with Algor. Dynamic Analysis, 1993.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
3

Cottrell, J. Austin. Isogeometric analysis: Toward integration of CAD and FEA. J. Wiley, 2009.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
4

Liang, Huixing. Cai pan de fang fa: Method of judgement. Fa lü chu ban she, 2003.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
5

Point estimation of root finding methods. Springer, 2008.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
6

Maritz, J. S. Distribution-free statistical methods. 2nd ed. Chapman & Hall, 1995.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
7

McElroy, Frank F. A cryogenic preconcentration: Direct FID (PDFID) method for measurement of NMOC in ambient air. U.S. Environmental Protection Agency, Environmental Monitoring Systems Laboratory, 1986.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
8

Meijer, Rob R. Exploring new methods to detect person misfit in CAT. Law School Admission Council, 2006.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
9

Edminster, Carleton B. A method for constructing site index curves from height-age measurements applied to Douglas-fir in the Southwest. USDA, Forest Service, Rocky Mountain Forest and Range Experiment Station, 1991.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
10

Meijer, Rob R. Some new methods to detect person fit in CAT. Law School Admission Council, 1999.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
More sources

Book chapters on the topic "FIA method"

1

Carbonell Y José, José V., and José Ma Sendra. "Development of a Fluorimetric-Fia Method to Monitor Cyclodextrin Production from Starch and the Formation of Inclusion Complexes." In Proceedings of the Ninth International Symposium on Cyclodextrins. Springer Netherlands, 1999. http://dx.doi.org/10.1007/978-94-011-4681-4_1.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Hof, A. "Uniform distribution and the projection method." In Quasicrystals and Discrete Geometry. American Mathematical Society, 1998. http://dx.doi.org/10.1090/fim/010/07.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Bottcher, Albrecht. "Infinite matrices and projection methods." In Fields Institute Monographs. American Mathematical Society, 1995. http://dx.doi.org/10.1090/fim/003/01.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Pilz, Matthias. "Introduction: Questions, Challenges and Methods." In Fit for Business. VS Verlag für Sozialwissenschaften, 2012. http://dx.doi.org/10.1007/978-3-531-19028-0_1.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Yoshioka, Keita, Mathias Nest, Daniel Pötschke, Amir Shoarian Sattari, Patrick Schmidt, and David Krach. "Numerical Platform." In GeomInt–Mechanical Integrity of Host Rocks. Springer International Publishing, 2021. http://dx.doi.org/10.1007/978-3-030-61909-1_3.

Full text
Abstract:
AbstractAn essential scientific goal of the GeomInt project is the analysis of potentials and limitations of different numerical approaches for the modelling of discontinuities in the rocks under consideration in order to improve the understanding of methods and their synergies with regard to theoretical and numerical fundamentals. As numerical methods, the “Lattice Element Method” (LEM), the non-continuous discontinuum methods “Discrete Element Method” (DEM), the “Smoothed Particle Hydrodynamics” (SPH), the “Forces on Fracture Surfaces” (FFS) as well as the continuum approaches “Phase-Field Method” (PFM), “Lower-Interface-Method” (LIE), “Non-Local Deformation” (NLD) and the “Hybrid-Dimensional Finite-Element-Method” (HDF) will be systematically investigated and appropriately extended based on experimental results (Fig. 3.1).
APA, Harvard, Vancouver, ISO, and other styles
6

Hutterer, Rudi. "Nucleinsäuren, Genexpression und molekularbiologische Methoden." In Fit in Biochemie. Vieweg+Teubner, 2010. http://dx.doi.org/10.1007/978-3-8348-9379-6_5.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Battista, Tonio Di, Stefano A. Gattone, and Angela De Sanctis. "Dealing with FDA Estimation Methods." In Studies in Classification, Data Analysis, and Knowledge Organization. Springer Berlin Heidelberg, 2011. http://dx.doi.org/10.1007/978-3-642-11363-5_40.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Gordon, Marc. "Salvaging Strasberg at the Fin De Siècle." In Method Acting Reconsidered. Palgrave Macmillan US, 2000. http://dx.doi.org/10.1007/978-1-349-62271-9_2.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Hutterer, Rudi. "Lösungen – Nucleinsäuren, Genexpression und molekularbiologische Methoden." In Fit in Biochemie. Vieweg+Teubner, 2010. http://dx.doi.org/10.1007/978-3-8348-9379-6_12.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Kizilyaprak, Caroline, Anne Greet Bittermann, Jean Daraspe, and Bruno M. Humbel. "FIB-SEM Tomography in Biology." In Methods in Molecular Biology. Humana Press, 2013. http://dx.doi.org/10.1007/978-1-62703-776-1_24.

Full text
APA, Harvard, Vancouver, ISO, and other styles

Conference papers on the topic "FIA method"

1

Zhu, Guoqiang, Siyuan He, Jingjing He, and Wu Xuezhi. "Study of a 3DMLUV-FIA method for EM scattering from dielectric object and rough surface." In 2016 IEEE-APS Topical Conference on Antennas and Propagation in Wireless Communications (APWC. IEEE, 2016. http://dx.doi.org/10.1109/apwc.2016.7738136.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Kato, H., K. Uchida, Y. Okada, and T. Yamaguchi. "ANALYSIS OF HYPERCOAGULABILITY BY AUTOMATED FLUOROGENIC METHODS." In XIth International Congress on Thrombosis and Haemostasis. Schattauer GmbH, 1987. http://dx.doi.org/10.1055/s-0038-1643053.

Full text
Abstract:
In order to detect hypercoagulable state due to the increase or decrease of coagulation factors and inhibitors concentrations or the presence of active coagulation factors or tissue factor in plasma, highly sensitive automated methods were developed using fluorogenic substrate for thrombin. Coagulability of human plasma was measured by mixing 3 yl of plasma with Thromborel S (TF), calcium and Boc-Val-Pro-Arg-MCA(MCA) (Fluorogenic PT, FPT). FPT of normal plasma was shortened by the addition of purified X or VII (Final conc. 1-5 U per ml), and of thrombin (0.3-1 ng) or Xa (10500 pg). Factors VII
APA, Harvard, Vancouver, ISO, and other styles
3

Wang, Zhanghai, Daryl Bast, and David Shen. "Butane Storage Bullet Calculation and FEA Verification." In ASME 2005 Pressure Vessels and Piping Conference. ASMEDC, 2005. http://dx.doi.org/10.1115/pvp2005-71123.

Full text
Abstract:
This paper presents a comparative study of FEA with the Zick’s method of analysis for a two saddles-supported horizontal cylindrical tank. Zick’s method is an analytical method commonly used in horizontal vessel support design. We used two methods to calculate local stresses in selected areas with the findings that the results of these two methods produced very agreement. These results are used to verify the FEA for this application. We then used FEA to get more detailed information about stress distribution, which cannot be obtained using the Zick’s method. FEA was further used to study the b
APA, Harvard, Vancouver, ISO, and other styles
4

Cao, Hanqiang, Yaoting Zhu, Guang-Xi Zhu, and Zhengbing Zhang. "Novel edge detection method using FIC scheme." In International Symposium on Multispectral Image Processing, edited by Ji Zhou, Anil K. Jain, Tianxu Zhang, Yaoting Zhu, Mingyue Ding, and Jianguo Liu. SPIE, 1998. http://dx.doi.org/10.1117/12.323589.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Reddy, T. H., K. Karibasappa, and A. Damodaram. "Face detection using modified FDA-SVM method." In National Conference on Signal and Image Processing Applications. IET, 2009. http://dx.doi.org/10.1049/ic.2009.0169.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Silverman, S., R. Aucoin, J. Mallatt, and D. Ehrlich. "Laser Microchemical Technology: New Tools for Flip-Chip Debug and Failure Analysis." In ISTFA 1997. ASM International, 1997. http://dx.doi.org/10.31399/asm.cp.istfa1997p0211.

Full text
Abstract:
Abstract Laser microchemical (LMC) technology has become an important element of the FIA and debug tool set by supplying key steps not well addressed by previous tools. In this paper we report the optimization of the LMC technology to solve key issues for flip chip FIA. Specific processes have been developed for localized thinning of flip chips, in order to enable access of conventional FIA tools. Additional applications include dramatic enhancement of focused ion beam (FIB) rework and 3-D micromachining for prototyping, in-situ trimming, and mastering of microelectromechanical systems (MEMS).
APA, Harvard, Vancouver, ISO, and other styles
7

Leidlich, Jonathan, Peter Robl, and Julien Raphael Mrowka. "Methoden für die durchgängige Anwendung einer EBOM mithilfe klassenbasierter Substitutionsobjekte." In Entwerfen Entwickeln Erleben - EEE2021. Prof. Dr.-Ing. habil Ralph H. Stelzer, Prof. Dr.-Ing. Jens Krzywinski, 2021. http://dx.doi.org/10.25368/2021.27.

Full text
Abstract:
Innerhalb der Initiative zur vierten industriellen Revolution, bei der Menschen, Produkt und Maschine in Echtzeit vernetzt sind, geht der Trend weg von der Serienfertigung und hin zur „Losgröße 1“. Die ansteigende Anzahl an Varianten bringt jedoch auch höhere Verwaltungsaufwände mit sich. Um dem entgegenzuwirken wird die Methode der funktional substituierbaren Bauteile eingeführt. Diese ermöglicht die Verwaltung von technisch substituierbaren Komponenten innerhalb der Stücklisten einer konkreten Variante. Durch die Integration der Methoden FIM (Functional-Information-Model) und FIA (Functional
APA, Harvard, Vancouver, ISO, and other styles
8

WADA, M., M. KATOH, H. KIDO, MN NAKASHIMA, N. KURODA, and K. NAKASHIMA. "DEVELOPMENT OF FIA-CHEMILUMINESCENCE METHODS TO EVALUATE QUENCHING EFFECTS AGAINST REACTIVE OXYGEN SPECIES." In Proceedings of the 13th International Symposium. WORLD SCIENTIFIC, 2005. http://dx.doi.org/10.1142/9789812702203_0084.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Liew Kaeng Nan, Lee Meng Lung, and Chen Tung Hung. "FIB tilting method for thin TEM lamella preparation." In 2015 IEEE 22nd International Symposium on the Physical and Failure Analysis of Integrated Circuits (IPFA). IEEE, 2015. http://dx.doi.org/10.1109/ipfa.2015.7224349.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Chen, Hao, Rongfeng Li, Lingyan Dai, and Yinbo Shao. "A Nonlinear FDA Optimal Frequency Increment Selection Method." In 2018 IEEE 3rd International Conference on Signal and Image Processing (ICSIP). IEEE, 2018. http://dx.doi.org/10.1109/siprocess.2018.8600493.

Full text
APA, Harvard, Vancouver, ISO, and other styles

Reports on the topic "FIA method"

1

Moore, Frank G., Roy M. McInville, and David I. Robinson. A Simplified Method for Predicting Aerodynamics of Multi-Fin Weapons. Defense Technical Information Center, 1999. http://dx.doi.org/10.21236/ada361829.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Kirac, Ahmet, and P. P. Vaidyanathan. FIR Compaction Filters: New Design Methods and Properties,. Defense Technical Information Center, 1997. http://dx.doi.org/10.21236/ada324480.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Kirac, Ahmet, and P. P. Vaidyanathan. Efficient Design Methods of Optimal FIR Compaction Filters for M-channel FIR Subband Coders,. Defense Technical Information Center, 1996. http://dx.doi.org/10.21236/ada327786.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Hoy, James B., and Michael I. Haverty. Pest management in Douglas-fir seed orchards: a microcomputer decision method. U.S. Department of Agriculture, Forest Service, Pacific Southwest Forest and Range Experiment Station, 1988. http://dx.doi.org/10.2737/psw-gtr-108.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Lau, Flora, Winnie Yu, Jintu Fan, and Rong Zheng. New Methods for the Objective Measurement of Bra Fit. Iowa State University, Digital Repository, 2013. http://dx.doi.org/10.31274/itaa_proceedings-180814-463.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Schreuder, H. T., and M. S. Williams. Reliability of confidence intervals calculated by bootstrap and classical methods using the FIA 1-ha plot design. U.S. Department of Agriculture, Forest Service, Rocky Mountain Research Station, 2000. http://dx.doi.org/10.2737/rmrs-gtr-57.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Andraka, C. E., G. A. Knorovsky, and C. A. Drewien. Boundary element method applied to a gas-fired pin-fin-enhanced heat pipe. Office of Scientific and Technical Information (OSTI), 1998. http://dx.doi.org/10.2172/672137.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Bostelman, Roger, Ya-Shian Li-Baboud, Karl Van Wyk, and Mili Shah. Development of a Kinematic Measurement Method for Knee Exoskeleton Fit to a User. National Institute of Standards and Technology, 2020. http://dx.doi.org/10.6028/nist.tn.2107.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Donati, F. Marchesi, and M. A. Kedzierski. A simple prediction method for condensation heat transfer inside a micro-fin tube. National Institute of Standards and Technology, 1999. http://dx.doi.org/10.6028/nist.ir.6417.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Sloop Jr, Frederick {Fred} V. A GC-FID-Based Method for Quantifying the Breakdown of TiDG in NGS Solvent. Office of Scientific and Technical Information (OSTI), 2018. http://dx.doi.org/10.2172/1491325.

Full text
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!